ML20080J765

From kanterella
Jump to navigation Jump to search
Transmittal Letter Dated 8/3/2010-Request to Renew CoC No. 9269, Model No 650L
ML20080J765
Person / Time
Site: 07109269
Issue date: 08/03/2010
From: Podolak L
QSA Global
To:
Office of Nuclear Material Safety and Safeguards
NGSantos NMSS/DFM/STL 415.6999
References
Download: ML20080J765 (10)


Text

3 August 2010 ATTN: Document Control Desk Spent Fuel Project Office Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission 11555 Rockville Pike One White Flint Rockville, MD 20852 RE:

USA/9269/B(U)-96 (Current Revision 5)

Dear Director:

7/-9J09 QSA Global, Inc.

40 North Avenue Burlington, MA 01803 Telephone: (781) 272-2000 Toll Free: (800) 815-1383 Facsimile: (781) 273-2216 QSA Global, Inc. requests renewal of the certificate referenced above for the Model 650L Type B(U) container.

The current Type B(U) approval for the Model 650L package expires on 30 November 2010.

This submission is being made as an amendment in entirety replacing all previously submitted documentation in support of this approval. Enclosed with this letter is Revision 7 of the SAR, complete with all reference appendices and with updated descriptive drawings. This revision of the SAR has been formatted to comply with the recommended guidance in NUREG 1886 (Final-March 2009). Changes from Revision 6 to Revision 7 of the SAR

. are detailed in an enclosed SAR revision change table titled "Revision Description for the Model 650L _SAR from Revision 6 to* Revision 7". Changes in the enclosed drawings are described in a table included with this letter titled "Summary Table of Changes to Drawings R65006 Rev H to Rev J" At this time there are no further changes or modifications necessary to this Type Bapproval. Shohld you have any additional questions or wish to discuss this submission after receipt please feel free to contact me.

Sincerely, Lori Podolak Senior Regulatory Affairs Specialist Regulatory Affairs Department Ph: (781) 505-8241 Fax: (781) 359-9191.

Email: Lori.Podolak(fv,gsa-global.com Engineering Approval

Enclosures:

(I-Hard Copy Original and 6 CDs to the letter cc, each CD containing copies of the following Files):

cc:

Revision Description for the Model 650L SAR from Revision 6 to Revision 7 Summary Table of Changes to Drawings R6500\\Rev H to Rev J List of Affected Pages b 

-r>

650L SAR Revision 7

-'i:i iv,. \\JI v Mr. Eric Benner, Chief Division of Spent Fuel Storage and Transportation Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission 11555 Rockville Pike, Mailstop: EBB-3D-02M Rockville, MD 20852 w w w. qs a global. c om

Safety Analysis Report for the Model 650L Transport Package List of Affected Pages Revision 1, Replacement of Appendix A Index; Added Drawing R65006, 19 November, 1999 Revision F to Appendix A.

Revision 2, Replacement of Appendix A Index; Added Drawing R65006, 31 October, 2000 Revision G to Appendix A.

Revision 3, Reformatting of the SAR to cover compliance to IAEA TS-R-1 31 October 2005 and NRC guidance format. Addition of Se-75 as authorized nuclide.

Revision 4, 6 June Changes to Sections 1, 2, 5, 7 and 8 to address NRC RAI dated 31 2006 May 2006 Revision 5, 29 June Changes to pages 5-1, 5-2, 5-5, 5-6 and 7-1.

2006 Revision 6, 14 July Changes to pages 1-1, 5-1 and5-2.

2006 Revision 7, April SAR updated to reflect compliance to NUREG 1886 (Final Report 2010

-March 2009).

i

.4 i

Revision Description for the Model 650L SAR from Revision 6 to Revision 7 April 2010 Page 1 of 4 Revision 7to the 650L SAR reformats the SAR in accordance with the recommendations in NUREG 1886, "Joint Canada - United States Guide for Approval of Type B(U) and Fissile Material Transportation Packages" (Final Report - March 2009). Other than generic format revisions, SAR changes are listed under the SAR Section in Revision 7 where the change occurs.

Section Description Change Impact Action Taken By Reference Reported QSA Regarding Pursuant Affected Units to 71.95 Generic Removed regulatory section references under the No Such modifications do not change the original intent of the None. Not Format SAR section headers. This information is not sections affected, applicable.

Changes required under the recommended NUREG document.

Added SI values and units to all radiation, contamination, and activity references.

Made in document references to Section 2.12 appendices more generic (e.g., 2.12.1 now referenced as 2.12).

1.1 Statement added to indicate that this SAR is formatted in No Change added for completeness, no impact on the package None. Not accordance with NUREG-1886 "Joint Canada - United integrity or transport compliance, applicable.

