t ENCLOSURE 1 TO SERIAL: NLS-85-152 REVISED BRUNSWICK-1 AND BRUNSWICK-2 TECHNICAL SPECIFICATION PAGES
$50$0$24 A
(1431 MAT /ccc)
(BSEP-1-19) 3/4.6 CONTAINMENT SYSTEMS 3/4.6.1 PRIMARY CONTAINMENT PRIMARY CONTAINMENT INTEGRITY LIMITING CONDITION FOR OPERATION 3.6.1.1 PRIMARY CONTAINMENT INTEGRITY shall be maintained.
f APPLICABILITY: CONDITIONS 1, 2, and 3.
ACTION:
Without PRIMARY CONTAINMENT INTEGRITY, restore PRIMARY CONTAINMENT INTEGRITY within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> or be in at least HOT SHUTDOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and in COLD SHUTDOWN within the following 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.
SURVEILLANCE REQUIREMENTS 4.6.1.1 PRIMARY CONTAINMENT INTEGRITY shall be demonstrated:
3 At least oneg per 31 days by verifying that all primary containment a.
penetrations not capable of being closed by OPERABLE containment automatic isolation valves and required to be closed during accident conditions are closed by valves, blind flanges, or deactivated automatic valves secured in position, except as provided in Table 3.6.3-1 or Specification 3.6.3.
b.
By verifying each primary containment air lock OPERABLE per l
Specification 3.6.1.3.
c.
By verifying the suppression pool OPERABLE per Specification 3.6.2.1.
i l
l l
I l
- Except valves, blind flanges, and deactivated automatic valves which are located inside the containment, the MSIV Pit, the RWCU Room, or the TIP Room, and are locked, sealed,.or otherwise secured in the closed position.
These penetrations shall be verified closed during each COLD SHUTDOWN l
except such verification need not be performed.when the primary containment has not been de-inerted since the last verification or more often than once per 92 days.- Those valves located above the drywell head requiring head shield block removal for verification will be verified prior to each replacement of:the shield blocks.
BRUNSWICK - UNIT 1 3/4 6-1 Amendment No.
s
(BSEP-2-19) 3/4.6 CONTAINMENT SYSTEMS 3/4.6.1 PRIMARY CONTAINMENT PRIMARY CONTAINMENT INTECRITY LIMITING CONDITION FOR OPERATION 3.6.1.1 PRIMARY CONTAINMENT INTEGRITY shall be maintained.
l APPLICABILITY: CONDITIONS 1, 2, and 3.
ACTION:
Without PRIMARY CONTAINMENT INTEGRITY, restore PRIMARY CONTAINMENT INTEGRITY within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> or be in at least HOT SHUTDOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and in COLD SHUTDOWN within the following 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.
SURVEILLANCE REQUIREMENTS 4.6.1.1 PRIMARY CONTAINMENT INTEGRITY shall be demonstrated:
At least oncg per 31 days by verifying that all primary containment a.
penetrations not capable of being closed by OPERABLE containment automatic isolation valves and required to be closed during accident conditions are closed by valves, blind flanges, or deactivated automatic valves secured in position, except as provided in Table 3.6.3-1 or Specification 3.6.3.
b.
By verifying each primary containment air lock OPERABLE per l
Specification 3.6.1.3.
c.
By verifying the suppression pool OPERABLE per Specification 3.6.2.1.
- Except valves, blind flanges, and deactivated automatic valves which are located inside the containment, the MSIV Pit, the RWCU Room, or the TIP Room, and are locked, sealed, or otherwise secured in the closed position.
These penetrations shall be verified closed during each COLD SHUTDOWN except such verification need not be performed when the primary containment has not been de-inerted since the last verification or more often than once per 92 days. Those valves located above the drywell head requiring head shield block removal for verification will be verified prior to each replacement of the shield blocks.
BRUNSWICK - UNIT 2 3/4 6-1 Amendment No.
.