0 INSERVICEINSPECTION REPORT UNIT 2 McGuire 1994 REFUELING OUTAGE 9 NRC Docket No. 50-370 Location: Hwy 73, Cowans Ford, North Carolina National Board No. 84 O
Commercial Service Date: March 1,1984 Owner: Duke Power Company 526 S. Church St.
Charlotte, N. C. 28201-1006 Revision 0 Prepared By:
onu 0 Mooc Date
'///o /95 Reviewed By: 4 2
vp Date e///o /95 Approved By:
Date 10 1 %
D O
Copy No.
z iesignea re nac oocumeat coatroi Controlled x
Uncontrolled "9504180296 950411 PDR ADOCK 05000370 Q
PDR t
Pages 167
'~g
/(/
FORM NIS-1 OWNERS' DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules 1.
Owner: Duke Power Comoany. 526 S. Church St. Charlotte. N. C. 28201 1006 (Name and Address of Owner) 2.
Plant: McGuire Nuclear Station. Hichway 73 Cowans Ford. N. C. 28216 (Name and Address of Plant)
- 3. Plant Unit: 2
- 4. Owner Certificate of Authorization (if required) N/A
- 5. Commercial Service Date: March 1.1984
- 6. National Board Number for Unit _E4 Component or Manufacturer or Manufacturer or State or National Appurentance Installer Installer Serial Providence No.
Board No.
No.
See paragraph 1.1 of the attached report
(~h U
Note: Supplemental sheets in form of lists, sketches, or drawings may be used provided (1) size is 8 /2 in.
1 x 11 in., (2)information in items 1 through 6 on this data report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
1 u
~
Pages 167 FORM NIS.1 (back)
- 8. Examination Dates 08/31/93 to 01/12/95 9. Inspection Interval from 03/1/94 to 03/1/2004
- 10. Abstract of Examinations. Include a list of examinations and a statement concerning status of work required for current interval. See attached renort.
- 11. Abstract of Conditions Noted. See attached renort.
- 12. Abstract of Corrective Measures Recommended and Taken. See attached reoort.
We certify that the statements made in this report are correct and the examinations and corrective measures taken conform to the rules of the ASME Code,Section XI.
Date AN 19 Signed Duke Power Co. By Owner Certificateof AuthorizationNo.(if applicable)
N/A Expiration Date N/A I
CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and/or the State or Province of N and employed by "The HSBl&I Co. of have inspected the compone is described in this Owners Data Report during the period O
toI-O and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners' Data Report in accordance with the requirements of the ASME code,Section XI.
By signing this certificate neither the Inspector nor his employer makes any warranty, exp.*essed or implied, concerning the examinations and corrective measures described in this Owners' Data.
Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this inspection.
~
Date 19 Commissions I
Inspector's Signature National Board, State, Province and No.
'The Hartford Steam Boiler Inspection & Insurance Co.
200 Ashford Center North Suite 300 Atlanta Ca.,30338 O
O CONTROIJRn DIFfRmUTION Cony No.
Assigned To Original Duke Power Company QA Technical Services 1
McGuire Mechanical Maintenance / QA Technical Support 2
NRC Document Control UNCONTROIJRn DIFPRm0 TION 3
Hartford Steam Boiler Inspection and Insurance O
Company (AIA) c/o C. A. Ireland 4
State of North Carolina Department of Labor c/o B. K. Walker O
O rim,or com-rs Section Title Revision 1.
General Information 0
2.
Summary ofInservice Inspections for Outage 9 0
3.
Second Ten Year Interval Inspection Status 0
4.
Final Inservice Inspection Plan for Outage 9 0
5.
Results ofInspections Performed During Outage 9 0
6.
Reportable Indications 0
7.
Personnel, Equipment, and Material Certifications 0
F.
Corrective Action 0
9.
Reference Documents 0
10.
Class 1 and 2 Repairs and Replacements 0
D O
1.0 General Information bm.
This report describes the Inservice Inspection of Duke Power Company's McGuire Nuclear Station Unit 2 during the 1994 Refueling Outage (also referred to as Outage 9), which is the first outage of the First Inspection Period of the Second Ten Year Interval.
Included in this report are the final Inservice Inspection Plan, the inspection results for each item, a summary for each category of examination and corrective action taken when unacceptable conditions were found.
In addition, there is a section included for repairs and replacements required since August 31,1993.
1.1 Identification Numhem Manufacturer Manufacturer State or National Item or Installer or Installer Province No.
Board Serial No.
No.
Reactor Vessel Rotterdam 30664 NC-201819 Pressurizer Westinghouse 1491 NC-201818 W10285 Steam Generator 2A Westinchouse 1481 NC-201307 68-112 Steam Generator 2B Westinghouse 1482 NC-201308 68-113 Steam Generator 2C Westinghouse 1483 NC-201309 68-114 A
Steam Generator 2D Westinghouse 1484 NC-201310 68-115 Centrifugal Pacific Pumps 2A - 485M N/A 25 Charging Pump 2B - 48585 28 Containment Spray Delta Southern Co.
2A-35005-73-3 NC.%203 3396 Heat Exchanger 2B-35005-73-4 NC-2vi822 3397 Excess Letdown Heat Westinghouse 1810 NC-234264 1555 Exchanger Letdown Heat Joseph Oat & Sons, 2049-2B,
NC-201842 553 Exchanger Inc.
Reciprocating Union Pump Co.
N721031B-604 N/A 80 Charging Pump Reactor Coolant 2A 5-114E841G02 Pump Westinghouse 2B 6-114E841G02 M/A N/A 2C 7-114E841G02 2D 8-114E841G02 Reciprocating Metal Bellows Charging Pump Company 74730-002 N/A 002 Accumulator Reciprocating Richmond Charging Pump Engineering Supply N-2409.20 N/A 75220 Suetio >. StabiLer Co.
Residual Heat Joseph Oat & Sons, 2A 2046-2C NC-169800 637 Removal Heat Inc.
2B 2N6-2D NC-201823 638 Exchanger O
Refueling Outage Report McGuire Unit 2 Page1
. Revision 0 Section 1 April 5,1995
1.1 Ident-ification Numbers (Continued)
Manufacturer Manufact urer State or National Item or Installer or Installer Province No.
Board Serial No.
No.
Regenerative Heat Joseph Oat & Sons, 628 Exchanger Inc.
2047-28 NC-201817 629 630 Safety Injection Pacific Pumps 2A 49357 N/A 130 Pump 2B 49358 131 Seal Water Heat Atlas Industrial Exchanger Manufacturing 1767 NC-201827 IM9 Company Seal Water AMF Cuno 2A - 20 N/A 4364 Injection Filter 2B - 22 4365 Main Steam Supply to Auxiliary Equipment Duke Power Co.
SA N/A W
System Containment Air Release and Addition Duke Power Co.
VQ N/A 56 System Main Steam System Duke Power Co.
SM N/A 70 Main Steam Vent to Duke Power Co.
SV N/A 67 Atmosphere System Reactor Coolant Duke Power Co.
NC N/A System Liquid Waste Duke Power Co.
WL N/A 76 Recycle System Refueling Water Duke Power Co.
FW N/A M
System Auxiliary Feedwater Duke Power Co.
CA N/A 73 System Residual Heat DL<e Power Co.
ND N/A O
Removal System Nuclear Service Duke Power Co.
RN N/A 60 Water System Chemical and Volume Control Duke Power Co.
NV N/A 80 System Component Cooling Duke Power Co.
KC N/A 78 System Main Feedwater Duke Power Co.
CF N/A 61 System O
Refueling Outage Report Page 2 McGuire Unit 2 Revision 0 Section 1 April 5,1995 l
O 1.1 1 a a a iie x e - n e - c e a e e a Manufacturer Manufacturer State or National Item or Installer or Installer Province No.
Board Serial No.
No.
Containment Spray Duke Power Co.
NS N/A s
System Containment Ventilation Cooling Duke Power Co.
RV N/A 72 Water System Safety Injection Duke Power Co.
NI N/A 8
System Unit 2 Duke Power Co.
N/A N/A
_St 1.2 Authorized Nuc1 ar inservice Insnector(s)
Name:
R. D. Klein Employer:
The Hartford Steam Boiler Inspection & Insurance q
Company v
Business The Hartford Steam Boiler Inspection & Insurance Co.
Address:
200 Ashford Center North Suite 300 Atlanta, GA 30338
?
O Refueling Outage Report Page 3 McGuire Unit 2 Revision 0 Section 1 April 5,1995
2.0 Snmmarv ofInaervice Insnections for Oufnae 9 The information shown below provides an abstract of ASME Section XI Class 1, Class 2, and Augmented Items scheduled and examined during Outage 9 at McGuire Nuclear Station Unit 2.
2.1 Class 1 Insnection Section XI Category B-A Pressum Retaining Welds in Reactor Vessel Total Total i
Item Description Scheduled Examined i
Number During Du ring Outage Outace B01.010 Shell Welds B01.011 Circumferential 0
0 B01.012 Longitudinal N/A N/A B01.020 Head Welds B01.021 Circumferential
- 1
- 1
Twickness C02.011 Nozzle to Shell (or 2
2 1
Head) Weld 1
CO2.020 Nozzles Without Reinforcing Plate in Vessels >1/2" Nominal Thickness C02.021 Nozzle to Shell (or 1
1 Head) Weld CO2.022 Nozzle Inside Radius 1
1 i
Section CO2.030 Nozzles With Reinforcing Plate in i
Vessels >1/2" Nominal Thickness CO2.031 Reinforcing Plate 0
0 Welds to Nozzle and Vessel 1
Refueling Outage Report Page 14 McGuire Unit 2 Revision 0 Section 2 April 5,1995 1
n SectionXICategory C B Pressum Retaining Nozzle Welds in Vessels V
Continued Total Total Item Description Scheduled Examined Number During During Outage Outage CO2.032 Nozzle to Shell (or Head) Welds when N/A N/A Inside of Vessel is Accessible CO2.033 Nozzle to Shell(or Head) Welds when 0
0 Inside of Vessel is Inaccessible j
TOTALS 3
3 i
(Item # C02.022) Nozzle Inside Radius Section welds are examined as i
required by table IWC-2500-1 Category C B. However, for reporting purposes, the totals do not reflect the number of Nozzle Inside Radius Section welds examined during this outage. Nozzle Inside Radius Section welds are to be examined in conjunction with CO2.021 examinations.
I A
SectionXICategory C C Intergal Attachments for Vessels, V
Piping, Pumps, and Valves Total Total j
Item Description Scheduled Examined Number During During
,i Outage Outage Pressure-Vessels C03.010 Intergally Welded 2
2 Attachments Piping C03.020 Integrally Welded 0
0 Attachments Pumps C03.030 Integrally Welded 0
0 Attachments Valves C03.040 Integrally Welded N/A N/A Attachments TOTALS 2
2
'fh a
Refueling Outage Report Page 15 McGuire Unit 2 Revision 0 Section 2 April 5,1995
O sectionx1 category C-D Pmssum Retnining Bolting Greater Than 2"in Diameter i
Total Total Item Description Scheduled Examined Number During During i
Outage Outage Pressure Vessels 1
C(M.010 Bolts and Studs N/A N/A
)
l Piping C04.020 Bolts and Studs N/A N/A i
j Pumps j
C04.030 Bolts and Studs N/A N/A Valves C04.040 Bolts and Studs N/A N/A TOTALS N/A N/A 4
lO 1
i e
i
.4 t
i 1
4 i
i i
O Refueling Outage Report Page 16 McGuire Unit 2 Revision 0 Section 2 April 5,1995
O Section xi cotegory c-r.1 1w ne,-i-i-eweiasinausteoitic Stainle.s Steel or High Alloy Piping Total Total j
Item Description Scheduled Examined Number During During Outage Outage C05.010 Piping Welds 2 3/8" Nominal Wall Thickness for Piping >
NPS 4" j
C05.011 Circumferential Weld 18 18 i
C05.012 Longitudinal Weld
- 5 5
1 1
C05.020 Piping Welds > 1/5" Nominal Wall Thickness for Piping 2 NPS 2" and s NPS 4" C05.021 Circumferential Weld 11 11 C05.022 Longitudinal Weld
- 2 2
i j
l C05.030 Socket Welds 9
9 i
1 C05.040 Pipe Branch Connections O.
of Branch Piping 2 NPS 2" C05.041 Circumferential Weld 1
1 C05.042 Longitudinal Weld
- N/A N/A i
i 1
TOTALS 39 39
1 as required by Table IWC-2500-1, Category C F-1.
However, for reporting purposes, the totals do not reflect the number oflongitudinal welds examined during this outage.
i 4
Refueling Outage Report Page 17 McGuire Unit 2 Revision 0 Section 2 April 5,1995
O Sectionx1 Category C-F 2 Pmssum Hetaining Welds in Carbon orIow AlloySteelPiping Total Total Item Description Scheduled Examined Number During During Outage Outage C05.050 Piping Weid's 2 3/8" Nominal Wall Thickness for Piping >
NPS 4" C05.051 Circumferential Weld 13 13 C05.052 Longitudinal Weld
- 9 9
C05.060 Piping Welds > 1/5" Nominal Wall N/A N/A Thickness for Piping 2 NPS 2" and s NPS 4" C05.061 Circumferential N/A N/A 4
. C05.062 Longitudinal Weld
- N/A N/A C05.070 Socket Welds N/A N/A j
~
gs C05.080 Pipe Branch Connections
()
of Branch Piping 2 NPS 2" N/A N/A C05.081 Circumferential Weld N/A N/A C05.082 Longitudinal Weld
- N/A N/A j
TOTALS 13 13 i
Longitudinal welds that intersect circumferential welds are examined as required by Table IWC 2500-1, Category C F 2.
l However, for reporting purposes, the totals do not renect the number of longitudinal welds examined during this outage.
SectionXICategory C-G Pmssure Retaining Welds in Pumps i
andValves Total Total Item Description Scheduled Examined Number During During Outage Outage Pumps C06.010 Pump Casing Welds N/A N/A Valves C06.020 Valve Body Welds 1
1 TOTALS 1
1 0
Refueling Outage Report Page 18 McGuire Unit 2 Revision 0 Section 2 April 5,1995
f L
- - O sectio =xicatesory c n Aiir-
-net i i eco-Pe eais Total Total Item Description Scheduled Examined 4
Number During During Outage Outage Pressure Vessels l
C07.010 Pressure Retaining COVERED COVERED j
Components IN C07.030 IN C07.030 C07.020 Pressure Retaining COVERED COVERED Components IN C07.040 IN C07.040 1
l Piping j
C07.030 Pressure Retaining 37 37
}
Components C07.040 Pressure Retaining 0-0 Components I
Pumps i
C07.060 Pressure, Retaining COVERED COVERED i
4 Components IN C07.030 IN C07.030 C07.060 Pressure Retaining COVERED COVERED l
Components IN C07.040 IN C07.040 i O veives i
C07.070 Pressure Retaining COVERED COVERED l
Components IN C07.030 IN C07.030 l
C07.080 Pressure Retaining COVERED COVERED l
Components IN C07.040 IN C07.040 i
TOTALS 37 37 i
F1.20 Class 2compone=tSupports
~
Total Total Item Description Scheduled Examined j
Number During During l
Outage Outage j
F1.20 Reference Section 4.0 of 21 W
j-this report i
j TOTALS 27
'll 4
i Refueling Outage Report Page 19 McGuire Unit 2 Revision 0 i
Section 2 April 5,1995 i
i l
O v1.4o soggere.oiserin rigiegsoggerts l
Total Total Item Description Scheduled Examined Number During During Outage Outage F1.40 Reference Section 4.0 of 6
6 this report TOTALS 6
6 F1.50 Class 1,2, & 3 Component Support Snubbers Total Total Item Description Scheduled Examined Number During During Outage Outage F1.50 Reference Section 4.0 of 0
0 this report TOTALS 0
0 l
2.3 Anamented Inanection Total Total Item Description Scheduled Examined Number During During Outage Outage G01.001 RCP Flywheel Exam 2
2 G02.001 S/G (Eddy Current)
G03.001 Pipe Rupture Protection 1
1 I
G04.001 S/G Feedwater Modification 1
1 TOTALS 4
4
- Steam Generator Tubing is examined and documented by the Diversified Services Group of the Electric System Support Department as required by the Station Technical Specifications and is not included in this report. See Eddy Current Examination Report (RFO.9,1995).
l 0 Refueling Outage Report Page 20 McGuire Unit 2 Revision 0 l
Section 2 April 5,1995
i i
2.4 Alternate Examinations i
1 Total Total Item Description Scheduled Examined Number During During Outage Outage None required this outage i
TOTALS 0
0 1
)
A detailed description of each examination listed in Sections 2.1 through 2.4 are located in Section 4 of this report. Results of each examination are located in Section 5 of this report.
i i
7 i
1
- !O f
I t
i i
i i
l l
i.
I i
.i i
i
- O Refueling Outage Report Page 21 1
McGuire Unit 2 Revision 0 Section 2 April 5,1995 i
i 3.0 Second Ten Year Interval Innection Status The completion status of inspections required by.the 1989 ASME Code Section XI is summarized in this section. The requirements are listed by j
the ASME Section XI Examination Category as defined in Table IWB 2500-1 for Class 1 Inspections, in Table IWC-2500-1 for Class 2 Inspections.
Augmented and alternate inspections are also included.
Class 1 Inspections Section i
XI Description Inspections Inspections Percentage IDeferral Category Required Completed Completed Allowed B-A Pressure Retaining Welds 15 welds 1 weld 6.66%
Yes in Reactor Vessel B-B Pressure Retaining Welds in Vessels Other than 5 welds 0 welds O';
No Reactor Vessel B-D Full Penetration Welds of Nozzles'in Vessels 36 inspections 8 inspections 22.22 %
Partial Inspection Program B B-E Pressure Retaining Partial Penetration Welds 55 welds 0 welds 0%
No in Vessels nV B-F Pressure Retaining 46 welds 12 welds 26.08 %
No Dissimilar Metal Welds B-G-1 Pressure Retaining Bolting Greater than 2 Inch 312 items 81 items 25.96 %
No Diameter B-G-2 Pressure Retaining Bolting 2 Inches and Less 19 connections 4 connections 21.05 %
No in Diameter B-H Integral Attachment for 12 attachments 4 attachments 33.33 %
No Vessels BJ Pressure Retaining Welds 191 welds 48 welds 25.13 %
No in Piping B-K-1 Integral Attachments for N/A N/A N/A No Piping, Pumps and Valves i
B-L-1 Pressure Retaining Welds N/A N/A N/A Yes in Pump Casings B-L-2 Pump Casings 1
0 0
Yes B-M-1 Pressure Retaining Welds N/A N/A N/A N/A in Valve Bodies B M-2 Valve Body > 4 in.
6 valves 2 valves 33.33 %
Yes Nominal Pipe Size I
OV Refueling Outage Report Page 1 McGuire Unit 2 Revision 0 Section 3 April 5,1995
r l
Class 1 Inspections (Continued) 1
- l Section XI Description Inspections Inspections Percentage IDeferral
~
Category Required Completed Completed Allowed i
i B-N-1 Interior of Reactor Vessel 3 items 1 item 33.33%
No B-N 2 Integrally Welded Core
}
Support Structures and 2 items 0 items 0%
Yes j
Interior Attachments to Reactor Vessels i
B-N-3 Removable Core Support 1 item 0 items 09 Yes i
Structures 4
B-0 Pressure Retaining Welds 3 welds I weld 33.33%
Yes in Control Rod Housings B-P All Pressure Retaining
{
Components System Leakage Test 6 components 1 component 16.67%
No System Hydrostatic Test I component 0 component 0%
Yes i
B-Q Steam Generator Tubing 100% Station i
Technical N/A l
Specifications l
Met l
F-A Class 1 Component O
v1.1o senne>< <ceae c e n-491) 49 ennert-io sevoerts 20.40, Ne
- Steam Generator Tubing is examined and documented by the Diversified Services Group of i
the Electric System Support Department as required by the Station Technical Specifications and is not included in this report. See Eddy Current Examination Report (RFO 9,1995).
4 4
4 i
1 i
4 I
)
lO Refueling Outage Report Page 2 McGuire Unit 2 Revision 0 j
Section 3 April 5,1995 i
i a
i
)
1 l
Class 2 InspecdonsSection XI Description Inspections Inspections Percentage 1 Deferral Category Required Completed Completed Allowed C-A Pressure Retaining Welds 33 welds 5 ' welds 15.15 %
No in Pressure Vessels l
C-B Pressure Retaining Nozzle 23 welds 3 welds 13.04 %
No Welds in Vessels j
C-C Integral Attachmerts for j
Vessels, Piping, Pumps 16 attachments 2 attachments 12.50%
No and Valves j
C-D Pressure Retaining
{
Bolting Greater Than N/A N/A N/A No 2 Inches in Diameter i
C-F-1 Pressure Retaining Welds in Austenitic Stainless 242 welds 39 welds 16.119 No l
Steel or High Alloy Piping l
C-F-2 Pressure Retaining Welds 2
in Carbon or Low Alloy 55 welds 13 welds 23.639 No Steel Piping C-G Pressure Retaining Welds 8 valves 1 valve 12.50%
No i
in Pumps and Valves C-H All Pressure Retaining
{
Components j
System or Component 88 components 23 components 26.14 %
No Inservice / Functional Test System Hydrostatic Test 44 components 0
0%
Yes FA Class 2 Component 173 supports 27 supports 15.60%
No F1.20 Supports (Code Case N-491)
I i
4 O
Refueling Outage Report Page 3 McGuire Unit 2 Revision 0 Section 3 April 5,1995
.r w,
~.
--i-y
.9
.m
Additional Component Support Examinations Class 1,2 & 3 Section XI Description Inspections Inspections Percentage IDeferral Category Required Completed Completed Allowed F-A Supports other than Piping 29 Supports 6 Supports 20.689 No F1.40 Supports Class 1,2 & 3 i
F1.50 Class 1,2 & 3 Snubber 359 Snubbers O Snubbers 09 No l
Examinations 4
l 1
Deferral ofinspection to the end of the interval as allowed by ASME Section XI Tables IWB-2500-1 and IWC-2500-1.
Augmented Inspections j
Augmented Description Inspections Inspections Percentage Required Completed Completed G01.001 Reactor Coolant Pump 20 inspections 2 inspections 10%
Flywheel Examinations l
G02.001 Steam Generator Preheater Section Tube Examinations G03.001 Pipe Rupture Protection
$7 elds I weld 12.50%
G04.001 Steam Generator 1
1 Feedwater Modification xxx xxx 1
- Steam Generator Tubing is examined and documented by the Diversified Services Group of the Electric System Support Department as required by the Station Technical Specifications and is not included in this report. See Eddy Current Examination Report (RFO-9,1995).
xxx 100% of Requirements Met for Outage 9.
Alternate InspectionsSection XI Inspections inspections Percentage IDeferral Category Description Required Com'pleted Completed Allowed
]
N/A N/A N/A N/A N/A N/A 1
Deferral ofinspection to the end of the interval as allowed by ASME Section XI Tables IWB-2500-1 and IWC-2500-1.
0 V
Refueling Outage Report Page 4 l
McGuire Unit 2 Revision 0 Section 3 April 5,1995
p 4.0 Finni Inmarvice Inanection Plan For Outnae 9 d
The final ISI Plan presented in this section lists all examinations credited for Outage 9 at McGuire Unit 2. This includes ASME Section XI Class 1 and 2, augmented and any alternate examinations required by the plant technical specifications, NRC Bulletins and Problem Investigation Process Forms.
4.1 The information shown below is a field description for the reporting format included in this section of the report:
A.
Items examined by NDE methods Item Number
= ASME Section XI Tables IWB-2500-1 (Class 1),IWC-2500-1 (Class 2),
IWF-2500-1 (Class 1, Class 2),
Augmented and Alternate Requirements ID Number
= Unique Identification Number Drawing Number
= Location and/or Detail Drawing Locs.
= Location O
Insp. Req.
= Examination Technique - Magnetic Particle, Dye Penetrant, etc.
Proc. Numbers
= Examination Procedures Material Type / Grade = General Description of Material Diam./ Thick
= Diameter / Thickness Calib. Block
= Calibration Block Number Comments
= General and/or Detail Description i
O Refueling Outage Report Page1 McGuire Unit 2 Revision 0 Section 4 April 5,1995
O O
O CATEGORY B-A. Pressure Retainina Welds OUALITY A SURANCE ECHNICAL SERVICES in Reactor Vessel in rvie. in p.cison o.i.n.
ns n g.m.nt system Plan Report McGuire Unit 2 Page1 inservice inspection Plan for interval 2 Outage 1 M/05/ms ITEM NUMBER ID NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENTS
- - Circumferential..
B01.021.002 2RPV-W01 MCM 2201.01-01 ISI-138 UT CS 0.000 50301 PC.02 to PC 01 Lower Head to Bottom Head Weki Circumferential MCM 2201.01-019 NDE1003 5.300 50302 (Circumferential Weld)
CAL BLOCK NDE-620 PC.02 Lower Head to PC.01 Bottom Head 50304,50509,30738 Tot.1 B01.021 Items:
1 k
4 4
.m
O O
O CATEGORY B-A. Pressure Retainina Welds MP Y QUALITY A RA C
( SERVICES in Reactor Vessel in.orvic. in.pection pet bes. Men gement System Plan Report McGuire Unit 2 Page 2 M
inservice inspection Plan for Interval 2 Outage 1 04/05/ms ITEM NUMBER 10 NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENTS B01.030 001 2RPV-WO7 MCM 2201.01-052 NDE-650 UT CS 0.000 50304 PC.07 to PC.06 FLG. to Upper Shell(Noz. Belt)
Circumferential MCM 2201.01-019 10.900 UT from Flange Surf ace (Circumferential Weld)
PC.07 R V Flange to PC.06 Upper Shell Total 901.030 hems:
1 Total Category B-A Items:
2 a
O O
+
N
O O
O CATEGORY B-D. Full Penetration Welds of OUAUTY A SURANC EC f# CAL SERVICES Nozzels in Vessels in.orvice in.p.ction o.t.n..e M.n.gement System Plan Repori Reactor Vessel McGuire Unit 2 Page 3 Inservice inspection Plan for Interval 2 Outage 1 04/05" 995 ITEM NUMBER ID NUMBER ISO /DWG NUMBERS PROC INSPREO MAT /SCH DIA/THK CAL BLOCKS COMMENTS
-+ Nozzle-to-Vessel Welds -
B03.090.005A 2RPV-W15 MCM 2201.01-001 ISI-138 UT CS 52.900 50304 22 Deg. Outlet Nozzle to Shell Weld Circumferential MCM 2201.01-019 10.900 (UT from Nozzle ID)
Outlet Nozzle to Shell See Request for Reisel 93-005 803.090.006A 2RPV-W16 MCM 2201.01-001 ISI-138 UT CS 52.900 50304 158 Deg. Outlet Nozzle to Shell Weld Circumferential MCM 2201.01-019 10.900 (UT from Nozzle 10)
~
Outlet Nozzle to Shell See Request for Remf 03-005 B03.090.007A 2RPV-W17 MCM 2201.01-001 ISI-138 UT CS 52.900 50304 202 Deg. Outlet Nozzle to Shell Weld Circumferential MCM 2201.01-019 10.900 (UT from Nozzle ID)
Outlet Nozzle to Shell See Request for Relief 93-005 B03.090 008A 2RPV-W i8 MCM 2201.01-001 ISI-138 UT CS 52.900 50304 338 Deg. Outlet Nozzle to Shell Weld Circumferential MCM 2201.01-019 10.900 (UT from Nozzle ID)
Outlet Nozzle to Shell See Request for Relie193-005 Total 803.090 items:
4 i
i
O O
O CATEGORY B-D. Full Penetration Welds of QUALITY ASSURANCE CHNICAL SERVICES Nozzels in Vessels inservice inspection Database Management Syst.m Plan Report Reactor Vessel McGuire Unit 2 Page 4 :
Inservice inspection Plan for interval 2 Outage 1 04'05'1985' ITEM NUMBER 10uuMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENTS
- Nozzle inside Radius Section -
B03.100.005 2RPV-W '5 MCM 2201.01-001 ISI-138 UT CS 52.900 50304 22 Deg Outlet Nozzle to Shell Weld (Insde Radius)
Circumferential MCM 2201.01-019 10.900 (UT from Nozzle ID)
Outlet Nozzle to Shell See Request for Rehef 93-005 B03.100.006 2RPV-W16 MCM 2201.01-001 ISI-138 UT CS 52.900 50304 158 Deg. Outlet Nozzle to Shell Weld (Inside Radius)
Circumferential MCM 2201.01-01?
