Amends 27 & 16 to Licenses NPR-10 & NPF-15,respectively, Changing Tech Spec 3.4.1.4.1 to Allow Removal of Both Trains of Shutdown Cooling in Mode 5,if One Reactor Coolant Pump in Operation & Both Coolant Loops Operable
ML20108D162
Person / Time
Site: San Onofre  
(NPF-10-A-027, NPF-10-A-27, NPF-15-A-016, NPF-15-A-16)
Issue date: 11/09/1984
From: Knighton G
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20108D165 List:
References
TAC-51616, TAC-51617, NUDOCS 8412110303
Download: ML20108D162 (12)


Text

T<

4, 4

SOUTHERN CALIFORNIA EDISON COMPANY

-SAN DIEGO GAS AND ELECTRIC COMPANY THE CITY OF RIVERSIDE, CALIFORNIA-THE CITY OF ANAHEIM, CALIFORNIA DOCKET NO. 50-361 SAN ONOFRE NUCLEAR GENERATING STATION, UNIT 2 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 27 License No. NPF-10 1.

The Nuclear Regulatory Comission (the Comission) has found that:

A.,1TheIapp'licationsforamendmenttothelicenseforSanOnofreNuclear Generating Station, Unit 2 (the facility) filed by the Southern California Edison Company on behalf of itself and-San Diego Gas and

Electric Company, The City of Riverside and The City of Anaheim',-

California (licensees) dated September 3, 1982 and January 25, 1983 comply with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act) and the Comission's regulations as set forth in 10 CFR Chapter I; B.

. The-f'acility will operate in conformity with the applications, as 4

amended, the provisions of the Act, and the regulations of the.

~

Comission; l

C.'

'There is reasonable assurance:

(1) that the activities authorized l

by this amendment can be conducted without' endangering the health.

.and safety of'the public, and (ii) that such activities will be i

conducted in compliance with the Comission's regulations set-forth 4

in 10 CFR Chapter..I; I

D.

The issuance of this license amendment will not be inimical to the

.comon defense and security or to the health and safety of. the public;.

.s f

j 2

O L

P l

7.--

- E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

2.

Accordingly, the license is amended by changes to the Technical Specifica-tions as indicated in the attachment to this license amendment, and paragraph 2.C(2) of Facility Operating License No. NPF-10 is hereby amended to read as follows:

(2) Technical Specifications The Technical Specifications contained in Appendix A and the Environ-mental Protection Plan contained in Appendix B, as revised through Amendmant No. 27, are hereby incorporated in the license.

SCE shall operate the facility in accordance with the Technical Specifications and the Environmental Protection Plan.

3.

This amendment is effective as of the date of issuance.

FOR THE NUCLEAR REGULATORY COMMISSION O

George W. Knighton, Chief Licensing Branch No. 3 Division of Licensing

Attachment:

Changes to the Technical Specifications Date of Issuance: November 9, 1984 OELD.c]ler

$lka LB#3 B#3 LCha'ri GWRnighton HRood/yt 10/\\1/84 10

/84 10/#/84 M/ f/84

//

i l-

F s

November 9, 1984

. ATTACHMENT TO LICENSE AMENDMENT NO. 27 FACILITY OPERATING LICENSE NO.'NPF_10 DOCKET NO. 50-361 Replace the following pages of the Appendix A Technical Specifications with the enclosed pages. The revised pages are identified by Amendnent number and.

contain vertical lines indicating the area of change. Also to be replaced is the following reissued page.

Amendment Pages Reissued Page 3/4 4-5 3/4 4-Sa 3/4 4-6 9

~

REACTOR COOLANT SYSTEM COLD SHUTDOWN - LOOPS FILLED LIMITING C0hDITION FOR OPERATION 3.4.1.4.1 a.

At least one of the following loop (s)/ trains listed below shall be OPERABLE and in operation *:

1.

Reactor Coolant Loop 1 and its associated steam generator and at least one associated Reactor Coolant Pump **

2.

Reactor Coolant Loop 2 and its associated steam generator and at least one associated Reactor Coolant-Pump **

3.

Shutdown Cooling Train A 4.

Shutdown Cooling Train B b.

One additional Reactor Coolant Loop / shutdown cooling train shall be OPERABLE, or c.

The secondary side water level of each steam generator shall be greater than,10% (wide range).

APPLICABILITY:

MODE 5, with Reactor Coolant loops filled.

ACTION:

a.

With less than the above required shutdown trains / loops OPERABLE or with less than the required steam generator level, immediately initiate corrective action to return the required trains / loops to OPERABLE status or restore the required level as soon as possible.

t b.

