Forwards Addl Info Re Local Leak Rate Tests for Valves & Penetrations & Improvements for Local Leak Rate Test Program
ML20106E365
Person / Time
Site: Brunswick 
Issue date: 10/22/1984
From: Zimmerman S
CAROLINA POWER & LIGHT CO.
To: Vassallo D
Office of Nuclear Reactor Regulation
References
NLS-84-455, NUDOCS 8410290188
Download: ML20106E365 (22)


Text

-

4 CD&L Carolina Power & Light Company.

SERIAL: NLS-84-455 0CT 2 21984 Director of Nuclear Reactor Regulation Attention:

Mr. D. B. Vassallo, Chief

/

Operating Reactors Branch No. 2 Division' of Licensing

(

United States Nuclear Regulatory Commission Washington, DC 20555 BRUNSWICK STEAM ELECTRIC PLANT, UNIT NO. 1 DOCKET NO. 50-325/ LICENSE NO. DPR-71 REQUEST FOR ADDITIONAL INFORMATION UNIT 1 LOCAL LEAK RATE TESTS

Dear Mr. Vassallo:

As a ' result of. telephone conversations with your staff, Carolina Power & Light Company committed to provide additional information concerning our submittal of September 4,1984 which requested a one-time only deferment of requiral Type B ami C local leak rate tests (LLRTs) for certain valves and penetrations.

Specifically, the following data was requested :

1)

The previous LLRT results for the subject valves.

2)-

An indication of which valves can be testal during plant operation.

3).

The approximate dose received during valve testing.

This information has been compiled ami is provided in Attachment 1.

The dose rates listed in Attachment 1 are for testing performed while shutdown, dose rates encountered while testing at power would be substantially higher.

Aiditionally, although many 'of these tests may be performed at power (as indicatal), most would require placing the system in a limiting condition for operation action statement or would initiate a half scram. We consider such actions to be a greater safety concern than deferral of the LLRT testing for three months. provides additional information regarding programmatic improvements at Brunswick involving the LLRT program.

Should you have further uestions concerning this matter, please contact Mr. John S. Dietrich at 919) 836-6154.

Yours very truly, Ohf0

::='

P S.

.immerman Manager Nuclear Licensing Section MAT /pgp (766 MAT) cc:

Mr. D. O. Myers (NRC-BNP)

-Mr. J. P. O'Reilly (NRC-RII)

Mr. M. Grotenhuis (NRC) 411 Fayetteville Street

  • P O Box 1551
  • Raleigh. N C. 27602 l \\

~

o.

Attachment I to Serial:

NLS-84-455 O

8 I

TEST TEST TEST RESULTS APPROXIMATE NO.

VALVES unta (wen)

TEST AT POWER (?)

DOSE EXPENDITURE E-1 Electrical Pene X100A 12-12-82 0

YES 0.02 man-rem 07-21-82 0

02-05-80 0

01-15-79 0

E-2 Electrical Pene X1008 12-12-82 0

YES 0.02 man-rem 07-21-82 0

02-05-80 0

01-15-79 0

E-3 Electrical Pene X100C 12-12-82 0

YES 0.02 man-rem 07-21-82 0

02-05-80 0

01-15-79 0

E-4 Electrical Pene 1100D 12-12-82 0

YES 0.02 man-res 07-21-82 0

02-08-80 0

01-15-79 0

E-5 Electrical Pene X100E 12-14-82 0

YES 0.02 man-rea 07-22-82 0

02-08-80 0

01-18-79 0

E-6 Electrical Pene X100F 12-14-82 0

YES 0.02 man-rea 07-22-82 0

02-08-80 0

01-18-79 0

E-7 Electrical Pene X100G 12-14-82 0

YES 0.02 man-rea 07-21-82 0

02-08-80 0

01-18-79 0

a TEST' TEST TEST RESULTS APPROXIMATE NO.

VALVES DATE (SCFil)

TEST AT POWER (?)