10.900 (UT from Nozz!e ID)
Outlet Nozzle to Shell See Request for Rehef 93-005 B03.100.007 2RPV-W17 MCM 2201.01-001 ISI-138 UT CS 52.900 50304 202 Deg. Outlet Nozzle to Shell Weld (Inside Radius)
Crcumferential MCM 2201.01-019 10.900 (UT from Nozzle ID)
Outlet Nozzle to Shel' See Request for Rehef 93-005 B03.100.008 2RPV-W18 MCM 2201.01-001 ISI-138 UT CS 52.900 50304 338 Deg. Outlet Nozzle to Shell Weld (Inside Radius)
Circumferential MCM 2201.01-019 10.900 (UT from Nozzle ID)
Oif.;et Nozzle to Shell See Request for Rehef 93-005 Tot:I B03.100 Items:
4
~~
-O O
O CATEGORY B-D. Full Penetration Welds of KE POW "
^"
Nozzels in Vessels OVALITY A Sup,gE C AL SERVICES inservice inspection Database Management System Plan Report Steam Generators (Primary Side)
McGuire Unit 2 Page 5 Inservice inspection Plan for interval 2 Outage 1 04/05/m5 ITEM NUMBER ID NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENTS
~~. Nozzle inside Radius Section --
B03.140.001 2SGA-INLET MCM 2201.01-011 NDE-680 UT CS 39.000 50302 STEAM GENERATOR 2A PRIMARY INLEI NOZZ1 E Circumferential MCM 2201.01-480 7.450 RADIUSED SECTION B03.140.002 2SGAOUTLET MCM 2201.01-011 '
NDE-680 UT CS 39.000 50302 STEAM GENERATOR 2A PRIMARY OUTLET NOZZ1 E Circumferential MCM 2201.01-480 7.450 RADIUSED SECTION Total 903.14011 ems:
2 Total Category B-D ltems:
10
O O
O CATEGORY B-F. Pressure RetaininQ QUAUTY A RANCE ECHNICAL SERVICES Dessimilar Metal Welds inservice inspection Database Management System Plan Report McGuire Unit 2 Page 6 3
inservice inspection Plan for interval 2 Outage 1 04'05'1995 ITEM NUMBER lD NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENTS
- NPS 4 or larger; Nozzle-to Safe End Butt Welds - -
B05.010.005 2RPV-W15-SE MCM 2201.01-18/1 ISI-138 UT SS/CS 29.000 50214 RV OUTLET NOZZLE TO SAFE END 22 DEG. UT Circumferential MCM 2201.01-0010 2.312 50304 FROM NOZZLE SIDE. REF. REQUEST FOR RELIEF RV OUTLET NOZZLE to SAFE END 93-005, B&W 1993 RPV REPORT.
Drssimilar TO BE DONE WITH B05.130 001 B05.010.005A 2RPV-W15-SE MCM 2201.01-18/1 ISI-138 UT SS/CS 29.000 50214 RV OUTLET NOZZLE TO SAFE END 22 DEG. UT Circumferential MCM 2201.01-0010 2.312 50304 FROM PIPE SIDE. REF. REQUEST FOR RELIEF RV OUTLET NOZZLE to SAFE END 93-005. B&W 1993 RPV REPORT.
Dissimilar TO BE DONE WITH B05.130.001 A B05.010.0058 2RPV-W15-SE MCM 2201.01-18/1 NDE-35 PT SS/CS E 000 RV OUTLET NOZZLE TO SAFE END 22 DEG.
Circumferential MCM 2201.01-0010 2.312 TO BE DONE WITH B05.130.001B RV OUTLET NOZZLE to SAFE END Dissimilar B05.010.006 2RPV-W16-SE MCM 2201.01-18/4 ist-138 UT SS/CS 29.000 50214 RV OUTLET NOZZLE TO SAFE END 158 DEG. UT Circumferential MCM 2201.01-0010 2.312 50304 FROM NOZZLE SIDE. REF. REQUEST FOR REUEF RV OUTLET NOZZLE to SAFE END 93 005. B&W 1993 RPV REPORT.
Dissimilar TO BE DONE WITH B05.130.005 B05.010.006A 2RPV-W16-SE MCM 2201.01-18/4 ISI-138 UT SS/CS 29.000 502:4 RV OUTLET NOZZLE TO SAFE END 158 DEG. UT Circumferential MCM 2201.01-0010 2.312 5030L1 FROM PIPE SIDE. REF. REQUEST FOR RELIEF RV OUTLET NOZZLE to SAFE END 93-005, B&W 1993 RPV REPORT.
Dissimilar TO BE DONE WITH B05.130.005A l
805.010.006B 2RPV-W16-SE MCM 2201.01-18/4 NDE-35 PT SS/CS 29.000 RV OUTLET NOZZLE TO SAFE END 158 DEG.
Circumferential MCM 2201.01-0010 2.312 TO BE DONE WITH B05.130.005B RV OUTLET NOZZLE to SAFE END Dissimilar i 805.010.007 2RPV-W17-SE -
MCM 2201.01-18/7 ISI-138 UT SS/CS 29.000 50214 RV GUTLET NOZZLE TO SAFE END 232 DEG. UT 1
Circumferential MCM 2201.01-0010 2.312 50304 FROM NOME 5:9E. REF. REQUEST FOR REllEF RV OUTLET NOZZLE to SAFE END 93-005, B&W 1993 RPV REPORT.
Dissimilar TO BE DONE WITH B05.130.009.
i B05.010.007A 2RPV-W17-SE MCM 2201.01-18/7 ISl-138 UT SS/CS 29.000 50214 RV OUTLET NOZZLE TO SAFE END 202 DEG. Ur Circumferential MCM 2201.01-0010 2.312 50304 FROM PIPE SIDE. REF. REQUEST FOR fiFi IEf-1 RV OUTLET NOZZLE to SAFE END 93-005. B&W 1993 RPV REPORT.
I Dissimilar TO BE DONE WITH B05.130.009A B05.010.0078 2RPV-W17-SE MCM 2201.01-18/7 NDE-35 PT SS/CS 29.000 RV OUTLET NOZZLE TO SAFE END 202 DEG.
Circumferential MCM 2201.01-0010 2.312 TO BE DONE WITH B05.130.009B l
HV OUTLET NOZZLE to SAFE END Dissimilar B05.010.008 2RPV-W18-SE MCM 2201.01-19 ISI-138 UT SS/CS 29.000 50214 RV OUTLET NOZZLE TO SAFE END 338 DEG. UT 4
Circumferential MCM 2201.01-0010 2.312 50304 FROM NOZZLE SIDE. P.EF REQUEST FOR RELIEF RV OUTLET NOZZLE to SAFE END 93-005, B&W 1993 RPV REPOH i'.
Dissimilar TO BE DONE WITH B05.130.013 a
1
O O
O CATEGORY B-F. Pressure Retaining KEPOWE C OUALM ASS p gE C NICAL SERVICES Dissimilar Metal Welds in evic. in.p.ction D.i.ba Men g.m.ni system Plan Report V
McGuir. Unit 2 Pag. 7 M/05/1995 W
Inservice inspection Plan for interval 2 Outage 1 ITEM NUMBER ID NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENTS B05.010.008A 2RPV-W18-SE MCM 2201.01-19 ISI-138 UT SS/CS 29.000 50214 RV OUTLET NOZZLE TO SAFE END 338 DEG UT Circumferential MCM 2201.01-0010 2.312 50304 FROM PIPE SIDE. REF. REQUEST FOR REllEF RV OUTLET NOZZLE to SAFE END 93-005. B&W 1993 RPV REPORT.
Dessimilar TO BE DONE WITH B05.130.013A B05.010.008B 2RPV-W18-SE MCM ?201.01-19 NDE-35 PT SS/CS 29.000 RV OUTLET NOZZLE TO SAFE END 338 DEG Circumferential MCM 2201.01-0010 2.312 TO BE DONE WITH B05.130.0138 RV OUTLET NOZZLE to SAFE END Dessimilar Tot.1 B05.010 ftoms:
-12
O O
O CATEGORY B-F. Pressure Retainine K POW "
OUALITY A SURA EE At. SERVICES Dissimilar Metal Welds in evic. insp.ctw o.iab u n.g.m.nt System Plan R port Steam Generator McGuir. Unit 2 Pag. 8 04/05/m5 Inservice Inspection Plan for Interval 2 Outage 1 ITEM NUMBER ID NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS CO*.iMENIS NPS 4 or Larger; Nozzle-to-Safe End Butt Welds -
B05.070.001 2SGA-INLET-SE NDE-610 UT SS/CS 31.000 50214 SG2A INLET NOZZLE SAFE END.
Circumferential MCM 2201.01-18/1 2.500 TO BE DONE WITH B05.130 002 MCM 2201.01-11 INLET NOZZLE to SAFE END Drssimilar BOS 070.001 A 2SGA-INLET-SE NDE-35 PT SS/CS 31.000 SG2A INLET NOZZLE SAF E END Circumferential MCM 2201.01-18/1 2.500 TO BE DONE WITH B05.130.002A MCM 2201.0'1-11 INLET NOZZLE to SAFE END Dissimilar D05.070.002 2SGA-OUTLET-SE NDE-610 UT SS/CS 31.000 50214 SG2A OUTLET NOZZLE SAFE END Circumferential MCM 2201.01-18/2 2.500 TO BE DONE WITH B05.130 003 MCM 2201.01-11 OUTLET NOZZLE to SAFE END Dissimilar B05.070 002A 2SGA-OUTLET-SE NDE-35 PT SS/CS 31.000 SG2A OUTLET NOZZLE SAFE END.
Circumferential MCM 2201.01-18/2 2.500 TO BE DONE WITH B05.130.OO3A MCM 2201.01-11 OOTLET NOZZLE to SAFE END Dissimilar Tctal B05.070 items:
4
O O
O CATEGORY B-F. Pressure Retainin0 QUALITY ASSURANCE CHNICAL SERVICES Dissimilar Metal Welds inservice in.p.ction D.i.be.e M.n.gement System Plan Report pggna McGuire Unit 2 Page 9 Inservice inspection Plan for Interval 2 Outage 1 04/05/1995 ITEM NUMBER ID NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENTS
- NPS 4 or Larger; Dissimilar Metal Butt Welds -
B05.130.001 2NC2F-1-1 ISI-138 UT SS/CS 29.000 50214 UT FROM SAFE END SIDE REF RFR 93-005, B&W Circumferential MCM 2201.01-18/1 2.300 50304 1993 RPV REPORT MCM 2201.01-10 NOZZLE to SAFE END TO BE DONE WITH B05.010.005 Dissimilar 805.130.001 A 2NC2F-1-1 ISI-138 UT SS/CS 29.000 50214 UT FROM PIPE SIDE.REF RFR 93-005. B&W 1993 BPV Circumferential MCM 2201.01-18/1 2.300 50304 REPORT
^
MCM 2201.01-10 Pipe to SAFE END TO BE DONE WITH BOS 010.005A Dissimilar 805.130.001 B 2NC2F-1-1 NDE-35 PT SS/CS 29.000 TO BE DONE WITH B05.010.005B Circumferential MCM 2201.01-18/1 2.300 MCM 2201.01-10 Poe to SAFE END Dissimilar 805.130.002 2NC2F-1-2 NDE-610 UT SS/CS 31.000 50214 UT FROM ELBOW SIDE Circumferential MCM 2201.01-18/1 2.500 TO BE DONE WITH B05.070.001 MC 2676-4 Elbow to SG2A Dissimilar 805.130.002A 2NC2F-1-2 NDE-35 PT SS/CS 31.000 TO BE DONE WITH B05.070.001 A Circumferential MCM 2201.01-18/1 2.500 MC 2676-4 Elbow to SG2A Dissimilar 805.130.003 2NC2F-1-3 NDE-610 UT SS/CS 31.000 50214 UT FROM ELBOW SIDE Circumferential MCM 2201.01-18/2 2.500 TO BE DONE WITH B05.070.002 MC 2676-4 Elbow to SG2A 1
Dissimilar 805,130.003A 2NC2F-1-3 NDE-35 PT SS/CS 31.000 TO BE DONE WITH B05.070.002A Circumferential MCM 2201.01-18/2 2.500 MC 2676-4 Ebow to SG2A Dissimilar '
B05.130.005 2NC2F-2-1 ISI-138 UT SS/CS 29.000 50214 UT FROM SAFE END SIDE Circumferential MCM 2201.01-18/4 2.300 50304 REF. RFR 93-005, B&W 1993 RPV REPORT MCM 2201.01-10 Nozzle to SAFE END TO BE DONE WITH B05.010.006 Dissimilar B05.130.005A 2NC2F-2-1 ISI-138 UT SS/CS 29.000 50214 UT FROM PIPE SIDE Circumferential MCM 2201.01-18/4 2.300 50304 REF. RFR 93-005, B&W 1993 RPV REPORT MCM 2201.01-10 Ppe to SAFE END TO BE DONE WITH B05.010.006A Dissimilar B05.130.005B 2NC2F-2-1 NDE-35 PT SS/CS 29.000 TO BE DONE WITH B05.010.006B Circumferential MCM 2201.01-18/4 2.300 MCM 2201.01-10 Pipe to SAFE END Dissimilar
O O
O CATEGORY B-F. Pressure Retaining QUALITY ASSURA E CHNICAL SERVICES Dissimilar Metal Welds ins.rvice inspection Det. base Management System Plan Report McGuire Unit 2 Page to Inservice inspection Plan for interval 2 Outage 1 04/05/ms ITEM NUMBER ID NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENTS B05.130.009 2NC2F-3-1 ISI-138 UT SS/CS 29.000 50214 UT FROM SAFE END SIDE Circumferential MCM 2201.01-18/7 2.300 50304 REF. RFR 93-005, B&W 1993 RPV REPCRT MCM 2201.01-10 Nozzle to SAFE END TO BE DONE WITH B05.010.007 Dissimilar 805.130.009A 2NC2F-3-1 ISI-138 UT SS/CS 29.000 50214 UT FROM PIPE SIDE Circumferential MCM 2201.01-18/7 2.300 50304 REF. RFR 93-005 B8W 1993 RPV REPORT MCM 2201.01-10 SAFE END to Ppe TO DE DONE WITH B05 010.007A Dissimilar 805.130.009B 2NC2F-3-1 NDE-35 PT SS/CS 29.000 TO BE DONE WITH BOS 010.007B Circumferential MCM 2201.01-18/7 2.300 MGM 2201.01-10 SAFE END to Ppe Dissimilar 805.130.013 2NC2F-4-1 ISI-138 UT SS/CS 29.000 50214 UT FROM SAFE END SIDE Cucumferential MCM 2201.01-18/10 2.300 50304 REF. RFR 93 005, B&W 1993 RPV REPORT MCM 2201.01-10 Nozzle to SAFE END TO BE DONE WITH B05.010.008 Dessumlar 805.130 013A 2NC2F-4-1 ISI-138 UT SS/CS 29.000 50214 UT FROM PIPE SIDE Cucumferential MCM 2201.01-18/10 2.300 50304 REF. RFR 93-005 B&W 1993 RPV REPORT MCM 2201.01-10 Ppe to SAFE END TO BE DONE WITH B05.010.008A l
Dissimilar l
B05.130.013B 2NC2F-4-1 NDE-35 PT SS/CS 29.000 TO BE DONE WITH B05.010.0088 Circumferential MCM 2201.01-18/10 2.300
{
MCM 2201.01-10 Ppe to SAFE END Dissimilar Tot.1 B05.130 Itoms:
16 Tot.1 Category B-F Items:
32
. _. _ =. -.
O O
O CATEGORY B-G-1. Pressure RetaininQ KE WE COMPANY OUALITY A e
, SERVICES Bolting. Greater than 2"In Diameter Inservice inspection Database "" 7.
.t System Plan Report gg McGuire Unit 2 Page 11 inservice inspection Plan for Interval 2 Outage 1
"* '8 5 ITEM NUMBER IDNUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENTS
- Closure Head Nuts -
806.010.001 2RPV-664-32-01 MCM 2201.01-21 NDE-25 MT CS 10.540 REACTOR VESSEL CLOSURE HEAD NUTS RDM 307381544 1.770 B06.010.002 2RPV-664-32-02 MCM 2201.01-21 NDE-25 MT CS 10.540 REACTOR VESSEL CLOSURE HEAD NUTS 4
RDM 30738,1544 1.770 806.010.003 2RPV-664-32-03 MCM 2201.01-21 NDE-25 MT CS 10.540 REACTOR VESSEL CLOSURE HEAD NUTS RDM 30738-1544 1.770 B06.010.004 2RPV-664-32-04 MCM 2201.01-21 NDE-25 MT CS 10.540 REACTOR VESSEL CLOSURE HEAD NUTS RDM 30738-1544 1.770 B06.010.005 2RPV-664-32-05 MCM 2201.01-21 NDE-25 MT CS 10*'3 REACTOR VESSEL CLOSURE HEAD NUTS RDM 30738-1544 1
,0 B06.010.006 2RPV-664-32-06 MCM 2201.01-21 NDE-25 MT CS 10.540 REACTOR VESSEL CLOSURE HEAD NUTS RDM 30738-1544 1.770 B06.010.007 2RPV-66442-07 MCM 2201.01-21 NDE-25 MT CS 10.540 REACTOR VESSEL CLOSURE HEAD NUTS RDM 30738-1544 1.770 806.010.008 2RPV-664-32-08 MCM 2201.01-21 NDE-25 MT CS 10.540 REACTOR VESSEL CLOSURE HEAD NUTS RDM 30738-1544 1.770 B06.010.009 2RPV-664-32-09 MCM 2201.01-21 NDE-25 MT CS 10.540 REACTOR VESSEL CLOSURE HEAD NUTS RDM 30738-1544 1.770 Total 806.010 items:
9 L
O O
0:
DUKE POWER COMPANY CATEGORY B-G-1. Pressure Retainin0 OUALITY ASSURANCE TECHleCAL SERVICES i
Botting. Greater than 2"in Diameter in n, ice in.p.etion D.m -_.
..t Sy.iem Plan Report McGuire Unit 2 Page 12
" 1885 '
Inservice inspection Plan for laterval 2 Outage 1 ITEM NUMBER ID NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENTS
-l
- = Closure Studs, when removed. -
B06.030.001 2RPV-664-31-01 MCM 2201-01-21 NDE-942 UT CS 7.000 50501 CLOSURE STUD i
ROM 30738-1544 64.560 1 B06.030.001A 2RPV-664-31-01 MCM 2201-01-21 NDE-25 MT CS 7.000 CLOSURE STUD RDM 30738-1544 64.560 i
B06.030.002 2RPV-664-31-02 MCM 2201-01-21 NDE-942 UT CS 7.000 50501 CLOSURE STUD i
RDM 30738-1544 64.560 B06.030.002A 2RPV-664-31-02 MCM 2201-01-21 NDE-25 MT CS 7.000 CLOSURE STUD RDM 30738-1544 64.560 B06.030.003 2RPV-664-31-03 MCM 2201-01-21 NDE-942 UT CS 7.000 50501 CLOSURE STUD i
RDM 30738-1544 64.560 l B06.030.003A
- 2RPV-664-31-03 MCM 2201-01-21 NDE-25 MT CS 7.000-CLOSURE STUD RDM 30738-1544 64.560 v
i
- 906.030.004 2RPV-664-31-04 MCM 2201-01-21 NDE-942 UT CS 7.000 50501 CLOSURE STUD
?
RDM 30738-1544 64.560 4
- 806.030.004A 2RPV-664-31-04 MCM 2201-01-21 NDE-25 MT CS 7.000 CLOSURE STUD RDM 30738-1544 64.560 l B06.030.005 2RPV-664-31-05 MCM 2201-01-21 NDE-942 UT.
CS 7.000, 50501 CLOSURE STUD RDM 30738-1544 64.560 l-
' B06.030.005A 2RPV-664-31-05 MCM 2201-01-21 NDE-25 MT CS 7.000 CLOSURE STUD 4
RDM 30738-1544 64.560-s
O O
O CATEGORY B-G-1. Pressure RetaininQ OUALITY A SURANCE EC NICAL SERVICES Boltina. Greater than 2"in Diameter Inservice inspection Database Management System Plan Report i
Reactor Vessel McGuire Unit 2 Page 13 inservice inspection Plan for Interval 2 Outage 1 04/05/1995 ITEM NUMBER ID NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/TilK CAL BLOCKS COMMENTS B06.030.006 2RPV-664-31 -06 MCM 2201-01-21 NDE-942 UJ CS 7.000 50501 CLOSURE STUD l
RDM 30738-1544 64.560 806.030.006A 2RPV-664-31-06 MCM 2201-01-21 NDE-25 MT CS 7.000 CLOSURE STUD RDM 30738-1544 64.560 B06.030.007 2RPV-664-31-07 MCM 2201-O'l-21 NDE-942 UT CS 7.000 50501 CLOSURE STUD RDM 30738-1544 64.560 l
B06.030.007A 2RPV-664-31-07 MCM 2201-01-21 NDE-25 MT CS 7.000 CLOSURE STUD RDil 30738-1544 64.560 806.030.008 2RPV-664-31-08 MCM 2201-01-21 NDE-942 UT CS 7.000 50501 CLOSURE STUD RDM 30738-1544 64.560 B06.030.008A 2RPV-664-31-08 MCM 2201-01-21 NDE-25 MT CS 7.000 CLOSURE STUD RDM 30738-1544 64.560 806.030.009 2RPV-664-31-09 MCM 2201-01-21 NDE-942 UT CS 7.000 50501 CLOSURE STUD RDM 30738-1544 64.560 806.030.009A 2RPV-664-31-09 MCM 2201-01-21 NDE-25 MT CS 7.000 CLOSURE STUD RDM 30738-1544 64.560 Total B06.03011 ems:
18
O O
O 3
CATEGORY B-G-1. Pressure Retainina QUALITY A RANCE CHNICAL SERVICES Boltina. Greater than 2"in Diameter in.orwice inspection Dotatmee Management System Plan Report McGuire Unit 2 Page 14 Inservice inspection Plan for Interval 2 Outage 1 04 m/ m s ITEM NUMBER 10 NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENTS
. + Threads in Flange..
806.040.001 2RPV THREAD 01 MCM 2201.01-1 NDE-640 UT CS 0.000 40387 THREADS IN RPV FLANGE 0.000 806.040.002 2RPV-THREAD-02 MCM 2201.01-1 NDE-640 UT CS 0.000 40387 THREADS IN RPV FLANGE 0000 806.040.003 2RPV-THREAD-03 MCM 2201.01-1 NDE-640 UT CS 0.000 40387 THREADS IN RPV FLANGE 0.000 B06.040.004 2RPV-THREAD 04 MCM 2201.01-1 NDE-640 UT CS 0.000 40387 THREADS IN RPV FLANGE 0.000 806.040 005 2RPV-THREAD-05 MCM 2201.01-1 NDE-640 UT.
CS 0.000 40387 THREADS IN RPV FLANGE j
0.000 B06.040.006 2RPV-THREAD-06 MCM 2201.01-1 NDE-640 UT CS 0.000 40387 THREADS IN RPV FLANGE O.000 l
B06.040.007 2RPV-THREAD-07 MCM 2201.01-1 NDE-640 UT CS 0.000 40387
- THREADS IN RPV FLANGE 0.000 B06.040.008 2RPV-THREAD-08 MCM 2201.01-1 NDE-640 UT CS 0.000 40387 THREADS IN RPV FLANGE 0.000 1
B06.040.009 2RPV-THREAD-09 MCM 2201.01-1 NDE-640 UT CS 0.000 40387 THREADS IN RPV FLANGE '
O.000 B06.040.010 2RPV-THREAD-10 MCM 2201.01-1 NDE-640 UT CS 0.000 40387 THREADS IN RPV FLANGE 0.000
O O
O CATEGORY B-G-1. Pressure Retaining OUALITY A SURANCE C NICALSERViCES Bolting. Greater than 2" In Diameter ins.rvic. inspection Databen. Managern.ni Sysiern Plan Report Reactor Vessel McGuir. Unit 2 Page 15 04/05/m5 Inservice inspection Plan for interval 2 Outage 1 ITEM NUMBER 10 NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/iHK CAL BLOCKS COMMENTS B06.040.011 2RPV-THREAD-11 MCM 2201.01-1 NDE-640 UT CS 0.000 40387 THREADS IN RPV FLANGE 0.000 806 040.012 2RPV-THREAD-12 MCM 2201.01-1 NDE-640 UT CS 0.000 40387 THREADS IN RPV FLANGE 0.000 806.040 013 2RPV-THREAD-13 MCM 220151-1 NDE-640 UT CS 0.000 40387 THREADS IN RPV FLANGE 0.000 B06.040.014 2RPV-THREAD-14 MCM 2201.01-1 NDE-640 UT CS 0.000 40387 THREADS IN RPV FLANGE 0.000 B06 040 015 2RPV-THREAD-15 MCM 2201.01-1 NDE-640 UT CS 0.000 40387 THREADS IN RPV FLANGE 0.000 B06.040.016 2RPV-THREAD-16 MCM 2201.01-1 NDE-640 UT CS 0.000 40387 THREADS IN RPV FLANGE O.000 B06.040.017 2RPV-THREAD-17 MCM 2201.01-1 NDE-640 UT CS 0.000 40387 THREADS IN RPV FLANGE 0.000 806.040.018 2RPV-THREAD-18 MCM 2201.01-1 NDE-640 UT CS 0.000 40387 THREADS IN RPV FLANGE 0.000 B06.040.019 2RPV-THREAD-19 MCM 2201.01-1 NDE-640 UT CS 0.000 40387 THREADS IN RPV FLANGE 0.000 B06.040.020 2RPV-THREAD-20 MCM 2201.01-1 NDE-640 UT CS 0.000 40387 THREADS IN RPV FLANGE 0.000
O O
O CATEGORY B-G-1. Pressure Retainina QUAUTY ASSURANCE EC NICAL SERVICES Bottina. Greater than 2" In Diameter Inservice Mspection Database Management System Plan Report Reactor Vessel McGuire Unit 2 Page 16 Inservice inspection Plan for interval 2 Outage 1 04/05/1995 ITEM NUMBER ID NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENTS B06.040.021 2RPV THREAD-21 MCM 2201.01-1 NDE-640 UT CS 0.000 40387 THREADS IN RPV FLANGE 0.000 B06.040.022 2RPV-THREAD-22 MCM 2201.01-1 NDE-640 UT CS 0.000 40387 THREADS IN RPV FLANGE 0.000 B06.040.023 2RPV-THREAD-23 MCM 2201.01-1 NDE-640 UT CS 0.000 40387 THREADS IN RPV FLANGE 0.000 B06.040.024 2RPV-THREAD-24 MCM 2201.01-1 NDE-640 UT CS 0.000 40387 THREADS IN RPV FLANGE 0.000 806 040.025 2RPV-THREAD-25 MCM 2201.01-1 NDE-640 UT CS 0.000 40387 THREADS IN RPV FLANGE 0.000 B06.040.026 2RPV-THREAD-26 MCM 2201.01-1 NDE-640 UT CS 0.000 40387 THREADS IN RPV FLANGE 0.000 I
B06.040.027 2RPV-THREAD-27 MCM 2201.01-1 NDE-640 UT CS 0.000 40387 THREADS IN RPV FLANGE 0.000
)
806.040.028 2RPV-THREAD-28 MCM 2201.01-1 NDE-640 UT CS 0.000 40387 THREADS IN RPV FLANGE O.000 B06.040.029 2RPV-THREAD-29 MCM 2201.01-1 NDE-640 UT CS 0.000 40387 THREADS IN RPV FLANGE 0.000 B06.040.030 2RPV-THREAD-30 MCM 2201.01-1 NDE-640 UT CS 0.000 40387 THREADS IN RPV FLANGE.
