Second Supplemental Deficiency Rept Re Bonnet Studs Improperly Torqued on DHR Valves.Initially Reported on 811222.Completion Not Expected Until 840915 Due to Missing Bonnet Studs.Also Reportable Per Part 21
ML20080J052
Person / Time
Site: Bellefonte  
Issue date: 02/01/1984
From: Mills L
TENNESSEE VALLEY AUTHORITY
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
REF-PT21-84 NUDOCS 8402140432
Download: ML20080J052 (1)


Text

TENNESSEE VALLEY AUTHORITY CH ATTANOOGA. TENNESSEE 374ol 400 Chestnut Street Tower II February 1, 1984 BLRD-50-438/82-04 BLRD-50-439/82-01 U.S. Nuclear Regulatory Commission Region II Attn:

Mr. James P. O'Reilly, Regional Administrator 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30303

Dear Mr. O'Reilly:

BELLEFONTE NUCLEAR PLANT UNITS 1 AND 2 - BONNET STUDS IMPROPERLY TORQUED ON DECAY HEAT REMOVAL VALVES - BLRD-50-438/82-04, BLRD-50-439/82 SECOND SUPPLEMENTAL REPORT The subject deficiency was initially reported to NRC-0IE Inspector R. V. Crlenjak on December 22, 1981 in accordance with 10 CFR 50.55(e) as NCR 1686. This was followed by our interim reports dated January 20, April 15, June 28, August 24, and November 1,1982 and January 10, 1983, our final report dated April 13, 1983 and our first supplemental report dated December 22, 1983 Below is our second supplemental report. We consider 10 CFR Part 21 applicable to this deficiency.

As discussed with NRC-0IE Inspector D. M. Verrelli en January 16,1984, the date of January 16, 1984 for. completion of corrective actions indicated in our final report on this matter was not met. Several bonnet studs were missing when the craftsmen went to retorque the nuts necessitating procurement of replacement studs. The corrective action on this matter will be completed by September 15, 1984.

If you have any questior.s concerning this matter, please get in touch with R. H. Shell at FTS 858-2688.

Very truly yours, TENNESSEE VALLEY AUTHORITY L. M. Mills, nager Nuclear Licensing cc:

Mr. Richard C. DeYoung, Director Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington, D.C.

20555' j

Records Center Institute of Nuclear Power Operations v

1.100 Circle 75 Parkway, Suite 1500

. Atlanta, Georgia 30339 8402140432 e40201

~

PDR ADOCK 05000438 oppICIAL COPY-8 PDR c427 d