With no loop / train in operation, suspend all operations involving a reduction in boron concentration of the Reactor Coolant System and immediately initiate corrective action to return the required loop /

train to operation.

  • All reactor coolant pumps and shutdown cooling pumps may be de-energized for up to I hour provided (1) no operations are permitted that would cause dilution of the Reactor Coolant System boron concentration, and (2) core outlet temperature is maintained at least 10*F below saturation temperature.

SAN ONOFRE - UNIT 2 3/4 4-5 AMENDMENT N0. 27 i-

REACTOR COOLANT SYSTEM COLD SHUTDOWN - LOOPS FILLED

' SURVEILLANCE REQUIREMENTS 4.4.1.4.1.1 The required Reactor Cooling pump (s), if not in operation, shall be determined to be OPERABLE once per 7 days by verifying correct breaker align-

~

ments and indicated power availability.

4.4.1.4.1.2 The required steam generator (s) shall be determined OPERABLE by verifying the secondary side water level to be >10% (wide range) at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

4.4.1.4.1.3 At least one Reactor Coolant loop or shutdown cooling train shall be verified to be in operation and circulating Reactor Coolant at least once -

per 12' hours.

4 1

i

~

SAN ONOFRE - UNIT 2 3/4 4-Sa

' AMENDMENT N0. 27

~ REACTOR COOLANT SY' STEM COLO SHUT 00WN --LOOPS NOT FILLED LIMITING CONDITION FOR OPERATION 3.4.1.4.2 Two shutdown cooling trains shall be OPERABLE # and at least one shutdown ccoling train shall be in operation."

t APPLICABILITY:

MCDE 5 with Reactor Coolant loops not filled.

I ACTION:

With less than the above required trains OPERABLE, immediately a.

initiate corrective action to return the required trains to OPERABLE status as soon as possible.

With no shutdown cooling trains in operation, suspend all operations b.

involving a reduction in boron concentration of the Reactor Coolant System and immediately initiate corrective action to return the required shutdown cooling train to operation.

(

SL*RVEILLANCE REQUIREMENTS At least one shutdown cooling train shall be determined to be in 4.4.1.4.2 operation and circulating reactor coolant at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

  1. ne shutdown cooling train may be inoperable for up to 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> for surveillance 0testing provided the other shutdown cooling train is OPERABLE and in operation.

The shutdown cooling pump may be de-energized for up to 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> provided 1) no

=

operations are permitted that would cause dilution of the Reactor Coolant System boron concentration, and 2) core outlet temperature is maintained at least 10*F below saturation temperature.

(

SAN ONOFRE-UNIT 2 3/4 4-6 AMEt:0 MENT NO. 16

4

.p.

" q [

(

+,

~

. w(

s t.

SO'THERN-CALIFORNIA EDISON COMPANY U

-e SAN DIEGO GAS AND ELECTRIC COMPANY THE CITY OF' RIVERSIDE, CALIFORNIA THE CITY OF ANAHEIM.' CALIFORNIA DOCKET NO. 50-362 SAN ON0FRE NUCLEAR GENERATING STATION, UNIT 3 AMENDMENT TO FACILITY OPERATING LICENSE Ame'ndment No.16 License No. NPF-15

.s

1. -The Nuclear Regulatory Commission (the Consission) has found that:

A.

The applications for amendment to the license for San Onofre Nuclear Generating Station, Unit 3-(the facility). filed by the Southern California Edison Company on behalf of itself and San Diego' Gas and.

California-(pany, The City of Riverside and The City of Anaheim, Electric Com licensees) dated September 3, 1982 and January 25, 1983 comply with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act) and the Commission's regulations as set forth in 10 CFR Chapter I;

~

B.

- The facility will operate in conformity with the applications, as amended, the provisions of the Act, and the regulations of the Commission; C.

There is reasonable assurance:

(1) that the activities authorized by this amendment can be conducted without endangering the health

'and safety of the public, and (ii) that such activities will be

-conducted in compliance with the Commission's regulations set forth in 10 CFR Chapter'I; D.

The issuance of this license amendment will not be inimical to thet common-defense and security or to the htalth and safety of the public;

[

1

(

e 9

h

7_

l m.

W

' E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

2.

Accordingly, the license is amended by changes to the Technical Specifica-tions as indicated in the attachment to this license amendment, and paragraph 2.C(2) of Facility Operating License No. NPF-15 is hereby amended to read as follows:

(2) Technical Specifications The Technical Specifications contained in Appendix A and the Environ-mental Protection Plan contained in Appendix 2, as revised through Amendment No.16, are hereby incorporated in the license. SCE shall operate the facility in accordance with the Technical Specifications and the Environmental Protection Plan.