0.000
O O
O CATEGORY B-G-1. Pressure RetaininQ QUALITY A SUR E CHNICAL SERVICES Bolting. Greater than 2" In Diameter Inservice inspection Database Management system Plan Report Reactor Vesset McGuire Unit 2 Page 17 Inservice inspection Plan for Interval 2 Outage 1 m/05/ms ITEM NUMBER 10 NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENTS B06.040.031 2RPV-THREAD-31 MCM 2201.0:-1 NDE-640 UT CS 0.000 40387 THREADS IN RPV FLANGE 0.000 i
B06.040.032 2RPV-THREAD-32 MCM 2201.01-1 NDE-640 UT CS O000 40387 THREADS IN RPV FLANGE 0.000 l
B06.040.033 2RPV-THREAD-33 MCM 2201.01-1 NDE-640 UT CS 0.000 40387 THREADS IN RPV FLANGE 0.000 B06.040.034 2RPV-THREAD-34 MCM 2201.01-1 NDE-640 UT CS
, 0.000 40387 THREADS IN RPV FLANGE 0.000 806.040.035 2RPV-THREAD-35 MCM 2201.01-1 NDE-640 UT CS 0.000 40387 THREADS IN RPV FLANGE 0.000 B06.040.036 2RPV-THREAD-36 MCM 2201.01-1 NDE-640 UT CS 0.000 40387 THREADS IN RPV FLANGE O.000 B06.040.037 2RPV-THREAD-37 MCM 2201.01-1 NDE-640 UT CS 0.000 40387 THREADS IN RPV FLANGE 0.000 B06.040.038 2RPV-THREAD-38 MCM 2201.01-1 NDE-640 UT CS 0.000 40387 THREADS IN RPV FLANGE 0.000 B06.040.039 2RPV-THREAD-39 MCM 2201.01-1 NDE-640 UT CS 0.000 40387 THREADS IN RPV FLANGE 0.000 806.040.040 2RPV-THREAD-40 MCM 2201.01-1 NDE-640 UT CS 0.000 40387 THREADS IN RPV FLANGE 0.000
= - -.
- ~.
O O
O CATEGORY B-G-1. Pressure RetaininQ OUALITY ASSURANCE CHNICAL SERVICES Boltina. Greater than 2"in Diameter inservice inspection Database mannagement System Plan Report Reactor Vessel McGuire Unit 2 Page 18 moses Inservice inspection Plan for interval 2 Outage 1 ITEM NUMBER ID NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENTS B06.040.041 2RPV-THREAD 41 MCM 2201.01-1 NDE-640 U,T CS 0.000 40387 THREADS IN RPV FLANGE 0.000 806.040.042 2RPV-THREAD-42 MCM 2201.01-1 NDE-640 UT CS 0.000 40387 THREADS IN RPV FLANGE O000 B06.040.043 2RPV-THREAD-43 MCM 2201.0'1-1 NDE-640 UT CS 0.000 40387 THREADS IN RPV FLANGE 0.000 B06.040.044 2RPV-THREAD-44 MCM 2201f1 1 NDE-640 UT CS 0.000 40387 THREADS IN RPV FLANGE 0.000 B06.040.045 2RPV-THREAD-45 MCM 2201.01-1 NDE-640 UT CS 0.000 40387 THREADS IN RPV FLANGE 0.000 B06.040.046 2RPV-THREAD-46 MCM 2201.01-1 NDE-640 UT CS 0.000 40387 THREADS IN RPV FLANGE 0.000 806.040.047 2RPV-THREAD-47 MCM 2201.01-1 NDE-640 UT CS 0.000 40387 THREADS IN RPV FLANGE 0.000 806.040.048 2RPV-THREAD-48 MCM 2201.01-1 NDE-640 UT CS 0.000 40387 THREADS IN RPV FLANGE 0.000 806.040.049 2RPV-THREAD-49 MCM 2201.01-1 NDE-640 UT CS 0.000 40387 THREADS IN RPV FLANGE 7
0.000 B06.040.050 2RPV-THREAD-50 MCM 2201.01-1 NDE-640 UT CS 0.000 40387 THREADS IN RPV FLANGE 0.000
O O
O CATEGORY B-G-1. Pressure RetaininQ OUAUTY A SURANCE C t# CAL SERVICES Boltina. Greater than 2" in Diameter Inservice inspection Database Management System Plan Report Reactor Vessel McGuire Unit 2 Page 19 inservice inspection Plan for interval 2 Outage 1 04/05/1995 ITEM NUMBER ID NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENTS B06.040.051 2RPV-THREAD-51 MCM 2201.01 1 NDE-640 UT CS 0.000 40387 THREADS IN RPV FLANGE 0.000 B06.040.052 2RPV-THREAD-52 MCM 2201.01-1 NDE-640 UT CS 0.000 40387 THREADS IN RPV FL ANGE 0.000 806.040.053 2RPV-THREAD-53 MCM 2201.01-1 NDE-640 UT CS 0.000 40387 THREADS IN RPV FLANGE 0.000 B06.040.054 2RPV-THREAO-54 MCM 2201.01-1 NDE-640 UT CS 0.000 40387 THREADS IN HPV FLANGE 0.000 Total 806.040 items:
54
CATEGORY B-G-1. Pressure Retainina OUAUTY ASSURAN E C t#CALSERVICES Boltina. Greater than 2" In Diameter inservice inspection Database Management System Plan Report McGuire Unit 2 Page 20 Inservice inspection Plan for Interval 2 Outage 1 04/05/1995 ITr_M NUMBER ID NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENTS
- + Closure Washers, Bushings -
806.050.001 2RPV-664-33-01 MCM 2201.01-21 OAL-13 VT-1 CS 10.560 CLOSURE WASHERS RDM 30738-1544 0 000 806.050.002 2RPV-664-33-02 MCM 2201.01-21 OAL-13 VT-1 CS 10.560 CLOSURE WASHERS RDM 30738-1544 0.000 806.050.003 2RPV-664-3343 MCM 2201.01-21 OAL-13 VT-1 CS 10.560 CLOSURE WASHERS RDM 30738-1544 0.000 B06.050.004 2RPV-664-33-04 MCM 2201.01-21 OAL-13 VT-1 CS 10.560 CLOSURE WASHERS RDM 30738-1544 0.000 806.050 005 2RPV-664-3345 MCM 2201.01-21 OAL-13 VT-1 CS 10.560 CLOSURE WASHERS RDM 30738-1544 0.000 806.050.006 2RPV-664-33-06 MCM 2201.01-21 OAL-13 VT-1 CS 10.560 CLOSURE WASHERS RDM 30738-1544 0.000 806.0'.C.007 2RPV-664-33-07 MCM 2201.01-21 OAL-13 VT-1 CS 10.560 CLOSURE WASHERS RDM 30738-1544 0.000 B06.050.008 2RPV-664-33-08 MCM 2201.01-21 OAL-13 VT-1 CS 10.560 CLOSURE WASHERS RDM 30738-1544 0.000 806.050.009 2RPV-664-33-09 MCM 2201.01-21 OAL-13 VT-1 CS~
10.560 CLOSURE WASHERS RDM 30738-1544 0.000 Total 806.050 ftoms:
9 Total Category B-G-1 Items:
90
O O
O CATEGORY B-G-2. Pressure RetalM DUKE POWER COMPANY QUAUTY ASSURANCE TECHNICAL SERVICES Boltina. 2" And Less in Diameter Inservice inspection Database Management System Plan Report EPumps McGuire Unit 2 Page 21 Inservice inspection Plan for Interval 2 Outage 1 M/05/m5 ITEM NUMBER ID NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/iHK CAL BLOCKS COMMENTS Bolts, Studs, and Nuts -..
807.060.004 2RCP-2D-S MCM 1201.01-120 O AL-13 VT-1 NA 2.000 RCP #1 SEAL GLAND BOLTING 12 BOLTS PC 15 8.000 LIMITED 10 ONLY ONE PER INTERVAL B07.060.008 2RCP-2D-H
- LCM 1201.01-120 QAL-13 VT-1 NA 1.000 RCP #2 SEAL HOUSING BOLTING 12 BOLTS PC 66 3.250 LIMITED TO ONLY ONE PER INTERVAL Total 907.060 Itoms:
2
O O
O CATEGORY B-G-2. Presnre Retainina K
COMPANY OUALITY A Bottina. 2" And Less en Diameter in tvic in.p.ction D.tabas. Men g.m nt system Plan R. port McGuir. Unit 2 Pag. 22 l
3 Inservice inspection Plan for Interval 2 Outage 1
"'05' *5 l ITEM NUMBER ID NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENIS Bolts, Studs, and Nuts -
B07.070.004 2NC-27C MCF1-2NC15 OAL-13 VT-1 SS 0.000 4" VALVE MC 2553-2.0 0000 MCM 1205.06-001-01 807.070.030 2ND-1 B MCF1-2ND1 OAL-13 VT-1 SS 0.075 14" VALVE MC 2561-1.0 0.000 MCM 1205.60-010-01 Total 907.070 item.:
2 Total Category B-G-2 Item.:
4 i
i 1
l l
O O
O CATEGORY B-H. Intearal Attachments for oUAUTY A IRAN E CHt# CAL SERVICES VOSSelS Inservice inspection Database Management System Plan Report Pressurizer McGuire Unit 2 Page 23 Inservice inspection Plan for Interval 2 Outage 1 04/05/1995 ITEM NUMBER ID NUMBER ISO!DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENTS
~ integrally Welded Attachments -
B08.020.002 2PZR W13A MCM 2201.01-16 NDE-25 MT CS 4.000 PZR SElSMIC LUG TO SHELL EDSK-3794388 4.000 Y Z OUADRANT LUG to SHELL B08.C20.003 2PZR-W13B MCM 2201.01-16 NDE-25 MT CS 4 000 PZR SEISMIC LUG TO SHELL EDSK-379438B 4.000 X.Y OUADRANT LUG to SHELL B08.020.004 2PZR-W13C MCM 2201.01-16 NDE-25 MT CS 4.000 PZR SEISMIC LUG TO SHELL EDSK-3794388 4.000 W-X OUADRANT LUG to SHELL B08.020.005 2PZR-W13D MCM 2201.01-16 NDE-25 MT CS 4.000 PZR SElsMIC LUG TO SHELL EDSK-3794388 4 000 W-Z QUADRANT LUG to SHELL Total 808.020 items:
4 Total Category B-H ltems:
4
O O
O CATEGORY B-J. Pressure Retainina Welds OUALITY AYURANCE CHNICAL SERVICES in Pipina in.orvice in.pection o.ien..e Menegement Sy.iem Plan Report Larner McGuire Unit 2 Page 24 M
Inservice Inspection Plan for Interval 2 Outage 1 04/Osims ITEM NUMBER ID NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENTS
-CircumferentialWelds -
B09.011.001 2NC2F-1-4 BWNC-2(A LOOP)
NDE-610 UT SS 31.000 50214 Circumferential MCM 2201.01-18/2 3.000 Elbow (Loop 1) to Pipe (Loop 1) 809.011.001 A 2NC2F-1-4 BWNC-2(A LOOP)
NDE-35 PT SS 31.000 Circumferential MCM 2201.01-18/2 3.000 i
^
Elbow (Loop 1) to Pipe (Loop 1) 4 B09.011.008 2NC2F-2-7 BWNC-2(B LOOP)
NDE-610 UT SS 27.500 50214 Circumferential MCM 2201.01-18/6 2.000 Nozzle (Loop 2) to Ppe (Loop 2) 809.011.008A 2NC2F-2-7 BWNC-2(B LOOP)
NDE-35 PT SS 27.500 Circumferential MCM 2201.01-185 2.000 Nozzle (Loop 2) to Ppe (Loop 2)
B09.011.019 2NC2FW53-1 MCF1-2NC53 NDE-600 UT SS 6.000 50211 Circumferential 160 0.719 Stress weld Ebow to Flange 809.011.019A 2NC2FW53-1 MCFI-2NC53 NDE-35 PT SS 6.000 Circumferential 160 0.719
)
Stress wesd Ebow to Flange i
i B09.011.020 2NC2FW53-2 MCFi-2NC53 NDE-600 UT SS 6.000 50211
]
Circumferential 160 0.719 Stress weld Ppe to Elbow B09.011.020A 2NC2FW53-2 MCFI-2NC53 NDE-35 PT SS 6.000 Circumferential 160 0.719 Stress weld Pipe to Elbow B09.011.021 2NC2FW53-7 MCFI-2NC53 NDE-600 UT SS 6.000 50211 Circumferential 160 0.719 Stress weld Elbow to Pipe 809.011.021 A 2NC2FW53-7 MCF1-2NC53 NDE-35 PT SS 6.000 Circumferential 160 0.719 Stress weld Elbow to Pipe
O O
O CATEGORY B-J. Pressure Retainina Welds QUALITY A SURANCE CHNICAL SERVICES in Piping in.orvice inepection oeieneee Menege,nent Syeiem Plan Report r r McGuire Unit 2 Page 25 Inservice Inspection Plan for interval 2 Outage 1 04'95" 995 ITEM NUMBER 10 NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENTS B09.011.022 2NC2FW53-8 MCFI-2NC53 NDE-600 UT SS 6.000 50211 Cucumferential 160 0.719 Stress weld Poe to Elbow B09.011.022A 2NC2FW53-8 MCFl-2NC53 NDE-35 PT SS 6.000 Cacumferential 160 0.719 Stress weld Ppe to Elbow B09.011.023 2NC2FW53-9 MCF1-2NC53 NDE-600 UT SS 6.000 50211 Circumferential 160 0.719 Stress weld Elbow to Pipe B09.011.023A 2NC2FW53-9 MCFI-2NC53 NDE-35 PT SS 6.000 Circumferential 160 0.719 Stress weld Elbow to Pipe B09 011.024 2NC2FW53-10 MCF1-2NC53 NDE-600 UT SS 6.000 50211 Cucumferential 160 0.719 Stress weld Poe to Elbow B09.011.024 A 2NC2FW53-10 MCFI-2NC53 NDE-35 PT SS 6.000 Circumferential 160 0.719 Stress weld Poe to Elbow B09.011.027 2NC2FW53-16 MCF1-2NC53 NDE-600 UT SS 6.000 50211 Circumferential MC-2552-2.0 160 0.719 Stress weld Poe to Elbow B09.011.027A 2NC2FW53-16 MCF1-2NC53 NDE-35 PT SS 6.000 Circumferential 160 0.719 Stress weld Pipe to Elbow B09.011.100 2ND2F-1 MCFI-2ND1 NDE-600 UT SS 14.000 50213 Circumferential 140 1.250 Valve (2ND18) to Pipe B09.011.100A 2ND2F-1 MCF1-2ND1 NDE-35 PT SS 14.000 Circumferential 140 1.250 Valve (2ND1B) to Pipe
~.
O O
O CATEGORY B-J. Pressure Retainina Welds QUAUTY A ANC ECHNICAL SERVICES In Pignng ineervice inepection Deiseene Menagement System Plan Report r r McGuire Unit 2 Page 26 M
Inservice inspection Plan for interval 2 Outage 1
- '05' 85 ITEM NUMBER ID NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENTS B09.011.101 2ND2F-3 MCF1-2ND1 NDE-600 UT SS 14.000 50213 Circumferential 140 1.250 Elbow to Pipe B09 011.101 A 2ND2F-3 MCF1-2ND1 NDE-35 PT SS 14.000 Circumferential 140 1.250 Elbow to Pipe B09.011.154 2N12F425 MCF1-2N112 NDE-600 UT SS 6.000 50211 Cacumferential 160 0.719 Valve (2N1176) to Elbow B09.011.154 A 2N12F425 MCF1-2 Nil 2 NDE-35 PT SS 6.000 Circumferential 160 0.719 Valve (2N1176) to Elbow B09.011.155 2N12F428 MCF1-2N112 NDE-600 UT SS 6.000 50211 Crcumferential 160 0.719 Pipe to Elbow B09.011.155A 2Nf2F428 MCF1-2N112 NDE-35 PT SS 6.000 Circumferential 160 0.719 Pipe to Elbow B09.011.156 2N12F439 MCF1-2N112 NDE-600 UT SS 6.000 50211 Circumferentiat 160 0.719 Ppe to Elbow B09.011.156A 2N12F439 MCF1-2N112 NDE-35 PT SS 6.000 Circumferential 160 0.719 Pipe to Elbow Total 809.011 Items:
28
- - - - - - - - - - - - - - - - - - - - - - - - - - - ' - - - - - - - - - - - ~ ~ ~ ~ " - - - - - - - - - - - - ' ~ - - - " - - ^ - - ~ ~ - - - - - ' ' ' ' ~ ~ ~ ' ' ~ ~ ~ ~ ~ ~ ~
O O
O CATEGORY B-J. Pressure Retainina Welds QUAT.lTY A SURANCE ECHNICAL SERVICES in Piping ins.,vice inspection ostabas unn.g.m.ni System Plan Report 4
McGuire Unit 2 Page 27 E
Inservice inspection Plan for interval 2 Outage 1 M/05/1995 ITEM NUMBER ID NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENTS
=~. Circumferential Welds ~~
B09.021.003 2NC2FW26-1 MCF1-2NC26 NDE-35 PT SS 3.000 Circumferential 160 0.438 Stress weld Elbow to Nozzle 809.021.004 2NC2FW26-3 MCF1-2NC26 NDE-35 PT SS 3.000 Circumferential Pipe to Elbow 160 0.438 Stress weld B09.021.005 2NC2FW26-5 MCFI-2NC26 NDE-35 PT SS 3.000 Circumferential 160 0.438 Stress weld Valve (2NV15) to Ppe B09.021006 2NC2FW26-8 MCFI-2NC26 NDE-35 PT SS 3.000 Circumferential 160 0.438 Stress weld Ppe to Pipe Total BO9.021 Items:
4 9
e
_ _ _ _. _ _. _ _ _ ~
O O
O CATEGORY B-J. Pressure Retainina Welds K POW MPANY OUALITY ASSURAgE EC
,L SERVICES in Piping in.orvice inspection Database Management System Plan Report Branch Ploe Connection Welds McGuire Unit 2 Page 28 04/05/m5 inservice inspection Plan for Interval 2 Outage 1 ITEM NUMBER 10 NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENTS
- NPS 4 or Larger ****
B09.031.002 2NC22-WN4 MCFI-2NC22 NDE-610 UT SS 10.000 50214 EXAM TO BE DONE FROM MC PIPE SIDE Branch MCM 2201.01-18/9 1.000 Ppe (P1) to Nozzle (PC. B)
B09.031.002A 2NC22-WN4 MCFI-2NC22 NDE-35 PT SS 10.000 Branch MCM 2201.01-18!9 1.000
~
Pipe (P1) to Nozzle (PC. B)
B09.031.003 2NC22-WN8 MCF1-2NC22 NDE-610 UT SS 6.000 50214 EXAM TO BE DONE FROM MC PIPE SIDE Branch MCM 2201.01-18/4 0.719 Ppe (P1) to Nozzle (PC. C)
B09.031.003A 2NC22-WN8 MCF1-2NC22 NDE-35 PT SS 6.000 Branch 0.719 Ppe (P1) to Nozzle (PC. C)
Total B09.031 Items:
4
.. Less Than NPS 4 -
B09.032.001 2NC26-WN6A MCF1-2NC26 NDE-35 PT SS 3.000 Branch 0.438 Ppe (P1) to Nozzle (PC. E)
B09.032.002 2NC47-WN7A MCF1-2NC47 NDE-35 PT SS 3.000 Branch 0.438 Ppe (P2) to Nozzle (PC. C) 809.032.003 2NC39-WN2 MCF1-2NC39 NDE-35 PT SS 2.000 Branch 0.344 Pipe (P1) to PC. G - Weld boss C39.032.004 2NC47-WN8 MCFI-2NC47 NDE-35 PT SS 2.000 Branch 0.344 Ppe (P2) to PC. D - Weld boss B09.032.005 2NC39-WN10 MCFI-2NC39 NDE-35 PT SS
- .500 Branch 0.281 Ppe (P1) to PC. H - Weld boss
O O
O CATEGORY B-J. Pressure Retainina Welds OUALITY A S ANCE EC NICAL SERVICES In Pipina inservice inspection o.i.n.
Men gernent System Plan Report Branch Pine Connection Welds McGuire Unit 2 Page 29 Inservice inspection Plan for Interval 2 Outage 1
"'05'
- 5 ITEM NUMBER 10 NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENTS B09.032.006 2NC2FW53-3 MCF1-2NC53 NDE-35 PT SS 1.500 Branch 160 0 281 Stress weld Ppe to Sweepolet 809.032.007 2NC2FW53-20 MCF1-2NC53 NDE-35 PT SS 1.500 Branch 160 0.281 Stress weld Ppe to Sweepolet 809.032.008 2NC2FW53-32 MCF1-2NC53 NDE-35 PT SS 1.500 Branch 160 0.281 Stress weld Poe to Sweepolet Tot.1 B09.032 Items:
8 I
4
~
O O
O CATEGORY B-J. Pressure Retainina Welds QUAUTY ASSU E ECHNICALSERVICES In N9IR9 Inservice inspection Database Management System Plan Report Socket Welds McGuire Unit 2 Page 30 Inservice inspection Plan for interval 2 Outage 1 04/05/1995 ITEM NUMBER ID NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENTS B09.040.008 2NC2FW47-13 MCF1-2NC47 NDE-35 PT SS 2.000 Socket 160/6000 0.344 Ppe to Elbow B09.040.009 2NC2FW47-14 MCF1-2NC47 NDE-35 PT SS 2.000 Socket
^
Elbow to Pipe 160/6000 0.344 809.040.010 2NC2FW47-15 MCFI-2NC47 NDE-35 PT SS 2.000 Socket 160 0.344 Ppe to Valve (2NC4)
B09.040 011 2NC2FW4814 MCF1-2NC48 NDE-35 PT SS 2.000 Socket 160 0.344 Ppe to Valve (2NC94)
B09.040 012 2NC2FW48-17 MCF1-2NC48 NDE-35 PT SS 2.000 Socket 160 0.344 Tee to Reducer B09.040.013 2NC2FW48-19 MCFI-2NC48 NDE-35 PT SS 2.000 Socket 160 0.344 Poe to Elbow B09.040.014 2NC2FW48-21 MCF1-2NC48 NDE-35 PT SS 2.000 Socket 160 0.344 Ppe to Valve (2NC95)
B09.040.016 2NC2FW39-2 MCFI-2NC39 NDE-35 PT SS 1.500 Socket 160 0.281 Stress weld Valve (2NI-15) to Ppe 809.040.065 2N12FW26-21 MCFI-2N126 NDE-35 PT SS 2.000 Socket 160/6000 0.344 WB to Pipe B09.040.066 2N12FW57-1 MCF1-2N!57 NDE-35 PT SS 2.000 Socket
- 20 0.344 Valve (2N1169) to Pipe
O O
O i
CATEGORY B-J. Pressure Retainina Welds QUALITY AS RANCE EC NICALSERVICES In Piping in.ervice inspection o. tab.e Man.9ement System Plan ReporI w
McGuire Unit 2 Page 31 Inservice Inspection Plan for interval 2 Outage 1 04/05/1995,
ITEM NUMBER ID NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENTS B09.040.067 2N12FW57-7 MCFI-2N157 NDE-35 PT SS 2.000 Socket 160/6000 0.344 Ppe to Elbow B09.040.109 2NV2FW102-10 MCF1-2NV102 NDE-35 PT SS 2.000 Socket 160/6000 0.344 Stress weld Ppe to Elbow B09.040.110 2NV2FW102-11 MCFI-2NV102 NDE-35 PT SS 2.000 Socket 160/6000 0.344 Stress weld Elbow to Pipe B09.040.111 2NV2FW102-18 MCF1-2NV102 NDE-35 PT SS 2.000 Socket 160/6000 0.344 Stress weld Ppe to Elbow B09.040.120 2NV2FW255-15 MCF1-2NV255 NDE-35 PT SS 2.000 Socket 160 0.344 Valve (2NV63) to Ppe B09.040.121 2NV2FW255-4 MCFi-2NV255 NDE-35 PT SS 2.000 Socket 160 0.344 Ppe to Valve (2NV812) i i
B09.040.123 2NV2FW264-18 MCF1-2NV264 NDE-35 PT SS 2.000 Socket 160 0.344 Pipe to Valve (2NV811)
B09.040.125 2NV2FW275-20 MCFl-2NV275 NDE-35 PT SS 2.000 Socket 1604000 0.344 Tee to Reducing insert 809.040.127 2NV2FW282-25 MCFI-2NV282 NDE-35 PT SS 2.000 Socket 160 0.344 Valve (2NV79) to Pipe 809.040.128 2NV2FW282-4 MCF1-2NV282 NDE-35 PT SS 2.000 Socket 160 0.344 Poe to Valve (2NV813)
Total B09.040 Itoms:
20
- -. _ -.. - - -..~
O O
O CATEGORY B-J. Pressure Retainina Welds OUAUTY A RANCE CHNICAL SERVICES in Ptpina inservice inspection ostabe men.g.m.ni sy iem Plan Report Socket Welds McGuire Unit 2 Page 32 m/os/ms Inservice Inspection Plan for Interval 2 Outage 1 ITEM NUMBER ID NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENTS Tatal Category B-J Items:
64 O
s
O O
O CATEGORY B-M-2. Valve Bodies DUKE POWER COMPANY OUALITY ASSURANCETECHNICAL SERVICES Inservice inspection Database Managestwnt System Plan Repori Valves McGuire Unit 2 Page 33 04'05'1995 Inservice laspection Plan for interval 2 Outage 1 ITEM NUMBER ID NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENTS
- Valve Body, Exceeding NPS 4 -
B12.050.004G 2Ni-93 MCF1-2N119 OAL-14 VT-3 SS 10.000 10' WALWORTH CHECK VALVE MC 2562-2.1 0 000 (INSPECT ONLY ONE 10' WALWORIH CHECK val VL MCM 1205.00-0009-001 PER INTERVAL)
B12.050.007D 2Ni-160 MCFI-2N1116 OAL-14 VT-3 SS 6.000 6' WALWORTH CHECK VALVE MC 2562-3.0 0.000 (INSPECT ONLY ONE 6" WALWORTH CHECK VALVE MCM 1205.0'O-0005-001 PER INTERVAL)
Total C12.05011 ems:
2 Total Category 8-M-2 items:
2 i
9
)
O O
O CATEGORY B-N-1. Interior of Reactor DUKE POWER COMPANY OUALITY ASSURANCE TECHNICAL SERVICES Vessel inservice inspection Database Management System Plan Report Reactor Vessel McGuire Unit 2 Page 34 i
inservice Inspection Plan for Interval 2 Outage 1 04'05'l
- Vessel Interior..
