Category:ENVIRONMENTAL MONITORING REPORTS(&RADIOLOGICAL)-PERIODIC
MONTHYEARML20205P2471998-12-31031 December 1998 Annual Environ Operating Rept for Jan-Dec 1998. with ML20206A9141998-12-31031 December 1998 1998 Annual Radiological Environ Operating Rept. with ML20206D9671998-12-31031 December 1998 1999 Annual Radioactive Effluent Release Rept 22,for Reporting Period,Jan-Dec 1998 ML20217M6771997-12-31031 December 1997 Annual Effluent Release Rept for 970101-1231, for Wolf Creek Generating Station ML20217K4381997-12-31031 December 1997 Annual Radiological Environ Operating Rept for 1997. W/ ML20249A2991997-12-31031 December 1997 Corrected Pages to 1998 WCGS Annual Radioactive Effluent Release Rept, Covering Period from 970101-1231 ML20217E9931997-12-31031 December 1997 Annual Environ Operating Rept for Jan-Dec 1997 ML20196H7421996-12-31031 December 1996 Corrected Pages 10,12 & 15 to Annual Radioactive Effluent Release Rept,960101-1231 ML20137X9761996-12-31031 December 1996 Annual Environ Operating Rept for Jan-Dec 1996 ML20140F4101996-12-31031 December 1996 1996 Annual Radiological Environ Operating Rept ML20138F3311996-12-31031 December 1996 Annual Radioactive Effluent Release Rept Number 20,for Jan-Dec 1996 ML20107L5621995-12-31031 December 1995 1995 Annual Radiological Environ Operating Rept ML20108B4591995-12-31031 December 1995 Annual Radioctive Effluent Release Rept,Rept 19 for Jan-Dec 1995 ML20107H6151995-12-31031 December 1995 Annual Environmental Operating Rept for 1995 ML20107L5481994-12-31031 December 1994 Rev to 1994 Annual Radiological Environ Operating Rept for Wolf Creek Generating Station ML20082T7061994-12-31031 December 1994 1994 Annual Radiological Environ Operating Rept ML20082S6391994-12-31031 December 1994 Annual Radioactive Effluent Release Rept 18 for Jan-Dec 1994 ML20082N5371994-12-31031 December 1994 Annual Environ Operating Rept 1994. W/ ML20096E2311994-12-31031 December 1994 Revised Page 37 of 1994 Annual Radiological Environ Operating Rept ML20092F3721993-12-31031 December 1993 Corrected Page 19 from Annual Radioactive Effluent Release Rept Covering Period from Jan-Dec 1993 ML20096E2251993-12-31031 December 1993 Revised Page 34 of 1993 Annual Radiological Environ Operating Rept ML20029D1131993-12-31031 December 1993 1993 Annual Radiological Environ Operating Rept. W/940428 Ltr ML20065A3291993-12-31031 December 1993 Annual Radioactive Effluent Release Rept for Jan-Dec 1993 ML20082T7131993-12-31031 December 1993 Corrected 1993 Annual Radiological Environ Operating Rept Wolf Creek Generating Station ML20082T7391992-12-31031 December 1992 Corrected 1992 Annual Radiological Environ Operating Rept Wolf Creek Nuclear Generating Station ML20096E2181992-12-31031 December 1992 Revised Page 34 of 1992 Annual Radiological Environ Operating Rept ML20126G0281992-06-30030 June 1992 Replacement Pages to Semiannual Radiological Effluent Release Rept,First Half 1992 ML20114C3781992-06-30030 June 1992 Semiannual Radioactive Effluent Release Rept 15 for Jan-June 1992 ML20095K6331991-12-31031 December 1991 1991 Annual Radiological Environ Operating Rept ML20082T7441991-12-31031 December 1991 Corrected 1991 Annual Radiological Environ Operating Rept Wolf Creek Generating Station ML20090A8991991-12-31031 December 1991 Semiannual Radioactive Effluent Release Rept 14 for Jul Through Dec 1991 ML20095J9211991-12-31031 December 1991 Annual Environ Operating Rept 1991 ML20138D3821991-12-31031 December 1991 Revised Pages to 1991 Annual Radiological Environ Operating Rept for Wolf Creek Generating Station ML20099J8041991-12-31031 December 1991 Revised Page 9 of 51 of 1991 Annual Radiological Environ Operating Rept for Wolf Creek Generating Station ML20101Q9111991-12-31031 December 1991 Revised Exposure Monitoring Data for Annual Operating Rept for 1991 ML20085C2041991-06-30030 June 1991 Semiannual Radioactive Effluent Release Rept 13,Jan-June 1991 ML20070E2181990-12-31031 December 1990 Number of Personnel & Mrem by Work & Job Function Rept, 1990 ML20082T7531990-12-31031 December 