States Guide for Approval of Type B(U) and Fissile Material Transportation Packages" dated March 2009.

1.2 Added detail. Revised maximum content weight to No No impact on the package integrity or transport compliance.

None. Not 1.2.2 include mass associated with the source capsule handling Detail added has no effect on the package center of gravity applicable.

wire assembles with a maximum shipment of two source or the maximum package mass as evaluated and tested assemblies for the package.

under TP 80 and the SAR.

1.2 Added detail to Package Description and a general No Change added for completeness, no impact on the package None. Not package drawing Figure 1.2.A.

integrity or transport compliance, applicable.

1.2.3 Added section per NUREG-1886 with notation that this No Change added for completeness and from guidance in None. Not section is Not Applicable to this package design.

NUREG-1886. No impact on the package integrity or applicable.

transport compliance.

1.3 Revised to add sketch of Model 650L prepared for No Change added for completeness and from guidance in None. Not transport as recommended under NUREG-1886.

NUREG-1886. No impact on the package integrity or applicable.

transport compliance.

1.1 References to Canadian Nuclear Safety Commission No Change added for completeness, no impact on the package None. Not 2.1.2 PTNS Regulations SOR/2000-208 added, integrity or transport compliance, applicable.

Revision Description for the Model 650L SAR from Revision 6 to Revision 7 April 2010 Page 2 of 4 Section Description Change Impact Action Taken By Reference Reported QSA Regarding Pursuant Affected Units to 71.95 2

Added reference to TS-R-1.

No Change added for completeness, no impact on the package None. Not integrity or transport compliance, applicable.

2.1.4 Subsections combined and consolidated. Criteria for No Such modifications do not change the original intent of the None. Not hardware and welding requirements noted specifically as sections affected.

applicable.

referenced on drawings in Appendix 1.3 2.2.1 Added elongation information. Expanded material No Change added for completeness, no impact on the package None. Not Table properties information for steel and stainless steel integrity or transport compliance, applicable.

2.2.A including references. Noted that Material properties for Hot and Cold Rolled Steel Sheet are "'Typical" based on ASTM references and included justification in note.

2.3.1 Description of QA Program basis added No Change added for completeness, no impact on the package None. Not integrity or transport compliance, applicable.

2.4.2 Relocated information related to tamper-indicating No Change made per guidance in NUREG-1886. No impact on None. Not feature (was previously located in Section 1.3.2 of SAR the package integrity or transport compliance, applicable.

Rev 6.

2.4.3 Added section titled "Positive Closure" which No Change made per guidance in NUREG-1886. No impact on None. Not incorporates some information previously stated in the package integrity or transport compliance, applicable.

different sections of the SAR. Additional detail related to securement of the source in the lock assembly is added.

2.6.1 Added detail on calculation and assumptions releated to No Change added for completeness and made per guidance in None. Not decay heat values. Added Table 2.6.A with Decay NUREG-1886. No impact on the package integrity or applicable.

Energy information for Type B nuclides transported in transport compliance.

the 650L.

2.6.1.1 Table reference updated.

No Formatting change.

None. Not

_applicable.

2.6.7 Removed information related to test equipment.

No No impact on the package integrity or transport compliance.

None. Not Conformance to test requirements was ensured at the applicable.

time of testing by the NRC approved QA program.

2.6.9 Section Title Revised per NUREG-1886.

No Change made per guidance in NUREG-1886. No impact on None. Not the package integrity or transport compliance, applicable.

Revision Description for the Model 650L SAR from Revision 6 to Revision 7 April 2010 Page 3 of 4 Section Description Change Impact Action Taken By Reference Reported QSA Regarding Pursuant Affected Units to 71.95 2.7.4.3 Detail added to Stress Calculations section to No Change added for completeness, no impact on the package None. Not demonstrate more clearly the source capsule's ability to integrity or transport compliance, applicable.

maintain containment under the Hypothetical Accident Condition Thermal testing.

2.8 Section title revised and additional detail added to No Change made per guidance in NUREG-1886. No impact on None. Not address normal form shipments of large quantity.

the package integrity or transport compliance, applicable.

2.10 Details regarding special form capsule and source model No Change added for completeness, no impact on the package None. Not assembly added to address recommendation from integrity or transport compliance, applicable.

NUREG-1886 Section 2.10 for Canada.

2.12 Added Appendices for special form certificates for the No Change added for completeness. No impact on the package None. Not Model 875 Style and Model X540/1 source capsules to integrity or transport compliance, applicable.

address recommendation from NUREG-1886 for Canada.

3.1 Added SI units for radionuclide activities and clarified No Change added for completeness, no impact on the package None. Not thermal evaluations based on decay energy of Se-75 integrity or transport compliance.

applicable.