B13.010.001 2RPV-INTERIOR MCM 2201.01-21 OAL-14 VT-3 SS 0.000 AREA ABOVE AND BELOW CORE MADE 0.000 ACCESSIBLE OURING REFUELING Total C13.010 Ltems:
1 Total Category B-N-1 Items:
1
. m
O O
O CATEGORY B-O. Pressuye Retainina Welds OUALITY A SURANCE EC NICAL SERVICES in Control Rod Housings inservice inspection oei base Management system Plan Report Reactor Vesseg McGuire Unit 2 Page 35 Inservice inspection Plan for Interval 2 Outage 1 04/05/1995 ITEM NUMBER ID NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENTS
B14.010.017 2RPV-CRDM 71 MCM 2201.01-21 NDE-35 PT SS/Inconel 4.000 CRD HOUSING WELD (PERIPHERAL)
MCM 2201.01-20 0.642 Total C14.010 Itoms:
1 Total Category B-O ltems:
1
~
i l
_. _ _ _ _. _ = _.___ _ _.._
O O
O DUKE PuWER COMPANY CAYMORY "
QUALITY ASSURANCE TECHNICAL SERVICES Inservice inspection Detsbees Managemsni System Plan Report McGuire Unit 2 Page 36 N1M inservice inspection Plan for interval 2 Outage 1 ITEM NUMBER ID NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENTS B16.020.001 2SGA-TUBES ET NA 0.000 NFO ON SG TUBE EXAMS CAN BE ACQUIRED 0.000 FROM THE DIVERSIFIED SERVICES GROUP OF THE ELEC. SYSTEM DEPT. OF DPC B16.020.002 2SGB-TUBES ET NA 0.000 NFO ON SG TUBE EXAMS CAN BE ACQUIRED 0.000 FROM THE DIVERSIFIED SERVICES GROUP OF THE ELEC. SYSTEM DEPT. OF DPC B16.020.003 2SGC-TUBES ET NA 0.000 NFO ON SG TUBE EXAMS CAN BE ACQUIRED 0.000 FROM THE DIVERSFIED SERVICES GROUP OF THE ELEC. SYSTEM DEPT. OF DPC B16.020.004
,CoGD-TUBES ET NA 0.000 NFO ON SG TUBE EXAMS CAN BE ACOUIRED 0.000 FROM THE DIVERSFIED SERVICES GROUP OF THE ELEC. SYSTEM DEPT. OF DPC Total 016.020 items:
4 Total Category items:
4 1
O O
O
- fl TEGOhY C-A. Pressure Retainina Welds QUALITY ASSURANCE ECHNICALSERVICES 78 Pressure Vessels inservic. inspection pet.b.
Men.g.m.no system Plan R. port Shell Circumferential Welds McGuit. Unit 2 Page 37 Inservice inspection Plan for interval 2 Outage 1 04ms/ms ITEM NUMBER ID NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENTS C01.010.00*
2SGA-03-04A MCM 2201.01-011 NDE 620 UT CS 0.000 50366 STEAM GENERATOR 2A STUB BARREL 10 LOWER Cucumferential MCM 1201.01-480 NDE-640 3.310 SHELL STUB BARREL-PC.3 to LOWER SHEl_L PC.4A (PC.3 TO PC.4A)
C01.010.070 2SWHX-BSH-BFLG MCM 1201.06-9 NDE-35 PT SS 14.000 50421 SEAL WATER HEAT EXCHANGER BONNET SHElL Circumferential BONNET SHELL to BONNET FLANGE IMPLEMENTATION OF CODE CASE N4351 0.187 TO BONNET FLG.
Totes CJ1.010 items:
2 5
ir
O O
O CATEGORY C-A. Pressure Retainina Welds OUALITY A SURANCE ECHNICAL SERVICES If1 Pressure Vessels inservice insp.ction D.i.b.
M.n.9.m.nt System Plan Report Head Circumferential Welds McGuir.18 nit 2 Page 38
"#05'*S Inservice inspection Plan for Interval 2 Outage 1 siEM NUMBER ID NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENTS C01.020.090 2RCPSS-SH-3 MCM 1201.04 272 NDE-630 UT SS 12.000 50313 RECIPROCAIING CHG PMP SUCTION SI ABilI/EH Circumferential MC 2554-3.0 0.375 SHELL TO UPPER HEAD SHELL to HEAD C01.020.091 2RCPSS-SH-2 MCM 1201.04-272 NDE-630 UT SS 12.000 50313 RECIPROCATING CHG. PMP. SUCTION STABILIZER Circumferential MC 2554-3.0 0.375 Si1 ELL TO LOWER HEAD SHELL to HEAD Total C01.020 Items:
2
O O
O CATEGORY C-A. Pressure Retainina Welds in Pressure Vessels QUALITY ASSURANCE EC NICAL SERVICES inservice inspection Database unnagement system Plan Report Tubesheet-to-Shell Weld McGuire Unit 2 Page 39 Insesvice inspection Plan for Interval 2 Outage 1 04/05/1995 ITEM NUMBER ID NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENTS C01.030 001 2SGA-02-03 MCM 1201.01-480 NDE-620 UT CS 0000 50366 STEAM GENERATOR 2A TUBE SHEEI TO SIUH Circumferential MCM 2201.01-011 NDE-640 3.310 BARREL PC.2 TO PC.3 TUBE SHEET to STUB BARREL Tot:1 C01.030 ftoms:
1 Total Category C-A Items:
5
~
i i
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ' - - ~ ' - - - - - - - - - - - ' - - - - - - - - - - - - - - - - -
~ ~ - - - ' - ' - - - - - - - - ' -
O O
j kJ G
CATEGORY C-B. Pressure Retainina Nozzi; QUAUTY ASSURAN E EC NICAL SERVICES Welds in Vessels inservic. insp.ction o.teben. unn g. ment System Plan Report Nozzles in Vessels s 1/2 in. Nominal Thk.h.tif12 McGuir. Unit 2 Page 40 Inservice inspection Plan for Interval 2 Outage 1 04/05/1995
, lie y VMBER ID NUMBER ISO /DWG NUMBERS -
PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENTS y Nozzle-to-Shell(or Head) Weld -
CO2.011.001 2RCPSS-INLET MCM 1201.04-272/1 NDE-35 PT SS 4.000 RECEIP. CHARGING PUMP STABLIZER SUCTION Circumferential MC 2554-3.0 0.3 75 INLET NOZZLE TO SHELL Nozzle to SHELL CO2.011.002 2RCPSS-OUTLET MGM 1201.04-272/1 NDE-35 PT SS 4.000 RECIP. CHARGING PUMP STABLIZER DISCHARGf Circumferential MC 2554-3.0 0.375 OUTLET NOZZLE TO SHELL Nozzleto SHELL Total CO2.011 Items:
2 m
O O
O CATEGORY C-B. Pressure Retainina Nozzle OUALITY A SURANCE CHfeCAL SERVICES Welds in Vessels in rvic. in.p.ction D.i.b.
Men.g.m.nt System Plan Repori Nozzles Without Reinforcina Plate in Va==als >
McGuire Unit 2 Page 41 1/2 in, Nom Thickness inservice inspection Plan for interval 2 Outage 1 04'U5'l " S ITEM NUMBER ID NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENTS
- Nonie-to Shell(or Head) Weld -
CO2.021.002 2SGA-SB-02 MCM 2201.01-11 NDE 620 UT CS 16.000 50366 STEAM GENERATOR 2A FEEDWATER NOZltE 10 Circumferentia!
MCM 1201.01-480 NDE-640 3 250 STUB BARREL EDSK-3511068 Nozzle to STUB BARREL CO2.021.002A 2SGA-SB-02 MCM 2201.01-11 NDE-25 MT CS 16.000 STEAM GENERATOR 2A FEEDWATER NOZZLE TO Circumferential MCM 1201.01-480 3.250 STUB BARREL EDSK-3511068 Nozzle to STUB BARREL Total CO2.021 Items:
2
-. Nonle inside Radius Section -
CO2.022.002 2SGA-SB-02 MCM 2201.01-11 NDE-680 UT CS 16.000 50366 STEAM GENERATOR 2A FEEDWATER NOZZLE Circumferential MCM 1201.01-480 3.250 INSIDE RADIUS EDSK-3511068 Nozzle to Shell Total CO2.02211 ems:
1 Total Category C-8 Itens:
5
O O
O CATEGORY C-C. Intearal Attachments For DUKE POWER COMPANY OUAUTY ASSURANCE TECHNICAL SERVICES Vessels. Pinina. Pumns. And Valves inservice inspection Database Management System Plan Report McGuire Unit 2 Page 42 U##U ##5 Inservice inspection Plan for Interval 2 Outage 1 ITEM NUMBER ID NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENTS
== Integrally Welded Attachments -
CO3.010.001 2RHRHX-2A-SUPP MCM 1201.06-022 NDE-35 PT CS 0.000 RHR HEAT EXCHC SUPP. 2A 28' X 52-Circumferential MCM 1201.06-048 0.750 SUPPORT to HEAT EXCil (2A)
C03.010.002 2SWHX-SUPP MCM 1201.06-009 NDE-35 PT CS 0.000 SEAL WATER HEAT EXCH. SUPP Circumferential MCM 1201.06-054 0.750 HEAT EXCH to SUPPORT Total C03.010 itoms:
2 Total Category C-C ltems:
2 O
e
.~.
.O O
O CATEGORY C-F-1. Pressure Retainina QUAUTY A E CHNICAL SERVICES Welds in Austenitic SS or High Allow Piping ineervice inepection Dei. bee. :: s:;:=.,t System Plan Report d6 "' ' "= > 3/8 in Nominal Wall TiR' = ss for McGuire Unit 2 Page 43 Je > NP5 4 04'05'
- 5 Inservice Inspection Plan for intectat 2 Outage 1 ITEM NUMBER ID NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENIS
- Circumferential Weld -
C05.011.004 2ND2FW17-22 MCF1-2ND17 NDE-600 UT SS 14.000 50432 To be done with item number COS 012 034 Cucumferential 40 0.438 Term end Nozzle (RHRHX) to Reducer C05.011.004 A 2ND2FW17-22 MCF1-2ND17 NDE-35 PT SS 14.000 To be done with item number C05.012.034 A Circumferential Nozzle (RHRHX) to Reducer 40 0.438 C05.011.005 2ND2FW20-13 MCF1-2NO20 NDE 600 UT SS 14.000 50432 To be done with item number C05.012.035 Circumferential 40 0.438 Term end Reducer to Nozzle (RHRHX)
C05.011.005A 2ND2FW20-13 MCFI-2ND20 NDE-35 PT SS 14.000 To be done with item number C05.012.035A Cucumferential 40 0.438 Term end Reducer to Nozzle (RHRHX)
C05.011.012 2ND2F-201 MCFI-2ND10 NDE-600 UT SS 12.000 50313 To be done with item number C05.012.005 Cucumferential STD 0.375 Elbow to Pipe C05.011.012A 2ND2F-201 MCF1-2ND10 NDE-35 PT SS 12.000 To be done with item number C05.012.005A Circumferential STD 0.375 Elbow to Pipe C05.011.013 2NDP106-1 MCFI-2ND10 NDE-600 UT SS 12.000 50313 To be done with item number C05?O12.006 Circumferential STD 0.375 Pipe to Elbow C05.011.013A 2NDP106-1 MCFI-2ND10 NDE-35 PT SS 12.000 To be done with item number C05.012.006A Circumferential STD 0.375 Pape to Elbow C05.011.037 2ND2FW16-14 MCFI-2ND16 NDE-600 UT SS 12.000 50313 To be done with item number C05.012.032 Circumferential STD 0.375 i
Pipe to Elbow C05.011.037A 2ND2FW16-14 MCFI-2ND16 NDE-35 PT SS 12.000 To be done with item number C05.012.032A Cucumferential STD 0.3 75 Pipe to Elbow
O O
O CATEGORY C-F-1. Pressure Retainina QUAUTY ASSURANCE C NICAL SERVICES Welds in AustenitiC SS or Hiah Allov Pinina Pinina Welds > 3/8 in. Nominal Wall Thickness for-inservice inspection Database Management System Plan Report McGuire Unit 2 Page 44 Ploina > NPS 4 Inservice inspection Plan for Interval 2 Outage 1 04'05'1095 ITEM NUMBER ID NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENTS C05.011.101 2N12F422 MCF1-2N112 NDE-600 UT SS 6.000 50211 Circumferential 160 0.719 Elbow to Pipe C05.011.101 A 2N12F422 MCF1-2N112 NDE-35 PT SS 6.000 Circumferential 160 0.719 Elbow to Pipe C05.011.105 2N12F441 MCF1-2NI14 NDE-600 UT SS 6.000 50211 Circumferential 160 0.719 Pipe to Elbow C05 011.105A 2N!2F441 MCF1-2N114 NDE-35 PT SS 6.000 Circumferential 160 0.719 Ppe to Elbow C05.011.107 2N12F448 MCF1-2N114 NDE-600 UT SS 6.000 50211 Circumferential 160 0.719 Elbow to Pipe C05.011.107A 2N12F448 MCFI-2N114 NDE-35 PT SS 6.000 Circumferential 160 0.719 Elbow to Pipe C05.011.109 2N12F450 MCFI-2N114 NDE-600 UT SS 6.000 50211 Circumferential Ppe to Valve (2N1175) 160 0.719 C05.011.109A 2N12F450 -
MCF1-2N114 NDE-35 PT SS 6.000 Circumferential 160 0.719 Pipe to Valve (2NI175)
C05.011.110 2N12F4G1 MCF1-2N115 NDE-600 UT SS 6.000 50211 Circumferential 160 0.719 Reducer to Pipe C05.011.110A 2N12F461 MCFI-2N115 NDE-35 PT SS 6.000 Circumferential 160 0.719 i
Reducer to Pipe
(
\\_)
V V
CATEGORY C-F-1. Pressure Retainina QUAUTY ASSURAN E EC CAL SERVICES Welds in Austenitic SS or Hiah Allov PIDina inservice inspection Database Management System Plan Report Piolna Welds > 3/8 in. Nominal Wali Thickness for McGuire Unit 2 Page 45 Ploina > NPS 4 Inservice inspection Plan for Interval 2 Outage 1 04/05/1995 j
ITEM NUMBER ID NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENTS C05.011.112 2N12F464 MCF1-2NB15 NDE-600 UT SS 6.000 50211 Circumferential 160 0 719 Reducer to Pepe C05.011.112A 2Nt2F464 MCF1-2N115 NDE-35 PT SS 6 000 Circumferential 160 0 719 Reducer to Pipe C05 011.113 2N!2F465 MCFI-2NI15 NDE-600 UT SS 6.000 50211 Circumferential 160 0.719 Pipe to Elbow C05.011.113A 2N!2F465 MCF1-2N115 NDE-35 PT SS 6.000 Circumferential 160 0.719 Pipe to Elbow C05.011.114 2N12F467 MCF1-2N115 NDE-600 UT SS 6.000 50211 Cucumferential 160 0.719 Pipe to Elbow C05.011.114A 2Nt2F467 MCFI-2N115 NDE-35 PT SS 6.000 Circumferential 160 0.719 Pipe to Elbow C05.011.117 2N12F470 MCF1-2NI15 NDE-600 UT SS 6.000 50211 Circumferential 160 0.719 Pipe to Valve (2N1180)
C05.011.117A 2N12F470 MCFI-2N115 NDE-35 PT SS 6.000 Circumferential 160 0.719 Pipe to Valve (2N1180)
C05.011.132 2N12F417 MCF1-2N112 NDE-600 UT SS 8.000 50210 Circumferential 160 0.906 Elbow to Pipe C05.011.132A 2N12F417 MCF1-2N112 NDE-35 PT SS 8.000 i
Circumferential 160 0.906 Elbow to Pipe
O O
O.
CATEGORY C-F-1. Pressure Retaining QUALITY ASSURANCE EC NICAL SERVICES Welds in Austenitic SS or Hiah Allov Pinina inservice inspection Database Management System Plan Report Ploina "!;Ms 2 3/8 in. Neininal Wall Thickness for McGuire Unit 2 Page 46 PIDina > NPS 4 Inservice inspection Plan for Interval 2 Outage 1 04'US# *5 ITEM NUMBER ID NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENTS C05.011.133 2N12F420 MCF1-2N112 NDE-600 UT SS 8.000 50210 Circumferential 160 0.906 Ppe to Tee C05.011.133A 2NI2F420 MCF1-2NI12 NDE-35 PT SS 8.000 Circumferential 160 0.906 Ppe to Tee C05.011.134 2Nt2F457 MCFl-2N112 NDE-600 UT SS 8.000 50210 Circumferential 160 0.906 Tee to Reducer C05.011.134A 2N12F457 MCFI-2N112 NDE-35 PT SS 8.000 Circumferential 160 0.906 Tee to Reducer C05.011.140 2N12FW111-1 MCF1-2N1111 NDE-600 UT SS 12.000 50219 Circumferential 140 1.125 Valve (2N11838) to Poe C05.011.140A 2NI2FW111-1 MCFI-2NI111 NDE-35 PT SS 12.000 Circumferential 140 1.125 Valve (2N11838) to Pipe Total C05.011 Itoms:
36
+ -+ Longitudinal Weld - +
C05.012.005 2ND2F-201L MCFI-2ND10 NDE-600 UT SS 12.000 50313 To be done with item number C05.011.012 Longitudinal STD 0.375 Elbow to Pipe C05.012.005A 2ND2F-201L MCFI-2ND10 NDE-35 PT SS 12.000 To be done with item number C05.011.012A Longitudinal STD 0.375 Elbow to Pipe C05.012.006 2NDP106-1L MCFI-2ND10 NDE-600 UT SS 12.000 50313 To be done with item number C05.011.013 Longitudinal STD 0.375 Ppe to Elbow
O O
O CATEGORY C-F-1. Pressure Retainin0 QUALITY A SURANCE CHNICAL SERVICES Welds in Austenitic SS or Hiah Allov PininQ inservice inspection Database Management System Plan Report In. Nominal Wall Thickness for McGuire Unit 2 Page 47 Pipina > NPS 4 inservice inspection Plan for Interval 2 Outage 1 04/05'1 M 5 ITEM NUMBER ID NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENTS C05.012.006A 2NDP106-1L MCF1-2ND10 NDE-35 PT SS 12.000 To be done with item number COS 011.013A Longitudinal STD 0.375 Papa to Elbow C05.012.032 2ND2FW16-14L MCFi-2ND16 NDE-600 UT SS 12.000 50313 To be done with item number C05.011.037 Longitudinal STD 0.375 Pipe to Eibow C05.012.032A 2ND2FW16'-14L MCFI-2ND16 NDE-35 PT SS 12.000 To be done with item number C05.011.037A Longitudinal STD 0.375 Pipe to Elbow C05.012.034 2ND2FW17-22L MCF1-2ND17 NDE-600 UT SS 14.000 50432 To be done with item number C05.011004 Longitudinal 40 0.438 Term end Nozzle (RHRHX) to Reducer C05.012.034A 2ND2FW17-22L MCF1-2ND17 NDE-35 PT SS 14.000 To be done with item number C05.011.004A Longitudinal 40 0.438 Nozzie (RHRHX) to Reducer C05.012.035 2ND2FW20-13L MCF1-2ND20 NDE-600 UT SS 14.000 50432 To be done with item number C05.011.005 Longitudinal 40 0.438 Term end Reducer to Nozzle (RHRHX)
C05.012.035A 2NO2FW20-13L MCF1-2ND20 NDE-35 PT SS 14.000 To be done with item number C05.011.005A Longitudinal 40 0.438 Term end Reducer to Nozzle (RHRHX)
Total C05.012 Itoms:
10
n O,s (q
U CATEGORY C-F-1. Pressure RetaininQ POW "
P^"
QUAUTY gE ECHNICALSERVICES Welds in Austenitic SS or Hioh Allow Pin.inQ inservice inspection Database Management System Plan Report PbMG "JJ;M5 > 1/5 in. Ne.T. Wall For PirAns >
McGuire Unit 2 Page 48 04/05/1995
_NPS 2 And s NPS 4 Inservice inspection Plan for interval 2 Outage 1 ITEM NUMBER 10 NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENTS
- Circumferential Weld -
C05.021.001 2N12FW108-8 MCF1-2N1108 NDE-600 UT SS 2.000 50217 Circumferential 160 0.344 Reducer to Ptpe C05.021.001 A 2N12FW108-8 MCFI-2N1108 NDE-35 PT SS 2.000 Circumferential Reducer to Pipe 160 0.344 C05.021.007 2N12F519 MCFI-2N117 NDE-600 UT SS 4.000 50275 Circumferential 160 0.531 Elbow to Pipe C05.021007A 2NI2F519 MCFI-2N117 NDE-35 PT SS 4.000 Circumferential 160 0.531 Elbow to Pipe C05.021.013 2N12FW25-17 MCF1-2N125 NDE-600 UT SS 4.000 50275 Circumferential 160 0.531 Pipe to Tee C05.021.013A 2N12FW25-17 MCF1-2N125 NDE-35 PT SS 4.000 Circumferential 160 0.531 Pipe to Tee C05.021.019 2 NIP 18-1 MCFl:2Nt2 NDE-600 UT SS 4.000 50436 Ch comferential 80 0.337 Elbow to Pipe C05.021.019A 2 NIP 18-1 MCF1-2N12 NDE-35 PT SS 4.000 Circurnferential 80 0.337 Elbow to Pipe C05.021.053 2NV2FW178-79 MCFI-2NV178 NDE-600 UT SS 3.000 50437 To be done with item Number CG5.022.002 Circumferential
.40 0.216 Tee to Pipe a
C05.021.053A 2NV2FW178-79 MCFI-2NV178 NDE-35 PT SS 3.000' To be done with item Number C05.022.002A Circumferential 40 0.216 Tee to Pipe
O 0:
O CATEGORY C-F-1. Pressure Retainina oUALITY ASSURANCE EC NICAL SERVICES Welds in Austenitic SS or Hioh AlloV Pinina inservice inspection Database Management System Plan Report INPS 2 And 5 NPS 4 sacry McGuire Unit 2 Page 49 Inservice inspection Plan for Interval 2 Outage 1 04'05" 995 ITEM NUMBER 10 NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENTS C05.021.059 2NV2F-23 MCF1-2NV1 NDE-600 UT SS 3.000 50225 Circumferential 160 0.436 Pipe to Valve (2NV235)
C05.021.059A 2NV2F-23 MCF1-2NV1 NDE-35 PT SS 3.000 Circumferential 160 0 438 Pipe to V*a '0NV235)
C05.021.065 2NV2FW150-31 MCF1-2NV150 NDE 600 UT SS 3.000 50225 Circumferential 160 0.438 Elbow to Pipe C05.021.065A 2NV2FW150-31 MCF1-2NV150 NDE-35 PT SS 3.000 Circumferential 160 0.438 Elbow to Pipe C05 021.071 2NV2FW26-20 MCF1-2NV26 NDE-600 UT SS 3.000 50225 Circumferential 160 0.438 Poe to Valve (2NV12)
C05.021.071 A 2NV2FW26-20 MCF1-2NV26 NDE-35 PT SS 3.003 Circumferential 160 0.438 Ppe to Valve (2NV12)
COS.021.083 2NV2FW180-48 MCFI-2NV180 NDE-600 UT SS 4.003 50438 To be done with item Number COS 022 005 Circumferential 40 0.237 Ebow to Elbow C05.021.083A 2NV2FW180-48 MCF1-2NV180 NDE-35 PT SS 4.000 To be done with item Number C05.022.005A Circumferential 40 0.237 Elbow to Elbow
' C05.021.089 2NV2F-4 MCFI-2NV1 NDE-600 UT SS 4.000 50275 Circumferential 160 0.531 Tee to Valve (2NV231)
C05.021.089A 2NV2F-4 MCFI-2NV1 NDE-35 PT SS.
4.000 Circumferential 160 0.531 Tee to Valve (2NV231)
4 o
O O
CATEGORY C-F-1. Pressure RetaininQ QUAUTY ASSUhlANCE ECHNICAL SERVICES Welds in Austenitic SS or Hiah Allow PininQ inservice inspection Database Management System Plan Report EMPS 2 And s NPS 4 McGuire Unit 2 Page 50 Inseevice inspection Plan for interval 2 Outage 1 04/05/m5 ITEM NUMBER ID NUMBER ISO!DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENTS C05.021.095 2NV2FW208-21 MCF1-2NV208 NDE-600 UT SS 4.000 50275 Circumferential 160 0.531 Tee to Valve (2N19A)
C05.021.095A 2NV2FW208-21 MCFI-2NV208 NDE-35 PT SS 4.000 Circumferential 160 0.531 Tee to Valve (2N19A)
Total C05.02111 ems:
22
.- Longitudinal Weld -
C05.022.002 2NV2FW178-79L MCF1-2NV178 NDE 600 UT SS 3.000 50437 To be done with item Number C05.21.053 Longitudinal 40 0.216 Tee to Pye C05.022.002A 2NV2FW178-79L MCF1-2NV178 NDE-35 PT SS 3.000 To de done with item Number C05.021.053A Longitudinal
. 40 0.216 Tee to Ppe C05.022.005 2NV2FW180-48L MCFI-2NV180 NDE-600 UT SS 4.000 50438 To be done with item Number C05.021.083 Longitudinal 40 0.237 Ebow to Elbow C05.022.005A 2NV2FW180-48L MCFI-2NV180 NDE-35 PT SS 4.000 To be done with item Number C05.021.083A Longitudinal 40 0.237 Ebow to Elbow Total C05.022 Items:
4 i
l
O O
O CATEGORY C-F-1. Pressure Retainina DUK ou,t,7y 3SSURA.HCE EC NICAL SERVICES Welds in Austenitic SS or Hiah AlloV Pinina inservice Inspv.;on Database Management Syste'm Plan Report McGuire Unit 2 Page 51 Inservice Insreection Plan for Interval 2 Outage 1 m/05/1995 ITEM NUMBER ID NUMBER ISO /DWG NUMBERS PROC th'SP REO MAT /SCH DIA/THK CAL BLOCKS COMMENTS C05.030.001 2N12F-170 MCF1-2N14 NDE-35 PT SS 2.000 Socket 80 0.218 Reducing insert to Tee C05.030.007 2N12FW122-2 MCFI-2N1122 NDE-35 PT SS 2.000 Socket Valve (2N1164) to Pipe 160 0.344 C05.030.013 2N12FW62-19 MCFI-2Ni62 NDE-35 PT SS 2.000 Socket 160 0.344 Elbow to Pipe C05.030.054 2NV2FW111-6 MCF1-2NV111 NDE-35 PT SS 2.000 Socket 160 0.344 Tee to Reducing insert C05.030.060 2NV2FW179-22 MCFI-2NV179 NDE-35 PT SS 2.000 Socket 160 0.344 Reducer to Ebow C05.030.066 2NV2FW21-18 MCF1-2NV21 NDE-35 PT SS 2.000 Socket 160 0.344 Pipe to Elbow C05.030.072 2NV2FW24-42 MCFl-2NV24 NDE-35 PT SS 2.000 Socket 160 0.344 Ppe to Tee C05.030.078 2NV2FW303-23 MCF1-2NV303 NDE-35 PT SS 2.000 Socket 160 0.344 Reducing insert to Ebow C05.030.084 2NV2FW33-16 MCF1-2NV33 NDE-35 PT SS 2.000 Socket 40 0.154 Poe to Elbow Total C05.030 items:
9
O O
O CATEGORY C-F-1. Pressure RetaininQ QUALITY ASSURANCE EC NICALSERVICES Welds In Austenitic SS or Hiah Allov Piping Inservice inspection Database Management System Plan Report Ploe Branch Connections of Branch Ploina 2 NPS McGuire Unit 2 Page 52 2
Inservice Inspection Plan for Interval 2 Outage 1 04/05/ms ITEM NUMBER ID NUMBER ISO /DWG NUMBERS PROC.
INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENTS
- Circumferential Weld -
C05.041.001 2ND2FW16-24 MCFI-2ND16 NDE-35 PT SS 8.000 Branch 20 0.250 Poe to BC Total C05.041 Items:
1
'I e
O O
O CATEGORY C-F-2. Pressure RetaininQ OUALITY ASSURANCE EC NICAL SERVICES Welds in Carbon Or Low Allov Steel PininQ inservice inspection Database Management System Plan Report Ploina 7."ek-is > 3/8 in. Noininal Wall Tiiickrsss for McGuire Unit 2 Page 53 Pipina > NPS 4 Inservice inspection Plan for Interval 2 Outage 1 04/05/m5 ITEM NUMBER ID NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENIS
+-= Circumferential Weld ~
C05.051.005 2CA2FW50-9 MCFl-2CA50 NDE-600 UT CS 6.000 50331 To be done with item number C05 052.004 Circumferential 80 0.432 Reducer to Pipe C05.051.005A 2CA2FW50-9 MCF1-2CA50 NDE-25 MT CS 6.000 To be done with item number C05.052.004A Circumferential Reducer to Pepe 80 0.432 C05.051.006 2CA2FW51-16 MCF1-2CA51 NDE-600 UT CS 6.000 50331 To be done with item number DOS.052.006 Circumferential 80 0.432 Elbow to Elbow C05.051.006A 2CA2FW51-16 MCF1-2CA51 NDE-25 MT CS 6.000 To be done with item number C05 052.006A Cwcumferential 80 0.432 Ebow to Elbow C05.051.010 2CA2FW50-19 MCFI-2CA50 NDE-600 UT CS 6.000 50281 To be done with item number C05.052.005 Circumferential 160 0.719 Term end Elbow to Nozzle (SG-28)
C05.051.010A 2CA2FW50-19 MCFI-2CA50 NDE-25 MT CS 6.000 To be done with item number C05.052.005A Circumferential 160 0.719 Term end Ebow to Nozzle (SG-28)
C05.051.059 2CF2FW13-1 MCFI-2CF13 NDE-600 UT CS 16.000 50329 To be done with item number C05.052.050 Circumferential 80 0.844 Term end Ebow to Nozzle (SG-2A)
C05.051.059A 2CF2FW13-1 MCFI-2CF13 NDE-25 MT CS 16.000 To be done with item number C05.052.050A Circumferential 80 0.844 Term end Ebow to Nozzle (SG-2A)
C05.051.060 2CF2FW13-12 MCF1-2CF13 NDE-600 UT CS 16.000 50329 To be done with item number C05.052.051 Circumferential 80 0.844 Term end Ebow to Nozzle (SG-2D)
C05.051.060A 2CF2FW13-12 MCF1-2CF13
? DE-25 MT CS 16.000 To be done with item number C05.052.051 A Circumferential 80 0.844 Term end Ebow to Nozzle (SG-2D)
m.
O O
O CATEGORY C-F-2. Pressure RetaininQ QUALITY A SURANCE ECHNICAL SERVICES Welds in Carbon Or Low Allow Steel Pining Inservice inspection Database Management System Plan Report EPIDinc > NPS 4 McGuire Unit 2 Page 54 Inservice inspection Plan for Interval 2 Outage 1 04/05/ms ITEM NUMBER ID NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENTS C05.051.062 2CF2FW15-1 MCF1-2CF15 NDE-600 UT CS 1G000 50329 To be done with item number C05 052 054 Circumferential 80 0.844 Term end Elbow to Nozzle (SG-28)
C05.051.062A 2CF2FW15-1 MCFI-2CF15 NDE-25 MT CS 16.000 To be done with item number C05 052.054 A Circumferential 80 0.844 Term end Elbow to Nozzle (SG-28; C05.051.063 2CF2FW15-12 MCF1-2CF15 NDE 600 UT CS 16.000 50329 To be done with item number C05 052.055 Circumferential 80 0.844 Term end Elbow to Nozzle (SG-2C)
C05.051.063A 2CF2FW15-12 MCFl 2CF15 NDE-25 MT CS 16.000 To be done with item number C05 052.055A Circumferential 80 0.844 Term end Elbow to Nozzle (SG-2C)
C05.051.100 2RV2FW30-15 MCFI-2RV30 NDE-600 UT CS 12.000 50440 To be done with item Number C05.052.100 Circumferential STD 0.375 Ebow to Pipe C05.051.100A 2RV2FW30-15 MCFI-2RV30 NDE-25 MT CS 12.000 To be done with item Number C05.052.100A Circumferential STD 0.375 Ebow to Pipe C05.051202 2SM58-D MCF1-2SM12 NDE-600 UT CS 10.000 50249 Circumferential 1.500 Nozzle (Forged nozzle) to Transnion piece C05.051202A 2SM58-D MCFI-2SM12 NDE-25 MT CS 10.000 Circumferential 1.500 Nozzle (Forged nozzle) to Transition piece C05.051206 2SMSA-D MCFI-2SM8 NDE-600 UT CS 10.000 50249 Circumferential 1.500 Nozzle (Forged nozzle) to Transition piece C05.051206A 2SMSA-D MCF1-2SM8 NDE-25 MT CS 10.000 Circumferential 1.500 Nozzle (Forged nozzle) to Transnion piece
q q
q v
v v
CATEGORY C-F-2. Pressure RetaininQ
^"Y C >ALITY ASSU E EC CAL Welds in Carbon Or Low AlloV Steel PiDin0 Inservice inspection Database Management Sv<. tem Plan Report Ploin0 Welds > 3/8 in. Nominal Wall Tlilckness for McGuire Unit 2 Page 55 PloinD > NPS 4 Inservice inspection Plan for Interval 2 Outage 1 04/05/1995 ITEM NUMBER ID NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIARHK CAL BLOCKS COMMENTS C05.051.213 2SM2F-20 MCFI-2SM1 NDE-600 UT CS 34 000 40415 To be done with item Number C05 052 201 Circumferential 1.250 Elbow to Pipe C05.051.213A 2SM2F-20 MCFI-2SMI NDE-25 MT CS 34.000 To be done with item Number C05 052 201 A Circumferential 1.250 Elbow to Pipe C05.051.218 2Sk12FW8-5 MCFI-2SM8 NDE-600 UT CS 36 000 50385 Circumferential 2.437 Pipe to Valve (2SM7AB)
C05.051.218A 2SM2FW8-5 MCF1-2SM8 NDE-25 MT CS 36.000 Circumferential 2.437 Ppe to Valve (2SM7AB)
C05 051251 2SV2FW2-1 MCFI-2SV2 NDE-600 UT CS 6.000 50331 Circumferential PD 0.432 Valve (2SV2F; to Pipe C05.051.251 A 2SV2FW2-1 MCF1-2SV2 NDE-25 MT OS 6.000 Cncumferential 80 0.432 Valve (2SV26) to Ppe Total C05.051 Itoms:
26
+ + Longitudinal Weld -- -
C05.052.004 2CA2FW50-9L MCF1-2CA50 NDE-600 UT CS 6.000 50331 To be done with item number C05.051.005 Longitudinal 80 0.432 Reducer to Ppe C05.052.004A 2CA2FW50-9L MCF1-2CA50 NDE-25 MT CS 6.000 To be done with item number C05.051.005A Longitudinal 80 0.432 Reducer to Pye C05.052.005 2CA2FW50-19L MCFI-2CA50 NDE-600 UT CS 6.000 50281 To ba done with item number C05.051.010 Longitudinal 160 0.719 Elbow to Nozzle (SG-28)
O O
O CATEGORY C-F-2. Pressure Retainina CUALITY A SURANCE C NICAL SERVICES Welds in Carbon Or Low Allov Steel Plos.na insersice inspection Database Management System Plan Report EPhine > NPS 4 McGuire Unit 2 Page 56 04'05
- 5 Inservice mspection Plan for Interval 2 Outage 1 ITEM NUMBER ID NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENTS C05.052.005A 2CA2FW50-19L MCF1-2CA50 NDE-25 MT CS 6.000 To be done with item number C05 051.010A Longitudinal 160 0.719 Elbow to Nozzle (SG-28)
C05.052.006 2CA2FW51-16L MCF1-2CA51 NDE-600 UT CS 6.000 50331 To be done with item number COS 051.006 Longitudinal 80 0.432 Elbow to Elbow C05.052.006A 2CA2FW51-16L MCF1-2CA51 NDE-25 MT CS 6.000 To be done with item number C05.051.006A Longitudinal 80 0.432 Elbow to Elbow C05.052.050 2CF2FW131L MCFI-2CF13 NDE-600 UT CS 16.000 50329 To be done with item number C05.051059 Longitudinal 80 0.844 Term end Elbow to Nozzle (SG-2A)
C05.052.050A 2CF2FW13-1L MCFl-2CF13 NDE-25 MT CS 16.000 To be done with item number C05.051059A Longitudinal 80 0.844 Term end -
Elbow to Nozzle (SG-2A)
C05.052.051 2CF2FW13-12L Mct-s-2CF13 NDE-600 UT CS 16.000 50329 To be done with item number C05.051.060 Longitudinal 80 0.844 Term end Elbow to Nozzle (SG-2D)
C05.052.051 A 2CF2FW13-12L MCFI-2CF13 NDE-25 MT CS 16.000 To be done with item number C05.051.060A Lc. igitudinal 80 0.844 Term end Elbow to Nozzle (SG-2D)
C05.052.054 2CF2FW15-1L MCF1-2CF15 NDE-600 UT CS 16.000 50329 To be done with item number C05.051.062 Longitudinal 80 0.844 Term end Ebow to Nozzle (SG-28)
C05.052.054A 2CF2FW15-1L MCF1-2CF15 F 25 MT CS 16.000 To be done with item number C05.051.062A Longitudinal 80 0.844-Term end Elbow to Nozzle (SG-28)
C05.052.055 2CF2FW15-12L MCF1-2CF15 NDE-600 UT CS 16.000 50329 To be done with item number C05.051.063 Longitudinal -
80 0.844 Term end Elbow to Nozzle (SG-2C)
O O
O CATEGORY C-F-2. Pressure RetalninQ DUKE POWER COMPANY OUALITY ASSURANCE TECHNICAL SERVICES Welds in Carbon Or Low Allov Steel PininQ inservice inspection Database Management System Plan Report
" bias fe:Js > 3/8 in. NG.r.;aal Wall Tiiidr+ss for McGuire Unit 2 Page 57 E-t;aG > NPS 4 Inservice inspection Plan for interval 2 Outage 1 M/05/m5 ITEM NUMBER ID NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENTS C05.052.055A 2CF2FW15-12L MCFI-2CF15 NDE-25 MT CS 16.000 To be done with item number C05.051.063A Longitudinal 80 0.844 Term end Elbow to Nozzle (SG-2C)
C05.052.100 2RV2FW30-15L MCFI-2RV30 NDE-600 IJ CS 12.000 50440 To be done with item Number C05.051.100 Longitudinal STD 0.375 cibow to Pipe C05.052.100A 2RV2FW30-15L MCFl-2RV30 NDE-T.5 MT CS 12.000 To be done with item Number COS 051.100A Longitudinal STD 0.375 Elbow to Pipe C05.052.201 2SM2F-20L MCFI-2SM1 NDE-600 UT CS 34.000 40415 To be done with item Number C05.051.213 Longitudinal 1.250 Elbow to Pipe C05.052.201 A 2SM2F-20L MCFI-2SM1 NDE-25 MT CS 34.000 To be done with item Number C05.052 213A Longitudinal 1.250 Elbow to Pipe j
Total C05.052 Items:
18 l
Total Category C-F-2 Items:
126
o O
O CATEGORY C-G. Pressure Retainina Welds QUALITY ASS NC CHf# CAL SERVICES in Pumos And Valves inservice Inspection Database Management System Plan Report Vaties McGuire Unit 2 Page 58 Inservice inspection Plan for Interval 2 Outage 1 M/05/1995 ITEM NUMBER ID NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENIS a Valve Body Welds ****
C06 020.003A 2NV-237-1 MCF1-2NV31 NDE-35 PT SS 3.000 VALVE BODY TO SE AI RING INSERT MCM 1205.00-15 0.000 C06 020.003B 2NV-237-2 MCF1-2NV31 NDE-35 PT SS 3.000 VALVE BODY TO SE AT RING INSERT MCM 1205.00-15 0.000 Total C06.020 hems:
2 Total Category C.G hems:
2
.. -.-- -. = -.
O O
O
" POW "
CATEGORY D-B. Systems in Sunoort Of QUAUW A SURA E ECHNICAL SERVICES ECC. CHR. Atmos. Cleanun. And Reactor inservice Inspection Database Management System Plan Report Integral Attachment McGuire Unit 2 Page 59 inservice inspection Plan for Interval 2 Outage 1 wos/ms ITEM NUMBER ID NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS C-OMMENTS
- Component Supports and Restraints -
D02.020.021 2MCA-KC-3328 2KC-351 OAL-14 VT-3 NA 0.000 RIGID SUPPORI Rgid support (SHT.2OF7) 0.216 PIPE ATT.
Total D02.020 items:
1 Total Category D-B llems:
1
D O
O CATEGORY F-A. Suonorts (Cateaorv A)
D KE POWER COMPANY OUALITY ASSURANCE TECHNICAL SERVICES Inservice inspection Database Managernent System Plan Report Class 1 Ploina 9sanarls McGuire Unit 2 Page 60 Inservice Inspection Plan for interval 2 Outage 1 04'05'
- 5 ITEM NUMBER ID NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENTS F01.010.001C 2MCR-NC-4500 2NC-201(SHT.10F1)
OAL-14 VT-3 NA 14.000 Spnng hanger 0.000 F01.010.006C 2MCR-NC-4253 2NC-210(SHT.10F1)
OAL-14 VT-3 NA 2.000 Mech snubber 0.000 F01.010.007C 2MCR-NC-4254 2NC-210(SHT.10F1)
OAL-14 VT-3 NA 2.000 Mech snubber 0.000 F01.010 014B 2MCR-NC-4120 2N1-203(SHT.10F2)
OAL-14 VT-3 NA 10.000 Rigd support 0.000 F01.010.016C 2MCR-NC-4100 2NI-203(SHT20F2)
OAL-14 VT-3 NA 10.000 Mech snubber o.000 F01.010.017C 2MCR-NC-4083 2NI-215(SHT.10F1)
OAL-14 VT-3 NA 1.500 Mech snubber 0.000 F01.010.019A 2MCR-NC-4093 2NV-204(SHT.10F3)
OAL-14 VT-3 NA 2.000 Rigid restraint o.000 F01.010.076A 2MCR-NI-4949 2ND-201(SHT.2OF2)
OAL-14 VT-3 NA 8.000 Rigid support 0.000 F01.010.077C 2MCR-NI-4943 2ND-201(SHT.2OF2)
OAL-14 VT-3 NA 8.000 Mech snubber o.000 F01.010.078A 2MCR-NI-4654 2ND-201(SHT.2OF2)
OAL-14 VT-3 NA 8.000 Rigid restraint
- o. coo
O O
O CATEGORY F-A. Suncorts (Cateaorv A)
OUAUTY ASSURAN E ECHNICAL SERVICES i
inservice inspection Database Management System Plan Report f
Class 1 Pipisg Supports McGuire Unit 2 Page 61 inservice Inspection Plan for interval 2 Outage 1 M/os/ms ITEM NUMBER ID NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENTS T tal F01.010 items:
10 4
1
O O
O CATEGORY F-A. Sunnorts (Cateaory A)
D KE POWER COMPANY QUALITY ASSURANCE TECHNICAL SERVICES Inservice inspection Database Management System Plan Report Class 2 Pipino Supports McGuire Unit 2 Page 62 04/05/1995 Inservice inspection Plan for Interval 2 Outage 1 ITEM NUMBER ID NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK C#L BLOCKS COMMENTS F01.020.003A 2MCA-CA-H15 2 CAM (SHT.2 OF 2)
OAL-14 VT-3 NA 6.000 Rgd restraint 0 000 F01.020.006C 2MCR-CA-H94 2CAO (SHT.10F 2)
OAL-14 VT-3 NA 6.000 Mech snubber 0.000 F01.020.100C 2MCA-ND-5204 2FW-350(SHT.3OF5)
OAL-14 VT-3 NA 12.000 Mech snubber 0.000 F01.020.101C 2MCA-ND-5211 2FW-350(SHT.3OF5)
QAL-14 VT-3 NA 12.000 Rgid restraint 0.000 F01.020.102A 2MCA-ND-5307 2FW-350(SHT.40FS)
OAL-14 VT-3 NA 18.000 Rgd restraint 0.000 F01.020.103C 2MCA-ND-5311 2FW-350(SHT.40F5)
OAL-14 VT-3 NA 12.000 Mech snubber 0.000 F01.020.1588 2MCR-NI-4821 2NI-208(SHT.10F1)
OAL-14 VT-3 NA 4.000 Rigid restraint 0.000 F01.020.1598 2MCR-NI-4825 2NI-208(SHT.10F1)
OAL-14 VT-3 NA 2.000 Rigid testraint 0.000 F01.020.160A 2MCR-NI-4787 2NI-209(SHT.10F2)
OAL-14 VT-3 NA 4.000 Rigid restraint 0.000 F01.020.161 A 2MCR-NI-4772 2NI-209(SHT.10F2)
OAL-14 VT-3 NA 4.000 Rgid restraint 0.000
i l
0 0
0 CATEGORY F-A. Suonorts (Cateaory A)
DUKE POWER COMPANY OUALITY ASSURANCE TECHNICAL SERVICES inservice inspection Database Managernent System Plan Report Class 2 Pinino Succorts McGuire Unit 2 Page 63 inservice inspection Plan for interval 2 Outage 1 04'95'1995 ITEM NUMBER ID NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SOH DIA/THK CAL BLOCKS COMMENTS F01.020.168B 2MCR-NI-4899 2NI-213(SHT.10F1)
OAL-14 VT.3 NA 3.000 Rigid restraint 0.000 F01.020.169C 2MCR NI-4896 2NI-213(SHT.10F1)
OAL-14 VT-3 NA 3.000 Mech snubber 0.000 F01.020.170A 2MCR-NI-4892 2Ni-213(SHT.10F1)
OAL-14 VT-3 NA 3.000 Rigid restraint 0.000 F01.020.171C 2MCR-N1-4134 2N1-215(SHT.10F1)
OAL-14 VT-3 NA 3.000 Mech snubber 0.000 F01.020.175B 2MCA-Ni5036 2NI-350(SHT.3OF3)
OAL-14 VT-3 NA 4.000 Rgd restraint 0.000 F01.020.176B 2MCA-NI-5718 2NI-350(SHT.3OF3)
OAL-14 VT-3 NA 4.000 Rigd restraint 0.000 F01.020.177A 2MCA-NI-5207 2NI-352(SHT.10F1)
OAL-14 VT-3 NA 12.000 Rgid restraint 0.000 F01.020.1788 2MCA-NI-5806 2NV-353(SHT.3OF3)
OAL-14 VT-3 NA 4.000 Rgid restraint 0.000 F01.0202028 2MCR-NS-4515 2NS-201(SHT.10F1)
OAL-14 VT-3 NA 8.000 Rgid restraint 0.000 F01.020.203B 2MCR-NS-4566 2NS-202(SHT.10F2)
OAL-14 VT-3 NA 8.000 Rgid restraint 0.000 l
O O
O CATEGORY F-A. Suncorts (Cateaorv A)
DUKE POWER COMPANY OUALITY ASSURANCE TECHNICAL SERVICES Inservice inspection Database Managernent System Plan Report Class 2 Ploina 9aaaarts McGuire Unit 2 Page 64 Inservice Inspection Plan for Interval 2 Outage 1 04/05/1995 ITEM NUMBER ID NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENTS F01.020.2048 2MCR-NS-4551 2NS-202(SHT.2OF2)
OAL-14 VT-3 NA 8.000 Rgd restraint 0.000 F01.020.205B 2MCR-NS-4555 2NS-202(SHT.2OF2)
OAL-14 VT 3 NA 8.000 Ragd restraint 0.000 F01.020.432C 2MCA-SM-H24 2SMA (SHT.2OFS)
OAL-14 VT-3 NA 36.000 Mech snubber 0.000 F01.020.439C 2MCA-SM-H69 2SMA (SHT.40F5)
OAL-14 Vl-3 NA 36.000 Mech snubber 0.000 F01.020.5008 2MCR-VO-4544 2VO-201(SHT.10F1)
OAL-14 VT-3 NA 6.000 Rgd restraint 0.000 F01.020.503C 2MCR-VO-4507 2VO-202(SHT.10F1)
OAL-14 VT-3 NA 6.000 Spring hanger 0.000 F01.020.525B 2MCR-WL-4061 2WL-207(SHT.10F3)
OAL-14 VT-3 NA 6.000 Rigd restraint 0.000 Total F01.020 Roms:
27
- J
D O
O CATEGORY F-A. Sunnorts (Cateaorv A)
OUALITY A S ANCE C NICALSERVICES Inservice inspection Database Managernent System Plan Report Class 3 Pinina %anarts McGuire Unit 2 Page 65 Inservice inspection Plan for interval 2 Outage 1 w05n%5 ITEM NUMBER ID NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENTS F01.030.001 B 2MCA-CA-5160 2CA-351(SHT.10F4)
OAL-14 VT-3 NA 8.000 Rgd restraint 0.000 F01.030.002A 2MCA-CA-5210 2CA-351(SHT.2OF4)
OAL-14 VT-3 NA 8.000 Rgd restraint 0.000 F01.030.004C 2MCA-CA-5461 2CA-354(SHT.10F2)
OAL-14 VT-3 NA 4.000 Spring hanger 0.000 F01.030.018C 2MCA-CA-H170 2CAO (SHT.2OF2)
OAL-14 VT-3 NA 4.000 Mech snubber 0.000 F01.030.050A 2MCR-KC-4022 2KC-201(SHT.10F1)
OAL-14 VT-3 NA 8.000 Rgd restraint 0.000 F01.030.051 C 2MCR-KC-4557 2KC-201(SHT.10F1)
OAL-14 VT-3 NA 6.000 Mech snubber 0.000 F01.030.052A 2MCR-KC-4054 2KC-202(SHT.10F3)
OAL-14 VT-3 NA 6.000 Rigid restraint 0.000 F01.030.053A 2MCR-KC-4057 2KC-202(SHT.2OF3)
O AL-14 VT-3 NA 8.000 Rigid restraint 0.000 F01.030.054B 2MCR-KC-4503 2KC-202(SHT.2OF3)
GAL-14 VT-3 NA 8.000 Rigid restraint 0.000 F01.030.055A 2MCA-KC-3327 2KC-351(SHT.10F7)
OAL-14 VT-3 NA 6.000 Rigid restraint
~
0.000
O O
O CATEGO5tY F-A. Suonorts (Catenorv Al QUAUTY ASS E
AL SERVICES Inservice k;spection Database Management System Plan Report e- ---
McGuire Unit 2 Page 66 M
Inservice inspection Plan for Interval 2 Outage 1 M/05/ms ITEM NUMBER 10 NUMBER ISO /DWG NUMBERS PROC INSPREO MAT /SCH DIA/THK CAL BLOCKS COMMENTS F01.030.056A 2MCA-KC-3328 2KC-351(SHT.2OF7)
OAL-14 VT-3 NA 8.000 Rgd restraint o_000 F01.030.061 A 2MCA-KC-3285 2KC-351(SHT.3OF7)
OAL-14 VT-3 NA 10.000 Rgd restraint o oco Total F01.030 Itoms:
12 l
E
O O
O CATEGORY F-A. SUPPORTS DUKE POWER COMPANY QUALITY ASSURANCE TECHNICAL SERVICES Inservice inspection Database Management System Plan Report 7=- =is si;.- than M. G % = =is (Cl*** 1. 2.
McGuire Unit 2 Page 67 M
inservice inspection Plan for interval 2 Outage 1 04'05# 8 5 ITEM NUMBER 10 NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENTS F01.040.002 2PZR-LUGS MC 1070-6 OAL-14 VT-3 NA 0.000 PRESSURIZER LUGS MCM 2201.01-15 0.000 MCM 2201.01-16 F01.040.0(43 2NSP-SUP-2A MCM 1201.06-206 OAL-14 VT-3 NA 0.000 2A CONTAINMENT SPRAY PUMP SUPPORT MC 1220-74, 0.000 F01.040.009 2NS-HX-SUP-2A MCM 1201.06-25 OAL-14 VT-3 NA 0.000 2A CONTAINMENT SPRAY HX SUPPORT MC 1220-32 0.000 MC 1220-103 MC 1223-1 F01.040.010 2 REG-HX-SUP MCM 1201.06-54 OAL-14 VT-3 NA 0.000 REGENERATIVE HX SUPPORT MCM 1201.06-69 0.000 F01.040.011 2EXLD-HX-SUP OAL-14 VT-3 NA 0.000 EXCESS LETDOWN HX SUPPORT MCM 1201.06-54 0.000 a
F01.040.015 2SW-HX-SUP OAL-14 VT-3 NA 0.000 SEAL WATER HX SUPPORT MCM 1201.06-009 MC 1220 e 0.000 MCM 1201.06-54 Total F01.040 Nome:
6 Total Category F-A Items:
55
O O
O CATEGORY AUG. Auamented inspections QUAUTY A URANCE ECHNICAL SERVICES Inservice inspection Database Management System Plan Report
$ Aamented Exam. Reactor Coolant Pumo McGuire Unit 2 Page 68 yJFlywtieel inservice inspection Plan for Interval 2 Outage 1 04/05/ms rfEM NUMBER ID NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENTS G01.001.002 2RCP-28 NDE-900 UT CS 0.000 FLYWH REACTOR COOLANT PUMP FLYWHEEL 28 INSPECT MC1201.01-7 0 000 ONCE EVERY THREE YEARS (NOT TO EXCEED THREE YEARS BETWEEN INSPECTIONS)
G01.c01.004 2RCP-2D NDE-900 UT CS 0.000 FL[EH REACTOR COOLANT PUMP FLYWHEEL 2D INSPECI mci 201.01-7 0.000 ONCE EVERY THREE YEARS (NOT TO EXCEED THREE YEARS BETWEEN INSPECTIONS)
Total G01.001 Items:
2 Total Category AUG ltems:
2 i
O.
O o
CATEGORY AUG. Augmented inspections QUALITY A TE SERVICES inservice inspection Detsbese Management System Plan Report inservice inspectio for nterval 2 Outage 1 ITEM NUMBER ID NUMBER ISOOWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENTS i
G02.001.001 2SGA-TUBES ET NA 0.000 INFO ON SG TUBE EXAMS CAN BE ACQUIRED 0.000 FROM THE DIVERSFIED SERVICES GROUP OF THE ELEC. SYSTEM DEPT. OF DPC i
G02.001.002 2SG8-TUBES ET NA 0.000 INFO ON SG TUBE EXAMS CAN BE ACOUIRED 0.000 FROM THE DIVERSFIED SERVICES GROUP OF THE ELEC. SYSTEM DEPT.OF DPC l
l G02.001.003 2SGC-TUBES ET NA 0.000 INFO ON SG TUBE EXAMS CAN BE ACQUIRED 0.000 FROM THE DIVERSFIED SERVICES GROUP OF THE ELEC. SYSTEM DEPT.OF DPC G02.001.004 2SGD-TUBES ET NA 0.000 INFO ON SG TUBE EXAMS CAN BE ACQUIRED 0.000 FROM THE DIVERSFIED SERVICES GROUP OF THE ELEC. SYSTEM DEPT. OF DPC Total G02.001 Items:
4 Total Category AUG Items:
4 i
1
O O
O CATEGORY AUG. Auarnented Inspections MPAN QUA W A C
, SERVICES inservice inspection Database Management System Plan Report Auomented Exam. Ploe Rupture Protection McGuire Unit 2 Page 70 Inservice inspection Plan for Interval 2 Outage 1 M/05/ m s ITEM NUMBER ID NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENTS G03.001.001 2NC2FW16-1 MCFI-2NC16 NDE 600 UT SS 10.000 50209 PIPE RUPTURE PROTECTION Circumferential MC 2553-1.0 1.000 Elbow to Nozzle G03.001.001 A 2NC2FW16-1 MCF1-2NC16 NDE-35 PT SS 10.000 PIPE RUPTURE PROTECTION Circumferential MC 2553-1.0' Elbow to Nozzle 1.000 Total G03.001 llems:
2 Total Category AUG llems:
2
o o
O CATEGORY AUG. Auarnented inspections QUALITY A C NICAL SERVICES Inservice Inspection Database Management System Plan Report Aa_-Tweatiwi Fumai. Steam Gis.eimici Fis';;23r McGuire Unit 2 Page 71
_ I E aiivn Inservice inspection Plan for Interval 2 Outage 1 04'05'1 " 5
~
ITEM NUMBER ID NUMBER ISO /DWG NUMBERS PROC INSP REO MAT /SCH DIA/THK CAL BLOCKS COMMENTS G04.001.004 2SGD-CF-MOD OAL14 VT 3 CS 0.000 STEAM GENERATOR 2D FEEDWATER 0.000 MODIFICATION Total G04.001 Items:
1 Total Category AUG llems:
1
~
n B.
