ATTACHMENT I PROPOSED TECHNICAL SPECIFICATION CHANGE BRUNSWICK STEAM EuECTRIC PLANT 8403230054 840131 DR ADOCK 05000325 p

PDR

5.0 DESIC{(FEATURES 5.1 SITE EXCLUSION AREA s.l.1 he exclusion area shall be as shown in Figure 5.1.1-1.

I/N POPULATION ZONE The low population zone shall be as shown in Figure 5.1.2-1, based o'n 5.1.2 the informatio3 given in Section 2.2 of the FCAR.

5.2 CONTAIfMENT CONFIGURATION 5.2.1 1hs PRIMARY CONTAINMENT is a steel-lined reinforced concrete structure composed of a seria_s of vertical right cylindera and truncated cones which f ora a drywell. Mis drywell is attached to a suppression chamber chrough a series of vents. The suppression chamber is a concreta steel-lined pressure c

vessel in the shape of a torus, he primary containment has a minimum f ree air volume of (288,000) cubic feet.

DESIGN TEMPERATURE, AND PRESSURE 5.2.2 1he primary containment is designed and shall ba amintained for:

a.

Maximum internal pressure 62 psig.

b.

Maximim internal temperature:

dryuell 300 F.

suppression chamber 200 F.

i Maximpaa external pressure 2 psig.

l c.

5. 3 REACTOR COFJ!:

FUEL ASSEMBLIES The reactor core shall contain 560 fuel assemblies, with each 8 x 8 5.3.1 fuel assembly containing 63 fuel rods and each 8 x SR fuel assembly containing 62 f uel rods. All fuel rods shall be cladded with Zircaloy ' 2.

Each fuel rod shall have a nominal active fuel length of 146 inches for 8 x 8 fuel and 150 inches f or 8 x 8R fuel.

BRUNSWICK - UNIT 1 5-1 Amendment No.

DESIGN FEATURES 5.3 REACTOR CORE FUEL ASSEMBLIES (Continued)

The initial loading shall have a maximum average enrichment of 2.35 weight Reload ruel shall be Limilar in physical design to the initial percent U-235.

core loading and shall have a maximum average enrichment of 3.00 weight percent U-235.

CONTROL ROD ASSEMBLIES he reactor core shall contain 137 control rod assemblies, each 5.3.2 consisting of a cruciform array of stainless steel tubes containing 143 inches or boron carbide.,8 C, powder surrounded by a cruciform-shaped stainless steel 4

sheath.

5.4 REACTOR COOLANT SYSTEM DESIGN PRESSURE AND TEMPERATURE he nuclear boiler and reactor recirculation system is designed and i

i 5.4.1 shall be maintained:

In accordance with the code requirements specified in Section 4.2 of a.

the FSAR, with allowance for normal degradation pursuant to the applicable Surveillance Requirements.

For e pressure of 1250 peig, and

  • o.

c.

For a temperatura of 575 F.

VOLUME 5.4.2 he total water and steam volume of the reactor vesnel and recirculation system is approximately 18,670 cubic feet.

5.5 NETEOROLOGICAL TOWER LOCATION 5.5.1 he meteorological tower shall be located as t;hown in Figure 5.1.1-1.

BRUNSWICK - UNIT 1 5-4 Amendment No.