DOSE EXPENDITURE E-8 Electrical Pene X100H 12-14-82 0

YES 0.02 man-rea 07-22-82 0

02-08-80 0

01-18-79 0

E-9 Electrical Pene X101A 12-13-82 0

YES 0.02 man-rea 07-21-82 0

02-08-80 0.25 01-16-79 0

E-10 Electrical Pene X101C 12-13-82 0

YES 0.02 man-rea 07-21-82 0

02-07-80 0

01-16-79 0

E-Il Electrical Pene X101D 12-18-82 O

YES 0.02 man-ren 07-21-82 0

l 02-11-80 0

1 01-15-79 0

1 4

E-12 Electrical Pene X101F 12-18-82 0

YES 0.02 man-rem j

07-22-82 0

1 02-11-80 0

l 01-15-79 0

)

E-13 Electrical Pene X102A 12-13-82 0

YES 0.02 man-rem j

07-21-82 0

02-05-80 0

01-15-79 0

l E-14 Electrical Pene X102B 12-13-82 0

YES 0.02 man-ren l

07-21-82 0

02-06-80 0

]

01-16-79 0

i E-15 Electrical Pene X102C 12-14-82 0

YES 0.02 man-rem 4

07-22-82 0

02-08-80 0

i 01-16-79 0

=.7 TEST TEST TEST RESULTS-APPROXIMATE NO.

VALVES DATE (scru)

TEST AT POWER (?)

DOSE EXPENDITURE E-16 Electrical Pene X102E 12-14-82 0

YES 0.02 man-res 07-22-82 0

02-08-80 0

01-17-79 0

E-17 Electrical Pene X102F 12-14-82 0

YES 0.02 man-res 07-21-82 0

02-08-80 0

01-18-79 0

E-18 Electrical Pene X102H 12-18-82 0

YES 0.02 man-rea 07-21-82 0

02-05-80 0.21 01-18-79 0

E-19 Electrical Pene X103A 12-13-82 0

YES 0.02 man-rea 07-21-82 0

02-05-80 0.21 01-16-79 0

E-20 Electrical Pene X1038 12-16-82 0

YES 0.02 man-rem 07-21-82 0

02-08-80 0

01-18-79 0.77 E-21 Electrical Pene X104A 12-13-82 0

YES 0.02 man-rea 07-21-82 0

02-05-80 0

01-16-79 0

E-22 Electrical Pene X104B 12-13-82 0

YES 0.02 man-rea 07-21-82 0

02-06-80 0

01-16-79 0

E-23 Electrical Pene X104C 12-14-82 0

YES 0.02 man-rea 07-22-82 0

02-08-80 0

01-16-79 0

e

m TEST TEST TEST RESULTS APPROX 1 MATE NO.

VALVES ImTE (suru)

TEST AT POWER (?)

DOSE EXPENDITURE E-24 Electrical Pene X104E 12-14-82 0

YES 0.02 man-res 07-22-82 0

02-08-80 0

01-17-79 0

E-25 Electrical Pene X104F 12-16-82 0

YES 0.02 man-rea 07-22-82 0

02-08-80 0

01-18-79 0

E-26 Electrical Pene X104G 12-18-82 0

YES 0.02 man-ren 07-21-82 0

02-08-80 0

01-18-79 0

E-27 Electrical Pene X105B 12-12-82 0

YES 0.02 man-rem 07-21-82 0

02-05-80 0.04 01-15-79 1.438 E-28 Electrical Pene X105C 12-12-82 0

YES 0.02 man-ren 07-21-82 0

02-05-80 0

01-16-79 0

E-29 Electrical Pene X105D 12-14-82 0

YES 0.02 man-res 07-21-82 0

02-08-80 0

01-16-79 0

E-30 Electrical Pene X105E 12-13-82 0

YES 0.02 man-res 07-21-82 0

02-07-80 0

01-16-79 0.67 E-31 Electrical Pene X105G 12-14-82 0

YES 0.02 man-rea 07-22-82 0

02-08-80 0

01-16-79 1.54

TEST TEST TEST EESULTS AFFROKIMATE NO, VALVES DaTr.