Items examined by Pressure Testing V
Item Number ASME Section XI Tables IWB-25001
=
(Class 1), IWC-2500-1 (Class 2) i Drawing Number = Number of the Flow Diagram j
Revision Revision of the Flow Diagram
=
i Test Type of Pressure Test
=
Vessel, Piping or Pump Comp
=
i Example: Reactor Vessel, etc.; for i
Comp Name
=
piping-System designation will be used Req.Insp.
Type inspection performed, i.e., VT2 -
=
Req. Proc.
Required inspection procedure
=
Comments General and/or Detail Description
=
o O
Refueling Outage Report Page 2 McGuire Unit 2 Revision 0 Section 4 April 5,1995
_...m._
..m
~
O O
O PAGE NO. I kGUIRE UNIT NUBEER 2 - M N 04/05/95 CLASS A (CATEGORY B-P) REQUInenartrra FOR OUTAGE NUtmER S t
REQ.
REQ.
ITEM NO.
DRANING REV TEST FCh NO.
SYSTEM Mans INSP PROC CateENTS B15.050.001 SEE COMMENTS N/A LEAKAGE 2MNS-016 NC SYSTEM VT-2 QAL-15 Class A Leakage Boundary Dwgs:
MCL-2553-1.0/2, MCL-2553-2.0/2, MCL-2554-1.0/2, MCL-2554-1.1/2, MCL-2554-1.2/2, MCL-2561-1.0/2, MCL-2562-1.0/2, MCL-2562-2.0/2, MCL-2562-2.1/2, MCL-2562-3.0/2, MCL-2562-3.1/2 t
.- ~. - -.
- -. ~. -
O O
O PAGE NO. 1 McGUIRE UNIT Nrnmen 2 - 2nd INTERVAL 04/05/95 CIASS B (CATEGORY C-R) REQUIRE 8ENTS FOR ooTacE NummER s REQ.
REQ.
ITEM NO.
DRAWING REV TEST FCA NO.
SYSTEld Whlg INSP PROC rysamers C07.030.001 MCL-1554-5.0 04 INSER 2MNS-016 NV SYSTEM VT-2 QAL-15 This test is required for periods 1 and 3 -
Reference PIPf2-M95-0043 4
C07.030.002 MCL-2554-2.0 02 INSER 2MNS-016 NV SYSTEM VT-2 QAL-15 This test is required for periods 1,2 and 3
- PIPf2-M95-0043 C07.030.003 MCL-2554-3.0 02 INSER 2MNS-016 NV SYSTEM VT-2 QAL This test is required for periods 1,2 and 3
- PIPf2-M95-0043 C07.030.004 MCL-2554-3.1 02 ANSER 2MNS-015 NV SYSTEM VT-2 QAL-15 This test is required for periods 1,2 and 3
- Reference PIPf2-M95-0043 C07.030'.005 MCL-2561-1.0 02 INSER 2MNS-016 ND SYSTEM VT-2 QAL-15 VT-2 Examination of CO2.033.001 and CO2.033.002 Telltsle Hole also required -
Reference PIPS 2-M95-0043 C07.030.006 MCL-2562-1.0 02 INSER 2MNS-016 NI SYSTEM VT-2 QAL-15 Penetration M-351 - Reference PIPf2-M95-0043 C07.030.007 MCL-2562-2.0 02 INSER 2MNS-016 NI SYSTEM VT-2 QAL-15 This test is required for periods 1,2 and 3
- Penetration M-330 - Reference PIPS 2-M95-0043 C07.030.008 MCL-2562-2.1 02 INS / FUN 249tS-016 NI SYSTEM VT-2 QAL-15 This test is required for periods 1,2 and 3
- Penetration M-321 - Reference PIPS 2-M95-0043 C07.030.009 MCL-2562-3.0 02 INS / FUN 2MNS-016 NI SYSTEM VT-2 QAL-15 This test is required for periods 1,2 and 3
- Reference PIP 92-M95-0043 C07.030.012 MCI)-25 63-1.0 03 INS / FUN 2MNS-016 NS SYSTEM VT-2 QAL-15 VT-2 Examination of CO2.033.005 and CO2.033.006 Telltale Hole also required -
Reference PIPf2-M95-0043 C07.030.014 MCL-2565-1.1 02 INSER 2MNS-016 WL SYSTEM VT-2 QAL-15 PIPf2-M95-0043 C07.030.015 MCL-2571-1.0 02 INSER 2MNS-016 EW SYSTEM VT-2 QAL-15 This test is required for periods 1,2 and 3 Penetrations 2M-358 and 2M-377 - Reference PIPS 2-M95-0043 C07.030.016 290L-2556-3. 0 02 INSER 2MNS-016 NB SYSTEM VT-2 QAL-15 Penetration M-259 i
- ~. - _..
~.
O O
O PAGE NO. 2 McGUIRE UNIT NUMBER 2 - 2nd INTERVAL 04/05/95 CIASS B (CATEGORY C-R) REQUIan esTS FOR OUTAGE NURSER 9 REQ.
REQ.
ITEM NO.
DRANING REV TEST FCE NO.
SYSTEM Mhtm INSP PROC tvunerTS C07.030.017 MCL-2572-1.0 02 INSER 2MNS-017 NM SYSTEM VT-2 QAL-15 Penetrations M-235 and M-309 C07.030.018 MCL-2572-1.1 01 INSER 2MNS-016 NM SYSTEM VT-2 QAL-15 Penetration M-280 - Reference PIPf2-M95-0043 C07.030.020 MCL-2572-3.0 03 INSER 2MNS-018 NM SYSTEM VT-2 QAL-15 Class B penetrations M-335, M-338, M-340 and M-341 C07.030.021 MCL-1599-2.2 01 INSER 2MNS-015 RF SYSTEM VT-2 QAL-15 PIP 92-M95-0043 C07.030.022 MCL-2605-2.2 02 INSER 2MNS-016 VS SYSTEM VT-2 QAL-15 Penetration M-219 - PIPi2-M95-0043.
C07.030.023 HCL-2573-3.1 02 INSER 2MNS-016 KC SYSTEM VT-2 QAL-15 Penetrations M-217, M-218, M-320, M-327, M-355 and M-376 C07.030.024 MCL-2573-4.0 02 INSER 2MNS-016 KC SYSTEM VT-2 QAL-15 Penetration M-322 C07.030.025 MCL-2574-4.0 04 INSER 2MNS-016 RN SYSTEM VT-2 QAL-15 Penetrations M-307 and M-315 - Reference PIPf2-M95-0043 C07.030.026 MCL-2580-1.0 03 INSER 2MNS-018 BB SYSTEM VT-2 QAL-15 Penetrations M-300, M-301, M-303 and M-304 C07.030.028 MCL-2591-1.1 02 INSER 2MNS-017 CF SYSTEM VT-2 QAL-15 Penetrations M-153, M-262, M-308 and M-440 C07.030.029 MCL-2593-1.0 02 INSER 2MNS-017 SM/SV SYSTEM VT-2 QAL-15 Class B penetrations M-154 and M-261 -
Reference PIPf2-M95-0043 C07.030.030 MCL-2593-1.3 02 INSER 2MNS-017 SM/SV SYSTEM VT-2 QAL-15 Class B penetrations M-393 and M-441 -
Reference PIPf2-M95-0043 C07.030.031 MCL-2592-1.0 01 INSER 2MNS-016 CA SYSTEM VT-2 QAL-15 Penetrations M-156, M-286, M-465 and M-3100
__m
.m.. _ _ _ _ -.
m. _._
O O
O PAGE NO. 3 MoGUIRE UNIT NERGER 2 - 2nd INTERVAL 04/05/95 CLASS B (CATEGORY C-R) REQUIn-Tg i
FOR OUTAGE NURSER S REQ.
BEQ.
ITEnt 30.
DRANING REV TEST FCk WO.
SYSTEM NAas INSP PROC CrenamTg C07.030.032 MCL-2593-1.2 02 INSER 2MNS-016 SA/TE SYSTEM VT-2 QAL-15 Reference PIPS 2-M95-0043 C07.030.033 MCL-2605-1.3 01 INSER 2MNS-016 VI SYSTEM VT-2 QAL-15' Class B penetrations M-220 and M-359 -
Reference PIPS 2-M95-0043 C07.030.034 MCL-2617-1.0 01 INSER 2MNS-016 YA SYSTEM VT-2 QAL-15 Reference PIPS 2-M95-0043 C07.030.035 MCL-2553-2.0 02 INSER 2MNS-016 NC SYSTEM VT-2 QAL-15 This test is required for periods 1,2 and 3.
- Penetrations M-212, M-216 and M-276 -
Reference PIPf2-M95-0043 C07.030.037 MCL-2554-1.0 02 INSER 2MNS-017 NV SYSTEM VT-2 QAL-15 This test is required for periods 1,2 and 3
- Penetrations M-339 and M-350 -
PIPS 2-M95-0043 C07.030.038 MCL-2554-1.1 02 INSER 21elS-017 NV SYSTEM VT-2 QAL-15 This test is required for periods 1,2 and 3
- Penetrations M-256, M-343 and M-344 -
PIPf2-M95-0043 C07.030.039 MCL-2554-1.2 02 FUNCT 2MNS-016 NV SYSTEM VT-2 QAL-15 This test is required for periods 1,2 and 3
- Penetrations M-228, M-329 and M-347 PIPf2-M95-0043 C07.030.040 MCL-2554-1.3 02 FUNCT 2MNS-017 NV SYSTEM VT-2 QAL-15 This test is required for periods 1,2 and 3
- Penetration M-342 - Reference PIPS 2-M95-0043 C07.030.041 MCL-2604-3.0 04 INSER 2MNS-015 VI SYSTEM VT-2 QAL-15 Penetrations M-240, M-279, M-385 and M-390 -
Reference PIPf2-M95-0043.
C07.030.042 MCL-1601-2.4 02 INSER 2MNS-015 YM SYSTEM VT-2 QAL-15 Reference PIPf2-M95-0043 C07.030.043 MCL-2605-1.16 01 INSER 2MNS-016 VI SYSTEM VT-2 QAL-15 Reference PIPf2-M95-0043
O O
O PAGE NO. 1 BloGUIRE UNIT WUteER 2 - 2nd DrTERVAL 04/03/95 CIASS C (CETEGORY D-A) REQUIREBEETS Fom opracE uuteER s REQ.
REQ.
ITEtt 30.
DRANING REV TEST FCh NO.
SYSTEBf Engs INSP PROC naamtTS D01.011.001 MCL-1554-5.0 04 INSER 2MNS-016 NV SYSTEM VT-2 QAL-15 Reference PIPf2-M95-0043 D01.011.002 MCL-2554-3.1 02 INSER 2MNS-015 NV SYSTEM VT-2 QAL-15 This test is required for periods 1,2 and 3
- Reference PIPf2-M95-0043 D01.011.003 MCL-2554-5.0 02 INSER 2MNS-016 NV SYSTEM VT-2 QAL-15 This test is required for periods 1,2 and 3
- Reference PIPf2-M95-0043 D01.011.004 MCL-2554-2.0 02 INSER 2MNS-016 NV SYSTEM VT-2 QAL-15 Reference PIPf2-M95-0043 s
O O4 I
V PAGE NO. 1 McGUIRE UNIT NUteER 2 - 2nd INTERVAL 04/05/95 CLASS C (CETEGORY D-B) REQUIRE 3mWTS FOR OUTAGE NUteER 9 REQ.
REQ.
ITEM NO.
DRANING REV TEST FCk NO.
SYSTEM Mham INSP PROC CoeSENTS D02.011.001 MCL-1574-1.0 03 FUNCT 2MNS-016 RN SYSTEM VT-2 QAL-15 Reference PIPf2-M95-0043 D02.011.002 MCL-1574-1.1 03 FUNCT 2MNS-016 RN SYSTEM VT-2 QAL-15 Reference PIPf2-M95-0043 D02.011.003 MCL-1574-2.0 03 FUNCT 2MNS-016 RN SYSTEM VT-2 QAL-15 Reference PIPf2-M95-0043 D02.011.004 MCL-1574-3.0 03 FUNCT 2MNS-016 RN SYSTEM VT-2 QAL-15 Reference PIPf2-M95-0043 D02.011.006 MCL-2573-1.1 02 FUNCT 2MNS-016 KC SYSTEM VT-2 QAL-15 Reference PIPf2-M95-0043 D02.011.007 McL-2574-1.1 04 FUNCT 2MNS-016 RN SYSTEM VT-2 QAL-15 Reference PIPS 2-M95-0043 1
D02.011.008 MCL-2574-2.1 01 FUNCT 2MNS-016 RN SYSTEM VT-2 QAL-15 Reference PIPf2-M95-0043 D02.011.009 MCL-2574-2.0 02 FUNCT 2MNS-016 RN SYSTEM VT-2 QAL-15 Reference PIPf2-M95-0043 D02.011.010 MCL-2574-3.0 04 FUNCT 2MNS-016 RN SYSTEM VT-2 QAL-15 Reference PIPf2-M95-0043 D02.011.011 MCL-2574-3.1 01 FUNCT 2MNS-016 RN SYSTEM VT-2 QAL-15 Reference PIPf2-M95-0043 D02.011.013 MCL-2592-1.0 01 FUNCT 2MNS-016 CA SYSTEM VT-2 QAL-15 Reference PIPf2-M95-0043 D02.011.014 MCL-2592-1.1 02 FUNCT 2MNS-016 CA SYSTEM VT-2 QAL-15 Reference PIPf2-M95-0043 D02.011.015 MCL-2593-1.2 02 FUNCT 2MNS-016 SA/TE SYSTEM VT-2 QAL-15 Reference PIPf2-M95-0043 4
O O
O PAGE NO. 2 McGUIRE tlEIT NUISER 2 - 2nd IsrfERVAL 04/05/95 CLASS C (CATEGORY D-3) REQUIREamarFS FOR ocraaR NoemEn s REQ.
REQ.
ITEM NO.
DRANIBIG REV TEST FCA NO.
SYSTEng unnat INSP PROC rarmamrFS D02.011.016 MCL-2609-1.0 02 FUNCT 2MNS-016 KD SYSTEM VT-2 QAL-15 Reference PIPS 2-M95-0043 D02.011.017 MCL-2609-1.1 02 FUNCT 2MNS-Ol6 KD SYSTEM VT-2 QAL-15 Reference PIPG2-M95-0043 DC2.011.018 MCL-2609-2.0 02 FUNCT 2MNS-016 LD SYSTEM VT-2 QAL-15 Reference PIPS 2-M95-0043 D02.011.019 MCL-2609-2.1 02 FUNCT 2 MIS-016 LD SYSTEM VT-2 QAL-15 Reference PIPS 2-M95-0043 D02.011.021 MCL-2609-3.1 02 FUNCT 2MNS-016, FD SYSTEM VT-2 QAL-15 This test is required for periods 1,2 and 3
- Reference PIPf2-M95-0043 D02.011.022 MCL-2609-4.0 02 FUNCT 2MNS-016 VG SYSTEM VT-2 QAL-15 Reference PIPf2-M95-0043
-.__.__m.
.. -.__.. -. _.. ~....... _.. _.. - _ -.. - - -. - - -.. -.
O O
O PAGE NO. 1 MIRE UNIT N 2 - 2nd N 04/05/95 CIASS C (CATEGORY D-C) REQUIMS FOR OUTAGE NUISER 9 REQ.
REQ.
ITEtt 30.
DRANING REV TEST FCE NO.
SYSTElf Rhts ING PROC tvemeurs D03.011.001 MCL-2570-1.0 02 INSER 2MNS-016 KF SYSTEM VT-2 QAL-15 This test is required for periods 1,2 and 3
- Reference PIP 92-M95-0043 i
1 1
q 5.0 Results OfInanections Perforrned Durina Outnae 9 b
The results of each examination shown in the final ISI Plan (Section 4 of this report) are included in this section. The completion date and status for each examination are shown.
All examinations revealing reportable indications are described in further detail in Section 6.
5.1 The information shown below is a field description for the reporting l
format included in this section of the report:
A.
Items examined by NDE methods 1
Item Number ASME Section XI Tables IWB-2500-1
=
(Class 1), IWC-2500-1 (Class 2),
IWF-2500-1 (Class 1, Class 2),
Augmented and Alternate Requirements ID Number Unique Identification Number
=
Inspection Date Date of Examination
=
Inspection Status
=
CLR Clear
=
REC Recordable
=
O REP Reportable
=
- Inspection Limited
- Reference paragraph 5.2
=
L Limited
=
No
=
Geo. Ref.
= Geometric Reflector (Applies only to UT)
N
= No Y
= Yes Comments
= General and/or Detail Description AL)
Refueling Outage Report Page1 McGuire Unit 2 Revision 0 Section 5 January 23,1995
DUKE POW COMPANY OUALITY ASSURANCE TECHNICAL SERVICES In-Service inspection Database Management System RunD McGuire Unit 2 inservice inspection Listing Plant: McGuire Unit 2 bterval 2 Nage 1 Page1 04/05/1995 ITEM NUMBER ID NUMBER INSP DATE INSP STATUS INSP LIMITED GEO REF COMMENTS B01.021.002 2RPV-WOI 11/26/1994 CLR N
B01.030 001 2RPV.WO7 12/01/1994 CLR N
B03.090.005A 2RPV-W15 08/09/1993 REC 43.70 %
Y B03.093.006A 2RPV-W16
^
08/09/1993 REC 43.70 %
Y B03.090.007A 2RPV-W17 08/09/1993 REC 43.70 %
Y B03.090.008A 2RPV-W18 08/09/1993 REC 43.70 %
Y B03.100.005 2RPV-W15 08/09/1993 REC 87.70 %
Y B03.100.006 2RP /-W16 08/09/1993 REC 87.70 %
Y B03.100.007 2RPV-W17 08/09/1993 REC 87.70 %
Y B03.100 008 2RPV-W18 08/09/1993 REC 87.70 %
Y B03.140.001 2SGA-INLET 12/19/1994 CLR N
B03.140.002 2SGA-OUTLET 12/19/1994 CLR N
B05.010.005 2RPV-W15-SE 08/09/1993 REC Y
q DUKE POb.H COMPANY OUALITY ASSURANCE TECHNICAL SERVICES In-Service inspection Database Managernent System Run D McGuire Unit 2 Inservice inspection Listing Page 2 Plant: McGuire Unit 2 Werval 2 Mage 1 04/05/1995 ITEM NUMBER ID NUMBER INSP DATE INSP STATUS INSP LIMITED GEO REF COMMENTS B05.010.005A 2RPV-W15-SE 08/09/1993 REC Y
B05.010.0058 2RPV-W15-SE 11/27/1994 CLR N
B05.010 006 2RPV-W16-SE 07/28'1993 CLR N
B05.010.006A 2RPV-W16-SE 07/28/1993 CLR N
B05.010.0068 2RPV-W16-SE 11/29/1994 CLR N
BOS 010.007 2RPV-W17-SE 07/28/1993 CLR N
B05.010.007A 2RPV-W17-SE 07/28/1993 CLR N
B05.010.007B 2RPV-W17-SE 11/30/1994 CLR N
B05.010.008 2RPV-W18-SE 08/09/1993 REC Y
B05.010.008A 2RPV-W18-SE 08/09/1993 REC N
B05.010.008B 2RPV-W18-SE 12/01/1994 CLR N
B05.070.001 2SGA-INLET-SE 12/05/1994 CLR 75.00 %
N B05.070.001 A 2SGA-INLET-SE 12/05/1994 CLR N
Q.
.. _ _ _ _ ~
~
_. _ _ =.....
h DUKE POWm OMPANY QUALITY ASSURANCE TECHNICAL SERVICES In-Service inspection Database Management System Run D WGuire Unit 2 Inservice inspection Listing Page 3 l
Plant: McGuire Unit 2 bierval2 Mage 1 1
g4,95/1995 ITEM NUMBER ID NUMBER INSP DATE INSP STATUS INSP t IMITED GEO REF COMMENTS B05.070.002 2SGA-OUTLET-SE 12/05/1994 CLR 75.00 %
N BOS 070.002A 2SGA-OUTLET-SE 12/05/1994 CLR N
i 805 130.001 2NC2F-1-1 08S4/1993 REC Y
B05.130.001 A 2NC2F-1-1 08/04/1993 REC N
B05.130.0018 2NC2F-1-1 11/27/1994 CLR N
B05.130.002 2NC2F-1-2 12/05/1994 CLR 75.00 %
N B05.130.002A 2NC2F-1-2 12/05/1994 CLR N
B05.130.003 2NC2F-1-3 12/05/1994 CLR 75.00 %
N B05.130.003A 2NC2F-1-3 12/05/1994 CLR N
B05.130.005 2NC2F-2-1 07/28/1993 CLR N
l B05.130.005A 2NC2F-2-1 07/28/1993 CLR N
805.130.005B 2NC2F-2-1 11/27/1994 CLR N
B05.130.009 2NC2F-3-1 07/28/1993 CLR N
o a
O DUKE POWt:R COMPANY QUALITY ASSURANCE TECHNICAL SERVICES in-Service inspection Database Management System Run D McGuire Unit 2 Inservice inspection Listing Page 4 Plant: McGuire Unit 2 hierval 2 Outage 1 04/05/1995 ITEM NUMBER ID NUMBER INSP DATE INSP STATUS INSP tiMITED GEO REF COMMENTS B05.130.009A 2NC2F-3-1 07/28/1993 CLR N
BOS 130.009B 2NC2F-3-1 11/30/1994 CLR N
Bes.130.013 2NC2F-4-1 08/04/1993 REC N
BOS 130.013A 2NC2F-4-1 08/04/1993 REC N
B05.130.0138 2NC2F 4-1 12/01/1994 CLR N
BC3 010 001 2RPV-6C4-32-01 12/13/1994 CLR N
B06.010.002 2RPV-664-32-02 12/13/194 CLR N
B06.010.003 2RPV-664-32-03 12/13/1994 CLR N
B06.010.004 2RPV-664-32-04 12/13/1994 CLR N
B06.010.005 2RPV-664-32-05 12/13/1994 CLR N
B06.010.006 2RPV-664 32-06 12/13/1994 CLR N
B06.010.007' 2RPV-664-32-07 12/13/1994 CLR N
B06.010.008 2RPV-664-32-08 12/13/1994 CLR N
ob e
O DUKE POW.rs COMPANY i
OUALITY ASSURANCE TECHNICAL SERVICES In-Service inspection Database Management System Run D McGuire Unit 2 Inservice inspection Listing Page 5 Plant: McGuire Unit 2 Intenal 2 Nage 1 04/05/1995 ITEM NUMBER 10 NUMBER INSP DATE INSP STATUS INSP tlMITED GEO REF COMMENTS B06.010.009 2RPV-664-32-09 12/13/1994 CLR N
BC3.030.001 2RPV-664-31 -01 12/09/1994 CLR N
BCS.030.001 A 2RPV-664-31 -01 12/13/1994 CLR N
B06.030.002 2RPV-664-31 -02 12/09/1994 CLR N
B06.030.002A 2RPV-664-31-02 12/13/1994 CLR N
B06.030 003 2RPV-664-31-03 12/09/1994 CLR N
B06.030.003A 2RPV-664G1-03 12/13/1994 CLR N
B06.030.004 2RPV-664-3104 12/09/1994 CLR N
B06.030.004A 2RPV-664-31-04 12/13/1994 CLR N
B06.030.005 2RPV-664-31-05 12/09/1994 CLR N
B06.030.005A 2RPV-664-31-05 12/13/1994 CLR N
B06.030.006 2RPV-664-31-06 12/09/1994 CLR N
B06.030.006A 2RPV-664-31-06 12/13/1994 CLR N
i
O O
O DUKE POWER COMPANY OUALITY ASSURANCE TECHN6 CAL SERVICES in Service inspection Database Management System Run D McGuire Unit 2 Inservice inspection Listing Plant: McGuire Unit 2 Interval 2 Outage 1 Page 6 04S5/1995 ITEM NUMBER ID NUMBER INSP DATE INSP STATUS INSP t IMITED GEO REF COMMENTS B06.030.007 2RPV-664-31-07 12/09/1994 CLR N
BCS 030 007A 2RPV-664-31-07 12/13/1994 CLR N
BCS 030 008 2RPV-664-31 -08 12/09/1994 CLR N
BC3.030.008A 2RPV-664-31-08 12/13/1994 CLR N
B06.030.009 2RPV-664-31-09 12/09/1994 CLR N
B06 030.009A 2RPV-664-31-09 12/13/1994 CLR N
B06.040.001 2RPV-THREAD-01 12/01/1994 CLR N
B06.040.002 2RPV-THREAD-02 12/01/1994 CLR N
B06.040.003 2RPV-THREAD-03 12/01/1994 CLR N
B06.040.004 2RPV-THREAD-04 12/01/1994 CLR N
B06.040.005 2RPV-THREAD-05 12/01/1994 CLR N
806.040.006 2RPV-THREAD-06 12/01/1994 CLR N
B06.040.007 2RPV-THREAD-07 12/01/1994 CLR N
1 x -.
~.
... -.-. -.~..
.. - - ~ _ _. ~......
9 o
O DUKE POWcR COMPANY OUALITY ASSURANCE TECHNICAL SERVICES in-Service inspection Database Management System Run n McGuire Unit 2 inservice inspection Listing Page 7 Plant: McGuire Unit 2 hierval 2 Outage 1 04/05/1995 ITEM NUMBER ID NUMBER INSP DATE INSP STATUS INSP LIMITED GEO REF COMMENTS B06.040.008 2RPV-THREAD-08 12/01/1994 CLR N
B06 040 009 2RPV-THREAD-09 12/01/1994 CLR N
B06 040 010 2RPV-THREAD-10 12/01/1994 CLR N
BCS.040.011 2RPV-THREAD-11 12/01/1994 CLR N
B06 040.012 2RPV-THREAD-12 12/01/1994 CLR N
B06 040 013 2RPV-THREAD-13 12/01/1994 CLR N
B06 040 014 2RPV-THREAD-14 12/01/1!PJ4 CLR N
B06.040.015 2RPV-THREAD-15 12/01/1994 CLR N
B06.040.016 2RPV-THREAD-16 12/01/1994 CLR N
i B06.040.017 2RPV-THREAD-17 12/01/1994 CLR N
l B06.040.018 2RPV-THREAD-18 12/01/1994 CLR N
B06.040.019 2RPV-THREAD-19 12/01/1994 CLR N
B06.040.020 2RPV-THREAD-20 12/01/1994 CLR N
DUKE POWcet COMPANY QUALITY ASSURANCE TECHNICAL SERVICES In-Service inspection Database Management System Run D McGuire Unit 2 inservice inspection Listing Page 8 Plant: McGuire Unit 2 Intonal2 Outage 1 04/05/1995 ITEM NUMBER ID NUMBER INSP DATE INSP STATUS INSP LIMITED GEO REF COMMENTS B06.040.021 2RPV THREAD-21 12/01/1994 CLR N
BCS 040.022 2RPV-THREAD-22 12/01/1994 CLR N
B06 040 023 2RPV-THREAD-23 12/01/1994 CLR N
B06.040.024 2RPV-THREAD-24 12/01/1994 CLR N
B06.040.025 2RPV-THREAD-25 12/01/1994 CLR N
BCS 040.026 2RPV-THREAD-26 12/01/1994 CLR N
BCS.040.027 2RPV-THREAD-27 12/01/1994 CLR N
B06.040.028 2RPV-THREAD-28 12/01/1994 CLR N
B06.040.029 2RPV-THREAD-29 12/01/1994 CLR N
B06.040.030 2RPV-THREAD-30 12/01/1994 CLR N
B06.040.031 2RPV-THREAD-31 1201/1994 CLR N
B06.040.032 2RPV-THREAD-32 12/01/1994 CLR N
B06.040.033 2RPV-THREAD-33 12/01/1994 CLR N
o 6
O DUKE POWER COMPANY OUALITY ASSURANCE TECHNICAL SERVICES In-Service inspection Database Management System Run D McGuire Unit 2 Inservice inspection Listing Page 9 Plant: McGuire Unit 2 Interval 2 Outage 1 04/05/1995 ITEM NUMBER ID NUMBER INSP DATE INSP STATUS INSP LIMITED GEO REF COMMENTS B06.040.034 2RPV-THREAD-34 12/01/1994 CLR N
B06.040.035 2RPV-THREAD-35 12/01/1994 CLR N
BOS 040 036 2RPV-THREAD-36 12/01/1994 CLR N
BCS.040.037 2RPV-THREAD-37 12/01/1994 CLR N
B06.040.038 2RPV-THREAD-38 12/01/1994 CLR N
BCS 040.039 2RPV-THREAD-39 12/01/1994 CLR N
BCS 040.040 2RPV-THREAD-40 12/01/1994 CLR N
. B06.040.041 2RPV-THREAD-41 12/01/1994 CLR N
BOG.040.042 2RPV-THREAD-42 12/01/1994 CLR N
B06.040.043 2RPV-THREAD-43 12/01/1994 CLR N
B06.040.044 2RPV-THREAD-44 12/01/1994 CLR N
B06.040.045' 2RPV-THREAD-45 12/01/1994 CLR N
B06.040.046 2RPV-THREAD-46 12/01/1994 CLR N
__m._.
o 6
O DUKE POWeH COMPANY QUALITY ASSURANCE TECHNICAL SERVICES In-Service inspection Database Managernent System Run D McGuire Unit 2 inservice inspection Listing Page 10 Plant: McGuire Unit 2 Werval 2 Mage 1 04/05/1995 ITEM NUMBER ID NUMBER INSP DATE INSP STATUS,. INSP tiMITED GEO REF COMMENTS B06.040.047 2RPV-THREAD 47 12/01/1994 CLR N
12/01/1994 CLR N
BCS 040 048
%r'V-THREAD-48 BCS 040 049 2RPV-THREAD-49 12/01/1994 CLR N
B03 040.050 2RPV-THREAD-50 12/01/1994 CLR N
B06.040 051 2RPV-THREAD-51 12/01/1994 CLR N
B06 040 052 2RPV-THREAD-52 12/01/1994 CLR N
Bc5 040 053 2RPV-THREAD-53 12/01/1994 CLR N
BC3.040.054 2RPV-THREAD-54 12/01/1994 CLR N
B06.050.001 2RPV-664-33-01 12/10/1994 CLR N
B06.050.002 2RPV464-33-02 12/10/1994 CLR N
B06.050.003 2RPV-664-33-03 12/10/1994 CLR N
B06.050.004 2RPV-664-33-04 12/10/1994 CLR N
B06.050.005 2RPV-664-33-05 12/10/1994 CLR N
c O
O DUKE POWcR COMPANY QUALITY ASSURANCE TECHNICAL SERVICES In-Service inspection Database Managernent System Run D McGuire Unit 2 Inservice inspection Listing Page 11 Plant: McGuire Unit 2 Interval 2 Mage 1 04/05/1995 ITEM NUMBER.
