Text
e p
4 Beaver Valley Power Station SNppingport, PA 15077 0004 M nV P esident Fax 12 64 Nuclear Power DMalon U. S. Nuclear Regulatory Commission July 18, 1996 Attention: Document Control Desk Washington, DC 20555-0001
Subject:
Beaver Valley Power Station, Unit No.1 Docket No. 50-334, License No. DPR-66 Emergency Response Data System (ERDS)
In accordance with the requirements of 10 CFR Part 50, Appendix E, Section VI.3.a and NUREG-1394, Revision 1, Section 3.6, " Administrative Implementation Requirements," the enclosed Data Point Library (DPL) changes are being subnutted.
Sixty-seven (67) DPLs will be changed. These changes will be implemented on July 22, 1996, in the Beaver Valley Power Station Unit 1 plant computer which provides data to the ERDS computer. All of the changes have been highlighted on the attached sheets.
If you have any questions concerning the DPL changes, please contact Mr. Roy K.
Brosi, Manager, Nuclear Safety Department, (412) 393-5210.
Sincerely, L
q _.
Sushil C. Jain Attachments c:
Mr. L. W. Rossbach, Sr. Resident Inspector Mr. T. T. Martin, NRC Region I Administrator g
7~
Mr. D. S. Brinkman, Sr. Project Manager 3
Mr. J. R. Jolicoeur, USNRC Incident Response Branch Mr. R. R-. Keimig, NRC Region I, Emergency Preparedness
(
Mr. P. D. Kaufman, NRC Region I, Emergency Preparedness 9607260042 960718 DEllVERING PDR ADOCK 0500 4-gyggg7y fNERGV m
S v
i BEAVER VALLEY POWER STAil0N ERDS DATA POINT LIBRARY BV1 EROS INPUT Date:
07/22/96 Reactor Unit:
BV1 Data feeder:
H2 CONC 1 Point 10:
CO201A Plant Spec Point Desc.:
CNMT HYDROGEN CONCENTRATION CH 1 Generic /Cond Desc.
CONTAINMEAT HYDROGEN CONC Analog / Digital:
A Engr Units / Dig States:
Engr Units Conversion:
LINEAR Minimum Instr Range:
0 Maximum Instr Range:
10 i
Zero Point Pefe... e:
N/A Reference roint Notes:
N/A l
PR00 or SENS:
S 1
i Number Of Sensors:
1 How Processed:
N/A Sensor Locations:
SEE UNIQUE SYSTEM DESCRIPTION FIELD Alarm / Trip Set Points:
Hi ALARM AT 1%
NI Detector Power Supply Cut off Power Level:
N/A N1 Detector Power Supply Turn on Power Level:
N/A Instrument Failure Mode:
LOW Temperature Compensation For DP Transmitters:
N Levet Reference Leg:
N/A Unique System Dese. 4 CONTAINMENT GAS IS SAMPLED AND ANALYZED AT HYDROGEN ANALYZER H2-HY101A. HYDROGEN CONCENTRATION IS INDICATED LOCALLY AND ON THE MAIN CONTROL BOAR 0. M2 HY101A SENSES HYDROGEN CONCENTRATION ALTERhATELY IN STREAM 1 YHE PRESSURIZER CUBICLE, THEN IN STREAM 2 inE SUCTION LihE FOR THE CONTAINMENT EVACUATION PUMP 1A (CONTAINMENT DOME). OP MANUAL CHAPTER 46, RM 150 1 l
l i
I
1 e
1 BEAVER VALLEY POWER STATION ERDS DATA PolNT LIBRARY BV1 ERDS INPUT i
Date:
07/22/96 i
Reactor Unit:
BV1 Data Feeder:
EXTRA 22 Point ID:
CO202A Plant Spec Point Dese.:
CNMT HYDROGEN CONCENTRATION CH 2 Generic /Cond Desc..
CONTAINMENT HYDROGEN CONC Analog /Digitat:
A Engr Units / Dig States:
Engr Units Conversion:
LINEAR j
Minimum instr Range:
0 Maximum Instr Range:
10 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
5 Number Of Sensors:
1 How Processed:
N/A Sensor Locations:
SEE UNIQUE SYSTEM DESCkiPTION FIELD Alarm / Trip Set Points:
HI ALARM AT 1%
NI Detector Power Supply Cid-of f Power Level:
N/A NI Detector Power Supply Turn-on Power Level:
N/A Instrument Failure Mode:
LOW Temperature Compensation f or DP Transmitters:
N Level Reference Leg:
N/A Unique System Desc.
CONTAINMENT GAS IS SAMPLED AND ANALYZED AT HYDROGEN ANALYZER H2-HV1018. HYDROGEN CONCENTRATION IS INDICATED LOCALLY AND ON THE MAIN CONTROL BOARD. n2-HY1018 SENSES HYDROGEN CONCENTRATION ALTERAATELY IN STREAM 1 THE PRESSURIZER CUBICLE, THEN IN STREAM 2 THE SUCTION LINE FOR THE CONTAINMENT EVACUATION PUMP 1B (CONTAINMENT DOME). OP MANUAL CHAPTER 46, RM-150-1
e s
BEAVER VALLEY PUWER STATION ERDS DATA PolNT LIBRARY BV1 EROS INPUT Date:
07/22/96 Reactor Unit:
BV1 Data Feeder:
IPC i
i NRC ERDS Parameter:
RCS ChG MU Point 10:
F0128A Plant Spec Point Desc.:
CMG PUMP DISCH HDR UNCORR FLOW Generic /Cond Desc..
PRIMARY SYSTEM CHG OR MU FLOW Analog / Digital:
A Engr Units / Dig States:
GPM Engr Units Conversion:
N/A 1
Minimum Instr Range:
0 Maximum Instr Range:
150 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
Number Of Sensors:
1 How Processed:
N/A Sensor Locations:
SEE UNIQUE SYSTEM DESCRIPil0N FIELD Alarm / Trip Set Points:
Hi ALM & 150 GPM/to ALM @ -5 GPM NI Detector Power Supply Cut-off Power Level:
N/A
)
l NI Detector Power Supply Turn-on Power Level:
N/A Instrument Failure Mode:
LOW Temperature Compensation For DP Transmitters:
h Level Ref erence Leg:
N/A l
l Unique System Dese.
THREE CHARGING PUMPS WITH A RATED FLOW OF 150 GPM AT 2500 PSIG EACH PROVIDE BORATED WATER FROM THE RWST THROUGH FCV-1CH 122 TO THE REACTOR COOLANT LOOPS. FT-1CH 122 SENSES CHARGING FLOW BETWEEN THE DISCHARGE OF PUMPS CH P-1A,B,C AND THE REGENERATIVE HEAT EXCHANGER.
OP MANUAL CHAPTER 7, RM-407 1 i
e I
BEAVER VALLEY POWER STATION ERDS DATA PolNT LIBRARY BV1 ERDS INPUT Date:
07/22/96 Reactor Unit:
SV1 Data Feeder:
IPC 1
NRC EROS Paraneter:
MN-FD FL-1A Point ID:
F0403A Pl.nt Spec Point Desc.
1 Generic /Cond Desc.:
STM GEN A MAIN FEEDWATER FLOW Analog / Digital:
A Engr Units / Dig States:
KLB/HR Engr Units Conversion:
N/A Minimum Instr Range:
0 Maximum Instr Range:
4612 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
S Number Of Sensors:
1 How Processed:
N/A Sensor Locations:
SEE UNIQUE SYSTEM DESCRIPTION FIELD Alarm / Trip Set Points:
HI ALM & 4400 KLB/HR/ LOW ALM a -2 KLB/HR NI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply Turn on Power Level:
N/A Instrument Failure Mode:
LOW Temperature Compensation For DP Transmitters:
N I
Level Reference Leg:
N/A Unique System Desc.
FT-1FW 476 PROVIDES MAIN FEED FLOW INDICATION AT THE MAIN CONTROL SOARD, A $1GNAL TO PNL-AMSAC AND SIGNALS TO THE SOLID STATE i
I PROTECTION SYSTEM (SSPS). TWO MAIN FEED PUMPS (1FW-P-1 A,B) RATED AT 15200 GPM AT 1900 TDH SUPPLY FEEDWATER TO THREE STEAM GENERATORS. FT-1FW 476 SENSES MAIN FEED FLOW TO SG A BETWEEN THE FIRST POINT FEED WATER HEATER AND FEED REGULATING VALVE
( F CV-F W4 78 ). OP MANUAL CHAPTER 24, RM 424 1 I
i
+
e I
1 BEAVER VALLEY POWER STATION ERDS DATA PO!NT LIBRARY I
BV1 ERDS INPUT Date:
07/22/96 Reactor Unit:
BV1 Data Feeder:
IPC NRC EROS Parameter:
EXTRA 6 Point ID:
F0404A Plant Spec Point Desc..
SG A UNCORR FW 2 FLOW Generic /Cond Desc..
STM GEN A MAIN FEEDWATER FLOW Analog /Digitat:
A Engr Units / Dig States:
KLB/HR Engr Units conversion:
N/A Minimum Instr Range:
0 Maximum Instr Range:
=612 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
S Number Of Sensors:
1 How Processed:
N/A Sensor Locations:
SEE UNIQUE SYSTEM DESCRIPfl0N FIELD Alarm / Trip Set Points:
41 ALM a 4400 KLB/HR/LO ALM & 2 KLB/HR NI Detector Power Supp!y Cut-nff Power Level:
N/A NI Detector Power Supply Turn on Power Level:
N/A Instrument Failure Mode:
LOW Temperature Compensation f or DP Te6nsmitters:
N Level Reference Leg:
N/A Unique System Dese, fi 1FW 477 F90vlDES MAIN FEED FLOW INDICATION AT THE MAIN CONTROL BOARD, A S10hAL TO PNL-AMSAC AND SIGNALS TO THE SOLID STATE j
FROTECTION SYSTEM (SSPS). TWO MAIN FEED PUMPS (1FW-P-1A,B) RATED AT l
15200 GPM AT 1900 TDH SUPPLY FEEDWATER TO THREE STEAM GENERATORS.
FT-1FW 477 SENSES MAIN FEED FLOW 10 SG 4 BETWEEN THE FIRST P0lNT FEED WATER HEAirR AND FEED REGULATING VALVE (FCV-FW478). OP MANUAL CMAPTER 24, RM 424-1 i
I l
i
e 4
e BE AVER VALLEY POWER STATION tRDS DATA POINT LIBRARY BV1 ERDS INPUT Date:
07/22/96 Reactor Unit BV1 Data Feeder:
MN-FD-FL 2B Point ID:
F0423A Plant Spec Poir.t Desc.?
SG B UNCORR FW 1 FLOW Generic /Cond Desc.
A Engr Units / Dig States:
KLB/NR Engr Units Conversion:
N/A Minimum Instr Range:
U Maximum Instr Range:
4612 l
Zero Point
Reference:
N/A Reference Point Notes:
N/A
)
PROC or SENS:
S l
Number Of Sensors:
1 How Processed:
N/A Sensor Locations:
SEE UNioVE SYSTEM DESCRIPfl0N FIELD Alarm / Trip Set Points:
HI (LM @ 4400 KLB/HR/LO ALM @ -2 KLB/HR N1 Detector Power Supply Cut-off Power Level:
N/A NI Detector Power Supply Turn-on Power Level:
N/A Instrument Failure Mode:
LOW Temperature Compensation For DP transmitters:
N Level Ref erence Leg:
N/A Unique System Desc.*
Ff 1Fw 486 PROVIDES MAIN FEED FLOW INDICATION AT THE MAIN CONTROL I
60ARD, A SIGNAL TO PNL-AMSAC AND SIGkALS TO THE SOLID STATE PROTECTION SYSTEM (SSPS). TWO MAIN FEED PUMPS (1FW-P-1 A,B) RATED AT 15200 GPM AT 1900 TDM SUPPLY FEEDWATER TO THREE STEAM GENERATORS.
FT-1Fw 486 SENSES MAIN FEED FLOW TO SG B BETWEEN THE FIRST P0lNT FEED WATER HEATER AND FEED REGULATING VALVE (FCV FW488). OP MANUAL CHAPTER 24, RM 424-1.
I l
t
e 4
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY BV1 ERDS INPUT Date:
07/22/96 Reactor Unit:
BV1 Data Feeder:
IPC i
NRC ERDS Parameter:
EXTRA 7 Point ID:
F0424A Plant Spec Point Desc.:
SG B UNCORR FW 2 FLOW Generic /Cond Desc.-
STM GEN B MAIN FEEDWATER FLOW Analog / Digital:
A Engr Units / Dig States:
KLB/HR i
i Engr Units Conversion:
N/A Minimum Instr Range:
0 Maximum Instr Range:
4612 Zero Point
Reference:
N/A I
l 1
Reference Point Notes:
N/A i
)
PROC or SENS:
5 Number of Sensors:
1 How Processed:
N/A Sensor Locations:
SEE UNIDUE SYSTEM DESCRIPTION FIELD Alarm / Trip Set Points:
Hi ALM @ 4400 KLB/NR/LO ALM @ -2 (LB/HR NI Detector Power Supply Cut-off Power Level:
N/A NI Detector Power Supply Turn-on Power Level:
N/A Instrument f ailure Mode:
LOW Tempera ure Compensation for DP Transmitters:
N Level Ref erence Leg:
N/A Unique System Desc.
F f w-1FW -87 FROVIDES MAIN FEED FLOW INDICAtl0N AT THE MAIN CONTROL SDARD, A SIGNAL TO PNL-AMSAC AND SfGNALS TO THE SOLID STATE
&ALTECTION SVSTEM (SSPS). TWO MAIN FEED PUPPS (1FW P-1A,B) RATED AT 15200 GPM AT 1900 TDH SUFPLY FEEDWATER TO THREE STEAM GENERATORS.
FT lFW-487 SENSES MAIN FEED FLOW TO SG B BETWEEN THE FIRST PO!NT FEED WATER MEATER AND FEED REGULAf!NG VALVE (FCV-FW888). JP MANUAL CHAPTER 24, RM 424 1 i
I l
1
o BEAVER VALLEY POWER STATION EkDS DATA PolNT LIBRARv BV1 ERDS INPui Date:
0//22/96 1
Reactor Unitt SV1 Data Feeder:
MN-FD-FL 3C Point ID:
F0443A Plant Spec Pcint Desc.
SG C UNCORR FW 1 FLOW Generic /Cond Desc.
