ML20093E373

From kanterella
Jump to navigation Jump to search
Rev 1 to Tech Specs,Providing Addl Justification for Proposed Changes,Simplified Schematic of Piping of Seal Inventory & Details & Calculations Supporting Leak Rate Acceptance Criterion for Essential Svc Water Valves
ML20093E373
Person / Time
Site: Callaway 
Issue date: 10/03/1984
From:
UNION ELECTRIC CO.
To:
Shared Package
ML20093E364 List:
References
NUDOCS 8410120079
Download: ML20093E373 (4)


Text

e-1 CONTAINMEf1T-SYSTEMS

. SURVEILLANCE REOUIREMErlTS (Continued) hhe; accuracy of each Type A test shall be verified by a supplemental

. c.

test which:

1)

Confirms the accuracy of the test by verifying that the supple-mental test result, L minus the sum of the Type A and the superimposed leak, L,c,is equal to or less than 0.25 L,,

2)

Has a duration sufficient to establ.ish accurately the change in leakage rate between the Type A test and the supplemental test.

- and 3)

Requires that the rate at which gas,is injected into the contain-ment or bled from the containment during the supplemental test is between 0.75 L, and 1.25 L,.

d.

. Type B and C. tests'shall be conducted with gas at a pressure not

-less than P,, 48 psig, at intervals no greater than 24 months except'

-.for tests involving:

1)

Air lock's, and 2)

Purge supply and exhaust isolation valves with resilient material-seals.

xWJEAT A Air locks ~shall be te'sted and demonstrated OPERABLE by the requirements e.

of Specification 4.6.1.3; f.

Purge supply and exhaust isolation valves with resilient' material' seals shall be tested and demonstrated OPERABLE by the requirements of Specifications 4.6.1.7.2 and 4.6.1.7.4, as applicable; and g.

. The provisions of Specification 4.0.2 are not applicable.

.7,"A/J"(#7' 8 l

h0gg[o i

P CALLAWAY - UNIT 1 3/4 6-3 r

m

.. m..

m m

w REVISloNg 3/4.6' CONTAINMENT SYSTEMS BASES 3/4.6.1 PRIMARY CONTAINMENT-3/4. 6.-l.1 CONTAINMENT INTEGRITY

' Primary CONTAINMENT INTEGRITY ensures that the release of radioactive materials from the containment atmosphere will be restricted to those leakage paths and associated leak rates assumed in the safety analyses.

This restriction, in conjunction with the leakage rate limitation, will limit the SITE B0UNDARY radiation doses to within the dose guideline values of 10 CFR Part 100 during accident-conditions.

3/4.6.1.2 CONTAINMENT LEAKAGE The limitations on containment leakage rates ensure that the total containment leakage volume will not exceed the value assumed in the accident analyses at the peak accident pressure, P,.

As an added conservatism, the measured overall integrated leakage rate is further limited to les's than or equal to 0.75 L, or 0.75 L, as applicable, during' performance of the periodic t

. test to account for possible degradation of the containment le'akage barriers between leakage tests.-

The surveillance testing for measuring leakage rates are consistent with the requirements of Appendix J of 10 CFR Part 50.

.ZA/JEkr C 3/4.6.1.3 CONTAINMENT AIR LOCKS The limitations on closure and leak rate for the containment air locks are required to meet the restrictions on CONTAINMENT INTEGRITY and containment leak rate.

Surveillance testing of the air lock seals provides assurance tnat the overall air lock leakage will not become excessive due to seal damage-during-the intervals between air lock leakage tests.

i CALLAWAY - UNIT 1 8 3/4 6-1

~

]

F-SNUPPS This atmosphere into the secondary side of the steam generators.

requirement will be included in the Emergency Operating Instructions.

The test equipment to be used'during the Type C tests will con-sist' of a connection to an air supply source, a holding vessel, a a flow indicator,

t.
e pressure regulator, an sh::Inte pressure gage,

-l and associated valving.

Isolation valves will be positioned to their post-accident position by the normal method with no accompanying adjustments.

Fluid systems are properly drained and vented with the valves aligned to provide a test volume and atmospheric air back pres-

.sure on the-isolation vatsa(s) being tested.

The test volume and holding vessel are pressurized to the test pressure Pa, as specified in Chapter 16.0.

The pressure regulator (s)

The air flow rate maintain the test volume at a minimum of Pa.

into the test volume is recorded, as is the pressure reading, at the-intervals specified on the data form.

These records are utilized to determine the leakage rate ingcubic centimeters per slandard minute.

coser+ D For larger test volumes, a pressure decay method may be utilized to determine the leakage rate.

The total leakage rate for Type B and C tests must be less than 0.6 L

  • a The criteria for determining the direction in which the test i

pressure is applied to the isolation valves are as follows:

Gate Valves Test in the DBA direction.

Parallel disc a.

b.

Testing can be performed between the discs if a test connection or drain is provided in the valve design.

Test in the DBA direction.

Flexible wedge a.

b.

Testing can be performed between the wedge sections if a test connection or drain is provided in the valve design.

Test in the DBA direction.

Solid wedge a.

If the DBA flow direction is Globe Valves over the disc (flow to close),

the valve may be tested in the Rev. 6 6.2.6-6 8/81

8 INSERT A ATTACHMENT FOUR 3)

Essential service water valves EF-HV-33, 34, 45, and -46 sealed by the volume of water in the piping from these valves to, but not including, the containment coolers that they serve.

INSERT B ATTACHMENT FOUR h.

Leakage from isolation valves EF-HV-33, 34, 45, and -46 may be excluded, subject to the provisions of Appendix J,Section III.C.3, when determining the combined leakage rate provided the water volume serving the sealing function is adequate to maintain the seal-for at least 30 days.

i.

Valves EF-HV-33, 34, 45, and -46 shall be hydrostatically tested for leakage (using a water medium pressurized to 1.1 Pa) and demonstrated OPERABLE by exhibiting leak rates 3 7000 ml/hr.

INSERT C ATTACHMENT FOUR The Essential Service Water Penetrations are tested as valves which have seal water applied.

The system acts as a passive source of seal water and is consistent with the requirements of Appendix J of 10 CFR Part 50, Paragraph III.C.3.

This supply is a 30 day supply for leak rates 3 7000 ml/hr.

INSERT D ATTACHMENT FOUR The essential service water penetrations are tested as valves which have seal water applied, using a water replacement method which is.similar to the method described above.

The system acts as a passive source of seal water and is consistent with the requirements of Appendix J of 10 CFR Part 50, Paragraph III.C.3.

This supply is a 20 day supply for leak rates less than or equal to 7000 ml/hr.

l

_