O RESAR-SP/90 INTRODUCTION o
AND SITE WESTINGHOUSE ADVANCED PRESSURIZED O
WATER REACTOR O
'@ ^;""
^
\\,n*'
O O
STANDARD PLANT DESIGN
[885888Ea888lj4
i i
i l
t l
l I
l l
O 1
i i
MARCH, 1984 0467e:10/
~
~ " " " " " " "
w--_,
l l
TABLE OF CONTENTS i
Reference i
SAR Section Section Title Pace Status
1.0 INTRODUCTION
AND GENERAL DESCRIPTION OF PLANT 1.1-1 II
1.1 INTRODUCTION
1.1 -1 II 1.1.1 Plant Description 1.1 -1 1
1.1.1.1.
Scope 1.1 -1 1
1.1.1.2 Power Levels 1.1-2 I
l'.1.1. 3 Interface Information 1.1-3 1
1.1.2 Format and Content 1.1-4 1
1.1.2.1 Regulatory Guide 1.70 1.1-4 I
1.1.2.2 Standard Review Plan 1.1-4 I
1.1.2.3 Regulations and Regulatory Guidance 1.1-5 I
1.1. 3 RESAR-SP/90 Usage, Implementation, 1.1-5 I
and Backfitting
~
1.1.3.1 Usage 1.1-5 I
1.1.3.2 Implementation 1.1-6 I
1.1.3.3 Backfitting 1.1-8 I
1.1. 4 Amending RESAR-SP/90 1.1 -8 I
1.2 GENERAL PLANT DESCRIPTION
- 1. 2-1 II I
1.2.1 Site
- 1. 2-1 I
O 1.2.2 Principal Design Cri.teria 1.2-1 I
1.2.3 Plant Description 1.2-1 II 1.2.3.1 Reactor System 1.2-4 II 1.2.3.2 Reactor Coolant System 1.2-8 II 1.2.3.3 Containment Safeguards System 1.2-9 II 1.2.3.3.1 Safety Features 1.2-9 II 1.2.3.3.1.1 Emergency Core Cooling System 1.2-10 II 1.2.3.3.1.2 Containment Heat Removal System 1.2-10 II 1.2.3.3.1.3 Annulus Air Cleanup System 1.2-11 II 1.2.3.3.1.4 Hydrogen Recombiners 1.2-11 II WAPWR-I&S 11 NARCH, 1984 w w www-- e tw meer - w y--mwe**w wwww--
l I
1 TABLE OF CONTENTS (Con't) l Reference SAR l
Section Section Title Page Status 1.2.3.4 Primary Side Safeguards System 1.2-11 II j
l 1.2.3.5 Secondary Side Safeguards System 1.2-14 II i
1.2.3.6 Plant Instrumentation and Control Systems 1.2-15 II 1.2.3.6.1 Integrated Control System 1.2-15 II j
1.2.3.6.2 Integrated Protection System (IPS) 1.2-17 II l
1.2.3.7 Steam and Power Conversion 1.2-18 II 1.2.3.8 Auxiliary Systems 1.2-19 II 1.2.3.8.1 Chemical and Volume Control System (CVCS) 1.2-19 II l
1.2.3.8.2 Residual Heat Removal System (RHR) 1.2-20 II 1.2.3.8.3 Fuel / Component Storage and Handling Systems 1.2-20 II 1.2.3.8.4 Component Cooling Water System 1.2-20 II 1.2.3.8.5 Sampling Systems 1.2-21 II i
1.2.3.8.6 Emergency Diesel Generators and Support Systems 1.2-21 II 1.2.3.8.7 Plant Ventilation Sys'tems 1.2-21 II 1.2.3.8.8 Plant Fire Protection System 1.2-22 II 1.2.3.8.9 Service Water System 1.2-22 II 1.2.3.9 Facility Arrangement 1.2-23 I
1.3 COMPARISON TABLES 1.3-1 II 1.3.1 Comparisons with Similar Facility Designs 1.3-1 II 1.4 IDENTIFICATION OF AGENTS AND CONTRACTORS 1.4-1 1