ID NUMBER INSP DATE INSP STATUS INSP LIMITEDGEO REF COMMENTS B06.050.006 2RPV-664 33-06 12/10/1994 CLR N
BCS 050.007 2RPV-664-33-07 12/10/1944
~ CLR N
B06 050 008 2RPV-664-33-08 12/10/1994 CLR N
B03.050.009 2RPV-664-33-09 12/10/1994 CLR N
B07.063.004 2RCP-2D-S 12/08/1994 REC N
B07.060 008 2RCP-20-H 12/10/1994 CLR N
B07.070.004 2NC-27C 11/29/1994 CLR N
i 807.070.03')
2ND-1B 12/09/1994 CLR N
B08.020.002 2PZR-W13A 12/07/1994 CLR N
B08.020.003 2PZR-W138 12/07/1994 CLR N
B08.020.004 2PZR-W13C 12/07/1994 CLR N
B08.020.005 2PZR-W13D 12/07/1994 CLR N
B09.011.001 2NC2F-1-4 12/14/1994 CLR N
_.=m..
m.___
m qCOMPANY O
c DUKE POWt OUALITY ASSURANCE TECHNICAL SERVICES In-Service inspection Database Management System Run D McGuire Unit 2 inservice inspection Listing Page 12 Plant: McGuire Unit 2 Interval 2 Outage 1 04/05/1995 ITEM NUMBER ID NUMBER INSP DATE INSP STATUS INSP LIMITEO GEO REF COMMENTS B09.011.001 A 2NC2F-1-4 12/05/1994 CLR N
B09.011.008 2NC2F-2-7 11/29/1994 CLR N
B09.011.008A 2NC2F-2-7 11/29/1994 CLR N
B09.011.019 2NC2FW53-1
~
12/15/1994 CLR N
B09.011.019A 2NC2FW53-1 12/13/1994 CLR N
B09 011020 2NC2FW53-2 12/15/1994 REC Y
B09 011020A 2NC2FW53-2 12/13/1994 CLR N
B09.011.021 2NC2FW53-7 12/15/1994 CLR N
B09.011.021 A 2NC2FW53-7 12/13/1994 CLR N
B09.011.022 2NC2FW53-8 12/15/1994 REC Y
B09.011.022A 2NC2FW53-8 12/13/1994 CLR N
B09.011.023 2NC2FW53-9 12/15/1994 REC Y
B09.011.023A 2NC2FW53-9 12/13/1994 CLR N
. ~... - _.. ~.
[
DUKE POb COMPANY QUALITY ASSURANCE TECHNICAL SERVICES In-Service inspection Database Management System Run D McGuire Unit 2 Inservice inspection Listing Page 13 Plant: McGuire Unit 2 bierval 2 Mage 1 04/05/1995 ITEM NUMBER ID NUMBER INSP DALE INSP STATUS INSP LIMITED GEO REF COMMENTS B09.011.024 2NC2FW53-10 12/15/1994 CLR N
B09 011.024A 2NC2FW53-10 12/13/1994 CLR N
B09 011.027 2NC2FW53-16 12/15/1994 REC Y
B01011.027A 2NC2FW53-16 12/13/1994 CLR N
B09.011.100 2ND2F-1 12XI7/1994 REC Y
B09.011.100A 2ND2F-1 12/05/1994 CLR N
B09 011.101 2ND2F-3 12/07/1994 CLR N
B09.011.101 A 2ND2F-3 12/05/1994 CLR N
B09.011.154 2N12F425 12/09/1994 CLR N
B09.011.154A 2Nt2F425 12/08/1994 CLR N
BC2.011.155 2N12F428 12/09/1994 REC Y
B09.011.155A 2Nt2F428 12/14/1994 CLR N
B09.011.156 2N12F439 12/09/1994 CLR N
.m m....._.
p A
DUKE POW COMPANY OUALITY ASSURANCE TEC!lNICAL SERVICES In-Service inspection Database Management System Run D McGuire Unit 2 Inservice inspection Listing Page 14 Plant: McGuire Unit 2 Interval 2 Outage 1 04/05/1995 ITEM NUMBER ID NUMBER INSP DATE INSP STATUS INSP LIMITED GEO REF COMMENTS B09.011.156A 2N12F439 12/21/1994
.CLR N
B09.021.003 2NC2FW26-1 12/01/1994 CLR N
B09.021004 2NC2FW26-3 12/01/1994 CLR N
B09.021.005 2NC2FW26-5 12/01/1994 CLR N
B09.021.006 2NC2FW26-8 12/12/1994 CLR N
B09.031.002 2NC22-WN4 11/29/1994 CLR 49.80%
N B09.031.002A 2NC22-WN4 11/29/1994 CLR N
B09.031.003 2NC22-WN8 12/05/1994 CLR 50.00 %
B09.031.003A 2NC22-WN8 12/07/1994 CLR N
B09.032.001 2NC26-WN6A 12/06/1994 CLR N
B09.032.002 2NC47-WN7A 12/06/1994 CLR N
B09.032.003' 2NC39-WN2 12/01/1994 CLR N
B09.032.004 2NC47-WN8 12/06/1994 CLR N
o O
O DUKE POL, a; COMPANY OUALITY ASSURANCE TECMAL SERVICES In-Service inspection Database Management System Run D McGuire Unit 2 Inservice inspection Listing Page 15 Plant: McGuire Unit 2 Interval 2 Outage 1 04/05/1995 ITEM NUMBER ID NUMBER INSP DATE INSP STATUS INSP LIMITED GEO REF COMMENTS B09.032.005 2NC39-WN10 12/07/1994 CLR N
B09.032.006 2NC2FW53-3 12/13/1994 CLR N
B09.032.007 2NC2FW53-20 12/13/1994 CLR N
B09.032.008 2NC2FW53-32 12/13/1994 CLR-N B09.040.008 2NC2FW47-13 12/06/1994 CLR N
B09.040.009 2NC2FW47-14 12/06/1994 CLR
-~
N B09.040.010 2NC2FW47-15 12/06/1994 CLR N
t B09.040.011 2NC2FW48-14 12/06/1994 CLR N
B09.040.012 2NC2FW48-17 12/06/1994 CLR N
B09.040.013 2NC2FW48-19 12/06/1994 CLR N
B09.040.014 2NC2FW48-21 12/06/1994 CLR N
B09.040.016 2NC2FW39-2 12/12/1994 CLR N
B09.040.065 2N12FW26-21 12/07/1994 CLR N
... - - - -.. _. ~..-
o O
O DUKE POWER COMPANY QUALITY ASSURANCE TECHNICAL SERVICFC.
in-Service inspection Database Management Splem Run D McGuire Unit 2 Inservice inspection Listin'J Page 16 Plant: McGuire Unit 2 bierval 2 Outage '
04/05/1995 ITEM NUMBER ID NUMBER INSP DATE INSP STATUS INSP LIMITED GEO REF COMMENTS B09.040.066 2N12FW57-1 12/07/1994 CLR N
B09.040.067 2N12FW57-7 12/07/1994 CLR N
B09.040.109 2NV2FW102-10 12/06/1994 CLR N
B09.040.110 2NV2FW102-11 12/06/1994 CLR N
B09.040.111 2NV2FW102-18 12/06/1994 CLR N
B09.040.120 2NV2FW255-15 12/13/1994 CLR N
B09.040.121 2NV2FW255-4 12/07/1994 CLR N
B09.040.123 2NV2FW264-18 12/07/1994 CLR N
B09.040.125 2NV2FW275-20 12/07/1994 CLR N
B09.040.127 2NV2FW282-25 12/07/1994 CLR N
i B09.040.128 2NV2FW282-4 12/07/1994 CLR N
B12.050.004G 2NI-93 12/20/1994 CLR N
B12.050.007D 2NI-160 12/14/1995 REC N
I
__m
._____m I
f~>')
f%
-k s
DUKE POWC COMPANY OUALITY ASSURANCE TECHNICAL SERVICES In-Service inspection Detabase Manage;nent System Run D McGuire Unit 2 Inservice inspeciton Listing Page 17 Plant: McGuire Unit 2 hterval 2 Ou!=ce :
04/05/1995 ITEM NUMBER ID NUMBER INSP DATE INSP STATUS INSP LIMITEDGEO REF COMMENTS B13.010.001 2RPV-INTERIOR 12/22/1994 REC N
014.010.017 2RPV-CRDM-71 12/21/1994 CLR N
C01.010.001 2SGA-03-04A 12/13/1994 REC Y
~
C01.010.070 2SWHX-BSH-BFLG 12/19/1994 CLR N
C01.020.090 2RCPSS-SH-3 08/11/1994 CLR N
C01.020 091 2RCPSS-SH-2 08/11/1994 CLR N
C01.030.001 2SGA-02-03 12/13/1994 CLR N
CO2.011.001 2RCPSS-INLET 08/08/1994 CLR N
CO2.011.002 2RCPSS-OUTLET 08/08/1994 CLR N
CO2.021.002 2SGA-SB-02 12/12/1994 CLR N
- CO2.021.002A 2SGA-SB-02 12/05/1994 CLR N
CO2.022.002 2SGA-SB-02 12/14/1994 CLR 84.30 %
N C03.010.001 2RHRHX-2A-SUPP 08/10/1994 CLR N
o 9 COMPANY O
-L DUKE POWe QUALITY ASSURANCE TECHNICAL SERVICES in-Service inspection Database Management System Run D McGuire Unit 2 Inservice Inspection Listing Page 18 Plant: McGuire Unit 2 Interval 2 Nage 1 04/05/1995 ITEM NUMBER ID NUMBER INSP DATE INSP STATUS INSP LIMITED GEO REF COMMENTS C03.010.002 2SWHX-SUPP 08/10/1994 CLR N
C05.011.004 2ND2FW17-22 08/15/1994 CLR N
C05.011.004A 2ND2FW17-22 08/08/1994 CLR N
C05 011.005 2ND2FW20-13 08/15/1994 CLR N
C05.011.005A 2NO2'FW20-13 08/08/1994 CLR N
C05.011.012 2ND2F-201 08/09/1994 CLR N
C05.011.012A 2ND2F-201 08/09/1994 CLR N
C05.011.013 2NDP106-1 08/09/1994 CLR N
C05.011.013A 2NDP106-1 08/09/1994 CLR N
C05.011.037 2ND2FW16-14 08/09/1994 CLR N
C05.011.037A 2NO2FW16-14 09/22/1994 CLR N
C05.011.101 2Nt2F422 12/09/1994 REC Y
C05.011.101 A 2N12F422 12/13/1994 CLR N
m m.
. _ ~. _..
O O
O DUKE PON_d COMPANY OUALITY ASSURANCE TECHNICAL SERVICES In-Service inspection Detebase Management System Run D McGuire Unit 2 inservice inspection Listing Page 19 Plant: McGuire Unit 2 Interval 2 Outage 1 0445/1995 ITEM NUMBER ID NUMBER INSP DATE INSP ST ATUS INSP LIMITED GEO REF COMMENTS C05.011.105 2Nt2F441 12/09/1994
,CLR N
C05.011.105A 2N12F441 12/13/1994 CLR N
C05.011.107 2NI2F448 12/09/1994 REC Y
C05.011.107A 2NI2F448 12/13/1994 CLR N
C05.011.109 2NI2F450 12/09/1994 CLR N
C05.011.109A 2N12F450 12/13/1994 CLR N
C05 011.110 2N12F461 12/07/1994 REC Y
C05.011.110A 2N12F461 12/05/1994 CLR N
C05.011.112 2N12F464 12/07/1994 CLR N
C05.011.112A 2N12F464 12/05/1994 CLR N
C05.011.113 2N12F465 1227/1994 REC Y
l C05.011.11:iA 2N12F465 12/05/1994 CLR N
C05.011.114 2N12F467 12/07/1994 REC Y
i
.m m.
O O
O DUKE POWert COMPANY OUALITY ASSURANCE TECHNICAL SERVICES In-Service inspection Database 2magement System Run D McGuire Unit 2 loser fce inspection Listing Page 20 Plant: McGuire Unit 2 hierva' 2 Mage 1 04/05/1995 ITEM NUMBER ID NUMBER INSP DATE INSP STATUS INSP LIMITED GEO REF COMMENTS C05.011.114A 2N12F467 12/05/1994 CLR N
C05.011.117 2N12F470 12A)7/1994 CLR N
C05.011.117A 2N12F470 12/05/1994 CLR N
C05.011.132 2NI2F417 12/09/1994 CLR N
C05.C11.132A 2N12F417 12/13/1994 CLR N
C05.011.133 2N12F420 12/09/1994 CLR N
C05.011.133A 2N12F420 12/13/1994 CLR N
C05.011.134 2N12F457 12/09/1994 CLR N
C05.011.134A 2N12F457 12/13/1994 CLR N
C05.011.140 2N12FW111-1 12/19/1994 REC Y
C05.011.140A 2N12FW111-1 12/19/1994 CLR N
C05.012.005 2ND2F-201L 08/09/1994 CLR N
C05.012.005A 2ND2F-201L 08/09/1994 CLR N
. -.. - - _ ~..
-. - =. - -
o O
O DUKE POWT.'d COMPANY OUALITY ASSURANCE TECHNICAL SERVICES In-Service inspection Database Management System Run D McGuire Unit 2 Inservice inspection Listing Page 21 Plant: McGuire Unit 2 Intenal 2 Mage 1 04M5/1995 ITEM NUMBER ID NUMBER INSP DATE INSP STATUS INSP LIMITED GEO REF COMMENTS C05.012.006 2NDP106-1L 08/09/1994 CLR N
COS 012.006A 2NDP106-1L 08/09/1994
'CLR N
+
C05.012.032 2ND2FW16-14L 08/09/1994 CLR N
C05.012.032A 2ND2FW16-14L 08/09/1994 CLR N
C05.012.034 2ND2FW17-22L 08/15/1994 CLR N
C05.012.034A 2ND2FW17-22L 0808/1994 CLR N
C05.012.035 2ND2FW20-13L 08/15/1994 CLR N
C05.012.035A 2NO2FW20-13L 08/08/1994 CLR N
C05.021.001 2N12FW108-8 12/13/1994 CLR N
C05.021.001 A 2N12FW108-8 12/14/1994 CLR N
C05.021.007 2N12F519 12/13/1994 CLR N
C05.021.007A 2N12F519 12/14/1994 CLR N
C05.021.013 2N12FW25-17 12/13/1994 CLR N
DUKE POWER COMPANY OUALITY ASSURANCE TECHNICAL SERVICES in-Service inspection Database Management System Run D McGuire Unit 2 Inservice Inspection Listing Page 22 Plant: McGuire Unit 2 Intona12 Mage 1 04/05/1995 ITEM NUMBER ID NUMBER INSP DATE INSP STATUS INSP LIMITED GEO REF COMMENTS C05.021.013A 2N12FW25-17 12/14/1994 CLR N
C05.021.019
' 2 NIP 18-1 08/08/1994 CLR N
C05.021.019A 2 NIP 18-1 08/09/1994 CLR N
C05.021.053 2NV2FW178-79 12/20/1994 CLR N
C05.021.053A 2NV2FW178-79 12/21/1994 CLR N
C05 021.059 2NV2F-23 08/15/1994 CLR N
C05 021.059A 2NV2F-23 08/08/1994 CLR N
C05.021.065 2NV2FW150-31 0809/1994 CLR N
C05.021.065A 2NV2FW150-31 08/09/1994 CLR N
C05.021.071 2NV2FW26-20 12/13/1994 CLR N
C05.021.071 A 2NV2FW26-20 12/13/1994 CLR N
C05.021.077A 2RCHP-OUT 12/27/1994 CLR N
C05.021.083 2NV2FW180-48 08/08/1994 CLR N
_m DUKE POWER COMPANY QUAUTY ASSURANCE TECHNICAL SERVICES In-Service inspection Database Management System Run D McGuire Unit 2 Inservice inspection Listing Page 23 Plant: McGuire Unit 2 Interval 2 Outage 1 04.95/1995 ITEM NUMBER ID NUMBER INSP DATE INSP STATUS INSP tIMITED GEO REF COMMENTS C05.021.083A 2NV2FW180-48 08/08/1994 CLR N
COS 021.089 2NV2F-4 08/15/1994 CLR N
i C05.021.089A 2NV2F-4 08/08/1994 CLR N
~
C05.021.095 2NV2FW208-21 08/15/1994 CLR N
C05.021.095A 2NV2FW208-21 08/08/1994 CLR N
COS.022.002 2NV2FW178-79L 12/20/1994 CLR N
C05.022.002A 2NV2FW178-79L 12/21/1994 CLR N
C05.022.005 2NV2FW180-48L 08/08/1994 CLR N
C05.022.005A 2NV2FW180-48L 08/08/1994 CLR N
C05.030.001 2N12F-170 08/09/1994 CLR N
C05.030.007 2N12FW122-2 12/12/1994 CLR N
C05.030.013 2N12FW62-19 08/10/1994 CLR N
C05.030.054 2NV2FW111-6 12/07/1994 CLR N
o O
O DUKE POWed COMPANY OUALITY ASSURANCE TECHNICAL SERVICES In-Service inspection Database Management System Run D McGuire Unit 2 inservice inspection *dth:
Page 24 Plant: McGuire Unit 2 Interval 2 Outage 1 04/05/1995 ITEM NUMBER 10 NUMBER INSP DATE INSP STATUS INSP LIMITED GEO REF COMMENTS C05.030.060 2NV2FW179-22 08/08/1994 CLR N
C05.030.066 2NV2FW21-18 12/07/1994 CLR N
C05 030.072 2NV2FW24-42 12/07/1994 CLR N
C05.030.078 2NV2FW303-23 08/08/1994 CLR N
C05.030.084 2NV2FW33-16 08/08n994 CLR N
C05.041.001 2NO2FW16-24 08/OSn:N CLR N
C05.051.005 2CA2FW50-9 12/20/1994 REC Y
C05.051.005A 2CA2FW50-9 12/16/1994 CLR N
C05.051.006 2CA2FW51-16 12/20/1994 CLR N
C05.051.006A 2CA2FW51-16 12/16/1994 CLR N
C05.051.010 2CA2FW50-19 12/19/1994 CLR N
C05.051.010A 2CA21-WO-19 12/16/1994 CLR N
C05.051.059 2CF2FW13-1 12/12/1994 REC Y
~. -...
O O
O DUKE POWtri COMPANY QUALITY ASSURANCE TECHNICAL SERVICES In-Service inspection Database Management System Run D McGuire Unit 2 Inservice inspection Listing Page 25 Plant: McGuire Unit 2 interval 2 Mage 1 04/05/1995 ITEM NUMBER ID NUMBER INSP DATE INSP STATUS INSP LIMITED GEO REF COMMENTS C05.051.059A 2CF2FW13-1 11/29/1994 CLR N
C05.051060 2CF2FW13-12 12/13/1994 REC Y
C05 051.060A 2CF2FW13-12 12/01/1994 CLR N
C05.051.062 2CF2FW15-1 12/19/1994 REC Y
C05.051.062A 2CF2FW15-1 12/01/1994 CLR N
C05.051063 2CF2FW15-12 12/19/1994 REC Y
C05 051063A 2CF2FW15-12 12/01/1994 CLR N
C05.051.100 2RV2FW30-15 12/19/1994 CLR N
C05.051.100A 2RV2FW30-15 12/20/1994 CLR N
C05.051.202 2SM58-D 12/21/1994 CLR N
C05.051.202A 2SM58-D 12/19/1994 CLR N'
C05.051.206 2SMSA-D 12/21/1994 CLR N
C05.051.206A 2SMSA-D 12/20/1994 CLR N
.._ _..._..- m o
O O
DUKE POWhn COMPANY OUALITY ASSURANCE TECHNICAL SERVICES In-Service inspection Database Management System Run D McGuire Unit 2 inservice inspection Listing Page 26 Plant: McGuire Unit 2 Interval 2 Mage 1 04/05/1995 ITEM NUMBER ID NUMBER INSP DATE INSP STATUS INSP LIMITED GEO REF COMMENTS C05.051.213 2SM2F-20 12/15/1994 REC Y
C05.051.213A 2SM2F-20 12/12/1994 CLR N
C05 051.218 2SM2FW8-5 12/21/1994 CLR N
a COS 051.218A 2SM2FW8-5 12/20/1994 CLR N
C05.051.251 2SV2FW2-1 12/21/1994 REC Y
i C05.051.251 A 2SV2FW2-1 12/19/1994 CLR N
C05.052.004 2CA2FW50-9L 12/20/1994 CLR N
C05.052.004A 2CA2FW50-9L 12/16/1994 CLR N
C05.052.005 2CA2FW50-19L 12/19/1994 CLR N
C05.052.005A 2CA2FW50-19L 01/05/1995 CLR N
C05.052.'006' 2CA2FW51-16L 12/20/1994 CLR N
C05.052.006A 2CA2FW51-1 AL
.,e,1994 CLR N
C05.052.050 2CF2FW13-1L 12/12/1994 CLR N
_. _. =, -..
...... ~. -
o O
O DUKE POWert COMPANY OUALITY ASSURANCE TECHNICAL SERVICES In-Service inspection Database Management System 81un D McGuire Unit 2 inservice inspection Listing Page 27 Plant: McGuire Unit 2 Interval 2 Outage 1 04/05/1995 ITEM NUMBER 10 NUMBER INSP DATE INSP STATUS INSP LIMITED GEO REF COMMENTS C05.052.050A 2CF2FW13-1L 11/29/1994 CLR N
C05.052.051
' 2CF2FW13-12L 12/13/1994 CLR N
C05.052.051 A 2CF2FW13-12L 12/01/1994 CLR N
C05.052.054 2CF2FW15-1L 12/19/1994 CLR N
- CF2FW15-1L 12/01/1994 CLR N
C05.052.054A 2
C05 052.055 2CF2FW15-12L 12/19/1994 CLR N
i C05 052 OSSA 2CF2FW15-12L 12/01/1994 CLR N
C05.052.100 2RV2FW30-15L 12/19/1994 CLR N
C05.052.100A 2RV2FW30-15L 12/20/1994 CLR N
C05.052.201 2SM2F-20L 12/15/1994 CLR N
C05.052.201 A 2SM2F-20L 12/12/1994 CLR N
C06.020.003'A 2NV-237-1 08/08/1994 CLR N
C06.020.0038 2NV-237-2 08/08/1994 REC N
..m
O O
O DUKE PO%.rt COMPANY QUALITY ASSURANCE TECHNICAL SERVICES In-Service inspection Database Management System Run D McGuire Unit 2 Inservice inspection Listing Page 28 Plant: McGuire Unit 2 Interval 2 Outage 1 04/05/1995 ITEM NUMBER IDNUMBER INSP DATE INSP STATUS INSP LIMITED GEO REF COMMENTS D02.020,021 2MCA-KC 3328 11/16/1994 CLR N
F01.010.001 C 2MCR-NC-4500 12/27/1994 REC N
F01.010.006C 2MCR-NC-4253 12/27/1994 REC N
F01.010.007C 2MCR-NC-4254 12/27/1994 CLR N
F01.010.0148 2MCR-NC-4120 12/14/1995 CLR N
F01.010.016C 2MCR-NC-4100 12/13/1994 CLR N
F01.010.017C 2MCR-NC-4083 12/14/1995 CLR N
F01.010.019A 2MCR-NC-4093 12/28/1994 CLR N
F01.010.076A 2MCR-NI-4949 12/02/1994 CLR N
F01.010.077C 2MCR-NI-4943 12/22/1994 CLR N
F01.010.078A 2MCR-NI-4654 12/14/1994 CLR N
F01.020.003A 2MCA-CA-H15 12/03/1994 REC N
F01.020.006C 2MCR-CA-H9t 12/22/1994 CLR N
O O
O DUKE POWm.rt COMPANY QUALITY ASSURANCETECHNICALSERVICES In-Service inspection Database Management System Run D McGuire Unit 2 inservice inspection Listing Page 29 Plant: McGuire Unit 2 htenal 2 Mage 1 04/05/1995 ITEM NUMBER ID N MBER INSP DATE INSP STATUS INSP LIMITED GEO REF COMMENTS F01.020.100C 2MCA-ND-5204 12,51/1994 REC N
F01.020. In ' C 2MCA-ND-5211 12/01/1994 CLR N
F01.020.102A 2MCA-ND-5307 12/0i/1994 REC N
~
F01.020.103C 2MCA-ND-5311 12/16/1994 CLR N
F01.020.158B 2MCR-NI-4821 12/02/1994 CLR N
F01.020.159B 2MCR-Ni-4825 12/02/1994 CLR N
F01.020.160A 2MCR-Ni-4787 12/02/1994 CLR N
F01.020.161 A 2MCR-NI-4772 12/16/1994 CLR N
F01.020.1688 2MCR-NI-4899 12/16/1994 CLR N
F01.020.169C 2MCR-NI-4896 12/16/1994 CLR N
F01.020.170A 2MCR-NI-4892 12/21/1994 CLR N
1 F01.020.171C 2MCR-NI-4134 12/16/1994 CLR N
F01.020.175B 2MCA-NI-5036 11/16/1994 CLR N
I
O O
O DUKE POhd COMPANY QUALITY ASSURANCE TECHN0 CAL SERVICES In-Service inspection Database Management System Run D McGuire Unit 2 Inservice Inspection Listing Page 30 Plant: McGuire Unit 2 hierval 2 Mage 1 04/05/1995 ITEM NUMBER ID NUMBER INSP DATE INSP STATUS INSP LIMITED GEO REF COMMENTS F01.020.1768 2MCA-NI-5718 12/01/1994 CLR N
F01.020.177A 2MCA-NI-5207 11/16/1994 CLR N
F01.020.1788 2MCA-NI-5806 11/16/1994 CLR N
F01.020.202B 2MCR-NS-4515 12/06/1994 CLR N
F01.020.203B 2MCR-NS-4566 12/06/1994 CLR N
F01.020 204B 2MCR-NS-4551 12/06/1994 REC N
F01.020 2058 2MCR-NS-4555 12/06/1994 CLR N
F01.020.432C 2MCA-SM-H24 -
12/12/1994 CLR N
F01.020.439C 2MCA-SM-H69 12/03/1994 CLR N
F01.020.5008 2MCR-VO4544 12,1)6/1994 CLR N
F01.020.503C 2MCR-VO-4507 12,1)6/1994 CLR N
FG1.020.525B 2MCR-WL-4061 12/06/1994 REC N
F01.030.001B.