M enJ TEST AT POWER (?)

DOSE EIFENDITURE E-32' Electrical Pene 1105H 12-14-82 0

YES 0.02 man-res 07-22-82 0

02-08-80 0

01-17-79 0

E-33 Electrical Pene 1105J 12-18-82 0

YES 0.02 man-res 07-21-82 0

02-11-80 0

01-17-79 0

E-34 Electrical Pene 1105K 12-18-82 0

YES 0.02 man-res 07-22-82 0

02-11-80 0

01-17-79 0

E-35 Electrical Pene X232E 12-18-82 0

YES 0.02 man-res 07-22-82

'O 02-11-80 0

01-19-79 0

E-36 Electrical Pene 1232C 12-18-82 0

YES 0.02 man-res 07-22-82 0

02-11-80 0

01-19-79 0

H2 Personnel Inck to 01-19-83 0

YES 0.02 man-rea Drywell Liner Seal 10-13-81 0

04-10-79 0

M2 CAC V5 Inboard 0-Rings 12-31-82 0

YES 0.125 man-res 09-14-82 0

06-23-81 0

03-26-79 0

M3 CAC V6 Inboard 0-Rings 12-31-82 0

YES 0.1 man-res 09-14-82 0

06-23-81 0

03-26-79 0

i TEST TEST TEST RESULTS APPROEIM&TE N00 VALVES

.DATE (an.ruJ TEST AT POWER (?)

DOSE EEPENDITURE M4 CAC V7 Inboard 0-Rings 02-21-83 0

YES 0.125 man-res j

09-12-82 0

j 09-11-82 0.199 4

09-06-82 lar(1) 1 08-31-82 0

05-09-81 0

03-26-79 0

j MS CAC V9 Inboard 0-Rings 12-23-82 0

YES 0.1 man-rem 08-31-82 0

j 05-22-81 0

1 03-26-79 0

3 M6 CAC V16 Inboard 0-Rings 12-26-82 0

TES 0.125 man-rem i

09-07-82 0

~

04-20-81 0

02-02-79 0

l i

M7 CAC V17 Inboard 0-Rings 03-14-83 0

YES 0.125 man-res 09-01-82 0

)

06-22-81 0

7 02-12-79 0

j B21-2 B21-F010B 01-12-83 0

NO (Feedwater System 0.562 man-ren

]

07-31-82 1.785 in service) 07-25-82 WWF(2) 06-27-80 0.04 j

04-06-79 7.97 i

B21-3 R21-F032A, E41-F006 03-17-83 5.457(3)

NO (Feedwater System 0.02 man-rem 03-03-83 0

in service) 05-01-81 0.479

}

02-23-79 4.016 I

  • WNP = Would Not Pressurize (1) Remove valve and repaired imperfections in sealing surface, 1-M-82-2588 1

l (2) Cleaned valves 1-M-82-208, MI-16-525, and MI-16-583

.- (3) Repacked valve E41-F006 per 1-M-82-1553

TEST TEST TEST RESULTS

-APPROXIMATE N00 VALVES DATE

( m,rm)

TEST AT POWER (?)

DOSE EXPENDITURE B21-4 B21-F0325, E51-F013, 03-03-83 0.749(1)

NO (Feedwater System 0.02 man-rem G31-F039 01-14-83 WMP in service) 06-26-81 14.76 04-08-79 2.889 CAC-1 CAC V47 12-31-82 0

NO (Located inside 0.1 man-rem 09-21-82 0

torus) 09-05-82 0

05-06-81 0

06-07-80 0

03-13-79 4.0 CAC-2 CAC V48 12-30-82 0.550 NO (Located inside 0.562 man-res 09-21-82 0.7225 drywell) 09-14-82 0

04-30-81 0

0~r-01-79 0

CAC-4 CAC V7, V8, V22 02-22-83 5.457(2)

