ML20079R129

From kanterella
Jump to navigation Jump to search
Agenda for 810825 Meeting W/Nrc Caseload Forecast Panel to Conduct Plant Tour.Related Info Encl
ML20079R129
Person / Time
Site: Midland, 05000000
Issue date: 08/24/1981
From:
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To:
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
Shared Package
ML20079E080 List:
References
FOIA-83-579 NUDOCS 8402020079
Download: ML20079R129 (84)


Text

-

.._2_..

MIDIXTD PLANT UNITS 1&2 NRC CASELOAD FORECAST PANEL s

Tuesday, August 25, 1981 8:30 AM Plant Site - Orientation Room AGENDA 1.

ening Remarks G. S. Keeley 2.

Discussion of Tour D. B. Miller 3.

Plant Tour No. 1 Containment Building No. 1 J. T. Walton Containment Building N6. 2 J. T. Walton

_ Turbine Buildings No. 1&2 J. S. Kreple Process Steam Evaporator Building J. S. Kreple Diesel Generator Building J. S. Kreple 4.

Lunch I

5.

Plant Tour No. 2 Yard Area - North G. W. Rowe

~

Auxiliary Building T. A. Spelman/G. W. Rowe.

Service & Circulating Water Bldg.

T. A. Spelman Yard Area - Scuch G. W. 5Lowe 3(C RMW/pp I'g e -

8-24-81 B402020079 831104 PDR FOIA ZACK93-579 PDR

,x gMh S-

//M

--.. ~.

[..

MIDLAND PLANT UNITS l'AND 2 NRC CASE LOAD FORECAST PANEL-Wednesday - August 26, 1981 8:30 AM Midland Service Center

' AGENDA Topic Briefer

' Time Reference *

\\.

Opening Remarks-D Hood 8 :30 ' AM 1

\\.

Introduction and Project 2

G S Keeley 8:35 AM 13 Organization

)*N3.

Construc tion ' Progress over-D B duller 9:00.AM 1

view

\\.

Engineering Status and K D Bailey 9:15 AM 3

4 Forecast Detailed Review

'N

~

5.

Procurement Status R M Collins 9:45 AM 4

Detailed Review 6.

Construction Manpower Review D B Miller 10:00 AM 5, 11 and Construction Mgmt Org 7.

Piping.and Pipe Hangers Design P Corcoran 10:3b AM 6

Status and. Forecast Review 8.

Bulk Commodities Ins tallation R M Wheeler 11:00 AM 7

and Forecast Status Review 9.

Lunch 12:00 Noon 10.1 Schedule Critical Path A R Fbilenkopf 1:00 PM 2, 10 Review 11.

Test Program Status and R E Mc Cue 1:30 PM 8

Foreca s t Re view -

12.

Plant Licensing Schedule T J Sullivan 2:00 PM 9

Status and Forecast Review i

-13.

- Adjourn 2:30 PM

  • Ref erence to Detailed NRC Agenda Item (see D S Hood Memorandum dated 8/4/81) 8/25/81

. m g.

,,---r--s,-re,-

-e-v-

T*-'*'4-~*--

0*-""f

^^"T''""TT

  1. I"#"
  1. ^

.~..

...-=

  • d e

1

-~

SCHEDULED FUEL LOAD f..

t UNIT 2 7/83 UNIT.1

- 12/83

. ORGANIZATIONAL CHANGES PROJECT MANAGEMENT 1

INTEGRATED QA

~

HVAC QC ON SITE e

9

~

TMI 2 CHANGES FORECAST 7 1

l HEARINGS ON SOILS 1

4

1 e

e 9

1 e

6 4

a 1,

I i

.w

,,e-r.

-a-

,,--w-

-,-y-

-,y

, - - -,,,-,pm-y,,---

r,g 7y -,.,,,-wrr,mw.,e.,,w-y.-----ym.,

yw,-e-r,y,,-n-mw,

,-w,y-w-

-e w y, e-y

i T i ll P

jgh"' ~

~

H t-J

' J j!

VICE PRESIDENT

'I MIDLAND PROJECT Jrunes W Cook PROJECT MANAGER ~

Gilbert G Keeley 4

~

I 3

-s 3

t I

MAllAGER DESIGN PRODUCTION ADMINISTRATIVE-MANAGER.

SCllEDULE*LN ETY & LICENSING

. MANAGER MANAGER QUALITY ASSURANCE SITE MANAGER -

COST MAllAGER\\'

inco J Sullivan Ronal* C Bauman Kenneth R Kline Walter R Bird Donald B Miller, Jr Alan R liollenkoj i

i 1

.,/.

O

./

J

^

~-

-.2::: - ~ Tr. ::

_.: " m.

~

I' CONSTRUCTION PROGRESS OVERVIEA r

1.

Current Status of Bulk Quantities July 1980 August 1981

% Complete t Co:::alete a

Large P,ipe 91 94 Large Pipe Hangers 74 82 Small Pipe-58 78 Small Pipe Hangers 11 43 ~

Cable Tray 89 96 Conduit 51 76

.i Wire 5 Cable 28 58 Connections 20 32 2.

Major milestones completed since Caseload Forecast Panel visit of July 1980.

- Completed post tensioning at Containmen,t Building No.1.

- Coupleted erection of the Se:vice Water Cooling Towers.

~

- Completed erection of the Borated Water Storage Tanks.

