Amend 184 to License DPR-16,changing TS 3.1-5 & 3.1-16 to Indicate 40 Percent of Rated Reactor Thermal Power as Anticipatory Reactor Scram Bypass Setpoint on Turbine Trip or Generator Load Rejection
ML20117K531
Person / Time
Site: Oyster Creek
(DPR-016)
Issue date: 06/04/1996
From: Stolz J
Office of Nuclear Reactor Regulation
To:
GPU Nuclear Corp, Jersey Central Power & Light Co
Shared Package
ML20117K533 List:
References
DPR-16-A-184 NUDOCS 9606110345
Download: ML20117K531 (5)


Text

yy s'

p reto p

4 UNITED STATES i

NUCLEAR REGULATORY COMMISSION t

\\.....J WASHINGTON, D.C. 20066-0001 GPU NUCLEAR CORPORATION AND JERSEY CENTRAL POWER & LIGHT COMPANY DOCKET NO. 50-219 l

OYSTER CREEK NUCLEAR GENERATING STATION

(

l AMENDMENT TO FACILITY OPERATING LICENSE l

l Amendment No.184 License No. DPR-16 1.

The Nuclear Regulatory Commission (the Comission) has found that:

A.

The application for amendment by GPU Nuclear Corporation, et al.

(the licensee) dated March 28, 1996, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Comission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the~

provisions of the Act, and the rules and regulations of the Comission; C.

There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Comission's regulations; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

9606110345 960604 PDR ADOCK 05000219 P

PDR

k" i

2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. DPR-16 is hereby amended to read as follows:

i (2)

Technical Snecifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No.184, are hereby incorporated in the license.

GPU Nuclear Corporation shall operate the facility in accordance with the Technical Specifications.

3.

This license amendment is effective as of the date of issuance, to be implemented within 30 days of issuance.

FOR THE NUCLEAR REGULATORY COMISSION I

^

^

(do n7. Stolz, Director Py6 ject Directorate I-Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation

Attachment:

Changes to the Technical Specifications Date of Issuance: June 4, 1996 l

1

~ -'7$:

j ATTACMENT TO LICENSE AMENDMENT NO.184 i

FACILITY OPERATING LICENSE NO. DPR-16 DOCKET NO. 50-219 Replace the following pages of the Appendix A, Technical Specifications, with the attached pages as indicated. The revised pages are identified by 4

j amendment number and contain vertical lines indicating the areas of change.

l 4

Remove Insert 3.1-5 3.1-5 3.1-16 3.1-16 e

l e

4 s

i 4

j 4

l i

e i

=

~ *

?

rs High drywell pressure provides a second means of initiating the core spray to mitigate the consequences of loss-of-coolant accident, its trip setting of.5;.3.5 psig initiates the core spray l

in time to provide adequate core cooling. The break size coverage of high drywell pressure was discussed above. Low-low water h, vel and high drywell pressure in addition to initiating core a

spray also causes isolation valve closure. These settings are adequate to cause isolation to minimize the offsite dose within required limits.

I It is permissible to make the drywell pressure instrument channels inoperable during performance of the integrated primary containment leakage rate test provided the reactar is in the COLD l

SHUTDOWN condition. The reason for this is that the Engineered Safety l

Features, which are effective in case of a LOCA under these conditions, will still be effective because they will be activated (when the Engineered Safety Features system is required as identified in the technical specification of the system) by low-low reactor water level.*

1 1

The scram discharge volume has two separate instrument volumes utilized to detect water j

accumulation. The high water level is based on the design that the water in the SDIV's, as J

detected by either set of level instruments, shall not be allowed to exceed 29.0 gallons; thereby, j

permitting 137 control rods to scram. To provide further margin, an accumulation of not more i

than 14.0 gallons of water, as detected by either instrument volume, will result in a rod block and an alarm. The accumulation of not more than 7.0 gallons of water, as detected in either j

instrument volume will result in an alarm.

}

Detailed analyses of transients have shown that sufficient protection is provided by other scrams j

below 45% power to permit bypassing of the turbine trip and generator load rejection scrams.

i However, for operational convenience,40% of rated reactor thermal power has been chosen as l

4 the serpoint below which these trips are bypassed. This setpoint is coincident with bypass valve l

capeity.

i A low condenser vacuum scram trip of 20 inches Hg has been provided to protect the main condenser in the event that vacuum is lost. A loss of condenser vacuum would cause the turbine j

stop valves to close, resulting in a turbir.e trip transient.

The low condenser vacuum trip provides a reliable backup to the turbine trip. Thus, if there is a failure of the turbine trip on low vacuum, the reactor would automatically scram at 20 inches Hg. The condenser is capable of receiving bypass steam until 7 inches Hg vacuum thereby mitigating the transient and providing a margin.

The settings to isolate the isolation condenser in the event of a break in the steam or condensate lines are based on the predicted maximum flows that these systems would experience during operation, thus permitting operation while affording protection in the event of a break. The settings correspond to a flow rate of less than three times the normal flow rate of 3.2X105 lb/hr.

Upon initiation of the alternate shutdown panel, this function is bypassed to prevent spurious isolation due to fire induced circuit faults. -

OYSTER CREEK 3.1-5 Amendment No.:-73, M,-142,449:+74,+% 184

  • Correction 11/30/87

M

~

TABLE 3.1.1 (CONT'D)

Action required when minimum conditions for operation are not satisfied.

Also permissible to trip inoperable trip system. A channel may be placed in an inoperable status for up to six hours for required surveillance without placing the trip system in the tripped condition provided at least one OPERABLE instrument channel in the same trip system is monitoring that parameter.

See Specification 2.3 for Limiting Safety System Settings.

Notes:

a.

Permissible to bypass. with control rod block, for reactor protection system reset in REFUEL MODE.

b.

Permissible to bypass below 800 psia in REFUEL and STARTUP MODES, One (1) APRM in each OPERABLE trip system may be bypassed or inoperable provided c.

the requirements of Specification 3.1.C and 3.10.C are satisfied. Two APRM's in the same quadrant shall not be concurrently bypassed except as noted below or permitted by note.

Any one APRM may be removed from service for up to six hours for test or calibration without inserting trips in its trip system only if the remaining OPERABLE APRM's meet the requirements of Specification 3.1.B.1 and no control rods are moved outward during the calibration or test. During this short period. the requirements of Specifications 3.1.B.2,3.1.C and 3.10.C need not be met.

d.

The IRMs shall be inserted and OPERABLE until the APRMs are OPERABLE and reading at least 2/150 full scale.

Offgas system isolation trip set at.12.1/E Ciisec where E = average gamma energy from e.

noble gas in offgas after holdup line (Mev). Air ejector isolation valve closure time delay shall not exceec 15 minutes.

f.

Unless SRM chambers are fully inserted.

g.

Not cpplicable when IRM on lowest range.

l h.

One instrument channel in each trip system may be inoperable provided the circuit which it operates in the trip system is placed in a simulated tripped condition. If repairs cannot -

be completed within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> the reactor shall be PLACED IN THE COLD SHUTDOWN

{

CONDITION.

If more than one instrument channel in any trip system becomes i

inoperable, the reactor shall be PLACED IN THE COLD SHUTDOWN CONDITION.

1 Relief valve controllers shall not be bypassed for more than 3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br /> (total time for all controllers) in any 30-day period and only one relief valve controller may be bypassed at i

a time.

l i.

The interlock is not required during the start-up test program and demonstration of plant electrical output but shall be provided following these actions.

J.

Not required below 40% of rated reactor thermal power.