QSA Global, Inc. - Updated Submittal of Drawings to Clarify the Applicability of Aws D17.2/D17.2M - Redacted
ML20083F698
Person / Time
Site: 07109269
Issue date: 07/08/2015
From: Podolak L
QSA Global
To: Huda Akhavannik
Office of Nuclear Material Safety and Safeguards
NGSantos NMSS/DFM/STL 415.6999
References
Download: ML20083F698 (7)


Text

QSAi GLBA.1?Jf QSA Global, Inc.

30 North Avenue Burlington, MA 01803 Telephone: (781) 272-2000 Toll Free: (800) 815-1383 Facsimile: (781) 359-9191 08 July 2015 Ms. Huda Akhavannik Project Manager Mailstop: TWFN-4-B34 Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission 11555 Rockville Pike Rockville, MID 20852 RE:

USA/9269/B(U)-96 DOCKET:

71-9269

Dear Ms. Akhavannik:

The following is provided in response to the conference call between QSA Global, Inc. and your office on 23 June 2015. In that call, it was agreed that QSA would send in revised drawings to clarify the applicability of AWS D17.2/D17.2M as it relates to welds referenced on the Model 650L package. Enclosed is revision N to drawing R65006 which makes this clarification. In addition, we have made some other minor changes to the drawing for clarity at this time. None of these changes is reportable under 10 CFTR 71.95. All changes to drawing R65006 from Revision M to Revision N are described in the following table:

Location Summary Change Change Impact Sheet 1 Weld call out for outer sleeve removed and No impact. Change administrative in nature.

note added referencing Sheet 5 for weld details.

Sheet 2 Notation for weld nut spot weld clarified to Change made for clarity and to avoid any confusion on indicate weld is a "resistance" weld.

applicability of AWS D17.2/17.2M for these welds.

Sheet 2 Removed material reference for inner shell.

The material specification for the inner shell is shown on sheet 1. Removal of material reference on sheet 2 is to avoid redundancy.

Sheet 3 Added alternate material specification for the This optional, alternate material specification is as good or lock screws (in addition to the material better than the material strength criteria listed in the Lock strength table) applicable to screws installed Screw Table on this sheet. Allowing this specification as after July 2015. Alternate specification an alternative to the current specification for screws after allows screws that meet the July 2015 poses no adverse impact on the component chemical/mechanical properties of ASTM performance or package integrity.

F879 Austenitic Alloy Group 1, CW or CW1.

Sheet 5 Revised Note 2 to clarify applicable sections Resistance welding on the 650L package only affects and exceptions to AWS D17.2/D17.2M for Class C welds whose failure will be insufficient to cause resistance welding.

the package to fail to meet the regulations. The revision identifies the applicable requirements from the standard.

Sheet 5 Added weld detail (primary and alternate Change in location for primary specification (originally construction) for the outer sleeve weldment.

shown on sheet 1). Addition of the alternate construction is equivalent, or stronger than, the primary construction and will have no adverse impact on the package integrity.

MHY3D

Page 2 We trust this response addresses the concerns raised during our earlier conferenced call. Should you have any additional questions or wish to discuss this response after receipt please feel free to contact me.

Sincerely, Lori Podolak Manager, Regulatory Affairs/Quality Assurance Ph: (781) 505-8241 Fax: (781) 359-9191 Email: Lori.Podolak@qsa-global.com

Enclosure:

Drawing R65006 Revision N cc:

ATTN: Document Control Desk Spent Fuel Project Office Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission 11555 Rockville Pike One White Flint Rockville, MD 20852 Engineering Approval RA/QA Approval

-73*LL 2-*o L Date 77,7"64 201Y" Date

SEE SHEET 5 DETAIL-AS 'A INNER SHELL (1),

.13 THICK

-CARBON STEEL OR STAINLESS STEEL SEE NOTES 2 AND 7 POLYURETHANE FOAM, 8 POUNDS PER CUBIC FOOT MIN.

OUTER SLEEVE (1).

