Text

.

4 Attachment A NPF-39-123 9204300376 920424 PDR ADOCK 05000382 P.

PDR

.~

PLANT SYSTEMS MAIN STEAM LINE ISOLATION VALVES LIMITING CONDITION F00. OPERATION 0

3.7.1.5 Each main steam line isolation valve shall be OPERABLE.

APPLICABILITY:

H0 DES 1, 2, 3, and 4.

ACTION:

H00E 1 9

With one main steam line isolation valve inoperable but open, POWER OPERATION may continue provided the inoperable valve is restored to OPERABLE status within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />; otherwise, be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

MODES 2, 3 and 4 With one main steam line isolation valve inoperable, subsequent operation in H00E 2, 3, or 4 may proceed provided:

a.

The isolation valve is maintained closed.

b.

The provisions of Specification 3.0.4 are not applicable.

Otherwise, be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

SURVEILLANCE REQUIREME415 4.7.1.5 Each main steam line isolation valva shall be demonstrated OPERABLE by verifying full closure within 3.0 seconds when tested pursuant to Specification 4.0. 5.

b VATERFORD - UNIT 3 3/4 7-9

TABLE 3.3-5 (Continued)

ENGINEERED SAFETY FEATURES RESPONSE TIMES INITIATING SIGNAL AND FUNCTION RESPONSE TIME IN SECONOS 2.

Pressurizer Pressure-Low a.

Safety injection (ECCS)

(1) High Pressure Safety Inje:ction 1 30.0*/18.5**

(2) Low Pressure Safety Injection 1 45.5*/34.0**

- I b.

Containment Isolation 5 23.5*/12.0**

c.

Containment Cooling

$ 31.0*/h.5**

3.

Coatainment Pressure-Hich a.

Safety Injection (ECCS)

(1) High Pressure Safety Injection 1 30.0*/18.5**

(2) Low Pressure Safety Injection 1 45.5*/34.0**

b.

Containment Isolation

< 23.5*/12.0**

c.

Main Steam Isolation

~

4.0*/4.0**

d.

Main Feedwater Isolation

[6.0*/6.0**

Containment Cooling 5 31.0*/19.5**

e.

4.

LContainment Pressure--High-High a.

Conta;nment Spray Pump i 15.2*/2.7**

b.

Containment-Spray Valves c.

CCW to RCP Valves-1 11.0*/1L 0**

1 23.5*/12.0**

5.

Containment Area _ Radiation-Hinh#

Containment Purge Valves Isolation 5 6.2*/6.2**

6.

Steam Generator Dressure-Low 4.

Main Steam Isolation 5 4.0*/4.0**

n.

Main Feedwater Isolation 5 6.0*/6.0**

7.

Refuelina Water Storace-Pool.L..ow.

-Containment Sump _ Recirculation i 120.0*/108.58*

G.

W16 kV Emergency Bus-Undervoltace (Loss of Voltace)

.Less of Power (0_ volts)

_ 2***

9.

480V Emergency Bus Undervoltage-(Loss of-Voltagej Loss'of Power (0 'olts)

N.A.

10, 4.16 kV Emeroency Bus undervoltace (Deciaded Voltage)

Loss of Power

-< 11***

WATERFORD - UNIT'3 3/4 3-23

-**4 W

w

=t

'lp-.c w

t.rY-m A s-Wg 9ier er r*

e "#

  • 'Fly=

r-

W

{gPt-9w'3

" T

. - -.. - -... - _ - ~.-.. --- - -. - - - - -.. - -...... -. -.. - -. -. -

V E

e i

t F

k Attachment B NPF-38-123 1 <

I F

3 1

I 1

6 ll.

1 t...

_. -., _. ~.. - -. _, _.... - _ -.. -..

..,. -.....,,..,_..~..,._- _ _ _

~ ~..

~.. -. ~ - - -

. - - ~ ~. -.. -

)

PLANT SYSTEMS HAIN STEAM LINE ISOLATIO'l VALVES I

LIMITING CONDITION FOR OPERATION J

o 3.7.1.5 Each main steam line isolation valve shall be OPERABLE.

APPLICABILITY: MODES 1, 2, 3, and 4.

ACTION:

H00E 1.

With one main steam line isolation valve inoperable but open, POWER OPERATION may continue provided the inoperable valve is restored to OPErtABLE status within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />; otherwise, be in at least HOT STANDBY within the next G hours.

MODES 2, 3, and 4

-With one main steam line isolation valve ino9erable, subsequent operation in H0DE 2. 3, or 4 may proceed provided:

a.

The isolation valve is maintained closed.

b.

The provisiv.ts of Specification 3.0.4 are not applicable.

Otherwise, be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD. SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

SURVEILLLCE REQUlHEMENTS 4.7.1.5 Each main steam line isolation valve shall be demonstrated OPERABLE by verifying full closure within seconds when tested pursuant to Speci fication 4.0.5.

a REPLhlE VYlTH 4.0 oi:

I L

WATERFORD - UNIT 3 3/4 7-9 L

2

_~.

u

O' i

TABLE 3.3-5 (Continued)

{

ENGINEERED SAFETY FEATURES RESPONSE TIMES l

INITIATING 5:GNAL AND FUNCTION RESPONSE TTME IN SECONOS 2.

Pressurizer Dressure-tow a.

Safety Injection (ECCS)

(1) High Pressure Safety injection 5 30.0*/18.5**

(2) Low Prtssure Safety Injection 5 45.5*/34.0**

h.

Containment Isolation

< 23.5*/12.0**

c.

Containment Cooling i 31.C*/19.5**

3.

Containment Pressure-Hinn a.

Safety Injection (ECCS)

(1) High Pressure Safety Injection 1 30 0*/18.S**

(2) Low Pressure Safety Iajection 5 45.5*/34.0**

b.

Containment Isolation

< 23.5*/12.0** I~)Sfi# 4CE 4.0 c,

Main Steam Isolation

[i4.0^/4.0t*__;

WilH 50 d.

Main Feedwater Isolation 1 6.0*/6.0**

e.

Containment Cocling

$ 31.0*/19.5**

4.

Containment Pressure--Hign-High a.

Containment Spray Pump

< 15.2*/2.7**

b.

Containesnt Spray Valves 511.0*/11.0**

c.

CCW to RCP Valves 1 23.5a/12.0**

5.

-Containment Area Radiatior-Hloh#

Containment Purge Val'.es Isolation 1 6.2*/6.2**

}REPL ACE 4,0 Steam Generator Pressure-Low WITH 5.0 a.

Main Steam Isolation 5 _4. 0 * /4. 0 "

o.

Main Feedwater Isolation i 6.0*/6.0**

7.

Refueling Water Storage Pool Low Containment Sump Recirculation 5 120.0*/108.5**

8.

4.16 kV Emergency Bus Undervoltage (Loss of Voltage)

Loss of Power (0 volts)

,2***

9.

480V-Emergency Bus Undervoltage (Loss of Voltage)-

^

Loss of Power (0 volts)

N.A.

10.

4.16 kV creroency Bus undervoltage (Degraded Voltage)

Loss of Power

_ 11***

WATERFORD - UNIT 3 3/4 3-23