YES (SBCT in LCO) 0.125 man-res 01-04-83 10.11 09-12-82 0

09-06-82 0

09-06-82 WNP 08-31-82 UNP 08-15-82 WNP 05-09-81 6.368 04-23-81 WNP(3) 03-01-79 1.51 CAC-5 CAC V9, VIO, V23 12-23-82 2.348 NO (Neutron dosage) 0.1 man-ren 09-03-82 2.702 08-31-82 3.037 08-29-82 5.85 08-24-82 2.790 05-21-81 2.462 05-02-81 WNP(4) 04-07-79 1.323

  • WNP = Would Not Pressurize (1) Repacked valve B21-F0328 per 1-M-82-1705

(2) Rebuilt valves,1-M-83-268 and 1-M-83-234 -

(3) Rebuilt valve, 1-N-81-lO77 (V7)

TEST TEST TEST RESULTS APPROKIMATE NO.

VALVES DATE

. (wru)

TEST AT POWER (?)

DOSE EXPENDITURE CAC-6 oCAC X20A, V16 12-26-82 0.738 YES 0.125 man-ren 09-07-82 0'

09-06-82 WNP(1) 09-02-82 WNP(2) 05-28-81 2.376 04-20-81 WNP(3) 04-02-79 2.06 1

CAC-7 CAC X20B, V17 12-26-82 0

YES 0.125 man-ren 09-01-82 0-i 06-22-81 1.72 04-20-81 WNP(4) 04-05-79 24.21 CAC-9 CAC-PV-12005 12-16-82 0

YES 0.02 man-ren 07-26-82 0

(31-day LCO) 04-10-80 0

01-31-79 0

CAC-10 CAC-PV-1261 12-16-82 0

YES 0.02 man-res 07-26-82 0

(31, day LCO) 04-10-80 0

01-31-79 0

t CAC-11 CAC-PV-1227A 12-14-82 0

NO (Located inside 0.562 man-ren 1

08-31-82 0

drywell) 10-14-80 0.60 02-15-79 0

1 1

}

CAC-12 CAC-PV-12278 12-14-82 0

NO (Located insLie 0.562 man-rem 08-13-82 0

drywell)

?

10-14-80 0.60 3

02-16-79 0

  • WNP = Would Not Pressurize

~

(1) Replaced seal on vacuum breaker, 1-M-82-2589 (2) Operations cycled valve (3) Replaced valve seal (V16),1-M-81-1057 l

(4:) Replaced seal (V17), 1-M-81-1058, and set stroke and limit switches, 1-E-81-1246 1

3 t.

TEST TEST TEST IRSULTS APPROXIMATE-P'-

NO.

VALVES mars 4wru;

, TEST AT POWEE(?)

DOSE EXPENDITURE 1.

1 CAC-14 CAC-PV-1227E 12-15-82 0

YES-

' O.'02 man-ren 10-09-82

'0

-(31-day LCO) 07-25-82 0.068 06-02-80 0.246 02-15-79 0

r i

i CAC-15 CAC-PV-1260 12-15-82 0

YES 0.02 man-ren 07-25-82 0.0912 (31 day LCO) 06-02-80 0.246 02-16-79 0

i

^

CAC-16 CAC-PV-1231B 12-14-82 0

NO (Locates insLie 0.01 man-ren i

08-13-82 0.6021 torus) 10-14-80 0.148 3

01-26-79 0

{

CAC-17 CAC-PV-3440 12-15-82 0

YES 0.02 man-ren I

07-18-82 0

(31, day LCO) e j

12-15-79 0

CAC-18 CAC-PV-1225B 12-15-82 0

YES 0.02 man-ren i

07-18-82 0.353

.1-day LCO) 02-15-79 0

k

~

I CAC-19 CAC-PV-1211F 12-14-82 0

YES 0.02 man-res r

i 07-26-82 0

(31, day LOO) 1 06-02-80 0.372 01-29-79 0

I t

CAC-20 CAC-PV-1262 12-14-82 0

YES 0.02 man-res 07-26-82 0

(31, day LCO) 06-02-80 0.478 02-14-79 0

1 l

CAC-21 CAC-PV-1209A 12-13-82 0

NO (Located inside 0.0562 man-ren 08-14-82 0

drywell) 1 10-28-80 0.385 i

01-30-79 0

1 l

~,

TEST TEST TEST RESULTS APPROXIMATE NO.

