Final Part 21 & Deficiency Rept,Item 110 Re Piston Skirt Castings on Tdi Emergency Diesel Engine Generator Sets. Initially Reported on 821216.New Ae Piston Skirts Awaiting Installation
ML20112F587
Person / Time
Site: Harris 
Issue date: 12/12/1984
From: Parsons R
CAROLINA POWER & LIGHT CO.
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
CON-NRC-303, REF-PT21-84, REF-PT21-85-015-000 110, PT21-85-015-000, PT21-85-15, NUDOCS 8501150425
Download: ML20112F587 (4)


Text

_ -.

h l?

Carolina Power & Light Company P. O ox 1ew i 1,

. 27562 December 12,1984 Mr. James P. O'Reilly NRC-303 United States Nuclear Regulatory Commission Region II 101 Marietta Street, Northwest (Suite 2900)

Atlanta, Georgia 30323 CAROLINA POWER & LIGHT COMPANY SHEARON HARRIS NUCLEAR POWER PLANT 1986 - 900,000 KW - UNIT I POTENTIAL DEFECT IN PISTON SKIRT CASTINGS ON THE EMERGENCY DIESEL-ENGINE GENERATOR SETS PURCHASE ORDER NY-435079, ITEM 110

Dear Mr. O'Reilly:

Attached is our final report on the subject item which was deemed reportable per the provisions of 10CFR50.55(e) and 10CFR, Part 21, on December 16, 1982. With this report, Carolina Power & Light Company considers this matter closed.

If you have any questions regarding this matter, please do not hesitate to contact me.

Yours very truly, 7/7 R. M. Parsons Project General Manager Completion Assurance Shearon Harris Nuclear Power Plant RMP/sae

~ Attachment cc: ' Messrs. G. Maxwell /R. Prevatte (NRC-SHNPP)

. Mr. R. C. DeYoung (NRC) k$$dbP 8501150425 841212

/

PDR ADOCK 05000400 S

PDR f, /gg

/

CAROLINA POWER & LIGHT COMPANY SHEARON HARRIS NUCLEAR POWER PLANT UNIT NO. I t:

FINAL REPORT

- EMERGENCY DIESEL-ENGINE GENERATOR SETS POTENTIALLY DEFECTIVE "AN" PISTON SKIRTS

. DECEMBER 12,1984

^

~

, ITEM 110 h

,m 9

REPORTABLE'fUNDER 10 FR50 55(e) AND 10CFR21 2

,p".

[Q y '

e a~

d v.

~

r:-

e Y

(

SUBJECT:

Shearon Harris Nuclear Power Plant Unit N o.

I 10CFR50.55(e) and 10CFR21 Reportable Deficiency.

Potentially defective piston skirts for the Emergency Diesel-

= Engine Generator Sets. Purchase Order NY-435079.

. ITEM:

Piston skirts installed in the piston assembly of the emergency diesel-engine generator sets: S/N 74046/47.

SUPPLIED B_Y_:

Transamerica DeLaval, Inc., Oakland, California under CP&L Y

Purchase Order NY-435079.

. NATURE OF

- DEFICIENCY:'

Transamerice DeLaval, Inc., shipped two diesel engines to the Shearon Harris site in May and June,1981.

In November,1982, Transamerica DeLaval notified CP&L that the ' engines have a potential problem with the "AN" piston skirts. Residual stress caused by the method of heat treating in combination with operating stress could cause cracking of the piston skirt during operation and, if undetected, could result in engine failure.

- DATE PROBLEM

' OCCURRED:

Refer to section above.

> +

- DATE PROBLEM'-

REPORTED:

Dec. ember 16,' 1982, CP&L- (N. 3. Chiangi) notified the NRC '

s (C. Hehl) that this item is reportable under the provisions of' 10CFR50.55(e) and 10CFR21.

SCOPE OF PROBLEli:

This potential defect exists with "AN" piston skirts. Both.

emergency diesel engines purchased on NY-435079 had-"AN"-

- piston skirts..

iSAFETY IMPLICATION:

The diesel-engine ' generator. sets supply power to the ESF

. buses in the event that both normal on-site and. off-site i

~ ' '

power sources are lost.

o, The.potentialidefect in the piston skirts could affect engine.

operation cand,. therefore, affect the' availability of.

emergency on-site power.

9 f /4 g

4 ~-

%e n.5W

7 0

e l

REASON DEFICIENCY IS REPORTABLE:

If left uncorrected, cracking of the piston skirts could result in the loss of the emergency on-site AC power supply.

CORRECTIVE ACTION:

The potentially defective "AN" piston skirts were removed from the engines and sent to Transamerica DeLaval. New "AE" piston skirts are now on site awaiting Installation.

Installation will be accomplished in accordance with revised procedures which incorporate the new "AE" piston skirts.

j I

k Z

6

.- 6 m'

P P