3.1.4 Added detail regarding pressure compliance for the No Change added for completeness. No impact on the package None. Not source capsule.

integrity or transport compliance, applicable.

3.4.1.1 Minor corrections made to coefficients in several printed No Clarification and consistency. No impact on the package None. Not formulas. These changes were typographical corrections, integrity or transport compliance, applicable.

as evidenced by no change in the recalculated final heat input value.

3.5.2 Details previously contained in section 2.7.4 of Rev 6 of No Clarification and consistency. No impact on the package None. Not the SAR were relocated to this section.

integrity or transport compliance.

applicable.

3.5.5 Added section per NUREG-1886 with notation that this No Change added for completeness and from guidance in None. Not section is Not Applicable to this package design.

NUREG-1886. No impact on the package integrity or applicable.

transport compliance.

4.1 Added more detail on source containment.

No Clarification and consistency. No impact on the package None. Not integrity or transport compliance, applicable.

4.1.1 Added section per NUREG-1886 with notation that this No Change added for completeness and from guidance in None. Not section is Not Applicable to this package design.

NUREG-1886. No impact on the package integrity or applicable.

transport compliance.

Revision Description for the Model 650L SAR from Revision 6 to Revision 7 April 2010 Page 4 of 4 Section Description Change Impact Action Taken By Reference Reported QSA Regarding Pursuant Affected Units to 71.95 5.1.2 Tables in section revised to NUREG-l1886 recommended No Change added for completeness and from guidance in None. Not format.

NUREG-1886. No impact on the package integrity or applicable.

transport compliance.

5.4.1 Detail added regarding test unit profiles.

No Clarification and consistency. No impact on the package None. Not integrity or transport compliance, applicable.

7.1.1.1 Detail added to Authorized Package Contents section No Change added for completeness, no impact on the package None. Not integrity or transport compliance.

applicable.

7.1.1.2.c Inspection criteria for container hardware revised.

No Change added-for completeness and from discussions with None. Not NRC licensing staff. No impact on the package integrity or applicable.

transport compliance.

7.1.2.3.e Step added to describe attachment of 650L lid to package No No previously included in SAR. Added for accuracy and None. Not body.

completeness regarding package preparation for transport.

applicable.

7.4.2 Reference to Emergency Response Guidebook updated No Change added for completeness, no impact on the package None. Not.

from 2000 to 2008.

integrity or transport compliance, applicable.

8.1.6 Description of original shield evaluations expanded for No Changes made for completeness and in response to None. Not consistency with other QSA Global, Inc. Type B SAR discussions with NRC licensing staff on similar package applicable.

descriptions.

approval reviews. No impact on the package integrity or transport compliance.

8.1.8 Added swage connection check under miscellaneous test No Change added for completeness, no impact on the package None. Not section for source capsule to source handling wire.

integrity or transport compliance.

applicable.

8.2.5 Section revised to reference inspections and tests for No Change added for completeness, no impact on the package None. Not secondary users of the package in accordance with integrity or transport compliance.

applicable.

Section 7.

9 Previous Section 9 (regarding IAEA TS-R-I 1996 No No inipact on the package integrity or transport compliance.

None. Not requirements) is deleted as no longer required based on applicable.

SAR revisions. This section now includes information related to Quality Assurance in accordance with the guidance provided in NUREG 1886.

Summary Table of Changes to Drawings R65006 Rev H to Rev J Change Summary Change Change Impact of Change on Units Previously or Currently Action Taken By QSA Location Reported in Use under the Certificate Regarding Affected Pursuant Units to 71.95 R65006 Added comment to see Sheet 5 for additional No None.

None. Not applicable.

Sheet I drawing notes. Specific notes on Sheet 5 This change has no and their impacts will be discussed impact onunits in use.

individually in this table.

R65006 Weld specifications added for the container No No change to package construction or design. Detail None. Not applicable.

Sheet I as follows:

added for completeness and clarity only as the welding These changes have no Shipping Cover minimum welds for on this container had not previously been specified on impact on units in use as assembly specified. Minimum welding the descriptive drawings.

they only document is the same as the welding that was current (and as tested) present on the test units.

unit construction.

Inner and Outer shell welding.

R65006.

Depiction of source check gage added to the No No change to package construction or design. Detail None. Not applicable.

Sheet 1 drawing.

added for completeness and clarity only.

R65006 Material specification for the shipping cover No No change to package construction or design. Detail None. Not applicable.

Sheet I clarified as "mild" steel. Reference for the added for completeness and clarity only.

weldment to Notes 2 and 6 on sheet 5 added.

