OPERATIONAL QUALITY ASSURANCE MANUAL t
INTRODUCTION This Manual describes the Operational Quality Assurance Program established to assure that nucleC,m,ver plants are operated ia accordance with applicable regulatory requirements and in a manner which protects the public health and safety.
The Operational Quality Assurance Program conforms to the criteria established in Appendix B to 10CFR50, " Quality Assurance Criteria for Nuclear Power Plants and Fuel Reprocessing Plants," and to the Regulatory Position in applicable NRC Regulatory Guides and industry standards as delineated in Appendix A to this Manual.
Guidance in the preparation of this Manual was obtained from the NRC's " Standard Review Flan" (NUREG-0800, formerly NUREG-75/087).
The Quality Assurance Program described herein is applicable to the Grand Gulf Nuclear Station (GGNS), and is referenced in Section 17.2 of the Vadated Final Safety Analysis Report.
The program applies to all operational plase activi-ties that affect the safety-related functions of those structures, systems and l11 components to prevent or mitigate the consequences of postulated accidents that could cause undue risk to the health and safety of the public.
9206150129 920610 PDR ADOCK 05000416 P
PDR Page 1 of 1
.ntroduction Rev. 11 OQAMR11.8/SQPFLR
OPERATIONAL QUALITY ASSURANCE MANUAL FOREWORD This Manual prescribes the Operational Quality Assurance Program Policies to control operational phase safety-related activities for the Grand Gulf Nuclear Station.
The program described in these Policies complies with the require-ments of Appendix B to 10CFR50 and incorporates appropriate provisions of applicable industry standards and NRC Regulatory Guides, as delineated in Appendix A to this Manual.
Compliance with the requirements set forth in this Manual is mandatory for all personnel involved in safety-related activities for the Grand Gulf Nuclear Station.
Copies of this Manual are numbered for control and will be kept up-to-date by the issuance of revisions, as necessary.
TheDirector,Qualityisresponsiblel11 for control of the Manual and issuance of revisions.
The holders of the Manual are responsible for keeping their copy current by appropriately handling revisions.
3 OQAMR11.B/SOPFLR
OPERATIONAL QUAllTY ASSURANCE MANUAL TABLE OF CONTENTS POLICY TITLE REV.
Policy 1 Organization 11 Policy 2 Quality Assurance Program 11 Policy 3 Design Control 11 Policy 4 Procurement Document Control 11 Policy 5 Instructions, Procedures and Drawings 11 Policy 6 Document Control 11 Policy 7 Control of Purchased Material, Equipment 11 and Services Po' icy 8 Identification and Control of Matet al, Parts 11 and Components Policy 9 Control of Special Processes 11 Policy 10 Inspection 11 Policy 11 Test Control 11 Policy 12 Control of Measuring and Test Equipment 11
(
Policy 13 Handling, Storage and Shipping 11 Policy 14 Inspection, Test and Operating Status 11 Policy 15 Nonconforming Materials, Parts or Components 11 Policy 16 Corrective Action 11 Policy 17 Quality Assurance Records 11 Policy 18 Audits 11 Appendix A Conformance of GGNS Operational Quality 11 Assurance Program to NRC Regulatory Guides and ANSI Standards Appendix B Document Control Responsibility for Quality 11 Related Documents Appendix C Operational Quality Assurance Program 11 Implementing Procedures Page 1 of 1 Table of Contents Rev. 11 0QAMRll.8/SQPFLR
g
-0PERATIONAL QUALITY ASSURANCE MANUAL TITLE:- ORGANIZATION-1.0 ORGANIZATION
_1.1 _ PURPOSE This Policy _ describes the organizations and key personnel responsible for developing, implementing and verifying the effectiveness of the Operational Quality Assurance Program for the Grand Gulf Nuclear Station.
1.2 SCOPE
-This Policy defines the organizational structure and delineates the authority, responsibility and lines of communication for organizations performing functions covered by the Operational Quality Assurance Program.
Certain of these functions may be delegated to other qualified
~
organizations, but responsibility for the program is retained and exercised by the licensee.
1.3 ORGANIZATION AND RESPONSIBILITY Clear and definitive lines of authority, responsibility and communication are established for all licensee organizations involved in the Operational Quality Assurance Program.
These lines extend from the highest management level through intermediate levels to and including _the onsite operating organization and offsite organizational elements.
The organizational structure and functional responsibility assignments are such that attainment of program objectives is accomplished by those who_have been assigned responsibility for performing the work, and verification of conformance to established requirements is accomplished by qualified personnel who do not have responsibility for performing or directly supervising the work.
Organizational structure and lines of authority, responsibility and communication are depicted in the organizational charts included at the end of this Policy. The dashed line between the Director, Quality, and
-the Chairman & Chief Executive Officer indicates guidance on Quality-Assurance policy matters and a direct escalation path.
The dashed line from the. Manager, Quality,_to the Chairman and Chief Executive Officer indicates guidance on matters related to quality.
1.3.1 Chairman & Chief Executive Officer 11 Ultimate responsibility for providing top level direction of all activities associated'with the safe and reliable operation of the Grand Gulf Nuclear Station rests with the Chairman &
Chief Executive Officer of the Company. The Chairman & Chief Executive Officer provides' guidance with regard to corporate-quality assurance policy. He delegates authority and responsi-bility for the development, implecentation and verification of=
the Operational Quality Assurance Program to the appropriate Page 1 of 15 Policy 1 Rev. 11 0QAMR11.B/SQPFLR
OPERATIONAL QUALITY ASSURANCE MANUAL TITLE: ORGANIZATION
1.3.1 (Continued)
organizations through the President and Chief Operating Officer, the Senior Vice President, Planning & Assurance and the Vice President, Administrative Services and Regulatory Affairs and the Vice President, legal and External Affairs. He Il maintains a continuing awareness of quality assurance matters and monitors effectiveness of the program through status reports prepared by the Director, Quality and the Manager, Quality.
1.3.2 Vice President, Operations GGNS The Vice President, Operations GGNS reports directly to the President and Chief Operating Officer and is responsible for l 11
~
the administration of all functions associated with the operation of the Grand Gulf Nuclear Station, except those delegated to the Vice President, Engineering, the Vice President, Administrative Services and Regulatory Affairs, The Vice President, Operations Support, and the Senior Vice President, Planning & Assurance.
He is also responsible for training.
He provides guidance with regard to quality assurance goals and objectives to the Director, Quality.
He l 11 maintains a continuing awareness of quality matters through applicable reports and management audits of the program, it is the Vice President, Operations GGNS' responsibility to assure that the requirements of the Operational Quality Assurance Program are implemented by the organizations under his direction.
1.3.3 Director, Quality _
The Director, Quality reports directly to the Vice President, Operations GGNS and is delegated the overall authority and responsibility for establishing, controlling and verifying the implementation and adequacy of the Operational Quality 11 Assurance Program.
This includes the establishment of quality assurance policies, goals and objectives.
He is assisted by the Manager, Quality Services and the Manager, Quality Systems.
The primary duties and responsibilities of the Director, Quali-ty include:
1.3.3.1 Developing and controlling the Operational Quality Assurance Program and the content of this Manual, including the approval of changes thereto and provid-ing for interpretations thereof; 1.3.3.2 Directing the activities of the Quality Programs' Staff in verifying the implementation of the Operational Quality Assurance Program.
Page 2 of 15 Policy 1 Rev. 11 OQAMRll.B/SQPFLR
OPERATIONAL QUALITY ASSURANCE MANUAL TITLE:
ORGANIZATION l'.3.3 (Continued):
1.3.3.3 Reporting to the Vice President, Operations GGNS and the Chairman & Chief Executive Officer on the status 11 and adequacy of the Operational Quality Assurance Program; 1.3.3.4 Reviewing and approving Quality Assurance Procedurc3; 1.3.3.5 Providing for review of and concurrence with documents as specified in Appendix B of this Manual; 1.3.3.6 Providing for the planning, scheduling and coordinating of training for the Quality Programs Staff; providing quality assurance input to the training and indoctrination programs for personnel performing quality-related activities; and providing for the approval of all Quality Programs Staff certifications.
1.3.3.7 Maintaining adequate communications with regulatory agencies, suppliers, contractors and other licensee organizations on quality assurance matters; 1.3.3.8 This section deleted in Revision 4.
1.3.3.9 Planning and performing receipt inspections; 1.3.3.10 Developing and carrying out an audit program, as described in Policy 18.0 of this Manual, to verify conformance with Operational Quality Assurance Program requirements; 1.3.3.11-Providing for periodic review and analysis of NRC and licensee quality deficiency documents to detect possible adverse quality trends.
1.3.3.12 Providing for inspections and nondestructive examinations.
1.3.3.13 Providing for the coordination, development and issuance of quality assurance reports as required by Management and appropriate procedures.
1.3.3.14 Providing for the coordination and/or implementation of administrative services for Quality Programs.
The Director, Quality is independent of undue influences and resaonsibilities for schedules and costs, and has sufficient autlority and organizational freedom to identify quality problems, recommend solutions and verify implementation of 11 solutions.
If acceptable solutions cannot be reached he has the responsibility and authority to escalate these matters to the Chairman & Chief Executive Officer.
He has the authority, 00AMR11.8/SQPFLR
OPERATIONAL QUALITY ASSURANCE MANUAL TITLE: ORGANIZATION
~
1.3.3 (Continued)
as delineated in the appropriate Quality Assurance Procedure, to initiate action to stop unsatisfactory work and control fur-
-ther processing, delivery, or installation of nonconforming items or continuation of nonconforming services pending correc-tion of the nonconforming condition.
i 1.3.4 Manager. Quality Services The Manager, Quality Services reports directly to the Director, Quality.
He directs Quality Programs' staff in inspections, 11 nondestructive examination, receipt inspections, procurement document reviews, and reviews of activities to verify implementation of the Operational Quality Assurance Program.
The Manager, Quality Services has the authority to initiate action to stop unsatisfactory work and control further processing, delivery or installation of nonconforming items or continuation of nonconforming services pending correction of the nonconforming condition.
The primary duties and responsibilities of the Manager, Quality Services include:
-1.3.4.1
~ Coordinating the review of procedures, as delineated in Appendix 8 to this manual to assure quality re-quirements are addressed.
1.3.4.2 Developing, interpreting and maintaining the Operational Quality' Assurance Program and Procedure-Manuals.
1.3.4.3 Controlling, processing, tracking, disposition concurrence, and verification of GGNS quality defi-
--ciency documents.
1.3.4.4.
' Analyzing NRC and licensee quality deficiency docu-ments for trends and reporting results to the appropriate' levels of management.
1.3.4.5 Providing for inspections and nondestructive examina-tions.
1.3.4.6 Serving as a primary member of the Plant Safety Review Committee.
1.3.4.7 Reviewing and approving Quality Assurance Instruc-tions, as applicable.
1.3.4.8 Providing for the quality review of procurement docu-ments; Page 4 of 15 Policy 1 Rev. 11 0QAMR11.B/SQPFLR
OPERATIONAL QUALITY ASSURANCE MANUAL.
. TITLE: ORGANIZATION
1.3.4 (Continued)
1.3.4.9 Providing for the performance of receipt inspection activities.
1.3.5 General Manager, Plant Operations The General Manager, Plant Operations reports to the Vice President, Operations GGNS and is delegated the responsibility and authority for assuring the safe, reliable and efficient operation of the plant within the constraints of applicable regulatory-requirements and the operating license.
He super-vises the operating plant staff; approves Plant Administrative Procedures; authorizes implementation of design changes and plant-modifications; implements repairs; reports appropriate matters to management and the Safety Review Committee; and generally administers plant operations on a day-to-day basis.
He has overall responsibility for execution of the Operational Quality Assurance Program at GGNS; except for training activities, licensing activities, implementation of design 11 changes and plant modifications; and has the authority to stop work if an activity at the Plant is not in conformance with program requirements.
He has overall responsibility for developing systems to manage the storage and retrieval of records and for coordinating the turnover of contractor vendor records.
It is the responsibility of the General Manager, Plant Operations, to assure that these functions are performed in accordance with-the requirements of the Operational Quality Assurance Program.
The General Manager, Plant Operations, is assisted in carrying out his-responsibilities by the Manager, Plant Operations; the Manager, Plant Maintenance; the Manager, Materials, Purchasing and Contracts; and, Manager, Performance & System Engineering as well as the operating plant staff which includes individuals knowledgeable in plant radiation protection and plant security.
In addition, the General Manager, Plant Operations-oversees the activities of the Plant Safety Review Committee and provides for necessary liaison with the Safety Review Committee of which he is a member.
1.3.6 This Section-deleted in Revision 4.
1.3.7 Director, Nuclear Safety and Regulatory Affairs The Director, Nuclear Safety and Regulatory Affairs reports to 13 the Vice-President, Operations GGNS and is responsible for directing the activities of the Nuclear Safety and Regulatory Affairs Staff. The Nuclear Safety and Regulatory Affairs Staff is responsible for securing the licenses and permits required to operate-the plant. ---The Nuclear Safety and Regulatory Affairs Staff also provides technical assistance in the areas of safety analysis and fire protection.
This staff provides 0QAMRll.B/SQPFLR
OPERATIONAL QUALITY ASSURANCE MANUAL.
TITLE: ORGANIZATION j
\\
1.3.7 (Continued)
support to the Vice President, Operations GGNS in matters related to Safety Review Committee activities.
It is the responsibility of the Director, Nuclear Safety and Regulatory 11 Affairs to assure that these functions are performed in accordance with the requirements of the Operational Quality Assurance Program.
1.3.8 Director, Design Engineering GGNS The Director, Design Engineering GGNS reports to the Vice President, Engineering, and is responsible for directing the activities of the Nuclear Plant Engineering Staff.
Nuclear
. Plant Engineering, consisting of the Manager, Engineering Support; Principal Engineer, Civil; Principal Engineer, 11 Electrical;. Principal Engineer, Mechanical; and, their respective staffs and the Quality Engineer are responsible for plant design, design review, modifications, chemical /
environmental analysis, special processes, and accident and transient analyses.
It is the responsibility of the Director, Design' Engineering GGNS to assure that these functions are performed in accordance with the requirements of the Opera-tional Quality Assurance Program. The Director, Design Engineering.GGNS is responsible for reviewing GGNS design documents for compliance with the Operational Quality Assurance Program requirements and concurring with the same.
1.3.9 Safety Review Committee (SRC) f Committee composition, responsibility and authority, subjects to be reviewed, administrative controls, and. reporting requirements are addressed in Section 6 of the Technical Specifications and Section.13 of the UFSAR for the applicable nuclear gener_ating station.
1.3.10 Plant Safety Review Committee (PSRC)
Committee composition, responsibility and authority, subjects to be reviewed, and reporting requirements are addressed in Section.6 of the Technical Specifications aM Section 13 of the UFSAR for the applicable nuclear generating station.
1.3.11 This section deleted in Revision 10, 1.3.12 Other Organizations Other organizations, contractors, or consultants may be dele-gated certain functions which fall under the Operational Quality Assurance Program.
In such cases, the licensee shall retain responsibility for the delegated work.
u Page 6 of 15 Policy 1 Rev. 11 0QAMR11.8/SQPFLR L-
OPERATIONAL QUALITY ASSURANCE MANUAL TITLE: ORGANIZATION
1.3 (Continued)
1.3.13 Minimum Qualifications of Quality Personnel The qualification requirements and experience levels of Quality personnel are such as to assure competence commensurate with the responsibilities of the position and are described in ANSI /ANS 3.1 (Draft 12/79).
See Appendix A.
Key Quality per-sonnel include the Director, Quality; the Manager, Quality 11 Services; the Manager, Quality Systems; and the Manager, Quality.
1.3.14 This section deleted in Revision 5 1.3.15 This section deleted in Revision 11 11 1.3.16 Director, Nuclear Support The Director, Nuclear Support reports to the Vice President, Operations Support and is responsible for directing the activities of the Nuclear Support Department.
The Nuclear Support Department provides technical support in the areas of environmental licensing and permitting; health physics; environmental protection; chemistry and waste management.
It is the responsibility of the Director, Nuclear Support to assure that these functions are performed in accordance with the requirements of the Operational Quality Assurance Program.
1.3.17 This section deleted in Revision 5 1.3.18 Manager, Quality Systems The Manager, Quality Systems reports directly to the Director, Quality. He directs Quality Programs' staff in audits and assessment activities to verify the adequacy and implementation 11 of quality assurance programs established and implemented by the licensee and onsite vendors.
The Manager, Quality Systems has the authority to initiate ac-tion to stop unsatisfactory work and control further process-ing, delivery or installation of nonconforming items or contin-uation of nonconforming services pending correction of the non-conforming condition.
The primary duties and responsibilities of the Manager, Quality Systems include:
Page 7 of 15 Policy 1 Rev. 11 00AMR11.8/SQPFLR
OPERATIONAL-QUALITY ASSURANCE MANUAL TITLE: ORGANIZATION 1.3.18_(Continued):
1.3.18.1 Providing_foc the planning, scheduling, coordinating, performing and reporting of audit activities.
1.3.18.2 Providing for the planning, scheduling, coordinating, performing and documenting of assessment activities.
11 1.3.18.3 This-section deleted in Revision 9a.
1.3.18.4 This section deleted in Revision 9a.
1.3.18.5 This section deleted in Revision 9a.
1.3.18.6 ' Reviewing and approving Quality Assurance Instructions, as applicable.
1.3.19
-This section deleted in Revision 6.
1.3.20 This Section deleted in Revision 6A.
1.3.21 Vice President, Engineering The Vice President, Engineering reports directly to the President and Chief Operating Officer and is responsible for the administration of all functions associated with engineering and fuel cycle management including control of design activities associated with nuclear core design of GGNS.
He maintains a continuing involvement in quality assurance matters and assesses the scope, status, implementation and effec-tiveness of-the program through contact with and review of re-ports issued by the Director, Quality.
11 1.3.22 This section deleted in. Revision 9.-
1.3.23' Manager, Emergency Preparedness The Manager,-Emergency Preparedness reports to-the Director, Plant Projects and Support and is responsible for the Emergency Preparedness program and associated activities.
It is the responsibility of the Manager,-Emergency. Preparedness to assure-these functions are performed in accordance with the requirements of the Operational Quality. Assurance Program.
I a.
3 Page 8 of 15 Policy 1 Rev. 11 OQAMR11.B/SQPFLR
OPERATIONAL QUALITY ASSURANCE MANUAL TITLE: ORGANIZATION
1.3 (Continued)
1.3.24 Manager, Nuclear Safety andAssessment The Manager, Nuclear Safety and Assessment reports to the Director, Nuclear Safety and Regulatory Af f airs. He is responsible for directing nuclear safety / thermal performance analyses, reliability reviews and safety evaluations and for making independent recommendations to improve both plant safety 11 and reliability as delineated in the Operational Assessment Review Policy and Nuclear Regulatory requirements.
The Manager, Nuclear Safety and Assessment is responsible for carrying out the activities of the Independent Safety Engineer-ing Group (ISEG) as described in Technical Specification 6.2.3 and in accordance with the Operational Quality Assurance Pro-gram.
1.3.25 Manager, Project Management The Manager, Project Management reports directly to the Director, Plant Projects and Support. He is responsible for managing the implementation of various major special projects and programs as may be periodically assigned.
These projects involve hardware and software implementations and planning functions which involve multiple departments.
He assists the Director, Plant Projects and Support as assigned, in technical and administrative matters associated with the Grand Gulf Nuclear Station.
It is the responsibility of the Manager, Project Management to assure these functions are perfonned in accordance with the requirements of the Operational Quality Assurance Program.
1.3.26 Manager, Plant Modification & Construction The Manager, Plant Modification & Construction reports directly to the Director, Plant Projects and Support.
He is responsible for planning, scheduling, and implementing design changes and plant modifications.
He is also responsible for the implementation of assigned major maintenance.
It is the responsibility of the Manager, Plant Modification &
Cons'.ruction to assure these functions are performed in accordance with the requirements of the Operational Quality Assurance Program.
1.3.27 This section deleted in Revision 11, 77 i
Page 9 of 15 Policy 1 Rev. 11 0QAMR11.8/SQPFLR
OPERATIONAL QUALITY ASSURANCF MANUAL TITLE: ORGANIZATION
1.3 (Continued)
1.3.28 Manager, Engineering Support (GGNS)
The Manager, Engineering Support (at GGNS) reports to the Di-L rector, Design Engineering GGNS and is responsible for managing the activities of the Configuration Management, Procurement Engineering, Drafting / Computer Aided Drafting and Engineering 11 Planning and Control disciplines of the Nuclear Plant Engineering Staff to ensure that adequate support is given to the Civil, Electrical, and Mechanical disciplines for all phases of their engineering activities at Grand Gulf Nuclear Station.
It is the responsibility of the Manager, Engineering Support to assure these functions are pcr+~ med in accordance with the requirements of the Operational Quality Assurance Program.
1.3.29 Vice President, Administrative Services & Regulatory Affairs The Vice President, Administrative Services & Regulatory Af-fairs reports directly to the Chairman & Chief Executive Offi-11 cer and is responsible for the administration of all functions associated with Business Services and Materials, Purchasing and Contracts.
He delegates authority and responsibility for the accomplishment of the above activities through the Director, Business Services and the Director, Materials, Purchasing and Contracts.
It is the responsibility of the Vice President, Administrative Services and Regulatory Affairs, to assure these functions are performed in accordance with the Operational Quality Assurance Program.
1.3.30 Director, Business Services The Director, Business Services reports directly to the Vice President, Administrative Services & Regulatory Affairs and is re;ponsible for control and maintenance of corporate direc-tises, policies and procedures; risk management coordination and administrative services.
He delegates authority and res]onsibility through the Manager, Administrative Services.
It is the responsibility of the Director, Business Services to assure these functions are performed in accordance with the requirements of the Operational Quality Assurance Program.
1.3.31 President and Chief Operating Officer The President and Chief Operating Of ficer reports directly to the Chairman and Chief Fxecutive Officer.
He is responsible for administration of all functions associated with the operating and engineering of GGNS and is assisted by the Vice 11 President, Operations GGNS; the Vice President, Engineering; and the Vice President, Operations Support.
It is the responsibility of the President and Chief Operating Officer to assure requirenents of the Operational Quality Assurance Program are implemented by the organizations under his direction.
Page 10 of 15 Policy 1 Rev. 11 3QAMR11.8/SQPFLR
OPERATIONAL QUAllTY ASSURANCE MANUAL TITLE: ORGANIZATION
1.3 (Continued)
1.3.32 Vice President, Operations Support The Vice President, Operations Support reports directly to the President and Chief Operating Officer, and is responsible for the administration of all support functions associated with radiological, radwaste, chemistry, operations, refueling outage management, environmental services, central licensing services, and maintenance services.
He maintains a continuing 31 involvement in quality assurance matters and assesses the scope, status, implementation and effectiveness of the program through contact with and review of reports issued by the Director, Quality.
It is the responsibility of the Vice President, Operations Support to assure that there functions
~
are performed in accordance with the requirements of the Operational Quality Assurance Program.
1.3.33 Director, Plant Projects and Support The Director, Plant Projects and Support reports to the Vice President, Operations GGNS and is responsible for planning, scheduling and implementing major maintenance; managing implementation of major special projects and programs; and emergency preparedness.
Provides management direction to the Manager, Plant Modification and Construction; the Manager, Emergency Preparedness; and the Manager, Project Management.
It is the responsibility of the Director, Plant Projects and Support to assure that these functions are performed in accordance with the requirements of the Operational Quality Assurance Program.
1.3.34 Senior Vice President, Planning & Assurance The Senior Vice President, Planning & Assurance reports direct-ly to the Chairman and Chief Executive Officer and is respon-sible for directing Supplier Quality Assurance and Services 11 Quality Assurance activities.
He delegates through his staff to assure that these activities are performed in accordance with the Operational Quality Assurance Program.
He maintains a continuing awareness of quality matters through applicable re-ports and management audits of the program.
It is the Senior Vice President, Planning & Assurance's responsibility to assure that the requirements of the Operational Quality Assurance Program are implemented by the organizations under his direction.
Page 11 of 15 Policy 1 Rev. 11 0QAMR11.8/SQPFLR
_ OPERATIONAL QUALITY ASSURANCE MANUAL TITLE: ORGANIZATION
1.3 (Continued)
1.3.35 Manager, Quality The Manager, Quality reports directly to the Senior Vice President, Planning & Assurance and is delegated the authority and responsibility for assuring the performance of supplier evaluations and source verification activities to verify the adequacy of quality assurance programs established and implemented by suppliers including suppliers of nuclear fuel and. associated components. The Manager, Quality, is responsible for development, maintenance, control, and approval of procedures that govern supplier quality assurance and services quality assurance activities.
He assures safety related activities are performed in accordance with the Operational Quality Assurance Program.
The primary duties and responsibilities of the Manager, Quality include:
1.3.35.1 Reviewing and approving Supplier Quality Assurance and Services Quality Assurance Procedures; 1.3.35.2 Maintaining adequate communciations with suppliers, contractors and Entergy Operations' organizations; 1.3.35.3 Planning, scheduling, coordinating, and performing 11 supplier evaluations and source verifications; 1.3.35.4 Developing and carrying out an audit program as described in Policy 18.0 of this manual, to verify conformance with the Operational Quality Assurance Program requirements; 1.3.35.5 Reporting to the Senior Vice President, Planning &
Assurance and the-Chairman & Chief Executive Officer on the status and adequacy of the Operational Quality Assurance Program as applicable to Supplier Quality Assurance activities; 1.3.35.6 Reviewing and approving the non-site specific quality assurance program to verify conformance with the
-0perational Quality Assurance Program; 1.3.35.7 Providing for the performance of pre-award evaluation of suppliers; 1.3.35.8 Providing for the control, processing, tracking, disposition, concurrence, and verification of defi-ciency documents documented in accordance with the Services Quality Assurance Manual and Supplier QA procedures.
l l
Page 12 of 15 Policy 1 Rev. 11 l
0QAMR11.B/SQPFLR p
OPERATIONAL QUALITY ASSURANCE MANUAL TITLE: ORGANIZATION 1.3.35 (Continued):
The Manager, Quality, is independent of undue influences and responsibilities for schedules and costs, and has sufficient authority and organizational freedom to identify quality problems, recommend solutions and verify implementation of solutions.
If acceptable solutions cannot be reached he has the responsibility and authority to escalate these matters to 11 the Chairman & Chief Executive Officer.
He has the authority to initiate action to stop unsatisfactory work and control further processing, delivery, or installation of nonconforming items or continuation of nonconforming services pending correction of the nonconforming condition.
1.3.36 This section deleted in Revision 11.
1.3.37 Director, Maintenance Support The Director, Maintenance Support reports to the Vice Presi-dent, Operations Support and is responsible for directing the activities of the Maintenance Support Department.
The Mainte-g nance Support Department provides technical support in the areas of maintenance, system engineering, operations, and refueling outage management to the Grand Gulf staff.
It is the 11 responsibility of the Director, Maintenance Support to assure that these functions are performed in accordance with the requirements of the Operational Quality Assurance Program.
1.3.38 Director, Central Licensing The Director, Central Licensing reports to the Vice President, Operations Support and is responsible for directing the activi-ties of the Central Licensing Department.
The Central Licens-ing Department provides licensing support in the licensing area to the Grand Gulf Nuclear Safety and Regulatory Affairs staff.
It is the responsibility of the Director, Central Licensing to assure that these functions are performed in accordance with the requirements of the Operational Quality Assurance Program.
1.3.39 Director, Materials Purchasing & Contracts The Director, Materials Purchasing and Contracts reports to the Vice President, Administrative Services and Regulatory Affairs and is responsible for directing the activities of the Materials, Purchasing and Contracts Department.
The Materials, Purchasing and Contracts Department provides technical support 11 to GGNS Manager, Materials, Purchasing and Contracts.
He delegates authority and responsibility through the Manager, Purchasing; the Manager, Contracts; the Manager, Material Control; and the Manager, Inventory, Purchasing & Contracts Analysis.
It is the responsibility of the Director, Materials, Page 13 of 15 Policy 1 Rev. 11 0QAMR11.B/SQPFLR
OPERATIONAL QUALITY ASSURANCE MANUAL TITLE: ORGANIZATION
'1.3.39(Continued):
Purchasing and-Contracts to assure that these functions are
-performed in accordance with the requirements of the Opera-tional Quality Assurance Program, 1.3.40 Manager, Fuel Fabrication The Manager, Fuel fabrication, reports to the Director, Nuclear Engineering Analysis, and is responsible for the procurement of nuclear fuel (fabrication and related services, being the design authority for nuclear fuel and core designs, and the direction of nuclear fuel cycle planning.
1.3.41 Director, Nuclear Engineering Analysis The Director,. Nuclear Engineering Analysis reports to-l' the Vice President, Engineering and is responsible for direct-ing the activities of the Nuclear Engineering Analysis Depart-ment. The_ Nuclear Engineering Analysis Department provides nuclear engineering analysis support in the fuel and core design area to Design Engineering GGNS and Performance and System Engineering.
It is the responsibility of the Director, Nuclear Engineering Analysis Department to assure that these l
functions are performed in accordance with the requirements of the Operational Quality Assurance Program.
g 1.3.42 Principal Engineer, Mechanical The-Principal Er.gineer, Mechanical, is responsible for mechanical process designs / design modifications, HVAC L_
designs / design modifications, piping supports, and materials science.- In addition to classical-design activities, the group 7_
' ~
provides consultation advice in-all areas of mechanical engineering.
It is the responsibility of the Principal Engineer, Mechanical l to assure these functions are performed in accordance with the requirements of the Operational Quality Assurance Program.
l l-1.3.43 Principal Engineer, Electrical The Principal Engineer, Electrical, is responsible for electrical-designs / design modifications, electrical cable and equipment layout, electronic engineering, and instrumentation and control / control logic engineering.