STM GEN C MAIN FEEDWATER FLOW Analog / Digital:
A Engr Units / Dig States:
KLB/HR Engr Units conversion:
N/A Minimum Instr Range:
0 Maximum instr Range:
4612 Zero Point
Reference:
N/A Ref erence Point Notes:
N/A PROC or SENS:
S Number Of Sensors:
1 How Processed:
N/A Sensor Locations:
SEE UNIQUE SYSTEM DESCRIPTION FIELD Alarm /7 rip Set Points:
Hi ALM @ 4400 KLB/HR/LO ALM @ -2 KLB/HR NI Detector Power Supply Cut-off Power Lrset:
N/A NI Detector Power Supply Turn-on Power Level:
N/A Instrument Failure Mode:
LOW Temperature Compensation For DP Transmitters:
N Level Ref erence Leg:
N/A l
Unique System Desc.t st-1FW 496 PROVIDES MAIN FEED FLOW INDICATION AT THE MAIN CONTROL BOARD, A SIGNAL TO PNL-AMSAC AND SIGNALS TO THE SOLID STATE PROTECTION SYSTEM (SSPS). TWO MAIN FEED PUMPS (1FW P-1A,B) RATED AT 15200 GPM AT 1900 TDH SUPPLY FEEDWATER TO THREE STEAM GENERATORS.
l FT 1FW 496 SENSES MAIN FEED FLOW TO SG C BETWEEN THE FIRST PolNT FEED WATER HEATER AND FEED REGULATING VALVE (FCV FW498). OP MANUAL CHAPTER 24, RM 424-1 a
f
\\
6 s
l BEAVER VALLEf POWE3 STATION ERDS DATA PolNT LIBRARY BV1 ERDS INPUT f
Date:
07/22/96 Reactor Unit:
By1 Data Feeder:
EXTRA 8 l
Point ID:
F0444A Plant Spec Point Dese.:
SG C UNCORR FW 2 FLOW Generic /Cond Desc.*
STM GEN C MAIN FEEDWATER FLOW Analog / Digital:
A Engr Units / Dig States:
KLB/HR Engr Units Conversion:
N/A Minintsn Instr Range:
0 Maximum Instr Range:
4612 Zero point
Reference:
N/A Reference Point Notes:
N/A l
PROC or SENS:
1 Number of Sensors:
1 How Processed:
N/A Sensor Locations:
SEE UN10UE SYSTEM DESCRIPTION FIELD Alarm / Trip Set Points:
HI ALM @ 4400 KLB/HR/LO ALM @ -2 KLB/HR NI Detector Power Supply Cut-off Power Level:
N/A N1 Detector Power Supply Turn-on Power Level:
h/A Instrument Failure Mode:
LOW Temperature Compensation For DP Transmitters:
N tevel Reference Leg:
N/A i
Unique System Desc.
FT-1FW-497 PROVIDES MAIN FEED FLOW INDICATION AT THE MAIN CONTROL BOARD, A SIGNAL TO PNL-AMSAC AND S10NALS TO THE SOLID STATE PR0fECfl0N SYSTEM (SSPS). TWO MAIN FiED PUMPS (1FW-P 1A,B) RATED AT 15200 GPM AT 1900 TDH SUPPLY FEEDWATER TO THREE STEAM GENERATOR $.
I FT-1FW 477 SEN5ES MAIN FEED FLOW 10 SG C BETWEEN THE FIRST POINT TEED WAILR NEATER AND FEED 4EGULATING VALVE (FCV-FW498). OP MANUAL C* APTER 2, RM 424 1 l
T BE AVER VALLE Y POWED ST Af lON ERDS DAT A PolNt L IBR ARY l
Bv1 EROS input Date:
07/22/96 Reactor Unit:
BV1 l
Data Feeder:
IPC l
NRC ERDS Parameter:
AX-FD-FL-1A Point ID:
F0601A Plant Spec Point Desc.,
SG A AUX FEED FLOW Generic /Cond Desc.
STM GEN A AUX!LIARY FJ FLOW Analog / Digital:
A Engr Units / Dig States:
GPM Engr Units Conversion:
N/A Minimum Instr Range:
0 Maximum Instr Range:
400 Zero Point Ref erence:
N/A Reference Point Notes:
N/A PROC or SENS:
S Number Of Sensors:
1 How Processed:
N/A Sensor Locations:
SEE UNIQUE SYSTEM DESCRIPTION FIELD Alarm / Trip Set Points:
N/A NI Detector Power Supply Cut-of f Power Level:
N/A N! Detector Power Supply Turn-on Power Level:
NrA Instrument Failure Mode:
LOW Temperature Compensation for DP Transmitters:
N Level Reference Leg:
N/A Unique System Desc.'
AX FD FL FROVIDED BY l STEAM DRIVEN (700 GPM) PUMP (1FW P-2) AND 2 l
ELECTRIC DRIVEN (350 GPM) PUMPS (1FW-P-3A,B) TAKING SUCTION ON PRIM l
PL ANT DEMIN STORAGE T ANK OR RIVER WATER SYSTEM. AFW PUMP (1FW-P-4)
TAKES SUCTION FROM THE DEMIN WATER STORAGE TANKS (1WT-TK-11,26) AND j
PRovlDES 440 700 GPM FLOW 10 BRING PLANT TO COLD SHUTDOWN. 1FW P-4 eEQUlkE3 BECAUSE ThE IST 3 PUMPS DO NOT COMPLY WITH SEPARATION 860VIREMENTS OF 10CFR50 AFP. R.
FT-1FW 100A SENSES AX FD FL TO SG A BETWEEN AX FD FL THROTTLE VALVES AND SG A. AX FD HDR CONNECTS WlfH PAIN FD LINE DOWNSTRE AM OF tee MAIN FEEDWATER ISOL VALVES.
l
i 1
I u
BEAVE3 VALLEY POWE3 STATION ERDS DAlA POINT LibkARY BV1 ERDS INPUT Date:
07/22/96 Reactor Unit:
BV1 Data Feeder:
AX FD-FL 28 Point ID:
F0602A Plant Spec Point Desc.
SG B AUX FEED FLOW Generic /Cond Desc +
STM GEN B AUXILIARY FW FLOW Analog / Digital:
A Engr Units / Dig States:
GPM Engr Units conversion:
N/A Minimum Instr Range:
0 l
1 Maximum Instr Range:
400 2ero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
5 Number Of Sensors:
1 How Processed:
N/A Sensor Locations:
SEE UNIQUE SYSTEM DESCRIPil0N FIELD Alarm / Trip Set Points:
N/A j
N1 Detector Power Supply Cut-off Power Level:
N/A N1 Detector Power Supply Turn-on Power Level:
N/A Instrument Failure Mode:
LL.
Temperature Compensation For DP Transmitters:
N Level Ref erence Leg:
N/A Unique System Desc..
i I
Ax FD FL FROV!DED BV 1 STEAM DRIVEN (700 GPM) PUMP (1FW-P-2) AND 2 I
ELECTRIC DRIVEN (350 GPM) PUMPS (1FW P-3A,B) TAKING SUCTION ON PRIM PLANT DEMIN STORAGE TANK OR R!VER WATER SYSTEM. AFW PUMP (1FW-P-4)
TAKES CUCTION FRDM THE DEMIN WATER STORAGE TANKS (1WT-TK 11,26) AND PROVIDeS 440 700 GPM FLOW TO BWING PL ANT TO COLD SHUTDOWN. 1FW-P-4 REQUIRED BECAUSE THE IST 3 PUMPS DO NOT COMPLY WITH SEPARATION REQUIREMENTS OF 10CFR50 A'v.
R.
FT 1FW-1008 SENSES AX FD FL TO SG B BETWEEN AX FD FL THROTTLE VALVES AND SG B. AX FD HDR CONNECTS WITH MAIN FD LINE DOWNSTkFAm of t*E MAIN FEEDWATER ISOL. VALVES.
l l
1 BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY BV1 EROS INPUT Date:
07/22/06 Reactor Unit Ev1 l
Data Feeder:
AX FD FL-3C Point ID:
F0605A Plant Spec Point Desc.:
SG C Aux FEED FLOW Generic /Cond Desc.:
STM GEN C AuxlLIARY FW FLOW Analog / Digital:
A Engr Units / Dig States:
GPM Engr Unit. Conversion:
N/A Minimum Instr Range:
0 Maximum Instr Range:
400 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
5 Number Of Sensors:
How Processed:
N/A Sensor Locations:
SEE UN!QUE SYSTEM DESCRIPil0N FIELD Alarm / Trip Set Points:
N/A NI Detector Power Supply Cut-off Power Level:
N/A N! Detector Power Supply Turn on Power Level:
N/A Instrument Failure Mode:
low Temperature Compensation For DP f ransmitter s:
A Level Reference Leg:
N/A Unique Syst em Desc..
i Ax FD FL PROVIDED BY 1 STEAM DelVEN (700 GPM) PUP.P (1FW-P 2) AND 2 ELECTRit DRIVEN (350 GPM) PUMPS (1FW-P 3A,B) TAKING SUCTION ON PRIM PLANT DEMIN STORAGE TANK OR WivER WATER SYSTEM. AFW PUMP (1FW-P-4) l TAKES SUCTION FROM THE OEM!N WATER STORAGE TANKS (1WT TK 11,26) AND FROVICEs 440-700 GPM F LOW TO BRING FL ANT 10 COLD SHUTDOWN.1FW-P 4 REuu! RED 6EcAuSE THE 1st 3 PUMPS DC h0i COMPLY WITH SEPARATION wrQulkFMENTS
<>F 10CFR50 APF. R.
FT-1FW-100C SENSES AX FD FL TO SG M f w[ f 4 Ax ID FL THkoffLE VALVES AND SG C. Ax FD MDR CONNECTS
..th MA;N FD LINE DowhSTFEAM OF tee MAIN FEEDWATER ISOL. VALVES.
I i
I l
BEAVER VALLEY POWER STAil0N ERDS DATA PolNT LIBRARv BV1 ERDS INPUT l
l Date:
07/22/96 Reactor Unit:
Ev1 1
Data Feeder:
IPC i
i NRC ERDS Parameter:
HPSI FLOW 1 Point ID:
F5940A l
Plant Spec Point Desc.:
HHS1 TO HOT LEG NDR FLOW j
Generic /Cond Desc..
HlCH PRESS SAFETY INJECTION FLOW Analog / Digital:
A Engr units / Dig States:
bpm Engr Units conversion:
N/A Minimun Instr Range:
O Maximum Instr Range:
1000 Zero Point
Reference:
N/A l
l Ref erence Point Notes:
N/A PROC or SENS:
S Number Of Sensors:
1 How Processed:
N'A Sensor Locations:
SEE UNIQUE SYSTEM DESLRIPTION FIELD Alarm / Trip Set Points:
N/A NI Detector Power Supply Cut-off Power Level; N/A
)
N1 Detector Power Supply Turn on Power Level:
N/A Instrument Failure Modet LOW Temperature Compensation For DP Transmitters:
N i
Level Reference Leg:
N/A Unique System Desc.:
THis VALUE IS THE FLOW FRDM THE HIGM HEAD SAFETY INJECTION PUMPS INTO THE HOT AND COLD REACTOR C001. ANT LOOPS A,B, AND C. CH-P-1A,B,C l
PROVIDE A HHS! FLOW RATE OF 150 GPM AT 2500 PSIG. FT-1SI-940 SENSES l
FLOW AT THE DISCHARLE OF CH-P-1A,B, AND C PRIOR TO THE HEADER l
CONNECTION TO THE NOT AND COLD LEGS OF RE ACTOR COOLANT LOOPS A, B, AND C. OP MANUAL CHAPTER 11, RM-411 1, RM-407-1 I
l l
1
t
-o BEAVER VALLEY POWER STAfl0N ERDS DATA F01NT LIBRARY BV1 ERDS INPUT Date:
07/22/96 Reactor Unit:
BV1 Data Feeder:
aPSI Flow?
Point ID:
F5943A Plant Spec Point Desc.;
HHS! TO SIT FLOW Generic /Cond Dese.:
HIGH PRESS SAFETY INJECTION FLOW Analog / Digital:
A Engr Units / Dig States:
GPM Engr Units conversion:
N/A Minimum Instr Range:
Maximum Instr Range:
1000 2ero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
5 Number Of Sensors:
1 How Processed:
N/A Senso.' Locations:
SEE UNIQUE SYSTEM DESCRIPTION FIELD i
Alarm /frip Set Points:
N/A NI Detector Power Supply Cut-off Power Level:
N/A N1 Detector Power Supply Turn-on Power Level:
N/A Instrument Failure Mode:
Low Temperature Compensation f or DP Transmitters:
A i
Level Ref er ence Leg:
ufa Unique System Desc.:
THIS VALUE IS THE FLOW FROM THE HIGH WEAD SAFETY INJECTION PUMPS INTO THE BORON INJEC110N TANK *EADER. CH-P 1A,B,C PROVIDE A HMSI FLOW RATE OF 150 GPM AT 2500 PSIG, FT-151-943 SENSES FLOW FROM THE DISCHARGE OF CH-P-1A,B, AND C TO THE HIGH HEAD SAFETY INJECTION aEADER CONNECTION 10 f>E BORON INJECTION 1ANK. OP MANUAL CHAPTER 11, RM 411 1, &M-407 1
e BEAVER VALLEf power SIATION ERDS DATA P0fkT LIBRARY BV1 ERDS INPUT Date:
07/22/96 Reactor Unit:
BV1 Data Feeder:
LPSI-FLOW 1 Point ID:
F5945A Plant Spec Point Desc.*
91-P 14 DISCHARGE FLOW Generic /Cond Desc.-
LOW PRESS SAFETY INJECTION FLOW Analog / Digital:
A Engr Units / Dig States:
GPM Engr Units Conversion:
N/A Minimum Instr Range:
O Maximum instr Range:
4000 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
S Number Of Sensors:
1 How Processed:
N/A Sensor Locations:
SEE UNIQUE SYSTEM DESCRIPTION FIELD Alarm / Trip Set Points:
N/A NI Detector Power Supply Cut-off Power Level:
N/A NI Detector Power supply Turn on Power Level:
N/A Instrument Failure Mode:
Low Temperature Compensation For DP Transmitters:
N Level Reference Leg:
N/A Unique System Desc.
LOW ME AD SAFETY INJECfl0N PUMP SI P-1A TAKES A SUCTION ON THE BWST AND PROVIDES RATED FLOW OF 3000 GPM AT 111 PSIG TO THE REACTOR COOLANT LOOPS. FT-1SI 945 SENSES FLOW AT THE DISCHARGE OF THE LOW MEAD SAFETY INJECTION PUMP SI P-1A. -OP MANUAL CHAPTER 11, RM-407-1, RM-411 1 3
d d
BE AVER VALLE Y POWER ST ATION ERDS DATA POINI L IBR ARY BV1 EROS input Date:
07/22/96 Reactor Unit:
Bv1 Data feeder:
IPP o
NRC ERDS Parameter:
LPSI-FLOW 2 Point ID:
F5946A Plant Spec Point Desc..
St-P 1B DISCHARGE FLDW Generic /Cond Desc.:
LOW PRESS SAFETY INJECil0N FLOW Analog / Digital:
4 Engr Units / Dig States:
GPM Engr Units Conversion:
N/A Minimum Instr Range:
0 Maxinnai inst r Range:
0C Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
S Number Of S<"mors:
1 How Processed:
N/A Sensor Locations:
SEE UN!auE SYSTEM DESCRIPTION F ELD Alarm / Trip Set Points:
N/A NI Detector Power Supply Cut-of f Power tevet:
N/A NI Detector Fower Supply Turn-on Power Level:
N/A Instrument failure Mode:
LOW Temperature Compensation For DP Transmitters:
N Level Refere ne Leg:
N/A Unique System Desc.
