public Sen" ice Company ff Odlende g

16805 WCR 19 1/2, Platteville, Colorado 80651

/

/D 1

May 7, 1984 Fort St. Vrain Unit #1 P-84135

.- m L

@ @ [9,i i ' l '. i %

Mr. John T. Collins, Regional Administrator i

r

]

j

- - ~ ~

U. S. Nuclear Regulatory Commission j

h h

611 Ryan Plaza Drive, Suite 1000 i

NM I d I Arlington, Texas 76011

{

__t s

SUBJECT:

PCRV Tendon System

~

Relaxation Curves REF:

1) P-84110, Warembourg to Collins, dated 4-12-84
2) G-84120, Collins to Lee, dated 4-19-84
3) P-84119, Warembourg to Collins, dated 4-25-84

Dear Mr. Collins:

Attached are the Fort St. Vrain PCRV tendon system relaxation curves containing the

" minimum design" lines as requested by Mr. Harold Polk.

The minimum design values for each general classification of PCRV tendons was verbally transmitted by Milt McBride to Messrs. Jim Miller, Dick Ireland, Phil Wagner and Harold Polk during a telephone conversation on May 3, 1984.

The purpose of this letter is to formally submit the information discussed in the May 3, 1984 telephone conversation.

If I can be of further assistance or if additional information regarding the tendon relaxation curves is required, please let me know.

Very truly yours, W A'ht.u v

Don W. Warembourg Manager, Nuclear Production Fort St. Vrain Nuclear Generating Station DWW/djc

/

Attachment cc:

H. L. Brey j

DR O

O O 67 2

P PDR

y o

LONGITUDINRL TENDON

( t1INI t1U t1/ t1R XI t1U t1 REL RX RT IO N )

1600 14B0 s

H INIb11.$1 -

- MRXIMUM NQ

.a 1200 7 L_ O. R__D_ ' CE_LC_ _ _._ _ '_.

_._' I

_ y

- M.

_ MIN. DESIGN _

___'_YS L

3DDD Z

O c2 z

w l-gge s

~

$0

)

a s

4 s

s r e e te is ao as tit 1E RFTER INITIRL TENSIONING (YERRS) i CROSS HE FID TENDON

( t11 N I t1U t1/ t1R X I t1U t1 REL RX RT I O N )

3ggg M IN U 1U P1- -

1400 y __._

- M R X U1 LIM h~

4 s

- r_r) 3 200

~

Q-H 5 3maa

..L_.0F_tD. CE 4..._.

w F

o

' $ B00 InfN.'D'SIGO

~'

E i

w

...I z see co a

z

- w 4DD

~

r T

200 i-

~

5

~

1 2

3 4

5 6

7 6 5 10 35 20 25 30 TIME RFTER INITIRL TENSIONING (YERRS) i v

m-

_,y-

CIRCUMFERENTIRL HERD TENDON (MINIMLIM/MRXIMLIM RELAXRTION) 1800

'1400

- - M IN 301U M

MRXIMUM rn 1220 E

H L

-E 5 stem -.L_oen.EEM._._......... A..m.4.

._.2._.._L._,_.j

-w o

ce BBD EMIN..DEBEGN

=

-7 o

.Lu

=_

z gno

.5 o

m w 4DD

~

~

t--

20e

-E 5

)

2 3

4 5

6 7 9 9 10 35 20 25 30 TIME RFTER 1NITIRL TENSIONING (YEARS)

CIRCUMFERENTIFiL HFiLL TENDON (MINIMLIM/MRX1MLIM RELRXRTION) 1600

~

14BB s

f rp

'g FM

.x MINIMUM.

-,~%~W v

3200 MAXIMUM s

.{

~

1DDD

-.L.ORD CE L L,.

N Z

T fTIIT 'UEFIGTJ - '

~---.

o

--7_%Q ca z

w

~

P-BBD D-g 3

2 3

4 5

5

? O 9 LO 35 2D 25 30 TIME AFTER INITIRL TENSIONING (YEARS)