In addition to classic j-design activities, the group provides consultation advice in all areas of electrical and electronic engineering.
It is the E
-responsibility of the Principal Engineer, Electrical, to assure these functions are performed in accordance with the requirements of the Operational Quality Assurance Program.
Page 14 of 15 Policy 1 Rev. 11 OQAMR11.B/SQPFLR
CPERA110NAL QUALITY ASSURANCE MANUAL TITLE: ORGANIZATION
1.3 (Continued)
1.3.44 Principal tigineer, Civil The Principal Engineer, Civil, is responsible for structural engineering as required for ductwork supports, pipe supports, miscellaneous structures, etc.
In addition, the group provides engineering capabilities in the area of environmental monitoring, wastewater engineering, fire protection engineer ing/ design, seismic qualification of electrical equipment, and certain hydraulic engineering activities.
It is the responsi-bility of the Principal Engineer, Civil, to assure these func-tions are performed :n accordance with the requirements of the operational Quality Assurance Program.
1.3.45 Manager 3 Engineering Programs The Manager, Engineering Programs, reports to the Vice President, Engineering, and is responsible for managing the activities of the Engineerina Programs group.
The Engineering Programs group provides engineering support to the GGNS Design Engineering Organization in the technical areas of welding, flaw evaluations, fracture mechanics, metallurgy and finite element analysis.
The Manager, Engineering Programs, maintains 11 an awareness of GGNS programs and generic issues in areas as assigned by the Vice President, Engineering, to identify best practices, facilitate peer group activities, and coordinate the development of standards, procedures, and programs between the Entergy Operations Nuclear facilities.
It is the responsibili-ty of the Manager, Engineering Programs, to assure these func-tions are performed in accordance with the requirements of the Operational Quality Assurance Program.
1.3.46 Manager, Engineering Support (Corporate) 1 The Manager, Engineering Support, in the General Office reports to the Vice President, Engineering, and is responsible for man-aging the activities of the Engineering Support group. The Engineering Support group provides engineering support to the Design Engineering Organization in the technical areas of Configuration Management, Probabilistic Risk Assessment, and Procurement Engineering.
The Manager, Engineering Support maintains an awareness of GGNS programs and generic issues in areas as assigned by the Vice President, Engineering, to iden-tify best practices, f acilitate peer group activities, and co-ordinate the development of standards, procedures, and programs between the Entergy Operations Nuclear facilities. It is the responsibility of the Manager, Engineering Support, (Corporate) to assure these functions are performed in accordance with the requirements of the Operational Quality Assurance Program.
Page 15 of 15 Policy 1 Rev. 11 0QAMRll.8/SQPFLR
P, w a..j.-5.
e.,a
.,a 9i e+
.ya..<s.es=%.-ep
<e-e
-.1.eme e v.e m
.w....as.+ed..-em-u
_~~.*-+=v-p..----'-.--+*-*.--a=-rm--
esem.6.-*
N s, T",
i r'*
1 al I
d-; kD g> 7 (t }
t-
---.-m
.,1.i.
9*
'1 4
a gi o <v d
- 3; a
5 4[-j y } { *g (
y'
" ' =
- g p.*5 g,
te "c, a 2. g
__.5 a.r,
a v-
,u s
a c
,_ a e
s-
.P w.._.,6m....a
.q.y.--
w
..h_
.a*
ede
,3.T-4 T
4 1m+
-~
3s
f,*. "?
y r
TVw, - r,
;Y.' e
- ;* f.
C,1 h
_.--x ?
g g.g 7g mg W.
.7, y
=.
w I
~.
4-
~
p g#
3
-,..,_.3 m
's n, ] *f E. *:1 e i-i@YI-i nK
. g *;re oo m.
$E G:, *,
_ ~. _. -.. _. -.. -. _. - _
s.
a g
-M
-1
.W
,- + _
. -r +
~
- n. c
.~
N Y
af
?.
N
", ~
Ya f..
Y 1 4
.g i
jd y ge#
- z m --7
=gL
. 5 o
5 g @.p
- 1 iE j=y
,- j$,'
a ? *.i.,.
E3EY
{ d, Q
- 5
< s +.
-. y4* c a.
y. _....a y '... '.s-
_m 11-2 ft, ;1 s - :.
< c M,
r.
+ u-w 3
.a
- f. 5.' T'Dw-4'-
.v _ ;
++g 34, 7
-.a..
4
.f.. E l,,
- c. tt
- .=
c 2
- ..g
. g...
m.
a.,.,
Q g m*3 4
---~
u ;* - e
. ykg y
., g
-~*
~g
- 4 " --
R
,y-
'5 r
T, a,,,
)
g a-s
__4
-4
.sp o
e.
A
- 21. M ia 3 3
="
~,
.,W. 7, 4
a i; + rws
.e. -
t g.,, g e
- n. ~-
t -
- g v,,, ~'
. ;+
k
+
x :
c 1 o
- 2 sq
- ; y *1r I
d4 g
- L
'3 2 4 ?.
- 8 u
1 o R t
~""
% 3. L,i,,#,.r..
4 37 r
b
- g
.TQ{U.$ -..
m.. $
- . W :
i 1
i M
3 JB w
- W
.$OM
- C.
I' l M
4 g
i
--- ~
6..#,
245
'541
~f i
g.
g33 g4; 74 g
i a.d i-u*-
i yf
- f-i___.
w_--.
e
==.
3 m
- 9. :-
s j-
,2
-l N-,
..2a L. T.
e
- h., l, C &
m m
a w
- 1 i
wu N MC k 4
4 e2 A e v Q
t.,
j
.7..
3 d
4 w
e<
t 4a r
- e. r
=.
<C
' $ h. A
^ ' ' ' ', f f
y'*-
}
a_
a a
e
- a %..,e a <
u d I.
8g
'[
'I d
Lei
- 4J'i w
i 1+
+
u s
u-.
-..a I'f'95
[a.
.M
/.
7-4"
H G p j +5 r-,
PS P 1: E'W :
. 4oy R;.; s9.y i
+y ". w 2 -.
zu 9,
~,*
. p w. -
i
+ ++ : hw
-.g -g m - s 1 %_y, g
i g-3 5
7, s
h Q --"i 9
g ?
r f. ;i w n.
%*5 J 3. u-2? -_ 46]
A t >. Q) - d i i,1.t f 31!
+ 9 'J.
iOE 3 - tm' n:t
- a2s, 4e :
sw ssj 2 d;
. -... J _, _:
awm" y + s.
w
__.L __.
i
.4,e.a
..=.s-eea*u*=
=*4.a.=g
.,.4--,.
- F hk s
.-. 3 l
+<
- g. g g
b
.p.
4
't i
g
.d.
f.
I.
g
Figure 17.2-2 Deleted ir,.'.2v.
8
OPERATIONAL CIAllTY ASSURANCE MANUAL TITLE:- QUALITY ASSURANCE PROGRAM 2.0 QUALITY ASSURANCE PROGRAM 2.1 PURPOSE This Policy describes the Operational Quality Assurance Program for the Grand Gulf Nuclear Station.
2.2 SCOPE This Policy describes the Operational Quality Assurance Program in terms of the objectives to be accomplished, the requirements to be met, and the implementation and control mechanisms which have been established.
The total program is described throughout this Manual.
2.3 APPLICABILITY The requirements of the Operational Quality Assurance Program apply to all individuals or organizations performing functions during the operational Phase which affect the quality of safety-related structures, systems, components or services.
Operational phase functions to which the program applies include:
designing, purchasing, fabricating, handling, shipping, storing, clean-ing, erecting,-installing, inspecting, testing, auditing, operating, 11 maintaining, repairing, refueling, and modifying (Except major modifications which may be excepted and covered under an NRC accepted construction Quality Assurance Program per 00AM 3.5.18.
See Appendix A).
2.4 POLICIES, DIRECTIVES, G0ALS AND OBJECTIVES L
Licensee quality assurance policies, directives, goals, and objectives are summarized-in the statement that all licensee individuals and organizations who perform quality-related activities have responsibility to assure that the Grand Gulf Nuclear Station is designed, constructed and operated in-a manner which protects public health and safety, and promotes reliable and efficient operation.
The Operational Quality Assurance Program is designed to provide the mechanism for assuring that these policies, goals, and objectives are achieved.
j' 2.5 PROGRAM DESCRIPTION The Operational Quality Assurance Program, as described throughout this Manual, delineate.s the measures that assure activities which affect the quality of safety-related structures, systems, components and services L
are' performed in a controlled manner and are sufficiently documented to provide objective evidence of compliance with established requirements.
The Operational Quality Assurance Program is documented by written policies,_ procedures, and instructions; and shall be carried out throughout the life of the plant in accordance with thece policies, directives, procedures, and instructions.
These documents convey the i
Page 1 of 5 Policy 2 Rev. 11 0QAMRll.B/SQPFLR
OPERAfl0NAL QUAT!".! ASSURANCE MANUAL TITLE: QUALITY ASSURANCE PROGRAM
2.5 (Continued)
licensee quality assurance philosophy and requirements to all levels of management and to all organizations and individuals involved witti program implementation. The applicable Policies of the Operational Quality Assurance Program are mandatory for safety-related activities and functions as described in this Manual.
The Operational Quality Assurance Program applies to all activities, including the use of expendable and consumable materials, affecting the safety-related functions of those structures, systems and components which prevent or mitigate the consequences of postulated accidents that could cause undue risk to the health and saf2ty of the public.
The program is designed to comply with the requirements of Appendix B to 10CFR50, " Quality Assurance Criteria for Nuclear Power Plants and fuel Reprocessing Plants" and with the Regulatory Position in applicable NRC Regulatory Guides and ANSI Standards as listed in Appendix A to this Manual.
A listing of structures / systems / components designated safety-related is included in the UFSAR for the applicable nuciear generating station. A Q-list which contains as a minimum those structures / systems / components designated as safety-related in the UFSAR plus those selected nonsafety-related structures / systems / components to which the Quality Assurance Program applies is issued and maintained current.
Nuclear Plant Engineering is responsible for the development and maintenance of this Q-List in accordance with written procedures which delineate the contents of the Q-List. The procedures will assure that structures / systems / components listed in the UFSAR are contained in the Q-list.
The Q-List will be procedurally controlled. The positions authorized to approve changes to the Q-List are designated in Appendix B of this Manual.
The applicable requirements of the program are also imposed upon contractors, suppliers and consultants.
Development, control, and use of computer programs for design control act:,ities as described in Policy 3 for safety-related structures, systems and components will be conducted in accordance with the Operational Quality Assurance Program.
2.5.1 Operational Quality Assurance Manual The Operational Quality Assurance Manual consists of quality assurance policies, goals, and objectives and has been developed in accordance with applicable regulations, codes, and standards.
It describes the Operational Quality Assurance Program and delineates the responsibilities and requirements imposed by the program for the performance of safety-related activities.
Page 2 of 5 Policy 2 Rev. 11 OQAMRll.B/SQPFLR
OPERATIONAL QUALITY ASSURANCE MANUAL f
TITLE: QUALITY ASSURANCE PROGRAM
2.5.1 (Continued)
The Director, Quality is responsible for maintaining the Manual and controlling its distribution, including revisions thereto, in accordance with approved Quality Assurance Procedures.
Revisions to the Manual will be processed per 10CFR50.54(a),
2.5.2 Implementing Policies, Directives, Procedures and Instructions i
The Operational Quality Assurance Program is implemented through the use of written, approved policies, directives, procedures and instructions generated by the organizations responsible for the performance of the specif1c functions as outlined in Appendix B of this Manual.
The Quality Assurm na Procedure Manual contains the implementing procedures / instructions for the quality functions performed by Quality Programs. Quclity Assurance Procedures / Instructions provide measures to assure that quality-related activities are performed in a controlled manner and are documented to provide objective evidence of compliance with program requirements.
The Director, Quality is responsible for approving Quality Assurance Procedures prior to implementation.
The Manager, Quality Services and the Manager, Qaality Systems are responsible for approving Quality Assurance Instructions prior to imp'lementation.
Quality-related functions performed by other organizations are controlled and documented in accordance with procedures prepared, approved and controlled by the organization performing the function. These procedures assure that the functions are accomplished in a controlled manner, with specified equipment, under suitable environmental conditions, and that prerequisites have been satisfied prior to inspection or testing.
Appendix C to this Manual provides a matrix of Quality Assurance Procedures cross-referenced to the criteria of Appendix B to 10CFR50 which they implement.
2.S.3 Indoctrination and Training Indoctrination and training programs are established for both onsite and offsite personnel performing quality-affecting activities by the organizations responsible for the activities.
These prograns are implemented by appropriate training plans and procedures which assure that:
2.5.3.1 Personnel responsible for performing quality-affecting activities are instructed as to the purpose, scope and implementation of manuals, procedures and instructions; Page 3 of 5 Policy 2 Rev. 11 0Qt.MRll.8/SQPFLR
OPERATIONAL QUALITY ASSURANCE MANUAL TITLE: QUALITY ASSURANCE PROGRAM
2.5.3 (Continued)
2.5.3.2 Personnel performing quality-affecting activities are trained and qualified in the principles and tech-niques of the activity being performed; 2.5.3.3 Proficiency of personnel performing quality-affecting activities is maintained by retraining, reexamining or recertifying; 2.5.3.4 The scope, method and objective of the training are documented; 2.5.3.5 Records of training sessions are prepared and maintained, including identification of the cantent, the attendees and the date the training was conducted.
2.5.4 This section deleted in Revision 5.
2.5.5 Resolution of Disputes _
Disputes arising between licensee organizaticns on any quality assurance matter which cannot be resolved by management of the involved organizations will be referred to the Vice President, Engineering; the Vice President, Operations GGNS; the Senior Vice President, Planning & Assurance; the Vice President, /d-ministrative Services & Regulatory Affairs; the Vice President, legal and External Affairs for resolution.
11 2.5.6 Quality Responsibilities Quality responsibilities for the implementation of major activities addressed in this Manual are designated in the individual policies of this Manual.
2.5.7 This section deleted in Revision 11.
l11 2.5.8 Definitions The terms and phrasr given in the " Definition" portions of the ANSI Standards endorsed by this Program in Appendix A shall apply as well as those given in pertinent sections of the applicable portions of Title 10, Code of Federal Regulations.
As used throughout this Operational Quality Assurance Program and its implementing procedures, the following words shall be construed to have the special cefinitions given:
2.5.8.1 Shall - A requirement considered enforceable by the appropriate regulatory body.
Page 4 of 5 Policy 2 Rev. 11 0QAMRll.B/SQPFLR
OPERATIONAL QUALITY ASSURANCE MANUAL TITLE: QUALITY ASSURANCE PROGRAM 2.5.8.(Continued):
2.5.8.2 Should - A recommendation, but not an enforceable requirement. Management expcts each employee using plant directives to carry out any "should" statement unless circumstances prevent or necessitate a deviation.
2.5.8.3 May - An option, neither a recommendation or a requirement.
2.5.8.4 Must - A requirement normally established by licensee management or may be used to meet regulatory intent.
2.5.8.5 AdditionalitemsaredefinedinAppendixA(seeunder Regulatory Guide 1.74), individual Quality Assurance Procedures and other quality documents.
2.5.8.6 Any words which have not been defined in 1 through 5 above or item 7 below shall be as defined in a contem)orary collegiate dictionary by a well known publisler or. authority.
2.5.8.7 Will - Is defined the same as Shall.
2.5.9 Quality Assurance Position Statements Quality Assurance Position Statements are issued when consid-cred necessary by the Director, Quality, for use in 11 interpretation of certain commitments in the Operational Quali-ty Assurance Manual..These statements are not a part of the NRC accepted Operational Quality Assurance Manual, and are be-ing included in the manual binder only for the convenience of the users.
2.5.10 Resolution of Differences Every attempt has been made to include the pertinent require-ments from external documents, included in this Program by the commitments in Appendix A, within these Policies; no known con-flicts exist between those commitments and these Policies. Dif-ferences arising during future reviews or implementation of the
-Program, must-be brought to the attention of the Director,
' Quality who initiates changes to the commitments or the Policies as necessary to resolve the differences.
The pro-visions delineated in these Policies shall take precedence over differing requirements given elsewhere until the Director, 71 Quality has evaluated the issue and determined which requirement (s) must be modified.
Page 5 of 5 Policy 2 Rev. 11 0QAMR11.8/SQPFLR
.0PERATIONAL QUALITY ASSURANCE MANUAL TITLE:' QUALITY ASSURANCE PROGRAM 3.0' DESIGN CONTROL' 3.1 PURPOSE This Policy describec the Operational Quality Assurance Program measures to control design at' vities affecting safety-related structures, systems and components for the Grand Gulf Nuclear Station.
3.2 -SCOPE This Policy delineates responsibilities and defines requirements for the development and implementation of design control measures to assure that design activities are carried out in a planned, controlled and orderly manner.
3.3 -APPLICABILITY l
The requirements of this Policy apply to all organizations performing design functions on safety-related structures, systems or components during the operational phase of nuclear power plant activities.
3.4 RESPONSIBILITY
- 3. 4.1 -
Responsibility and authority for the control of design activities related to modifications or changes to plant safety-related structures, systems or components (incl" ding control of accident and transient analyses, but excluding nuclear fuel and nuclear core design see 3.4.5) during the operational phase are delegated to the Director, Design Engineering GGNS.
The General Manager, Plant Operations authorizes the design modification or change to be implemented by the Manager, Plant Modification & Construction.
The Director, Design Engineering GGNS is responsible for assuring that procedures are developed and im.nlemented to control the design activities of Nuclear Plant Engineering in accordance with the requirements-of this Policy.
3.4.2 The reviewing of proposed 10CFR50.59 changes is completed as required by the Technical Specifications.
This is described in appropriate procedures. When a proposed change is requested,.
the Director, Design Engineering GGNS initiates the design change (except in cases related to nuclear fuel and core de-L sign) and assures submittal of the safety evaluation per 10CFR50.59,tothePlantSafetyReviewCommittee(PSRC).
The Manager, Fuel Fabrication is responsible for initiating design 11 changes related to nuclear fuel and. core design and for coordinating with Nuclear Safety and Regulatory Affairs and Nuclear Plant Engineering in the development of required 10CFR50.59 evaluation (s) and submittal of the evaluation (s) to the PSRC.
The Manager, Plant Modification & Construction is responsible (except in cases related to nuclear fuel) for the coordination of scheduling and installation of Plant modifica-tions, bettennents and repairs once revieweo by the PSRC as Page 1 of 5 Policy 3 Rev. 11 OQAMRll.B/SQPFLR
OPERATIONAL QUAlllY ASSURANCE MANUAL TITLE: QUALITY AS$URANCE PROGRAM 1
3.4.2 (Continued)
l required by Technical Specifications.
The General Manager, i
l Plant Operations is responsible for the scheduling and installation of nuclear fuel and core related design changes once reviewed by the PSRC as required by Technical i
Specifications. The Secretary of the Safety Review Committee 11 (SRC) assures the review of the safety evaln6 tion by the SRC.
The Director, Nuclear Safety and Regulatory Affairs is re-sponsible for developing a summary of the safety evaluation and I
s submittal of the summary to the NRC, as required by 10CFR50.59.
3.4.3 Organizations,upplying material, equipment or services are responsible for complying with the requirements of this Policy to the extent specified in the applicable procurement documents, and for imaosing nem on their contractors and suppliers, as applica)le.
They are also res)onsible for verifying, through surveillance or audits,11at the 3
requirements are being adequately implemented.
3.4.4 The Manager Quality is delegated the responsibility for I
reviewing nuclear fuel and nuclear core (excluding accident and transient analyses) design documents for compliance with Operational Quality Assurance Program requirements and 4
concurring with same; for monitoring the implementation of design control measures by offsite organizations; and for 1
carrying out an audit program related to the above activities, as described in Policy 18.0 of this Manual, to verify conformance with Operational Quality Assurance Program recuire-ments, including the requirements of this Policy.
Those cesign documents include the type design documents originated, rt:-
viewed and approved by the Manager, fuel fabrication.
3) 3.4.5 Responsibility and authority for control of design activities related to modification of or changes to nuclear fuel or nuclear core design (excluding control of accident and transient analysis activities - See 3.4.1) are delegated to the Manager, fuel fabrication.
The Manager, fuel fabrication is involved inn providingdesigninputs;providinginterfacecon-trol; reviewing all " accept-as-is ' or " repair" dispositions for nuclear fuel or core configuration nonconformances, in addi-33 tion the Manager, fuel fabrication, may perform design j
4 verification of fuel related design activities.
The Manager, i
fuel fabrication is responsible for assuring that procedures are developed and implemented for the-above design activities in accordance with the requirements of this Policy.
i Page 2 of 5 Policy 3 Rev. 11 i
0QAMR11.8/SQPFLR
i
}
OPERATIONAL QUALITY ASSURANCE MANUAL TITLE: QUALITY ASSURANCE PROGRAM l
3.4 (Continued)
3.4.6 Responsibility and authority for control of design activities including accident and transient analyses, but excluding modi-ication of or changes to nuclear fuel or nuclear core design) are delegated to the Director, Design Engineering GGNS. Gener-ally, the Director, Design Engineering GGNS is ;.tvolved in:
providing design inputs, providing interface control; controlling design output; and performing design verification.
The Director, Design Engineering GGNS is responsible for assuring that procedures are developed and implemented for the above design activities in accordance with the requirements of thisPolicyandwillprovideorconcurwithall" accept-as-is" or " repair' dispositions (dfication of or changes to nuclear including accident and transient analyses, but excluding mo fuel or nuclear core design) for nonconformances.
The Director, Design Engineering GGNS is res)onsible for reviewing GGNS design documents for compliance wit 1 the Operational
-Quality-Assurance Program requirements and concurring with the same.
3.4.7 The Director, Quality, and the Manager, Quality have the 11 responsibility for carrying out an audit program as described in Policy.18.0 of this manual, to verify conformance with the requirements of the Operational Quality Assurance Program, including t', requirements of this Policy.
3.5 REQUIREMENTS
- 3. 5.1 -
Organizations having design responsibilities shall develop procedures, consistent with the scope of their responsibilities, to provide measures for the control of their design activities.
3.5.2 Procedures shall be developed to assure that applicable design inputs such as design bases,_ regulatory requirements, codes and standards are identified and documented, and are correctly translated into design _ output documents such as specifications, drawings, procedures and instructions.
3.5.3 Procedures shall provide for the identification and documentation of appropriate quality standards to be specified in the design documents.
Deviations and changes from these quality standards shall be controlled.
3.5.4 Procedures shall include measures fort the control of design analyses such as reactor physics, seismic, stress, thermal, hydraulic, radiation, and accident analyses; compatibility of materials; accessibility for inservice inspection, maintenance, and repair.
3.5.5 Provisions shall be made in the procedures for the selection of suitable materials, parts, equipment, and processes which include the use of valid industry standards and specifications.
0QAMRll B/SQPFLR-
. ~
OPERATIONAL QUAll1Y ASSURANCE MANUAL T11LE: QUAll1Y ASSURANCE PROGRAM 3.5(Continued):
3.5.6 Procedures shall require that designs be reviewed to assure thats design characteristics can be controlled, inspected and tested, w approariate; and, insaection and test criteria are identified.
Suci reviews shall
)e documented.
3.5.7 Materials, parts and equipment which are standard, commercial (off-the-shelf), or which have been previously ap) roved for a different application shall be reviewed for suitasility prior to selection. Such reviews shall be documented.
3.5.8 Procedures shall provide for the control of design interfaces for manag ng the flow of design information between organizat ons. Systematic methods shall be established for communicating needed design information across the interfaces, f
including changes to the design information as the work progresses.
3.5.9 Procedures shall include requirements to verify that the design is adequate and that it meets the specified design inputs.
The extent of the GL.lgn verification required shall be a function of the imaortance to safety of the item, the complexity of the design, t1e degree of standardization, the state-of-the-art and the similarity with previously proven designs, in each case however, standardized or previously proven designs shall be reviewed for applicability prior to use.
3.5.10 Acceptable verification methods shall include, t t not be limited to, design reviews, alternate calculativos, or qualification testing.
If a test program is used to verify the adequacy.of a design, qualification testing of a prototype unit under the most adverse design conditions which are appropriate, shall be used.
3.5.11 Individuals or groups res)onsible for design reviews or other verification activities s1all be identified in the procedures and their authority and responsibility shall be defined and
-controlled. Design verification shall be performed by any i
competent individuals or groups other than those who performed the or!ginal design but who may be-from the same organization.
This verification may be performed by the originator's supervisor provided the supervisor is the only technically l-qualified individual available and the appropriate clarification provisions listed in Appendix-A to this Manual are met.
3.5.12 Design and specification changes, including those originating onsite, shall be subject to the same degree of control as the original design and approved by the original design organization unless another qualified, responsible organization is specifically designated.
0QAMR11.8/SQPFLR
__.____,.a
OPERA 110NAL QlIAL11Y ASSFAANCE MANUAL T11LE: QUAlllY AS$ltRANCE PROGRAM
3.5 (Cont'nued)
3.5.13 Errors and deficiencies in the design process, including computer programs, that could adversely affect safety-related structures, systems or components shall be documented, and enrrective action taken to preclude repetition.
3.5.14 heposed modifications or changes which involve an unreview;d
" rety question or a change to the technical specifications shall be handled in accordance with procedures which address the reluirements of 10CfR50.59.
3.5.15 Design records shall be maintained by the General Manager, Plant Operations in accordance with Policy 17.0 of this Manual.
3.5.16 This Section Deleted in Revision 4.
3.5.17 Plant Procedures are provided to assure that respor.ible plant personnel are made aware of design changes /modific hions which may directly affect the performance of their duties.
3.5.18 During operational shase activities of a unit and while the A-E/ Constructor or lis suppliers are performing design or construction activities for that unit, another unit, or for shared facilities at GGNS, the licensee may choose to purchase similar services (i.e., design or construction) for the operatingunit(s),
if such services are purchased:
3.5.18.1 They shall be procured in accordance with the requirements of Policies 4.0 and 7.0 and ANSI N45.2.13 (as modified and included in Appendix A of the 00AM);
3.5.18.2 They shall be in accordance wic the Quality Assurance program (A-E/ Constructor's or his suppliers') in effect for similar activities on other orthesameunit(s)orforsharedfacilities;and 3.5.18.3 The A-E/ Constructor's Quality Assurance Program shall be reviewed by the licensee's Supplier Quality Assurance to assure that any additional requirements which are considered necessary to assure quality have been included.
0QAMRll.8/SQPFLR
OPERATIONAL QUALITY ASSURANCE MANUAL TITLE:
PROCUREMENT DOCUMENT CONTROL 4.0 PROCUREMENT DOCUMENT CONTROL 4.1 PURPOSE This Policy describes the Operational Quality Assurance Program measures to control procurement documents for safety-related material, equipment and services for the Grand Gulf Nuclear Station.
4.2 SCOPE 1his Policy delineates responsibilities and defines requirements for Procurement document preparation, review, approval and change control in order to assure that purchased safety-related items and services will conform to established, specified requirements.
~
4.3 APPLICABIL11Y The requirements of this Policy apply to all procurement documents for.
safety-related material, equipment and services purchased by or for the licensee during the operational phase of nuclear power plant activities.
4.4 RESPONSIBILITY 4.4.1 All organizations participating in the preparation of procurement documents for safety-related items and services during the operational phase are responsible for developing their own procedures or using generic procedures, in either case procurement document control procedures which address the requirements of this Policyr applicable to their scope of activities, shall be implemented.
4.4.2 The General Manager, Plant Operations is responsible for onsite procurement document control.
He is responsible for assuring procurement activities perfonned by the Plant Staf f are ]rocedurally controlled in accordance with the requirements of 11is Policy. This includes preparation, review, approval and issue of procurement documents.
4.4.3 The Manager, Quality Services is responsible for performing quality reviews of procurement documents, prior to issuance, to verify conformance to the requirements of this Policy.
The Manager, Quality Services is responsible for reviewing procedures for procurement document control to assure that they address the applicable requirements of this Policy.
4.4.4 The Director, Materials, Purchasing and Contracts is delegated the responsibility for assuring that general office procurement activities affecting GGNS are procedurally controlled in accordance with the requirements of this Policy. This includes preparation, review, approval and issuance of procurement documents.
0QAMR11.8/SQPFLR
OPERATIONAL QUAll1Y ASSURANCE MANUAL TITLE:
PROCUREMENT DOCUMENT CONTROL 4.4(Continued):
4.4.5 Organizations supplyin material, equipment or services are responsible for comply ng with the applicable requirements of this Policy, as specif ed in the appropriate procurement documents and for imposing them on their contractors and i
suppliers, as applicable.
They are also responsible for verifying, through source verification activities, that the requirements are being adequately implemented.
4.4.6 The Director, Quality is responsible for assuring implementation of procurement document control measures and for quality review of procurement documents and procedures.
The 11 Director, Quality and the Manager, Quality are also responsible for carrying out an audit program, as described in Policy 18.0 of this Manual, to verify conformance with Operational Quality Assurance Program requirements, including the requirements of this Policy.
4.4.7 This section deleted in Revision-10.
4.4.8 The Director, Design Engineering GGNS is responsible for assuring procurement activities performed by the Nuclear Plant Engineering Staff are procedurally controlled in accordance with the requirements of this Policy.
This includes i
preparation, review, approval, and issue of procurement i
documents.
4.4.9 This section deleted in Revision 11.
g 4.4.10 The Manager, Plant Modification & Construction is responsible for assuring procurement activities to support the implementation of design changes and plant modifications are procedurally controlled in accordance with the requirements of this Policy. This. includes preparation, review, approval and issue of procurement documents.
4.4.11 The Manager, Quality is responsible for assuring procurement activities performed by Supplier Quality Assurance and Services 11 Quality Assurance staff are procedurally controlled in accordance with the requirements of this Policy.
This includes preparation, review, approval, and issue of procurement l
documents.