LDW nEAD SAFEtV INJECTION PUMP SI-P-1B TAKES A SUCTION ON THE BWST AND PRov! DES RATED FLOW OF 3000 GPM AT 111 PSIG TO THE REACTOR CDOLANT LOOPS. FT-1S!*046 SENSES FLOW AT THE DISCHARGE OF THE LOW HEAD SAFETY INJECTION PUMP St P 18. OP MANUAL CHAPTER 11, RM-407-1, RM 411-1
e S
BEAVER VALLEY F0WER 31A;10h tROS cATA P0thi LIBRARY BV1 ERDS INPUT Date:
07/22/96 Reactor Unit:
BV1 Data Feeder:
SG LEVEL 1A Point 10:
LO403A Plant Spec Point Desc.
5G A WIDE RANGE LEVEL Generic /Cond Desc..
STEAM GEhERATOR A WATER LEVEL Analog / Digital:
A Engr Units / Dig States:
Engr Units conversion:
N/A Minimum Instr Range:
0 Maximum Instr Range:
100 Zero Point
Reference:
UTUBES Reference Point Notes:
SEE UNicuE SYSTEM DESCRIPTION FIELD PRDC or SENS:
S Number Of Sensors:
1 How Processed:
N/A Sensor Locations:
SEE UNIQUE SVGTEM DESCRIPTION FIELD Alarm / Trip Set Points:
HIGH ALM @ 70 %/LO ALM @ 43 i NI Detector Power Supply Cut-off Power Level:
N/A NI Detector Power Supply Turn-on Power Level:
N/A Instrument Failure Mode:
LOW Temperature Compensation f or DP Transmit ters:
N Level Reference Leg:
s/A unique System Dese. t LT 1FW-477 SENSES WIDE 8ANGE SG A LEVEL AND TRANSMITS A SIGNAL TO THE MAIN CONTROL f,OARD, THE EMERGENCY SHUTDOWN PANEL AND THE l
AUXilLARV FEED PUMP ROOM. (SEE ATTACKED % LEVEL VRS. CALLONS CURVE)
LT-1FW 477 SENSES WIDE RANGE LEVEL BETWIEN THE UPPER TAP AT 789'
'1" AND THE LOWER TAF AT 752' ON SG A. ZERO REF: TOP OF U TUBES ELEV 775'9", NORMAL WATER LEVEL IS AT ELEV 783'2".
REF: OP MAN.
CaAF.
4; ISO 6.2. 2743 l
t l
I
I BEAVER VALLEY POWER STAil0N EkDS DATA PolNT LlBRARY BV1 EPDS INPUT Date:
07/22/96 1
Reactor Unit:
SV1 Data Feeder:
SG LEVEL-28 Point ID:
LO423A Plant Spec Point Desc.
SG B W!DE RAhGE LEVEL Generic /Cond Desc..
STEAM GENERATOR B WATER LEVEL Analog / Digital:
A Engr Units / Dig States:
Engr Units Conversion:
h/A j
Minimum Instr Range:
0 Maximum Instr Range:
100 j
2ero Point
Reference:
UTUBES Reference Point Notes:
SEE UhluuE SYSTEM OESCRIPTION FIELD PROC or SENS:
S Number Of Sensors:
1 How Processed:
N/A Sensor Locations:
SEE UNIQUE SYSTEM DESCRIPT!DN FIELD l
j Alarm / Trip Set Points:
HIGN Atm & 70 x/LO ALM a 43 %
l NI Detector Power Supply Cut off Power Level:
N/A i
NI Detector Power Supply Turn-on power Levet:
N/A l
Inst runent failure Mode:
LOW Temperature Compensation for DP Transmitters:
N Level Reference Leg:
N/A Unique System Desc.
l LT 1Fw-487 SE45ES WIDE R ANGE SG B LEVEL AND TRANSMITS A $1GNAL TD
'-E MA l% CONT E Ds boAka, ThE EMERCENCY SHUTDOWN PANEL AND THE auxitlARV FEED eUMP kuoM. (LEE ATTACHED % LEVEL VRS. GALLONS CURVE). LT-1T c;87 SENSES WIDE RANGE LEVEL BETWEEN THE UPPER TAP AT 734' ild AND THE LDWER TAP AT 742' ON SG B. ZERO REF: TOP OF u-TUBES ELEV 775' 9a. NORMAL WATER LEVEL !$ AT ELEV 783' 2".
REF:
OP MAN. CHAP. 24-2744
I e
l i
i BEAVER kALLEY POWER STA110N ERDS DATA POINT LIBRARY BV1 ERDS INPUT Date:
07/22/06 Reacto" Unit Ev1 1
Data Feeder:
IPC t
NRC ERDS Parameter:
SG-LEVEL-3C Point ID:
LD443A Plant Spec Point Desc.4 SG C WIDE RANCE LEVEL Generic /Cond Desc.
- STEAM wENERATOR C hAlfR LEVEL Analog / Digital:
A Engr Units / Dig States:
Engr Units Conversion:
N/A l
Minintrn Instr Range:
0 Maximum Instr Range:
10v Zero Point
Reference:
UTUGES i
Reference Point Notes:
SEE UNIQUE SYSTEM DESCRIPTION f! ELD PROC or SENS:
S Number Of Sensors:
1 How Processed:
N/A Sensor Locations:
SEE UhluuE SYSTEM DESCR!PilON FIELD Alarm / Trip Set Points:
e!GM ALM @ 70 %/LO ALM @ 43 %
NI Detector Power Supply Cut-off Power tevet:
N/A l
l NI Detector Power Supply Turn-on Power Level:
N/A i
Instrument Failure Mode:
LOW Temperature Compensation For DP Transmitters:
N
[
Level Ref erence Leg:
N/A 1
1
(
Unique Systen Desc..
LT-1FW-497 SENSES WICE RANGE SG C LEVEL AND TRANSMITS A SIGNAL TO l
THE MAIN CONTROL BOAkD, THE EMERGENCY SHUTDOWN PANEL AND THE AUXILIARY FEED PUMP 830M. (SEE ATTACHED % LEVEL VRS. GALLONS LUE JE ). LT-1FW 497 SENSES WIDE RANCE LEVEL BETWEEN THE UPPER TAP AT 78%' 11" AND f*E LOWER T AP AT 742' ON SG C. ZERO REF: TOP 0F U Iv6ES ELEV 775' 9". NORMAL WATER LEVEL 15 AT ELEV 783' 2".
REF:
Ok MAN. CHAP. 24-27'5.
d e
l
f l
l BEAVER VALLEY power STATION ERDS DATA POINT tlBRARY l
BV1 ERDS INPUT 1
Date:
07/22/96 Reactor Unit:
BV1 l
Data Feeder:
CTMNT-SP-WR1 Point 10:
LO750A Plant Spec Point Desc..
RECIRC SUMP WTR LVL 1 Generic /Cond Dese.
CTMNT SUMP WIDE RANGE LEVEL Analog / Digital:
A Engr Units / Dig States:
IN Engr Unita Conversion:
N/A Minimum Instr Range:
e Maximum Instr Range:
70 Zero Point
Reference:
COMPLX Reference Point Notes:
SEE UNIQUE SYS1EM DESCklFTION TIELD PROC or SENS:
S Number of Sensors:
1 How Processed:
N/A Sensor Locations:
SEE UN!QUE SYSTEM DESCRIPTION FIELD Alarm / Trip Set Points:
HI ALM a 72 IN NI Detector Power Supply Cut-off Power Level:
N/A NI Detector Power Supply Turn on Power Levet:
N/A Instrument failure Mode:
LOW Temperature Compensation For * (ransmitters:
4 Level Ref erence Leg:
N/A Unique System Desc.,
LT-1RS 151A PROVIDES WIDE RANGE CONTAINMENT SUMP JNDICATION AT THE MAIN CONTROL BOARD. LT-1RS 151A SENSES NORTH $1DE CONTAINMENT SUMP LEVEL (INSIDE REClRCULATING SFRAY PUMP 1A SUMP). ZERO REF: 6" ABOVE SUMP BOTTDM. kEF: OP MAN. CHAP, 13 l
1 l
e BEAVER VALLEY POWER STAf!ON ERDS DATA POINT LIBRARY BV1 ERDS INPUT Date:
07/22/96 Reactor Unit:
set Data Feeder:
CTMNT SP.WR2 Point ID:
LO751A 4
Plant Spec Point Desc.*
REClkC SUMP WTR LVL 2 Generic /Cond Desc..
CTMNT SUMP WIDE RANCE LEVEL Analog / Digital:
A Engr Units / Dig States:
IN Engr Units conversion:
N/A Minimum instr Range:
0 Maximum Instr Range:
90 Zero Point
Reference:
COMPix Reference Point Notes:
SEE UNicuE SYSTEM DESCRIPTION FIELD PROC or SENS:
NJnber Of Sensors:
1 How Processed:
N/A Sensor Locations:
SEE UN!QUE SYSTEM DESCRIPTION FIELD Alarm / Trip Set Points:
N! ALM @ 72 IN NI Detector Power Supply Cut-off Power Level:
N/A NI Detector power Supply Turn on Power Level:
N/A Instrument Failure Mode:
low Temperature Compensation f or DP Transmitters:
N Level Reference Leg:
N/A Unique System Desc.
f 1RS-151B PROVIDES wlDE RANCE CONTAINMENT SUMP INDICAfl0N AT THE 6
MAIN CONTROL 60ARD. Li-1kS-151B SENSES NORTH SIDE CONTAINMENT SUMP LEkEL IINSIDE RECIRCU6ATING SPRAY PUMP iB SUMP). ZERO REF: 6" ABOVE suwe SOffDM. kEF: OP MAN, CHAP. 13 i
l
l 1
I l
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBR ARY 1
BV1 ERDS INPUT J
i Date:
07/22/96 l
Reactor Unit:
g/1 Data Feeder:
IPC 1
i I
NRC ERDS Parameter:
CNMNT-SP NR1 Point ID:
LO752A
)
l Plant Spec Point Desc.*
Generic /Cond Desc.-
CNMNT SUMP NARROW RANGE LEVEL l
Analog / Digital:
A I
> Engr Units / Dig States:
IN l
Engr Units conversion:
N/A l
Minimum Instr Range:
3 Maximum Instr Range:
15 Zero Point
Reference:
N/A l
Reference Point Notes:
N/A 1
PROC or SENS.
Number Of Sensors:
How Processed:
N/A l
l Sensor Locations:
SEE UN!GUE E? STEM DESCRIPil0N FIELD i
Alarm / Trip Set Points:
MI ALM @ 8.5 IN/LO ALM a 3.0 IN NI Detector Power Supply Cut off Power Level:
N/A N1 Detector Power Supply Turn-on Power Level:
N/A l
Instrument failure Mode:
law Temperatur e Compensat ion For DP Transmitters:
N Level Reference Leg:
N/A l
Unique System Desc.:
LT-IDA 100 PROVIDES NARROW RANGE CONTAINMENT SUMP INDICATION AT THE MAIN CONTROL BOARD AND FRCVIDES START /STOP SIGNALS TO THE CONTAINMENT SUMP PUMPS. LT-1DA 100 SENSES WATER LEVEL IN THE SOUTH SILE OF THE CONTAINMENT SUMP (720 GAL). OP HANUAL CHAPTER 9 l
l
=
l BEAVER VALLEY POWCR STATION ERDS DATA PolNT LIBRARY BV1 ERDS INPUT i
Date:
07/22/96 Reactor Unit:
DV1 Data Feeder:
REAC VES LV1 Point ID:
L3204A Plant spec Point Dese.:
RX VESSEL FULL RANGE LEVEL A
Generic /Cond Desc.?
REACTOR VESSEL WATER LEVEL Analog / Digital:
A Engr Units / Dig States:
Engr Units Conversion:
N/A Minimum Instr Range:
0 Maximum Instr Range:
120 Zero Point
Reference:
TAF Reference Point Notes:
T Af r728'8"(274" FROM BOT RX VESS)=62.5%
PROC or SENS:
S Number Of Sensors:
1 l
How Processed:
N/A Sensor Locations:
SEE UN!QUE SYSTEM DESCRIPTION FIELD Alarm / Trip Set Points:
N/A NI Detector Power Supply Cut-off Power Level:
N/A NI Det.ctor Power Supply Turn-on Power Level:
N/A Instrument Failure Mode:
LOW Temperature Compensation For DP Transmitters:
e Level Reference Leg:
WET Unique Syst em Desc..
CONNECTIONS TO THE RX VES HEAD AND INCORE INSTRUMENTATION TUBE #8 AT THE SEA TABLE ARE THE SENSING POINTS. REFERENCE LINE TUBING 5
RUNS FROM THESE POINTS TO HIGH VOLUME SENSORS WHICH ISOLATE THE RCS F D DM THE REMAINDER OF THE RvLis TUBING. CAPILLARY TUBING RUNS FROM INE HIGH VOLUME SENSORS THROUGH THE CNMNT WALL TO HYDRAULIC ISOLATORS. RTD'S ARE INSTALLED ON CAPILLIARY LINES FOR CNMNT TEMP.
COMPENSATION. ICCM RECEIVES TRANSMITTER OUTPUT. READING IS INVALID l
It RCP5 ARE RUNNING. LT-1RC-1311 SENSES RX VES LEY BETWEEN THE TOP OF THE Rx VES MEAD ELEV 745'10" TO THIMBLE GUIDE TUBE #8 ELEV.
I l
BEAVE0 VALLEY POWER STATION ERDS DATA POINT LIBc4Ry BV1 ERDS INPUT Date:
07/22/96 Reactor Unit:
BV1 Data Feeder:
REAC-VES LV3 Point ID:
L3206A Plant Spec Poit.t Desc..
Rx VESSEL DYNAMIC LEVEL
-A Generic /Cond Desc.
REACTOR VESSEL WATER LEVEL Analog / Digital:
A l
Engr Units / Dig States:
Engr Units Conversion:
N/A Minimum Instr Range:
0 Maximum Instr Range:
120 Zero Pcint
Reference:
N/A i
Ref erence Point Notes:
N/A PROC or SENS:
S Number of sensors:
1 How Processed:
N/A Sensor Locations:
SEE UNIQUE SYSTEM DESCRIP110N FIELD Alarm / Trip set Poir.ts:
N/A NI Detector Power Supply Cut-of f Power Level:
N/A NI Detector Power Supply Turn-on Power Level:
N/A Instrument Failure Mode:
LOW Temperature Compensation For DP Transmitters:
r Level Reference Leg:
WET Unique System Desc..
CONNECTIONS To THE h.
ESSEL AT THE INCORE INSTRUMENTATION TUBES SENSE Rx VESSEL CORE AND INTERNAL DP, REFERENCE LINE TUBING RUNS FROM THE INSTRUMENT TUBES TO HIGH VOLUME SENSORS WHICH ISOLATE THE RCS FROM THE REMAINDER OF THE RVLIS TUBING. CAPILLARY TUBING RUNS FROM TMF MIGH VOLUME SENSCRs THROUGH THE CNMNT WALL TO HYDRAULIC iSOLATC95. RTD'S ARE INSTALLED ON CAPlLLARY LINES FOR CNMNT TEMP.
COMPENSAfl0N. ICCM RECEIVES TRANSMITTER DUTPUT. THIS READING IS INVALID UNLESS THE RCPS ARE RUNNING. LT-1RC-1312 SENSES DP ACROSS Rx VESSEL AND INTERNALS WHEN ANY RCPS A9E RUNNING.
