Attachment to WO 98-0053

'PagaIof3

- Enclosure to WO 98-0037 Pa*ge 2 of 29 Table of Contents Pa_ge Executive Summary 3

Section I 4

' Liquid Radioactive Efiluents 4

Dose Summary 8

Airborne Radioactive Effluents 10 Gaseous Effluents 12 Dose Summary 14 Section 11 16 Offsite Dose Calculation Manual Limits 16 Maximum Permissible concentrations 16 Average Energy.

17 Measurements and Approximations of Total RadioactMiy 17 Batch Releases 19 Continuous Releases 19 Doses to a Member of the Public from Activities inside the Site Boundary 19 Efiluent Concentration Limits 20 Solid Waste Shipments 21 Irradiated Fuel Shipments 22 Section ill 23 Meteorological Data 24 Validation and Changes to llistorical Meteorological Data 28 Section IV 29 Unplanned or Abnormal Releases 29 Offsite Dose Calculation Manual 29 Major Changes to Rndwaste Treatment Systems 29 Land Use Census 29 Radioactive Shipments 29 Inoperability of Efiluent Monitoring Instrumentation 29 Storage Tanks -

29 Attachment i Reprint of 1990 and 1991 Data and Revalidated Meterological Data For 1992 through 1996 l

' Attachment II OfTsite Dose Calculation Manual

,sost6o:aet 9e0610 E

PDR ADOCK N M R

N.,

I

Attachrnent to WO 98-0053

'Pzg] 2 cf 3 Ericlosure to WO 98-0037 Page 14 of 29 GASEOUS CUMULATIVE DOSE

SUMMARY

(1997)

Table 1 I

QUARTER 1 OF 1997

' ODCM CALCULATED DOSE ODCM LIMIT

% OF LIMIT TOTAL DOSE (mrem) FOR BONE 0.00E+00 7.50E+00 0.00E+00 TOTAL DOSE (mrem) FOR LIVER 8.87E -03 7.50E+00 1.18E-01 TOTAL DOSE (mrem) FOR TOTAL BODY 8.87E-03 7.50E+00 1.18E-01

'IOTAL DOSE (mrem) FOR TilYROID 8.87E-03 7.50E+00 1.18E-01

' TOTAL DOSE (mrem) FOR KIDNEY 8.87E-03 7.50E+00 1.18E-01 TOTAL DOSE (mrem) FOR LUNG 8.87E-03 7.50E+00 1.18E-01 TOTAL DOSE (mrem) FOR GI-LLI 8.87E-03 7.50E+00 1.18E-01 QUARTER 2 OF 1997 TOTAL DOSE (mrem) FOR BONE 5.14E-06 7.50E+00 6.85E-05 TOTAL DOSE (mrem) FOR LIVER 1.82E-02 7.50E+00 2.43E-01 TOTAL DOSE (mrem) FOR TOTAL BODY 1.82E-02 7.50E400 2.43E-01 TOTAL DOSE (mrem) FOR TIIYROID 1.99E-02 7.50E+00 2.66E-01 TOTAL DOSE (mrem) FOR KIDNEY 1.82E-02 7.50E400 2.43E-01 TOTAL DOSE (mrem) FOR LUNG 1.82E-02 7.50E+00 2.43E-01 TOTAL DOSE (mrem) FOR GI-LLI 1.82E-02 7.50E+00 2.43E-01 QUARTER 3 OF 1997 TOTAL DOSE (mrem) FOR BONE 3.95E-07 7.50E+00 5.27E-06 TOTAL DOSE (mrem) FOR LIVER 1.30E-02 7.50E+00 1.73E-01 TOTAL DOSE (mrem) FOR TOTAL BODY 1.30E-02 7.50E+00 1.73E-01 TOTAL DOSE (mrem) FOR TIIYROID 1.31 E-02 7.50E+00 1.75E-01 TOTAL DOSE (mrem) FOR KIDNEY 1.30E-02 7.50E+00 1.73 E-01 TOTAL DOSE (mrem) FOR LUNG 1.30E-02 7.50E+00 1.73E-01 TOTAL DOSE (mrem) FOR GI-LLI 1.30E-02 7.50E+00 1.73E-01 QUARTER 4 OF 1997 TOTAL DOSE (mrem) FOR BONE 7.02E-09 7.50E+00 9.37E-08 TOTAL DOSE (mrem) FOR I.IVER 2.00E-02 7.50E+00 2.67E-01 TOTAL DOSE (mrem) FOR TOTAL llODY 2.00E-02 7.50E+00 2.67E-01 TOTAL DOSE (mrem) FOR TilYROID 2.00E-02 7.50E+00 2.67E-01 TOTAL DOSE (mrem) FOR KIDNEY 2.00E-02 7.50E+00 2.67E-01 TOTAL DOSE (mrem) FOR LUNG 2.00E-02 7.50E+00 2.67E-01 TOTAL DOSE (mrem) FOR GI-LLI 2.00E-02 7.50E+00 2.67E-01 TOTALS FOR 1997 TOTAL DOSE (mrem) FOR BONE 5.54E-06 1.50E+01 3.69E-05 TOTAL DOSE (mrem) FOR LIVER

