Other: AECM-85-0289, Forwards Revised Proposed Tech Spec Change Concerning Spent Fuel Pool & Upper Containment Pool Storage Capacity After Installation of High Density Spent Fuel Racks,Per 850506 Submittal, AECM-85-0297, Forwards Correction to Table 1 of 850815 Final Response to NRC Question Re Dynamic Analysis of High Density Spent Fuel Racks Proposed for Installation at Facility, AECM-85-0352, Forwards Clarification of Use of Stress Criteria for High Density Spent Fuel Racks,In Response to NRC Request.Stress Criteria Differences Between OT Position Paper & NUREG-0800 Amount to Same Limits for Rack Modules, AECM-86-0077, Forwards Revised Spent Fuel Loading Pattern Developed to Maintain Dose Rate Contribution from Spent Fuel in Auxiliary Bldg Spent Fuel Pool Area Below 2.5 Mrems/H for Routinely Accessible Areas, AECM-86-0179, Forwards Revised Tech Spec Page 5-6 Inadvertently Omitted from 860605 Submittal Re High Density Spent Fuel Racks, AECM-86-0229, Forwards Responses to NRC Concerns Re Spent Fuel Decay Heat Capability & Associated Operating Procedures,Per 860716 Telcon.Requests That OL Amend for High Density Racks Be Granted on 860818, ML20117C275, ML20117C283, ML20205D440, ML20205T067 | |
From | |
MONTHYEARML20117C2831985-05-0606 May 1985
[table view]Licensing Rept,High-Density Spent Fuel Racks AECM-85-0143, Forwards Application for Amend to License NPF-29,changing Tech Specs to Allow Replacement of low-density Aluminum Spent Fuel Racks w/high-density Spent Fuel Racks. Licensing Rept,High-Density Spent Fuel Racks, Encl.Fee Paid1985-05-0606 May 1985 Forwards Application for Amend to License NPF-29,changing Tech Specs to Allow Replacement of low-density Aluminum Spent Fuel Racks w/high-density Spent Fuel Racks. Licensing Rept,High-Density Spent Fuel Racks, Encl.Fee Paid ML20117C2611985-05-0606 May 1985 Application for Amend to License NPF-29,changing Tech Specs to Allow Replacement of Current low-density Aluminum Spent Fuel Racks w/high-density Spent Fuel Racks to Provide Increased Storage Capacity ML20117C2751985-05-0606 May 1985 Proposed Tech Specs Allowing Replacement of Current low-density Aluminum Spent Fuel Racks w/high-density Spent Fuel Racks to Provide Increased Storage Capacity ML20129F9581985-07-0505 July 1985 Forwards Request for Addl Info Re High Density Spent Fuel Racks in Upper Containment Pool & in Spent Fuel Storage Pool.Response Due by 850715 ML20133A1781985-07-26026 July 1985 Forwards Request for Addl Info Re Application to Amend License NPF-29,allowing Installation of High Density Spent Fuel Racks in Upper Containment Pool & Spent Fuel Storage Pool.Info Requested by 850815 AECM-85-0229, Responds to 850705 Request for Addl Info Re Structural Analyses Presented in 850506 Application for Amend to License NPF-29,allowing Installation of High Density Spent Fuel Racks.Direct Stress Below Liner Matl Ultimate Stress1985-07-29029 July 1985 Responds to 850705 Request for Addl Info Re Structural Analyses Presented in 850506 Application for Amend to License NPF-29,allowing Installation of High Density Spent Fuel Racks.Direct Stress Below Liner Matl Ultimate Stress ML20136H1801985-08-0909 August 1985 Forwards Request for Addl Info Re 850506 Request for Amend to License NPF-29,allowing Installation of High Density Spent Fuel Racks in Upper Containment Pool & in Spent Storage Pool.Info Requested by 850826 AECM-85-0252, Responds to NRC 850705 Request for Addl Info Re Structural Analyses Presented in Application for Amend to License NPF-29,authorizing Installation of High Density Spent Fuel Racks.Info Re Numerical Solution of Dynamic Analyses Encl1985-08-15015 August 1985 Responds to NRC 850705 Request for Addl Info Re Structural Analyses Presented in Application for Amend to License NPF-29,authorizing Installation of High Density Spent Fuel Racks.Info Re Numerical Solution of Dynamic Analyses Encl AECM-85-0272, Forwards Response to NRC 850726 Request for Addl Info Re Amend to License NPF-29,allowing Installation of High Density Spent Fuel Racks.Tech Spec Section 4.5 Changed to Conform to Ref Design Used in Analysis1985-08-30030 August 1985 Forwards Response to NRC 850726 Request for Addl Info Re Amend