to U-602075 LS-92-015 Page 6 of 7 3/4.7 PLANT SYSTEMS 3/4.7.1 SERVICE WATER SYSTEHS SHUTDOWN SERVICE WATER SYSTEM (LOOPS A, 8, C)
LIMITING CONDITION FOR OPERATION 3.7.1.1 The shutdown service water (SX) loop (s) shall be OPERABLE during times when its associated system (s) or components are required to be OPERABLE.
Each OPERABLE SX loop shall be comprised of:
a.
An OPERABLE flow path capable of taking suction from ultimate heat sink and transferring water through the associated system (s) and components that are required to be OPERABLE.
APPLICABILITY: OPERATIONAL CONDITIONS 1, 2, 3, 4, 5, and *.
ACTION:
Vith a shutdown service water loop (s) inoperable and with its associated sys-tem (s) or component (s) required to be OPERABLE, declare the associated system (s) or component (s) inoperable and take the ACTION required by Specification (s) 3.4.9.1, 3.[4245J.s3.5.263414J.8JJ.4Q1JgdJ41120s 3 lienble.
3,oA cwc_ not c4pp%etace h ppli, gab M{9 dIu2RE S N h o
S ec,Q c.acco The p<w w'.ce a
one. rectu' ired
{PE.R6TicNAL. CctJD TicQ LI er 5 w aw er ervk nb MY/EI? tac 4.7.1.1 The above required shutdown service water system loops shall be demonstrated OPERABLE:
At least once per 31 days by verifying that each valve in the flow path a.
that is not locked, sealed or otherwise secured in position, is in its correct position, At least once per 18 months during shutdown by verifying that each auto-b.
matic valve servicing safety related and non-safety related equipment actuates to the correct position and that each shutdown service water pump starts on a LOCA test signal.
9212210288 921215 PDR ADOCK 05000461 P
PDR "Vnen handling irradiated fuel in the Fue1 Handling Building or primary containment.
CLINTON - UNIT 1 3/4 7-1 me-we w
u-v-r--r%wmiy,--
y-g-y 7'
=---v-y y
-++py
-v e-e--
l l
to 0-602075 LS-92-015 j
Page 7 of 7 i
i PLANT SYSTEM 5 3/4.7.2 CONTROL ROOM VENTILATION SYSTEM LIMITING CONDITION FOR OPERATION 3.7.2 Two independent Control Room Ventilation Systems shall be OPERABLE.t APPLICABILITY: All OPERATIONAL CONDITIONS and *.
ACTION:
In OPERATIONAL CONDITION 1, 2 or 3 with one Control Room Ventilation System inoperable, restore the inoperable system to OPERABLE status within a.
7 days or be in at least HOT SHUTDOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and in COLD SHVIDOWH within the following 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.
b.
In OPERATIONAL CONDITION 4, 5, or *:
With one Control Room Ventilation System inoperable, restore the 1.
inoperable system to OPERABLE status within 7 days or initiate and maintain o ratioAqLtjia,,0PERASL(systentjp_thejl gtt radi ion mode i
N EM h% 6.M cire r
,4Lopergt DheproMense5 cnwy nk) CPERATicNhL CcNamou 4 ce5.
i Q pp % bit r
WilfElioth-C6titVoiloo~m'Ve~n'tflition~TiiGini'fhojieTabTir~stisjiend CORE 2.
ALTERATIONS, handling of irradiated fuel in the secondary containment and operationr with a potential for draining the reactor vessel.
The provisions of Specification 3.0.3 are not applicable in OPERATIONAL c.
CONDITION ".
T SURVEILLANCE REQUIREMENTS 4.7.2 Each Control Room Ventilation System shall be demonstrated OPERABLE:t At least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> by verifying that-the control room air tempera-l a.
ture is less than or equal to 86*F.
l At least once per 31 days on a STAGGERED TEST BASIS by initiating, from
'b.
the control room, flow through the HEPA filters and charcoal adsorbers and verifying that the makeup filter system operates continuously for at least 10 hours1.157407e-4 days <br />0.00278 hours <br />1.653439e-5 weeks <br />3.805e-6 months <br /> with the heaters operating; and with flow through the recircula-tion charcoal adsorber for at least 15 minutes.
- When irradiated fuel is being handled in the secondary containment.
tAutomatic transfer to the chlorine mode is not required when chlorine containers-having a capacity of 150 pounds or less are stored 100 meters or more from the control room or its fresh air inlets.
1 i
CLINTON - UNIT 1 3/4 7-3
.