4.5 REQUIREMENTS 4.5.1 Procedures shall be established by the responsible.
organizations to clearly delineate the sequence of actions to be accomplished to control the preparation, review, approval l
and issuance of procurement documents for safety-related items and services.
l Page 2 of 4 Policy 4 Rev. 11 00AMRll.8/SQPFLR
OPERATIONA: QUAll1Y ASSURANCE MANUAL TITLE:
PROCUREMENT DOCUMEN1 CONTROL
4.5 (Continued)
4.5.2 The procedures shall assure that procurement documents issued at all levels of procurement include provisions for the follow-ing, as applicable:
4.5.2.1 A statement of the scope of work to be performed by the contractor or supplier; 4.5.2.2 Identification of the design basis technical requirements by reference to specific drawings, specifications, codes, regulations, industrial standards or other documentation, including revisions thereto, that describe the items or services to be furnished; 4.5.2.3 Identification of test, inspection and acceptance requirements, and any special instructions and requirements for such activities as design, f abrication, identification, cleanir.g, erecting, packaging, handling, shipping and extended storage; 4.5.2.4 Identification of the quality assurance program requirements which must be complied with by the contractor or supplier; 4.5.2.5 Stipulation that the provisions of 10CFR21 apply; 4.5.2.6 Identification of the documentation, such as drawings, specifications, procedures, fabrication and inspections plans, inspection and test records, personnel and procedure qualifications, and chemical and physical test results to be prepared and maintained by the supplier or contractor and requirements for submittal to the licensee for review and approval; 4.5.2.7 Identification of those records to be retained, controlled and maintained by the supplier or contractor and those to be delivered to licensee prior to use or installation of the procured item; 4.5.2.8 The licensee's right of access to the supplier's facilities and records for source quality verification, inspection and audits, as deemed necessary; 4.5.2.9 Extension of applicable requirements to lower tier subcontractors and suppliers, including the licensee's right of access to facilities and records; Page 3 of 4 Policy 4 Rev. 11 OQAMRll.B/SQPFLR
____.____________________.____________________.____m
OPERATIONAL QUALITY ASSURANCE MANUAL TITLE:
PROCUREMENT DOCUMENT CON 1ROL
4.5.2 (Continued)
4.5.2.10 Subject to the clarification of ANSI N45.2.13, Section8.2,giveninAppendixAofthisgrogram, reporting and approving the " Accept-as is or "Re-pair" dispositions of nonconformances; 4.5.2.11 The licensee's right to hold shipment if procurement document requirements, including those for documentation, have not been fulfilled.
-4.5.3 The procedures shall assure that procurement documents are subjected to technical and quality review by qualified personnel-and are approved by designated individuals prior to issuance. The review and approval shall be documented and available for verification.
4.5.4 Review and concurrence with the adequacy of quality requirements shall include verification that the requirements are correctly stated, inspectable and controllable; that there-are adequate acceptance and rejection criteria; and that the procurement documents have been prepared, reviewed and approved in accordance with the requirements of this Policy.
4.5.5 Changes or revisions to procurement documents shall be subjected to an equivalent review and approval as the original documents, and such review and approval shall be documented.
Exceptions to this include changes in quantity, estimated price, cos' euets, taxes, format or editorial changes that do not affect the quality of the item or service.
4.5.6 Procurement docutents for spare or replacement parts.for safety-related structures or systems shall be subject to controls at least equivalent to those required for purchase of original equipment, or those specified by a properly reviewed and approved revision to the original requirements.
l Page 4 of 4 Policy 4 Rev. 11 0QAMR11~B/SQPFLR
OPERAT10NAL QUAllTY ASSURANCE MANUAL Ti1LE:
INSTRUCTIONS, PROCEDURES AND DRAWINGS i
5.0 INSTRUCTIONS, PROCEDURES ANC DRAWINGS 5.1 PURPOSE 1his Policy describes the Operational Quality Assurance Program measures to assure that all activities affecting the quality or safety of the Grand Gulf Nuclear Station are prescribed and accomplished in accordance with documented instructions, procedures, drawings or other documents appropriate to the circumstances.
5.2 SCOPE This Policy delineates responsibilities and defines requirements for the development and implementation of measures designed to assure that safety-related activities are prescribed and accomplished in accordance with documented instructions, procedures or drawings.
5.3 APPLICABILITY The requirements of this Policy apply to all individuals or organizations performing activities which affect the quality of safety-related items during the operational phase of nuclear power plant activities.
5.4 RESPONSIBILITY 5.4.1 All organizations performing activities during the operational phase which affect the quality of safety-related structures, systems and components are responsible for perf orming these activities in accordance with directives, documented instructions, procedures or drawings.
It is the responsibility of the managers of these organizations to assure the development, review, approval and control of directives, instructions, procedures and drawings necessary to control their safety-related activities in accordance with the requirements of this Manual.
It is the responsibility of the Vice President, Engineering; the Vice President, Operations GGNS, the Vice President, Operations Support; Senior Vice President, Planning &
Assurance; and, the Vice President, Administrative Services and Regulatory Aff airs to ensure that those instructions, policies, procedures and drawings that cross internal organizational lines integrate and function in accordance with the above.
5.4.2 This section deleted in Revision 3.
5.4.3 During the operational phase, the General Manager, Plant Operations is responsible for assuring that adequate inspection plans; test calibration, special process, maintenance, test and repair procedures; drawings, specifications and other safety-related documents and revisions thereto are used.
During the implementation of design changes and plant modifications, the Manager, Plant Modification & Construction is responsible for assuring that inspection plans; modification Page 1 of 3 Policy 5 Rev. 11 00AMR11.B/SQPFLR
OPERA 110NAL QUAllIY ASSURANCE MANUAL IllLE:
INSTRUCTIONS, PROCEDURES AND DRAWINGS
5.4.3 (Continued)
procedures; drawings, specifications and other safety-related documents and appropriate revisions thereto are used,
\\11 The Manager, Quality Services is responsible for performing the quality review of procedures / instructions, and determining that the necessary Quality Assurance requirements are included.
He is responsible for determining the need for inspection requirements in work documents. Documents which contain administrative controls which specify quality assurance requirements will also be reviewed by the Manager, Quality Services.
Lower tier documents (section procedures /
instructions) may be reviewed by individuals (other than the preparer) of the organization preparing the documents if such individuals have been indoctrinated in the Operational Quality Assurance Program. The Director, Quality is responsible for indoctrination and certification of these individuals.
5.4.4 The Director, Quality and the Manager, Quality are responsible g
for reviewing and/or approving instructions, procedures or drawings as indicated in Appendix B of this Manual and for cp 'rying out an audit program, as described in Policy 18.0 of this Manual, to verify conformance with Operational Quality Assurance Program requirements, including the requirements of this Policy.
5.5 REQUIREMENTS 5.5.1 Written instructions, procedures, drawings, or other documents appropriate to the circumstances shall be used to provide measures for complying with the requirements of the Operational Quality Assurance Program.
~
5.5.2 Directions commensurate with the nature of the activity shall be prescribed in instructions, procedures and/or drawings for the performance of activities affecting quality.
The activities shall then be performed in accordance with the instructions, procedures and/or drawings.
5.5.3 Instructions, procedures or drawings shall include quantitative and/or qualitative acceptance criteria for verifying that the activities have been satisfactorily accomplished.
5.5.4 The responsible organizations shall establish procedures which define responsibilities and clearly delineate the sequence of actions to be accomplished in the preparation, review, approval and control of instructions, procedures, or drawings, and changes thereto.
Page 2 of 3 Policy 5 Rev, 11 OQAMRll.B/SQPFLR
OPERATIONAL QUALITY ASSURANCE MANUAL 111LE:
INSTRUCTIONS, PROCEDURES AND DRAWINGS f
5.5(Continued):
I 5.5.5 Safety-related administrative procedures must reference docu I
ments used in their preparation.
5.5.6 When the NRC accepts changes to a policy or an appendix which result in more restrictive requirements, affected implementing l
Procedures must be issued or revised within 120 days.
If 4
procedures cannot be revised or issued within 120 days, the manageroftheaffectedorganization(s)llbeaccomplished.must approve a detailing when the required changes wi If the approved changes are less restrictive, the more restrictive requirements must be complied with until the old procedures are revised or new procedures are issued. When changes to procedures (more restrictive) are required by changes to NRC regulations or by Bulletins or Orders, the required procedures shall be changed within 120 days or as stipulated in the i
licensee's response to the Bulletin or Order or as set forth in the Regulation.
The more restrictive time frame shall be met.
1 i
i i
0QAMRll.8/SQPFLR
,,.,w-....-
OPERATIONAL QUALITY ASSURANCE MANUAL TI1LE: DOCUMENT CONTROL 6.0 DOCUMENT CONTROL 6.1 PURPOSE This Policy describes the Operational Quality Assurance Program measures to control safety-related documents for the Grand Gulf Nuclear Station.
6.2 S_ COPE lhis Policy delineates responsibilities and defines requirements for the review, approval, issuance and control of documents and changes or revisions thereto, which prescribe all activities affecting quality or safety.
6.3 APPilCABillTY The requirements of this Policy apply to all individuals or organizations performing functions which affect safety-related structures, systems or components during the operational phase of nuclear pow 0r plant activities.
6.4 RESPONSIBILITY 6.4.1 Responsibility and authority fur the control of safety-related documents during the operational phase are delegated to the individuals / organizations specified in Appendix B of this Manual. They are responsible foi developing and implementing procedures to control the review, approval and issue of documents in accordance with the requirements of this Policy.
6.4.2 Organizations supplying material, equipment or services are resporsible for complying with the applicable requirements of this Policy as specified in the appropriate procurement documents, and for imposing them on their contractors and suppliers, as ap)1icable. They are also responsible for assuring, througi surveillance or audits, that the requirements are being adequately implemented.
6.4.3 This section deleted in Revision 4.
6.4.4 The Director, Quality and the Manager, Quality, are responsible 11 t
for monitoring document control activities and for carrying out an audit program, as described in Policy 18.0 of this Manual, to verify compliance with Operational Quality Assurance Program requirements, including the requirements of this Policy.
6.5 REQUIREMENTS 6.5.1 Procedures shall be established and implemented by the responsible organizations to provide for the control of documents, including changes thereto, which prescribe all activities affecting quality or safety.
These procedures are identified in Appendix B to this Manual.
00AMRI1.B/SQPfLR
OPERA 110NAL QUALITY ASSURANCE MANUAL TITLE: DOCUMENT CONTROL
6.5 (Continued)
6.5.2 1he procedures shall identify the documents to be controlled.
As a minimum, they shall include:
Design Specifications Design, Manufacturing, Construction and Installation Drawings Procurement Documents Quality Assurance Manuals, Procedures and Instractions Operating Procedures Operating and.Special Orders Maintenance and Modification Procedures Manufacturing, inspection and Test Procedures Equipment and Material Control Procedures Refueling Procedures Updated final Safety Analysis Report Design Change Requests / Packages Design Change Notices Quality Deficiency Documents Q-List l
6.5.3 The procedures shall specify the individuals or organizations responsible.for the preparation, review, approval, issuance and control of the documents, and revisions thereto.
6.5.4 Review of documents for adequacy shall be performed by knowledgeable personnel other than the originator.
Reviewers l
shall have access to pertinent background information and shall have adequate understanding of requirements and intent of the document.
6.5.5 Documents shall be approved for issue by authorized personnel prior to release and shall be distributed in accordance with current,' documented distribution lists.
6.5.6 iiaster lists or their equivalents shall be established and maintained to identify the current status of instructions, procedures, specifications, drawings and procurement documents.
The list, shall be available to responsible personnel to preclude the use of superseded documents.
l Page ? of 4 Policy 6 Rev. 11 00AMRll.8/SQPFLR-
OPERATIONAL QUALITY ASSURANCE MANUAL
-TITLE: DOCUMENT CONTROL 6.5_(Continued):
6.5.7 Documents required to perform a specific activity sh:11 be available at the location where the activity is to be performed
)
prior to commencement of the activity. Cancelled, deactivated 1
or superseded documents shall be controlled to prevent their inadvertent use.
6.5.8 Unless delegated to other appropriately qualified i
organizations, changes to documents shall be reviewed and approved by the same organizations that performed the original review and approval.
6.5.8.1 Changes shall be included in the documents (i.e.,
procedures or instructions) prior to implementation of the change, except in those cases where adequate procedural controls allow implementation of changes prior to revision of the original document.
These changes, if considered permanent, shall be incorporated into the original document in a timely manner as defined by Quality Programs.
6.5.8.2 This section deleted in Revision 11.
6.5.8.3 This section deleted in Revision 11.
6.5.8.4 This section deleted in Revision 11.
6.5.9 This section deleted in Revision 11.
11 6.5.10 Subject to the clarification of ANSI N18.7-1976/ANS 3.2, Section 5.2.15 given in Appendix A of this program, plant 3rocedures (as defined in Technical Specification 6.8.1) shall 3e reviewed by an individual knowledgeable in the area affected upon identification of new or revised source material potentially affecting the intent of procedures or prior to use if the procedure / instruction is not used routinely to determine if changes are necessary or desirable. A biennial audit by the Quality Prtgrams Department will be performed to verify the effectiveness of controls used to maintain procedures current.
A revision of the procedure constitutes a procedure review.
6.5.11 following any-modification to a plant system and prior to initiation of any activity affected by the modification, the applicable procedures shall be reviewed to detennine if changes are required.
6.5.12 A documented review of applicable procedures shall be performed following an accident, an unexpected transient, significant operator error, or equipment malfunction which results in a reportable event to determine if changes are required to prevent recurr.-
Page 3 of 4 Policy 6 Rev. 11 j
OPERAfl0NAL QUAll1Y ASSURANCE MANUAL TITLE: DOCUMENT CONTROL 6.5(Continued):
6.5.13 Review and approval of documents, and changes thereto, shall be documented to the extent necessary to provide evidence of compliance with the requirements of this Policy.
0QAMRll.8/SQPFLR
OPERATIONAL QUAllTY ASSURANCE MANUAL TilLE:
CONTROL OF PURCHASED MATERIAL, EQUIPMENT AND SERVICES 7.0 CONTROL OF PURCHASED HATERIAL, EQUIPMENT AND SERVICES i
7.1 PURPOSE This Policy describes the Operational Quality Assurance Program measures to control the procurement of safety-related material, equipment and services for the Grand Gulf Nuclear Station.
7.2 SCOPE This Policy delineates responsibilities and defines requirements for the control of activities performed during the procurement of safety-related items and services in order to assure that such items and services conform to the procurement documents.
7.3 APPLICABILITY _
The requirements of this Policy apply to all safety-related material, equipment and services procured for the operational phase of nuclear power plant activities, and to all individuals or organizations participating in the procurement of such items or services.
7.4 RESPONSIBILITY 7.4.1 Responsibility and authority for controlling the procurement of safety-related material, equipment and services during the operational phase are delegated to; the Director, Nuclear Su)-
port; the Director, Nuclear Safety and Regulatory Affairs; t1e Director, Quality; the Director, Design Engineerirg GGNS; the General Mana er, Plant Operations (for post modification, startup test ng-and operations); the Director, Materials, Il Purchasing and Contracts; the Manager, Quality; and the Direc-tor,PlantProjects& Support.
It is the responsibility of these individuals to assure that the requirements of this Poli-cy, which are applicable to their scope of activities, are im-plemented in accordance with written approved procedures.
These activities include, as appropriate:
source evaluation and se-lection; evaluation of objective evidence of quality furnished by the supplier; source verification; examination of items upon del ivery.
7.4.2 Organizations supplying safety-relited material, equipment and services are responsible for e mplying with the applicable requirements of this Polig, as stipulated in the procurement documents, and for % posing them upon their contractors and suppliers as applicable.
They are also responsible for verifying, through surveillance or audits, that=the requirements are being adequately implemented.
7.4.3 The Director, Quality is delegated the responsibility for assuring implementation of procurement activities at GGNS.
37 He is responsible-for inspection as necessary to assure compliance with the requirements of this Policy.
_0QAMRll.8/SQPFLR
OPERATIONAL QUALITY ASSURANCE MANUAL TITLE:
CONTROL OF PURCHASED MATERIAL, EQUIPMENT AND SERVICES
7.4 (Continued)
11 7.4.4 The Director, Quality is responsible for assuring the implementation of Operational Quality Assurance Program require-ments relative to procurement activities and an audit program, as described in Policy 18.0 of this Manual, to verify confor-mance with Operational Quality Assurance Program requirements, including the requirements of this Policy.
7.4.5 The Manager, Quality is responsible for assuring the 11 implementation of Operational Quality Assurance Program requirements relative to procurement activities, including:
the cuality evaluation of suppliers and source verification, as cescribed in Policy 18.0 of this manual to verify conformance with the Operational Quality Assurance Program requirements, including the requirements of this Policy.
7.5 REQUIREMENTS 7.5.1 Measures shall be established, implemented and documented by the appropriate organizations, consistent with their scope of responsibilities, to assure that purchased material, equipment and services, whether procured directly or through contractors, confonn to the procurement documents.
These measures shall include provisions, as appropriate, for source evaluation and selection, objective evidence of quality furnished by the supplier, inspection, source verification, and/or examination of items upon delivery.
7.5.2 Procedures shall be established to provide for the selection of suppliers based on one or more of the following:
7.5.2.1 An evaluation of the Supplier's Quality Assurance Program / Manual / Procedures, as appropriate.
7.5.2.2 Review and evaluation of historical quality performance data; l
7.5.2.3 Source qualification programs; 7.5.2.4 Source quality surveys; 7.5.2.5 Through the use of Nuclear Procurement Issues Committee (NUPIC) audits and_other utility audits in-i dicating a program meeting appropriate requirements.
A copy of the qualifying audit report shall be ob-tained and reviewed for adequacy and applicability prior to selection.
7.5.2.6 Through the NRC's " Licensee Contractor and Vendor Inspection Status Report" (white book) for contractors with IE letters confirming Quality Assurance Program implementation; Page 2 of 5 Policy 7 Rey, 13 0QAMRil.8/SQPFLR 4
OPERAll0NAL QUAL 11Y ASSURANCE MANUAL TITLE: CONTROL OF PURCHASED MATERI AL, EQUlPMENT AND SERVICES
7.5.2 (Continued)
7.5.2.7 Through documented inforr ion received from others (architect-engineer, NSS: supplier, other utilities, ASME, etc.) indicating a program meeting appropriate Quality Assurance Program requirements.
The procedures shall specify the organizations responsible for performing technical and quality evaluations, the methods of evaluation and the criteria for supplier acceptance.
7.5.3 Evaluation and selection of the supplier shall be performed in accordance with written procedures by qualified quality assurance and technical personnel prior to or concurrent with award of the procurement document.
Items which have been manufactured or are to be manufactured
-prior to this concurrence with the contractor or su) plier.
Quality Assurance Program will be acceptable, but s1all not be relied upon to fulfill any safety-related function until after the item is shown to meet procurement requirements (including Quality Assurance Program).
7.5.4 Results of supplier evaluations shall be documented and retained on file. Any deficiency identified during a supplier evaluation shall be resolved early enough in the procuremer.t cycle to prevent the deficiency from adversely affecting the quality of the purchased product or service.
7.5.5 Procedures shall be. established to provide for evaluation and verification activities such as source verifications, as necessary, to assure the quality of the item and to verify supplier conformance to procurement document requirements.
7.5.6 Inspection procedures shall specify the characteristics or processes to be witnessed, inspected or verified, and accepted.
The method of verification and the extent of documentation required; and those responsible for implementing the inspection.
Quality procedures shall specify the characteristics or processes witnessed, observed or verified, including the method of verification and-the extent of documentation required.
Audits shall be performed in accordance with 3rocedures which implement the requirements of Policy 18.0 of t1is Manual.
7.5.7 The extent and frequency of evaluation and verification activities shall be a function of the relative importance, com-plexity and quality of the item procured and the su) plier's quality performance.
Source verifications may not se necessary when conformance of an item to procurement requirements can be verified by receipt inspection, review of test reports, or other means.
0QAMRil.8/SQPFLR
OPERATIONAL QUAll1Y ASSURANCE MANUAL TITLE:
CONTROL Of PURCHASED MATERIAL, EQUIPMENT AND SERVICES
7.5 (Continued)
7.5.8 Receipt inspection of supplier-furnished items shall be procedurally controlled to assure:
that the items are properly identified and correspond with the identification on the receiving documentation; that the items and acceptance records are inspected and judged acceptable in accordance with predetermined instructions prior to installation or use; that inspection records or certificates of confontiance are available at GGNS prior to installation or use of the item; and, that items accepted and released are identified as to their in-spection status prior to storage or use.
g Controls in Plant and Quality Assurance Procedures will cover the conditional release process, and will assure that 4.he applicable procedural and administrative aspects of this Policy (7.5.8) and Policies 8.5.8, 14.5.5 and 15.5.5 of the Operational Quality Assurance Program ere fulfilled.
7.5.9 Records required to be furnished by the supplier shall be specified in the procurement documents, as stipulated in Policy 4.0 of this Manual.
These records shall be reviewed and accepted by personnel specifically designated to perform this activity. These personnel will be designated in accordance with applicable procedures. Other licensee organizations may be used when their areas of expertise provide an adequate basis for such a review.
(e.g., Nuclear fuels could review records from nuclear fuel suppliers.)
7.5.10 The records shall include, as a minimum, documentation that identifies the purchased item and the specific procurement requirements (e.g., codes, standards, specifications) met; and documentation which identifies procurement requirements which have not been met.
Subject to the clarification of ANSI N45.2.13, Section 8.2, given in Appendix A of this Manual, such documentation shall include a description of those nonconformances dispositioned " accept-as-is" or " repair".
7.5.11 Where supplier certificates of conformance are used to identify the requirements met by the item, the certificates of confor-mance shall be periodically evaluated by audits, independent inspections or tests to assure that they are valid.
7.5.12 Spare or replacement parts for safety-related systems or components shall be procured, fabricated and controlled in at-cordance with present Quality Assurance programmatic controls and technical requirements at least equivalent to those used for the original item, or those specified by a properly reviewed and approved revision to the original requirements.
0QAMR11.B/SQPFLR
_._-.._.m._..._.
OPERATIONAL QUALITY ASSURANCE MANUAL TITLE: CONTROL Of PURCHASED MATERIAL, EQUIPMENT AND SERVICES
7.5 (Continued)
I 7.5.13 When a supplier is removed from the Qualified Supaliers List, procedures shall assure that any outstanding purciase orders for i
that sup) lier are reviewed, and appropriate action taken to assure tlat materials subsequently received from that supplier are handled and dispositioned as nonconfonnances.
7.5.14 This section deleted in Revision 6.
i
+
1 0QAMRll.8/SQPFLR
OPERATIONAL QUAllTY ASSURANCE MANUAL 11TLE:
IDEN11FICAT10N AND CON 1ROL Of MATERIALS, PARIS AND COMPONENTS 8.0 1 DEN 11FICAT10N AND CONTROL OF MA1ERIALS, PARIS AND COMPONENTS 8.1 PURPOSE This Policy describes the Operational Quality Assurance Program measures to provide for the identification and control of safety-related material, parts and components for the Grand Gulf Nuclear Station.
8.2 SCOPE This Policy delineates responsibilities end defines requirements for the identification and control of safety-related items in order to assure that only correct and accepted items are used or installed.
8.3 APPLICABIL11Y The requirements of this Policy apply to all individuals or organizations participating in the procurement, fabrication, receipt, storage, installation, operation, modification or repair of safety related items during the operational phase of nuclear power plant activities.
8.4 RESPONSIBILITY 8.4.1 Responsibility and authority for the idcntification, control and testing of materials, parts and components during the operational phase are delegated to the General Manager, Plant Operations except, during implementation of design changes and plant modifications, the Manager, Plant Modification & Construction is responsible for this activity.
They are responsible for assuring that procedures are established to address the applicable requirements of this Policy, and that identification and control of safety-related items is maintained in accordance with the procedures from procurement of the item through fabrication, storage, installation and use.
8.4.2 Organizations supplying safety-related material, equipment and services are responsible for complying with the applicable requirements of this Policy, as stipulated in the proc rement documents, and for imposing them on their contractors and suppliers as applicable.
They are also responsible for verifying, through surveillance or audits, that the requirements are being adequately implemented.
8.4.3 The Mcuager, Quality Services is delegated the responsibility for assuring implementation of identification and control re-quirements for items at GGNS by receipt inspection and other l 3) inspections.
The Manager, Quality Services is responsible for reviewing procedures and work documents to the extent necessary to verify conformance to the applicable requirements of this Policy.
e 0QAMRll.B/50PFLR
OPERATIONAL QUALITY ASSURANCE MANUAL Ti1LE:
10ENTiflCAT10N AND CONTROL Of MATERIALS, paris AND COMPONENTS
8.4 (Continued)
8.4.4 The Director. Quality and the Manager, Quality have the il responsibility for carrying out an audit program, as described j
in Policy 18.0 of this Manual, to verify conformance with the requirements of the Operational Quality Assurance Program, including the requirements of this Policy.
8.5 REQUIREMENTS 8.5.1 Procedures shall be estabilshed and implemented to provide for the identification and control of safety-related materials, parts and components, including partially fabricated subassemblies, in order to assure that only correct and accepted items are used and installed.
8.5.2 The procedures shall be developed by the appropriate organizations to cover the various stages from procurement of the item through fabrication, receipt, storage, installation, use, modification or repair.
8.5.3 The procedures shall provide assurance that a unique identification of items is maintained, such as by part number, serial number, heat number, drawing identification number or other appropriate means.
8.5.4 The procedures shall assure that identification is maintained either on the item or on records traceable to the item.
Physical identification, such as by marking or tagging, shall be used to the maximum extent practical.
8.5.5 When specified by codes, standards, arocurement documents, or other requirements; identification s1all be such that items are traceable to a)propriate documentation (e.g., specifications, drawings, purclase orders, manufacturing and ins)ection documents, nonconformance reports, physical or clemical mill test reports).
i 8.5.6 Where identification marking is employed, the marking shall be clear, unambiguous and indelible, and shall be applied in such a manner as not to affect the fit, function or quality of the item.
8.5.7 Markings shall be transferred to each part of an item, if subdivided, and shall not be obliterated or hidden by surface treatment or coatings unless other means of identification are substituted.
l Page 2 of 3 Policy 8 Rev. 11 0QAMR11.8/SQPFLR
OPERA 110NAL QUALITY ASSURANCE MANUAL T11LE:
IDENilf! CATION AND CONTROL OF MATERIALS, PARTS AND COMPONENTS
8.5 (Continued)
8.5.8 Procedures shall provide for the verification and documentation of correct iden'.ification of items prior to release for fabrication, assembling, shipping, storage or installation.
Items may be conditionally released under adequate procedural controls.
These controls shall assure that the system, subsystem, or component that rc::eives such items is considered inoperable, no reliance-shall be placed on such system, subsystem, or component for fulfilling their intended safety function.
The Manager, Quality Services is responsible for reviewing and concurring with conditional releases.
Applicable procedural and administrative aspects of this Policy (8.5.8) and Policies 7.5.8. 14.5.5 and 15.5.5 of the Operational' Quality Assurance Program shall be fulfilled.
j b
0QAMRll.8/SQPFLR m,
OPERATIONAL QUAllTY ASSURANCE MANUAL TITLE: CONTROL Of SPECIAL PROCESSES 9.0 CONTROL OF SPECIAL PROCESSES 9.1 PURPOSE This Policy describes the Operational Quality Assurance Program measures to provide for the control of safety-related special processes for the Grand Gulf Nuclear Station.
9.2 SCOPE This Policy delineates responsibilities and defines recuirements for the control of special processes including, but not limitec to, cleaning, heat treating, welding, nondestructive examination or unique fabricating or testing processes which require interim in-process controls.
9.3 APPLICABILITY The requirements of this Policy apply to all individuals or organizations performing special processes during the operational phase of nuclear power plant activities under this Operational Quality Assurance Program.
9.4 RESPONSIBILITY 9.4.1 Responsibility and authority for the control of special
. processes, except nondestructive examination, at GGNS during 11 the operational phase are delegated to the General Manager, Plant Operations. During the implementation of design changes and plant modifications, the Manager, Plant Modification
& Construction is responsible for ensuring that special arocesses are controlled in accordance with procedures developed by the General Manager, Plant Operatbns.
Responsibility and authority.for the control of nondestructive examination are
~
deligated to the Director, Quality.
They are responsible for l11 assuring that special processes are performed in accordance with procedures and instructions which imalement the requirements of this Policy.
They are also'responsiale for assuring that.
contractors who are delegated responsibilities for the onsite performance of special processes, impose the applicable requirements of this Policy on their internal operations and on their contractors and suppliers.
9.4.2 Offsite organizations responsibic for the performance of special processes-shall be subject to the applicable requirements of this Policy as specified in the appropriate procurement documents.
Individuals or organizations responsible for the preaaration of procurement documents shall assure that the applica)le requirements of this Policy are included, as stipulated in Policy 4.0 of this Manual.
0QAMR11.B/SQPFLR
__.m OPERA 110NAL QUALITY ASSURANCE MANUAL TITLE:
CON 1ROL OF SPECIAL PROCESSES l
9.4(Continued):
9.4.3 The Manager, Quality Services is responsible for reviewing Plant Administrative Procedures and Nuclear Plant Engineering Procedures, controlling special processes, and for reviewing work documents and inspection of special process activities, including nondestructive examinations, to the extent necessary to verify conformance to the requirements of this Policy.
i 9.4.4 The Director, Quality and the Manager, Quality have the 11 responsibility for monitoring the special process control measures of offsite organizations, and for carrying out an audit program, as described in Policy 18.0 of this Manual; to verify conformance with the requirements of the Operational Quality Assurance Program, including the requirements of this Policy.