.05 THICK CARBON STEEL OR STAINLESS STEEL

\\

SEE NOTES 2 AND 7 SECTION A-A OPTIONAL -

EXTERNAL SURFACE (SEE SHEET 2)

PAINTED AND/OR ZINC & YELLOW CHROMATE PLATED.

SC (SEE SHEET 3)1 SHIPPING COVER (1).

-I 1.13 THK. MILD STEEL WELDMENT C

>-OPTIONAL -

EXTERNAL SURFACE PAINTED (SEE SHEET 3)

SEE NOTES 2 AND 6

-- rg---

I

=1 I.

n 6X AT TOP &

6X AT BOTrOM MAXIMUM 2X

+ -

PER SIDE SEE NOTE 2

- ff~

1 3:*1 II II 0

DANGER 0

=650L 60*02 RADIOACTIVE MATERIAL TYPE B(U) PACKAGE UN2916 USA/9269/B(U)-96 TYPE B C.,LU1O RA*In 'IW SHM&..NO D"1E UPRMM lb Kg 1iAL GWW lb Kg o Imm 0uaa Ai ril

-,_,_TOP PLATE (1),

.13 THICK STAINLESS STEEL.

SEE NOTE 1.

LABEL (1),

LOCATION AND SIZE APPROXIMATELY AS SHOWN STAINLESS STEEL ATTACHED WITH RIVETS (4)

STAINLESS STEEL t*

I J

i I I Ii I liii I II I

I 1111 II I

I 1111 I II

~

II I

I I

IfjI

\\II

  • 1 I~ I III I

I II

'L..

Jill I

III I 4 ~I I REF. DU SHIELD REF. SPECIAL FORM SOURCE CAPSULE r,

1/16 GAP BETWEEN OUTER SLEEVE & PLATES V

A

___rJ--------------

=1 BOTTOM PLATE (1),

.13 THICK STAINLESS STEEL.

SEE NOTE 1.

B (SEE SHEET 2)

TOTAL WEIGHT = 90 LBS. MAXIMUM DEPLETED URANIUM SHIELD WEIGHT = 44 LBS. MAXIMUM SUPPLEMENTAL LEAD WEIGHT = 10 LBS. MAXIMUM.

SEE SHEET 5 FOR ADDITIONAL NOTES.

I-40 NORTH AVE, BURLINGTON, MA 01803 DESCRIPTIVE DRAWING DIMENSIONS IN INCHES TOLERANCES:

FRACTIONS

1/16

.X -b 0.1

.XX " 0.01

.XXX :h 0.005 SEE ERF 3297 z

w-tL5 N

--? Oas-z I g-DESCRIPTION I APPROVALS DATE LTR REVISIONS TITLE 650L SOURCE CHANGER SIZE DWG. NO.

R65006 REV A

R65IT6 N

SCALE: NONE I SHEET 1 OF 5

SHIPPING COVER BOLTS (4),

0.38 X.88 LONG, STRAIN HARDENED STAINLESS STEEL

MAY ALSO BE INCLUDED WITH PERMANENT A17ACHMENT OPTIONAL.

COVER NUT (4),

  • 430 STAINLESS STEEL,

.38 MINIMUM THREAD ENGAGEMENT SHIPPING COVER BOLT ATTACHMENT LOCK ASSEMBLY,

'SEE SHEET 3 U-SHAPED SOURCE TUBE TITANIUM

.47 OUTER DIAMETER

-.38 INNER DIAMETER WITH REINFORCEMENT SLEEVE (2)

TITANIUM

'ý-

TOP PLATE SOURCE WIRE ASSEMBLY SECURED TO CONTAINER WITH LOCK ASSEMBLY.

CONTAINMENT VESSEL,

-SPECIAL FORM CAPSULE PART OF SOURCE WIRE ASSEMBLY

-OUTER SLEEVE COPPER SHIM BETWEEN STEEL AND DU SHIELD; LEAD SHIM AND

-OPTIONAL STEEL SHIELD SUPPORT (NOT SHOWN) MAY ALSO BE INCLUDED.