1990 Corrected 1990 Annual Radiological Environ Operating Rept Wolf Creek Generating Station ML20029B1121990-12-31031 December 1990 Semiannual Radioactive Effluent Release Rept 12,Jul-Dec 1990. W/910301 Ltr ML20076N2781990-12-31031 December 1990 1990 Annual Radiological Environ Operating Rept ML20073H8381990-12-31031 December 1990 Annual Environ Operating Rept,1990 ML20101Q9181990-12-31031 December 1990 Revised Exposure Monitoring Data for Annual Operating Rept for 1990 ML20059D2461990-06-30030 June 1990 Semiannual Radioactive Effluent Release Rept for Jan-June 1990 ML20012A2341989-12-31031 December 1989 Semiannual Radioactive Effluent Release Rept 10 for Jul-Dec 1989. ML20101Q9281989-12-31031 December 1989 Revised Exposure Monitoring Data for Annual Operating Rept for 1989 ML20042E9921989-12-31031 December 1989 Operating Corp Wolf Creek Generating Station 1989 Annual Radiological Environ Operating Rept. W/900430 Ltr ML20042E9851989-12-31031 December 1989 Annual Environ Operating Rept for 1989. W/900501 Ltr ML20245L2591989-06-30030 June 1989 Semiannual Radioactive Effluent Release Rept 9 for Period Jan-June 1989 ML20245L2731988-12-31031 December 1988 Annual Environ Operating Rept,1988 ML20101Q9341988-12-31031 December 1988 Revised Exposure Monitoring Data for Annual Operating Rept for 1988 1998-12-31
[Table view] Category:TEXT-ENVIRONMENTAL REPORTS
MONTHYEARML20206D9671998-12-31031 December 1998 1999 Annual Radioactive Effluent Release Rept 22,for Reporting Period,Jan-Dec 1998 ML20205P2471998-12-31031 December 1998 Annual Environ Operating Rept for Jan-Dec 1998. with ML20206A9141998-12-31031 December 1998 1998 Annual Radiological Environ Operating Rept. with ML20217E9931997-12-31031 December 1997 Annual Environ Operating Rept for Jan-Dec 1997 ML20249A2991997-12-31031 December 1997 Corrected Pages to 1998 WCGS Annual Radioactive Effluent Release Rept, Covering Period from 970101-1231 ML20217M6771997-12-31031 December 1997 Annual Effluent Release Rept for 970101-1231, for Wolf Creek Generating Station ML20217K4381997-12-31031 December 1997 Annual Radiological Environ Operating Rept for 1997. W/ ML20198J4961997-09-19019 September 1997 NPDES Permit KS-0079057,issued to Wolf Creek Nuclear Operating Corp ML20196H7421996-12-31031 December 1996 Corrected Pages 10,12 & 15 to Annual Radioactive Effluent Release Rept,960101-1231 ML20138F3311996-12-31031 December 1996 Annual Radioactive Effluent Release Rept Number 20,for Jan-Dec 1996 ML20140F4101996-12-31031 December 1996 1996 Annual Radiological Environ Operating Rept ML20137X9761996-12-31031 December 1996 Annual Environ Operating Rept for Jan-Dec 1996 ML20108B4591995-12-31031 December 1995 Annual Radioctive Effluent Release Rept,Rept 19 for Jan-Dec 1995 ML20107L5621995-12-31031 December 1995 1995 Annual Radiological Environ Operating Rept ML20107H6151995-12-31031 December 1995 Annual Environmental Operating Rept for 1995 ML20096E2311994-12-31031 December 1994 Revised Page 37 of 1994 Annual Radiological Environ Operating Rept ML20082S6391994-12-31031 December 1994 Annual Radioactive Effluent Release Rept 18 for Jan-Dec 1994 ML20107L5481994-12-31031 December 1994 Rev to 1994 Annual Radiological Environ Operating Rept for Wolf Creek Generating Station ML20082N5371994-12-31031 December 1994 Annual Environ Operating Rept 1994. W/ ML20082T7061994-12-31031 December 1994 1994 Annual Radiological Environ Operating Rept ML20082T7131993-12-31031 December 1993 Corrected 1993 Annual Radiological Environ Operating Rept Wolf Creek Generating Station ML20092F3721993-12-31031 December 1993 Corrected Page 19 from Annual Radioactive Effluent Release Rept Covering Period from Jan-Dec 1993 ML20096E2251993-12-31031 December 1993 Revised Page 34 of 1993 Annual Radiological Environ Operating Rept ML20029D1131993-12-31031 December 1993 1993 Annual Radiological Environ Operating Rept. W/940428 Ltr ML20065A3291993-12-31031 December 1993 Annual Radioactive Effluent Release Rept for Jan-Dec 1993 ML20082T7391992-12-31031 December 1992 Corrected 1992 Annual