VALVES DaTs (scru)

TEST AT POWER (?)

DOSE EXPENDITURE CAC-22 CAC-PV-1209B 12-13-82 0

NO (Located inside 0.0562 man-res 08-14-82 0

d rywell) 10-28-80 0.385 01-29-79 0

CAC-23 CAC-PV-1205E 12-13-82 0

NO (Located inside 0.0562 man-res 08-14-82 0

d rywell) 11-04-80 0.385 01-29-79 0

CAC-24 CAC-PV-1215E 12-14-82 0

NO (Located inside 0.01 man-rea 08-13-82 0

torus) 11-04-80 0.385 01-29-79 0

i CAC-25 CAC-PV-1211E 12-14-82 0

YES 0.02 man-ren 07-18-82 0

(31mday LCO) 02-14-79 0

i CAC-26 CAC-PV-3439 12-14-82 0

YES 0.02 man-rea 07-18-82 0

(31, day LCO) 02-14-79 0

4 CAC-39 CAC-PV-1218C 12-16-82 0

YES 0.125 man-ren i

07-19-82 0

(31, day LCO)

CAC-40 CAC-PV-1219B 12-20-82 0

YES 0.02 man-rea 07-19-82 0

(half-scram)

CAC-41 CAC-PV-1225C 12-18-82 0

YES 0.02 man-ren 07-19-82 0

(talf-scram)

CAC-42 CAC-PV-1209D 12-18-82 0

YES 0.02 man-rea 07-19-82 0

(half-scram) i CAC-45 CAC-PV-1219C 12-17-82 0

YES 0.02 man-rem j

07-19-82 0

(31, day LCO)

~

i~

TEST TEST' TEST RESULTS APPROXIMATE NO.

VALVES uars (surnJ TEST AT POWER (?)

DOSE EXPENDITURE E11-1 E11-F008, F009 03-23-83 0

NO (RHR suction) 0.1 man-rem 03-10-83 0(1) 3 08-23-82 0

06-02-81 0

03-10-79 0.747 j

i E11-2 E11-F011A 03-28-83 0

YES (RER in sevenmday 0.125 man-rom l

07-27-82 0

LCO [A loop])

05-27-80 8.18 01-19-79 0-i i

E11-3 E11-F0118 12-30-82 5.552 YES (RHR B loop in 0.125 man-ren 05-19-81 13.302 seven, day LCO) j 05-14-81 WNP 05-04-81 WNP(2) 1 03-11-79 8.966 i

E11-4 Ell-F015A, F017A 03-08-83 2.16(3)

NO (Reactor vessel at 0.1 man-ren 1

02-01-83 0.748 pressure) 08-23-82 3.775 07-27-82

.882 1

i 06-03 0.907 03-27-79 0

E11-5 E11-F0158, F017B 01-24-83 0

NO (Reactor vessel at 0.1 man-rem 08-23-82 4.967 pressure) 05-12-81 11.903 1

05-04-81 14.5(4) l 02-26-79 0

  • WNP = Would Not Pressurize (1) Rebuilt valve, IM-83-728 (Ell-F009) j (2) Set stroke (LVF0538), 1-E-81-1279 (3) Repack Valve, IM-82-2053 (F017A) j (4) Set stroke (E11-F0178), 1-E-81-1212 i

i t

1 4

TEST TEST TEST RESULTS APPROXIMATE NO.

VALVES 7TE -

(scru)

TEST AT POWER (?)