Cogleted construction of the Secondary Security Building.

Unit No.1 Main Transformer delivered to the site and installed.

l Installed reactor vessel internals in Unit #2.

1 - Complete the installation of over 6 million feet of wire and cable (58% of tho total quantity) i Completed the preservice inspection work on both reactor vessels, and the steam generators..

Cogleted const:uction work on both Turbine - Generators.

- Started a second shift of construction work in the 4th Quarter,1980 Man-ning levels have been 20-25% of first shift levels.

Started construction work for the Technical Support Center.

- Started exterior construction work for the plant Security Building.

Started modification work in the reactor vessel holddown and support area.

9 p o-

~,

on e,' w,%m e

aan

- W e,.

w-.-

n c q,......~. a,;.,...,., i. :. 2 - '.7 7 -

- -. ;, c 7,

-. c L :.

s-g, j.W.,

..e.

. 9

.u...:,.

.;y,..,....,p; y,. y.

o s.,

m..' s

..v

..... :... y,; > n v ~ ;

..u

't.t,

.e n Q.

. ::,. a.y.m. -

,g:v.: w,. 4,.;.g.y g.;.y.q:t.. :. 4,;.m.y:.

ly c,.

. s.

. :~

c

.m :,, w w.c n.<x,.s-

~1

~..

.a"

s.,
  • y;..r

... ;,.;.,,; ;. q-a'

.;.. 3.y -

O g systeC5 s

co5 f '

p itonstegy'alss-c a2s a ye 311sti " a b th-igh ? *c'e' T

ste StST ed 35yggry But yory for thretestgpg 8 pr e

1 idiUS o

t U

eaTW onstTUG for

~

St(,* 3 to be #a coglete-me7 3 ey,

to t

t T$1i e 7 *n%

1 93 er, demiU*zog og ESSS l

be8U

.U 90 2 iS.92% CCN et**13ntsYstemsha9ga t

gt C

So 1 gSSS20sof'**Jinc#"ioil-

""r w.

. et t*lY y 57$d turbine,1 g,

, )99rox.iEStestin%. %e s 3re,gergi giTe ? gt,etto, an foT e

electT*c31 sys voTK-emediS

ction, Current problemsand cc @ l**

ggems-og r e

9

,n 3 (e S. fi" 3

on og coaN g,ticensiUS g install 8 E**

~ p,esolut on og lous leada hSUE*T desi%"

- t-

. "i,

i?"

~

. Besol**

3,311 P I'b.'

q

, cc,tetion

g..

l 1

,..'O I

s-i_.

...qw

-1

.- as., -

l *;_ i,'

v "oM%***

N

.P G

, ) -

g/20/81

,j'.,. f,.ij f, 4

y'. [ j-[

4

.c..?

M.

.~;-;-;? $

.M, 9 4.x

-ll

  • s; q

-(

.f

Q

.+

w i

P

'e4 N'

,g 9

+ jwj l

1 4

I l

l N'

h"'M'89.h,ee,

..,,A

  • --t f'

T c---p r1-w-=1.w'*e-g r

e-T*eerete'+.m+ g9 mi.---m-ifE*-

-'-eW..y*-TV-M.WwW

-'-'-.T rm'1-g'---

T $-ev+19We5-M

-*-'-9-----2**w-v-i'

c, 't 1

L ENGINEERING PERCENT

. COMPLETE

)

JULY,1981 i.

!~

L 1;

1 I

i dl ji e DESIGN 79 %

i

!I i

n

[

e ALL ENGINEERING 67 %

c*z l

9

,,!i i

i 1

I l

{

G157719 I

j (G t S t 2-21) s j

(/

- = + -

o h

n PERCENT COMPLETE BASIS li i

l

[

e ENGINEERING PERCENT COMPLETE

~

h l

. Calculation Based on ALL Engineering Dept l{l Manhours (To Date/ Total) including

{

Contingency e DESIGN PERCENT COMPLETE i

L ll

. Calculation Based on DESIGN Manhours (To O

Date/ Total) Excluding Contingency l

4

)

. Design is Activity in Direct Support of l

[

Development of Drawings and Specs

[

(excluding support activities, e.g., licensing, j

administration, QE, studies, etc)

DSAR 7/0/81 G ISTT 130 I

f!

j i

i

i h

DISCIPLINE DESIGN PERCENT o

COMPLETE i

Design Percent Discipline Complete ij ARCHITECTURAL 98 l

CIVIL / STRUCTURAL 83 L

PLANT DESIGN 86

[

ELECTRICAL 80 h

CONTROL SYSTEMS o

85

[

MECHANICAL 96

[

NUCLEAR SYSTEMS 54 H

SMALL PIPE 68 i

M&QS 89 i

GEOTECH 89 l

CHANGES IN PROCESS l!

TOTAL AS OF 6/19I81 77 i

EST TOTAL AS OF 711 718 1 79 ssinll"f* ' ^"

  • G-1577 131

^

~

__m__...

.i... i.>..i. i.e l..

.s

}

}

i g

i His 3

t.

=

n i..

-a i.ei

.iii!..-

esi itel 6.

4.s

. i

.'i t..

l

,i i.

...it

.. ;i.i.

=

i;; ini,

..i per.l.

,6 siii

.t i,

~~

i,..

6, l.r,,si i

tiet ile

.t.:

i it ith till e!ie (..