,-BOTTOM PLATE

-TOP PLATE THROUGH BOLT (4)

-0 5/16 X 8 LONG STAINLESS STEEL PER NOTE 3 WITH STAINLESS STEEL LOCKWASHER AND THREAD LUBRICANT TORQUED TO 135"5 IN LBS.

WELD NUT 3X RESISTANCE SPOT WELD r II WELD NUT (4),

STAINLESS STEEL, SEE NOTE 8

.31 MINIMUM THREAD ENGAGEMENT BOTTOM PLATE THROUGH BOLT ATTACHMENT MATERIAL LEGEND S= POLYURETHANE FOAM.

= STAINLESS STEEL. SEE NOTE 1.

= LEAD OR TUNGSTEN.

DU SHIELD (HALF SECTION), 44 LBS. MAX.

DIMENSIONS IN INCHES TOLERANCES:

FRACTIONS :1: 1/16

.X

0. 1

.XX " 0.01

.XXX d 0.005 I

I OSA GLOBAL SIZE DWG. NO.

A R65006 REV N

40 NORTH AVE, BURUNGTON, MA 01803 I SCALE: NONE I SHEET 2 OF 5

LOCK SCREW MATERIAL STRENGTH TABLE (AS OF 1-NOV-2010)

PROPERTY VALUE LOCK SCREW (8),

.25 X 1.5 TO 2.0 LONG, ULTIMATE TENSILE STRENGTH 70,000 PSI MIN STAINLESS STEEL, 0.2. OFFSET YIELD STRENGTH 45,000 PSI MIN TAMPERPROOF HEAD ELONGATION IN 2 INCHES 30% MIN TORQUED TO 704-5 IN-LBS WITH THREAD LUBRICANT SSAFETY WIRED IN PAIRS.

C HOUsNG E SHEET C 7/8 WITHOUT SHIMS NOTE: DUE TO ASSEMBLY VARIATION 7

W ADDITIONAL BRASS SHIMS BETWEEN THE I

LOCK AND TOP PLATE MAY BE REQUIRED.

TOP PLATE SHIM STACK TO BE 1/2 THICK MAXIMUM.

SHIMS NOT SHOWN.

NT(8).

PPING CAP (1) r

.25 MINIMUM ASS OR 300 SERIES STAINLESS STEEL THREAD ENGAGEMENT, r4 SPRING (1) & PLUNGER (1)

STAINLESS STEEL SECTION C-C GENERAL LOCK ARRANGEMENT (FROM SHEET 1)

QUANTITIES SHOWN ON THIS SHEET AS (x) ARE PER EACH LOCK ASSEMBLY.

LOCK SCREW ATTACHMENT ALTERNATE TO STRENGTH TABLE: LOCK SCREWS INSTALLED AFTER JULY 2015 COMPLY WITH A

CHEMICAL AND MECHANICAL PROPERTY REQUIREMENTS OF ASTM F879 AUSTENITIC ALLOY GROUP 1 CW OR CW1.

Q~)

SECTION D-D KEY SLOT (UPPER AND LOWER)

SOURCE WIRE DA GUIDE SPRING I ~

U P E R K1 LOCK ASSEMBLY SHOWN CLOSED SOURCE WIRE STOP BALL LOCKED BELOW LOWER KEY SLOT

. 11~

~

SOURCE WIRE STOP BALL (PAR OF LOCK ASSEMBLY SHOWN SLOT UPPER SLIDE HALF)

CLOSED LOCK ASSEMBLY SHOWN OPEN SOURCE WIRE STOP BALL LOCKED BELOW UPPER KEY SLOT DIMENSIONS IN INCHES TOLERANCES:

FRACTIONS +/- 1/16 X

0.1

.XX :- 0.01

.XXX

- 0.005 SIZE DWG. NO.