1.4.1 Applicant 1.4-1 1
1.4.2 Westinghouse 1.4-1 1
1.4.3 Other Agents and Contractors 1.4-2 I
1.5 REQUIREMENTS FOR FURTHER TECHNICAL INFORMATION 1.5-1 II 1.6 MATERIAL INCORPORATED BY REFERENCE 1.6-1 II 1.7 DAAWINGS AND OTHER DETAILED INFORMATION 1.7-1 II l
1.8 CONFORMANCE WITH THE STANDARD REVIEW PLAN
- 1. 8-1 II 1.9-STANDARD DESIGNS
- 1. 9-1 1
1.9.1 Interfaces 1.9-1 I
1.9.2 Exceptions 1.9-2 I
l WAPWR-I&S iii MARCH, 1984 0467e:10/
TABLE OF CONTENTS (Con't) n Reference SAR Section Section Title Page Status 2.0 SITE CHARACTERISTICS 2.1-1 I
2.1 GEOGRAPHY AND DEMOGRAPHY
. 2.1 -1 I
2.1.1 Site Location and Description 2.1 -1 I
2.1.1.1 Specification of Location 2.1 -1 I
2.1.1.2 Site Area Map 2.1 -1 I
2.1.1.3 Boundaries for Establishing Effluent 2.1 -1 I
Release Limits 2.1.2 Exclusion Area Authority and Control 2.1-1 I
2.1.3 Population Distribution 2.1 -2 I
2.2 NEARBY INDUSTRIAL TRANSPORTATION, 2.2-1 I
AND MILITARY FACILITIES 2.3 METEOROLOGY 2.3-1 1
2.3.1 Regional Climatology 2.3-1 I
~
2.3.2 Local Meteorology 2.3-1 I
2.3.3 Onsite Meteorological Measurements Program
- 2. 3-1 1
i 2.3.4 Short-Term Diffusion Estimates 2.3-1 1
2.3.5 Long-Term Diffusion Estimates 2.3-1 I
2.4 HYDRAULIC ENGINEERING 2.4-1 I
2.5 GEOLOGY, SEISMOLOGY, AND GEOTECHNICAL
-2.5-1 I
ENGINEERING 2.5.1 Basic Geologic and Seismic Information
- 2. 5-1 1
2.5.2 Vibratory Ground Motion
- 2. 5-1 1
2.5.3 Surface Faulting 2.5-1 I
2.5.4 Stability of Subsurface Materials and 2.5-1 I
(
Foundations 2.5.5 Stability of Slopes 2.5-1 I
, 2.5.6 Embankments and Dams
- 2. 5-1 I
O WAPWR-I&S iv MARCH, 1984 0467e:10/
TABLE OF CONTENTS (Con't)
Reference SAR Section Section Title Pace Status Appendix 2A SITE CHARACTERISTICS - INTERFACES 2A-1 1
2A.2 Nearby Industrial, Transportation, and 2A-1 I
Military Facilities 2A.5 Site Interface for Geology, Seismology and 2A-2 I
Geotechnical Engineering 2A.5.1 Introduction 2A-2 I
2A.S.2 Seismic Input 2A-3 I
2A.S.3 Supporting Media for Nuclear Power Block 2A-4 I
3.0 DESIGN OF STRUCTURES, COMPONENTS, EQUIPMENT 3.1-1 II AND SYSTEMS 3.1 CONFORMANCE WITH NRC GENERAL DESIGN CRITERIA 3.1 -1 II Appendix 3A DESIGN OF STRUCTURES, COMPONENTS, EQUIPMENT, 3A-1 II AND SYSTEMS - INTERFACES 3A.3 Wind and Tornado loadings 3A-1 I
3A.3.1 Wind Loadings 3A-1 1
3A.3.2 Tornado Loadings 3A-1 I
O 4.0 REACTOR
- 4. 0-1 NA 5.0 REACTOR COOLANT SYSTEM AND CONNECTED SYSTEMS 5. 0-1 NA 6.0 ENGINEERED SAFETY FEATURES