Isi.

t

s
i...

..ti

.tii i.ii

~

~

~

lisilial!

66.

Isli

i.I felt sial li.l ;itti. i.

t's e 'I '

l'

  • e i

.i.

e e,1*

i' tit

~

" E

eti, iii.

'.i.

till itsi ints t o l' s!Il site

.l.

., I st, is: lsi.i u..i

~ E

...L.

i g

~~

  • =

ti!i li.i qill siil '}li i:lt Illi:iril siti

'lii ' '..

I I t i

  • s' i*.:j.;

it it

~~

g<

illi tillint int.iniatti llll usi ilo ito op ilt

' i; it i u n.le...

..i

=

~

flei Itti illi !iii illl iliit ill:

lil:

114 l-

'.i

~~

~

if-toi hn lih spl illi uti pi!

ini

,qi s.o p.!

.i n

..,.n n.

~~

tail liit lill lill ilst till lili liii lill it;'

ti'il sesi..

~

it:t ilit 'ltli ;;ill 'ltt! 6lll :lill lies lill * *ilis e li :.4 i

1

..i.] jri..

=

lill t!Il i Il tip

'll I il IIll lill hh init tti: li:.

i l

.,g A ;;

=

~

liti Illi i il U{

il i

il lin liii

!tt:

int tin 'n i..,

it ::

.l:

.I l'

~~

=

llil 'ltil : 1, I l til i

11 6

11 IIII till tili illi (til

'i..

'.si 1

{

es.

i

~~

isti ilinini nii.ilu u tti lisilitil itsi lin list

ni i.

//l..

~

~~

illl itlli' llfil li!!i llli?lsil llIl fill 'It:llilti veil

.I itt i.e.-

i i*, i

.)

i:

O sile lill lltt,liel' i!iivitti. llit' lit 111:416ll Isli;.tel

i-1-
  • g

,6

.l;

-h

~~

tin Illi.I 11 Itll pil i;.6 lill.in lintilil sin u :'

.nl..

t.fr. u i

'n.- {

a=4 litl till i l}

61i1 illi liti l'Il till i!al t il l'ii t i t Ilit 'sitie.*t ties

'j

1. i i,

h

] ]

Illl Illi till II.i ill! itti liit till Illi illi ' lilt-alii istiti 'i n':

i te; e si wc nit Uti up Inl in uit iln Itti till pu nu

.nt m :'t... ni Iff li.

N]

iiii iliti iltillHI niinil iiil _ i e n in.ind iiin; in

, ni.

.ff it..n m

n.r nn un ho inn 6st.nittu.i un n..

st ol n. poi.. // -

.,.q

=

O,C init stp lip nt! the on lingul init Illi t. ii t o,i.n nlu f f.i.

i

j-

"T w

+s, all;llit Illi illi sin,teil ph nu"Illi ini s!iit in

ff
#

.I

=

.,.p ; 1 -l' nog inijnisinil ant t ti liii int oli ni, qu

.nl.... fife i

.p

  • C ze Unopuun un iln nu un hp inn u

h u in# ; 'fi "

ln ooo o.t I

'l

" *C

iltiillifillli Illi I t '.l"lial lill lisliijiii ii li'i f ti / :i'::

i:'aj.' ~ e

'e i.e 'is

.T

-t I

$ 2 ;'i litipini ni ini nunii.

.nl ten uni:.:i f

../.n l u n i o o nii 1

E

=;; O S liit oi t tiilin list

'piititi sin I;il i :l i i fn i i

/ j': :lisi inil-

.i

.qit I

32 iiitaillilin int sp6iina litt lili il f tn.itiif TlH;:

n.

ul_ ;

_nl siiii! 1 o E.

t s'e
  • . 1 %

lill lisiinis ity' iltii.:st, ni:

/l

',fints.

if.o;h::

ni, ZW lin n:r etp ily sii! ion p;.

it;/;.:lillt i fl tinio nio nn u

.:l g ]

=

i.luiti. elli lin si;l till enth fitulitin i t' l i t i!

a :2

'i l-i: Uni I

e

9. 5

..no int uit ion: iiiinne n.n unpoi.

..p...

~

i, on

.i no i i.

i.

a.

l

.c w Hn ini' tui-tili.ilp ini risly:

it u h li!

i 1 lud n n-n i i..

.t.

~

Ina till. llit il!l till sin

!i:.

A foilii'l (l;ot n ni nt ti 1-j_

i ti l

J, "' (4 lll1 lial, illi iiin liti nii spi ut%nni:n p%:>

d.o n

t

.l i-l

~%

till t!lt all 4tifliill

!iin li.i' init! Nt's tri.t N. o i lill lill litt ililiitti illi liti

!li: ' itis A t.

ifl..')

l-i i

i

[

E $)

E int attl jin pil initii:i iiii ni.

-nl:i A -in:. \\ i.

y i i

1-T fp '.;.

T p..3 j

niiiiili nei lip op hin niijin t sp;l.p.p.

6o ll gj;:. e i

~

listillil !)l1 lin,ith itinDnient Heqipili.

t 0

1 o:

J till lil1l lill tilil!tli ll14 Illill:l i

't ilt:86Lia N ii!.

\\

$S"

.. -}il.-lt il d

I titi Ilil li n litthilt lin - n o t tii.tn.gii.6 I; ; N ii.,\\

!![.