9.4.5 The Director, Design Engineering CGNS has the responsibility l
for assuring that special process standards and specifications are established to address the applicable requirements of this Policy.
lie is also responsible for reviewing and approving all 37 contractor special process standards prior to use at GGNS 9.5 REQUIREMENTS 9.5.1 Procedures shall be developed and-implemented by the responsible organizations to assure the control nf special processes including, but not limited to, chemical cleaning, heat treating, welding and nondestructive examination.
9.5.2 Special nrocesses shall be accomplished under controlled conditions in accordance with applicable codes, standards, i
specifications or other special requirements.
9.5.3 Special processes shall be performed by personnel qualified in accordance with applicable codes, standards, specifications, or other special requirements.
9.5.4 Equipment and procedures used in ti ? performance of special processes shall be qualified in accordance with applicable codes, standards, specifications or other special requirements.
9.5.5 Qualification records of personnel, equipment and crocedures associated with special processes shall be establL.hed, maintained and kept current.
9.5.6 For special processes not covered by existing codes or standards, or where item quality requirements exceed the requirements of existing codes or standards, the necessary cualifications of personnel, procedures and equipment shall be c efined and documented.
0QAMR11.8/SQPFLR
-~
.-. -.-..= -. - --.-.
OPERATIONAL QUAllTY ASSURANCE MANUAL TITLE:
INSPECTION
-10.0 INSPECTION 10.1 PURPOSE This Policy describes the Operational Quality Assurance Program measures to provide for the inspection of activities affecting the safety of the Grand Gulf Nuclear Station.
10.2 SCOPE This Policy delineates responsibilities and defines requirements for the development and implementation of a program for the inspection of activities affecting safety in order to verify conformance to the documented instructions, procedures and drawings for accomplishing the activity.
10.3 APPLICABillTY The requirements of this Policy apply to all inspections performed on safety-related structures, systems or components during the operational phase of nuclear power plant activities.
10.4 RESPONSIBillTY 10.4.1 Overall responsibility and authority for establishing and implementing an inspection program at GGNS during the operational phase are delegated to the Director, Quality and the Genera! Manager, Plant Operations.
During the implementation of design changes and plant modifications, the Manager, Plant Modification & Construction, in conjunction with the Director, Quality is responsible for 11 these activities.
The Director, Quality is responsible for assuring that procedures / instructions developed for the performance of work operations include appropriate inspection requirements and for assuring that inspections and examinations are performed and documented where necessary to assure quality. The General Manager, Plant Operations and the Manager, Plant Modification &
Construction (forimplementationofdesignchangesand plant modifications) are responsible for assuring that measurements and tests of materials, products or activities are performed and documented for each work operation where necessary to assure quality.
10.4.2 The Manager, Quality Services is delegated the responsibility.for assuring that the onsite inspection program (including receipt inspection) is carried out in accordance with the requirements of this Policy.
The Manager, Quality Services is responsible for reviewing Plant Administrative Procedures which control work instructions, modification and repair instructions; OQAMRll.8/SQPFLR 4
_~._.. _ _ _ _. _. _ _ _ _. _ _ _ _. _. _ _ _ - _ _ _. _ _ _ _
OPERATIONAL QUAllTY ASSURANCE MANUAL TITLE:
INSPECTION
-10.4.2 (Continued):
and other documents to assure that they contain the appropriate inspection requirements.
The Manager Quality Services is responsible for developing procedures for the performance of all quality inspections.
The Manager, Quality Services is responsible for implementing inspection procedures.
The coordination of activities concerning the training and certification of all quality inspectors shall be accomplished by the Director, Quality Level Ill in-spectors are appointed.
All safety-related work authoriza-tions will be reviewed, as defined by the appropriate im-11 plementing Administrative Procedures, by the Manager, Qual-ity Services for detennination of any quality inspection requirements.
Procedures or work authorizing documents which control repetitive tasks are reviewed initially and when revised for inclusion of inspection requirements.
The Manager, Quality is delegated the responsibility for assuring that the source inspection program is carried out in accordance with the requirements of this policy.
10.4.3 The licensee may delegate the responsibility for im)lementing certain portions of the inspection program to otler organizations. However, the licensee retains the ultimate responsibility for assuring that all aspects of the inspection program are carried out. At GGNS, the l11 Manager, Quality Services is responsible for assuring that inspection activities assigned to outside organizations are accomplished in accordance with the requirements of this Policy.
10.4.4 Organizations supplying safety-related material, equipment and services are responsible for complying with the applicable requirements of this Policy, as stipulated in the procurement documents, and for imposing them upon their contractors and suppliers as applicable.
They are also responsible for verifying, through surveillance or I
audits,.that the requirements are being adequately implemented.
10.4.5 The Director, Quality is responsible for qualificatio of inspectors.
The Director. Quality and the Manager, 11 l
Quality have the responsibility for carrying out an audit program, as described in Policy 18.0 of this Manual, to verify conformance with.the requirements of the Operational Quality Assurance Program, including'the requirements of this Policy.
i 9
1 Page 2 of 5-Policy 10 Rev. 11
..00AMRll.8/SQPfLR
OPERATIONAL QUAllTY ASSURANCE MANUAL llTLE:
INSPECTION 10.5 Rf_QUIREMENTS 10.5.1 Inspection requirements shall be included in applicable specifications, drawings, procedures, instructions or other documents which prescribe and control safety-related activities.
10.5.2 These inspection requirements shall be translated into a documented inspection program, to be implemented by the respt,asible organizations in accordance with written Procedures, which verifies that the activities are accomplished in accordance with the specifications, drawings, procedures or instructions.
10.5.3 Inspection procedures, instructions or checklists shall include provisions, as required, for the following:
10.5.3.1 Identification of characteristics and activities to be inspected; 10.5.3.2 IJentification of the individuals or organizations responsible for performing the inspection activities; 10.5.3.3 Identification of acceptance and rejection criteria; 10.5.3.4 A description of the method of inspection; 10.5.3.5 Recording evidence of th'.ompletion and verification of a manufccturing, inspection or test operation; 10.5.3.6 Recording the identity of the inspector or data recorder and the results of the inspection operation; and, 10.5.3.7 Specifying the necessary measuring and test equipment, including the accuracy requirements.
Accuracy may be specified by requiring a specific model or type of instrument.
10.5.4 The app!icable drawings and specifications shall be available for use with the inspection procedures, instructions or checklists when an inspection operation is being carried out.
10.5.5 Inspections shall be performed by qualified personnel who are independent of those individuals who performed the activity being inspected, inspection of operating activities (work functions associated with normal operation of the P! ant, routine maintenance, and certain technical services routinely assigned to the onsite operat-ing organization) may be conducted by second-line 0QAMR11.B/SQPFLR
OPERATIONAL QUALITY 1 ASSURANCE MANUAL l
TITLE:
INSPECTION 10.5.5 (Continued):
supervisory personnel or by other qualified personnel not assigned first-line supervisory responsibility for conduct of the work.
When inspections of operating activities are performed by individuals other than those who performed or directly supervised the work, but are within the same group, the following controls shall be met:
10.5.5.1 The quality of the work can be demonstrated through a functional test when the activity involves breaching of pressure retaining items; 10.5.5.2 The qualification criteria for inspection personnel are reviewed and found acceptable by Quality Programs p ior to initiating the inspection.
10.5.6 Personnel performing inspections which require specialized qualifications or skills shall be qualified in accordance with applicable codes, standards or licensing requirements, and their qualifications and certif W tions shall be documented and kept current.
10.5.7.
If mandatory inspection hold points are required, the specific hold points shall be specified in the appropriate drawings, specifications, procedures or instructions.
The inspection program shall provide assurance that work does not progress beyond the hold point until released by the designated authority, and that required notification and acknowledgement has been satisfied prior to work continuing.
10.5.8 If insrn tion is imporsible or disadvantageous, indirect control shall be provided by monitoring processing methods, equipment, and personnel.
Inspection and process monitoring shall be utilized if control _is inadequate without both.
10.5.9 Instructions addressing maintenance, modifications, l
_ repairs or replacements shall be reviewed by qualified personnel (other than the preparer) who have the knowledge required to determine the need for inspection, identification of inspection personnel, and documenting
' inspection-results.
L Modifications, repairs and replacements shall be inspected l
10.5.10
-in accordance with the original design and inspection j
requirements or documented engineering approved alternatives.
Page 4 of 5 Policy 10 Rev. 11
_OQAMR11.8/SQPFLR
OPERATIONAL QUALITY ASSURANCE MANUAL TITLE 1NSPECT10N 10.5 (Continued):
10.5.11 Inspection data and results shall be evaluated by designated Personnel to assure that the inspection objectives have been met and that items requiring action or follow up are identified and documented.
10.5.12 Records shall be kept in sufficient detail to provide adequate confirmation of the inspection program.
Records shall be maintained in accordance with Policy 17.0 of this Manual.
10.5.13 Inspections need not be performed for each specific work activity.
Procedures used for assigning inspections shall require the following to be evaluated in assignment of inspections.
10.5.13.1 Complexity, magnitude or criticality of the wort.
10.5.13.2 Documented engineering inspection requirements.
10.5.13.3 Design organization inspection requirements.
10.5.13.4 Components safety impact.
10.5.14 Inspections shall be performed on repetitive, routine and rework items as determined by the Manager, Quality
- Services, r
Page 5 of 5 Policy 10 Rev. 11 0QAMR11.8/SQPFLR
OPERATIONAL QUALITY ASS'URANCE MANUAL TITLE:
TEST' CONTROL' 11.0 TEST CONTROL 11.1 PURPOSE This Policy describes the Operational Quality Assurance Program measures to control testing of safety-related structures, systems and components for the Grand Gulf Nuclear Station.
11.2 SCOPE This Policy delineates responsibilities and defines requirements for the establishment and implementation of a test program to assure that testing required to demonstrate that safety-related items will perform satisfactorily in service is identified, accomplished and documented.
t.1 APPLICABillTY 7
The requirements of this Policy apply to all testing performed on safety-related structures, systems and components during the operational phase of nuclear power plant activities and also to required preoperational testing.
11.4 RESPONSIBILITY 11.4.1 The responsibility and authority for the development and implementation of maintenance and surveillance testing programs during the operational phase are delegated to the General Manager, Plant Operations.
The General Manager, Plant Operations is also responsible for the development and implementation of testing programs for-design changes and plant modifications.- He is responsible for assuring that the test programs are established and implemented in 11 ac_cordance with procedures and instructions which address the requirements of this Policy.
He is also responsible for assuring that contractors who are delegated onsite testing responsibilities impose tne applicable requirements of this Policy on their internal operations and on their contractors or suppliers.
11.4.2 Organizations responsible for conducting offsite testing are subject to the applicable requirements of this Policy as specified:in the appropriate procurement documents.
Individuals or organizations responsible for the preparation'of procurement documents shall assure that the-
-applicable requirements of this Policy are included, as stipulated in Policy 4.0 of this Manual.
11.4.3' This section deleted in Revision 3.
-0QAMR11.8/SQPFLR
OPERATIONAL QOALITY ASSURANCE MANUAL.
TITLE:- TEST CONTROL-
_.11.4(Continued):
11.4.4 The Manager, Quality Services is delegated-the
- responsibility for assuring implementation of test activities at GGNS by inspection.
He is responsible for reviewing test programs and Plant Administrative 31 Procedures which control testing to verify conformance to the requirements of this Policy.
11.4.5 The Director, Quality and the Manager, Quality have the responsibility for carrying out an audit program, as described in Policy 18.0 of this Manual, to verify conformance with the requirements of the Operational Quality Assurance Program, including the iequirements of this Policy.
.11.5 RE00lREMEN15 11.5.1 A test program shall be established and implemented to assure that testing required to demonstrate that a safety-related structure, system or componer.t will perform satisfactorily in service is identified and documented, and_that the testing is performed in c.ccordance with written, controlled test procedures.
11.5.2 The test program shall be implemented by the responsible organizations to cover all required testing, including
_ prototype _ tests, preoperational tests, initial start-up tests,-surveillance tests, and_ tests associated with plant maintenance and modifications during the operational phase.
11.5.3 This section deleted in Revision 3.
11.5.4 This~section deleted in Revision 3.
11.5.5 Surveillance testing during the operational phase shall be performed to provide assurance that failures or substandard performance do not remain undetected and that the required reliability of safety-related systems is maintained. A surveillance testing schedule (s) shall be established reflecting the status of all planned in-plant surveillance tests and inspections.
Frequency of sarveillance tests may be related to the results of reliability analyses, the frequency and type of service, or age of the item, as appropriate.
~11.5.6 Tests performed following plant modifications, repairs or replacements shall be conducted in accordance with the original design and testing requirements or engineering approved, documented alternatives.
Testing shall be suf ficient to confirm that the modifications or changes reasonably produce expected results and that the change does not reduce safety of operations.
0QAMR11.B/SQPFLR
OPERATIONAL QUALITY ASSURANCE MANUAL l
TITLE: TEST CONTROL 11.5 (Continued) 11.5.7 Written procedures for performing the tests shall incorporate or reference the following, as applicable:
11.5.7.1 A description of test objectives; 11.5.7.2 The requirements and acceptance limits contained in applicable design and procurement documents; 11.5.7.3 Instructions for performing the test; 11.5.7.4 Test prerequisites (e.g., calibrated instrumentation; adequate and appropriate equipment; trained, qualified, and licensed or
~
certified personnel; assurance of completeness of the item to be tested; suitable and controlled environmental conditions; and provisions for data collection and storage);
11.5.7.5 Hold points or witness points for inspection by designated personnel; 11.5.7.6 Acceptance and rejection criteria; 11.5.7.7 Methods of documenting or recording test data and results.
11.5.8 The documented test results shall be evaluated and their acceptability determined by qualified individuals or organizations as designated in the procedures.
0QAMR11.8/SQPFLR
OPERATIONAL QUALITY ASSURANCE MANUAL TI1LE: CONTROL OF MEASURING AND TEST EQUIPMENT 12.0 CONTROL OF MEASURING __AND TEST EQUlPMENT 12.1 PURPOSE This Policy describes the Operational Quality Assurance Program measures to provide for the control of measuring and test equipment used in the performance of safety-related activities for the Grand Gulf Nuclear Station.
12.2 SCOPE This Policy delineates responsibilities and defines requirements for the calibration, maintenance and contrcl of measuring and test equipment used in safety-related applications in order to assure the required accuracy of such equipment.
12.3 APPLICABILITY The requirements of this Policy apply to all tools, instruments, testing equipment and measuring and control devices used in inspections, measurements, tests or monitoring of safety-related components, systems or structures auring the operational phase of nuclear power plant activities.
The requirements of this Policy do not apply to rulers, tape measurers, levels and other such devices if normal commercial practices provide sufficient accuracy.
12.4 RESPONSIBILITY 12.4.1 Responsibility and authority for the control of measuring and test equipment at GGNS during the operational phase l11 are delegated to the General Manager, Plant Operations.
During implementation of design changes and plant modifications, the Manager, Plant Modification &
Construction is responsible for ensuring that all M&TE utilized are controlled in accordance with procedures developed by the General Manager, Plant Operations. They are responsible for assuring that 3rocedures are developed to implement the requirements of tais Policy.
12.4.2 Organizations supplying materials, equipment or services are responsible for complying with the applicable requirements of this Policy, as specified in the appropriate procurement documents and for imposing them on their contractors and suppliers, as applicable.
They are also responsible for verifying, through surveillance or audits, that the requirements are being adequately implemented.
Page 1 of 3 Policy 12 Rev. 11 0QAMRll.B/SQPFLR
OPERATIONAL QUAllTY ASSURANCE MANUAL TITLE: CONTROL 0F MEASURING AND TEST EQUIPMENT i
12.4 (Continued):
12.4.3 The Manager, Quality Systems is delegated the responsibility for assuring by audit the control of measur-ing and test equipment at GGNS.
The Manager, Quality 33 Services is delegated the responsibility for assuring by inspection the control of measuring and test equipment at GGNS.
The Manager, Quality Services is responsible for l11 reviewing Plant Administrative Procedures which govern equipment control instructions to verify conformance to the requirements of this Policy.
12.4.4 The Director, Quality and the Manager, Quality have the 11 responsibility for carrying out an audit program, as described in Policy 18.0 of this Manual, to verify conformance with the requirements of the Operational Quality Assurance Program, including the requirements of this Policy.
12.5 REQUIREMENTS 12.5.1 Organizations performing safety-related functions which require the use of measuring and test equipment such as instruments, control devices, gages, tools, fixtures, calibration standards and nondestructive test equipment shall establish and implement procedures to control the calibration, maintenance and use of such equipment.
12.5.2 Procedures shall assure that measuring and test equipment used for measurements, tests or calibrations is of the proper range and type and is controlled, calibreted, adjusted and maintained at specific intervals, or prior to use, to assure necessary accuracy.
12.5.3 The method and interval of calibration shall be established for each device or generic grouping thereof, and shall be based on the type of equipment, stability and reliability characteristics, required accuracies and other conditions affecting calibration.
12.5.4 Procedures shall provide methods for the positive identification of all measuring and test equipment included under the calibration system, documentation of its calibration status; and traceability to documented Cdlibration test data.
12.5.5 Installed operations measuring and test m uipment requiring calibration shall be labeled, tagged or otherwise controlled in accordance with written, approved procedures to assure that approved calibration intervals are not exceeded. Portable measuring and test equipment may be similarly controlled; but shall, as a minimum, be clearly labeled to indicate the date on which the current calibration expires. Portable measuring and test equipment Page 2 of 3 Policy 12 Rev. 11 00AMRll B/SQPFLR
OPERATIONAL QUALITY ASSURANCE MANUAL TITLE:
CONTROL OF MEASURING AND TEST EQUIPMENT 12.5.5 (Continued):
that has exceeded the approved calibration interval shall not be used for measurements or tests.
12.5.6 Calibration standards shall be traceable to nationally recognized standards; or, where national standards do not exist, provisions shall be established to document the ba-sis for calibration.
In order to establish this traceabil-ity, calibrating standards should have a greater accuracy than the standard being calibrated and possess sufficient range and stability to assure that the standard being cali-brated is within the required tolerance. Calibrating standards with the same accuracy as the standard being calibrated shall be allowed if it can be shown to be adecuate for the requirements and the basis of acceptance is cocumented and evaluated by a technically knowledgeable individual and authorized by responsible management.
12.5.7 Measuring and Test Equipment (M&TE) should be calibrated against standards (for the purpose of calibration M&TE is
. defined as that equipment, whether permanently installed or portable, used to calibrate pennanent plant devices) that have an accuracy of at least four times the required accuracy of the M&TE being calibrated. A standard of lesser accuracy shall be allowed provided that the basis of acceptance is documented, evaluated for adequacy by a technically knowledgeable individual and authorized by responsible management.
Calibration of permanent plant devices shall be against M&TE having sufficient accuracy, greater than the device being calibrated, to assure that the system containing the device is within the specified system tolerance.
The basis for determining the greater than accuracy of the M&TE used shall be reproducible, either by engineering demonstration or documentation. ~ When an accuracy is specified in the Technical Specifications or bases thereof, this accuracy may be used in lieu of one determined by engineering demonstration or documentation.
12.5.8 Measures shall be established to assure that, if a piece of measuring and test equipment is found to be out of calibration, an evaluation shall be made and documented, in accordance with Policy 15.0, to verify the validity of previous tests and the acceptability of devices tested since the time of the.last calibration. A permanent plant device which is found out of calibration, but within the tolerance given in the Technical Specifications, may be adj us ted.
Such actions shall be documented, but they need not be evaluated or processed as specified in Policy 15.0.
12.5.9 If any calibration, testing or measuring device is consistently found to be out of calibration, it shall be repaired or replaced.
Page 3 of 3 Policy 12 Rev. 11 OQAMRI).B/SQPFLR
k OPERATIONAL QUALITY ASSURANCE MANUAL
-TITLE: HANDLING, STORAGE AND SHIPPING 13.0 HANDLING, STORAGE AND SHIPPING
-13.1 PURPOSE This Policy describes the Operational Quality Assurance Program measures to control the handling, storage and shipping of safety-related materials, components and systems for the Grand Gulf Nuclear Station.
13.2 SCOPE This Policy delineates responsibilities and defines requirements for handling, storage and shipping, including cleaning, packaging and i
preservation of safety-rel r ed items in order to assure that the requisite quality of the items is maintained until they are used or incorporated into the nuclear power plant.
13.3 APPLICABILITY The requirements of this Policy apply to all individuals or organizations participating in the cleaning, handling, packaging, preservation, shipping and storage of safety-related items during the operational phase of nuclear power plant activities.
13.4 RESPONSIBILITY 13.4.1 During the operational phase at GGNS, the responsibility and authority for control of handling, storage and shipping,-including cleaning and preservation, are delegated to the General Manager, Plant Operations. During r
the implementation of. design changes and plant modifications, the. Manager, Plant Modification &
11 Construction is responsible for these activities.
They are responsible for assuring that procedures are established to address the applicable requirements of this Policy and that work and inspection activities are accomplished in accordance with the established procedures.
13.4.2 Organizations supplying safety-related material, equipment and services are responsible for complying with the applicable requirements of this Policy, as stipulated in the procurement documents, and for imposing them on their contractors and suppliers as applicable.
They are also responsible for verifying, through surveillance or audits, that the requirements are being adequately implemented.
0QAMR11.8/SQPFLR
OPERATIONAL QUAllTY ASSURANCE MANUAL TITLE: HANDLING, STORAGE AND SHIPPING 13.4 (Continued):
13.4.3 The Manager, Quality Services is delegated the responsibility for inspection of the control of handling and storage at GGNS includina during preoperational and startup testing.
The Manager, Quality Services is delegated the responsibility for warehouse-related inspection (including receipt inspection) of the control cf handling, storage and shipping at GCNS including during preoperational and startup testing.
The Manager, Quality Services is responsible for reviewing Plant Administrative 11 Procedures to verify conformance to the applicable requirements of this Policy.
13.4.4 The Director, Quality and the Manager, Quality have the responsibility for carrying out an audit program, as described in Policy 18.0 of this Manual, to verify conformance with the requirements of the Operational Quality Assurance Program, including the requirements of this Policy.
13.5 REQUIREMENTS 13.5.1 Procedures shall be established to control handling, storage and shipping, including cleaning, packaging and preservation of safety-related materials, components and systems.
The Procedures may be developed to cover generic classifications of items which require equivalent levels of protection and control during handling, storage and shipping. Classified items shall be restricted to that level or higher for each of the particular handling, storage and shipping operations; and a change in the classification of an item shall only be made in accordance with a written, engineering approved procedure.
13.5.2 The procedures shall be developed by the appropriate organizations to cover the various stages from fabrication or manufacture of the items to incorporation into the plant.
13.5.3 The procedures shall address the applicable design and regulatory requirements; codes and standards; and manufacturer's recommendatiens as approved by the licensee engineering personnel for the prevention of damage, deterioration or loss prior to installation or use.
Source quality verification or inspection operations necessary to verify conformance to the established criteria shall be included in procedures, and documentation of the verification activities shall be required.
Page 2 of 3 Policy 13 Rev. 11 0QAMR11.8/SQPFLR
0PERATIONAL QUALITY ASSURANCE MANUAL TITLE:
HANDLING,: STORAGE AND SHIPPING 13.5-(Continued):
13.5.4 Packaging and preservation procedures shall provide assurance of' adequate protection against corrosion, contamination, physical damage or any effect which would lower the quality of the item or cause it to deteriorate during shipping, handling or storage.
Special protective environments, special coverings, inert gas atmosphere, allowable moisture content, and temperature level shall be specified as' required and their existence verified and documented.
13.5.5 Cleaning procedures shall provide assurance that necessary cleaning operations are carried out prior to packaging, storage or installation.
The level of cleanliness required and verification and documentation requirements shall be specified in the procedures.
13.5.6 Procedures shall be provided to assure that proper marking and labeling'of items and containers is accomplished to provide identification and necessary instructions during packaging, shipment and storage.
13.5.7 Measures for receipt inspection of items, disposition of received-items and control of nonconforming items shall be addressed in procedures which implement the applicable requirements of Policies 7.0 and 15.0 of this Manual.
13.5.8 Detailed handling procedures shall be provided for all items that require special handling.
Speciai handling tools and' equipment shall be provided and controlled to ensure safe and adequate handling. These tools and equipment shall be maintained, inspected and tested in accordance with written procedures at established intervals to ensure their reliability and availability for use.
13.5.9 Storage procedures shall provide for methods of storage and the control of items in storage which will minimize the possibility of damage or deterioration during storage.
Periodic inspections of storage areas shall be performed and documented to verify compliance with storage procedures. Release of items for installation shall also be procedurally controlled.
13.5.10 This section deleted in Revision 11.
11 Page 3 of 3 Policy 13 Rev. 11 00AMR11.B/SQPFLR l
t
OPERATIONAL QUALITY ASSURANCE MANUAL TITLE:
INSPECTION, TEST AND OPERATING STATUS 14.0 INSPECTION, TEST AND OPERATING STATUS 14.1 PURPOSE This Policy describes the Operational Quality Assurance Program measures to identify and control the inspection, test and operating status of safety-related structures, systems and components for the Grand Gulf Nuclear Station.
14.2 SCOPE This Policy delineates responsibilities and defines requirements for a
identifying and controlling the inspection, test and operating E
status of safety-related items in order to assure that required inspections and tests are performed and the acceptability of items is known, and to prevent the inadvertent operation of items which are in a controlled status.
14.3 APPLICABILITY The requirements of this Policy apply to all individuals or organizations performing functions on safety-related structures, systems and components during the operational phase of nuclear power plant activities.
14.4 RESPONSIBILITY 14.4.1 During the operational phase, responsibility and authority for identifying and controlling the test and operating status of safety-related items, exciuding preoperational testing, are delegated to the General Manager, Plant Opera-tions. The Director, Quality has the responsibility and 11 authority for identifying and controlling the inspection, test, and operating status of safety-related items.
They are responsible for assuring that procedures are developed and implemented to address the applicable requirements of this Policy.
14.4.2 Organizations supplying safety-related material, equipment and services are responsible for complying with the applicable requirements of this Policy, as stipulated in the procurement documents, and for imposing them on their contractors and suppliers as applicable.
They are also responsible for verifying, through surveillance or audits, that the requirements are being adequately implemented.
14.4.3 The Manager, Quality Services is responsible for reviewing Plant Administrative Procedures to verify conformance to the applicable requirements of this Policy.
Page 1 of 3 Policy 14 Rev. 11 OQAMRll.8/SQPFLR
OPERATIONAL QUALITY ASSURANCE MANUAL l
TITLE:
INSPECTION, TEST AND OPERATING STATUS 14.4 (Continued):
14.4.4 The Director, Quality and the Manager, Quality have the g
responsibility for carrying out an audit program, as described in Policy 18.0 of this Manual, to verify conformance with Operational Quality Assurance Program requirements, including the requirements of this Policy.
14.5 REQUIREMENTS 14.5.1 Procedures shall be established and implemented by the organizations responsible for the fabrication, storage, installation, test, and operation of safety-related structures, systems and components to assure that the inspection, test and operating status of such items is identified, controlled and made known to affected organizations.
14.5.2 The procedures shall require that the status of inspections and tests be indicated by the use of appropriate status indicators such as stamps, tags, labels, routing cards, shop travelers, or other suitable means.
Suitable means may include identification numbers which are traceable to in:,pection and test records.
14.5.3 The procedures shall identify the status indicator to be used and provide for its control, including responsibility and authority for application and removal.
14.5.4 Bypassing of required inspections, tests or other critical operations shall be procedurally controlled with concurrence by Quality Programs. Where necessary to preclude inadvertent bypassing of required inspections and tests, the procedures shall provide for the identification
[
of items which have passed such inspections and tests.
14.5.5 In cases where documentary evidence is not available to confirm that an item has passed required inspections and tests, that item shall be considered nonconforming and processed in accordance with Policy 15.0.
Affected systems shall also be evaluated for operability in accordance with the Technical Specifications and reliance shall not be placed on any such systems (which are evaluated as incperable) to fulfill their intended safety functions.
14.5.6 Procedures shall be provided to require identification of the operating status of systems, components, controls, or support equipment in order to prevent inadvertent or unauthorized operation.
These procedures shall require control measures, such as locking or tagging to secure and identify equipment ;n a controlled status.
Independent verification shall be required, where appropriate, to en-sure that necessary measures, such as tagging equipment, have been implemented correctly.
Page 2 of 3 Policy 14 Rev. 11 OQAMRll.8/SQPFLR
OPERATIONAL QUALITY ASSURANCE MANUAL TITLE:
INSPECTION, TEST AND OPERATING STATUS 14.5(Continued):
14.5.7 Temporary modifications shall be controlled by approved procedures which include a requirement for independent verification. A log shall be maintained of the current status of such temporary modifications.
14.5.8 Nonconforming services and nonconforming, inoperative or malfunctioning structures, systems, components or materials shall be identified and controlled in accordance with the requirements of Policy 15.0 of this Manual.
0QAMRll.B/SQPFLR
~-
-OPERATIONAL QUALITY ASSURANCE MANUAL TITLE:
NONCONF0kM:hG 'iATERI ALS, PARTS OR COMPONENTS 15.0 NONCONFORMING MATERIALS, PARTS OR COMPONENTS (including items, Services and Activities) 15.1 PURPOSE This Policy describes the Operational-Quality Assurance Progran measures to identify and control safety-related items, services or activities for the Grand Gulf Nuclear Station which do not conform to established requirements.
15.2 SCOPE This Policy delineates responsibilities and defines requirements for the identification and contro! of nonconforming safety-related items, services or activities in order to assure that the nonconforming conditions do not compromise quality or safety.
15.3 APPLICABILITY The requi_rements of this Policy apply to all individuals or organizations performing functions on safety-related structures, systems, rnaterials, parts or components during the operational phase of nuclear. power plant activities.