Radiological Environ Operating Rept Wolf Creek Nuclear Generating Station ML20096E2181992-12-31031 December 1992 Revised Page 34 of 1992 Annual Radiological Environ Operating Rept ML20114C3781992-06-30030 June 1992 Semiannual Radioactive Effluent Release Rept 15 for Jan-June 1992 ML20126G0281992-06-30030 June 1992 Replacement Pages to Semiannual Radiological Effluent Release Rept,First Half 1992 ML20101Q9111991-12-31031 December 1991 Revised Exposure Monitoring Data for Annual Operating Rept for 1991 ML20099J8041991-12-31031 December 1991 Revised Page 9 of 51 of 1991 Annual Radiological Environ Operating Rept for Wolf Creek Generating Station ML20095K6331991-12-31031 December 1991 1991 Annual Radiological Environ Operating Rept ML20095J9211991-12-31031 December 1991 Annual Environ Operating Rept 1991 ML20138D3821991-12-31031 December 1991 Revised Pages to 1991 Annual Radiological Environ Operating Rept for Wolf Creek Generating Station ML20082T7441991-12-31031 December 1991 Corrected 1991 Annual Radiological Environ Operating Rept Wolf Creek Generating Station ML20090A8991991-12-31031 December 1991 Semiannual Radioactive Effluent Release Rept 14 for Jul Through Dec 1991 ML20085C2041991-06-30030 June 1991 Semiannual Radioactive Effluent Release Rept 13,Jan-June 1991 ML20070E2181990-12-31031 December 1990 Number of Personnel & Mrem by Work & Job Function Rept, 1990 ML20101Q9181990-12-31031 December 1990 Revised Exposure Monitoring Data for Annual Operating Rept for 1990 ML20029B1121990-12-31031 December 1990 Semiannual Radioactive Effluent Release Rept 12,Jul-Dec 1990. W/910301 Ltr ML20082T7531990-12-31031 December 1990 Corrected 1990 Annual Radiological Environ Operating Rept Wolf Creek Generating Station ML20073H8381990-12-31031 December 1990 Annual Environ Operating Rept,1990 ML20076N2781990-12-31031 December 1990 1990 Annual Radiological Environ Operating Rept ML20059D2461990-06-30030 June 1990 Semiannual Radioactive Effluent Release Rept for Jan-June 1990 ML20012A2341989-12-31031 December 1989 Semiannual Radioactive Effluent Release Rept 10 for Jul-Dec 1989. ML20101Q9281989-12-31031 December 1989 Revised Exposure Monitoring Data for Annual Operating Rept for 1989 ML20042E9851989-12-31031 December 1989 Annual Environ Operating Rept for 1989. W/900501 Ltr ML20042E9921989-12-31031 December 1989 Operating Corp Wolf Creek Generating Station 1989 Annual Radiological Environ Operating Rept. W/900430 Ltr ML20245L2591989-06-30030 June 1989 Semiannual Radioactive Effluent Release Rept 9 for Period Jan-June 1989 ML20235T4331989-02-10010 February 1989 NPDES Permit KS-0079057,issued to Wolf Creek Nuclear Operation Corp 1998-12-31
[Table view] |
Text
__ .__
i -.
i TABLE 18 1994 Land Use Census Milk and Garden Data l
1993 1994 1993 1994 D/Q DISTANCE DISTANCE DISTANCE DISTANCE (DEPOSITION (MI) / MILK (MI)/ MILK (MI) / CLOSEST (MI) / CLOSEST CONSTANT) /
SECTOR ANIMAL ANIMAL GARDEN GARDEN RANKING A none none 1.4/A1.4 2.9/A2.9-17LA1518 1.68E-09/2 l B 4.9/B4.9 none 4.2/B4.2 4.2/B4.2-18RD1758 5.30E-10/11 l C none none 2.6/C2.6 2.2/c2.2-16RD1670 6.56E-10/7 l D none none 2.1/D2.1 2.1/D2.1-QULA1571 4.32E-10/14 l E none none 1.8/E1.8 1.8/E1.8-QULA1485 7.76E-10/6 l P 4.9/F4.9 none 1.8/F1.8 1.8/F1.8-14RD1730 9.39E-10/4 l G 3.6/G3.6 none 1.6/G1.6 1.6/G1.6-QURD1384 1.55E-09/3 l H 4.9/H4.9 none 4.9/H4.9 3.1/H3.1-12RD1711 6.32E-10/8 l J none none 4.0/J4.0 3.8/J3.8-11RD1535 4.45E-10/13 l K none none 4.1/K4.1 4.1/K4.1-NARD 1120 3.30E-10/15 l L none none 2.6/L2.6 2.6/L2.6-NARD 1308 4.97E-10/12 l M none none 2.4/M2.4 2.4/M2.4-14RD1321 6.19E-10/9 .l N none none 2.6/N2.6 2.6/N2.6-HW751455 5.32E-10/10 l J i
P none none 4.3/P4.3 4.3/P4.3-16RD1112 2.61E-10/16 l Q none none 3.9/Q3.9 2.3/02.3-MTLA1619 9.36E-10/5 l R none none 2.1/R2.1 2.1/R2.1-NALA1650 1.84E-09/1 l NOTE: Underlined entries indicate changes from the 1993 Land Use Census.
1994 Jnnual Radiological Environmental Operating Report Wolf Creek Generating Station Page 37 of 54 9601220060 960116 RW 12/95 PDR ADOCK 05000482 R PDR
__-_ _--________ _ _ __ _