.tl i l...

~

l lin ninijit littlun no n;unn.n

.#..n H j i/i n i

.; ]

.h quo i

r noniuipo u n n u.n u 1. i n n i n p.. n 1.3 ( ) i a

i p.n l. n 1 ]

33.;o lihlisp tin p oin tiloni n n nin4 no,,, n 0. : d i'. i \\

1 ]

1-I n..

lillilllll lIl liff ittil5.1.

...it!.i: tie 1: 191 'h.'"

. 1 ;li

' i

.i l

l '-

i 1

T ittilingpli litt

siistut, nittiill.it. fin: af. J...Il i i i

1 l.ii.

tittleililliit stie

ili.iili.Ilitp6n

I.liin

  • . il \\:il. ' ll i

jo.il.itti :. 'I stin:Hitilit ini.n nii II:'i.hi n:.(n :

lid N.A 4'

I os ii:l i I

9 s tii.: n r ut.

t;;

i.u nt!

panni o

ini.

>:l. ; i -... t. M hi.

+i.1:

'l.-

t l

un ni. nn

.iu.;nilan n+no n-

.n

.in il t o

.n"lM.

.. 4 o.

l.'.

T l

9 o

.O.o

- -)

e

.h..

~~

~

.no.n

.in in n on in., Hi u..

U

it sii t..l:.i; eli.

i :.il e '. *

'toi-

litili' iestillii
tie?il it-

g

i!stui,'!.ii' g

i io i..q l

.'t \\ '.I.tp 1

l ilo neenlipott

:!lin, l

w

,iiip on.ro: ::4.p..i!..ii

..;p'u

'.l.

l-

.i

.e!

o'.6

.ii l

4.'

1 W R T ~!

I s

s A

s l

W s

i N3W1*GWAIDC9 I.

l l

MANHOUR CHANGES SINCE ADJ ii FIC 6 1,000 Manhours l,

e SEISMIC STUDIESIREANALYSIS 275 j

e HELBA 200 e ELECTRICAL WORK PROGRAM 115 l:

e RESIDENT ENGINEERING 210 4!

SUPPORT TO CONSTRUCTION e HVAC TASK FORCE 25

. LARGE PIPE SUPPORT TSA 40 t.

t

. CLASS I STRESS GROUP 90 i

SOILSIGEOTECH GROUPS 100 J

e LICENSING SUPPORT 55

!j e STARTUP SUPPORT 40

. FIRE PROTECTION 25 i

e ENVIRONMENTAL QUALIFICATION 25 l

e INSTRUMENT SUPPORT DESIGN 25 H

e QUALITY ENGINEERING 40 l

REQUIREMENTS i

e OTHER MISC CHANGES (approx 135 l

400 changes)

!t e TOTAL CHANGE 1,400 f

a" "?::,'" ~~'

w.

2 a--e t-e+4-*

      • ""C 9

I I

'f k

I l

I n

i in li i

l t

I i

l i

i N.i I l l

I l

18 I

(

o n

nq i i

t.

iw.

4 i

i i

l-i il i

li fl 38 I

l l

I II H I

il li l

- i

{

l i

l i

l l

l

M ho

- i (fn !n l

i h t LJ i n h

'i i

Qj liti in i

n il l ll i

i nT t i

I i Hun i

L iin i

i n-6 of I

i l

.I fill ill i

in :ll l

l ll n

l

'l li t t flil, gi i

11 i

t

'}

Ek; f ll l

l l

C lii:

il I

l l

I i

11 i

i i li #1 l

f, Illi il 1

?"

i n ni i

5,l n

i ni ei i

l l

L o i n na i

un +

n g%

i n ni i

.: q i

I nn

!n n.i a un in un i

l na in in nu a i

i

n i

l h. nit on ini il un un no oj i n in ni o

i n i

till il I

i

.[,11 11 lill i li till lili fili life litt illi ltri lli lill list it I

4(t i. h {.

[

iin fin ilitu a l H

lli i n slet liii in t il l up no is o :n n ani nei ni un i

111) till lil5 t ll ll i.

F l!

lili ill! lill ll 1

lill li!( 11l l illi illi, tilt ll l HH lit ia lill fit liiM.

I 11 li

}

lili liti eitt liti llel lill

'!!! tlI l liti-ilti ei i li, lill 11ll

[

~

illi

til, litthill li I

61 i lisi Ilii liil lill llll 1111 stil ljtt illlllill ei!! Ili ll11 it' l" till

!!n lif fiU n inn li.

i stil ilii llill alit oli illi on fin un nu i;tilnn i

6 i

lill litt tillill oli till llil'itti i n i-flit lill fin 111 uli till ini 1161 all

i. !

t y

no itti ttli d lin Illi

! 11 1: 18 un iln un se!!

ni on liti nn ing

nl F i 2

I it!!

lill

!Ill #3 I

il lin !ali illi lil-ll till I il li t t-lift lain tel till (tij 1

i li

~

uj ini no inn ot i i

n on 6nt in n un

!.n i o in ni un nu oi ii I

t ig w

ill till f.il lii % il i

It lill till fit 11 Ifil lili i

il lit til lijf :In it it I

} i hE llI 11l

=

1 ft lilitt-i Ill llit lill Illil 11 lill lill t-il lll(

Itit lits lltt il it t

I l

l N I~

lill ill i

11 lili \\tli lili till lill Illi

'll till illi sill till till lill titi: lli, 11,1ll<4 92g on n1 on on-O no i n un un on on no un nu nt un onnin on :nn

~

o z nn n6 on on m no i n on ipt on on on on nn n. l on nn on no,un RS o un un n o! n n ut

!ni i n un do un on un on on un on u n-un in ili QU

=

iin oil sin nie ii Allii i n nel nli oil litt ini Int i!st noieni tili l

1 i

i; it 6 Sg.