15.4 RESPONSIBILITY 15.4.1 Responsibility and authority for the identification, control and disposition of nonconforming items, services 1
and activities during the operational phase are delegated to the Director, Design Engineering GGNS (for engineering); the Manager, Plant Modification &
Construction (for implementation of design changes _and plant modifications); the Manager, Fuel Fabrication (for nuclear fuel or core items); the General Manager, Plant 11 Operations; the Director, Quality; the Manager, Quality; and the manager of the organization performing the activity.
It is.the responsibility of these individuals to assure that the' requirements of this Policy which are ap-plicable_to their scope of activities are implemented in accordance with documented-procedures. All personnel are responsible for reporting detected nonconformances in ac-cordance with the procedures applicable to their particular organization.
15.4.2 Organizations supplying material, equipment or services are responsible for complying with the applicable requirements of this Policy, as specified in the procurement documents, and for imposing them on their contractors and suppliers, as applicable.
They are also responsible for verifying, through surveillance or audits, that the requirements are being adequately implemented.
Page 1 of 4 Policy 15 Rev. 11 0QAMR11.8/SQPFLR
0PERAT10NAL' QUALITY ASSURANCE MANU'AL'
-TITLE:
NONCONFORMING MATERIALS, PARTS OR COMPONENTS 15.4 (Continued):
15.4.3 The Manager, Quality Services is delegated the responsibii ity for' assuring implementation of the identification and control of nonconforming items, services and activities by review or receipt inspection activities during GGNS operational phase activities to verify conformance to the applicable requirements of this Policy. The Manager, Quality Systems is delegated the responsibility for assuring implementation of the identification and control 11 of nonconforming items, services and activities by audit of GGNS operations phase activities to verify conformance to the applicable requirements of this Policy.
The Manager, Quality Services is delegated the responsibility for control, processing, tracking, disposition concurrence, verification and closure of non-conformance documents for GGNS operations phase activities to verify conformance to the applicable requirements of this Policy.
11 15.4.4 The Director, Quality and the Manager, Quality have the responsibility for carrying out an audit program, as described in Policy 18.0 of this Manual, to verify conformance with the requirements of the Operational Quality Assurance Program, including the requirements of this Policy. They are also responsible for the periodic review and analysis of NRC and licensee quality deficiency documents to detect possible adverse quality trends.
15.5 REQUIREMENTS 15.5.1 Procedures shall be established by the responsible organizations-to identify and control nonconforming safetyrelated items, services and activities.
The procedures shall include provisions for identification, documentation, segregation, review, disposition and notification to affected organizations, as appropriate.
15.5.2 The procedures shall:
15.5.2.1 specify the individuals or organizations responsible for the disposition and approval of nonconforming items, services or activities, (including an independent review and acceptance by the-appropriate quality organization).
15.5.2.2 provide for documentation to identify the item, service or activity; describe the nonconformance; document the disposition and inspection requirements; and provide signature approval of the disposition.
Page 2 of 4 Policy 15 Rev. 11 0QAMR11.8/SQPFLR
OPERATIONAL QUAllTY ASSURANCE MANUAL TITLE:
NONCONf0RiilNG MATERI ALS, PARTS OR COMPONENTS 15.5.2 (Continued):
Unless evaluated as having no impact on satisfactory per-formance, nonconformances are corrected or resolved prior to the initiation of the preoperational test program on the item.
15.5.3 Measures shall be established to procedurally control further processing, delivery or installation of a nonconforming item or continuation of a nonconforming service or activity, pending a decision on its disposition.
15.5.4 In order to prevent its inadvertent use or installation, a nonconforming item shall be identified by marking or tagging and shall be physically seg epted, where c
practical.
If physical segregation is not practical, identification of the. tem as nonconfi ' ming by marking or tagging shall be acceptable. Where cking or tagging is not feasible, nonconforming items may be controlled by the use of appropriate documentation. Markings or tags used to identify nonconforming items shall be removed after resolution of the nonconforming condition.
15.5.5 Nonconforming items, services or activities shall be reviewed and dispositioned in accordance with documented procedures.
Items may be dispositioned in the following ways:
15.5.5.1 Accept-as-is; 15.5.5.2 Scrap; 15.5.5.3 Rework to conform to a drawing or specification; 3
15.5.5.4 Repair in accordance with an engineering approved procedure.
Items received without the necessary documentation shall be controlled. Acceptance of such items will be withheld pending receipt of required documentation or the items will be considered nonconforming.
15.5.6 The acceptability of rework shall be verified by reinspecting'or retesting the item to the original requirements, or by an equivalent method which has been reviewed and approved. The acceptability of repair shall be verified by reinspection, or retesting the item by an engineering approved method even though the item still may
_not conform to the original requirements.
Inspection, testing, rework and repair shall be documented.
Page 3 of 4 Policy 15 Rev. 11 4
OQAMR11.B/SQPFLR I
OPERATIONAL QUALITY ASSURANCE MANUAL
" TITLE:
NONCONFORMING MATERIALS, PARTS OR COMPONENTS 115.5(Continued):
15.5.7 For items dispositioned " accept-as-is" or " repair," a description of the change, waiver or deviation shall be documented to record the change and denote the as-built condition. Documentation verifying the acceptability and approval of such items shall also be required.
15.5.8 Nonconformance reports with " accept-as-is" or " repair" dispositions submitted by contractors or suppliers shall be reviewed and concurred with by the designated individuals and shall.become a part of the inspection records to be submitted with the item.
15.5.9 Nonconformance reports shall be periodically reviewed and analyzed to detect possible adverse quality trends, and the results shall be reported to management for review and assessment.
)
(
Page 4 of 4 Policy 15 Rev. 11 OQAMR11.8/SQPFLR
TOPERATIONAL QUALITY ASSURANCE MANUAL
-TITLE: CORRECTIVE ACTION 16.0 CORRECTIVE ACTION 16.1 PURPOSE This Policy describes the Operational Quality Assur wce Program measures to provide for the correction of conditions hdverse to the quality or safety of the Grand Gulf Nuclear Station.
16.2 SCOPE This Policy delineates responsibilities and defines requirements for the identification, documentation, reporting, and correction of conditions adverse to quality or safety, including requirements for the determination of cause and corrective action to preclude the recurrence of significant conditions adverse to quality or safety.
16.3 APPLICABILITY The requirements of this Policy apply to all individuals or organizations performing functions which affect safety-related structures, systems or components during the operational phase of nuclear power plant activities.
16.4 RESPONSIBILITY 16.4.1 Responsibility and authority for the development and control of measures to assure corrective action during the operational-phase are delegated to the General Manager, Plant Operations; Director, Design Engineering GGNS; Direc-tor, Nuclear Support; Director, Nuclear Engineering Analy-sis; Director, Nuclear Safety and Regulatory Affairs; Manager, Quality; Director, Materials, Purchasing and 11 Contracts; Director, Central Licensing; Director, Business Services; Director, Maintenance Support; and the Director, Quality. They are responsible for assuring that procedures are established in accordance with the requirements of this-Policy to provide for the identification, documentation, and correction of conditions adverse to quality or safety.
They are also responsible for assuring that corrective ac-tion implemented is designed to prevent recurrence of sig-nificant adverse conditions.
16.4.2 All organizations performing quality or safety affecting activities are responsible for incorporating into the appropriate procedures, measures for identi'.ying and reporting conditions which may warrant corrective action.
Responsibility for determining and implementing necessary corrective action is delegated to the organization performing or controlling the activity. During the operational phase, the responsibility for the 11 determination and implementation of corrective action onsite, is delegated to the General Manager, Plant Operations.
00AMR11.B/SQPFLR
_~
OPERATIONAL QUALITY ASSURANCE MANUAL i
TITLE: CORRECTIVE ACTION 16.4.2 (Continued):-
During implementation of design changes and plant modi-fications, the Manager, Plant Modification & Construction is responsible for this activity.
l11 16.4.3 This section deleted in Revision 4.
16.4.4 Organizations supplying material, equipment or services are responsible for complying with the requirements of this Policy as specified in the appropriate procurement documents, and for imposing them on their contractors and suppliers as applicable. They are also responsible for verifying, through surveillance or audits, that the requirements are being adequately implemented.
16.4.5 The Director, Quality and the Manager, Quality have the 11 responsibility for carrying out an audit program, as described in Policy 18.0 of this Manual; to verify conformance with Operational Quality Assurance Program requirements, including the requirements of this Policy; for the periodic review and analysis of NRC and licensee quality deficiency documents to detect possible adverse quality trends; for reporting such items, if any, to the Vice President, Engineering; the Vice President, Operations GGNS; the Senior Vice President, Planning & Assurance; the Vice President, Administrative Services and Regluatory Affairs; and the Vice President, Operations Support for further action.
16.5 REQUIREMENTS 16.5.1 Procedures shall be established and implemented by the responsible organizations, consistent with the scope of their activities, to provide measures for the identification, documentation, reporting and correction of conditions adverse to quality or safety.
16.5.2 The procedures shall provide for the evaluation-of conditions such as nonconformances, failures, malfunctions, deficiencies, violations, deviations, reportable occurrences, 10CFR21 items, and defective material and equipment to determine the need for corrective action and to identify possible adverse quality trends.
16.5.3 The procedures shall require that action be promptly initiated and adequately documented by the responsible organization to correct the condition and to determine if action is necessary to preclude its recurrence.
0QAMRll.B/SQPFLR
OPERATIONAL QUALITY ASSURANCE MANUAL TITLE: CORRECTIVE ACTION 16.5(Continued):
16.5.4 The documentation to be used to report conditions adverse to quality or safety and request corrective action, and the appropriate distribution and control thereof, shall be specified in the procedures.
16.5.5 The procedures shall provide for follow-up reviews by the appropriate ort'nizations to verify proper implementation of the corrective action and to close out the documenta-tion.
16.5.6 for significant conditions adverse to quality or safety, the cause of the conditions, and the corrective action taken which is designed to prevent recurrence of the event shall be documented and reported to appropriate levels of Nanagement for review.
16.5.7 Nonconforming niaterials, parts and components (including items, services and activities) shall be identified, controlled and dispositioned in accordance with procedures which implement the requirements of Policy 15.0 of this Manual.
1
^
OQAMR11.8/SQPFLR
OPERATIONAL QUALITY ASSURANCE MANUAL Ti1LE:
QUALITY ASSURANCE RECORDS 17.0 QUAllTY ASSURANCE RECORDS 17.1 PURPOSE This Policy describes the Operational Quality Assurance Program i
measures for the collection, storage, and maintenance of quality assurance records for the Grand Gulf Nuclear Station.
17.2 SCOPE This Policy delineates responsibilities and defines requirements for the development of a records management system to provide for the collection, storage, and maintenance of quality assurarice records.
Quality assurance records include those records which furnish documentary evidence of the quality of items and of activities affecting quality.
17.3 APPLICABILITY The requirements of this Policy apply to all individuals or organizations participating in the collection, storage or maintenance of quality assurance records during the operational phase of nuclear power plant activities.
17.4 RESPONSIBILITY 17.4.1 Responsibility and authority for the development of a records management system are delegated to the Vice President, Operations GGNS.
This includes responsibility for the collection, storage and maintenance of quality assurance records generated during design and construction, as well as during the operational phase.
He shell assure that records are collected, stored and maintained in accordance with procedures which address the requirements of this Policy.
Responsibility for the development of the required procedural controls for the collection, storage and maintenance of qualiti assurance records is delegated to the Generel Manager, F'. ant Operations.
17.4.2 The General Manager, Plant Operations is responsible for the collection, storage and maintenance of records gen-erated onsite and required to be maintained at GGNS 11 including GGNS records generated by the Plant Modification and Construction Section.
Such records include those necessary to operate and maintain the facility and meet regulatory requirements. Such records shall be identified in the appropriate Plant Staff Procedures or the Plant Modification and Construction Section Procedures oeveloped to meet the requirements of this Policy.
Page 1 of 3 Policy 17 Rev. 11 0QAMR11.8/SQPFLR
. ~.
- OPERATIONAL QUALITY ASSURANCE MANUAL
-TITLE: QUALITY ASSURANCE RECORDS a
17.4 (Continued):
17.4.3 The Manager, Quality-Services and the Manager, Quality Systems are delegated the responsibility for assuring im-plementation of the collection, storage, and maintenance of those quality assurance records onsite which are under the control of the General Manager, Plant Operations.
The Manager, Quality Services is responsible for reviewing Plant Administrative procedures and work documents for and performing inspections to the extent necessary to verify conformance to the requirements of this Policy.
17.4.4 The General Manager, Plant Operations is responsible for the collection, storage and maintenance of records related to GGNS.
Records to be maintained by the General Manager, Plant Operations shall be identified in the
-aapropriate-Administrative Procedures developed to meet t1e requirements of this Policy.
17.4.5 The-Director, Quality is responsible for the collection 37 and storage of quality assurance records generated by Quality Programs until such time as they are M nsmitted to the General Manager, Plant Operations, c'c.o records shall be _ identified in the appropriate Quality Assurance Procedures-developed to meet the requirements of this Pol'i cy.
17.4.6 Other organizations whose scope of activities require the generation, collection, storage or maintenance of quality assurance records shall establish procedures to assure compliance with the applicable requirements of this Policy. Contractors and suppliers are responsible for complying with the requirements of this Policy to the extent specified in_the appropriate procurement documents,
- and for imaosing them on their contractors and suppliers, as applica)le.
They are also responsible for verifying, through surveillance or audits, that the requirements are being adequately implemented.
17.4.7 The Director, Quality and the Manager, Quality have the 11 responsibility for carrying out an audit program, as described in Policy-18.0 of this Manual, to verify conformance with Operational Quality Assurance Program requirements, including the requirements of this Policy.
17 5 REQUIREMENTS L
17.5.1 A system for the collection, storage and maintenance of l
quality assurance recor<is including provisions for identification, classification, indexing, retention, preservation, safekecping, retrievability and disposition shall be established, f
b Page 2 of 3 Policy 17 Rev. 11 OQAMR11.B/SQPFLR o
l t
OPERATIONAL QUALITY-ASSURANCE MANUAL TITLE: QUALITY ASSURANCE RECORDS-17;5 (Continued):
17.5.2 The records system shall define requirements and responsibilities for records transmittals, retention, and maintenance, subsee,uent to the completion of a work activity, consistent with applicable codes, standards and procurement documents. Measures to assure that the required records have been received and are acceptable shall be established.
17.5.3 The records system shall provide measures to assure that records are identifiable and retrievable.
Retention periods of sufficient duration to assure the ability to reconstruct significant events and satisfy regulatory or statutory requirements shall be specified.
Inspection and u
test records shall contain the following v.here applicable.
17.5 3.1 A description of the type of observation; 17.5.3.2 Evidence of completing and verifying a manufacturing, inspection, or test operation; 17.5.3.3 The date and r suits of the inspection or test;
-17.5.3.4 Information related to conditions adverse to quality; 17.5.3.5 Inspector or data recorder identification; 17.5.3.6-Evidence as to the acceptability of the results.
17.5.4 Storage facilities for quality assurance records shall be designed to prevent records' damage or loss, to the maximun extent practical; or as a satisfactory alternative, duplicate record shall be stored in a separate remote location.
17.5.5 Records and documentation requirements are specified in the other Policies of this Manual. Quality assurance records include, but are not limited to: design records,
.such as specifications and drawings; procurement documents; operating logs and procedures; principal maintenance and modification documents; results of reviews, inspections, tests, audits, material analyses; monitoring of work performance; personnel, procedures, and equipment qualification records; quality deficiency documents; corrective action documents; and 10CFR evaluations (i.e.,
10CFR50.59,10CFR21).
0QAMR11.B/SQPFLR
OPERATIONAL QUALITY ASSURANCE MANUAL TITLE: AUDITS 18.0 AUDITS 18.1 PURPOSE This Policy describes the Operational Quality Assurance Program measures to provide a comprehensive audit program for the Grand Gulf Nuclear Station.
18.2 SCOPE This-Policy delineates responsibilities and defines requirements for the de'elopment and implementation of a comprehensive program of planned and documented audits designed to verify compliance with, and_ assess the effectiveness of, the Operational Quality Assurance Program.
18.3
' APPt.lCABILITY The requirements of this Policy apply to all internal and external audits performed by or for the licensee during the operational phase of nuclear power plant activities.
18.4
-RESPONSIBILITY 18.4.1 Responsibility and authority for the licensee's audit program are delegated-to the Director, Quality and the Manager, Quality.
They are responsible for the development 11 and implementation of.a program of planned and documented audits to verify compliance with all aspects of the Operational Quality Assurance Program and to assess its effectiveness. _They are responsible for assuring that procedures are developed, in.accordance with the recuirements of this Policy, to provide for both internal anc. external audits. The Director, Quality is responsible
'for performance of audits to verify plant conformance to the-Technical Specifications; audits _of operational phase 11 activities; and audits of. contractors and suppliers per-forming onsite activities.
The Manager, Quality is responsibile for the performance of audits of contractors and suppliers performing offsite-activities. They shall also_ assure that audit results are documented and reported to appropriate management, and that prompt corrective action is taken-to eliminate conditions adverse to quality detected during the course of audits.
18.4.2 This section deleted in Revision 3.
Page 1 of 4 Policy '5 Rev. 11 0QAMR11.8/SQPFLR
OPERATIONAL QUALITY _ ASSURANCE MANUAL TITLE: AUDITS 18.4 (Continued):
18.4.3 Organizations supplying material, equipment or services are responsible for auditing their internal operations and their contractors ed suppliers, as stipulated in the appropriate procurement documents, in order to verify 4
compliance with the quality assurance program requirements specified in the procurement documents.
18.4.4 The section deleted in Revision 5.
- 18.5-REQUIREMENTS 18.5.1 A comprehensive program of planned and documented audits shall be established and implemented by Quality Programs, Services Quality Assurance and Supplier Quality Assurance 11 to verify compliance with all aspects of the Operational
_ Quality Assurance Program.
The audit program shall be car-ried out in accordance with written approved procedures which address the requirements of this Policy.
18.5.2 The audit program shall provide for both internal and external audits.
Internal audits shall include audits of the procedures and performance of all licensee organizations whose activities affect the quality of safety-related structures, systems and components.
External audits shall include audits of the practices, procedures and instructions of contractors and suppliers who provide safety-related material, equipment or services.
18.5.3 Audits shall provide an objective evaluation of. quality related practices, procedures, instruct _ ions, activities, and items; and review of documents and records.
18.5.4-Audits of_ operating plant activities shall include, as a minimum, those specif.ied in the Technical Specifications for the applicable nuclear generating station.
18.5.5 Audits shall be perfonned by trained, qualified personnel not having direct responsibilities in th'e areas being audited. Qualification and training requirements for auditors shall be established and documented and records of auditor qualifications shall be maintained and kept current. Personnel selected for quality assurance audit assignments shall have: experience or. training commensurate i with the scope, complexity, or special nature of the-activities to be audited.
18.5.6 An audit schedule shall be developed, maintained, reviewed and updated, as necessary.
The audit schedule shall address the following minimum requirements:
t Page 2 of 4 Policy 18 Rev. 11 0QAMR11.8/SQPFLR
~-
OPERATIONAL QUAllTY ASSURANCE MANUAL TITLE: AUDITS 18.5.6 (Continued):,,,
18.5.6.1 Auditing shall be initiated as early in the life of an activity as practical to assure timely implementation of quality assurance program re-quirements.
18.5.6.2 Audits shall be scheduled on the basis of the status and importance of the activities to be audited.
18.5.6.3 Those specified in the Technical Specifications for the applicable nuclear generating station.
18.5.7 Individual audits shall be performed in accordance with documented plans and checklists which describe the audit and provide for an objective evaluation of the status and adequacy of the areas being audited.
The " objective evaluation" referenced is not to be confused with the evaluation statement in ANSI N45.2.12 to which the licensee has provided a clarificatica.
See Appendix A.
18.5.8 Audit results, including conditions adverse to quality detected during the audit, shall be documented and reviewed with the supervisor or manager having responsibility in the areas audited. Distribution of audit reports shall include management of the audited organization and appropriate licensee management.
18.5.9 Management of the audited organizations shall be responsible for correcting conditions adverse to quality identified during an audit. They shall assure that corrective action is scheduled, accomplished as scheduled, and documented. The corrective action shall be designed to prevent the recurrence of significant conditions adverse to quality.
(See also Appendix A. Regulatory Guide 1.144, item 11.)
18.5.10 Deficient areas shall be reviewed or reaudited on a timely basis to verify implementation of corrective action.
18.5.11 Audit results shall be analyzed to detect adverse quality trends and to evaluate the effectiveness of the Operational Quality Assurance Program. Results of such analyses which indicate adverse quality trends shall be reported to appropriate management for review and assessment.
18.5.12 Records shall be generated and retained for all audits, including individual audit plans, audit reports, written replies, and records of corrective action.
(See also Appendix A, Regulatory Guide 1.144, Item 13.)
Page 3 of 4 Policy 18 Rev. 11 00VtR11.8/SQPFLR
OPERATIONAL QUALITY ASSURANCE MANUAL TITLE: AUDITS 18.5 (Continued):
j 18.5.13 The licensee interprets the requireinents of Technical Specification 6.5.2.8, which requires that audits shall be performed under the cognizance of the SRC, to be met by the following:
The SRC shall review the results of audits of nuclear activities conducted in accordance with the GGNS Operational Quality Assurance Program.
Audits shall be conducted and results shall be reviewed in the areas listed in Technical Specification 6.5.2.8.
Page 4 of 4 Policy 18 Rev. 11 00AMRll.8/SQPFLR
2 APPENDIX A Conformance of GGNS Operational Quality Assurance brogram tc NCRegulatory Guides and Ati5TTtandards In each of the ANSI standards, other documents (i.e., other standards, codes, regulations, tables, or appendices) required to be included as a part of the standard are either identified at the point of reference or are desr.ribed in a special ser. tion of the standard.
The specific applicability or acceptability of these listed standards, codes, regulations or appendices is either covered in other specific areas in the Operational Quality Assurance Program, including appendices, or such documents are not considered as Quality Assurance Program requirements, although they may be used as guidance.
]
" Personnel Qualificat;on and Training" (2nd Proposed 1
Revision 2) - Endorses ANSI /ANS 3.1 (Draft 12/79)
The Operational Quality Assurance Program complies with those requirements of i
Sections 1.0, 2.0, 3.0, 3.1, 3.2, 3.2.1, 3.2.2 3.2.3, 3.3, 4.0, 4.1, and 5
i 4.4.5 of ANSI /ANS 3.1 (Draft 12/79) that are applicable to Quality Programs (both onsite and offsite) with the following clarifications:
1)
With regard to the term " Bachelor's Degree" as used in 'he draft Standard, the following qualifications may be considered equivalent to a Bachelor's Degree:
a.
4 years of formal schooling in science or mqineering, b.
4 years of applied experience at a nucic-ar >.acility in the area for which qualification is sought, c.
4 years of. operational or technical experience / training in I
nuclear power, or d.
eny combination of the above totaling 4 years.
J)
With regard to Section 4.4.; of ANSI /ANS 3.1 (Draft 12/79) titled Quality Assurance:
The licensee will comply with Paragraph 4.4.5 as originally stated in ANSl/ANS-3.1 - 1978 which reads as follows:
At the time of initial core loading or assignment to the active position, the resporsible person shall have six years experience in the field of quality assurance, preferably at an operating-nuclear plant, or operations supervisory ex7erience.
At least one year of this six years experience shall 3e nuclear r
power plant experience in the overall implementation of the quality assurance program.
(This experience shall be obtained within the quality assurance organization.) A minimum of one year of this six years experience shall be'related technical-or academic training.
A. maximum of fcur years of this six years experience may be fulfilled by related technical or academic training.
The applicability of %is Guide / Standard to other personnel in the licensee's organization is addrc m in-other Sections of 'he fSAR and the Tecnnical Specifications of the i.idividual nuclear facilny, Page 1 of 37 Appendix A Rev. 11 0QAMR11.8/SQPFLR
" Quality Group Classification, and Standards for Water, Steam, and Rad F Etive Waste Containing Components of Nuclear Power Plants (Rev. 3, 2/ 6) i The Operational Quality Assurance Program complies with the requirements of this Guide with the following clarification:
The licensee may choose not to use the specific A, B, C and D level classificatie. system set forth in this Guide.
The licensee generally followed tne requirements of this Guide in developing the list of structures, to which the program will apply.
The systems and components ("Q" List)he items to which the Operational Quality licensee "Q" List will describe t Assurance Program will apply in lieu of the guidance contained in this Regulatory Guide.
NRC Regulator Gu;de 1.28
" Quality Assurance Program Requirements (Design and Construction)y'T/72) - Endorses ANSI Ni5.2 - 1971.
This Guide and the Standard it endorses have been superseded for operations activities by Regulatory Guide 1.33 and ANSI N18.7 - 1976 whh.h it endorses.
The Operationa! Quality Assurance Program complies with Regulatory Guide 1.33 and ANSI N18.7 - 1976 as stipulated in Appendix A to that Program; therefore, Regulatory Guide 1.28 (Safety Guide 28) and ANSI N45.2 - 1971 which it endorses are not considered necessary and are not included as part of the Program.
NRC Regulatory Guide 1.29 "Seismi; Pasign Classification" (Rev. 3, 9/78) ihe Operational Quality Assurance Drogram complies with the requirements of this Guide with the following clarification:
for operations phase maintenance and modification activities which are comparoole in nature and extcnt to similar activities conducted during the construction phase, The licensee shall either control these activities under this Operational Quality Assurance Program or under an NRC accepted Construction Quality Assurance Program (per 0QAM 3.5.18). When this Operational Quality Assurance Program is used, the licensee shall comply with the Regulatory Position established in this Regulatory Guida in that Quality Assurance programmatiU administrative requirements included therein shall apply to these maintenance and modification activities even though such requirements may not have been in effect originally.
Technical requirements associated with the maintenance or modification shall be the original requirements or better (e.g., code requirements, material properties, design margins, manufacturing processes, and inspection requirements).
" Quality Assurance Requirements for the Installation, inspection, and Testing of Instrumentation and Electric Equipment" (8/72) - Endorses ANSI N45.2.4 - 1972.
Page 2 of 37 Appendix A Rev. 11 0QAMRll.8/SQPFLR
.NRC Regulatory Guide 1.30 (Continued):
The Operational Quality Assurance Program complies with the requirements of this Guide with the following clarifications:
.1) for operations phase maintenance 6nd modification activities which are comparable in nature and extent to similar activities conducted during the construction 3hase, the licensee shall either rontrol these activities under 111s Operational Quality Assurance Program or 4
under an NRC accepted Construction Quality Assurance Program (Per 00AM 3.5.18). When this Operational Quality Assurance Program is used, the licensee shall comply with the Regulatory Pos_ition established in this Regulatory Guide in that Quality As:,urance programmatic / administrative requirements included therein (subject to the clarifications in item 2 below) shall a> ply to these maintenance and modification activities even t1ough such re. +?ments may not have been in effect originally.
Technical requiren associated with maintenance and modifications shall be the v >tnal u
requirements or better (e.g., code requirements, material ar0certies, design margins, runufacturing processes, and inspection requirements).
2)
Additional clarifications for ANSI N45.2.4 - 1972 are indicated for I
specific sections below.
Section 1.4 - Definitions in this Standard which are not included in ANSI N45.2.10 will be used all definftions which are included in ANSI N45.2.10-will be used as clarified in the licensee commitment to Regulatory Guide 1.74.
Section 2.1 - Plar,aing requirements, when necessary, will be incorporated into meintenance and modification procedures.
Section 2.3 - Procedures and Instructions will be implemented as set
-forth in Policies 2, 3, 5, F0, ancTTI of the Operational Quality Assurance Program and by compliance with the individual nuclear facility Technical Specifications and ANSI N18.7 as set ' orth in Appendix A to that Program in lieu of the requirements set forth Sre.
Section 2.4 - Results will be implemented as-set forth in Policies 10, 11 and 17 of the Operational Quality Assurance Program and by compliance with ANSI N18.7 as set forth in Appendix A of that
+
Program in lieu of the requirement = set forth here.
Section 2.5.2 - Calibration and Control.
The third sentence of this
~
section states fiipart, ".., equipment shall be suitably marked to indicate date of next required calibration." The licensee will utilize a computerized system to indicate the calibration status of installed operations measuring and test equipment in lieu of marking or tagging the individual item.
00AMR11.B/SQPFLR
NRC R gulatory Guide 1.30 (Continued):
Section 3 - Preconstruction Verification will be implemented as fol-lows:
(1) iUegi4Tredl61v f5rTn53ITiHtions; (2) will be implement-ed with the clarification
.at " approved instruction manuals" shall be interpreted to mean the manuals provided by the supplier as re-quired by the procurement order--these manuals will not be reviewed and approved, per se, by the licensee; (3) no special checks will be made by the person withdrawing a replacement part from the ware-house--equivalent controls are assured by compliance with ANSI N45.2.2 as set forth in Appendix A to the Operational Quality Assur-ante Program; and, (4) will be complied with as stated, by individual technicians as part of the maintenance / modification process.
Section 4 - Installation will be implemented by inclusion, as neces-sary, in the appropriate maintenance or modification procedure, where such procedures are used.
Standard licensee maintenance practices recuire that care be exercised in the six areas listed whether a pro-cecure is required or not.
Section 5.1 - _ Inspections, including subsections 5.1.1, 5.1.2, and the first sentenceT5~l.3, will be implemented as set forth in Policy 10 of the Operational Quality Assurance Program.
The inspection arogram will incorporate, as applicable, those items listed in taese subsections. The remaining sentence in 5.1.3 is covered in equivalent detail in the licensee's commitment to ANSI N18.7, Section 5.2.6; the requirements as set forth in that commitment will be implemented in lieu of the requirements stated here.
Section 5.2 - Tests, 'ncluding subsections 5.2.1 through 5.2.3, will ba implemented as set forth in Policies 3 and 11 of the Operational Quality Assurance Program.