3.

This amendment is effective as of the date of issuance.

FOR THE NUCLEAR REGULATORY COMMISSION George W. Knighton, Chief Licensing Branch No. 3 Division of Licensing

Attachment:

Changes to the Technical Specifications Date of Issuance: November 9, 1984 DL 3

  1. 3 OELQ /
l #M HRood/yt LChdfi er Kron 10/p/84

.10

/84 10/)[/84

(/84

//

Nsvemb:r 9, 1984

. ATTACliMENT TO LICENSE AMENDMENT NO.16 FACILITY OPERATING LICENSE N0. NPF-15 DOCKET tiO. 50-361 Replace the following pages of the Appendix A Technical Specifications with the enclosed pages. The revised pages are identified by Amendment number and contain vertical lines indicating the area of change. Also to be replaced is the following reissued page.

Amendment Pages Reissued Page 3/4 4-5 3/4 4-Sa 3/4 4-6 4

1 i

REACTOR COOLANT SYSTEM COLD SHUTDOWN - LOOPS FILLED LIMITING CONDITION FOR OPERATION 3.4.1.4.1

a.

At least one of the following loop (s)/ trains listed below shall be OPERABLE and in operation *:

1.

Reactor Coolant. Loop 1 and its associated steam generator and at least one associated Reactor Coolant Pump **

2.

Reactor Coolant Loop 2 and its associated steam generator and at least one associated Reactor Coolant Pump **

3.

Shutdown Cooling Train A 4.

Shutdown Cooling Train 8 b.

One additional Reactor Coolant Loop / shutdown cooling train shall be OPERABLE, or c.

The secondary side water level of each steam generator shall be greater than 10% (wide range).

APPLICABILITY: MODE 5, with Reactor Coolant loops filled.

ACTTON:

a.

With less than the above required shutdown trains / loops OPERABLE or with less than the required steam generator level, immediately initiate corrective action to return the required trains / loops to OPERABLE status or restore the required level as soon as possible, b.

With no 1 cop / train in operation, suspend all operations involving a reduction in boron concentration of the Reactor Coolant System and immediately initiate corrective action to return the required loop /

train to operation.

  • All reactor coolant pumps and shutdown cooling pumps may be de-energized for up to I hour provided (1) no operations are permitted that would cause dilution of the Reactor Coolant System boron concentration, and (2) core outlet temperature is maintained at least IC*F below saturation temperature.

SAN ONOFRE - UNIT 3 3/4 4-5 AMENDMENT NO. 16

3

' REACTOR COOLANT-SYSTEM COLD SHUTDOWN - LOOPS FILLED SURVEILLANCE REQUIREMENTS 4.4.1.4.1.1 The required Reactor Cooling pump (s), if not in operation, shall' be determined to be OPERABLE once per 7 deys' by verifying correct breaker align-ments and indicated power availability.

4.4.1.4.1.'2 The required steam generator (s) shall be determined OPERABLE by verifying the secondary side water level to be >10% (wide range) at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

4.4.1.4.1.3 At least one Reactor Coolant loop or shutdown cooling train shall be verified to be in operation and circulating deactor Coolant at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

SAN ONOFRE - UNIT 3 3/4 4-Sa AMEN 0 MENT NO. 16

REACTOR COOLANT SYSTEM i

COLD SHUTDOWN - LOOPS NOT FILLED LIMITING CONDITION FOR OPERATION 3.4.1.4.2 Two shutdown cooling trains shall be OPERABLE and at least one shutdown cooling train shall be in operation."

APPLICABILITY:

MODE 5 with Reactor Coolant loops not filled.

ACTION:

a.

With less than the above required trains OPERABLE, immediately initiate corrective action to return the required trains to OPERABLE status as soon as possible.

b.

With no shutdown cooling trains in operation, suspend all operations involving a reduction in boron concentration of the Reactor Coolant System and immediately initiate corrective action to return the required shutdown cooling train to operation.

(

SURVEILLANCE REQUIREMENTS 4.4.1.4.2 At least one shutdown cooling train shall be determined to be in operation and circulating reactor coolant at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

  1. ne shutdown cooling train may be inoperable for up to 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> for surveillance 0

testing provided the other shutdown cooling train is OPERABLE and in operation.

AThe shutdown cooling pump may be de-energized for up to 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> provided 1) no operations are permitted that would cause dilution of the Reactor Coolant System boron concentration, and 2) core outlet temperature is maintained at least 10*F below saturation temperature.

\\

SAN ONOFRE-UNIT 3 3/4 4-6