AO 50-271/72-04:on 720919,alarm Annuciated in Main Control Room,Indicating Leak in Bellows of Main Steam Relief Valve on Line D.Cause Not Stated
ML20086H355
Person / Time
Site: Vermont Yankee File:NorthStar Vermont Yankee icon.png
Issue date: 09/20/1972
From: Rosalyn Jones
VERMONT YANKEE NUCLEAR POWER CORP.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML20086H319 List:
References
AO-50-271-72-04, AO-50-271-72-4, VYV-2246, NUDOCS 8401170060
Download: ML20086H355 (1)


Text

\\"(l@fAffAMhf Hah 31761MX&310E"lciGMIlsN1ASJ1EMA9691WUPM2nMM

\\

9,_,._ n-.--, o RUTt,AND, VrmbeONT O5WM esseLv Tor WV-2246 e o. nm m VERNON. VERMONT 05354 September 20, 1972 I

United States Atomic. Energy Commistian Directorate of Regulatory Operations, Region 1 970 Droad Street Newarb New Jersey 07102 REFERENCEt Operating License DPR-28 Docket No. 50-271 Abnormal Occurrence No. A0-72-04 Centlemen:

As defined by Technical Specifications f or the Vermont Yankee Nuclear Power Station, Section 6.7.A.c we are reporting the following Abnomal Occurrence na A0-72-04 and confirming our telephone conversation with your office on this date.

On September 19, 1972, an alam annunciated in the main control.

room indicating a leak in the hellous of the main steam relief valve located on main steam Ifne D.

The failure of the bellows could render the ona relief valve incapable of automatically relieving reactor steam prenaure at its act point of 1075 paig (1080 paig +1%, Technical Specificationa Section 2.2.B).

The failed beIIn.sa in no way hinders the operation of the Automatic Depraasurization Systeta (ADS) or the reactor operatore ability to manually operate the relief valve. Although the ADS is not considered inoperable, the High Prosauro Coolant Injection Syutem was tested and demonstrated to be operabic immediately after the discovery of the fatled bellows.

Very truly yours, VBy0NT YANKEE NUCtEAR POWdR CQtPORATION OO 05hoo k PDR Robert F. J nos Plant Superintendent WPN/kbd k