.. _ - - _ _ _ _

h I

l l

ERJ RJ Te e ram LUEStern UniDn I

t

-f

Ok VEA216(1649)(2-03264dE041)PD 02 10/),53 i

ICS IfMBhGZ UdP U.!?PiCE3 73 M..

_BY 4-

~

6159424449 TDSN MORRIS IL 69 02 h 4499etEST j - 1 l TIME.. /m./M I

c F MS J AMES G KEPPLER, RitaluNAL DIRECT &TPYOX TO EELI"C :-

DIHEC[0HIATE OF HEGULATORY OPEHATIONS-HEGION U.S. aT0filerNihdi CONMISSION 199 H00SEVELT HD

~

yLEN ELLYN IL 60167

SUBJECT:

DPH-19, uniddEN NUCLEAR POWEH STATION UNir 11.

J g fHIS WILL CONFIHM THE CONVEh6AT10N WITH clu JOHNSON OF YOUH OFFICE AT Oo' 1400 HOURS THid DATE CONCERNINd HDDITIONAL PIPE CHACK FOUNU BY oo Rg ULfRA-SONIC TEST ON Cund SPHAY LOOP A IN Ind SECTION OF PIPE DOWN n

STHEAd 0F THE MANUEL VALVE IN THE 0xfWELL. THE CHACK IS IN WELD ru:s 88 10-25 AT 12 OCLOCK HND IS APPROXIdATELY.3 INCHES LONd. THIS. WILL BE C0HHECTED WHEN OTHER CORE SPHAY PIPING IS HEPLACED LATEN IdIS MONTH.

f og B B STEPHENS SUPEHINTENDENT DRESDEN NUCLEAR POWEH STAIl0h

      • LgMON WEAg Epigog RR1 MORRIS IL 60450

.