=

It!I fili Illi Illl

!l!!YlllIllt Illl lill Illi till"ll!!

till Illl liff 11ll IIII l

ll1 fill g -j g uit tin un i-o n nT. t i un nn un ain nii lin lui int irti sin un i, o ni liti -3

,E < g,Lui lin liit !; Y li T o alla itill llo q ui liil iln nll lin

!l he ils ull

,t1 oI j $ 'o 16ll lill lili ij. At 4hi,Isli list illl illi llll 1:1i t

.it l!!!

i t i-

. ti: ills

'q1 i

ti i

5 lill! !!ll lili to liilillilisi lift till Illt illi ilil i

i i

11 n it till litt

!?

I i

t

-c a nil.lill illi tiil liii li

, ti!

nii Itji lill lill IL I

till I

lui lin byy litt nis Hll du illi I

i!!

tlit 1ll1 litt un il I list 1

i ll's illi 11 I

o r; g$2 0

'hh""' 4h hh

'io i

Rn in nn un un un un no un on un i

i 6

o.

on on n i na en mw i.nn on n, inono ni on on oh-no nn on n y

int tili 6

l o l

l 11 ilil M lit lil6 lit liti liti ill lill flil till-tit Ili loi ti 2

nh on i

i n.1 Fu ini M ui ltii ni lit liti ni iln hh nu ni ni 1n it. :

a 4

p ai.aan ias ul llll lill,,QI l{l

ist i t; il l
ll1 fli, glij gl.l lil it.

I ll i.

ij a y

al; I lill lillvilli %

Ill lift lilj il I illt till

,.i l i f

s i' i il il l ll i

1 n

I no n o u n,.n w n on on no on on o no, ni n, u o io r

(

si e

i Illl lill 'lill illi ( N ifli ill) illi illi illi liti till 1111 ljij ll4 4' 411

~

h 1

Itll lift till stil t illki t }llt til; llli till llIl-till fll' lll{

ll 'l 13 "

L:

l qu flo un liii int i.\\ iiin nir on io nll inn l it n

I l ii g d* I till Illi l'il i;ll Illi lifYtl lifilitti l

18 lill illi i i

61 i il 3

(d i ij on un h!!unn un'onWun nu un un int Lo

- il o

ni nii

~

si 2

liti ills iinlists ilii

!!is si, tiili ilti lill lili isle 111:161 i

lil.

Illi tl i : $ +1 8!!).!!I1 illi Illt tl'l till'lis lilli i

11 Ille lill lili till llll Itli llll 3

$ I il ill lui till till lip alli sit bill i !I Itil lill lisi lili llil Illl 11 I

l jj "j[1, nL ill!

illi ii:1 lui till f i n ilp !!

i ll till lilillit n.1 nli ill!

ill l

/J g'

ill anl oli uti stn Illi liff '.1 ;, n i l. fill 1ll 1881 ijti' liti illl lut 11 5: h Illi liti ftit hti lill-lill fin i

Hin 111 t Ili ini liil till Illi till

,, y 3 0 {i litt l{fl till Illi till. Illi i \\'llli lill lit.

till till flil illi ilff f,

y j* jj i un Illi Illi fut ln In fin u, lil 'ini Un iin ille lui illi in!

E,g ad i

ini 16!I 1111.1111 till till Illi tilf i\\' nu iln litt lill 1611 illa lill fI iiL i ilti till lill !!ili till Illi ill!

liil ilN!Ill fill flit lisi Illi tifs lill aI E 7 **

l l till till lill 181' fill ills till till fil! ki llll lill lill liil ille flii g

~

g%:g n..,,

,,,....,,, 1 nit lita lil! #itt lio llit riil In n!!, t 4 iill fili nie int lilt lui i

Iliel.llilit elnilit s elle t til liis ini i:li sili' e sit tit el. lililin:Qie elii t.s. reli tils;ll!!.

t E

H r.

e 1000 L 4133d W3*d l

~ _... _.

,,se...

.=?"/*

..n.

.4.u.e.,e>=+

  • +=+-er

'#~

  • * ' * ~'

g j "*

i I

$ lit i

l}li l-l li I

'I

)

i II l}

l l

Q e

a o on i n i

i n i

i n

i i

3h5 Ill ll l

e I

liij I-l

.' I i

i

! 'l

'l I

~

%54 ln F nii i! list il l

1 i

i i

r I g 3 3. ',

I n nl l '

.41 4

lit!

ll !I I il

't,

. lll i

i 1

1 l ii i

t J

~

a l n-l:1 lill in l'I I

I Uh I

t

!H l' I

ii 1

1 0

F n sii a $

it lin i'l l-1 i

i ll t!

i i

il t

i

(

  • ~s t

llll lli l0 l

l llti llll lll l

l 'l I

i I

i l

l 4' 8 *-

nn ni I

i un un n l io i

i n IHI hi 3

ii lin liti fl.

li 'i 1H 1

l lii!