REV A

A R65006 N

40 NORTH AVE, BURLINGTON, MA 01803 SCALE: NONE I SHEET 3 OF 5

SLOT SLOT BALL WIRE BALL WIRE LOCKED POSITION OPENED POSITION WIRES WITH THE STOP BALL BELOW THE LOCKSLIDE.

LOCKED POSITION OPENED POSITION WIRES WITH THE STOP BALL WITHIN THE LOCKSLIDE.

SECTION E-E (FROM SHEET 3)

BRASS GUIDE AND QUICK CONNECT FITTING NOT SHOWN FOR CLARITY.

DIMENSIONS IN INCHES ZE DWG. NO.

REV TOLERANCES:

FRACTONS.x -

/16 A

R65006 N

.XX

-0.01

.XXX +/-0.005 40 NORTH AVE, BURLINGTON, MA 01803 SCALE: NONE ISHEET 4 OF 5

NOTES:

1. TOP PLATE AND BOTTOM PLATE ARE SAE 30304 PER AMS5513 OR TYPE 304/304L STAINLESS STEEL.
2. AS OF 01-NOV-2010 ALL WELDING AND INSPECTION FOR COMPONENTS PURCHASED AND ASSEMBLED ON OR AFTER 01-NOV-2010 IS PER ONE OR MORE OF THE FOLLOWING REQUIREMENTS:

AWS D1.1 STRUCTURAL WELDING CODE -

STEEL AWS D1.3 STRUCTURAL WELDING CODE -

SHEET METAL AWS D1.6 STRUCTURAL WELDING CODE -

STAINLESS STEEL AWS D9.1 SHEET METAL WELDING CODE.

A AWS D17.2/D17.2M RESISTANCE WELDING FOR AEROSPACE APPLICATIONS, CLASS C WELDS, STANDARD SECTIONS 4.3, 4.4 & 4.6 DO NOT APPLY.

INSPECTED BY WELD INSPECTORS QUALIFIED TO ASNT SNT-TC-1A

3. AS OF 18-JAN-201 1, THROUGH BOLT REPLACEMENTS SHALL BE EITHER TYPE 304 STAINLESS STEEL AND/OR MEET THE REQUIREMENTS OF ASTM F593 GROUP 1, CONDITION A.
4. AS OF 01-NOV-2010 LOCK REPLACEMENT COMPONENTS WHERE INDICATED SHALL BE FABRICATED FROM 304 STAINLESS STEEL PER ASTM A276 CONDITION A, HOT OR COLD FINISHED.
5. DELETED.
6. SHIPPING COVERS FABRICATED AFTER 01-NOV-2010 SHALL MEET THE REQUIREMENTS OF ASTM A1011, HOT ROLLED STEEL, CS TYPE A, B, C OR D.
7. INNER SHELLS AND OUTER SLEEVES FABRICATED AFTER 01-NOV-2010 SHALL MEET THE REQUIREMENTS OF ASTM Al 008, COLD ROLLED STEEL, CS TYPE A, B OR C. OR ASTM A666, STAINLESS STEEL.
8. WELD NUT MATERIAL SHALL BE ANY AUSTENITIC GRADE STAINLESS STEEL LISTED IN ASTM A493.

CERTIFICATION, EXCEPT

.5 MIN F\\SEE NOTE 2 DETAIL -

A5 (FROM SHEET 1 A

BACKING SHEET.05 THK SAME MATERIAL AS OUTER SLEEVE

-. 5 MIN RS 0/4\\SEE NOTE 2

.5MI]RSW

.5 MI

((*13/4-SEE NOTE2 OUTER SLEEVE ALTERNATE WELD JOINT OUTER SLEEVE WELD JOINT DIMENSIONS IN INCHES TOLERANCES:

FRACTIONS +/- 1/16

.X - 0.1

.XX 1 0.01

.xxx

" 0.005 40 NORTH AVE, BURLINGTON, MA 01803 SE DWG. NC A

I R65006 REV N

SCALE: NONE I SHEET 5 OF 5