DESIGN FEATURES 5.5 METEOROLOGICAL TOWER LOCATION 5.5.1 The meteorological tower shall be located as shown on Figure 5.1.2-1.

5.6 FUEL STORAGE CRITICALITY 5.6.1 The spent fuel storage racks are designed and shall be maintained with:

A k,ff equivalent to less than or equal to 0.95 when flooded with a.

unborated water, including all calculational uncertainties and biases as described in Section 4.3 of the FSAR.

6.26 b.

A nominal-Mvinch center-to-center distance between fuel assemblies placed in the storage racks.

5.6.1.2 The k,ff for new fuel for the first core loading stored dry in the spent fuel storage racks shall not exceed 0.98 when aqueous foam moderation is assumed.

DRAINAGE 5.6.2 The spent fuel storage pool is designed and shall be maintained to prevent inadve'rtent draining of the pool below elevation 202'5 1/4".

CAPACITY C4 AdC 8D 5.6.3 The spent fuel storage-peep'is designed and shall be :: int:in:d with :

tcr:;;; ::p::!ty limited to::: : re th:n 1270 S:1
,ublic,.

N 5.7 COMPONENT CYCLIC OR TRANSIENT LIMIT l'

5.7.1 The components identified in Table 5.7.1-1 are designed and shall be maintained within the cyclic or transient limits of Table 5.7.1-1.

a. no moys-sk.n 4352 kl assemblie.s in the spe><t hel pool, b.No more. t Aa.n goo M assemblies h de upfo conk.',uunf p**/.

8505090375 850506 PDR ADOCK 05000416

(

P PDR GRAND GULF-UNIT 1 5-6 AnulAeN6 Mo.