Cp&L Caroli ower & Light Company P. O. Box 165, New Hill, Nort t.

ina 27562 January 17, 1985 FILE: SH N-2/18 MQAH 85-24 Item 196 Mr. James P.'O'Reilly Urlted States Nuclear Regulatory Commission Region II

-Suite 2900 101 Marietta Street, NW Atlanta, Georgia 30323 SHEARON HARRIS NUCLEAR POWER PLANT, UNIT NO. 1 DOCKET NO. 50-400 HYDROGEN ANALYZER CABINETS - WELD DEFICIENCIES

Dear Mr. O'Reilly:

This is to confirm the January 17, 1985 telephone conversation between Mr. N. J. Chiangi (CP&L) and Mr. A. Hardin.

Mr. Hardin was informed that the December 20, 1984 potentially reportable item, pertaining to the weld deficiencies identified during receipt inspection of hydrogen analyzer cabinets, has been evaluated and considered not to be reportable per the provisions of 10CFR50.55(e).

Thank you for your consideration in this matter.

.]

Yours very truly, NJC/mt cc:

Mr. R. C. DeYoung N. J. Ch ngi - Manager Mr. G. Maxwell Quality Ass a ce/ Quality Control Mr. R. L. Prevatte Harris Plant oo TOEN 850go o

o g

S 1