_-
[.,'-
Crystal River Unit 3, Cycle 10
~
Power.Peakine Factors E
This Limit is referred to by Technical Specfication LCO 3.2.5 Heat Flux Hot Channel Factor Fo FQ shall be limited by the following relationships:
FQ s LHRallow (Bu)/ [LHRavg
- P] (for Ps 1.0)
LHRallow(Bu) = See the following Table i
LHRavg
= 5.79 kW/ft for Mk-B9 fuel LHRavg
= 5.74 kW/ft for Mk-B4Z fuel LHRavg
= 5.79 kW/ft for Mk-B10ZL fuel P = ratio of THERMAL POWER / RATED THERMAL POWER.
Bu = Fuel Burnup (mwd /mtU)
]
Mk-B9/Mk-B10ZL LHRallow kW/ft*
Core 0
1 % 50 43333 44000 44667 57000 Elevation. ft hfwd/mtU Mwd /mtU Mwd /mtU mwd /mtU mwd /mtU mwd /mtU 2
15.5 16.0 16.0 16.0 16.0 12.6 i
4 17.5 16.5 16.5 16.5 16.3 12.6 6
17.0 16.3 16.3 16.3 16.3 12.ti 8
17.0 16.5 16.5 16.5 16.3 12.6 10 17.0 16.5 16.5 16.5 16.3 12.6 Mk-B4Z LHRallow liw/ft*
Core 0
1000 36375 38125 40312 40750 42937 60000 Elevation.
mwd /mtU mwd /mtU mwd /mtU mwd /mtU mwd /mtU mwd /mtU mwd /mtU mwd'mtU ft 2
14.5 15.5 15.5 15.5 15.5 15.5 15.5 11.6 4
16.1 16.6 16.6 16.6 16.1 16.0 15.5 11.6 6
16.1 16.1 16.1 16.1 16.1 16.0 15.5 11.6 8
17.0 17.0 17.0 16.6 16.1 16.0 15.5 11.6 10 16.0 16.0.
16.0 16.0 16.0 16.0 15.5 11.6
" Linear interpolation is used to calcolate the LHR limit to maintain the internal pin pressure below 2200 psia.
9511270210 951116 PDR ADOCK 05000302 P