Proposed Tech Spec Changes Increasing Spent Fuel Pool Storage Capacity
ML20080E937
Person / Time
Site: Oyster Creek
Issue date: 09/02/1983
From:
GENERAL PUBLIC UTILITIES CORP.
To:
Shared Package
ML20080E931 List:
References
NUDOCS 8309140147
Download: ML20080E937 (2)


Text

]*

2 5.3-1 5.3 AINILIARY EQUIPMENT 5.3.1 Fuel Storage.

A.

Normal storage for unitradiated fuel aaaamblies is in criticany-safe new fuel storage racks in the reactor building storage vault; otherwise, fuel shall be stored in arrays which have a'Keff less than 0.95 under optimum conditions of moderation or in NRC-approved shipping containers.

B.

% e spent fuel shall be stored in the spent fuel storage facility which shall be designed to maintain fuel in a geometry providing a Koo less than or equal to 0.95.

i C.

The fuel to be stored in spent fuel storage facility shall not exceed a maximum average planar enrictsnent of 3.01 w/o U-235.

D.

Loads greater than the. weight of one fuel assembly shan not be moved over stored irradiated fuel in the spent fuel storage

(

facility.

E.

The 30 ton spent fuel shipping cask shall not be lifted more than

6. inches above the top plate of the' cask drop protection-system.

[

L -

Vertical limit. switches shan be operable to assure the 6 inch vertical limit is met when the cask is above the top plate.

F.

%e' tengerature of the water in the spent fuel storage pool, measured at or near the surface, shall not exceed 1254.

I G..

Prior to Cycle 11 operation,10.5 inches of insulation with a thermal conductivity of k=0.02 BrD/FtHr-T shall be instaned at the bottom surface of the spent fuel pool. slab.

~

H.

S e maximum amount of spent fuel assemblies stored in the spent fuel storage pool shall be 2600.

I'

= BASIS he specification of Koo less than or equal to 0.95 in the spent fuel

~

storage facility assures an angle margin from criticality. Criticality analysis was performed on the poison racks to insure that a Koo of 0.95 would not be exceeded. 1he basis for this analysis asstaned an average planar lattice enrichment of 3.01 w/o U-235 and includes manufacturing tolerances.

We effects of a dropped fuel bundle onto stored fuel in the spent fuel storage facility has been analyzed. %is analysis shows that the fuel bundle l

drop would not cause doses resulting from rtptured fuel pins that exceed 10 l

CFR 100 limits (1,2,3) and that dropped waste cans will not damage the pool 9

L-liner.

83o9140147'330902 DRADOCK05000g i

t

L _.,. _ - _ _ -

5.3-2 2 e elevation limitation of.the spent fuel shipping cask to no more than 6 inches above the top plate of the cask drop protection system prevents loss of the pool integrity resulting from postulated drop accidents. An analysis of the effects of a 100 ton cask drop from 6 inches has been done (4) which showed that the pool structure is capable of sustaining the loads.

inposed during such a drop. Limit switches on the crane restrict the elevation of the cask to less than or equal to 6 inches when it is above the top plate.

Detailed structural analysis of the spent fuel pool was performed'using loads resulting from the dead weight of the structural elements, the building loads, hydrostatic loads from the pool water, the weight of fuel and racks stored in the pool, seismic loads, loads due to thermal gradients in the pool floor and walls, and dynamic load from the cask drop accident. %ermal gradients result in two loading conditions; normal operating and the accident conditions with the loss of spent fuel pool cooling. For the normal condition, the containment air temperature was assumed to vary between 65'F and 110*F while the pool water temperature varied between 85'F and 125'F. The most severe loading from the normal operating thermal gradient results with contairrae.nt air tenperature at 65*F and the water testperature at 125'F. Air temperature measurements made during all phases of plant operation in the shutdown heat exchanger room, which is directly beneath part of the spent fuel pool floor slab, show that 65'F is the appropriate minimum air tenperature.

We-spent fuel pool water tenperature will alarm in the control room before the water temperature reaches 120*F. In order to ensure the section capacity of the fuel pool floor, the thermal gradient across the slab should not exceed 21*F (6). We installation of insulation at the bottom surface of the spent fuel pool will help control the thermal gradient across the pool floor and will ensure the integrity of the slab 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> after a loss of fuel pool cooling.

Results of the structural analysis show that the pool structure is structurally adequate for the loadings associated with the normal operation and the condition resulting from the postulated cask drop acci' dent (5). We floor framing was also found to be capable of withstanding the steady state thermal gradient conditions with the pool water tenperature at 150*F without exceeding ACI code requirements. %e walls are also cohle of operation at a steady state condition with the pool water tenperature at 140'F (5).

Since the cooled fuel pool water returns at the bottom of the pool and the heated water is removed from the surface, the average of the surface tecperature and the fuel pool cooling return water is an appropriate estimate of the average bulk temperature, alternately the pool surface temperature could be' conservatively used.

Refererres 1.

Amendment No. 78 to the FIBAR (Section 7)

Stpplement No.1 to Amendment No. 78 to the FDSAR (Question 12) 2.

Supplement No.1 to Amendment No. 78 of the FDSAR (Question 40) 3.

4.

Supplement No.1 to Amendment No. 68 of the FDSAR.

5.

Revision No.1 to Addendum 2 to Supplement No.1 to Amendment No.

78 of the ITSAR (Questions 5 and 10) 6.

FDSAR Amerriment No.79