i E.M M L
helegram' mestern uman
.vv VEB201(1719 )(1- 01442 63's )PD 11/26/ Q7dkg W requested?
dAGDR*
AGENT g ' '
j pp ADDhESSEE w ICS IPMVEI A MWi Dato did_ g yy "Tice T
- II*d By a.
C M
2C ZC 00344 CORDOVA ILL 81 11 45 tti-+0+Er Cjliver Indicate DA #UD 9Q FMS MR B GRIER REGION 3, DLR-tNL; COMPLIANCE US ATOMIC ENERGY. COMMISSION 799 ROOSEVELT RD GLEN _MYN ILL4 c/ 3 7
^
REFERENCE QUAD-CITIES NECULAT POWER STATION UNIT 1 LICEhSE DPR-29 APPENDIX A SECTION 1.0. A.2, 3 2.A AND 6 6. A.3 W HILE CONDLCTING ROUTINE SURVEILLANCE C ALIBRATION ON THE ' UNIT 1 MAIN STEAM LIhE FLok SWITC HES, TWO SWITC HES WERE FOUND TO HAVE DRIFTED BEYOND THE TEC H S PEC LIMIT.
THE SET POINT EQUIVALENT TO 120 PERCENT FLOW IS 100 PSID DPIS 1-2 61-2C TRIP AT 104 PSID DPIS 1-2 61-2 D TH1 P AT 102. PSl D.
BOTh SWI fC hES nave BEEN REC ALIBRATED s
N J KALIVI ANAKIS
/
\\
c?,
y L,~
c.
sr.im mua NOV 3 0 1972 fj' 8305180296 721201 PDR ADOCK 05000265 S