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY BV1 ERDS INPUT Date:
07/22/96 Reactor Units bv1 Data Feeder:
kEAC Vii LV2 Point ID:
L3210A Plant Spec Poir.t Desc.:
RX VESSEL FULL RANGE LEVEL
-B Generic /Cond Desc.:
REACTOR VESSEL WATER LEVEL Analog / Digital:
A Engr Units / Dig States:
L Engr Units Conversion:
N/A Minimum instr Range:
Maximum instr Range:
120 Zero Point Ref erence:
TAF Reference Point Notes:
T A F = 728'8a(274" FROM BOT RX VESS)=62.5%
PROC or SENS:
S Nunber Of Sensors:
1 How Processed:
N/A Sensor Locations:
- Et JNiuuE >YSTEM DESCRIPT!ON FIELD Alarm / Trip Set Points:
N/A N1 Detector Power Supply Cut-off Power Level:
N/A N1 Detector Power Supply Turn-on Power Level:
N/A Instrument Failure Mode:
LOW Temperature Compensation for DP Tron >mittern:
Level Ref erence Leg:
i/C i Uninue System Desc.
CONNECTIONS TO THE Rx VES HEAD AND INCORE INSTRUMENTATION TUBE #8 AT THE SEAL TABLE ARE THE SENSING POINTS. REFERENCE LINE TUBING kuNS FROM THESE POINTS TO HIGH VOLUME SENSORS WHICH ISOLATE THE RCS FROM THE REMAINDER OF THE RVLis TUBING. CAP!LLARY TUBING RUNS FROM THE HIGH VOLUME SENSORS THROUGH THE CNMNT WALL TO HYDRAULIC ISOLATORS. RfD'S ARE INSTALLED ON CAP!LLIARY LINES FOR CNMNT TEMP.
CDMPENSATION. ICCM kECE!VES TRANSMITTER DUTPUT. READING IS INVALID IF RCPS AGE RVNNING. LT-:RC 1321 SENSES RX VES LEV BETWEEN THE TDP of Tat xx NES -i AD LLEv 745'10" TO THIMBLE GUIDE TUBE #8 ELEV.
BEAVE3 VALLEY POWEQ STATION ERDS DATA POINT LIBRARY BV1 ERDS INPUT Date:
07/22/96 Reactor Unit:
SV1 Data Feeder:
REAC-VES LV4 Point ID:
L3212A Plant Spec Point Desc.
RX VESSEL DYNAMIC RANCE
-B Ceneric/Cond Desc.
REACTOR VESSEL WATER LEVEL Analog / Digital:
A Engr Units / Dig States:
t l
Engr Units Conversion:
ICCM RVLIS ALGUR]THM Minimun Instr Range:
0 Maximum Instr Range:
120 Zero Point
Reference:
N/A Ref erence Point Notes:
N/A I
PROC or SENS:
S Number Of Sensors:
1 How Processed:
N/A Sensor Locations:
SEE UNIQUE SYSTEM DESCRIPTION FIELD i
Alarm / Trip Set Points:
N/A N1 Detector Power Supply Cut-off Power Level:
N/A NI Detector Power Supply Turn-on Power Level:
N/A j
Instrument Failure Mode:
LOW Temperature Compensation For DP Transmitters:
Level Reference Leg:
WET Unique System Desc..
CONNECTIONS TO THE RX VESSEL AT THE INCORE INSTRUMENTATION TUBES SENSE RX VESSEL CORE AND INTERNAL DP REFERENCE LINE TUBING RUNS FRCN THE INSTRUMENT TUBES TO HIGH VOLUME SENSORS WHICH ISOLATE THE RCS FROM THE REMAINDER OF inE kVLis TUBING. CAPILLARY TUS]NG RUNS FROM TaE HIGH 's0LUME SENSORS T*kpuGH THE CNMNT WALL TO HYDRAULIC ISOLATOR $. RID'S ARE INSTALLED ON CAPILLARY LINES FOR CNMNT TEMP.
COMPENSATION. ICCM RECE]VES TRA'.sMITTER DUTPUT. THIS READING IS INVALID UNLESS THE RCPS ARE RUNNING. LT 1RC-1322 SENSES DP ACROSS ax VESSEL AND INTERNALS WHEN ANY RCPS ARE RUNNING.
BEAVER VALLE' POWEE STATION EDDS nata pois; tigeAa, BV1 EEDS INLU1 Date:
07/22/96 Reactor Unit:
Bv1 Data Feeder:
Ni SOURC-RNG Point 10:
N0031A Plant Spec Point Dese..
SOURCE RANGE DET 1 LOG FLUX Generic /Cond Desc..
NUCLEAR INSTRUMENTS SOURCE RANCE Analog / Digital:
A Engr Units / Dig States:
CPS Engr Units Conversion:
soU y = 6/5 0.0Lis) 1 Minimum Instr Range:
1 Maxintsn instr Range' N 'i Zero Point
Reference:
hiA Reference Point Notes:
N/A PROC or SENS:
S Number Of Sensors:
1 How Processed:
N/A Sensor Locations:
SEf UNiuuE SYSTfM DEsidlPflDN FIELD Alarm / Trip Set Points:
HIGN ALM @ 90,000 CPS / LOW ALM @ 0 CPS NI Detector Power Supply Cut-off Power Level:
1/21NTRNG>1E 10 NI Detector Power Supply Turn on Power Level:
2/2tNTENG<1E 10 Instrument Failure Mode:
LOW Temperature Compensation For DP Transmitters:
N Level Reference Leg:
N/A Unique System Desc.
- LE 8ANGE FkOVIDEs power LEVEL INDICATION FROM ABOUT 10E-10 % TO CE+4 A.
SOUdCE RANGE power LEVEL IS CALIBRATED FROM 1 TO 10E6 i
COUNTS PER SECONDS. N 31 (SEE ATTACHED NIS DETECTOR LOCATION DWG.)
OP MANUAL CHAPTER 2 l
l BEAVER VA6LEr POWER STArlCN ERDS DATA POlNT Ll6RARY BV1 ERDS INPUT l
Date:
07/22/96 Reactor Unit:
BV1 Data Feeder:
EX1RA$
Point 10:
N0032A Plant Spec Point Desc..
SOURCE RANGE DET 2 LOG Flux Generic /Cond Desc.:
NUCLEAR INSTRUMENTS SOURCE RANCE Analog / Digital:
A l
Engr Units / Dig States:
CPS Engr Units Conversion:
.uG V = 6/5 (v0LTS) -1 i
I
?
Minimum Instr Range:
1 i
Maximum Instr Range:
1ES
)
Zero Point Ref erence:
N/A l
Reference Point Notes:
h/A PROC or SENS:
S Number O' Sensors:
1 How Processed:
N/A Sensor Locations:
SEE UNtoUE SYSTEM DESCRIPTION FIELD Alarm / Trip Set Points:
w!GM ALARM @ 90,000 CPS N1 Detector Power Supply Cut-off Power Level:
1/2iNTRNG>1E-10 Ni Detector Power Supply Turn-on Power Level:
2/21NTRNG<1E 10 Ins t runent Failure Mode:
LCW Temperature Compensation For DP Transmitters:
A Level Ref erence Leg:
N/A Unique System Dese, l
500WCE RANGE FROVIDES POWER LEVEL INDICATION FROM ABOUT 10E-1D % To
- ?E.
SOURCE RANGE POWER LEVEL IS CAllBRATED FROM 1 TO 10E6 4
C3UNTS 6ER SECOND. N-32 (SEE AITACHED NIS DETECTOR LOCATION DWG.)
OP MANUAL CHAPTER 2 a
e e
BEAVER VALLEY POWER STATION ERDS DATA POINT LisRAay BV1 ERDS INPUT Date:
07/22/96 Reactor Unit:
B41 Data Feeder IPC NRC ERDS Parameter:
N1-INTER-RNG Point ID:
N0035A Plant Spec Point Desc.*
INTERMEDIATE RANGE DET 1 LOG Flux Generic /Cond Desc..
NUC INSTRUMENTS, INT kANGE Analog / Digital:
A Engr Units / Dig States:
AMP Engr Units conversion:
LOG V = 8/5 (VOLTS) -5 Minimum Instr Range:
10E 11 Maximum Instr Range:
10E-3 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
S Number Of Sensors:
1 1
How Processed:
N/A j
Sensor Locations:
SEE JN!auE SYSTEM DESCRIPTION FIELD Alarm / Trip Set Points:
HIGH ALM @ 7E-w AMP / LOW AtM @ 0 AMP N1 Detector Power Supply Cut of f Power Level:
2/4 FWA kNGelbe NI Detector Power Supply Turn on Power Level:
5/4 PWR RNGs104 Instrument Failure Mode:
LDW Temperature Compensat ion f or DP Transmitters:
N Level Ref erence Leg:
N/A Unique System Desc.*
INTERMEDIATE RANGE LEVEL INDICATION FROM 10E-11 TO 10E-3 AMPS i
l'E2 % FULL RATED POWER. POWER COEAESPONDS TO AbouT 10E t 10 J
kANGE LEVEL INDICATION WILL NOT COME ON SCALE UNTil THE REACTOR POWER LEVEL W:SES TO ABOUT 10E 5 AMPS INTERMEDIATE RANGE LEVEL.
("17, FULL POWER). N 35 (SEE ATTACHED NIS DETECTOR LOCATION DWG.)
OE MANUAL CHAPTER 2.
I 1
e 4
BEAVER VALLEY POWER STATION FWDS DATA PClhi LIBRARY BV1 EEDS INEU1 Date:
07/22/96 Reactor Unit:
BV1 Data Feeder:
(PC NRC ERDS Paraneter:
EXTRA 4 Point ID:
NUC36A Plant Spec Point Dese.:
INTERMEDIATE RANGE DET 2 LOG FLUX Generic /Cond Desc.?
NUC INSTRUMENTS, INT RANGE Analog / Digital:
A Engr Units / Dig States:
AMP Engr Units conversion:
LOG V = B/5 (VOLTS) -5 Minimum Instr Range:
ICE-11 Maximum Instr Range:
10E 3 Zero Point Ref erence:
N/A Reference Point Notes:
N/A PROC or SENS:
S Number Of Sensors:
1 How Processed:
N/A Sensor Locations:
SEE UNIQUE SYSTEM DESCRIPTION FIELD Alarm / Trip Set Points:
HIGH ALM @ 7E 4 AMP / TOW ALM & 0 AMP N1 Detector Power Supply Cut-off Power Level:
2/4 i'WR RNG=104 N1 Detector Power Supply Turn-on Power Level:
3/4 PWR RNG<10%
Instrument Failure Mode:
L DW Temperature Compensation For DP Transmitters:
N Level Reference Leg:
N/A Unique System Desc..
INTERMEDIATE RANGE LEVEL INDICAfl0N FROM 10E-11 TO 10E-3 AMPS C0dRESPONDS TO ABOUT 10E-6 % TO 10E2 % FULL RATED POWER. POWER RANGE LEVEL INDICATION WILL NOT COME ON SCALE UNTIL THE REACTOR
&OwEa LEVEL RISES 10 ABOUT 10E 5 AdPS INTERMEDI ATE RANGE LEVEL. (~
1 % F UL L POWE R ). W 36 (SEE ATTACHED NIS DETECTOR LOCATION DWG.) OP MANUAL CHAPTER ?
BEAVER VALLEY POWER STATION EROS DATA POINT LIBRARY BV1 ERDS INPUT Date:
07/22/96 l
Reactor Unit:
BV1 Data Feeder:
IPC NRC EROS Parameter:
NI-POWER-RNG Point ID:
N0049A J
Plant Spec Point Desc.*
PWR RNG CHANNEL 1 FLUX (QUAD 4)
Generic /Cond Desc.:
NUCLEAR INSTRUMENTS, POWER RANGE Analog / Digital:
A Engr Units / Dig States:
x Engr Units Conversion:
L!NEAR Minimum Instr Range:
0 Maximum Instr Range:
120 Zero Point
Reference:
N/A Ref erence Point Notes:
N/A PROC or SENS:
Number of Sensors:
1 How Processed:
N/A Sensor Locations:
SEE UNIQUE SYSTEM DESCRIPil0N FIELD Alarm / Trip Set Points:
LOW POWER & -3 %/H1 ALM & 105 %
NI Detector Power Supply Cut off Power Level:
N /A NI Detector Power Supply Turn on Power Level:
N/A instrument Failure Moce:
Low Temperature Compensation For DP Transmitters:
N Level Ref erence Leg:
N/A Unique System Desc.
power RANCE LEVEL IS CALIBRATED FROM A SECONDARY PLANT CALIMETRIC CALCULATION TO PROVIDE FULL RATED POWER LEVEL. POWEA RANCE LEVEL IS i
AN AVER AGE of TNE UPPER AND LOWER DETECTOR FLUX LEVELS. N 41A &
f N-418 (SEE Af f ACHED Nt t DETECf DR LOCATION DWG.) UP MANUAL CHAPTER 2 i
BEAVER VALLEY POWER STAfl0N ERDS DATA POINT LIBRARY BV1 ERDS INPUT Date:
07/22/96 Reactor Unit:
sa Data Feeder:
ipe NRC ERDS Parameter:
EXTRA 1 Point 10:
N0050A Plant Spec Point Desc.-
PWR RNG CHANNEL 2 FLUX (QUAD 2)
Generic /Cond Desc.:
NUCLEAR INSTRUMENTS, POWER RANGE Analog / Digital:
4 Engr Units / Dig States:
Engr Units Conversion:
LINEAR Minimum Instr Range:
0 Maxinun instr Range:
120 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
S Number Of Sensors:
1 How Processed:
N/A I
Sensor Locations:
SEE UNIQUE SYSTEM DESCRIPTION FIELD Alarm / Trip Set Points:
LOW POWER @ -3 %/Mt ALM a 105%
NI Detector Power Supply Cut-off Power Level:
N/A i
N1 Detector Power Supply Turn-on Power Level:
N/A Instrument Failure Mode:
LOW j
Temperature Compensation For DP Transmitters:
N 1
Level Reference Leg:
N/A Unique Syst em Dese.
- FOWER R ANGE LEVEL 15 Call 6R ATED FROM A SECONDARY CALIMETRIC CALCULATION TO PROVIDE FULL RATED POWER LEVEL. POWER RANCE LEVEL IS AN AVERAGE OF THE UPPER AND LOWER DETECTOR FLUX LEVELS. N-42A &
N-e2B (SEE ATTACHED NIS DETECTOR LOCAfl0N DWG.) OP MANUAL CHAPTER 2
l f
l BEAVER tEV POWER STATION ERDS DATA Fo!NT LIBRAny BV1 EWDS INPUT l
Date:
07/22/96 Reactor Unit:
411 l
Data feeder:
IPC l
NRC EROS Paraneter:
ExfRA2 Point ID:
N0051A l
l Plant Sper Point Desc.
PWR RNG CHANNEL 3 FLUX (QUAD 1) 1 Generic /Cond Desc.