The test program will consider the elements outlined in this Section, where applicable, when developing test requirements for inclusion in maintenance and modification prochlures, in some cases, testing requirements may be met by post-installation surveillance testing in lieu of a special post installation test.
Section 6 - Post-Construction Verification is not generally considered applicable at operating fic~iTities because of the scope of the work and the relatively short interval between installation and operation. Where considered applicable, as in modificatioris, the elements described in this Section will be cemidered in the development and implementation of inspection and testing programs as described in Policies 3, 10 and 11 of the Operational Quality Assurance Program.
With regard to Section 6.2.1 of ANSI N45.2.4 - 1972 titled Equipment Te -
The last paragraph of this Section deals with tagging and l a_s_t s :beTing.
The licensee will comply with an alternate last paragraph which reads:
"Each safety-related item of process instrumentation is identified with a unique number.
This number is utilized in instrument maintenance records so that current calibration status, Page 4 of 3/
Appendix A Rev. 11 OQAMRil.8/SQPFLR
NRC Regulatory Guide 1.30 - Section 6 (Continued):
including data such as the date of the calibration and identity of person that performed the calibration, can be readily detennined.
Such information may also be contained on tags or labels which may be attached to installed instrumentation."
Section 7 - Data Analysis and Evaluation will be implemented as stat-ed herein after adding the clarifying phrase "where used" at the be-ginning of that paragraph.
Section 8 - Records will be implemented by conformance with Policy 17 of the 0perational Quality Assurance Program and ANSI N45.2.9 as set forth in Appendix A to that Program.
" Quality Assurance Program Requirements (Op-erationJ"TRev.2,273T-EndorsesANSIN18.7-1976.
The Operational Quality Assurance Program complies with the requirements of this Guide with the following clarifications:
N18.7 which it references)y Guide 1.33 (and Section 4.3.4 of ANSIwill be Paragraph C.3 of Regulator 1) appluable nuclear facility Technical Sp'ecifications which define
" Subjects Requiring Independent Review.
2)
Paragraah C.4.a of Regulatory Guide 1.33 (and Section 4.5 of ANSI N18.7 w1ich it references) will be implementea as required by the a)plicable nuclear facility Technical S)ecifications which define t1e " Audit Program" to be conducted.
T1e audit program is further defined and will be implemented as required by the commitment to ANSI'N45.2.12 as stated in Appendix A of the Operational-Quality J
. Assurance Program.
3)
Paragra)h C.S.a of Regulatory Guide 1.33 (and Section 4.4 of ANSI N18.7 w1ich it references) will be implemented with the clarification that the Plant Safety Review Committee shall perform this activity.
4)
Paragraph C.5.d of Regulatory Guide 1.33 (and Section-5.2.7.1 of ANSI N18.7 which it references) will be implemented by adding the clarifying >hrase "Where practical" in front of the fourth sentence should" in this sentence to "shall,1,ng of the two The Regulatory Guides chang ofthefift1 paragraph.
unnecessarily uses of the word restricts the licensee's options on repair or replace:r,ent parts.
It is not always practical-to test parts prior to use, for modifications where these requirements are not considered practical, l
a review in accordance with the provisions of 10CFR50.59 will be conducted and documented.
I i
Pag 5 of 37 Appendix A Rev. 11 0QAMRil.8/SQPrLR
l 1
NRC Regulatory Guide 1.33 (Continued):
5)
Paragraph C.S.e of Regulatory Guide 1.33 (and Section 5.2.13.4 of ANSI N18.7 which it references) will be implemented subject to the same clarifications made for ANSI N45.2.2 elsewhere in Appendix A to the Operational Quality Assurance Program.
6)
Paragraph C.S.f of Regulatory Guide 1.33 (and Section 5.2.19(2) of ANSI N18.7 which it references) will be implemented with the substi-tution of the word " practical" for the word "possible" in the last sentence.
7)
Paragraph C.S.
of Srulatory Guide 1.33 (and Section 5.2.19.1 of ANSI N18.7 whi h it ic?erences) will be implemented with the addition of the modifier normally" af ter each of the verbs (should) whicn the Regulatory Guido converts to "shall." It is the licensee's intent to fully comply with the requirements of this paragraph, and any condi-tions which do not fully comply will be documented and approved by-managementpersonnel.
In these cases, the reason for the exception shall also oc documented.
The documentation shall be retained for the same period of time as the affected preoperational test.
8)
With regard to Section 3.4.2 of ANSI N18.7 - 1975 titled Requirements for the Onsite Operating Organization:
Training standards referenced in this Section will be implemented if such standaro: are included in Appendix A to the Operational Quality Assurance Progren or in Techni-cal Specifications or are otherwise part of the license of the indi-vidual nuclear facility.
The licensee's method of docunenting and otherwise meeting the remainder of the requirements of zhis Section are set forth in Policies 1 and 2 of the Operational Quality Assur-ance Program and in the Technical Specifications of the individual nuclear facility.
9)
With regard to Section 4.1 of ANSI N18.7 - 1976 titled General:
The licensee audit program will be implemented in accordance witn and to meet the requirements of: ANSI N45.2.12 as endorsed in Appendix A; Policies 2, 16 and 18 of the Operational Quality Assurance Program; and the regairements of the individual nuclear facility Technical Specifications.
- 10) With regard to Section 4.2 of ANSI N18.7 - 1976 titled Program
==
Description:==
Two aspects are addressed in this Section:
audits and independent' reviews.
The independent review program is implemented as required by the Technical Specifications of the individual nuclear facility and by Policies 1 and 2 of the Operational Quality-Assurance Prcgram.
The licensee audit program will=be described in accordance with and to meet the requirements of ANSI N45.2.12 as endorsed in. Appendix A of the Operational Quality Assurance Program, r
I the requirements of the individual nuclear facility Technical l
Specifications, and Policies 16 and 18 of the Operational Quality Assurance Program.
I 0QAMR11.8/SQPFLR
NRC Regulatory Guide 1.33 (Continued):
- 11) With regard to Section 4.3 of ANSI N18.7 - 1976 titled independent Review Process:
The requir?ments of this Section, inclii3Iig iWof its subparts, shall be met by compliance with the Technical Specifi-Cdllons' requirements of the individual nuclear facility.
- 12) With regard to Section 4.5 of ANSI N18.7 - 1976 titled Audit Program:
The licensee audit program will be implemented in accordance witW~iiid to meet the requirements of:
ANSI N45.2.12 as endorsed in Appendix A; Policies 2, 16, 17 and 18 of the Operational Quality Assurance Program; and the requirements of the individual nuclear facility Technical Specifications.
- 13) With regard to Section 5.1 of ANSI N18.7 - 1976 titled Prog" ram De-scription:
Ihe fourth sentence in this Section required'a iUmmary document"; the licensee has submitted Appendix C to the Operational Quality Assurance Program and interprets this Appendix to fulfill the requirements for a summary document.
- 14) With regard to Section 5.2.2 of ANSI N18.7 - 1976 titled Procedure Adherence:
The temporary change requirements of this Section are delineated in the Technical Specifications for activities occurring after the Operating License (OL) is issued; the requirements of the Technical Specifications shall be used in lieu of the general re-quirements in this Section to control temporary changes.
For tempo-rary changes which occur under this Program during preoperational and startup testing prior to issuance af an OL, the licensee will comply with this Section with the clarification that another Test Supervisor or Shift Supervisor or other member of the Plant Staff (limited to Shift Superintendent, responsible Section Supervisor, Manager, Plant Operations; or General Manager, Plant Operations) knowledgeable in the areas affected by the change, may approve changes which require the signer to hold an SRO license.
When there is a requirement to " implement" or " address" a procedure, actions prescribed by procedures shall be accomplished.
This does not necessarily imply that in all cases the operator, engineer, or technician has a copy of the procedure in-hand and signs-off a checklist as each step or function is performed.
- 15) With regard to Section 5.2.6 of ANSI N18.7 - 1976 titled Eguipment Control: The licensee will comply with the " independent verification" requirements based on the definition of this phrase as given under our commitment to Regulatory Guide 1.74.
The third sentence of the fourth paragraph requires independent verification "when appropriate." Where significant exposure to radiation, which is determined by the cognizant Health Physics personnel, would result from such verification, they shall advise Operations of current radiological conditions-Operations will then decide whether or not the confidence gained from the independent verification is worth the additional radiation exposure.
In all cases, radiation doses will be As low As Reasonably Achievable (ALARA).
Page 7 of 37 Appendix A Rev. 11 OQAMRil.8/SQPFLR
NRC Regulatory Guide 1.33 - Section 15 (Continued):
Since the licensee sometimas uses descriptive names to designate equipment, the sixth paragraph, second sentence is replaced with:
" Suitable means include identification numbers or other descriptions which are traceable to records of the status of inspections and tests."
The first sentence in the eventh paragraph will be complied with after clarifying " operating personnel" to mean trained employees as-signed to, or under the control of, licensee management at an operat-ing nuclear facility.
16)
With regard to Section 5.2.7 of ANSI N18.7 - 1976 titled Maintenance and Modification:
Since some emergency situations could arise wM E might preB ude preplanning of all activities, the licensee will com-ply with an alternate to the first sentence in the second paragraph which reads:
"Except in emergency or abnormal operating c0nditions where immediate actions are required to protect the health and safety of the public, to protect equipment or personnel, or to prevent the deterioration of plant conditions to a possibly unsafe or unstable level, maintenance or modification of equipment shall be preplanned and performed in accordance with written procedures. Where written procedures would be required and are not used, the activities that were accomplished shall be documented after-the-fact and receive the same degree of review as if they had been preplanned."
for those system run-in activities that take place prior to issuance of an Operating License, the Startup Engineer may direct work by the licensee.
Oparations or Maintenance personnel to restore the system to design drawing requirements, provided the work and actions are properly doc-umented and that quality and engineering evaluations are cbtained.
These evaluations may be obtained after-the-fact.
- 17) With regard to Section 5.2.7.1 of ANSI N18.7 - 1976 titled Maintenance Programs:
The licensee will comply with the requirements of the first sentence of the fifth paragraph, where practical.
This clarification is needed since it is not always possible to promptly determine the cause of the malfunction, in all cases, the licensee will initiate proceedings to determine the cause, and will make such determinations promptly, where practical.
- 18) With regard to Section 5.2.8 of ANSI N18.7 - 1976 titled Surveillance Testing and Inspection Schedule:
In lieu of a " master surveillance schedule,"~ tee following requirement shall he complied with:
"A surveillance testing schedule (s) shall be established reflecting the status of all in-plant surveillance tests and inspections."
00AMR11.8/SQpFLR
NRC Regulatory Guide 1.33 (Continued):
- 19) With regard to Section 5.2.9 of ANSI N18.7 - 1976 titled Plant Security and Visitor Control:
The requirements of the indiv'idual nuclear facility Security Plan shall be implemented in lieu of these general requirements.
- 20) With regard to Section 5.2.10 of ANSI N18.7 - 1976 titled Housekeeping and Cleanliness Control:
The requirements of this Sec-tion beginning with the last sentence of the first paragraph and contInuingthroughtheendoftheSection,willbeimplementedas described in'the licensee's commitments to ANSI N45.2.3 and N45.2.1 as set forth in Appendix A to the Operational Quality Assurance pro-gram.
- 21) With regard to Section 5.2.13.1 of ANSI N18.7 - 1976 titled Procurement Document Control The words "the same" in the last sen-tence are replaced with the words "an equivalent".
- 22) With regard to Section 5.2.15 of ANSI N18.7 - 1976 titled Review, A) proval and Control of Procedures:
The third sentence in paragra Applicable procedures shall be re ph t1ree is interpreted to mean:
viewed following on accident, an unexpected transient, significant o)erator error, or equipment malfunction which results in a report-a)1e occurrence.
The first sentence in Paragraph four is interpreted to mean:
This requirement for routine followup review can be accom-plishedinseveralways, including (butnotnecessarilylimitedto):
-documented step-by-step use of the procedure (such as occurs when the procedure has a step-by-step checkoff associated with it), or de-tailed scrutiny of the procedure as part of a documented training program, drill, simulator exercise, or other such activity.
Grand Gulf Nuclear Station has taken exception to the biennial review arocess-because of programmatic controls that are equivalent to or
)etter than the biennial. review process for compliance with ANSI N18.7-1976.
These programmatic controls are effected in an effort to 33 ensure that procedures are reviewed for possible revision upon identification of new or revised source material potentially affecting the intent of procedures, thereby maintaining the arocedures current.
Entergy Operations believes that this approach setter addresses the intent of ANSI N18.7-1976 and is more acceptable from both a technical and a practical )erspective than a static two year-review process.
Procedures w1ich are only used infrequently, i.e., every three to five years, will be reviewed prior to use. A revision of a procedure constitutes a procedure review.
- 23) With regard to Section 5.2.17 of ANSI N18.7 - 1976 titled inspections:
Not all inspections will require generation of a sepa-rate inspection report.
Inspection requirements may be integrated into appropriate procedures or other documents with the procedure or document serving as the record._ However, records of inspections will be identifiable and retrievable.
0QAMR11.8/SQPFLR
-.a.--..-
i e
NRCRegulatoryGuide1.33(Continued):
- 24) With regard to Section 5.3.9 of ANSI N18.7 - 1976 titled Emergency Procedures:
As directed by the NRC, the licensee will follow a for-mat for emergency procedures which is " symptom" based as opposed to
" event" based as stipulated in Section 5.3.9.1.
Since the licensee will have these " symptom"_ based procedures, " event" based procedures will not normally be provided.
- 25) With regard to Section 5.3.9.2 of ANSI N18.7 - 1976 titled Events of Potential Emergency:
NRC review of the FSAR has identified all natu-ral occurrences which affect the nuclear facility.
Therefore, the licensee will interpret item (11) to mear the natural occurrences which have been evaluated in the FSAR for the individual nuclear fa-cility.
- 26) With regard to Section 5.3.9.3 of ANSI N18.7 - 1976 titled Procedures 1
for Im?lementing Emergency Plan:
The licensee's NRC accepted Emer-gency )lan for each nuclear facility will be implemented in lieu of the requirements in this Section.
- 27) With Regard to Sectic1 5.2.18 of ANSI N18.7 - 1976 titled Control of Special Processes:
The last four words of the first sentence are clarified by inserting the word " approved" before the word "proce-dure": We shall use qualified personnel and approved procedures.
- 28) With regard to Section 5.2.7 of ANSI N18.7.- 1976 titled Maintenance and' Modification:
The first sentence of the first paragraph could be interpreted to require the same degree of inspection for all mainte-nance activities as was provided during construction. When viewed in conjunction with Section 5.2.17, the third paragraph, we believe the actual intent is clear. We shall provide inspections comparable in nature and extent to that provided during construction if the mainte-nance / modification work is comparable in nature and extent.
- 29) With regard to Section 5-3.5(4) of ANSI N18.7 - 1976 titled Support-ing Maintenance Documents:
The licensee may choose to' include ma-terial from vendor manuals in any of three ways.
(1).The applicable section of the manual may be duplicated, referenced in, and attached to the procedure.
(2)Theproceduremaysimplystatethatthemanual or a specific section is to be followed for performing a ) articular function; the manual must then be used in conjunction wit 1 the proce-dure for performing the activity.
(3) The pertinent material from the manual, either as originally written or as modifieri by the au-thor / reviewers of the procedure, may be written into and become a
-Part of the procedure, in options, (1) and.(3) above, the material meets the requirement to receive "the same level of review and approval as operating proce-dures" since the material is reviewed as part of the procedurc review 3rocess.
In option (2), the requirements shall be deemed to lave been fulfilled by requiring a copy of the pertinent manual (man-ual sections) to be available to and considered by perscas conducting the review of the procedure.
Page 10.of 37 Appendix A Rev. 11 OQAMRll.8/SQPFLR
1 NRC Regulatory Guide 1.33 (Continued):
- 30) With regard to Section 5.2.16 of ANSI N18.7 - 1976 titled Measurin_3 and Test Equipment:
The second sentence of the third paragraph states " Records shall be made and equipment suitably marked to indi-cate calibration status." The licensee will utilire a computerized system to indicate the calibration status of installed operations measuring and test equipment in lieu of marking or tagging the indi-vidual item.
- 31) With reDard to Section 1 of ANSI N18.7 titled Scope: The fourth and fifth sentences state, "However, applicable sections of this standard should be used as they apply to related activities.
Activities 11 included are: Design Changes, Purchasing, fabricating...
The licensee does not intend to fabricate, design, assemble, or modify any NRC licensed container to be used to transport radioactive material.
" Quality Assurance Requirements for Cleaning of fluid Systems and AssocTated Components of Water-Cooled Nuclear Power Plants"
~
(3/73)EndorsesANSIN45.2.1-1973.
The Operational Quality Assurance Program complies with the requirements of this Guide with the following clarifications:
1 1)
With regard to Paragra)h C.3 of Regulatory Guide 1.37:
The water quality for final flusling of fluid systems and associated components shall be at least equivalent to the quality of the operating system water except for the oxygen and nitrogen content, but this does not infer that chromates or other additives, normally in the system wa-ter, will be added to th< flush water.
2)
With regard to Paragraph C.4 of Regulatory Guide 1.37:
Expendable materials, such as inks and related products, temperature indicating sticks, tapes, gummed labels, wrapping materials (other than Polyethelene), water soluble dam materials, lubricants, NDT penetrant materials and couplants, which contact stainless steel or nickel al-loy surfaces shall not contain lead, zinc, copper, mercury, cadmium and other low melting point metals, their alloys or compounds, as basic and essential chemical constituents.
Prescribed maximum levels of water leachable chlorides, total halogens, and sulphur and its compounds shall be imposed on expendable products.
3)
- With regard ~to Section 5 of ANSI N45.2.1 - 1973 titled Installation Cleaning:
The recommendation that local rusting on corrosion resis-tant alloys be removed by mechanical methods is inter)reted to mean that local rusting may be removed mechanically, but t1e use of other removal means is not precluded.
L L
OQAMR11.8/SQPFLR L
=-
..a
. =
, a _-,-..:_-
NRC Regulatory Guide 1.37 (Continued):
4) for operations phase maintenance and modification activities which are comparable in nature and extent to similar activities conducted during the construction phase, the licensee shall either control these activities under this Operational Quality Assurance Program or under an NRC accepted Construction Quality Assurance Program (Per 00AM 3.5.18). When this Operational Quality Assurance Program is used, the licensee shall comply with the Regulatory Position estab-lished in this Regulatory Guide in that Quality Assurance program-i matic/ administrative requirements included therein (Subject to the stated clarifications) shall apply to these maintenance and modifica-tion activities even though such requirements may not have been in effect originally. Technical requirements associated with the maintenance or modification !. hall be the original requirements or better (e.g., code requirements, material properties, design margins, manufacturing processes, and inspection requirements).
5)
With regard to Section 1.4 of ANSI N45.2.1 - 1973 titled Definitions:
Definitions in this Standard which are not included in AN5T~R S.2.10 shall be used; all definitions which are included in ANSI N45.2.10 shall be used as clarified in the licensee's commitment to Regulatory Guide 1.74.
6)
With regard to Section 9 of ANSI N45.2.1 - 1973 titled Records:
The licensee shall maintain records in accordance with and to meet the requirements of Policy 7 of the 00AM and ANSI N45.2.9 as specified in Appendix A.
7)'
Throughout this Standard, references are made to cleanness associated with initial installation. When this Standard is used for opera-tions, qualified supervisory maintenance personnel determine what items within a particular cleanness level are appropriate.
As an example, the Reactor Internals are initially classified as Level B.
Section 3.1.2 requires this cleanness level to have " metal clean" surfaces and either a visual inspection or= dry white-cloth wipe.
After use in the reactor coolant system, the licensee does not intend to clean a component until it has a bright " metal clean" surface, nor do we (from.an ALARA and accessibility considerations) intend to per-form a dry white-cloth wipe.
Components which have been removed from alant systems of established cleanliness levels may be considered to >e of the same cleanliness as the system from which they were removed.
Such components need not be recleaned prior to reinstallation provided that measures are taken to prevent degradation of the previously existing state of cleanliness, t
" Quality Assurance Requirements for Pekaging, Shipping, Receiving, Storage, and Handling of items for Water-Cooled Nuclear Power Plants" (Rev. 2, 5/77) - Endorses ANSI N45.2.2 - 1972.
The Operational Quality Assurance Program complies with the requirements of this Guide with the following clarifications:
0QAMRll.8/SQPFLR
1 I
s-I NRC Regulatory Guide 1.38 (Continued):
t 1)
With regard to Section 1.4 of ANSI N45.2.2 - 1972 titled Definitions:
l Definitions in this Standard which are not included in ANifl W 2~ID i
will be used; all definitions which are included in ANSI N45.2.10 will be used as clarified in the licensee's commitment to Regulatory Guide 1.74, 2)
With regard to Section 2.1 of ANSI N45.2.2 - 1972 titled Planning:
(first sentence) The specific items to be governed by the Standard shall be identified on the Q List.
However, the Standard (as modi-fied by the clarifications in Appendix A) is part of the Operational Quality Assurance Program and will, therefore, be applied to those structures, systems, and components which are included in that Pro-gram.
3)
With regard to Section 2.3 of ANSI N45.2.2 - 1972 titled Results: 1he specific methods for performing and documenting tests and inspections are given in Policies 10 and 11 of the Operational Quali-ty Assurance Program.
The requirements in these Policies will be implemented in lieu of the general' requirements here.
.4)
With regard to Section 2.4 of ANSI N45.2.2 - 1972 titled Personnel Qualifications:. Specific requirements for personnel qualifications and~ training are set forth in Policy 2 and in the commitments to training standards in Appendix A of the Operational Quality Assurance Program.
These requirements will be implemented in lieu of the gen-eral requirements stated in this Section.
5)
.With-regard to Section 2.7 of ANSI N45.2.2 - 1972 titled Classification of items: The licensee may choose not to explicitly use the four level classification system. However, the specific re-quirements of the Standard that are appropriate to each class will-generally be applied to the items suggested in each classification and.to similar items.
6)
With tegard to Section 3.2.1 of ANSI N45.2.2 - 1972 titled Level A Items:
As an alternate to the requirements _for packaging and con-tainerizing items-in storage to control contaminants (Items (4) and (5)), the licensee may choose a storage atmosphere which is free of harmful contaminants in concentrations that could produce damage to stored items.
Similarly (for item (7)) the licensee may obviate the need for caps and plugs with an appropriate storage atmosphere, and-may choose to protect weld end preparations and threads by control-ling the manner in which the items are stored.
These clarifications apply.whenever items (4), (5) or (7) are subsequently referenced and to Section 3.5.1 titled Caps and Plugs and Section 3&4 titled
' Methods of Preservation, t
u Page 13 of 37 Appendix A Rev. 11
-0QAMRll.8/SQPFLR
..m.
m.
NRC Regulatory Guide 1.38 (Continued):
7)
With regard to Section 3.3 of ANSI N45.2.2 - 1972 titled Cleaning:
(Third sentence) The licensee interprets " documented cleaning methods to allow generic cleaning procedures to be written which are imple-mented, as necessary, by trained personnel.
Each particular cleaning operation may not have an individual cleaning procedure, but the ge-neric procedures will saecify which methods of cleaning or which type (s) of solvent may se used in a particular application.
8)
With regard to Section 3.4 of ANSI N45.2.2 - 1972 titled Methods of Preservation:
(first sentence) The licensee will comply with these requirements subject to the clarifications of Section 3.2.1 (4) ion" and (5) above, and the definition of the phrase " deleterious corros to mean that corrosion which cannot be subsequently removed and which adversely affects form, fit, or function.
9)
With regard to Section 3.6 of ANSI N45.2.2 - 1972 titled Barrier and Wra) Material and Dessicants: This section requires the use of nonlalogenated materials in contact with austenitic stainless steel.
Refer to Regulatory Guide 1.37 above for the licensee's position.
10)
With regard to Section 3.7.1 of ANSI N45.2.2 - 1972 titled Containers:
Cleated, sheathed boxes may be used up to 1000 lbs.
rather tTan 500 lbs. as specified in 3.7.1(1).
This type of box is safe for, and has been tested for, loads up to 1000 lbs. Other national standards allow this (see federal Specification PPP-8-601).
Special qualification testing may be required for loads above 1000 lbs.
- 11) With regard to Section 3.7.2 of ANSI N45.2.2 - 1972 titled Crates and Skids:
Crates or skids will be used on equipment with a gross weight oT 9 0 lbs, or more.
Skids or runners will normally be fabricated from 2 X 4 inch nominal lumber size, minimum, and laid flat except where this is impractical because of the small dimensions of the con-tainer.
If forklift handling is required, minimum floor clearance for forklift tines will be provided.
- 12) With regard to Section 4.2.2 of ANSI N45.2.2 - 1972 titled Closed Carriers:
The use of fully enclosed furniture vans, as recommended in (2), of this Section is not considered a requirement.
The licensee will assure adequate protection from weather or other envi-ronmental conditions by a combination of vehicle enclosure and item packaging.
- 13) With regard to Sections 4.3, 4.4 and 4.5 of ANSI N45.2.2 - 1972 ti-tied, respectively, Precautions During Loading and Transit, Identification and Marking, and Shipment from Countries Outside the United States:
The licensee will comply with the requirements of these Sections subject to the clarifications taken to other Sections which are referenced therein.
-00AMR11.B/SQPFLR
=
.-a-..
~
NRC Regulatory Guide 1.38 (Continued):
- 14) With regard to Section 5.2.1 of ANSI N45.2.2 - 1972 titled Shipping Damage inspection: Warehouse personnel will normally visuaTiy scru-tinize incoming shipments for damage of the types listed in this Sec-tion, this activity is not necessarily performed prior to unloading.
Since all required items receive the Item inspection of Section 5.2.2, separate documentation of the Shipping Damage inspection is not necessary.
Release of the transport agent after unloading and the signing for receipt of the shi) ment may be all of the action tak-en to document completion of the 5iipping Damage inspection.
Any nonconformances noted will be documented and dispositioned as re-quired by Policy 15 of the Operational Quality Assurance Program. The person performing the visual scrutiny during unloading is not consid-ered to be performing an inspection function as defined under Regula-tory Guide 1.74; therefore, while he will be trained to perform this function, he may not-be certified (N45.2.6) as an Inspector.
- 15) With regard to Section 5.2.2 of ANSI N45.2.2 1972 titled item In-spection:
The second division of this subsection requires six addi-tional inspection activities if an item was not inspected or examined at the source.
The licensee will consider that a source inspection has been conducted if the supplier of the item is required to comply with ANSI N45.2.2 for the purchased item and if the supali-cr's program has been audited and found acceptable in t1e area (i.e., the supplier performs a source inspection of his supplier or conducts a receipt inspection that in-cludes, as applicable, the six additional items listed).
- 16) With regard to Section 6.1.2 of ANS! N45.2.2 - 1972 titled Levels of Storage:
Subpart (2) is replaced with the following:
(2)
Level B items shall be stored within a fire resistant, weather-tight, and well ventilated building or equivalent enclosure.
This building shall be situated and constructed so that it will not normally be subject to flooding; the floor shall be paved or equal, and well drained.
If any outside waters should come in contact with stored equipment, such equipment will be labeled or tagged nonconforming, and then the nonconformance document will be processed and evaluated in accordance with Policy 15.
Items shall be placed on pallets or shoring or shelves to permit air circulation.
The building shall be provided with heating and temperature control or their equivalent to reduce condensation and corrosion. Minimum temperature shall be 40*F and maximum temperature shall be 140*f or less if so stipulated by a manu-facturer.
- 17) With regard to Section 6.2.1 of ANSI N45.2.2 - 1972 titled Access to Storage Areas:
Items which fall within the Level D classification of the. standard will be stored in an area which may be posted to limit access, but other positive controls such as fencing or guards will not normally be provided.
_0QAMR11.8/SQPFLR
i NRC Regulatory Guide 1.38 (Continued):
- 18) With regard to Section 6.2.4 of ANSI N45.2.2 - 1972 titled Storage of Food and Associated items:
The sentence is replaced with the follow-ing: "The use or storage of food, drinks, and salt tablet dispensers in any storage area shall be controlled and shall be limited to des-ignated areas where such use or storage is not deleterious to stored items."
- 19) With regard to Section 6.2.5 of ANSI N45.2.2 - 1972 titled ficasures to Prevent Entrance of Animals:
The sentence is replaced wTth the T6TT5 sing:
" Warehouse personnel shall be alert to detect evidence of rodents or small animals in indoor storage areas, if any such evi-dence is detected, a survey or inspection will be utilized to deter-mine the extent of the damage; exterminators or other appropriate measures shall be used to control these animals to minimize possible contamination and mechanical damage to stored material."
- 20) With regard to Section 6.3.3 of ANSI N45.2.2 - 1972 titled Storage of Hazardous Material:
The sentence is replaced with the following:
" Hazardous chemicals, paints, solvents, end other materials of a like nature shall be stored in approved cabinets or containers which are not in close proximity to installed systems required for safe shut-down."
- 21) With regard to Section 6.4.2 of ANSI N45.2.2 - 1972 titled care of items:
The following alternates are provided for indicated subpart:
(1)
" Items in storage shall have all covers, caps, plugs or other closures intact, or shall be elevated to allow for proper drain-age. Methods used to seal openings shall be in accordance with Section 3 of this standard.
Covers removed for internal access at any time for any reason shall be immediately replaced and rescaled after completion of the purpose for removal."
(5)
" Space heaters in electrical equipment shall be energized unless a documented engineering evaluation determines that such space heaters are not required."
(6)
"Large (greater than or equal to 50 HP) rotating electrical equipment shall be given insulation resistance tests on a sched-uled basis unless a documented eng"ineering evaluation determines that such tests are not required.