IIl li l' i

ll niis i lnniin un uti 114 ll t

'til

.li i

is lill ii

liti, nl it i In.

.pi

=

non

-o, un un no o in,,,

n, nn un

,m, um n., m lui

!nl lill 0; 101 foi titi itil ll l

ill l

I 111 illt un n!

till ini h Iun lut -

lill liil Illi j i' l!il ll!l till IIst I

'll li, I ll jil itil llil ll:

litt i'!!

it.

i, (ill ilt*

illli]*.\\

1lil till lief Illi I, ll i li ll r

lill illi

{l lill ll lllli1ll 11ll til (t{l ill"

-l hn n un Mun on on tin nii i h n t uit hi it un uit un no tin lh -

till ill liii i li lill illi fl!!

till lit!

1.fl'Illt Illi 11: l lill till litt litt litt liti lllt*

i un pti illl in do fin lhi ini nil I

il ini un ne' nit attilill sill tin Hi titi- *:

$$tt 11:1 Ilit thi lip Isl}

illi ill}

lil}

l ll till lli

((( it 's lillitil ((lll ltil ((l4 Ilit*

~

iiit it lin tii n A on lial un pH 101 IHi in; un li nn no un lol on i ii in h

no up n otin int tui n 'i in un un lin n!

Ini no un un on i 0 w

til in tin I Ws ilh Yi illt llit !i l

i il till lui illi lin Inil!tuttin lin tol O tt 7,

j till 16:1 llil llibilil %

Ilit illi li!i liii.illi lill Illi lili till'Illi'lli till till tili o

un t

i on un)iii n\\

  1. n nu un on:nn un on nii un on ni

.u,i un un N* $

till i

i Illi illlliliittli t

it'llll til!

Illi it!i ilil liti ilij llit till litj ili titi litt ehG un nh on un an itn ui sin nu nu lip un on fin ho un nu in

- ii un

=

@Mm Ill lill ill}.llit l@

il k gil lill il'i Illi, llii INI slil llll liti Illi Illi l-l

$${

Itt no l'h litillin i ni ll 2 lhi lui !!il ini tilli!!!1 lin ijn ill!

lill tile tail

lti.'lii

<u no io un un inn na nn nu un ninun on un unl ihi un oh on on ogWE lit t i ll stil litt tC

- cil%)ti liti liel st il

'iili itti #lIl flief ill till lill f(ll till

  • g jEde in un in siis iiT

\\ : ni n un un n i un uh on ont o hn t'n I :i un

$ r$ C 5

41 ill-lil till 11.,

I Wi!\\i nil inn

  1. 1 i:llit liti in!

illi lis; lili 1, i' i

{

ini 5 t-l 'It t il in He lin dn A3 liit uit illi llti I! n lih Illi list tilt on i

i Illi g g in ;i iiii in un imp ygun ni; on on no. nii inn tni un in 1,

i n.i g3e nu o n oli sin ein un 4. i Aqni un uninh hil ein on ini un ni siii ni s G

, no un i.\\tg n un on un un oli un un union ni ill Illi lll1 lii Y t! \\\\

lill litt stil lill lill till Illi I ll 11ll Il i

l'

]

j-i hu no isn W i.

nil sin hh ini Itn nl ini i ti ti i 'l i

j i lhi Illi F li t M lii.

il His tili int lin

lis ini til i

i 1

i 6

4

  • j f. Illi III!

l 18 lilllill I !. lll1 t ill 'ill! liti lill l!ll l

l I

(

l $

li Illi lift 1 li i s t i le t i li N iti illi ilii Ilit liti. Illilli ti ll till. tlil g

I 1111' 111:

lill ilti 11 illt

\\ lill! 'llit lill fili Illi till-illi Illi liti 1~

I liti ilil liti Illi s ili f il iit \\ ;ii litt lill lil {ill lifl lill lill lil!

3 3

nn nii i o pH ingi H uinNi un ini ni un un on n pit t

r Illi illi it hii un\\ n un n\\ no ni tu n in un n 1 :n

~

1: i un no no nh nuigti' un H4un no in !!

l i n Hu h i n i

[E y lili liti illf;llil 144811\\l1ll11 l\\i iti:

11:1 illiffiti l

lifilll illi-fi i

l

i -

u n-o n un on on n \\ln.n i,\\ unn!n on un un no un ul!

l

3 33 on.nu uti un
nti olitii inNin Hi ini un uti lin ni ien

(

En ;0 till till Illi litt lili'ilitNel illl \\i.l g li)

Ifi Itll till liit lil till l

~

l 1:

tilt Jfli till allt. lilinlillsiffill! l ii j " ' ' l ife !!al 1111

!!ll il lit 3} if nit lui Illi litt li n itsi Q uill til eel ni!

lill li!:

liii

,ili "I

tj t!il Inillfil foi till lill 1.W n i n il d

U u{ t i$ll ijf liti

!!il ill!