NUCLEAR INSTRUMENTS, POWER RANGE j
Analog / Digital:
A i
Engr Units / Dig States:
Engr Units Conversion:
LINEAE Minimum Instr Range:
il Maximum Instr Range:
120 Zero Point Ref erence:
N/A Reference Point Notes:
N/A PROC or SENS:
S Number Of Sennor.s:
1 How Processed:
N/A j
l Sensor Locations:
SEE UNIQUE SYSTEM DESCRIPT!DN FIELD Alarm / Trip Set Points:
LOW POWER @ -3 %/H1 ALM @ 105%
NI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply Turn-on Power Level:
N/A Instrument Failure Mode:
LOW Temperature Compensation For DP Transmittet3:
N Level Reference Leg:
N/A Unique System Desc.*
POWER RANCE LEVEL IS CALIBRATED FROM A SECONDARY PLANT CALIMETRIC CALCULATION TO PROVIDE FULL RAfiD POWER LEVEL. POWER RANGE LEVEL IS AN AVERAGE OF THE UPPER AND LOWER DETECTOR FLUX LEVELS. N-43A &
N 43B (SEE ATTACHED Nis DETECTOR LOCATION DWG.) OP MANUAL CHAPTER
)
l 2.
l l
i 1
l BEAVER VALLEY POWER STAi!ON ERDS DATA POINT LIBRARY BV1 ERDS INPUT Date:
07/22/96 Reactor Unit:
BV1 Data Feeder:
LtikA3 Point !D:
N0052A Plant Spec Point Desc.*
PWR RNG CHANNEL 4 FLUX (DUAD 3)
Generic /Cond Desc.-
NUCLEAR INSTRUMENTS, POWER RANGE Analog / Digital:
A Engr Units / Dig States:
l Engr Units Conversion:
( isEAk Hinimum Instr Range:
0 Maximum Instr Range:
120 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
S Number Of Sensors:
How Processed:
N/A Sensor Locations:
SEE UNIQUE SYSTEM DESCRIPfl0N FIELD Alarm / Trip Set Points:
LOW POWER @ 3 X/H1 ALM a 105%
NI Detector Power Supply Cut-off Power Level:
h/A N1 Detector Power Supply Turn on Power Level:
N/A Instrument Fallure Mode:
LSW Temperature Compensation For DP Transmitters:
N Level Reference Leg:
4/A Unique System Desc.;
POWER R ANGE LEVEL 15 CALIBR ATED FROM A 3ECONDARY PLANT CALIMETRIC CALCULAfl0N TO FROVIDE FULL RATED POWER LEVEL. POWER RANGE LEVEL is AN AVERAGE OF inE UPPER A**D LOWER DETECTOR FLUX LEVELS. N 44A &
N 4;B (SEE AffACwED NIS LCTECTOR SOCATION DWG.) OP MANUAL CHAPTER 2.
6 BEAVER VALLEY POWER STATION ERDS DATA PO:NT L;ERAsv BV1 ERDS INPUT Date:
07/22/96 Reacter Unit:
Sv1 Data Feeder:
RC5 PkE35URE Point ID:
PO498A Plant Spec Point Desc.
RCS LOOP 2 WIDE RANGE PRESS Generic /Cond Desc..
REACTOR COOLANT SYSTEM PRESSURE Analog / Digital:
A Engr Units / Dig States:
PSIC Engr Units Conversion:
N/A Minimum Instr Range:
u Maximum Instr Range:
3000 Zero Point
Reference:
N/A Ref erence Point Notes:
N/A PROC gr SENS:
S Number Of Sensors:
How Processed:
N/A Sensor Locations:
SEE UNIQUE SYSTEM DESCRIPTION FIELD Alarm / Trip Set Points:
Ml ALM & 2275 PSIG/LC ALM e O PSIG N1 Detector Power Supply Cut-of f Power Level:
N/A NI Detector Power Supply Turn on Power Level:
N/A Instrument f ailure Mode:
LOW Temperature Compensation for DP Transmitters:
N Level Reference Leg:
N/A Unique System Dese..
Pf-1RL 403 PROVIDES WIDE RANGE PRESSURE INDICATION AT THE MAIN CONTROL BOARD, AND THE BACK-UP [NDICATING PANEL. PT+1RC 403 ALSO PROVIDES AN OPEN AND CLOSE SIGNAL TO PORV (PCV-1RC 455C).
l l
PT-1RC 403 IS LOCATED IN CONTAINMENT. PT 1RC-403 SENSES PRESSURE l
BETWEEN THE REACTOR VESSEL AND LOOP B HOT LEG ISOLATION VALVE I
w]V-1PC 592. OP MANUAL CHAPTER 6, RM 406-1 l
l
I BEAVER VALLEY POWER STAf!0N ERDS DATA P0lNT LIBRARY BV1 ERDS INPUT Date:
07/22/96 Reactor Unit:
het Data Feeder:
Ivt NRC ERDS Paraneter:
E41RA9 Point ID:
PO499A Plant Spec Point Desc..
RCS LOOP 3 WIDE RANGE PRESS Generic /Cond Desc.
REACTOR COOLANT SYSTEM PRESSURE Analog / Digital:
A Engr Units / Dig States:
PSIG Engr Units Conversion:
N/A Minimum inser Range:
Maxintmi inst r Range:
3dv0 Zero Point
Reference:
N/A Ref erence Point Notes:
N/A PROC or SENS:
S Number Of Sensors:
1 How Processed:
N/A Sensor Locations:
SEE UN100E SYSTEM DESCRIPil0N FIELD I
Alarm / Trip Set Points:
HI ALM @ 2275 PSIG/LO ALM @ 0 PSIG NI be:ector Power Supply Cut of f Power Level:
N/A NI Dete: tor Power Supply Turn on Power Level:
N/A I ns t runent Failure Mode:
tow Temperature Compensation For DP Transmitters:
A i
I Level Ref erence Leg.
Unique Syst em Desc.
FT IRC 402 IS RCS WIDE RANGE PRESSURE INDICATION AT ThE MAIN CONTROL BOARD, AND THE BACK UP f *:L i tn i :NG PANEL PT 1RC-402 ALSO PROVIDES AN OPEN AND CLOSE SfoNAL TO PORV :PVC 1RC-455D).
PT-1RC-402 15 LOCATED IN CoeTAINMENT. PT-1RC 402 SENSES PRESSURE 6ETWEEN THE REACTOR VESSEL AND LOOP C MOT LE, ISOLATION VALVE MOV-1RC 596 GP MANUAL CnAlTER 6, kM 406 1 I
i l
l
e s
BEAVER VALLEY POWER 51AllON ERDS DATA PolNT LIBRARY BV1 Ends INPUT Date:
07/22/96 Reactor Unit:
SV?
Data Feeder:
LiMNT-PRESS Point ID:
P'008A Plant Spec Point Des:
WIDE RANGE CNMT PRESS CN 1 Generic /Cond Desc.?
CONTAlNMENT PRESSURE Analog / Digital:
A Engr Units / Dig States:
PSIA l
I Engr Units Conversion:
h/A Minimum Instr Range:
O Maximum Inst r Range:
i ';4 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
S Number Of Sensors:
1 How F rocessed:
N/A Sensor Locations:
SEE UNIQUE SYSTEM DESCRIPTION FIELD Alarm / Trip Set Points:
N/A N1 Detector Power Supply Cut off Power Level:
N/A Al Detector Power Supply Turn-on Power Level:
N/A instrument Failure Mode:
LOW Temperature Compensation For DP Transmitters:
N Level Ref erence Leg:
N 'a Unique System Dese.
E t ILM-101 A Pku.!DE 5 WIDE RANGE CONT AINMENT PRESSURE INDICATION AT inf MAIN CONTROL BOARD PT-1LM-101A SENSES CONTA!NMENT PRESSURE AT A I'EESSURE T AP LOCATED BETWEEN TV-1LM 100A1 AND TV-1LM100A2 (CONTAINMENT ISOLATION VALVES) AND CONTAINMENT. OP MANUAL CHAPTER 12
BEAVER VALLEY POWEk LIAllLN (RDS DAIA PU!Ni LibhAki j
SV1 ERDs INPUT Date:
07/22/96 Reactor Unit:
SV1 Data Feeder:
IPC 1
NRC ERDS Parameter:
EXTRA 21 Point ID:
P100GA Plant Spec Point Desc.
WIDE kANUE CNMT PRESS CH 2 Generic /Cond Desc..
CONTA!NMENT PkESSURE Analog / Digital:
A Engr Units / Dig States:
PSIA i
Engr Units Conversion:
N/A Minimum instr Range:
0 Maximum Instr Range:
j Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
5 i
Number Of Sensors:
1 How Processed:
N/A i
Sensor Locations:
SEE UNICuE SrsiEM DESCRIPTION FIELD Alarm / Trip Set Points:
N/A j
i NI Detector Power Supply Cut-of f Power Level:
N/A N1 Detector Power Supply Turn-on Power Level:
N/A 1
l Instrument failure Mode:
LOW j
Temperature Compensation For DP Transmitters:
N Level Reference Leg:
N/A Unique System Desc.
r' ILM-1018 PROVIDES WICE RANCE CONTAINMENT PRESSURE INDICATION AT THE MAIN CONTROL BCARD. PT-1LM 101B SENSES CONTAINMENT PRESSURE AT A PRESSURE TAP LOCATED BETWEEN TV 1LM-100A1 AND TV-1LM 100A2 (CONTAINMENT ISOLATION VALVES) AND CONTAINMENT. OP MANUAL CHAPTER 12.
BEAVER VALLEY power STATION ERDS D AT A Polkt LIBRARY BV1 ERDS INPUT f
Date:
07/22/96 l
Reactor Unit:
BV1 Data Feeder:
IpC 1
i NRC ERDS Parameter:
COND AE-RAD 1 Point ID:
R0029A Plant Spec Point Desc.:
CONDENSER AIR EJECTO9 Generic /Cond Desc.
COND AIR EJECTOR RADIDACTIVITY Analog / Digital:
A Engr Units / Dig States:
CPM Engr Unit, Conversion:
N/A Minimum Instr Range:
Maximum Instr Range:
1E6 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
S Number Of Sensors:
1 How Processed:
N/A Sensor Locations:
SEE UNIQUE SYSTEM DESCRIPT!0N FIELD Alarm / Trip Set Points:
al ALM & 408 CF=/LO ALM @ -100 CPM NI Detector Power Supply Cut off Power Level:
N/A i
NI Detector Power Supply Turn-on Power Level:
N/A Instrument Failure Mode:
LOW Temperature Compensation For DP Transmitters:
N Level R*ference Leg:
N/A Unique System Desc.
aM 154-100 CONiihuoUStY MONITORS THE EFFLUENT FOR GASOUS ACTIVITY ll 131, xE-133, (E-80) FROM inE CONDENSER AIR EJECTOR VENT. AN ALARM INDICATES A PRIMARY 70 SECONDARf LEAK. A HIGH HIGH 4ADICACTIVITY ALARM DIVE #TS THE GASEQUS DISCHARGE TO THE CONTAINMENT BUILDING FOR SUBSEQUENT DISCHARGE THROUGH THE ELEVATED GFLEASE POINT. A BETA SClhT]LLATION DETECTOR CONTINUOLSLY MONITORS THE CONDENSER AIR EJECTOR VENT. OP MANUAL CHAPTER 43, RM-422-1 i
l
4 1
i e
BEAVER VALLEY POWER STATION :kDS DATA POINT LIBRARY Gv1 EADS INeuf Date:
D7/2?/06 Reactor Unit:
BV1 Data Feeder:
EFF Llo-RAD 1 Point ID:
R0030A r
Plant Spec Point Desc.
LIQUID UASTE EFFLUENT Generic /Cond Desc.
EADIGACTiVI?v LJ RELEASED.10UID Analog / Dig tal:
A Engr Units / Dig States:
CPM Engr Units Conversion:
N/A Minimum Instr Range:
10 Maximum Instr Range:
1E6 Zero Point
Reference:
N/A Ref erence Point Notes:
N/A PROC or SENS:
s Number Of Sensors:
1 How Processed:
N/A Sensor Locations:
SEE UN!QUE SYSTEM DESCRIPt!ON FIELD l
Alarm / Trip Set Points; wl ALM 9 3.44E5 CPM /LO ALM @ 1600 CPM NI Detector Power Supply Cut off Power Level:
N/A N1 Detector Power Supply Turn-on Power Levet:
N/A Instrument Failure Mode:
LOW Temperature Compensation For DP Transmitters:
N Level Reference Leg:
N/A Unique System Desc.:
84 ILw 104 MONf10RS THE ACTIVITY (CO 6D & CS-137) 0F ANY i
G AD10AC11bE L.uJID WA51E DISCHARGED FROM THE STATION. A HIGH-HIGH Artgy:vi At.' u;1;CALLv TERMINATES FLOW BY CLOSING THE DISCHARGE L :!.i ISJLATION VALVES. A GAMMA SCINTILLATION DETECTOR MONITORS THE ACTIVITY OF RADIDACTIVE L10VID WASTE DISCHARGED DOWNSTREAM OF THE LAST POINT OF RADICACTIVE EFFLUENT ADDITION TO THE DISCHARGE HEADER. OP MANUAL CMAPTER 43, RM 417-1
BEAVER VALLEY POWER STATION ERDS DATA POINT LlBRARY BV1 ERDS INPUT Date:
07/22/96 Reactor Unit:
SV)
Data Feeder:
IPC NRC EROS Parameter:
SG BD RAD-1A Point ID:
R0034A Plant Spec Point Desc.
SIEAM GENERATOR BLOWDOWN Generic /Cond Desc..
sTM GEN A/B/C BLOWDOWN RAD LEVEL Analog / Digital:
A Engr Units / Dig States:
CPM Engr Units Conversion:
N/A Minimum Instr Rang.
?9 Maximum Instr Range:
1E6 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
S Number Of Sensors:
1 How Processed:
N/A Sensor Locations:
SEE UN!auE SYSTEM DESC#1PTION FIELD Alarm / Trip Set Points:
ni ALM a 1230 CPM /LO ALM & 100 CPM NI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply Turn-on Power Level:
N/A Instrument f ailure Mode:
LOW Tenperature Compensation For DP Transmitters:
N Level Reference Leg:
N/A Unique System Desc. '
RM-1BD-100 MDNITORS THE BLOWDOWN DISCHARGED FROM THE BLOWDOWN HEAT EXCHANGER DISCHARGE LINE FOR CO-60 AND CS 137. A HIGH HIGH ALARM MAV !NDICATE A PRIMARY TO SECONDARY LEAK. A GAMMA SCINTILLATOR LfiECTS ACTIVITY FROM SAMPLES TAKEN AT THE DISCHARGE OF THE 6.CWDOWN CRAIN MEAT EACHANGER. OP MANUAL CHAPTER 43.
a i
i e
l BEAVER VALLEY POWER ST ATION EROS DATA POINT LIBRARY BV1 ERDS INPUT Date:
07/22/96 Reactor Unit:
671 l
Data feeder:
RCS-LTD-RAD 1 Point 10:
R0036A Plant Spec Point Desc.:
RX COOLANT LETDOWN H1 RANGE Generic /Cond Dese.
- RAD LEVEL OF RCS LETDOWN LINE Analog / Digital:
A Engr Units / Dig States:
)
Engr Units Conversion:
N/A Minimum Instr Range:
10 1
Maximum Instr Range:
1E6 1
Zero Point
Reference:
N/A Reference Point Notes:
N/A 1
PROC or SENS:
S i
Number Of Sensors:
1 How Processed:
N/A Sensor Locations:
SEE UNIQUE SYSTEM DESCRIPfloN FIELD Alarm / Trip Set Points:
N1 ALM @ 6.0E5 CPM /LO ALM @ -6.4E3 CPM NI Detector Power Supply Cut-of f Power Level:
N/A N! Detector Power Supply Turn-on Power Levet:
N/A Instrument failure Mode:
LC.