R65006 Depleted uranium weights shown on prior No No change to package construction or design. Detail None. Not applicable.

Sheet I "label" removed. This information is changed for accuracy and clarity only.

accurately reflected separately on this sheet and the previous label specification shown on Rev H of the drawing understated the maximum depleted uranium weight.

Page 1 of 4

Summary Table of Changes to Drawings R65006 Rev H to Rev J Change Summary Change Change Impact of Change on Units Previously or Currently Action Taken By QSA Location Reported in Use under the Certificate Regarding Affected Pursuant Units to 71.95 R65006 Reference for the top and bottom plates to No No change to package construction or.design. Detail None. Not applicable.

Sheet 1 Note 1 on sheet 5 added.

added for completeness and clarity only.

R65006 Reference for the inner and outer shells to No No change to package construction or design. Detail None. Not applicable.

Sheet 1 Notes 2 and 7 on sheet 5 added.

added for completeness and clarity only.

R65006 Corrected reference call out from "Section No No change to package construction or design. Change None. Not applicable.

Sheet 1 B-B' to "Section A-A".

made to correct a reference error on the drawing.

R65006 Deleted material specifications for shipping No No change to package construction or design. Detail None. Not applicable.

Sheet 2 cover. Material for the cover is specified on added for completeness and clarity only.

sheet I R65006 Added reference to use of optional steel Yes No change to package construction or design. The use of None. Not applicable.

Sheet 2 washer used with the shipping cover bolts.

a washer is reflective of some containers currently in This change has no Also noted that the washer could be transport. Packages incorporating the washer on the adverse impact on units in permanently attached.

shipping cover bolts will perform as well if not better use.

during normal and hypothetical transport conditions as units without the washer present.

R65006 For the 5/16 x 8 in long through bolts, added No No change to package construction or design. Detail None. Not applicable.

Sheet 2 reference to use of lockwasher and thread added for completeness and clarity as the lockwasher and These changes have no lubricant as well as note 3 on sheet 5.

thread lubricant use this container had not previously impact on units in use as been specified on the descriptive drawings.

they only document current (and as tested) unit construction.

Page 2 of 4

Summary Table of Changes to Drawings R65006 Rev H to Rev J Change Summary Change Change Impact of Change on Units Previously or Currently Action Taken By QSA Location Reported in Use under the Certificate Regarding Affected Pursuant Units to 71.95 R65006 Optional tack welding of the bottom plate No No change to package construction or design. Detail None. Not applicable.

Sheet 2 weld nut added to drawing along with a table added for completeness and clarity only as the optional These changes have no of the. weld nut material strength properties welding and material properties important to safety for impact on units in use as important to the component performance.

the weld nut had not previously been specified on the, they only document unit descriptive drawings.

construction, R65006 Added reference to optional steel shield No No change to package construction or design. Detail None. Not applicable.

Sheet 2 support below the depleted uranium shield.

added for completeness and clarity only as the optional This change has no steel shield support had not previously been specified on adverse impact on units in the descriptive drawings.

use as its addition only documents unit construction.

R65006 Added table of the lock screw material No No change to package construction or design. Detail None. Not applicable.

Sheet 3 strength properties important to the added for completeness and clarity only.

component performance.

R65006 Clarified that the optional shims between the No No change to package construction or design. Detail None. Not applicable.

sheet 3 top plate and lock housing are made of brass.

added for completeness and clarity only.

R65006 Added reference to the use of thread No No change to package construction or design. Detail None. Not applicable.

Sheet 3 lubricate for the lock screws.

added for completeness and clarity only.

R65006 Added reference to note 4 on sheet 5 for the No No change to package construction or design. Detail None. Not applicable.

Sheet 3 stainless steel lock housing, lock slide and added for completeness and clarity only.

quick connect fittings. These items are important to the safety and integrity of the source containment.

Page 3 of 4

Summary Table of ChanGes to DrawinGs R65006 Rev H to Rev J Change Summary Change Change Impact of Change on Units Previously or Currently Action Taken By QSA Location Reported in Use under the Certificate Regarding Affected Pursuant Units to 71.95 R65006 Clarified that the shipping caps are made of No No change to package construction or design. Detail None. Not applicable.

Sheet 3 brass.

added for completeness and clarity only.

R65006 Sheet added to drawing to specify additional No No change to package construction or design. Detail None. Not applicable.

Sheet5 material specifications of the package added for completeness and clarity only.

components and construction including:

Top and bottom plates 5/16 x 8 inch long through bolts 304SS components important to safety as of I Nov 2010 Shipping cover steel asof 1 Nov 2010 Inner and Outer shell steel as of 1 Nov 2010 Welding and inspection specifications as of 1 Nov 2010 Page 4 of 4