&OJE-01 1.50E+0]

4.00E-01 TOTAL DOSE (mrem) FOR TOTAL BODY 6.01E-01 1.50E+01 4.00E-01 TOTAL DOSE (mrem) FOR TilYROID

&l9E-02 1.50E+01 4.13E-01 TOTAL DOSE (mrem) FOR KIDNEY 60lE-02 1.50E+01 4.01E-01 TOTAL DOSE (mrem) FOR LUNG 601E-02 1.50E+01 4.00E-01 TOTAL DOSE (mrem) FOR GI-LLI

&OIE-02 1.50E+01 4.00E-01 1.11ased on Wolf Creek ODCM Section 3.2.2 which restricts dose during any calendar quarter to less than or equal to i

7.5 mrem to any organ and during any calendar year to less than or equal to 15 mrem to any organ.

i

\\

I Attachm mt to WO 98-0053 Pcge 3 sf 3 7.,,

Enclosure to WO 98-0037 Pdge 15 of 29

. GASEOUS CUMULATIVE DOSE

SUMMARY

(1997)

TABLE 2 Nuclides Released -

Quarter i Quarter 2

~ Quaner 3 Quarter 4 Total.

A.

l'ission and Activation Gases-l.

Total Release-(Ci) 1.29E-01 4.52E-01 1.22E+0i i44E+00 1.42E+01 l

1..

. Tota! Gamma Airdose (mrad) '

5.38E-05 1.92E-04 1.71 E-03 3.02E-04 2.26E-03 2.

3.

Gamma Airdose Limit (mrad) 5.00E+00 5.00E+00 5.00E+00 5.00E+ 00.

1.00E+0!

4.

. Percent of Gamma Airdose Limit 1.08E-03 3.84E-03 3.42E-02 6.04E-03 2.26E-02.

Total Heta Airdose(mrad) 2.42E-05 7.82E 05 1.88E-03 1.75E-04 2.16E-03 6.'

lieta Airdose Limit (mrad) 1.00E401 1.00E+01 1.00E+01 1.00E+01 2.00E+01 l

7.

Percent of Beta Altdose Limit (mrad) 2.42E-04 7.82E-04 1.88E-02 l.75E-03 1.08E-02 i

f II.

Particulate L

Total Particulate (Cl) -

0.00E+00 0.00E+00 0.00E+00 1.27E-08 1.27E-08 2.

. Maximum Organ Dose (mrem) 0.00E+00 0.00E+00 '

O.00E+00 1.08E-08 1.08E-08 3.

Organ Dose Limit (mrem) 7.50E+00 7.50E+00 7.50E+00 7.50E+00 1.50E401 4.

Percent of Limit 0.00E+00 0.00E+00 0.00E+00 1.44E-07 7.18E-08 C.

Tritium 1..

Total Release (Ci) 1.25E401 2.58E+01 ll83E+01 2.83E401 8.50E+0i

2. -

Maximum Organ Dose (mrem) 8.94E-03 1.83E 02 1.32E-02 1.97E-02 6.01E-02

. 3.

Organ Dose Limit (mrem) 7.50E+00 7.50E400 7.50E400 7.50E+00 1.50E+0i 4.

Percent of Limit -

1.19E-01 2.44E-01 1.76E-01 2.62E-01 4.00E-01 D.

lodine 1.

- Total 1 131,1-133 (Ci) 0.90E+00 2.95E-06 2.27E-07 1.9I E.10

- 3.1BE-06 2.

Maximum Organ Dose (mrem) 0.00E+00 '

l.83E-03 0.00E+00 1.10E-07 1.83E-03 3.

Organ Dose Limit (mrem) 7.50E+00 7.50E400 7.50E+00 7.50E+00 1.50E+01 4.

Percent of Limit 0.00E400 2.44E-02 0.00E+00 1.47E-%

1.22E-02

- This table is included to show the correlation between Curies released and the associated calculated maximum organ

- dose. The maximum organ dose is calculated using Wolf Creek ODCM methodology which assumes that an individual actually resides at the release point. ODCM Section 3.2.2 organ dose limits are used.

1