2MCA-CA-5160 11/16/1994 CLR N
i
. -.. ~ - ~ _.
~
.. ~
O O
O DUKE POW. COMPANY QUALITY ASSURANCE TECt#NCAL SERVICES i
in-Service inspection Database it +;:..e..t System Run D McGuire Unit 2 Inservice inspection Listing Page 31 Plant: McGuire Unit 2 hierval 2 Nage 1 04/05/1995 ITEM NUMBER ID NUMBER INSP DATE INSP STATUS INSP LIMITED GEO REF COMMENTS F01.030.002A 2MCA-CA-5210 11/16/1994 CLR N
F01.030.004C 2MCA-CA-5461 11/15/1994 REC N
F01.030.018C 2MCA-CA-H170 12/03/1994 CLR N
~
F01.030.050A 2MCR-KC-4022 12/02/1994 CLR N
F01.030.051C 2MCR-KC-4557 12/16/1994 CLR N
F01.030.052A 2MCR-KC-4054 12/02/1994 CLR N
F01.030.053A 2MCR-KC-4057 12/02/1994 CLR N
F01.030.054B 2MCR-KC-4503 12/02/1994 CLR N
F01.030.055A 2MCA-KC-3327 11/16/1994 CLR N
F01.030.056A 2MCA-KC-3328 11/16/1994 CLR N
F01.030.061A 2MCA-KC-3285 11/16/1994 CLR N
F01.040.002 2PZR-LUGS 12/02/1994 CLR N
F01.040.008 2NSP-SUP-2A 12/05/1994 CLR N
i
O O
O DUKE POWtd COMPANY QUALITY ASSURANCE TECHNICAL SERVICES In-Service inspection Database Management System Run D McGuire Unit 2 Inservice inspection Listing Page 32 Plant: McGuire. Unit 2 Interval 2 Mage 1 04/05/1995 ITEM NUMBER ID NUMBER INSP DATE INSP STATUS INSP tIMITED GEO REF COMMENTS F01.040.009 2NS-HX-SUP-2A 12/02/1994 CLR N
F01.040.010 2 REG-HX-SUP 12/07/1994 CLR N
F01.040 011 2EXLD-HX-SUP 12/01/1994 CLR N
F01.040.015 2SW-HX-SUP
~
12/02/1994 CLR N
G01.001.002 2RCP-28 12/06/1994 CLR N
G01.001.004 2RCP-2D 12/15/1994 CLR N
G03.001.001 2NC2FW16-1 11/30/1994 CLR N
G03.001.001 A 2NC2FW16-1 12m1/1994 CLR N
G04.001.004 2SGD-CF-MOD 12/17/1994 CLR N
B 4
a+A 4
3._.
u i
f~
B.
Items examined by Pressure Testing i
~
Item Number ASME Section XI Tables IWB-2500-1
=
(Class 1),
t IWC-2500-1 (Class 2) 4 j.
Drawing Number Number of the Flow Diagram
=
i i
Examination Date Latest Examination date
=
Condition Partial or Complete test
=
Status Clear, Recordable or Reportable i
=
d Comments General and/or Detail Description
=
l 4
O I
u O
Refueling Outage Report Page 2 McGuire Unit 2 Revision 0 Section 5 January 23,1995
-. ~.
_ -- _. ~ __ _ _. ~
O O
O PAGE NO. I ticGUIRE UNIT NUtBER 2-2nd pfTERVAL 04A)S95 CLASS A (CATEGORY B-P) LEAKAGE TEST RESULTS ITEM NUMBER: B15.050.001 OUTAGE NUMBER EXAlWNATION DATE STATUS:
RESULTS EOC#9 01/08/95 COMPLETE RECORDABLE EOC # 10
//
N/A NOT TESTED EOC # 11
//
N/A NOT TESTED l
EOC # 12
//
N/A NOT TESTED EOC # 13
//
N/A NOT TESTED EOC # 14
//
N/A NOT REQUIRED EOC # 15
//
N/A NOTTESTED
.. _. _ _... _.. _. ~. _ _. _ _ _ _ _ _ - _. _ - _. _. _.. - _ _.. _. _ _ _ _.... _ _ _. _ -. - _.. - _ _.
o O
O i
NO.1 IIcGUREUMTNURSER2 2ndOfTERVAL 044545 CLASS B(CATEGORY C H)RESULTS THROUGH OUTAGE NUISER 9 IST PERIOD 2fG PEMOD 3RD PEfuoD EXAIA.
EXAli.
EXAIL ITEM NR.
DRA M DATE STATUS RESULTS DATE STATUS RESULTS DATE STATUS-RESULTS C07.030.001 MCL-1554-5.0 10GSS4 COMPLETE CLEAR i/
NOT WA 1/
NOTTESTED MA REQUIRED C07.030.002 MCL-2554-2.0 10GGS4 COMPLETE CLEAR ii NOT TESTED WA
//
NOTTESTED N/A C07.030.003 MCL-2554-3.0 10G644 PARTIAL CLEAR i/
NOT TESTED WA
//
NOTTESTED WA f
C07.030.004 MCL-255M.1 10G684 PARTIAL CLEAR 1/
NOTTESTED WA
//
NOTTESTED MA C07.030.006 MCL 2561-1.0 10G644 PARTIAL CLEAR
//
NOTTESTED N/A
//
NOT TESTED WA C07.030.006 MCL-2562-1.0 10G684 COMPLETE CLEAR
//
NOT TESTED N/A fi NOT MA REQUIRED '
f C07.030.007 MCL-2562-2.0 014645 PARTIAL rn URDABLE ii NOT TESTED WA NOT TESTED N/A 007.030.008 MCL-2562-2.1 014685 PARTIAL CLEAR 11' NOTTESTED NfA
//
NOT TESTED WA C07.030.009 MCL-2562-3.0 10G644 PARTIAL CLEAR I/
NOTTESTED N/A
//
NOTTESTED N/A C07.030.012 MCL-2563-1.0 10/1994 PARTIAL CLEAR
//
NOT TESTED N/A
//
NOTTESTED MA C07A30.014 MCL-2565-1.1 01A15S5 COMPLETE CLEAR
//
NOT TESTED N/A-
//
NOT MA REQUIRED C07.030.015 MCL-2571-1A ~
12/22 S4 PARTIAL CLEAR
//
NOTTESTED' N/A
//
NOTTESTED N/A C07.030A16 MCL-2556-3.0 01AW95 COMPLETE CLEAR-
/i NOTTESTED WA i1 NOT NIA REQUEED C07A30.017 MCL-2572-I D '
01A38S5 PARTIAL Cl. EAR i/
NOT TESTED N/A I/
NOT MA REQUEED I
C07.030.018 MCL-2572-1.1 01A3045 COMPLETE RECORDABLE ii NOTTESTED WA
//
NOT NA REOURED C07.030.020 MCL-2572-3.0 01 Ales 5 COMPLETE CLEAR
//
NOT TESTED N/A I/
NOT N/A REQUIRED C07.030A21 MCL-IS99-22 11/JOS4 COMPLETE CLEAR I/
- NOT TESTED N/A
//
NOT N/A REOUIRED C
C07.030.022 MCL-2605-22 12m584 COMPLETE CLEAR
//
NOT TESTED N/A
//
NOT N/A REQUIRED
l O
0 O
j PE W.2 McGUNIEUMTEllSER2 2ndOfTERVAL 04 M 95 l
CLASS B(CATEGORY C41)RESULTS THROUGN OUTAGE NUISER 9 IST PElWOO 21e PERIOD 3RD PERIOD EXAtt EXAM.
EXAtt ITEM NB.
DRAWNG DATE STATUS RESULTS DATE STATUS RESULTS DATE STATUS RESULTS C07.030.023 MCL-2574-3.1 01 2 95 COMPLETE CLEAR
//
NOT TESTED N/A
//
NOT MA REQUIRED C07.030.024 MCL-2573 4.0 01 2 95 COMPLETE CLEAR
//
NOT TESTED MA
//
NOT MA REQUIRED C07.030.025 MCL-2574-4.0 01AW95 COMPLETED CLEAR
//
NOT TESTED MA
//
NOT MA REQUIRED C07.030.026 MCL-2500-1.0 01 2 95 COMPLETE RECORDABLE
//
NOTTESTED N/A
//
NOT MA REOUIRED C07.030.028 MCL-2591 1.1 01 2 95 PARTIAL CLEAR
//
NOT TESTED N/A
//
NOT N/A REOUIRED C07.030029 MCL-2593-1.0 01 2 95 COMPLETE RECORDABLE
//
NOT TESTED N/A
//
NOT MA REQUIRED C07.030030 MCL-2593-13 01 2 95 COMPLETE CLEAR
//
NOTTESTED N/A
//
NOT MA REQUIRED C07.030.031 MCL-2592-1.0 01 2 95 PARTIAL CLEAR
//
NOTTESTED N/A
//
NOT MA i
HEOUIRED C07.030.032 MCL-2593-12 10/1784 COMPLETE RECORDABLE
//
NOT TESTED N/A
//
NOT N/A REQUIRED C07.030.033 MCL-2005-13 12A35/94 COMPLETE CLEAR
//
NOT TESTED N/A
//
NOT N/A REQUIRED C07.030.034 MCL-2617-1.0 11/s 94 PARTIAL CLEAR
[I NOT TESTED - N/A
//
NOT MA REOUIRED C07.030035 MCL-2553-2.0 01 2 95 PARTIAL CLEAP
//
NOT TESTED N/A
//
NOTTESTED N/A C07.030.037 MCL4554-1.0 01 2 95 COMPLETE CLEAR
//
NOTTESTED N/A
//
NOTTESTED N/A C07.030.038 MCL-2554-1.1 01 2 95 COMPLETE RECORDA6LE
//
NOTTESTED N/A
//
NOTTESTED N/A C07.030.039 MCL-2554-12 01 2 95 PARTIAL CLEAR
//
NOT TESTED N/A
//
NOT TESTED N/A C07.030.040 MCL-2554-1.3.
01A38/95 COMPLETE CLEAR
//
NOT TESTED N/A
//
NOT TESTED N/A C07.030.041 MCL-2604-3.0 11 2 94 COMPLETE CLEAR
//
NOT TESTED N/A
//
NOT N/A REQUIRED
i O
O O
PAGE NO.3 m up5T DAMBER 2-W MTERVAL.
04 M 95 CLASS 8 (CATEGORY C4f)RESULTS THROUGH OUTAGE NUtBER 9 ISTPEfuoD 295 PERIOD 3RD PERIOD EXAK EXAK EXAK ITEM No.
DRAWING DATE STATUS RESULTS DATE STATUS.
RESULTS DATE STATUS RESULTS C07.030.042 MCL-1601-2.4 11/J094 COMPLETE CLEAR I/
NOT TESTED N/A
//
NOT N/A' REQUIRED i
C07.030.043 MCL-2605-1.16 12 m 94 COMPLETE CLEAR
//
NOT TESTED N/A 1/
NOT N/A REQUIRED l
W
O O
O PAGE NO.1 McGUIRE LMT NUtBER 2-2nd BfTERVAL 0405S5 CLASS C(CATEGORY D-A)RESULTS THROUGH OUTAGE MutBER 9 IST PERIOD 295 PEN 00 3RD PERICO EXAE EXAK EXAE ITEM NG.
DRAWING DATE STATUS RESULTS DATE STATUS RESULTS DATE STATUS DESULTS D01.011.001 MCL-1554-5.0 10/2684 COMPLETE CLEAR
//
NOT TESTED N/A
//
NOT MA REQUIRED D01D11.002 MCL-2554-3.1 10r2tW94 COMPLETE CLEAR
//
NOTTESTED N/A
//
NOTTESTED MA 001.011.003 MCL-2554-5.0 10GlW94 COMPLETE CLEAR
//
NOT TESTED N/A
//
NOT TESTED MA D01.011.004 MCL-2554-2.0 10d2tW94 COMPLETE CLEAR
//
NOT TESTED N/A
/i NOT MA REQUIRED i
I
.. ~. _ _ -.... _. _
~. -
O O
O l
PAGE NO.1 N UMT MNSER 2.W BGERVAL 04 m 95 CLASS C(CATEGORYD 8)RESULTS THROUGN OUTAGE MutBER 9 IST PEMOD 2ND PENOD 3RD PERIOD EXAK EXAK EXAK REIGND.
DRAWWIG DATE STATUS RESULTS DATE STATUS
.RESULTS DATE STATUS RESULTS 002.011.001 MCL-1574-1.0 10/1294 COMPLETE CLEAR
//
NOT TESTED N/A
//
NOT WA REQURED 002.011.002 MCL-1574-1.1 112844 COMPLETE CLEAR
//
NOT TESTED WA I/
NOT WA REQURED l
002.011.003 MCL-1574-2.0 10G094 00MPLETE CLEAR
//
NOT TESTED N/A
//
NOT WA REQUIRED D02.011.004 MCL-1574-3.0 114844 COMPLETE CLEAR II NOT TESTED WA
//
NOT WA REQUIRED D02.011.006 MCL-2573-1.1 1148S4 PARTIAL CLEAR
//
NOTTESTED WA II NOT N/A REOURED D02.011.007 MCL-2574-1.1 11AM/94 COMPLETE CLEAR
//
NOT TESTED WA
//
NOT WA REQUIRED D02.011.008 MCL-2574-2.1 10G094 COMPLETE CLEAR
//
NOT TESTED WA
//
NOT WA REQUIRED 4
002.011.009 MCL-2574-2.0 10G094 COMPLETE CLEAR 1/
NOT TESTED N/A
//
NOT WA REQUIRED 002211.010 MCL-2574-3.0 1128S4 COMPLETE CLEAR
//
NOT TESTED N/A
//
NOT WA REQUIRED 002.011.011 MCL-2574-3.1 1148S4 COMPLETE CLEAR
//
NOTTESTED N/A
//
NOT WA REQUIRED 002211213 MCL-2502-1.0 10/1854 PARTIAL RECORDABLE
//
NOTTESTED N/A
//
NOT N/A REQUIRED 002A11.014 MCL-2502-1.1 10f1884 COMPLETE CLEAR
//
NOTTESTED N/A
/t NOT N/A l
REQUIRED D02A11.015 MCL-2593-12 10/17/94 COMPLETE CLEAR II NOT TESTED N/A
//
NOT N/A REQUIRED D02A11A16 MCL-2009-1A 1141/94 COMPLETE CLEAR
//
NOTTESTED N/A
//
NOT WA REOURED D02.011.017 MCL-2609-1.1 11/14/94 PARTIAL CLEAR I/
NOT TESTED N/A
//
NOT WA REQUIRED
4 I
)
=
e "8
8 O
g r
9 o
o l
l l W
We W
m
-g,_ g
,s_ mg 4
s sm a m.
]
=
i
- na as II l
w c
o o o i niiis llg
=
s s
s s a
5' El li ig
=
i S
l I
m I
l n
e s s gi i
i e5 l
$$ lI Il
=
a s;
8 5
E
- l l ll i
- o, s,
s E
gl E iiil 4
m.
._ah..
-.4w_U.A.eL b.._m-m u
Aa.amabAJ-*..A-S-E 6
er a.e9,e.s.
&mmA.
3.m.M m-h.es me 4.%a4p.A.6enm_.g.e-4.4me.+ L u m 46 AaeL A4A 4.b hW-~
mbAeh 4.&4Dme.
-u.+-Mk m%6Ca.
Et 4t.
amwAm.
4
.hme u._a me4-..Am M&mh..
.m..,a_
b o
O PAGE NO.1 RicGUIREUMTMutBER2 2ndDiTERVAL N
CLASS C(CATEGORY DC)RESULTS THROUGH OUTAGE NUteER 9 ISTPERIOD l55 PERIOD 3RD PERIOD EXAK EXAE EXAK RElf NIL DRAWW4G DATE STATUS RESULTS DATE STATUS RESULTS DATE STATUS RESULTS D03.011.001 MCL-25701.0 11A294 PARTIAL CLEAR i/
NOT TESTED N/A
//
NOTTESTE9 M/A
l l
l m
5.2 T3mited Framinntions (Issa than 9(y7c Framinntion Coverasre)
(d A.
There were fifteen item numbers inspected for which the required 909c' or greater examination coverage was not obtained. These item numbers are listed below along with the Request for Relief Number that will be filed for these limited Inspections.
Item Number Request for Relief Serial Number B03.090.005A In the course of preparation B03.090.006A in the course of preparation B03.090.007A In the course of preparation B03.090.008A In the course of preparation B03.100.005 in the course of preparation B03.100.006 l
In the course of preparation i
B03.100.007 In the course of preparation B03.100.008 in the course of preparation B05.070.001 in the course of preparation B05.070.002 In the course of preparation B05.130.002 In the course of preparation B05.130.003 In the course of preparation B09.031.002 In the course of preparation B09.031.003 in the course of preparation O
c02.022.002 In the course of preparation l
l O Refueling Outage Report Page 3 McGuire Unit 2 Revision 0 Section 5 January 23,1995
i 6.0 t...:.-
No reportable indications were discovered during refueling outage 9.
i f
a O
i i
Refueling Outage Report Page1 McGuire Unit 2 Revision 0 Section 6 January 23,1995
O 7.0 Personnal Eauinment and Material CerdfienHons
\\-)
All personnel who performed or evaluated the results of inservice inspec-tions from August 31,1993 to January 12,1995 at McGuire 2 were certified in accordance with the requirements of 1989 Edition of ASME Section XI.
The appropriate certification records for each Duke Power Company inspector are on file at McGuire Nuclear Station or in the Carporate offices in Charlotte, North Carolina. The certification records for the Babcock &
Wilcox Nuclear Technologies inspectors are on file at the Babcock & Wilcox Nuclear Technologies offices in Lynchburg, Virginia.
Records of periodic calibration of Duke Power Company inspection equipment are on file at McGuire Nuclear Station or in the Corporate offices in Charlotte, North Carolina. The periodic calibration records for the Babcock & Wilcox Nuclear Technologies inspection equipment are on file at the Babcock & Wilcox Nuclear Technologies offices in Lynchburg, Virginia.
O f3 V
Refueling Outage Report Page'l McGuire Unit 2 Revision 0 Section 7 April 5,1995
" " * " ~ " =
O The following are the Problem Investigation Process reports (PIP's) issued to document reportable items found during Outage 9:
NONE i
O 4
i O
Refueling Outage Report Page1 McGuire Unit 2 Revision 0 Section 8 January 23,1995
__-___....____._.___._.a_,__-._.....
i i
llO The following reference documents apply to the inservice inspection l
performed during Outage 9 at McGuire Unit 2:
(1) Request for Relief (93-005) l l
(2) Electric System Support Duke Power Company McGuire Nuclear Station Unit II Reactor Vessel Lower Hemisphere to Shell Weld No: 2RPV-WOI i
(Manual) l l
/
i O
l l
1 l
l Refueling Outage Report Page1 McGuire Unit 2 Revision 0 Section 9 April 5,1995
J l
Serial No. No.93-005 1
DUKE POWER COMPANY 9
i Request for ReliefFrom i
Inservice Inspection Requirement i
i Station:
McGuire l
Umt:
2 1'
Requesting Department:
Nuclear Generation Department Reference Code:
1989 ASME Section XI, no addenda I.
Component for which exemption is requested:
i a.
Name and Identification Number:
Reactor Pressure Vessel outlet nozzle-to-vessel welds, and outlet nozzle-to-safe end, outlet nozzle safe end to Reactor Coolant System piping welds.
4 n
b.
Function:
Welded connection between the Reactor i
V Pressure Vessel and respective Reactor Coolant piping providing a flow path to the steam generator.
c.
ASME Section XI Code Class:
ASME Section XI, Class 1 d.
Construction Code and Class (If Applicable):
NA e.
Valve Category (If Applicable):
NA II.
Reference Code Requirement that has been determined to be impractical:
ASME Section XI, Table IWB-2500-1, Category B-D Item Numbers B3.90 and B3.100, Note 2; at least 25% but not more that 50% (credited) of the nozzles shall be eramined by the end of the first inspection period and the remainder by the end of the inspection interval.
ASME Section XI, IWB-2420(a):
The sequence of component examinations established during the first inspection interval shall be repeated during each successive inspection.
O r-
-v.,
r-a,--
e
-,,e,,,--,,-.<,,w------,ww--
,e
.c
-ans-,-a
i i
Serial No.93-005 O
111.
Basis for Requesting Relief; a
l During the first period of the first inspection interval at McGuire
~ Nuclear Station Unit 2, the 29" outlet nozzle-to-vessel welds, j
outlet nozzle to safe end welds, outlet nozzle safe end to Reactor Coolant System piping welds, were examined using Babcock &
Wilcox's Automated Reactor Inspection Tool (ARIS).
i The four nozzle welds examined for Unit 2 met the 50%
l requirement of Table IWB-2500-1 Category B-D (Note 2).
- No recordable indications were detected.
1 1
During the third period of the first ten year inspection interval all i
i Reactor Vessel nozzle-to-vessel and all respective nozzle-to-pipe i
welds were examined using automated inspection equipment.
i Included in this ernmination were the 29" outlet nozzle-to-vessel and nozzle-to-pipe welds examined during the first period. The re-examination of these 29" outlet nozzles were performed j
meeting the requirements of the 1989 ASME Section XI Code.
Credit will be applied to the second interval, first period requirement for the 29" outlet nozzle-to-vessel welds under Table i
IWB-2500-1, Category B-D, Items B3.90, B3.100. and Category B-i O F Items B5.1 and B5.1 These examinations will not be j
performed during the first period of the second inspection l
interval.
i IV.
Alternate Examination:
i i
Automated re-eramination of all the Reactor Vessel nozzle-to-vessel welds, including respective nozzle-to-pipe welds will be deferred to the last period of the second ten year inspection i
interval.
i Following this inspection sequence will provide assurance of the integrity of the nozzle-to-vessel and nozzle-to-pipe welds; and will j
not adversely affect the health and safety of the public.
l V.
Implementation Schedule:
l i
Examinations are currently scheduled to be performed during the j
third inspection period of the second ten year interval.
i Evaluated By:
bdaanbr Date 9///93 u
Reviewed By:
Date
/ D
//
l j
j
,q 10.0 Clana 1 and 2 Renales and Renlacements V
10.1 As required by ASME Section XI 1980 Edition, a record of the Class 1 and 2 Repairs and Replacements for work performed from August 31,1993 through February 28,1994 is provided and is included in this section of the report. The individual work request documents are on file at McGuire Nuclear Station.
]
10.2 As required by ASME Section XI 1989 Edition, a record (Form NIS-2) of the Class 1 and 2 Repairs and Replacements for work performed 4
from March 1,1994 to January 12,1995 is provided and is included 1
in this section of the report. The individual work request documents l
are on file at McGuire Nuclear Station.
l 1
l 1
lO e
i
)
i e
i 4
J O
aereeii, o etese aegert reae 1 McGuire Unit 2 Revision 0 Section 10 April 5,1995
i 4
4 McGuire 2 Listing of Work Order Numbers which include Class 1 & 2 Repairs and Replacements for work performed from August 31,1993 through j
February 28,1994.
j Work OrderNa i
92087271 Add check valves, NS system NSM-MG-223 93012023 Cut out & reorient valve 2SA-5 i
93021393 CT for NSM 22302 replace MSSV-(2A HDR) 93021812 CT for NSM 22305 replace MSSV-(2D HDR) 93027157 CT for NSM 22413 NV letdor n replacement 93016081 Repair 2MNVVA0457A l
93038746 Repair leak on Unit 2 Letdown Piping 93043785 NS piping system replacement per NSM-2 j
93004686 Inspect valve 2NI70 93012630 Remove / replace hangers on 2-NC-1 l
93059755 Inspection of valve 2NI-0093 1
{
Listing of Work Order Numbers which include Class 1 & 2 Form NIS-2, l
(Repair and Replacements) from March 1,1994 through January 12,1995.
- O l
Work Order Na 94027192 Replace snubber i
i i
5 1-l i
i i O e
4
ob FORM NIS-2 OWNER'S REPORT FOR EPAIR3 OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1.
Owner Duke Power Company 1a. Date
///7[W Address 422 S. Church St.. Chariotte NC 28201 Sheet 1
of 1 2.
Plant McGuire Nuclear Station Address 12700 Haaers Ferry Road. Huntersville NC 28078 2a. Unit O1 92 01 and 2 Shared 3.
Work Performed By Duke Power Company 3a.
Work Order #
9'/027/92 Address 422 S. Church St.. Charlotte NC 28201 Repair OJganization Job #
Type Code Symbol Stamp N/A Authorization No. N/6 Expiration Date N/A 3b.
NSM or MM #
A//A 4.
Identification of System N
5.
(a) Applicable Construction Code ASME lil 1971 Edition, Summer and Winter Addenda, NONE Code Cases (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1989. no Addenda 6.
Identification of Components Repaired or Replaced and Replacement Components Column 1 Column 2 Column 3 Col. 4 Column 5 Col 6 Column 7 Column 8 Name of Component Name of Manufacturer Manufacturer Serial National Other Identification Year
- Repaired, ASME Code Number Board Built Replaced, or Stamped Number Replacement (yes or no)
A
/p, Sp O Repaired EiD No y A, g/g ug og O Replacement O Yes
,2 inM -fs>- Si 75
%/ 2//W M Replaced B
4, g,x 0 Repaired fii3 No y p>
g A.
g df M Replacement O Yes
,2ma-S&C/15
~s,(q N9%
0 Replaced C
O Repaired O No O Replacement O Yes O Replaced D
0 Repaired O No O Replacement O Yes O Replaced E
O Repaired O No O Replacement O Yes O Replaced F
0 Repaired O No O Replacement O Yes O Replaced
Form NIS-2 (Back) g NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
7.
Description of Work fo7x*c2 he#at 8.
Test Conducted: Hydrostatic OPneumatic O Nominal Operating Pressure DOther O Exempt 0 Pressure osia Test Temp.
"F Pressure osia Test Temp.
F Pressure osia Test Temp.
F 9.
Remarks
- SmAtel, hcrN6 B"*
N 26&#"'"*' r (Applicable Manufacturers Data Reports to be attached)
CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this repair or replacement conforms to the rules of the ASME Code,Section XI.
Type Code Symbol Stamp N]A g/
Certificate of Authorir. tion No. N]A Expiration Date N/A Signed F L. Grass Jr / Tech Spec
\\
M Date /g
,19 #
Owner or Owners Designfe, Title CERTIFICATE OF INSERVICE INSPECTION l, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province of North Carolina and employed by HSBI and l Company of Hartford Connecticut have inspected the components described in this Owners Report during the period 7
/J'- 4 Y to // 9 V
, and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code,Section XI.
By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, conceming the examinaticas and corrective measures described in this Owner's Report.
Furthermore, neither the laspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.
[E Commissions AIR 7 Iobl/06 PST 4-e> ~ 7
~
I liis'if or's Signature Natiorial Board [ State,ProvinM and Endorsements Date
/ l-]
,19f_
6
..