111 Hi'

-ji ).

nie un Ini un

!ni tal il I*A n ' l i l nt iniinn pl!

til ill

}

~

u, nu un on, in' un un nii n i un un u n 'i o o n ini inlin 1 400 H

I tili tot in lhi nei isti il\\ ' l I

lin un I !!

lin ilii i n til l

i, l I ( {

Illi lui lin tui. fin in lin this I

un un in utt nit O n i

o l

h I

till litt lill litt fili ill lill filik!I fili eill

ii 'illi

!lli illt 8

1 l

s o,.o o noon, oen no n,os, on! no-nu m un u n no l

x x x

=

a

= x

a

=

(CCC'1 X) Em!3 6

i

?

I l

~.

.. w -

. -..... ~...

. ~....

~m..

..-m-.

~. -.

.~

-~~- ---

~~

~

- -~

E-6 }t 1 i l

i }l) illi ll

' 'l l

11I lill lll1 llll llll 'l 114 'il j il t Itit ill (lj O

j g

)

}

l1l 6 ll l.

. I l

Ill I

lll1 i

' ll

((

ll ll

-)

, gi 1

il i

(

Illt i

l l

h 5

i R 3 *;

I ll l ll 111 I.

fil4 l

1 I

lit tl

'l

(

iii li l

I f

a i

" t t; {

l' il l

16 i

i

.ll l

1 i

l

. l (

i i

)

1 lll g

g o T_l t 14f f-i l-l:

1 H

i

(

i i

)

i i

i l'

l Ill ll$l ll 1 ll ll gg l

ll{

ll l

il ll' li i

l l

l l_

ci, I

ill {l'l ll 'l 'i'

{

111

),

i I

i 'l ll l

. j i l h

i i

I ll 1 1i il Ii

'll il l.

l l

1 1

ti

),

j il l l l.

I iE I

I il

't i

't i

i l

]j '

I t

i i

i l

ll l' l

l

'Il

(

l I

l

)

11 g

l i ll l

1 i

li l ll l

.ll lI II ll t }} li 1

  • h i

j' g til-Il I lili

lit,

,1?l 11 i ll 61 l: Illi til Hl1 1 l i ll l

(

. Q-jt- 'lli ll i ill 'll Ib lill ll Of I l l l i f illi l l l lil lili 11 'l ll }ll. 14 I- ~ I it i.i I ii i 'll I i-I: ) I ll l il - l ili llt ilii i ll l! ij j i i~ i l 11 li i fit ] li H ll' tf I il 'l I il l l li :l F# H1.lil I l-l I li ) i i = i } I l I i li' lil 11' ll lill ti l; il I i l il l l ( lill i}} 1 I til i

1) Il.

I' ll* ll l i ll l - l l llliO{ll i II ti ll ll '{ j i is i ll ilit }ll1 i '}l ll-l 1,l l l l l 6lll alll* lill I il til till li'ITill llt fl I llil l 'il ll! ) ll lill llpi l} illliliti, llij lill ll'l* till Illi lit-t il li ll i tli lit lill lill 'l l li (l ( lill ll il till }}ll lip' ll l ~ lili l11 ili Ill' lil 'l lYi lit illi'llt i l I iti l <ll l illi lll 1 6ll 1 ) l' I i ll til' illl 'llli llY lil llll lll l i l i ll(li' i l ', L}- i }} l Il 1l 1 }]l_ l' i i I f 11 1 ll11 Illl lji 111% lfi Illi llll ( (' ( ( li :( lil }}' l) i la i Illi ii lil l ll lill lll lli lllikIll ( ll till I i i l il I })1 1) ll l (( j;l illl llll 11 J 1l11 Il lill illi liliillllitil i lt<ltli ill1 t i ll' llit lill li,

ll llit till ill!

I .i i j i l? Il}} lill l ll ll11 '1111 til Illi till'Illi lill lill illl lill l'!I 1i (Ill till l {1}- tl i oy W i l Iiji l} 1) tl II lill llji lhi llil llll lill l II ll} llll lll1 4 ll l l llj llll l l: lj( g ll '!l ll I l'll lill }l11 Il%IllI lill lll l l lil. lll lifl 'l: ll (lit llll ill }ll i s i Q g Il l ll II I lill lili llll 10 kill flit llll l { lill lll lill llil lill li ll ,l(' ill i M llil lili }lll llll Illi IIll I (hY i b gn i Illi ll($ l (( litt '}i illl llJ) l )) ll ').IIl l 'l l }l g % lill litt Illi Illi lfil lill lh. ll:1 illt l'lt lill I it illi till l li ll. ) ill; l' Ill illt g 2 j liil: lll! Illi 1863 11ll Illl l' II M !ill lill l!ll lill llIl ille !!ll ll{ lill Illi l'It 'llij }g y lili lIll !lli lll III lill l ! I I. It d lll lill llll l}l i 111. litt ll 1 lilI ll l l llll g go jl{l lill llll lli -lll ll11 llIl fil:ljl lIll lill ll ll I l 'll i ti i I (lli j' I jlli l l $ga lill ll lil lill till lli ll til! l it till illi 111 ll ) i 11 Ill! l-l till ill ll ' G5Z lIll ll Ill' lill I -{l ill, {ji Illt iLl Illi till li'l ll i li ll illi _!ll lll1 q. ll11 1 lill till 4lli lllt I it,lill Illi llIl t il llll l*ll lili llll lili Illt llll 11ll l lili i 3 lill Illt }}ll lill lill 'I lli Illi lill sit)'lill Illi Illi l l 14. llll (lll jill flit lij llll 4;ll $O llil'!lll llll llll {.I i il l$il ll1 tilf illl Ill) llll llIl lll l lll lill !l' il I till ll h I! llliil 11 I liil l ll l Illi til 18!! Ill illi Illt till il I fili il ll 1. llll ll i l- 'l l i li; ) ll l 111: Il I lill lili Illi ltll llll Illl llll 11 1 I ll ll ilt il { lli il l l

l}})