Temperature Compensation For DP Transmitters:
N Level Reference Leg:
N/A Unique Syst em Desc.
- RM-1CH 101A MONITORS THE GROS $ ACTIVITY OF THE REACTOR COOLANT (CD-60 & CS-137) BY DRAW! AG SAMPLES FROM THE REACTOR COOLANT LETDOWN LINE AND DELAvlNG THEM TO FERMIT SUFFICIENT DECAY OF THE N j
l
'n is0 TOPE 6EF0&E THEY FASS SV THE DETECTORS. THIS IS AN JalCAI!ON OF FISSION ra) DUCTS EkiSENT IN THE REACTOR COOLANT. THIS R Ai! AT ION MONITOR F RO/IDE S f eE LOW AND HIGH RANCE INDICATION. A LAMMA SC!NTILLAi!ON DETECTOR MONITORS THE GROSS ACTIVITY OF THE REACTOR CDOLANT BY DRAWING $AMPLES FROM THE REACTOR COOLANT LETDOWN LINE DOWNSTEAM OF THE NON REGENERATIVE HEAT EXCHANGER. OM 43.
l I
l
a PEAVER VALLEY POWER STATION ERDS DA?A PolNT LIBRARY BV1 ERDS INPUT Date:
07/22/96 Reactor Unit:
Data feeder:
RCS LTD RAD 2 Point ID:
R0037A Plant Spec Point Desc.
RX COOLANT LETDOWN LO RANGE Ceneric/Cond Desc..
RAL LEVEL OF RCS LETDOWN LINE Analog / Digital:
A Enge Units / Dig States:
CPM Engr Units Conversion:
N/A Minimum Instr Range:
10 Maximum Instr Range:
IE6 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
L Number Of Sensors:
1
)
How Processed:
N/A Sensor Locations:
SEE UNIQUE SYSTEM DESCRIPTION FIELD Alarm / Trip Set Points:
nl ALM a 4.2E4 CPM /LO ALM @ -6.4E3 CPM NI Detector Power Supply Cut off Power Level:
N/A N1 Detector Power Supply Turn-on Power Level:
N/A Instrument Failure Mode:
.0W Temperature Compensation For DP Transmitters:
N Level Reference Leg:
N/A Unique System Desc.
EM Ita 101B MvNITORS INE GROSS ACTIVITY OF THE REACTOR COOLANT (CU 60 m CS 137) BY DkAWlNG SAMPLES FROM THE REACTOR COOLANT LFID0wN LINE AND DELAYING THEM TO PERMIT SUFFICIENT DECAY OF THE N 16 ISOTOPE BEFORE THEY PASS BY THE DETECTORS. THIS IS AN INDICATION OF FISSION PRODUCTS FRESENT IN THE REACIOR COOLANT. THIS RADIATION MUNITOR PROVICES THE LOW AND HIGH RANGE INDICATION A GAMMA 5CINTILLAfl0N DETECTOR MONITORS THE GROSS ACTIVITY OF THE REACTOR COOL ANT Bf OR AWING SAMPLE S FROM THE RE ACTOR COOLANT LETDOWN LINE DnWN5 TEAM Of T*E NON-atGENERATitE NEAT EXCHANGER. OM 43.
a
e 0
BE AVER VALLE f POWER ST A TICN ERDS DAT A POINT LIBRARY i
BV1 EEDS INPUT Date:
07/22/96 1
l Reactor Unit:
Bv1 Data Feeder:
CTMN1-RAD 1 Point 10:
R007DA Plant Spec Point Desc.
CNMT HIGH RANGE RAD CH 1 Generic /Cond Desc.-
RADIATION LEVEL IN CONTAINMENT Analog / Digital:
A Engr Units / Dig States:
E /Hk Enge Units Conversion:
N/A Minimun InAtr Range:
Maximum instr Range:
1E7 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
S Number Of Sensors:
1 How Processed:
N/A Sensor Locations:
SEE UNIQUE SYSTEM DESCRIPTION FIELD Alarm / Trip Set Points:
Hi ALM @ 3 R/NR NI Detector Power Supply Cut-off Power Level:
N/A N1 Detector Power Supply Turn-on Power Level:
N/A Instrument Failure Mode:
LOW Temperature Compensation For DP Transmit ters:
N Level Reference Leg:
N/A 1
Unique System Desc.*
RM-1RM-219A FUNCTIONS AS AN ACCIDENT DETECTOR MEASURING RADIATION l
LEbELS INSIDE CONTAlkMENT. AN 10N CHAMBER DETECTOR MONITORS ACCIDENT RADIATION LEVELS INSIDE CONTAINMENT ON THE CRANE WALL ABOVE T E OPER ATING FLOOR. OP MANUAL CHAPTER 43
e BEAVER VAttEY POWER STATION ERDS DATA POINT LIBRARY BV1 EkDS IN4UT Date:
07/22/96 Reactor Unit:
sv1 Data Feeder:
1pc NRC ERDS Parameter:
CTMNT RAD 2 Point ID:
R0071A Plant Spec Point Desc..
CNMT HIGH RANGE RAD CH 2 Generic /Cond Desc.
- RADIATION LEVEL IN CONTAINMENT Analog / Digital:
A Engr units / Dig States:
R/MR Engr Units Conversion:
N/A Minimum Insor Range:
1 Maximum Instr Range:
1E7 i
Zero S c
Reference:
N/A 9eference Point Notes:
N/A l
PROC or SENS:
S Number Of Sensors:
1 How Processed:
N/A Sensor Locations:
SEE UN!auE SYSTEM DESCRIPTION FIELD Alarm / Trip Set Points:
H1 ALM @ 3 RfMR N1 Detector Power Supply Cut-off Power Level:
N/A i
NI Detector Power Supply Turn on Power Levet:
N/A Ins t runent Falture Mode:
LOW Temperature Cowpensation For DP Transmitters:
N Level Ref erence Leg:
N/A Unique System Dese.:
RM-1RM-219B FUNCTIONS AS AN ACCIDENT DETECTOR MEASURING RADIATION LEVELS INSIDE CONTAINMENT, AN 10N CHAM 6ER DETECTOR MONITORS ACCIDENT RADI ATION LEVELS INSIDE CONT AINMENT DN THE CR ANE WALL 4
AB0VE THE OPERATING FLDOR. OF MANut: CHAPTER 43 s
4 i
a
i BEAVER VALLEY POWER STATION ERDS DATA POINT LISRARY BV1 ERD 5 IN UT Date:
07/22/96 Reactor Unit:
3V) i Data Feeder:
IPC NRC En.4 Parameter:
RwST LEVEL 1 Point 10:
RW5TLEY Plant Spec Point Dese.*
kWS1 AVERAGE LEVEL 1/2/3 Generic /Cond Desc..
80 RATED WATER STORAGE TANK LEVEL Analog / Digital:
A Engr Units / Dig States:
FEET Engr Units Conversion:
N/A Minimum Instr Range:
0 Manimum Instr Range:
c5 Zero Point
Reference:
COMPL)
Ref erence Point Notes:
SEE UNIQUE SYSTEM DESCRIPi!ON FIELD PROC or SENS:
P Number of Sensors:
3 How Processed:
StLIEVED VALUE PolNT Sensor Locations:
dEE UN!QUE SYSTEM DESCWIP110N FIELD Alarm / Trip Set Points:
N/A NI Detector Power Supply Cut-of f Power Level:
N/A NI Detector Power Supply Turn-on Power Level:
N/A Instrument Failure Mode:
LOW Temperature Compensation for DP Transmitters:
N Leve! Ref erence.,:
N/A Unique System Desc.
idE bec' mi Bel 15 kE FERPED TO AS REFUELING WATER STORACE TANK" (aW51). ThERE ;S ONE RWST AT BV1 WITH A CAPACITV 0F 446,035 GALLONS. THERE IS ABOUT 6,000 UNUSABLE GALLONS BELOW THE QUENCH SPPAf PUMP SUCTION, THERE ARE APPR0xlMATELY B483 GALLONS /FT. IN THE RWS1, (SEE ATTACHED ANr CURVE). RWST LEV SIGNAL 15 THE AVERAGE OF j
3, 2 GR A S!hCLE V
,E DEFF= LING om THE DEvlAil0N BETWEEN VALUES.
j LT-105-130A,0,C SENSE LEVE6 i THE BWST AT THE T36' 6" ELEVAfl0N.
2 FRO Ff. REf: 1*E BottDM CF hsST 15 AT 735' 6" ELEVATION AND THE SutfinN.!NE f(* OufNCe EkA' Powr5 !$ At 736' 3" ELEVA110N.
BEAVER VALLEY POWER STATION ERDS DATA PolNT LIBRARY BV1 ERDS INPUT Date:
07/22/96 Reactor Unit:
BV1 Data Feeder:
CL TEMP-1A Point ID:
rie9nA Plant Spec Point Desc.:
RCLA WR TCOLD Generir,Cond Desc.:
STM GEN A OUTLET TEMPERATURE Analog / Digital:
A Engr Units / Dig States:
DEGF Engr Units Conversion:
N/A Mininnn instr Range:
Maximum Instr Range:
70u Zero Point Ref erence:
N/A Reference Point Notes:
N/A PROC or SENS:
S l
l Number Of Sensors:
1 How Processed:
N/A l
Sensor Locations:
SEE UNIQUE SisTEM DESCRIPTION FIELD t
l Alarm / Trip Set Points:
Hi ALM D 650 DECF/LO ALM D 32 DEGF l
I N1 Detector Power Supply Cut-off Power Level:
N/A NI Detector Power Supply Turn-on Power Levet:
N/A Instrument Failure Mode:
L A' temperature Compensation For OP Transmitters:
N l
Level Reference Leg N/A 1
Unique Syst em Desc..
in. COOL ANT LOOP A COLD iEG TEMPERATURE SIGNAL IS SENT TO THE MA!N CONTPOL BOARD, PEMOTE SHUTDOWN PANEL, AND THE PLANT AND PSMS C3MPU 2kS. TE B 6 C 410 IS LOCATED BETWEEN RC P-1A DISCHARGE AND THE j
A LOOP STOP VALVE. OP MANUAL CHAPTER 6, RM-406-1 e
i a
I i
a
?
e BEAVER VALLEY POWER STAft0N ERDS DATA Polhi LIBRARY BV1 FRDS thPUT Date:
07/22/96 Reactor Unit:
BV1 i
Data feeder:
HL TEMP-1A
(
Point !D:
TU419A Plant Spec Point Desc.*
RCLA WR THOT Generic /Cond Desc.
STM GEN A INLET TEMPERATURE 1
Analog / Digital:
A Engr units / Dig States:
DEGF Engr Units Conversion:
N/A i
Minimun Instr Range:
0 Maximum Instr Range:
730 Zero Point Ref erence:
N/A Reference Point Notes; h/A FROC or SENS:
S 1
Number Of Sensors:
1 How Processed:
N/A Sensor Locations:
SEE UN!OUE SYSTEM DESCRIPTION FIELD I
(
Alarm / Trip Set Points:
HI alm @ 650 CECF/LC ALM & 32 CEGF t
l NI Detector Power Supply Cut-of + -
'.evel:
N/A
)
NI Detector Power Supply Turn on Power Level:
N/A Instrunent Failure Mode LOW Temperature Cnmpensation For DP Transmitters:
h l.
Level Ref erence Leg:
N/A Unique System Desc.
k4 COOi. ANT LOOP A MOf LEG TEMPER ATURE S!GNAL iS SENT TO THE MAIN CONTROL BOARC, aEMOTE SaufDDwN FANEL, AND THE PLANT AND PSMS COMPUTERS. TRS PC 413 IS LOCATED BETWEE'd A LOOP STOP VALVE AND coolant lhi 10 SG A. 00 MANUAL CHAPTER 6, RM 406 1 4
7
e BEAVEk VA. LEY r'Uwlk 51#'lON tRD; it!A POlki LISWARY BV1 EW9" iNau' Date:
07/22/96 Reactor Unit:
BV1 Data Feeder:
CL-fEMP-26 Point ID:
T0426A Plant Spec Point Desc..
eCLB WR TC0t0 Generic /Cond Dese.
STM GEN B QUTLET TEMPERATURE Analog / Digital:
A Engr Units / Dig States:
DEGF Engr Unit
- Conversion:
N/A Minimum Instr Range:
r, 4
Manin(sn instr Range:
76 J
Zero Point
Reference:
et -
Reference Point Notes:
N/A i
l PROC or SENS:
5 l
Number Of Sensors:
1 How Proc;_ -d:
h/A Sensor Locations:
SEE UNicuE SYSTEM DESCRIPT'ON FIELD Alarm / Trip Set Points:
el ALM 9 65G OEGF/LO ALM & 32 DEGF NI Detector Power Supply Cut-off Power Level:
N/A WI Detector Power Supply Turn-on Power Level:
N/A Instrument Failure Mode:
Law Tempe,ature Compensation For DP transmitters:
N j
Level Reference Leg:
f4 / A Unique System Desc.
u AAN1 eJOF B Lott LEG TEMFEkATURE SIGNAL IS SENT TO THE MAIN
=*
CONF 90L BOARD. EEMOTE SHUTDOWN PANEL, AND THE PLANT AND PSMS L3MPUTERS. TRB RC 42015 LOCATED BETWEEN RC-P 1B DibCHARGE AND THE B LOOP STOP VALVE. OF MANUAL CHAPTER 6, RM 406-1
BEAVER VALLEY power STATION ERDS DATA FOIN? LIEWARY BV1 ER?.S INPUT Date:
07/22/96 Reactor Unit:
BV1 Data Feeder:
IPC NRC ENDS Parameter; HL-TEMP 26 Point 10:
70439A Plant Spec Point Desc.'
RCLB WR THOT Generic /Cond Desc.:
STM GEN B INLET TEMPERATURE Analog / Digital:
A Engr Units / Dig States:
DEGF Engr Unitz Conversion:
N/A Minimum Inst.' Range:
O Maximum Instr Range:
700 Zero Point
Reference:
N,a Reference Point Notes:
N/A PROC cr SENS:
S Number Of Sensors:
1 l
How Processed:
N/A Sensor Locations:
SEE UNIQUE SYSTEM DESCRIPTION FIELD i
Alarm / Trip Set Points:
H! ALM @ 650 DE09/LO ALM 2 32 DEGF NI Detector Power Supply Cut-off Power Level:
N/A NI Detector Power Supply Turn on Power Level:
N/A l
Instrument Failure Mode:
LOL Temperature Compensation For DP Transmitters:
N Level Ref erence Leg:
N/A Unique System Desc.*
JOU; ANT [000 B MCT LEG TEMPERATURE SICNAL IS SENT TO THE MAIN
- JN !k ;.. BOAR EEMOTE SHuf.".OWN DANEL. #ND THE PLANT AND PSMS COMPU1EkS. Tub =C 423 l5 LOCATED SETWEEN B LDCP STDP VALVE AND C90LANT lNT 77 ' i, 5,
A> MANUAL CMA0TER 6, RM 406-1 J
I a
e BEAVER VALLEY POWER STATICA ERDS DATA PolNT ibRARY j
BV1 E4;S input l
1 Date:
07/22/96 Reactor Unit:
BV1 Data feeder:
IPC i
NRC ERDS Parameter:
CL-TEMP-3C Point ID:
f0446A Plant Spec Point Desc..
