Proposed Tech Specs 6.3 & 6.4 Re Requirements for Licensed Operator Qualifications & Training
ML20114D560
Person / Time
Site: Hope Creek 
Issue date: 09/01/1992
From:
Public Service Enterprise Group
To:
Shared Package
ML20114D549 List:
References
NUDOCS 9209090150
Download: ML20114D560 (3)


Text

--- t,

. y.,

, o_ -

ATTACIIMENT TECIINICAL SPECIF.TCATION PAGES WITil PEN AND INK CIIANGES

- SUPPIEMENT TO LICENSE APPLICATION 92-05, NLR-N92115 j

CIARIFICATION OF REQUIREMENTS FOR LICENSED 1

OPERATOR QUALIFICATIONS AND TRAINING I

The fellowing Technical Specifications have been revised to reflect the proposed changes:

Technical Specification pjggg 6.3.1 6-6 6.4.1 6-6 I

l-r lo l:

o I

i

. PJ' tJ.

' ADMINISTRATIVE CONTROLS _

6.2.3 SHIFT TECHNICAL ADVISOR 6.2.3.1 The Shift Technical Advisor shall provide advisory technical support to the Senior Nuclear Shift Supervisor in the areas of thermal hydraulics, reattor engineering, and plant analysis with regard to safe operation of the

unit, The Shift Technical Advisor shall have a bachelor's degree or equivalent in a scientific or engineering discipline and shall have received specific training in the response end analysis of the unit for trans'ents and accidents, and in unit design and lay at, including the capabilities oi instrumertation and controls in the controi roca.
6. 3 UNIT STAFF QUALIFICATIONS

. ggy 4 6.3.1 Each member of the unit staff shall meet or excee the minimum qualifi-cations of ANSI /ANS 3.1-1981 for comparable positions, e cept for the individual designated as.the Radiation Protection Manager who shal meet or exceed the P

+perators-and-54Mor Reactor-Openters shallualifications of Regulatory Guide 1.8, Septemb alte meet ar avceed the atnimum c

-qual 4f-ications-M-the-supplemntalanqui.remar,ts-spec 4&d in Ssctienc A-and 4

-ef inclosure 1 of --the3-g.MB--4980 NRC lettu-to-aM-McenseesJ 6.3.2 The Operations Manager, Operating Engineer, Senior Nuclear Shift Super-vi sor.'

and Nuclear Shift Suoervisors, shall holti a senior reactor operator license.

The Nuclear Control Operators shall hold a reactor operator license.

6.4 TRAINING 6.4.1 A retraining and replacement training program for the unit staff shal be maintained under the direction of the MarLger-Huclear Training,r.shall meet or exceed the requirements and recommendations of Section 5.5 of ANSI /ANS 3.1-1981gandpic CFR Pert-2f L2_)j l

INSERT B.

Instmr c.

6.4.2 A trahing program for the Fire Brigade shall be maintained under the direction of the Manager - Site Protection and shall meet or exceed the require-ments of the SRP (NUREG-0800) Section 13.2.2.11.6, 10 CFR 50 Appenoix R and Branch Technical Position CHEB 9.5,1, Section C.3.d.

,5,. 5 REVIEW AND AUDIT 6.5.1 STATION OPERATIONS REVIEW CCMMITTEE (SORC)

FUNCTION.

3 6.5.1,?

The 50RC shall function to advise the General Manager - Hope Creek UperaU cis on all matters related to nuclear safety.

HOPE CREEK 6-6 Amendment No. 52 l

y j

.1 x.

" Attachment.

NLR-N92115 Q

(Clazification of Operator Qualifications-and' Training LCR 92-05

INSERT-A
,andthoIlicensedoperatorswhoshallcomplywiththe requirements of 10CFR55 l-o
INSERT B-

.for all-affected positions except licensed operators,

' INSERT C r.

3); comply with-the requirements of.10CFR55 for licensed operators I

I l

l.

L i

L

=.

f I

L l[.

j' l.

L-..

Innert Page 1 of 1 I