- 6. 0-1 NA 7.0 INSTRUMENTATION AND CONTROLS 7. 0 -1 NA WAPWR-I&S y
MARCH, 1984 0467e:10/
TABLE OF CONTENTS (Con't)
Reference SAR O
Section Section Title
_P128 Status 8.0 ELECTRIC POWER
- 8. 0-1 NA 9.0 AUXILIARY SYSTEMS
- 9. 0-1 NA 4
10.0 STEAM AND POWER CONVERSION SYSTEM 10.0-1 NA 11.0 RADI0 ACTIVE WASTE MANAGEMENT 11.0-1 NA 12.0 RADIATICN PROTECTION 12.0-1 NA l
l 13.0 CONDUCT OF OPERATIONS 13.0-1 NA 14.0 INITIAL TEST PROGRAM 14.0-1 NA 15.0 ACCIDENT ANALYSES 15.0-1 NA 16.0 TECHWICAL SPECIFICATIONS 16.0-1 NA l
17.0 QUALITY ASSURANCE 17.1-1 NA 17.1 QUALITY ASSURANCE OURING DESIGN AND 17.1-1 II CONSTRUCTION 17.1.1 References 17.1-1 II O
lO HAPWR-I&S vi MARCH, 1984
TABLE OF CONTENTS (Con't)
KEY TO " REFERENCE SAR SECTION STATUS" COLUMN:
O Category I Those sections which are complete and for which no additional information is to be provided for the PDA application.
Category II Those sections which are complete insofar as providing material relevant to this system module but for which additional information will be provided in support of subsequent modules.
Category III O
Those sections for which information on interfacing systems will be provided at a later date.
!!A_
Those sections for which categorization is not applicable.
Only the section l
titles are included for clarity.
O O
O WAPWR-I&S vii MARCH, 1984 l
0467e:10/.
TABLE OF CONTENTS LIST OF TABLES Number Title Pace 1.1 -1 MAPWR NUCLEAR POWER BLOCK DEFINITION 1.1-10 1.1-2 PDA MODULE TOPICS 1.1-13
- 1. 8-1 STANDARD REVIEW PLAN DEVIATIONS 1.8-2
- 1. 9-1 INTERFACE AREAS FOR SYSTEMS, COMPONENTS-AND 1.9-3 STRUCTURES
-1.9-2 INTERFACING PROGRAMS AND ANALYSES 1.9-4 1.9-3 SITE INTERFACE PARAMETERS 1.9-5 3.1 -1 GDC APPLICABLE TO CHAPTER 2.0 3.1-2 O
l l
l l
O O
O j
WAPWR-I&S viii MARCH, 1984 0467e:10/
l TABLE OF CONTENTS LIST OF FIGURES Number Title l
- 1. 2-1 WAPWR PLOT PLAN l
1.2-2 WAPWR PLANT LAYOUT 1.2-3 FUEL ASSEMBLY OUTLINE 1.2-4 REACTOR VESSEL 1.2-5 INTEGRATED HEAD PACKAGE 1.2-6 DISPLACER ROD ORIVE MECHANISM 1.2-7 COMPARISON OF 414 AND MAPWR 1.2-8 REACTOR COOLANT SYSTEM 1.2-9 CNE OF FOUR INTEGRATED SAFEGUARDS SUBSYSTEMS NORMAL VALVE ALIGNMENT 1.2-10 INTEGRATED SAFEGUARDS SYSTEM (FOUR MECHANICAL SUBSYSTEMS) 1.2-11 GENERAL LAYOUT OF SFWS/EFWS EQUIPMENT 1.2-12 EMERGENCY FEE 0 WATER SYSTEM 1.2-13 CliEMICAL AND V0LUME C.ONTROL SYSTEM 2.1 -1 HISTOGRAM OF NEAREST SITE BOUNDARY DISTANCES FOR WESTINGHOUSE PWR SITES O
lO 1'O l
l MAPWR-I&S ix MARCH, 1984