RCLC WR ICOLD Generic /Cond Desc.
STM CEN C auf! E i :FMcEnATURE Analog / Digital:
A Engr Units / Dig States:
DEGF Engr Units Conversion:
N/A Minimum Instr Range:
O Maximum Instr Range:
/00 Zero Point
Reference:
N/A Reference Point Notes:
NrA PRDC or SENS:
S Number Of Sensors:
1 How Processed:
N/A Sensor Locati9ns:
SEE UNicu6 SYSTEM DEscalPTION FIELD 1
Alarm / Trip Set P1ints:
91 ALM @ 650 t'EGF/LO ALM @ 32 DECT l
NI Detector Power Supply Cut off Power Levet:
N/A N1 Detector Power Supply T grn-on Fower Level:
N/A Instrument Failure Mode:
L OW Temperature Compensation For DP Transmitters:
N Level Ref erence Leg:
N/A Unique System Desc.
kn. COOLANI LOOP C COLD LEO TEMPERATURE S!CNAL l$ SENT TO THE MAIN
- 0%IROL BOARD, REMOTE SduTDOWN FANEL, AND THE PLANT AND PSMS
'rPUTEE S. TRT.+C 433 15 LOCATED GETWEEN RC-P 1C DISCHARGE AND THE LOOP STOP wALVE. LP MANUAL CPAPTER 6, RM 406-1
i s
BE AVER v ALLi v POWER ST AT !ON EkDS JATA POINT LIBRARY BV1 F#'S INPuf Lite:
07/22/96 l
Reactor Unit:
BV1 Data Feeder:
HL-TEMP-3C 1
Point ID-,
10459A Plant Spec Point Desc.
RCLC WR TWOT Generic /Cond Dese.
STM CEN C INLET TEMPERA *URE Analog /Digitat:
A Engr Units / Dig States:
DEGF 1
Engr Units Conversion:
N/A Minimum Instr Range:
U Maximum Instr Range:
71 2ero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
S i
Number Of Sensors:
1 How Processed:
N/A Sensor Locations:
SEE UNIQUE SYSTEM DESCRIPfloh FIELD l
Alarm / Trip set Points:
H: ALM @ 650 DEGF/LO ALM @ 32 DEGF N1 Detector Power Supply Cut-of f Power tevet :
S/A
\\
i NI Detector Power Supply Turn on Power Level:
k/L Instrument Failure Mode:
low Temperature Compensation For DP Transmitters:
N f
Level Ref erence Leg:
N/A j
4 Unique Sydtem Desc.
RR. COOLANI LOOP C HOT LEG TEMPERATURE SIGNAL IS SENT TO TNT. MAIN CONTROL BOAPD, EEMOTE SMUTDOWN FANEL, AND THE PLANT AND PSMS COMPUTE #S. TRB RC 433 IS LotATED SETWEEN C LOOP STOP VALVE AND CCW2L ANT INT f u (G C, 'sk MANUAL CMAPTER 6, RM-4D6 1 i
4
BEAVER VALLEV PCWER STATION EPOS DATA POINT LIBRARY SV1 ERDS INPUT Date:
07/22/96 Reactor Unit:
Bs Data feeder:
!MF CDut-Ex1 Point ID:
U0093 Plant Spec Point Desc..
IN CORE T/C 5 MOTTEST AVG l
Generic /Cond Desc.?
HIGHEST TEMPERATURE AT CORE Exti Analog / Digital:
A Engr Units / Dig States:
DEGF Engr Units Conversion:
N/A Minimum Instr Range:
32 Maximum Instr Range:
23n0 Zero Point Ref erence:
N/A Reference Point Noter-:
N/A PROC or SENS:
Number Of Sensors:
51 How Processed:
MARSAT Sensor Locations:
SEE UN!QUE SISTEM DESCRIPTION FIELD Alarm / Trip Set Points:
ni ALM @ 700 DEGF NI Detector Power Supply Cut-off Power Level:
N/A NI Detector e' mer Supply Turn-on Power Level:
N/A Instrument Failure Mode:
o JW Temperature Compensation For DP Transmitters:
N Level Reference Leg:
NrA 41nique System Desc. ;
U1003 15 CALCULATED BY "MARSAf" (MARGIN TO-SATURATION CALCULATION PROGRAM) WHIC* 15 EMECUTED EVERY $ SECONDS. MARSAT WILL READ ALL i k' ORE T /C$, dVJ RCS WibE R ANGE FRE55URE CURRENT VALUES. MARSAT
.ist T4h CAL,. ATE Tai AdEAGE Cf inE 5 HIGHEST GOOD VALUES (CETC t GwE (*
Avi 4.t) it, F L it 9 F k ap ALL thCORE T/CS.
l l
l l
BEAVER VALLEY POWER STAi!ON ERDS DATA FOINT LIBRARY l
BVI ERDS INPUT Date:
07/22/96 i
l Reactor Unit:
sv1 i
Data Feeder:
IPC l
l NRC EROS Parameter:
SUS-MARGIN 1 Point ID:
UOO94 l
Plant Spec Point Dese.'
SUSCOOL (AVG 5 Hi T/C)
Generic /Cond Desc.
SATURATloh IEMP - HIGHEST CET Analog / Digital:
e i
Engr Units / big States:
DEGF Engr Units Conversion:
N/A Minimum instr Range:
-35 Maximum Instr Range:
200 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
P I
Number of Sensors:
53 How Processed:
MARSAT Sensor Locations.:
SEE UN!QUE SYSTEM DESCRIPTION FIELD Alart / Trip Set Points:
N/A i
N1 Detector Power Supply Cut-of f Power Level:
N/A NI Detector Power Supply Turn-on Power Level:
N/A 1
t Instrument Failure Mode:
LOL i
Temperature Compensation For DP Transmitters:
A Level Reference Leg:
%/A Unique System Desc..
01002 15 CALCULATED EV "MARSAT" WHICH IS EXECUTED EVERY 5 SEC.
MARSAT WILL READ INCORE T/CS (CETCS) AND RCS WIDE RNG. PRESS, (P)
CusRENT VALUES. MARSAT WILL THEN EVAL. THE AVG. OF THE 5 HIGHEST GOOD VALUES SELECTED FROM ALL CETCS.
MARSA.' WILL ALSO SELECT THE LOWEST LOOD VALUE OF THE 2 RCS WIDE PNG. PS. THIS LOWEST GOOD RCS sU,E RN;. P w!LL TeEh SE CONVERTED (VIA STEAM TABLE ROUTINE
) Tr; #CS i-SAT MINIMJW.
MAkSAI WILL Fili 4LLY TAKE INE DIfF.
M:LEEN *C5 T-$AT 4
SEAVER VALLEY POWER ST Afloh ERDS DATA POINT LIBRARY BV1 ERDS INPUT Date:
07/22/96 Reactor Unit:
Sv1 Data Feeder:
CDkE-FLOW 1 Point ID:
UO400 e
Plant Spet Point Desc. '
RCLA UNCDkRECTED FLOW 1/2/3 AVG Ceneric/Cond Desc.
TOTAL REACTOR COOLANT FLOW 4
Analog / Digital:
A Engr Units / Dig States:
2 Engr Units conversion:
N i t.
Minimum Instr Range:
0 Maximum Instr Range:
120 Zero Point Ref erence:
N/A Reference Point Notes:
N/A PROC or SENS:
P Number Of Sensors:
How Processed:
BEllEVED VALUE ALGORITHM Sensor Locations:
SEE UNiouE SYSTEM DESCRIPTION FIELD Alarm / Trip Set Points:
M1 ALM @ 120 %/LO ALM @ 92 %
NI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply Turn on Power Level:
N/A Instrument Failui e Mode:
.Jw Temperature tempensation For DP fransmitters; N
Level Reference Leg:
- r. / 4 Unique Syst em Desc.
- A9CSFLOW IS THE AVERAGE OF THREE, TWO OR A SINGLE FLOW VALUE DEPENDING ON 1eE DEvlAT:0N SETWEEN FLOW SIGNALS. RC-P 1A,B,C EACH i
MAVE A DESIGN FLOW RATE GF 'S,500 GFM AT 549F AND 2235 PSIG.
51 1RC-414,415,*16 SE NLE FLOW Af ixE RE ACTOR COOLANT PIPE ELBOW HE T WE E N SG A OUTLE1 AND FEACIDW COOLANT PUMP RC-P-1A. REF: OP MANUAL CHAFTEk 6; LM whe-1; sM-406 3.
o
BEAVER VALLEY POWER STATION ERDS DATA POIN! Ll6RARV BV1 ERDS INPUT Date:
07/22/96 Renctor Unit:
BV1 Data Feeder:
Ipc NRC ERDS Parameter:
SG FRESS-1 A Point ID:
UO414 Plant Spec Point Desc..
$G A STM OUT FRESS 1/2/3 AVG Generic /Cond Desc.
STEAM GENERATOR A FRESSURE 4
Analog / Digital:
A Engr Units / Dig States:
PSIG Engr Units Conversion:
. I t.E AE Minimum Instr Range:
0 Maximum Instr Range:
1400 4
Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
P Number Of Sensors:
3 How processed:
SELIEVED VALUE ALGORITHM Sensor Locations:
SEE UN10UE SYSTEM DESCRIPTt0N FIELD Alarm / Trip Set Points:
H1 ALM @ 1400 PSIG/LO ALM s 600 FSIG NI Detector Power Supply Cut-off Power Level:
N/A N1 Detector Power Supply Turn-on Power Level:
N/A Instrument Failure Mode:
Luw Temperature Compensation for DP Transmit ters N
Level Reference Leg:
N/A Unique System Desc.
THis PO!NT FkOVIDES AN AVERACE OF THREE, TWO, OR A SINGLE STEAM F RE SSURE VALUE PEPENDING 0N THE DEVI ATION BETWEEN THE VALUES. THE ATMOSF*f 4 !C STE AM DUMP V AL VE S GPE N AT ID25 PSIG. THE MAIN STEAM f A F E V A'.',E S 6E 0!N LIFilNG AT 1C75 PSIG. PT MS 474, 475, 476 SENSE Main STEAM LINE PEEssukE BETWEEN inE MAIN STEAM TRIP VALVES AND SG a.
MANLAL (kAPTER 21, EM-421 1 i
e SE AVER VALLEY POWER ST A110N ERDS C ATA P0th! L!b4 ARY BV1 ERDS INPUT i
Date:
07/22/96 Reactor Unit BV1 Data Feeder:
C'JR E - F L JW2 Point ID:
UO420 Plant Spec Point Desc.
RCLB UNCORRECTED FLOW 1/2/3 AVG 1
Generic /Cond Desc.*
TOTAL kEACTOR COOLANT FLOW 1
Analog / Digital:
A l
Engr Units / Dig States:
Engr Units Conversion:
N/A i
Minimum Instr Range:
Maximum Instr Range:
120 Zero Point
Reference:
h/A 1
Reference Point Notes:
N/A PROC or SENS:
P Number Of Sensors:
3 How Processed:
BELIEVED VALLI ALGDRiinM I
Sensor Locations:
5EE UNiuuE Se viEM LE LLa!Pi!ON f! ELD Alarm / Trip Set Points:
wI ALM 7 120 r/LO ALM @ 92 %
NI Detector Power Supply Cut off Power Level:
h/A NI De;ector Power Supply Turn on Power Level:
N/A Instrument Failure Mode:
LOW Temperature Compensation For DP Transmitiers; h
Level Reference Leg:
>cA Unique System Desc.
SPCSFLOW 15 THE AVERAGE OF THREE, TWO OR A SINGLE FLOW VALUE DEPENDlhG ON inE DEVIATION BETWEEN FLOW slGNALS. RC P-1A, B, C EACH hAVE A DESIGN FLOW RATE OF 88,500 GPM AT 549F AND 2235 PSIC.
FT-10C-424,425,426 SENSE FLOW AT THE REACTOR COOLANT PIPE ELBOW EETWEEh SG B OUTLET AND RE ACTOR CDOLAhi PUMP RC-P-18. OP MANUAL Ca&rTER 6, RM-4D6 1, PM 406 3
e BEAVER VALLEY POWER STAfl0N ERDS DATA POINT LIBRARY BV1 ERDS INPUT Date:
07/22/96 Reactor Unit:
BV1 Data Feeder:
IPC NRC EROS Paraneter:
SG4 kE S5-28 Point ID:
00434 Plant Spec Point Desc.
SG B STM OUT PRESS 1/2/3 AVG Generic /Cond Desc..
STEAM GENERATOR B PRESSURE s
Analog / Digital:
A Engr Units / Dig States:
PSIG figr Units Conversion:
LINEAk Minimum inst r Range:
Maximum Instr Range:
1400 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
F Number Of Sensors:
5 How Processed:
hELIEVED VALUE ALCCRifMM Sensor Locations:
(EE UNIOUE SYSTEM DESCRIPiloh FIELD Alarm / Trip Set Points:
HI ALM G 1400 FSIG/LO ALM @ 600 PSIG 1
1 N1 Detector Power Supply Cut off Power Level:
N/A i
NI Detector Power Supply Turn on Power Level:
N/A Instrument Failure Mode:
LOW Temperature Compensation For DP Transmitters:
^
Level Reference Leg:
N/A Unique System DeSc.
IniS Fo1NT FROVIDES AN AVERAGE OF THREE, TWO, OR A SINGLE STEAM PRESSURE VALUE DEPENDING CN THE DEVI ATION BETWEEN THE VALUES. THE ATMOSP*ERIC STEAM Dump VALVE 5 OPEN AT 1025 PSIG. THE MAIN STEAM SAFETY VALVES BEGIN LIFilNG AT 1075 PSIC. PT-MS 484,485,486 SENSE M4th STEAM LINE PRESSURE EETWEEN THE MA!N STEAM TRIP VALVES AND SG
- h. DG wakuAL LeAptik 21, kM 421 1
e f
e BEAVER VALLEY POWER STATION ekDS uATA FOINT LIBRARY BV1 ERDS INPUT Date:
07/22/96 Reactor Unit:
BV1 i
l Data Feeder:
COEE FLUW3 i
Point 10:
00440 l
Plant Spec Point Desc.*
RCLC UNCORRECTED FLOW 1/2/3 AVG Generic /Cond Dese..
TOTAL REACTOR C00 LINT Flow Analog / Digital:
A Engr Units / Dig States:
x Engr Units Ccnversion:
N/A Minimum Instr Range:
u I
Hanimum Instr Range:
120 2ero Point
Reference:
N/A Reference Point Notes:
N/A 1
PROC or SENS:
P Number Of Sensors:
3 How Frocessed:
BEllEVED VALUE ALGORITHM Sensor Locations:
SEE UN!QUE SYS1EM OEstalPT!.A f! ELL Alarm / Trip Set Points:
wt ALM ? 120 t/ LOW ALM i 92:
NI Detector Power Supply Cut-off Power Level:
N/A N! Detector Power Supply Turn-on Power Level:
N/A Instrument Failure Mode:
Low Temperature Compensation For DP Transmitters:
A Level Ref erence Leg:
N/a Unique System Desc.