(7)
"Prioi to being placed in storage, rotating equipment weighing over approximately 50 pounds shall be evaluated by engineering personnel to determine if shaft rotation in storage is required; the results of the evaluation shall be documented, if rotation is required, it shall be performed at specified intervals, be documented, and be conducted so that parts receive a coating of lubrication where applicable and so that the shaft does not come to rest in the same position occupied prior to rotation.
For long shafts or heavy equipment subject to undesireable bowing, shaft orientation after rotation shall be specified and ob-tained."
Page 16 of 37 Appendix A Rev. 11 0QAMRll.8/SQPFLR
NRC Regulatory Guide 1.38 (Continued):
- 22) With regard to Section 6.5 of ANSI N45.2.2 - 1972 titled Removal of items from Storage:
The licensee does not consider the lait sentence i
6T this Section to be applicable to the Operations Phase due to the relatively short period of time between installation and use.
The first sentence of the Section is replaced with:
" The licensee will develop, issue, and implement a procedure (s) which cover (s) the re-moval of items from storage.
The procedure (s) will assure that the status of all material issued is known, controlled, and appropriately dispositioned."
- 23) With regard to Section 6.6 of ANSI N45.2.2 - 1972 titled Storage Records:
The licensee will comply with the requirements of this Sec-tion with the clarification that, for record purposes, only the ac-cess of-personnel without Key Cards into indoor storage areas shall be recorded.
Unloading or pick-up of material shall not be consid-ered " access," nor shall in>pection by NRC or other regulatory ta ents, nor shall tours by non-licensee employees who are accompanied b licensee employees.
- 24) With regard to Section 7.3 of ANSI N45.2.2 - 1972 titled Hoisting Equipment:
Re-rating of hoisting equipment will be considered only when absolutely necessary.
Prior to performing any lift above the
-load rating, the equipment manufacturer must be contacted for his approval and direction.
The manufacturer must be requested to supply a document granting approval for a limited number of lifts at the new rating and any restrictions involved, such as nodifications to be made to the equipment, the number of lifts to be made at the new rat-ing, and the test lift load.
At all times, the codes governing re-rating of hoisting equipment must be observed.
NRC Regulatory Guide 1,39
" Housekeeping Requirements for Water-Cooled Nuc1 car Power Plants" (Rev. 2,1777) - Endorses ANSI N45.2.3 - 1973.
The Operational Quality Assurance Program complies with the requirements of l
this Guide with the following clarifications:
1)
For operations phase maintenance and modification activities which are comparable in nature and extent to similar activities conducted during the construction phase, the licensee shall either control L
these activities under this Operational Quality Assurance Program or under an NRC accepted Construction Quality Assurance Program (Per 0QAM 3.5.18).
-When this Operational Quality Assurance Program is used, the licensee shall comply with the Regulatory Position established in this Regulatory Guide in that Quality Assurance programmatic / administrative requirements included therein ~(Subject to the clarifications in item 2 below) shall apply to these maintenance and modification activities even though such requirements may not have been in effect originally.
Technical requirements associated with the maintenance or inodification shall be tra original requirements or better (e.g.,
code requirements, material properties, design margins, manufacturing process-es, and inspection requirements),
i l
Page 17 of 37 Appendix A Res. 11 l
0QAMRll.3/SQPFLR
NRC Regulatory Guide 1,39 (Continued):
2)
Specific clarifications for ANS1 N45.2.3 - 1973 are indicated for
-specific Sections below.
Section 1.4 - Definitions:
Definitions in this Standard which are not included in ANSI N W 2.10 will be used; all definitions which are included in ANSI N45.2.10 will be used as clarified in the licensee's commitment to Regulatory Guide 1.74.
Section 2.1 - planning:
The li nsee may choose not to utilize the fivelevel zone designation system, but will utilize standard janito-rial and work practices to maintain a level of cleanliness commensu-rate with Ccmpany policy in-the areas of housekeeping, plant and per-sonnel safety, ena fire protection.
Cleanliness will be mainteined, consistent with the work being per-formed, so as to prevent the entry of foreign material into safety-related systems. This will include, os a minimum, documented cleanliness inspections which will be performed prior to system closure.
Asnecessary.(e.g.,theopeningislargerthanthetools being used) control of personnel, tools, equipment, and 9tpplies will be established when major portions of the reactor system are opened for inspection, maintenance or repair.
Additional housekeeping requirements will be implemented as required for control of radioactive contamination.
i Section 2.2 - Procedures and Instructions:
Appropriate procedures will be written and implemented.
Section 3.1 - Control of_GGNS Area:
Not applicable to the Operations Phase.
i Section 3.2 - Control of facilities:
The licenree may choose not to utilize the five-level zone designation system, cut will utilize standard janitorial and work practices to in&dain a level of clean-
-liness commensurate _with Company poln.y in the areas of housekeeping,
_ plant and personnel safety, and fire protection.
Cleanliness will be maintained, consistent with the work being per-formed, so as to prevent the entry of foreign material into safety-4 related systems - This will include, as a minimum, documented clean-liness inspections which will be performed prior to system closure.
As necessary, (e.g., the opening -is larger than the tools being used) control of personnel, tools, quipment, and supplies will be estab-lished when major portions of the reactor system are opened for in-spection, maintenance or repair.
Additional-housekeeping requirements will be implemented ?s required
.for control of radioactive contamination.
Page 18 of 37
-Append 1x A Rey, 11
.00AMRll.8/50PFLR-
. ~. -, -,-
NRC Regulatory Guide __1.39 (Continued):
I Section 3.3 - Materials and Eguipment:
The first paragraph in this Section is not applicable to the Operations phase.
Section 3.4 - Construction Tools, Supplies, and_ Equipment:
Not ap-plicable to the Operations phase.
Section 3.5 - Surveillance. Inspection, and Examination: Subparagraph (1) is not 6pplicable to the Operations pilase; (2), (3J and (4) will be implemented.
Section 4 - Records:
The requirements of Policy 17 and ANSI N45.2.9 as set forth in Appendix A of the Operational Quality Assurance Pro-gram shall be implemented in lieu of the requirements of this Sec-tion.
]
Section 3.2.3 - fire Protection and Prevention:
The accepted fire
~
Protection Plan shall be used in lieu of the general requirements in i
this section.
" Qualifications of Nuclear Power Plant inspection, DIaiilnation, and Testing Personnel". (Rev. 1, 9/80) - Endorses ANSI N45.2.6
-1978Property "ANSI code" (as page type) with input value "ANSI N45.2.6</br></br>-1978" contains invalid characters or is incomplete and therefore can cause unexpected results during a query or annotation process..
The Operational Quality Assurance Program cunplies with the requirements of this Guide with the following clarifications:
1)
The licensee may choose not to apply the rcquirements of this Guide to those personnel who are involved in day-to-day operations, sur-veillance, maintenance and certain technical and support services whose qualifications are controlled by Technical Specifications or other Operational Quality Assurance Program commitment requirements.
2)
With-regard to Section 1.2 of ANSI N45.2.6 - 1978 titled Applicability:
The third paragraph requires-that the-Standard be used in conjunction with ANSI N45.2r "1e licenEe no longer specifically commits to ANSI N45.2 in the Operational Quality Assurance Program. The fourth 3aragraph requires that the Standard be imposed on personnel other taan licensee employees; the applicability of the Standard to suppliers will be documented and applied, as appropriate, in the procurement documents for such suppliers.
3)
With regard to Section 1.4 of ANSI N45.2.6 - 1978 titled Defiriitions:
Definitions in this Standard which are not included in AN3 FN13 T iD will be used; all definitions which are included in ANSI N45.2. 0 will be used as clarified in the licensee's commitment to Regulatory Guide 1.74.
- Page-19 of 37
. Appendix A Rev. 11
-. ~
NRC Regulatory Guide 1.58 (Continued):
4)
With regard to Section 2.5 of ANSI N45.2.6 - 1978 titled Physical:
The licensee will implement the requirements of this Section wFtT1 the stipulation that, where no special,nhysical characteristics are re-quired none will be specified.
The converse is also true:
If no specialphysicalrequirementsarestipulatedbythelicensee,none are considered necessary.
5)
With regard to Section 3.5 of ANSI N45.2.6 - 1978 titled Education and Experience - Recommendations:
The licensee reserves the riglit to use personnel who do not meet all the educational and experience re-quirements of this Section provided:
The use of personnel who do not meet these requirements shall be the exception rather than the rule and each such case shall receive a documentem management evaluation and justification for the exception. An example of a documented man-agement evaluation and justification would be one which includes ob-jective criteria (examination, review of actual work Performed) to demonstrate that equivalent competence is possessed by such an indi-vidual.
" Quality Assurance Requirements for the Design of Nuclear Power Plants" (Ev. 2, 6/76) - Endorses ANSI N45.2.11 - 1974.
The Operational Quality Assurance Program complies with the requirements of this Guide with the following clarifications:
1) for operations phase maintenance and modification activities which are comparable in nature and extent to similar activities conducted durint the construction phase, the licensee., hall either control these activities under this Operational Quality Assurance Program or under an NRC accepte' Construction Quality Assurance Program (Per 00AM 3.5.18). When this Operational Quality Assurance Program is used, the licensee shall comply with the Regulatory Position established in this Regulatory Guide in that Quality Assurance p;oorammatic/ administrative requirements included therein (subject to the clarifications listed below) shall a] ply to these maintenance and modification activities even though suca requirements may not have been in effect originally.
Technical requirements associated with maintenance and modifications shall be the original requirements or better (e.g., code requirements, material properties, design mar-gins, manufacturing processes and inspection requirements).
2)
With regard to Paragraph C.2(1) of Regulatory Guide 1.64:
If in an exceptional circumstance the designer s immediate Supervisor is the only technically qualified individual available, this review can be conducted by the Supervisor, providing that:
(a) the other provisions of the. Regulatory Guide are satisfied, and (b) the justification is individually documented and approved in advance by the Supervisor's management, and (c) quality assurance audits cover frequency and effectiveness of use of Supervisors as design verifiers to guard against abuse.
0QAMR11.B/SQPFLR
NRC Regulatory Guide 1.64 (Continued):
3)
With regard to Section 1.4 of ANSI N45.2.11 - 19/4 titled Definitions:
Definitions in this Standard which are not included in AWil N W l 10 will be used; all definitions which are included in ANSI N45.2.10 will be used as clarified in the licensee's commitment to Regulatory Guide 1.74.
4)
With regard to Sections 2.1 (last paragraph), 2.2 (Items 12 and 13),
Section 9, and Section 11 (including subsections 11.1 through 11.7) of ANSI N45.2.11 - 1974: The Licensee's Audit Program will be imole-mented in accordance with and to meet the requirements of:
ANSI N45.2.12 as endorsed in Appendix A: Policies 2, 3, 16 and 18 of the Operational Quality Assurance Progsam, and the requirements of the individual nuclear facility Technical Specifications in lieu of tl.e audit requirements stated in the referenced sections.
5)
With regard to Section 5.2.4 of ANSI N45.2.11 - 1974 titled Documen-tation:
for the documentation of interdisciplinary design reviews, there must be documented evidence of the acceptability of design doc-uments or portions thereof, prior to release (material, stress, phys-ics, mechanical, electrical, concrete,etc.).
The signature or ini-tials of those who determine the acceptability of the design relative to their respective disciplinary area of concern should be on the document or on a separate form traceable to the document.
A document that indicates the reviewer's comments need not be retained.
6)
The licensee does not require the SAR to be a design document.
How-ever, if the SAR contains any design or design input that has not been previously documented, reviewed and approved in accordance with the requirements contained in the 0QAM or another appro 3 design control Quality Assurance program and if the SAR is used as a design document diaring the design process, that specific information must i)e s
controlled and verified in accordance with the commitments here and Policy 3 of the 0QAM.
7)
With regard to Section 6.1 of ANSI N45.2.11 - 1974 titled General:
The third paragraph in this Section stipulates certain requirements relative to "the results of design verification". The licensee may comply with these recuirements by having the Reviewer (s) sign and date an appropriate cocument providing the following conditions are also met:
a)
Documente i engineering / design procedures are established which ccver the extent of design review.
b)
The procedures identify the duties of the Reviewer and the ex-tent of this responsibility for which he attests with his signa-
- ture, c)
The procedures specify the extent of documentation necessary for the type of design verification applicable to the complexity of l
the design.
OQAMRll.B/SQPFLR
NRC Regulatory Guide 1.64 - Section 7 (Continued):
d)
The signature and date is affixed in accordance with the proce-dures.
The licensee shall also pennit initials to be used in lieu of the signature required above If a file is maintained to correlate characteristic initials versus individuals such that each set of characteristic initials can be traced to an individual.
This correlation must be readily avail ble to NRC inspector whenever the document is being used.
8)
The timing of deilgn verification is not mentioned in the Standerd.
The licensee shall perform verification in a ti c ly manner, if other than by qualifications test:ng of a prototype or lead production unit, verification should be completed prior to release fer procure-ment, manufacturing or construction or release to another organiza-tion for use in other design activities.
In those cases where this timing cannot be met, the design verification may be deferred. pro-viding that the justification for this action is documented and the unverified portion of the design output document and all design out-put documents, based on the unverified data, are appropriately iden-tified and controlled.
Site GGNS activities associated with a design or design change shall not proceed without verification past the point where the installation would become irreversible without exten-sive demolition and rework.
In all cases, the design verification shall be completed prior to relying upon the component, system, or structure to perform its safety-related function.
9)
With regard to Section 10 of ANSI N45.2.11 - 1974 titled Records: The licensee shall maintain records in accordance with and to meet the requirements of Policy 17.0 of the OQAM and ANSI N45.2.9 as specified in Appendix A.
The additional requirements of the first sentence of the second paragraph in this Section shall also be met.
" Quality Assurance Terms and Definitions" (2/74)
Endorses AN5TWb'TTO - 1973.
The Operational Quality Assurance Program complies with the requirements of this Guide with the followina clarifications:
1)
The licensee reserves the right to define additional words or phrases which are not included in this Standard.
Such additional definitions will be documented in appropriate procedures and/or in attachments /
3ppendices to the Quality Assurance Procedures Manual, or in Policies of the Operational Quality Assurance Program.
See Policy 2, Para-graph 2.5.8.
1 Page 22 of 37 Appendix A Rev. 11 0QAMR11.B/SQPfl.R
hRC Regulatory Guide 1.74 (Continued):
2)
The licensee reserves the right to add additional words/ phrases to those definitions listed in this standard and other ANSI standards as necessary for clarification provided such clarification does not change the intent of'the definition. Additionally, the licensee considers the point of application to be the procedure in which the word / phase is defined and used. Also, the licensee considers words/ phrases defined in procedures, which are not otherwise defined, D
to be applicable only to the activity controlled under the procedure.
In addition to the Standard's definition of "Insaection", the licensee will use the following: " Inspection (W1enusedtoreferto activities that are NOT performed by Quality Programs' personnel) -
Examining, viewing closely, scrutinizing, looking over or otherwise checking activities. Personnel performing these functions are not necessarily certified to ANSI N45.2.6."
When the licensee intcods-for Inspections to be performed in accor---
dance with tne Operational Quality Assurance Program by personnel cerii, icd as required by that Program and for activities defined by
" Inspection" in ANSI N45.2.10, appropriate references to Quality Peo-grams which will perform the activity or to Quality Assurance Proce-dures/ Instructions to be used for performing the activity will be
- made, if such references are NOT made, inspections are to be consid-ered under the additional definition given above.
Inspections to meet the intent of 10CFR50 Appendix B are described in Policy 10 of the 0QAM.
3)
In addition to the Standard's definitica of " procurement documents",
the licensee will utilize the definitions given in ANSI N45.2.13 and in Regulatory Guide 1.74.
The compound definition is given as fol-lows: " Procurement documents - Contractually binding documents that identify and define the requirements which items or services must meet in order to be censidered acce) table by the purchaser.
They include documents which authorize t1e seller to perform services or supply equipment, material or facilities on behalf of the purchaser (e.g., contracts, letters of intent, work orders, purchase orders, 0:
proposals'and their a
.tance, drawings, specifications, or instruc-tions which define requirements for purchase)."
4)
" Program Deficiencies" (Not defined in ANSI N45.2.10, but used and defined in ANSI N45.2.12) - Failure to develop, document or implement ef fectively any applicable element of-the Operational Quality Assur-ance Program.
5)
" Quality Assurance Program Requirements" (Not defined in ANSI N45.2.10 but used and defined differently in AUSI NT5.2.13) Those individual requirements of the Operational Quality Assurance Program which, when invoked in total or in part, establish the requirements of the quality assurance program for the activity being centrolled.
Although not specifically used in the Operational Quality-Assurance Program, ANSI N45.2 may Le imposed uron the licensce's suppliers.
0QAHRll.8/SQPFLR.
1
~
,NRC Regulatory Guide 1.74 (Continued)
- 6) This section deleted in Revision 4,
- 7) " Independent Verification" - Verification by an individual other than the person who performed the operation or activity being verified that required actions have been completed.
Such verification will not require confirmation of the identical action when other indica-tions provide assurance or indication that the prescribed activity is in fact complete.
Examples include, but are not limited tot verifi-cation of a breaker opening by observing remote breaker indication lights;verificationofasetpoint(madewithavoltmeterorammeter for example) by observing the actuation of status or indicating lights at the required panel-meter indicated value, ve*4fication that a valve has been positioned by observing the starting or stopping of flow on meter indications or by remote value positions indicating lights.
- 8) "NRC accepted Construction Quality Assurance Program" - (1) a program for design or construction which was reviewed by the Quality Assur-ance organization of the NRC and accepted for use; (2) the revision of that NPC accepted program which is in effect at the time that the licensee authorizes commencement of work; and, (3) a program which the licensee's quality assurance organization reviews and concurs that the Quality Assurance Program controls are acceptable for the at.tivity to be performed.
(
Reference:
00AM 3.5.18)
- 9) "Special Processes" - Processes which 3re controlled and monitored in accordance with aparoved procedures where required quality levels cannot be assured )y inspection of the arocessed articles alone, or where it is more effective to control tle process than inspect the completed article.
10)
" Permanent Plant Device" (when used with respect to instrumentation)
- A device, permanently installed, which functions as a part of a system and.is used for monitoring a process veriable in the plant.
11)
" Concurrence" (when used with respect to and in association with a review activity) is defined to meant (1) a review of a docement or portion thereof under consideration; (2) a conclusion that all perti-nent and necessary requirements (within the purview of the or per-forming the review) have been included; and, (3) essential agreement and belief that the manner in which the requirements have been ad-dressed will produce the intended results.
42)
" Audits" (defined in ANSI N45.2.10 but used and defined differently in ANSI N45.2.12) Audit - A documented activity perfonned in accor-dance with written procedures or checklists to verify, by examination and evaluation of objective evidence, that applicable elements of the quality assurance program have been developed, documented and effec-tively implemented in accordance with specific requirements. An au-dit should not be confused with surveillance or inspection for the sole purpose of process control or product acceptance.
Page 24 of 37 Appendix A Rev. 11 PM
r NRC Regulatory Guide 1.88
" Collection, Storage and Maintenance of Nuclear Power PTant Quality Assurance Records" (Rev. 2, 10/76) - Encorses ANSI N45.2.9
- 1974Property "ANSI code" (as page type) with input value "ANSI N45.2.9</br></br>- 1974" contains invalid characters or is incomplete and therefore can cause unexpected results during a query or annotation process..
The Operational Quality Assurance Program complies with the requirements of this Guide with the following clarifications:
1)
With regard to Section 3.2.1 of ANSI N45.2.9 - 1974 titled Generation of Quality Assurance Records:
The phrase " completely filled out" is clarified to mean that sufficient information is recorded to fulfill the intended purpose of the record, and it is considered complete.
II Only complete records are considered QA records.
2)
With reg'ard to Section 3.2.2 of ANSI N45.2.9 - 1974 titled Index: The phrase an index"-is clarified to mean a collection of documents or indices which, when taken together, supply the information attributed to "an index" in the Standard.
1he specific location of a record within a storage area may not be delineated (e.g., The specific location within a computer record file may not be constant, further, the licensee may utilize a computer assisted random access, filing system where such location could not be readily " documented, nor would such a location be " relevant.") The 3
storage location will be delineated, but where file locations change with time, the specific location of a record within that file may not always be documented.
3)
With regard to Section 4.2 of ANSI N45.2.9 - 1974 titled Timeliness:
The licensee's contractual agreement with its contractors and suppli-ers will constitute fulfillment of the requirements of this Section.
4)
With regard to Section 5.4 of ANSI N45.2.9 - 1974 titled Preservation: The following clarification is substituted for the cur-rent subsection 5.4.2:
" Records shall not be stored loosely. They shall be secured for storage in file cabinets or on shelving in con-tainers."
'The following clarification it substituted for the current subsection 5.4.3: " Provisions shall be made for special processed records (such as radiographs, photographs, negatives, microfilm and magnetic media) to prevent damage from excessive light, stacking, electromagnetic fields, temperature and humidity as appropriate to the record type.
5)
With regard to Section 5.5 of ANSI N45.2.9 - 1974 titled Safekeeping:
Routine general office and nuclear site security systems and access controls are provided; no special security systems shall be estab-lished for record storage areas.
0QAMRll.8/SQPFLR-
NRC Regulatory Guide 1.88 (Continued):
6)
With regard to Section 5.6 of ANSI N45.2.9 - 1974 titled facility:
This Section provides no distinction between temporary and permanent facilities, To cover temporary storage, the following clarification is added:
" Quality Assurance records will be stored in one-hour fire rated file cabinets, in general, records shall not be maintained in 11 temporary storage for more than three months after completion. Any exceptions to this requirement must be evaluated and approved by the Director, Quality; a list of all such excepted records shall be maintained and available for NRC review.
Exceptions may include records needed on a continuing basis for an extended period of time (e.g., personnel qualification and training records, equipment history records) and records which are cumulative :n nature (e.g.,
nonconforming item logs)."
r Paragraph 4, subsection 3 is clari::ed to require a two-hour minimum fire rating to be consistent with.ae 1979 version of the Standard and NRC Criteria for Record Storage faciliti_es (Guidance-ANSI N45.2.9, lectionT6) issued 77f780.
Paragraph 4, subsection 9 is clarified to read:
"No pipes or pene-trations except those providing fire protection, lighting, tempera-ture/ humidity control, or commun notions are to be located within the facility. All such penetrations shall be sealed or dampered to com-ply with a minimum two-hour fire protection ratirg."
7)
With regard to Section 5.3 of ', col N45.2.9 - 1974 titled Storage:
The first sentence is clarified by stating that an individual shall be designated and assigned the responsibility for enforcement of written record storage procedures for each record storage location.
The term " custodian" may or may not be used as part of that designa-tion.
" Quality Assurance Requirements for Installation, inspection, and Testing of Structural Concrete and Structural Steel during the Construction Phase of Nuclear Power Plants" (Rev. 1, 4/76) - Endorses ANS!
N45.2.5 1974.
The Operational Quality Assurance Program complies with the requirements of this Guide with the following clarifications:
1)
For operations phase maintenance and modification activities which are comparable in nature and extent to similar activities conducted during the construction phase, the licensee shall either control these activities under this Operational Quality Assurance Program or under an NRC accepted Construction Quality Assurance Program (Per 0QAM 3.5.18).
When this Operational Quality Assurance Program is used, the licensee shall comply with the Regulatory Positinn established in this Regulatory Guide in that Quality Assurance programmatic / administrative requirements included therein shall apply to these maintenance and modification activities even though such requirements may not have been in effect originally.
Technical requirements associated with maintenance and modifications shall be Page 26 of 37 Appendix A Rev. 11 0QAMRll.B/SQPFLR
NRC Regulatory Guide 1.94 - Section 1 (Continued):
the original requirements or better (e.g., code requirements, material properties, design margins, manuf acturing processes and inspection requirements).
?)
With regard to Section 1.2 of ANSI N45 " 5 - 1974 titled Applic ab_ilit_y: 1he first sentence in this Section is not a)plicable to the operations phase.
The licensee shall comply with t1e third sentence in this Section with the clarifications that "importance of the item or service involved" is interpreted to mean those to which the Operational Quality Assurance Manual applies, and the extent of coverage shall be defined,y supervisory maintenance personnel by the way ir which they implement the other requirements of this Standard, in the second paragraph of this Section, the licensee shall substi-tute the words " maintenance and modification" for the word "construc-tion" as the modifier of " procedures".
3)
With regard to Section 1.3 of ANSI N45.2.5 - 1974 titled Responsibilijt :
This Section s requirements are met by the definitions for positions and the organizational responsibilities outlined in the Technical Specifications, Policy 1 of the 0QAM and the position descriptions for plant personnel.
4)
With regard to Section 1.4 of ANSI N45.2.5 - 1973 titled Def;nitions:
Definitions in this Standard wh 'h are not included in ANSI N45.2.10 shall be used: All definitions which are included in ANSI N45.2.10 shall be used as clarified in the licensee's commitment to Regulatory Guide 1.74.
5)
With regard to Section 2:1 of ANSI N45.2.5 - 1974 titled Planning:
Plenning requirements, when necessary, shall be incorporated into maintenance and modification procedures.
6)
With regard to Section 2.5.2 of ANSI N45.2.S - 1974 titled Calibration and Control:
The last sentence of this section requires that all items inspected with M&TE which is found to be out of cali-bration shall be considered unacceptable.
The licensee will comply with an alternate which will require evaluation to determine the va-lidity of previous measurements.
This alternative is consistent with ANSI N45.2.4, Section 2.5.2; ANSI N45.2.1, Section 2.5.2; ANSI N45.2.8, Section 2.8.2; ANSI N45.2.13, Section 7.4.2, and ANSI N18.7, Section 5.2.16.
7)
With regard to Section 5.5 of ANSI N45.2.5 - 1974 titled Wclding: The licensee will comply with inspection requirements of the applicable welding codes identified in the UFSAR and any exceptions thereto.
" Quality Assurance Requirements for Installation, inspection and~ testing o FMechanical Equipment and Systems" (Rev 0-R, 6/76)
Endorres ANSI N45.2.8 - 1975.
OQAMR11.B/SQPFLR
I NRC Regulatory Guide 1.116 (Continued):
The Operational Quality Assurance Program complies with the requirements of this Guide with the following clarifications:
1) for operations phase maintenance and modification activities which are comparoole in nature and extent to similar activities conducted during the construction phase, the licensee shall either control these activities under this Operational Quality Assurance Program or under an NRC accepted Construction Quality Assurance Program (Per OQAM 3.5.18). When this Operational Quality Assurance Program is used, the licensee shall comply with the Regulatory Position established in this Regulatory Guide in tiiatWTity Assurance i
programmatic / administrative requirements included therein shall h
apply to these maintenance and modification activities 'ven though such requirements may not have been in effect originally.
Technical requirements associated with maintenance and modificaticos shall be the original requirements or better (e.g., code requirements, material properties, design margins, manufacturing processes, and j
inspection requirements).
2)
With regard to Section 1.1 of ANSI N45.2.8 - 1975 titled Scope:
The last paragraph of this Section is not applicable to the operaiions phase.
The applicable portions of the requirements of this Standard shall also be applied after fuel load; therefore, the last twenty-two words in the last sentence of the second paragraph under this Section are also not appropriate to the operations phase.
3)
With regard to Section 1.2 of ANSI N45.2.8 - 1975 titled Applicability:
The first sentence in this Section is not applicable l
to tfie operations phase.
The licensee shall comply with the third sentence in this Section with the clarifications that "important me-chanical systems to be, covered" is interpreted to mean those to which the OQAM applies, and the extent of coverage" shall be defined by supervisory maintenance personnel by the way in which they implement the other requirements of this Standard.
4)
With regard to section 1:3 of ANSI N45.2.8 - 1975 titled Responsibil-i ty~ :
This Section's requirements are met by the definitions for po-sitions and the organizational responsibilities outlined in the Tech-nical Specifications, Policy 1 of the 0QAM and the position descrip~
tions for plant personnel.
5)
With regard to Section 1.4 of ANSI N45.2.8 - 1975 titled Definitions:
Definitions in this Standard which are not included in AN T N45.2] O
~
shall be used:
All definitions which are included in ANSI N45.2.10 shall be used as clarified in the licensee's commitment to Regulatory Guide 1.74.
6)
With regard to Section 2.1 of ANSI N;5.2.8 - 1975 titled Planning:
Planning requirements, when necessary, shall be incorporated into maintenance and modification procedures.
l 00AMRll.8/SQPFLR
c s
" Quality Assurance Requirements for Control of g
[
Procurement-of-Items-and Services for Nuclear Power Plants" (Rev.-1, 7/77) En-J
'dorses ANSI N45.2.13 - 1976.
The Operational Quality Assurance Progran complies with the requirements of this Guide with the following clarifications:
1)
With-regard to Section 1.3 of ANSI N45.2.13 - 1976 titled Definitions: With two exceptions (Procurement Document and Quality Assurance Program Requirements) definitions in this Standard which are not included in ANSI N45.2.10 will be used; all definitions which are included in ANSI N45.2.10 will be used as clarified in the licensee's commitment to Rep.ulatory Guide 1.74.
The two exceptions are defined in Appendix A u9 der Regulatory Guide 1.74.
2)
With regard to Section 1.2.2 of ANSI N45.2.13 - 1976 titled Purchaser's ' Responsibiliti_es t item c is one of the options which may be used by the licensee to assure quality; however, any of the op-tions given in 10CFR50, Appendix B, Criterion vil as implemented by Policies 4 and 7 of the Operational Quality Assurance Program may also be used.
3)
With regard to Section 3.1 of ANSI N45.2.13 - 1976 titled Procurement Document Preparation, Review and Change Control: The phrase "the same degreif of control" is stipulated to mean " equivalent level of review and approval." The changed document may not always be rereviewed by the. originator; however, at least an equivalent level of management / supervision shall review and approve any changes.
4)-
With regard to Section 3.4 of ANSI N45.2.13 - 1976 titled Procurement Document Control:
The licensee will meet the requirements of Poli-
- ies 4 and 7 of-the Operational Quality Assurance Program in lieu of the renC rements specified in this Section.
