Supplemental Final Deficiency Rept Re Bonnet Studs Improperly Torqued on DHR Valves.Initially Reported on 811222.Completion of Corrective Actions Anticipated by 840116.Also Reported Per Part 21
ML20083G772
Person / Time
Site: Bellefonte  Tennessee Valley Authority icon.png
Issue date: 12/22/1983
From: Mills L
TENNESSEE VALLEY AUTHORITY
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
REF-PT21-83 10CFR-050.55E, 10CFR-50.55E, NUDOCS 8401040339
Download: ML20083G772 (1)


Text

-_

TENNESSEE VALLEY AUTHORITY c W 6 M 38uf W e M cV F II December 22, 1983, BLRD-50-438/82-04 og DEC 29 A 9 : I 5 BLRD-50-439/82-04 U.S. Nuclear Regulatory Commission Region II Attn: Mr. James P. O'Reilly, Regional Adefnistrator 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30303

Dear Mr. O'Reilly:

BELLEFONTE NUCLEAR PLANT UNITS 1 AND 2 - BONNET STUDS IMPROPERLY TORQUED ON DECAY HEAT REMOVAL VALVES - BLRD-50-438/82-04, BLRD-50-439/82 SUPPLEMENTAL FINAL REPORT The subject deficiency was inititilly reported to NRC-0IE Inspector R. V. Crlenjak on December 22, 1981 in accordance with 10 CFR 50.55(e) as NCR 1686. This was followed by our interim reports dated January 20, April 15, June 28, August 2h, and November 1, 1982 and January 10, 1983, and our final report dated April 13, 1983 Below is our supplemental final report. We consider 10 CFR Part 21 applicable to this deficiency.

As discussed with NRC-0IE Inspector Paul Fredrickson on December 7,1983, the date of December 5,1983 for completion of corrective actions indicated in our final report on this matter was not met. The Division of Construction's priorities have been reevaluated as a result of the Bellefonte schedule reassessment program. Consequently, insufficient manpower was assigned to this task in order to complete it by the due date.

The corrective action action on this matter will be completed by January 16, 1984.

If you have any questions concerning this matter, please get in touch with l

R. H. Shell at FTS 858-2688.

Very truly yours, l

TENNESSEE VALLEY AUTHORITY 8401040339 831222 PDR ADDCK 05000438 S

PDR L. M. Mi Is, anager Nuclear Licensing cc:

Mr. Richard C. DeYoung, Director Office of Inspection and Enforcement

' U.S. Nuclear Regulatory Commission Washington,- D.C.

20555 Records Center Institute of Nuclear Pover Operations

.1100 Circle 75 Parkway, Suite 1500 OFFICIAL COPY Atlanta, Georgia 30339.

~-

1983-TVA 5OTH ANNIVERSARY f g An Equal Opportunity Employer I

._