DOSE EXPENDITURE i

E11-6 E11-F016A, F021A 03-26-83 O(1)

YES (kHR A loop in 0.02 man-ren 02-01-83 0.253 seven day LCO) 07-27-82 0.8242 06-02-80 3.65 03-27-79 0

Ell-8 E11-F020A 03-29-83 13.598(2)

YES (RHR A loop in 0,125 man-res 02-03-83 WNP seven-day LCO) 07-29-82 12.826 07-28-82 WNP 05-30-80 18.21

?

01-18-79 0

E11-11 E11-F024A, F027A, 02-02-83 0

YES (RHR A loop in 0.125 man-ren F028A 07-27-82 0

seven, day LCO) 05-28-80 0.374 03-27-79 0.8 4

E11-12 Ell-F0248, F027B, 01-28-83 0(3)

YES (RHR B loop in 0.125 man-ren F028B 01-25-83 0

neven, day LCO) 05-04-81 0

03-07-79 0.75 s

E11-13 E11-F025A 02-04-83 0

YES 0.02 man-res 07-27-82 0

06-30-80 0

j 03-28-79 0

E11-14 Ell-F025B 01-17-83 0

YES 0.02 man-res 07-19-82 0

03-10-79 0.747 E11-15 E11-F037D 12-22-82 0.1 YES 0.02 man-res 07-18-82 0

(half-scram)

CWNP = Would Not Pressurize (1) Rsplaced Stem, IM-83-331 (F016A) l (2) Replaced Stem, IM-83-344 (3)- Rsplaced Bonnet Gasket, IM-82-2818 (F0288)

TEST TEST TEST RESULTS APPROXIMATE NO.

VALVES DATY.

( 5GFtt)

TEST AT POWER (?)

DOSE EXPENDITURE E11-16 E11-F0378 12-16-82 0

YES 0.02 man-res 07-18-82 0

(half-scram)

E11-17 E11-F043D 12-22-82 0.1 YES 0.02 man-res 07-18-82

'O (half-scram)

E11-19 E11-F037C 12-16-82 0

YES 0.02 man-ren 07-18-82 0

(half-scram)

E11-20 E11-F043C 12-16-82 0

YES 0.02 man-rea 07-18-82 0

(half-scram)

E11-22 E11-F037A 12-16-82 0

YES 0.02 man-res 07-18-82 1.150 (half-scram) 6 E11-23 E11-F097 01-11-83 0(1)

YES 0.02 man-ren 12-30-82 34.43 08-03-82 0.3781 E11-24 E11-F007A 02-01-83 0

YES (RHR A loop in 0.125 man-rea 08-10-82 0.061 seven, day LCO)

E11-25 E11-F007B 01-28-83 0(2)

YES (RHR B loop in 0.125 man-ren 01-21-83 23.02 seven day LCO) 08-11-82 0

E11-26 E11-F103A 02-02-83 0

NO (Both loops tie in) 0.07 man-ren 08-16-82 0

E11-27 E11-F103B 01-18-83 0

NO (Both loops tie in) 0.07 man-res 08-13-82 0

E11-28 E11-F055A 02-04-83 0

NO (Tie into HPCI ard 0.07 man-ren 08-16-82 0.2735 B loop RHR) 08-13-82 0.714

?

(1,) Replaced Gasket, IM-83-0061 394Kb

1 TEST TEST TEST RESULTS APPROXIMATE-NO.

VALVES DATE (5UFR)

TEST AT POWER (7)

DOSE EXPENDITURE i

E11-F0558 01-05-83 0.398 NO (Tie into HPCI' and 0.07 man-ren Ell-29 08-14-82 0.6530 A loop RER)