3 L t F L.w 15 Nt A=EkA J 05 THREE, TWO OR A SINGLE FLOW VALUE
'et ' tV! A T ICN BE TWEEN FLOW SIGNALS. RC P-1A,B,C EACH DEFEN0iNG GN s
HAVE A DE51GN riCW FATE OF E8,500 CPM AT 549F AND 2235 PSIG.
'6L-554,435,*36 SENSE FLOW AT THE REACTOR COOLANT PIPE ELBOW bEIwEEN SG C OUTLET AND REACTDP CDOLANT PUMP RC-P-1C. OP MANUAL CHASTER 6, RM 406-1, RM 406 3 3
e f
e SEAVER VALLEY power sTAliON EkDS DA1A Po!NT $1BRAkv BV1 EROS !NPUT Date:
07/??/06 Reactor Unit:
BV1 Data Feeder:
SG FRESS 3C Point 10:
UO454 Plant Spec Point Desc.
SG C SYM DUT PRESS 1/2/3 AVG Generic /Cond Desc.*
STEAM GENERATOR C PRESSURE Analog / Digital:
A Engr Units / Dig States:
PSIG Engr Unitn Conversion:
- !NEAR r.
Minimum Instr Range:
I j
Maximum instr Range:
1400 I
Zero Point Ref erence:
N/A Reference Point Notes:
N/A PROC or SENS:
P Number Of Sensors:
3 How Processed:
BEllEVED VALUE ALGokliHM Sensor Locations:
SEE UN13hE S$5f EM OESCR!rTION FIELD Alarm / Trip Set Peints:
wi ALM.e 1400 FSIG/LO ALM @ 600 PSIG N1 Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply Turn on Power Level:
N/A Instrument Failure Mode:
LOW Temperature Compensation For DP Transmitters:
s Level Ref e'ence Leg:
N/A Unique Syst em Desc.
IMIS IGINT kPOV!LE S AN AvEGAGE GF THREE, TWO, OR A SINGLE STEAM s*ESSukE VALUE LEFENDING ON THE DEVIATIJN BETWEEN THE VALUES. THE ATMOSPaERIC STEAM DUMP VALVES OPEN AT 1025 PSIG. THE MAIN STEAM 5AFETY VALVES SEGIN LIFTING AT 1075 PSIG. PT MS-494,495,496 SENSE MalN STEAM LINE FPESSunE EETWEEN THE MAIN STEAM TRIP VALVES AND SG LwAPTFG 21, RM 421 1 C. GP MANUA6
o o
BEAVER VALLEY POWER STATION ERDS DATA P0lNT LIBRARY BV1 ERDS thPUT 1
Date:
07/22/96 Reactor Unit:
Ov1 Data Feeder:
ExiRA10 Point ID:
UO472 Plant Spec Point Desc..
PRES $URIZER PRESS 1/2/3 AVG Generic /Cond Desc.
REACTO4 COOLANT SYSTEM PRESSURE Analog /Digitat:
A Engr Units / Dig States:
PSIG Engr Units Conversion:
N/A Minimun Instr Range:
1700 Maxinnsi instr Range:
2500 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
r Number Of Sensces:
3 How Processed:
BELIEVED VALUE ALGORITHM Sensor Locations:
5EE UN!QUE SYSTEM DESCRIPTION FIELD 1
Alarm / Trip Set Points:
N/A NI Detector Power Supply Cut-off Power Level:
N/A N1 Detector Power Supply Turn-on Power Levet:
N/A
)
Instrument failure Mode Low Tenperature Compensat iot, For DP Transmitters:
Level Ref erence Leg:
N/A Unique System Desc.
PZPERESS IS CDMPOSED OF 'HPEE PRES $URIZER PRESSURES, THE PO!NT CAN SE ikE AVER A02 OT THail. AVEEACE OF TWO OR A SINGLE VALUE DEPENDING DN YNE DEVl ATION OF VALUES.
e s
4 SEAVER VALLEY POWER STAil0N ERDS DATA PolNI LIBRARY j
'ivl F ELS input Date:
07/22/96 Reactor Unit:
is /1 Data Feeder:
PR2R-LEVEL Point ID:
U0483 Plant Spec Point Desc.'
P'.ESSURIZER LEVEL 1/2/3 AVG Generic /Cond Dese.
W! MARY SYSTEM kRESSURIZER L E VE L Analog / Digital:
A Engr Units / Dig States:
l Engr Units Conversion:
N/A Minimum Instr Range:
0 Maximum Instr Range:
100 l
i Zero Point Ref erence:
T' +w f R Reference Point Notes:
Si.E LNIQUE sf STEM LESCRIPi!DN FIELD PROC or SENS:
P Number Of Sensors:
3 How Processed:
BEllEVED VALUE POINT Sensor Locations:
SEE UNIOUE SYSTEM DESCRIPf!ON FIELD Alarm / Trip set Points:
at ALM @ 60 t/LO ALM @ 12 x N1 Detector Dower Supply Cut-of f Power Levet :
N/A NI Dete: tor Power Supply furn-on Power Level:
N/A Instrument Failure Mode:
LOW Temperature Compensation For DP Transmitters:
N Level Reference Leg:
N/A Unique System Desc.
PULEVEL CAh bE f ME A*/ERALE OF THKEE, TWO OR ONE LEVEL TRANSMITTER
- ! fMi. OEGENp;k. UN inE CEv!Af!DN BETWEEN VALUES. SEE ATTACHED X. i t s f. i ve edErsuel2Ek 0LUME IN GALLONS. LT 1RC-459, oL. ~61 SENSE PRE 55LR12ER LEVEL FROM 748' 1/4" (LOWER TRANSMITTER TAP) TO 781' 2 5/Pa (UFPER TRANSMITTER TAP). ZERO REF: MINIMUM WATER LEVEL 15 AT 752' 1 1/4" DR APPROX!MATELY 12%. REF: OP MWJAL CHAPTER 6; 8700-415.6A; 8700-6.24-Cl2821
e BEAVER VALLEY PCwfR STAllDN ERDS DATA POINT LIBRARY Bv1 ERDS INPUT Date:
07/22/96 Reactor Unit:
BV1 Data Feeder:
EXTRA 20 Point 10:
U1000 Plant Spec Point Desc.:
CONIAlhMENT PRESS 1/2/3 AVG Generic /Cond Desc.;
CONTAINMENT PRESSURE Analog /'s i g i t al :
A Engr Units / Dig States:
PSIA Engr Units Conversion:
N/A Minimum Instr Range:
5 Maximtsn Instr Range:
79 Zero Point
Reference:
N/A Reference Point Notes:
Nf.t PROC or SENS:
P Number Of Sensors:
3 How Proceoed:
BELIEVED VALUE ALGORifHM Sensor Locations:
siE uN!uuE SYSTEM DESCRIPfl0N FlELD Alarm / Trip Set Points:
NI ALM @ 14.7 PSIA /LO ALM @ 9.0 PSIA NI Detector Power Supply Cut-off Power Levet:
N/A NI Detecter Power Supply Turn on Power Level:
N/A Instrument failure Mode:
L O'.
Temperature Compensation For DP Transmitters:
N Level Reference Leg:
N/A Unique System Desc.*
U1000 RECE!VES INPUIS FROM ALL THREE PRESSURE TRANSMITTERS AND CAN 6E TaE A/ERALE OF i>REE, TWO, OR A SINGLE VALUE DEPENDING ON THE
- EvlAT104 CF sALUES. PT-1tM 100A, B, & C SENSE CONTAINMENT PRESSURE Af a 6 kissupf T AP LOCATED bETWEEN TV LM 100A1 AND A2 (CONTAINMENT ATt?N WAL '. i s ) AN; rogiAtygggy, op MANUAL CHAPTER 12
,v75 l
l 1
_ _ _ _ _ - ~ _. - _ _ _ _ _ _ _ _ _ _ - _ _ _ _. - _ _ _ _ _ -. _ _ _ _ _ _ _ _ - _ _ _ _ _
e e
d BEAVER VALLEY POWER STATION EROS DATA POINT LIBRARY BV1 ERDS INPUT Date:
07/22/06 Reactor Unit:
S/1 Data Feeder:
CTMNT TEMP Point ID:
U1008 Plant Spec Point Desc..
AVG OF 5 TS TEMPS Generic /Cond Desc..
CONTAINMENT TEMPERATURE Analog / Digital:
A Engr Units / Dig States:
DEG5 Engr Units Conversion:
=/A Minimum instr Range:
0 Maxinsmi instr Range:
300 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
P Number Of Sensors:
5 How Processed:
AVERAGE Sensor Locations:
SEE UNIQUE SYSTEM DESCRIPTION FIELD Alarm / Trip set Points:
HI ALM w 103 DEGF/LO ALM & 32 DEGF NI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply Turn-on Power Level:
N/A Instrument Failure Mode:
-itw Temperature Compensation For DP Transmitters:
N Levet Ref erence Leg:
N/A Unique f f stem Ce<c.
UJL80 15 THE AbEkACE OF AtL FivE TEMPERATURE INPUTS. T LM100-4 SENSES TEMPERATURE AT 7e4' th THE PRESSURIZER CUBICLE; T-LM100 7 LENSE 5 TEMPEE ATL'RE AT 797' ON f*E OPERATING FLDOR NE OF THE CRANE WALL; T-LM100-10 SENSES TEMPERATU&E AT 850' IN THE NNE CNMT DOME;
- ,M100 15 SENSEL 1EMPERATURE AT 730' !N THE SSE ANNULUS; LM 0u 16 sin 5ES TEMPEW Alo&E AT 701' 6" (N THE ENE ANNULUS. (SEE A'TACHED CWL.)
- _s_,
e 9
a
-s e
BEAVER VALLEY power STATION ERDS EAfA F0lki t!BRAEv BV1 FEDS INkot Date:
07/22'06 Reactor Unit:
b/l Data Feeder:
EXTRA 15 4
Pcint ID:
YO705A Plant Spec Point Desc.*
COMP COOLING /REClkC SPRAY Hx RW Generic /Cond Desc.*
AAD10ACTIVITV CF RELEASED L10UID Analog / Digital:
A Engr Un..s/ Dig States:
cpu Engr Units Conversion:
s/A Minimum Instr Range:-
10 Maxi nKm1 Instr Range:
I F. t>
Zero Point
Reference:
N/=
Reference Point Notes:
N/A PROC or $fNS:
A Number Of Sensors:
1 How Processed:
N/A Sensor Locations:
dEE UNIOUE SYSTEM DESCRIPTION FIELD Alarm / Trip Set Points:
ni ALM @ 1.81E4 CPM NI Detector Power Supply Cut-off Pcwer Level:
N/A j
NI Detector Power Supply Turn on Power Level:
N/A I ns t rument T w i t ure Mode:
Temperat;re Compensation For DP Transmitters:
N Level Ref erence Leg:
Nia unique System Desc.
'* - 1 k W 100 S AMF L E S F OR AC11VITY (CG 60 & CS-137) AT THE DISCHARGE U+
iaE sEACTOR CDMPONENT CDOLING WATER HEAT EXCHANGERS. FOLLOWING A CIB SIGNAL THE HMS! PUMP Dil COOLER AND THE RECIRC SPRAY HEAT EdC* ANGER DISCHARGE 15 AL50 MONITORED. HlCH ACTIVITV IS INDICATIVE OF A
- EAT ExcMANGER L(Am. A GAMMA SCINT!LLATION DETECTOR MONITORS
- ut!% ATEk/REclRC SPRAY HEAT EXCHANGERS.
ok MANuat CHA;!Ek 43, ku.33 3
0 a'
e e
e BEAVER VALLEV POWER STATION EROS DATA P0]NT LIBRARY BV1 ERDS INFUT Date:
07/22/96 Reactor Unit:
BV1 Data Feeder:
EFF-Liu "aD2 Point ID:
70717A Plant Spec Point Desc.*
LIQUID WASTE CONTAINMENT DN EFF Generic /Cond Desc.:
RADIOACTIVITY OF RELEASED LIQUID f
Analog / Digital:
A Engr Unitw/ Dig States:
CPM Engr Units Conversion:
N / t.
Minimum Instr Range:
10 Maximum Instr Range:
1E6 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
S Numoer of sensors:
1 How Processed:
N/A Sensor Locations:
SEE UN!QUE SYSTEM DESCRIPTION FIELD n
Alarm / Trip Set Points:
HI ALM @ 7,00E5 CPM j
NI Detector Power Supply Cut off Power Level:
N/A NI Detector Power Supply Turn-on Poner Level:
N/A Instrument Failure Mode:
LCL Temperature Cocoensation For DP Transmitters:
N Level Reference Leg:
N/A Unique System Desc.
wM 1LW 116 CONTINUOUSLY MONITORS THE ACTIVITY (C0 60 & CS 137) 0F r*E E FFLUENT DowNSTRE AM OF TrE LIQUID WASTE CONT AMINATED DRAINS FittEE. A H!Ce HlGM ACTivlTY WILL AUTOMATICALLY CLOSE THE ISOLAT10N VALVES TO TEaMINATE FLOW. A GAMMA SCINTILLAfl0N DETECTOR MONITDRS
- nE ACTlvliv Of LIQUID WASTE CONTAMINATED DRAINS EFFLUENT DowsSTEEAM OF fet rCNIAMINATED DGAINS flLTER. OP MANUAL CHAPTER 43, WM-417
- O s'
/
0 BEAVER VALLEY POWER STATION EROS CATA POINT LIBRARY BV1 Ek15 INPUT Date:
07/J2/0A Reactor Unit:
6vl Data Feeder:
EWTRA19 Point ID:
10735A Plant Spec Point Desc.
REACTOR CONTAINMENT L/R Generic /Cnnd Desc.
RADIATION LEVEL IN CONTAINMENT Analog / Digital:
A Engr Units / Dig States:
Mu/a#
Engr Units Conversion:
N/A Minimum Inf tr Range:
0,1 Maximum Instr Range:
10000 Zero Point
Reference:
N/A Ref erence Point Notes:
N/A PROC or SENS:
S Number Of Sensors:
1 How Procewsed:
N/A Sensor Locations:
SEE UNicuE SYSTEM DESCRIPTION FIELD Alarm / Trip Set Points:
H1 ALM @ 20.0 ME/NR N! Detector Power Supply Cut-off Pcwer Level:
N/A NI Detectcr Power Supply Turn on Power Level:
N'A Ins t runent failure Mode:
LOW Temperatur e Compensation For DP Transmitters:
N Level Ref erence Leg:
N/A l
Unique System Desc.
eM 1Rm 202 MONITORS TdE #ADI Af!ON LEVEL INSIDE CONTAINMENT AND WARNS PERSONNEL OF AN INCREASE :N THE RADIATION LEVEL. A l
GE IGER-MUELLER CETE,CTOR MONITORS R ADI ATION LEVEL INSIDE CONTAINMENT OF THE CRANE WALL DEPOS!!E THE PERSONNEL ACCESS. OP MANUAL CHAPTER 43 1
l l
l 1
1 1
.