5)
With r gard to Section 5.3 of ANSI N45.2.13 - 1976 titled Preaward Evaluation:
The licensee will comply with an alternate paragraph Rich reads: "Except in unusual circumstances (e.g., replacement
-. parts are needed to preclude the development of some unsafe condition at a nuclear facility), a preaward evaluation of the Supplier shall be perforraed as required by the Operational Quality Assurance Pro-
~
gram."
6).
With regard to Section-6.4 of ANSI-N45.2.13 - 1976 titled Control of Changes in Items or Services: The phrase _"the Operational Quality Assuranci Program" wiTi be inserted in lieu of " ANSI N45.2, Section 7."
Page 29 of 37 Appendix A Rev. 11 1
NRC Regulatory Guide 1.123 (Continued):
7)
With reqard to Section 8.2 of ANSI N45.2.13 - 1976, titled Dispositig:
The third sentence of item b is revised to read:
"Nonconformances to the contractual procurement requirements or Purchasc' approved documents which consist of one or more of the following shall be submitted to the Purchaser for approval of the recommended disposition prior to shipment when the noncon--
formance could adversely affect the end use of a a.w ule or shipable component # relative to safety, interchangeability, operability, reliability, integrity, or maintainability:
1)
Technical or materiti requirement is violated; 2)
Requirement '
- m. plier documents, which have been approved
,s violated; by the Purch4 a
3)
Nonunformance cannot be corrected by continuation of the original manuf acturing process or by rework; and/or 4)
The item does not conform 'a the original requirement even though the item can be renored to a condition such that the capability of the item to function is unimpaired."
- A module is an assembled device, instrument, or piece of equipment identified by serial number or other identification code, having been evaluated by inspection and/or test for conformance to procurement requirements regarding end use. A shippable component is a part or subassembly of a device, instrument, or piece of equipment which is shipped as an individual item and which has been evaluated by inspec-tion and/or test for conformance to procurement requirements regard-ing end use.
8)
With regard to Section 12 of ANSI N45.2.13 - 1976 titled Audit of Procurement Program:
The licensee audit program will be implemented in accordance with and to meet the requirements of: ANSI N45.2.12 as endorsed in Appendix A; Policies 2, 4 and 18 o,
'he Operational Qeal-ity Assurance Program, and the requirements of the individual nuclear facility Tect.nical Specifications.
9)
Paragraph C.S.e of Regulatory Guide 1.123 (and Section 10.3.4 of ANSI N45.2.13 which it references), shall be implemented as originally').
written (i.e., with the verb "should" instead of the verb "shall This flexibility is necessary because the licensee may not always be able to obtain agreement with a Supplier.
The licensee retains the ultimate responsibility for performance of purchased equipment.
The appropriate engineering discipline will exercise this manage-ment / engineering prerogative with respect to the final decision on post installation test requirements.
- 10) With regard to Section II of ANSI N45.2.13 - 1976 titled Quality Assurance Records:
The licensee shall maintain records in accordance with and to meet the requirement, of Policy 17 of the 0QAM and ANSI N45.2.9 as specified in Appendix A.
Page 30 of 37 Appendix A Rev. 11 0QAMR11.B/SQPFLR
=
" Auditing of Quality Assurance Programs for Nucle-ar Power _ Plants" (Rev. 1,_9/80) - Endorses ANSI N45.2.12 - 1977.
The Operational Quality Assurance Program compiles with the requirements of this Guide with the following c'arifications:
~
1)_
With regard to Section 1.4 of ANSI N45.2.12 - 1977 titled Definitions: With two exceptions (Program Deficiencies and audits) the definitions in-this Standard which are not included in ANSI N45.2.10 will be used:
All definitions which are. included in ANSI N45.2.10 will be used as clarified in the licensee's commitment to Regulatory Guide 1.74.
The excepted definitions are defined in Appendix-A under Regulatory Guide 1.74.
2)
With' regard to Section 2.2 of ANSI N45.2.12 - 1977 titled Personnel Qualification: The qualification of licensee audit personnel will be accomplished as described to meet the requirements of ANSI N45.2.23 1978 as endorsed in Appendix A and Pnlicies 2 and 18 of the Opera-tional Quality Assurance Program.
3)
With regard to Section 2.3 (and subsections 2.3.1 through 2.3.3) of-ANSI N45.2.12 - 1977 titled Training:
The training of licensee audit personnel will'be accomplished as described to meet the requirements of ANSI N45.2.23 - 1978 as endorsed in Appendix A and Policies 2 and 18 of.the Operational Quality Assurance Program.
4)
With regard to Section 2.4 of ANSI N45.2.12 - 1977 titled Maintenance of Proficiency: The maintenance of proficiency of licensee audit personnel will be accomplished as described to meet the requirements of ANSI.N45.2.23 1978 as endorsed in Appendix A and Policies 2 and 18 of the Operational Quality Assurance Program.
5)
With regard to Section 3.3 of ANSI N45.2.12 - 1977 titled Essential Elements _of'the Audit System: The licensee will comply with subsec-tion 3.3.5 as it was originally' written (subsection 3.2.5) in ANSI
'N45.2.12, Draft'3, Revision 4:
" Provisions for reporting on the ef-
'fectiveness of the quality assurance program to the responsible man-agement." For the auditing organization (licensee), effectiveness is
-reported as required by the individual nuclear facility Technical Specifications and paragraphs (currently. numbered 1.3.1, 1.3.2 and 1.3.15) in Policy 1 of the Operational Quality Assurance Program.
Other than audit reports, the licensee may not directly report on the L
effectiveness of the quality assurance programs to the audited organ-ization when such organizations are outside of the licensee.
l Subsection 3.3.6 requirements are considered to be fulfilled by com-l pliance with the organization and reporting measures outlined in the Operational Quality Assurance Program.
Page-31 of 37 Appendix A Rev. 11 L
0QAMR11.B/SQPFLR
i NRC Regulatory Guide 1.144 (Continued):
Subsection 3.3.7requiresverificationofeffectivecorrectiveaction on a " timely basis.'
Timely basis is interpreted to mean within the framework or period of time for completion of corrective action that is accepted by the organization.
Each finding requires a response and a corrective action completion date; these dates are subject to revision (with the approval of Quality 'rograms or Supplier Quality Assurance) and must be escalated to higher authority when there is a disagrecment between the audited and the auditing organization on what constitutes " timely corrective action."
6)
With regard to Section 3.5 of ANSI N45.2.12 - 1977 titled Scheduling:
Subsection 3.5.3.1 is interpreted to mean that the licensee may pro-cedurally control qualification of a contractor's or supplier's qual-ity assurance program prior to awarding a contract or purchase order by means other than audit.
7)
With regard to Section 4.3.1 of ANSI N45.2.12 - 1977 titled Pre-Audit Conference:
The licensee will comply with the requirements of this Section by inserting the word "Normally" at the beginning of the first sentence.
This clarification is required because, in the case of certain unannounced audits or audits of a particular operation or work activity, (monitoring auait) a pre-audit conference might inter-fere with the spontaneity of the operation or activity being audited.
In other cases, persons who should be present at a pre-audit confer-ence may not always be available: such lack of availability should not be an impediment to beginning an audit.
Even in the above exam-ples, which are not intended to be all inclusive, the material set forth in Section 4.3.1 will be covered (if considered necessary or desirable as determined by the Audit Team Leader by signature on the audit report) during the course of the audit.
8)
With regard to Section 4.3.2 of ANSI N45.2.12-1977 titled Audit Process:
(a)
Subsection 4.3.2.2 could be interpreted to limit auditors to the revlew of only objective evidence; sometimes and for some pro-gram elements, no objective evidence may be available.
The licensee will comply with an alternate sentence which reads:
"When available, objective evidence shall be examined for com-pliance with quality assurance program requirements.
If subjec-tive evidence is used (e.g., personnel interviews) then the au-dit report must indicate how the evidence was obtained."
(b)
Subsection 4.3.2.4 is modified as follows to take into account the fact that some conditions adverse to quality are virtually
" obvious" with respect to the needed corrective action:
"When a condition adverse to quality is identified as a result of an audit, unless the apparent cause, extent, and corrective action are readily evident, f arther investigation shall De conducted by the. audited organization in an effort to identify the cause and effect and to determine the extent of the corrective action required."
Page 32 of 37 Appendix A Rev, 11 0QAMRll.B/SQPFLR
NRC Regulatory Guide 1.144 - Section 8 (Continued):
(c)
Subsection 4.3.2.5 contains a recommendation which is clarified with the definition of " acknowledged by a member of the audited organization"=to mean that "a member" of the audited organiza-tion has been informed of the findings; it does not mean that that person agrees with the findings. Agreement or disagreement with a finding may be-expressed in the response from the audited organization.
(d)
Subsection 4.3.2.7 is not considered applicable as written. The licensee will comply with an alternate sentence which reads:
" Corrective action taken as a result of the last previous audit of the same area shall be reviewed or reaudited, if necessary, to evaluate the effectiveness of the action to resolve the iden-tified condition adverse to quality."
9)
.With regard to Section 4.3.3 of ANSI N45.2.12 - 1977 titled Post-Audit Conference:
The licensee will substitute and comply with the following paragraph:
"For all external audits, a post-audit con-ference shall be held with management of the audited organization to present audit findings and clarify misunderstandings; where no ad-verse findings exist, this conference may be waived by management of the-audited organization: such waiver snail be documented in the audit report. Unless. unusual operating or maintenance conditions pre-clude attendance by appropriate managers / supervisors, a post-audit conference shall be held with managers / supervisors for all internal audits for the same reasons as above. Again, if there are no adverse findings, management of the internal audited organization may waive the post-audit conference:
such waiver shall be documented in the audit report."
- 10) With regard to Cection 4.4 of ANSI N45.2.12 - 1977 titled Reporting:
(_a) This Section requires that the audit report shall be tigned by the audit team leader; th s is not always the most expeditious i
route to take to assure that the audit report is issued as soon as practical.
The licensee will comply with Section 4.4 as clarified in the following opening:
"An audit report, which shall be signed by the audit team leader, or his supervisor _in-his~ absence, shall provide:" In cases where the audit report is not signed by the Lead Auditor due to his absence, one record copy of the report must be signed by the Lead Auditor upon his return.
The report shall not require the Lead Auditor's re-view / concurrence / signature if the Lead Auditor is no longer employed by the licensee at the time the audit report is issued.
(b) The licensee will comply with subsection 4.4.3 clarified to read: " Supervisory level personnel with whom significant discus-sions were held during the course of pre-audit (where conduct-ed), audit, and post-audit (where conducted) activities."
l-I Page 33 of 37 Appendix A Rev. 11 L
0QAMR11.B/SQPFLR-
^
-NRC' Regulatory Guide 1.144 - Section 10 (Continued):
(c) Audit reports may not necessarily contain~an evaluation state-ment regarding the effectiveness of the quality assurance pro-i gram elements which were audited, as required by subsection 4.4.4, but they will provide a summary of the audited areas and the results.
-(d) Subsection 4.4.6 requires audit reports to include recommenda-tions for corrective actions; the licensee may choose r;ot to comply with this requirement.- Instead, licensee auditors / lead auditors are required to document all adverse audit findings.
The procedure for processing quality deficiency documents allows.
the auditor / lead auditor to document actions which are consid-ered necessary to correct the finding, the auditor / lead auditor
-may also_ document actions which are considered unacceptable for correcting the: finding: the quality deficiency'ducument with these " Auditor Recommendations" is then transmitted to the au-dited organization.
In addition, appropriate Quality Programs, Services Quality assurance, or Supplier Quality Assurance per-sonnel are required _to review corrective action taken for the condition adverse to quality document and determine if it is acceptable. Any disagreements must be escalated to higher man-agement-for resolution.
(e) The last paragraph in Section 4.4 deals with distribution of audit reports.
The licensee will comply with these requirements after substituting the following for the last sentence:
"The audit report shall be. issued within thirty working days after the last day of the audit."
- 11) With regard to Section 4.5.1 of ANSI N45.2.12 - 1977-titled By Audited Organization:
The licensee will comply with the following clarification of this Section:
" Management of the audited organiza-tion or activity _shall review and investigate all adverse audit find-ings, as necessary, to determine and schedule appropriate corrective action including action to prevent 1ecurrence - They shall respond,
-in writing, within thirty working days after the date of issuance of quality deficiency documents generated as a result of the audit clearly stating the corre::tive action taken or planned to prevent recurrence and the results of the investigation if conducted.
Howev-er, written response is not necessary'if corrective action is taken and verified prior to issuance of the' audit report._=The audited or-ganization shall take appropriate action to assure that corrective action is accomplished as scheduled." The Director, Quality or the 13 i
Manager, Quality, as applicable, may, at their discr:
on, waive the requirement for a supplementary response.
i l
p u
Page 34 of 37 Appendix A Rev. 11 0QAMR11,B/SQPFLR
0 N'RC Regulatory Guide 1.144 (Continued):
- 12) 'With regard to Sections 3.4 and 4.2.1 of ANSI N45.2.12 - 1977 titled Audit PI' ninc.and Written Plan respectively:
In the case of a
-monitoring aucit provisions Tor " Written' Plan" is met by the overall audit: planning documents, which may include the audit plan.
The audit plan is encompassed by the individual audit report (although may not be identified uniquely as audit plan).
In t1e case of monitoring audits the written plan may appear in a different form.
- 13) Paragraph C.3.a of Regulatory Guide 1.144 (and Section 3.5.2 of. ANSI l
N45.2.12 which it references) shall be implemented by meeting the audit requirements of the GGNS Technical Specifications for audits underC.3.a(1).
Audits under C.3.a(2) are not covered by this 0QAM.
14)
Paragraph C.3.b(2) first sentence is replaced with the following:
Each Supplier is evaluated initially to determine the acceptability of his quality assurance program.
If acceptable, the Supplier is placed on the Qualified Supplier List. Audits, when used as the se-lected method of source verification, should be conducted as follows:
Paragraph C.3.b(2), second paragraph is replaced with the following:
An evaluation of the supplier should be performed annually.
This evaluation must be foc.nal, with the results documented and approved
-by responsible-Supplier Quality Assurance management; and it-must consider pertinent' factors such as the results of other audits, his-tory cf performance of product and/or purchased service, and effec-tive w s of implementation of the Supplier's Quality Assurance pro-gram. This annual evaluation shall consider the complexity of the component concerned and the degree of quality and process control required by the manufacturing effort._ As a result of the evaluation, Suppliers requiring a formal reaudit are identified.
Regardless of the results of the evaluation, Suppliers shall be re-audited every three years.
Paragraph additions to C.3.b(2) are as follows:
Previously evaluated and approved active suppliers, for which audit is not the selected method of source verification, should be evaluated concu rent with the award of a contract.
Regardless of the results of tne evalua-tion, active Suppliers (except those excluded under C.3.b(1) above) shall have been_ source verified (audit, surveillance or inspection) within two years prior to award of a contract or have source verifi-cation performed.
Inactive Suppliers shall be evaluated prior to supplying safety-related items or services. An audit shall be conducted IF required
~
to determine the acceptability of procured items or services (i.e.
acceptability cannot be determined Dy receipt inspection or one of the other methods allowable under 10CFR50, Appendix B, Criterion VII).
Paragraph addition to C 5 as follows:
When another purchaser's audit is used without being designated "on behalf" of more than one 13 purchaser, a copy of the results of the audit is obtained and reviewed for acceptability.
L Page 35 of 37 Appendix A Rev. 11 0QAMR11.8/SQPFLR l
NRC Regulatory Guide 1.144 (Continued):
- 15) Paragraph C.4.a of Regulatory Guide 1.144 (and Section 3.5.3.3 of ANSI N45.2.12 which it references) shall be implemented with the clarification that the Director, Quality, the Manager, Quality or 11 their designee shall determine which reorganizations or procedure revisions are "significant."
- 16) With regard to Section 5.1 of ANSI N45.2.12 - 1977 titled General:
The licensee shall maintain records in accordance with and to meet the requirements of Policy 17.0 of the 0QAM and ANSI N45.2.9 as spec-ified in Appendix A.
- 17) With regard to Section 4.3.2 of ANSI N45.2.12 - 1977 titled Audit Process:
Subsection 4.3.2.6 is modified as follows to account for the fact that immediate notification is not always possible: "Condi-tions requiring immediate corrective action (i.e., those which are so severe that any delay would be undesirable) shall be reported to man-agement of the audited organization. Where responsible management personnel are available (such as at an operating nuclear power plant), these co~litions shall be reported immediately.
If responsi-ble management personnel are not available (such as at a Supplier's shop on a back shift or for items discovered during a review of ven-dor supplied materials), these conditions shall be reported as soon practical."
" Qualification of Quality M surance Program Aud b Personnel for Nuclear Power Plants" (Rev 0, 8/80) - Endorses ANSI N45 2.23
-1978.
The Operational Quality Assurance Program complies with the requirements of this Guide with the following clarifications:
1)
With respect to Section 2.2 of ANSI N45.2.23 - 1978 titled Qualification of Auditors:
Subsection 2.2.1 references an ANSI B45.2 (presumed to be N45.2); the Operational Quality Assurance Program does not include a commitment to this standard; therefore, the licensee will comply with an alternate subsection 2.2.1 which reads:
Orientation to provide a working knowledge and understanding of the Operational Quality Assurance Program, including the ANSI standards and Regulatory Guides included in Appendix A of that Program, and the licensee's procedures for implementing audits and reporting results.
2)
With respect to Section 4.1 of ANSI N45.2.23 - 1978 titled Organizational Responsibility:
The licensee will comply with this Section with the substitution of the following sentence in place of the last sentence in the Section.
Page 36 of 37 Appendix A Rev. 11 0QAMR11.8/SQPFLR
=-.
NRCRegulatoryGuide1.146(Continued):
The Director, Quality; Manager,-Quality Systems; the Manager, Quality or Lead Auditor shall, prior to commencing the audit, assign personnel who collectively have experience or training commensurate with the scope, complexity, or special nature of 11 the activities to be audited.
Self-initiated audits will be
-p'erformed by qualifled-auditors, but no assignment is made prior to commencing-the audit" since it is self-initiated.
3)
With' r espect to Section 3.2 of ANSI N45.2.23 - 1978 titled Maintenence of Proficiency:
The licensee will comply with the re-quirements of this Section by defining " annual assessment" as one which takes place at least every twelve (12) months (to a maximum of fifteen [15])andwhichuseseithertheinitialdateofcertification or the last annual assessment date (not the calendar year) as the
-starting date for_ determining when such annual assessment is due.
4)
With respect to Section 5.3 of ANSI N45.2.23 - 1978 titled Updating of Lead Auditors' Records:
The licensee will substitute the follow-ing sentence for this Section:
1 Records for each Lead Auditor shall be maintained and updated during: the period of the annual management assessment as defined in Section 3.2 (as clarified).
5)
With respect to Section 5.4 of ANSI N15.2.23 - 1978 titled Record
-Retention:
The licensee will substitute the following sentence for this Section.
Qualification records shall be retained as required by the Oper-ational-QualityAssurance Program.
6)'
With regard to Section 2.3.1.3 of ANSI N45.2.23 - 1978 titled Other Credentials of Professional' Competence: Add "This includes R0 (maxi-mum-of 1 credit) and SR0 (maximum of 2 credits) licenses" to last sentence of this subsection.
Page_37 of 37 Appendix A Rev. 11 0QAMR11.8/SQPFLR i
' APPENDIX BL DOCUMENT CONTROL RESPONSIBILITY FOR' QUALITY-RELATED DOCUMENTS DOCUMENT PREPARED BY REVIEWED BY APPROVED BY ISSUED BY-A.
Operational-Quality Programs
-Director, Vice President,
- Director, Quality Assurance
-Quality (5)
Engineering Quality.
11 Manual (Topical)
Director, Nuclear.
Vice President, Support
' Operations GGNS
- Director, Vice President, Design Engineering Administrative GGNS Services & Regulatory Affairs General Manager, Vice President, Plant Operations Operations Support Director, Plant Projects & Support Director, Business Services -
Director, Nuclear Senior Vice President, Safety and Regulatory Planning & Assurance j.
Affairs 11 Director, Central Licensing Manager, Quality 11 Director, Materials Purchasing & Contracts Rev. 11 APPB118.RFT/SQPFLR
APPENDIX B DOCUMENT PREPARED BY REVIEWED BY APPROVED BY ISSUED BY B.1. Quality Assurance Quality Quality Director, Quality Director, Quality Procedures Programs Programs
- 2. Quality Assurance Quality Quality Responsible Manager,
- Manager, Instructions Programs Programs Quality Quality Services Programs
- 3. Supplier Quality Supplier.
Supplier Manager, Quality Manager, Quality 11 Assurance Quality Assurance Quality Assurance Director, Quality (5)
Procedures
- 4. Non-site specific Services QA Services QA Manager, Quality Manager, Quality Quality Assurance Procedures Director, Quality (5)
- 5. Services QA Services QA Services QA Manager, Quality Manager, Quality Procedures Director, Quality (5)
C.
Plant Staff and Plant Modification and' Construction Procedures 1.
This Section deleted in Revision 4
- 2. Administrative Plant Staff and General Manager, General Manager, General Manager, Procedures Plant Modification Plant Operations Plant Operations Plant Operations (Safety-Related) & Construction Manager, Plant Manager, Plant Modification &
Modification &
Construction (9)
Construction (10)
Director, Quality (5) 11 Plant Safety Review Committee (8)
- 3. This section deleted in Revision 3.
Rev. 11 Page 2 of 6 APPBilB.RFT/SQPFLR
APPENDIX B DOCUMENT PREPARED BY REVIEWED BY.
-APPROVED BY.
ISSUED BY-
- 4. Plant Section Plant: Staff and See Note (15)
See Note (15)
.See Note (15)
Procedures Plant Modification
& Construction-
' Assigned Reviewer-See Note-(3).
- 5. Plant.Section Plant Staff and.
See Note (15)
See Note (15)
See Note (15)
Instructions Plant Modification
& Construction Assignad' Reviewer
.(See Note 3)-
D.
.This section deleted in Revision 4 E.1. Entergy Responsible Director, Quality Responsible.
Administrative Operations Staff
.(14)
Vice President Services Management Manual.
Responsible Director / Manager
- 2. Nuclear Nuclear Support Section Manager Director, Nuclear Director, Nuclear Support Staff
. Support' Support' Administrative Director,-Quality i
Procedures (5)
General Manager, Plant Operations (11) i Man'ger, Director, Nuclear Director, Nuclear-
- a. Environmental Nuclear Support.
a Surveillance Staff-Environmental Support Support' Program Services Section Procedures Assigned Reviewer See Note (3) 11
- 3. Nuclear
-Nuclear Safety and Director, Nuclear Director, Nuclear-Director, Nuclear Licensing' Regulatory Affairs Safety and Regulatory Administrative Staff Affairs Safety and Regulatory.
Safety and Regulatory Affairs Affairs Procedures Director, Quality (5)
Rev. 11 APPB118.RFT/SQPFLR
1 APPENDIX B DOCUMENT PREPARED BY REVIEWED BY APPROVED BY ISSUED BY
- 4. Emergency Emergency Preparedness Assigned Eeviewer General Manager, Manager, Emergency Plant Operations (12)
Preparedness Preparedness Staff 11 Administrative Director, Quality (5)
Manager, Emergency Procedures Preparedness l
F.
Nuclear Plant Nuclear Plant Nuclear Plant
- Director, Director, Engineering Engineering Staff Engineering Design Design Administrative Principal Engineer Engineering GGNS Engineering GGNS or Senior Staff Procedures Engineer or Quality Engineer Director, Quality (5) 17 G.
Ihis section deleted in Revision 5.
l H.
Q-List Nuclear Plant
- Director, Director,
- Director, Engineering Staff Design Design Design Engineering GGNS Engineering GGNS Engineering GGNS l
Manager, Fuel Fabrication (7)
Director, Quality (5) 11 1.
Administrative Administrative Section Manager Responsible Manager, Purchasing Director Services &
Services &
l11 Regulatory Affairs Regulatory Aff airs Director, Quality (5)
Administrative Staff Procedures Rev. 11 Page 4 of 6 l
APPBilB.RFT/SQPFLR
APPENDIX B DOCUMENT PREPARED BY REVIEWED BY APPROVED BY ISSUED BY 11 J.
This section deleted in Revision 11.
K.
Central Licensing Central Licensing Director, Central Director, Central Director, Central Administrative Staff Licensing acensing Licensing Procedures Director, Quality (5) l11 L.
Maintenance Maintenance Support Director, Maintenance Director, Maintenance Director, Maintenance l
Support Staff Support Support Support Administative Procedures Director, Quality (5) l11 M.
Nuclear Engineer-Nuclear Engineering Director, Nuclear Director, Nuclear Director, Nuclear ing Analysis Analysis Engineering Analysis Engineering Analysis Engineering Analysis Administrative Staff Director, Quality (5)
Procedures Rev. 11 Page 5 of 6 APP 8118.RFT/SQPFLR i
APPENDIX B Responsible individuals listed above may have designated alternates who are authorized to perform the NOTE:
1) function.
2)
Designated support organization (other licensee organizations, contractors, consultants, etc.)
also be authorized to perform certain of the functions.
3)
See Parag aph 5.4.3 of this Manual.
4)
Sections 6.5.3, 6.5.4, 6.5.5, 6.5.6, 6.5.8, and 6.5.13 apply to this Appendix.
The Director, Quality reviews these documents to assure quality requirements are addressed and 5)
Concurrence indicated by the actual signature may be provided by any Manager QP, provides concurrence.
the Director, Quality, or designee.
6)
Review for comment not concurrence on matters relative to procurement.
7)
On matters relating to nuclear fuel and nuclear core design.
8)
As required by the Technical Specifications.
9)
For those procedures implemented by Plant Modification and Construction.
Those procedures addressing responsibilities and authorities of the Plant Modification and Construction 10)
Section are approved by both the General Manager, Plant Operations and the Manager, Plant Hodification
& Construction.
11)
Environmental Surveillance Program Administrative Procedures Only.
12)
For those procedures directly interfacing with Plant Emergency Procedures.
l 13)
SRC Procedures Only.
14)
Safety Related Only.
Plant section procedures / instructions are reviewed and approved in accordance with the guidelines as 15) stated in Technical Specification section 6.5.3.1.
Rev. 11 Page 6 of 6 APPB118.RFT/SQPFLR
APPENDIX C LOPERATIONAL QUALITY ASSURANCE Pif0 GRAM IMPLEMENTING PROCEDURES Implementing Document by Organization 10CFR50, Appendix B, Criteria Summary 12.3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18-
'A. Quality Programs
- 1. Operational QA Manual.
X X X X X X X X X X X X X X X X X X OA Manuals describe the licensee's QA Program Policies
- 2. QA Procedure Manual X X X X X X X X X X X X X X X X X X for all 10CFR50, Appendix B Criteria, and provide appro-
- 3. QA Instruction Manual X X X X X X X X X X X X X X X X X X priate' implementation i
procedures / instructions. '(QA.
Procedures are numbered by Appendix B Criteria).
B. Nuclear Safety and Regulatory Affairs 11 Nuclear Licensing X X X X X X X X X X Emphasis of Nuclear Licensing Administrative is on construction licenses Procedures and permits; safety analysis; fire protection; and, SRC support.
C. Nuclear Plant Engineering 11 NPE Administrative X X X X X X X X-X X X X Emphasis of Nuclear Plant i
Procedures Engineering is on design, independent review, evaluation and technical support.
l l
Rev. 11 Page 1 of 4 APPC118.RFT/SQPFLR
APPENDIX C OPERATIOMAL QUALITY ASSURANCE PROGRAM IMPLEFrNTING PROCEDURES l
Implementing Document l
by Organization 10CFR50, Appendix 8, Criteria Sumary l
l 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 D. Plant Staff and Plant Modification &
Construction Operations Manual
- a. Safety Related X X X X X X X X X X X X X X X X X The Operations Manual con-tains implementing procedures Administrative for all 10CFR50, Appendix B Procedures Criteria.
l E. Emergency Preparedness Emergency Preparedness X X X X X X X
X X X Emphasis of Emergency Preparedness is on Readiness Administrative for Emergency Response.
Procedures Rev. 11 Page 2 of 4 APPC118.RFT/SQPFLR g,.
i t
APPENDIX C OPERATIONAL QUALITY ASSURANCE PROGRAM IMPLEMENTING PROCEDURES l
Implementing Document i
by Organization 10CFR50, Appendix B, Criteria 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 i.8__
Summary j
j F.
Administrative Services & Pequlatory Affairs Administrative Services X X X X X X X X
X X Emphasis of Adainist.ative Services & Regulatary
& Regulatory Affairs Affairs is on procurement Administrative and administrative services.
Procedures u.
Nuclear Support Nuclear Support X X X X X X X X X Emphasis of Nuclear Support is on environmental licenses and Administrative permits.
Procedures H.
Supplier QA Supplier QA X X X X X X X
X X X X Emphasis of Supplier QA is on supplier activities.
Procedures 1.
Central Licensing Central Licensing X X X X X X X X X X Emphasis of Central Licensing is on licensing activities.
Proced"res J.
Maintenance Support Maintenance Support X X X X X X X X X Emphasis of Maintenance Support is on maintenance Procedures activities.
Rev. 11 Page 3 of 4 APPC118.RFT/SQPFLR
I I
APPENDIX C OPERATIONAL QUALITY ASSURANCE PROGRAM IMPLEMENTING PROCEDURES Implementing Document by Organization 10CFR$0, Appendix B, Criteria Summary 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 i
K.
Nuclear Engineering Analysis Nuclear Engineering X X X X X X X X X X X Emphasis of Nuclear 71 Engineering Analysis is on Analysis Procedures engineering activities.
Rev. 11 Page 4 of 4 APPC118.RFT/SQPFLR k-
...,