Ell-30 E11-V20 02-04-83 0

NO (Common loop tie-in) 0.07 man-rea 08-25-82 0.0608 j

08-20-82 0

t Ell-31 E11-V21 01-05-83 0

NO (Common loop tie-in) 0.07 man-ren 08-19-82 0.1654 Ell-32 E11-F029 02-22-83 0

NO (RHR suction) 0.125 man-rem i

08-20-82 0.555 l

E21-1 E21-F001A 02-21-83 3.608 YES (Core spray A loop 0.125 man-ren i

04-22-81 0

in seven, day LCO) 1 02-05-79 0.81 j

E21-2 E21-F001B 12-29-82 0.106 YES (Core spray B loop 0.125 man-rem 07-26-82 0

in seven, day LCO) 06-04-80 0.316 e

02-07-79 0

i 02-05-79 0.81 E21-3 E21-F004A, F005A 02-18-83 0

NO (Reactor vessel 0.125 man-ren 02-26-82 0

under pressure) 04-23-81 0

01-30-79 0

i E21-4 E21-F004E, F005B 12-23-82 0.168 NO (Reactor vessel 0.125 man-ren i

08-24-82.

2.962 under pressure)

{

06-04-80 0

i 04-29-81

- 0 j

01-30-79 0

E21-5 E21-F015A 02-21-83 0

YES (Core spray A 0.125 man-rea 07-28-82 0.8219 loop in seven, day LCO) 06-02-80 2.823 02-01-79 0

2

\\:

1 1

i

TEST TEST

~ TEST RESULTS APPROXIMATE No.

VALVES DATE (SCFH)

TEST AT POWER (?)

DOSE EXPENDITURE E21-6 E21-P015B 12-29-82 0

YES (Core spray B 0.125 man-res 07-25-82 0

loop in seven, day LOO) l 06-23-80 1.78 i

05-27-80 WNP(1) 02-01-79 0

E21-7 E21-F031A 02-21-83 0

YES_(Core spray A' O.125 man-res 04-21-81 0

loop in seren, day LCO) l 07-26-79 0

i E21-8 E21-F031B 01-19-83 0

YES (Core spray B 0.125 man-ren 02-24-82 0.2822 loop in seren, day LCO) 06-03-80 0.039 01-26-79 0

E41-1 E41-F002, F003 03-22-63 O

NO (Reactor vessel 0.125 man-ren i

08-04-82 0.8223 under pressure) 07-25-82 WNP i

07-22-82 WNP(2) 01-19-82 WNP(3) 06-03-80 2.653 4

01-17-79 0

l E41-2 E41-F012 12-19-82 0

YES (HPCI in 14, day 0.125 man-rem i

07-28-82 4.174 LCO) 06-01-80 0.03 01-17-79 0

i E41-3 E41-F042 12-19-82 0

YES (HPCI in 14, day 0.125 man-ren 07-22-82 1.139 LCO) 1 i

06-30-80 5.9307 l

06-02-80 WNP(4) 01-13-79 0

l (WNP = Would Not Pressurize (1) Reset torque switch j

(2) Repacked ani disassembled,1-M-82-2081 i-j (3) Lapped seat, new pressure seal gasket, 1-E-83-321, 1135, 696, M-82-3148, 1-M-82-3197

(.4) Relapped seat (E41-F049)

TEST TEST RESULTS APPROXIMATE TEST

. VALVES unrs (surn)

TEST AT POWER (?)

DOSE EXPENDITURE NO.

E41-4 E41-F022, F040 02-10-83 0

YES (HPCI in 14, day 0.125 man-rea 07-22-82 0

LCO) 06-10-80 0

03-16-79 0.60 E41-6 E41-F075, F079 12-19-82 0

YES (HPCI in 14 day 0.125 man-rea 07-22-82 1.090 LCO) 06-06-80 1.9974 01-19-79 0

E41-7 E41-PV-1218D, 1220D 12-28-82 0

YES (HPCI in 14, day 0.125 man-rea 07-20-82 0

LCO) 07-19-82 WNP(l)

E41-8 E41-PV-1219D, 1221D 02-18-83 0

YES (HPCI in 14, day 0.125 man-rea 07-18-82 0

LCO)