to License NPF-29,allowing Installation of High Density Spent Fuel Racks.Tech Spec Section 4.5 Changed to Conform to Ref Design Used in Analysis AECM-85-0297, Forwards Correction to Table 1 of 850815 Final Response to NRC Question Re Dynamic Analysis of High Density Spent Fuel Racks Proposed for Installation at Facility1985-09-11011 September 1985 Forwards Correction to Table 1 of 850815 Final Response to NRC Question Re Dynamic Analysis of High Density Spent Fuel Racks Proposed for Installation at Facility AECM-85-0289, Forwards Revised Proposed Tech Spec Change Concerning Spent Fuel Pool & Upper Containment Pool Storage Capacity After Installation of High Density Spent Fuel Racks,Per 850506 Submittal1985-09-12012 September 1985 Forwards Revised Proposed Tech Spec Change Concerning Spent Fuel Pool & Upper Containment Pool Storage Capacity After Installation of High Density Spent Fuel Racks,Per 850506 Submittal AECM-85-0352, Forwards Clarification of Use of Stress Criteria for High Density Spent Fuel Racks,In Response to NRC Request.Stress Criteria Differences Between OT Position Paper & NUREG-0800 Amount to Same Limits for Rack Modules1985-11-0101 November 1985 Forwards Clarification of Use of Stress Criteria for High Density Spent Fuel Racks,In Response to NRC Request.Stress Criteria Differences Between OT Position Paper & NUREG-0800 Amount to Same Limits for Rack Modules AECM-85-0410, Forwards Response to NRC Request to Determine & Submit Occupational Exposures Associated W/Operation W/High Density Spent Fuel Racks,Per 850506 Application for Amend to License NPF-29,allowing Installation of Racks1985-12-18018 December 1985 Forwards Response to NRC Request to Determine & Submit Occupational Exposures Associated W/Operation W/High Density Spent Fuel Racks,Per 850506 Application for Amend to License NPF-29,allowing Installation of Racks AECM-86-0077, Forwards Revised Spent Fuel Loading Pattern Developed to Maintain Dose Rate Contribution from Spent Fuel in Auxiliary Bldg Spent Fuel Pool Area Below 2.5 Mrems/H for Routinely Accessible Areas1986-03-14014 March 1986 Forwards Revised Spent Fuel Loading Pattern Developed to Maintain Dose Rate Contribution from Spent Fuel in Auxiliary Bldg Spent Fuel Pool Area Below 2.5 Mrems/H for Routinely Accessible Areas AECM-86-0011, Responds to 850809 Request for Addl Info Re 850506 Application for Amend to License NPF-29,allowing for Installation of High Density Spent Fuel Racks1986-03-15015 March 1986 Responds to 850809 Request for Addl Info Re 850506 Application for Amend to License NPF-29,allowing for Installation of High Density Spent Fuel Racks AECM-86-0176, Application for Amend to License NPF-29,changing Tech Specs 3/4.7.9.1 & 5.6.3 Re Installation of High Density Spent Fuel Racks,In Response to NRC Concerns from Review of Util .Affirmation & Justification for Change Encl1986-06-0505 June 1986 Application for Amend to License NPF-29,changing Tech Specs 3/4.7.9.1 & 5.6.3 Re Installation of High Density Spent Fuel Racks,In Response to NRC Concerns from Review of Util .Affirmation & Justification for Change Encl ML20205T3631986-06-0505 June 1986 Proposed Changes to Tech Specs 3/4.7.9.1 & 5.6.3 Re Installation of High Density Spent Fuel Racks ML20205T0671986-06-0909 June 1986 Revised Tech Spec Page 5-6 Re High Density Spent Fuel Racks AECM-86-0179, Forwards Revised Tech Spec Page 5-6 Inadvertently Omitted from 860605 Submittal Re High Density Spent Fuel Racks1986-06-0909 June 1986 Forwards Revised Tech Spec Page 5-6 Inadvertently Omitted from 860605 Submittal Re High Density Spent Fuel Racks AECM-86-0229, Forwards Responses to NRC Concerns Re Spent Fuel Decay Heat Capability & Associated Operating Procedures,Per 860716 Telcon.Requests That OL Amend for High Density Racks Be Granted on 8608181986-07-25025 July 1986 Forwards Responses to NRC Concerns Re Spent Fuel Decay Heat Capability & Associated Operating Procedures,Per 860716 Telcon.Requests That OL Amend for High Density Racks Be Granted on 860818 ML20205D4401986-07-28028 July 1986 Notice of Violation from Insp on 860613-0714 1985-08-09 |
Retrieved from "https://kanterella.com/w/index.php?title=TAC:57619&oldid=3325763"