ML20092F372
| ML20092F372 | |
| Person / Time | |
|---|---|
| Site: | Wolf Creek |
| Issue date: | 12/31/1993 |
| From: | WOLF CREEK NUCLEAR OPERATING CORP. |
| To: | |
| Shared Package | |
| ML20092F371 | List: |
| References | |
| NUDOCS 9509180157 | |
| Download: ML20092F372 (1) | |
Text
r s
~ Enclosure to WO 95-00134 Page 1 of 1-
+
Corrected Enclosure to WO 94-0035 Page 19 of 31 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT (1993)
SOLID WASTE SHIPMENTS A. SOLID WASTE SillPPED OFFSITE FOR BURIAL OR DISPOSAL (Not irradiated fuel) 1.
Type of waste Unit 1-Year Est. Total Period Error %
a.
Spent resins, filter sludges, evaporator m3' 15.78E+00 bottoms, etc.
Ci 7.59E+02 2.50E+01 b.
Dry compressible waste, contaminated equip.
m3' 53.00E+00 etc.
Ci 2.61 E+00 2.50E+01 c.
Irradiated components, control rods, etc.
m3*
0.00E+00 Ci 0.00E+00 0.00E+00 d.
Other m3*
0.00E+00 Ci 0.00E+00 0.00E+00 J
m3* = cubic meters 2.
Estimate of major nuclide composition (by type of waste) a.
Spent resin, filter sludges, evaporator bottoms, etc.
Nuclide Percent Nams Abundance Curies Cs-134 37.770 2.87E+02 Cs137 33.678 2.56E+02 Ni-63 8.802 6.68E+01 Co-60 5.472
,.15E+01 C-14
.348 2.64E+00 Sr 90
.079 5.97E-01 11 3
.028 2.12E-01 Pu 241
.022 1.65E-01 Tc-99
.000 3.66E-03 Cm-242
.000 0.00E+00 1129
.000 0.00E+00 Nb-94
.000 0.00E+00 Ni-59
.000 0.00E+00 9509180157 950915 PDR ADOCK 050004B2 R _
,__PDR i