E51-2 E51-F019 12-17-82 0

YES (RCIC in 31, day 0.125 man-rem 07-22-82 0

LCO) 03-08-79 0

E51-3 E51-F031 12-16-82 0

YES (RCIC in 31, day 0.125 man-ree 07-22-82 0

LCO) 06-05-80 0

01-18-79 0

E51-4 E51-F002, F028 02-04-83 0

YES (RCIC in 31 day 0.125 man-rea 07-18-82 0

LCO) 07-18-82 9.552(2) 06-06-80 0

01-17-79 0

  • WNP = Woudd Not Pressurize (1) Tightened bonnet (2) Cleanad valve and replaced gasket (F028), 1-M-82-2005 s

e

TEST TEST TEST RESULTS APPROXIMATE NO.

VALVES DATE

( SCFH).

TEST AT POWER (7)

DOSE EKPENDITURE G16-1 G16-F003, P004 01-28-83 0

YES 0.125 man-ren 09-26-82 9.1361 09-06-82 WNP 09-04-82 WNP 08-31-82 WNP 08-29-82 WNP 05-28-80 0.307 02-07-79 0

C16-2 G16-F019, F020 01-27-83 0.7531 YES 0.125 man-rea 08-01-82 2.532 07-15-82 WNP(1) 05-28-80 0.0218 04-03-79 2.797 G31-2 G31-F042 03-11-83 0

NO (System under 0.02 man-rea 08-12-82 0

pressure (1000 lbs)

SA-1 SA-V448 03-23-83 0

NO (Located insLie 0.093 man-rem 04-29-81 0

d rywell)

SA-2 SA-V449 03-23-83 0

YES 0.02 man-rem 04-30-81 0.076 TIP-1 TIP-VI 12-17-82 0

NO (Located insLde 0.225 man-ren 07-19-82 0

d rywell) 01-22-79 0

TIP-2 TIP-V2 12-17-82 0

NO (Located inside 0.225 man-rem 07-19-82 0

d rywell) 01-22-79 0

TIP-3 TIP-V3 12-17-82 0

NO (Located inside 0.225 man-rea 07-19-82 0

d rywell) i 01-22-79 0

(WNP = Would Not Pressurize J

(1) Cleaned valve and set stroke (F019),1-M-82-2083

~.

TEST

'. TEST TEST RESULTS APPROXIMATE NO.

VALVES DATE

.(5UFM)

TEST AT POWER (?)

DOSE EXPENDITURE TIP-4 TIP-V4 12-17-82 0

NO (Located insMe 0.225 man-res 07-19-82 0

d rywell) '

01-22-79 0

TIP-5 TIP N2 Check Valve 12-17-82 0

NO (Locatal insMe 0.225 man-res 07-18-82 0

d rywell) 01-22-79 0

TIP-6 TIP N2 SolenoM Valve 12-17-82 0

YES 0.02 man-ren 07-18-82 0

03-26-79 0

4 I

l-i k

i 9

to Serial: NLS-84-455 O

.g.

Summary of LLRT Program Improvements

- Expanded total ISI staff from two to ten people with three solely dedicated to LLRT/ILRT.

- Significantly revised program in 1982 following an extensive review of containment penetrations to incluie a larger number of tests.

- Require performance of prenaintenance LLRTs to determine "as found" containment leakage to more closely monitor valve degradation and overall

, containment integrity.

- Revised maintenance procedures to ensure the requirements for pre-and postmaintenance LLRTs are determined correctly.

- Leakage trends since 1982 (these values are approximate):

Unit 1 Unit 2 1982 120 scfh 145 refh 1983 90 scfh 120 sefh 4

1984 90 scfh*

90 scfh 1

  • Not a complete cycle for data; Unit I has basically been at power throsqghout 1984.

- For clarification:

BSEP performs its ILRT at 49 psig and the pass / fail limit is 0.5% wt/ day (L The.375 L is used as the criteria for determining whether the,)LRTs remain a,t the 40-month interval or the shorter r

I 18-month interval.

4

.