Il l ll!! llll ll41 It'l lill llll llff'[illlll llli lill lil {' ll l' ill; lill }ll }lll llli lill 11l6 Ilit lillillli llIl illi Illi titill till lill :lili ll li l l.1 til!! (lit til,'llil_ y !l!l Hij lit Illt,lHI illi lill I!Il Illi

l l ill liti liti 1H11 1111 Ill! 11!I till

!!Il uti ~~ till lili ill y {ill till Illi till !! )l 'Il lili till llit lill 11 i leil.lill Illt till ll}l il lill g Illi llll llil till ll ( l {l llll lill lil' illl ll l l II 'lIl llll ll l 1111 il 'il liil tHI thi littliittil illi liti

lli, lilj.

il, I liil ill l' I! l ~ ll11 l Il.ll I j lill 'llll lllt lill),ill k !l lifl llif illl'illl lill IIll llll ll II l lill llit.llii ill! ;l16 lill til!lIlli ll i ll11 ll!l Illifilli Illi Illi lill lll liti "I lill lili Illi lill Illi rdi lill I lli 13l 'lls llli lill i i lill ll I lill ll l lli i illi Il i ' lli 1 .3 Illi lill 1881 Ill! It k illi till llll lli till lill I i .lll ll l lIll Illi illl") jl lll} llIl lill ll 'l lll lllYlltj l lll1 Il Illi lill l. l! Il il Illl Illi lill il e 50 llli lifl llll ll 'l llIl llll Yli l llll ll 1111 lll! lll l IIl l' l ll I ((ll i Il !$ 'l llil Illi illi ll t Illi till @ll i ftll al'l Illi illi' llt 'll ' l, i II. i liil i

1) I$, f lill fili lill, lill. llll 1lll lh lii t llll il i

Illi lillllll _ II lli till lii) }}}) IIII'lllI IIll lill lfll lill l'il Illi liktill 1 41 (1 t llIl lill !!lli llll' Illi " h a il I 'll 's till lill I!It llll lill llll Illi i ll ll$1 lli4lll I ll lill 10ll {lll Illi i ll'Ill! Il 4 il i liti till Itli lill till Illi lill !all lill llllT1lll1tl ilil !ill !ill filt i il illi (lli ll. ! 14$1 till llli.llli lil} Ilil ll!l Illi illl lill dl lii! Il 'l llii filt l{ll (j ll l lill ill! lill Illijllll lill Illl lill 11ll lill lill 'T fill il l lll1 ll!! Ill! Il il (

  • llll' illt. 6tle-tillll'll tillllil!

!!il lill, flis'Illi. !!!l lilhtill illl fill lill! !lli l!!I alli. t 3 (0001 I) spu3 ogqq e' 4 e .==%. wee ~ -ew..- ee

1,. f ii ~ OVERALL PROCUREMENT STATUS o i jj e DELIVERY TO JOBSITE 4 i .I );

  • All Major Pipe Spools (i

j . Appro~x 95% of Valves; Balance Due by 3/82 ,1 l l . Approx 90% of Instrumentation; Balance Due j. by 12/81 mg . Approx 90% of Hangers; Balance Either in [ Fabrication or Due by 12/81 I i l i i (

o. s,,.,2, I

j, POWER AND CONTROL WIRE AND CABLE t ll i(; Oty on Oly Divrd l P.O. Description Order (ft) to Date (ft) Compi , E-21 5,000 AND 8,000 178,355 125,355 70 g POWER CABLE E-22 600 V POWER CABLE 667,000 652,137 V 98 INSTRUMENT AND 1,650,550 1,650,643 100 i E-23 j; l SPECIALTY CABLE l E-26 600 V CONTROL 5,920,000 5,666,946. 96 [- j CABLE E-56 COAXIAL, TRIAXIAL, 38,000 39,984 - 100

I AND TWINAXIAL CABLES L

I; E-59 600 V HIGH-16,000 16,820 100 li TEMPERATURE POWER CABLE j i; E-60 INSTRUMENT AND 3,565,000 3,503,409 98 . SPECIAL PURPOSE CABLE p 'i TOTAL 12,034,905 11,655,294 97 i j ' Balance of wire and cable to be delivered by 2/82 G 1571122 _I

PROCUREMENT TEAM IN SUPPORT OF i SYSTEM TURNOVER L, i r i i e BECHTEL PROJECT PROCUREMENT TEAM REORGANIZED TO SUPPORT SYSTEM i TURNOVER L h e IDENTIFY LONG LEAD ITEMS AND CRITICAL PURCHASES .,il e ATTEND WEEKLY CONSTRUCTION. SYSTEM 3 l' TURNOVER MEETINGS TO ASCERTAIN L PRIORITY PROCUREME'NTS n L e ISSUE BI-WEEKLY REPORT TO MANAGEMENT i h ON CRITICAL PURCHASES h. I i e INITIATE APPROPRIATE ACTIONS TO ATTAIN MATERIALS AND SERVICES TO SUPPORT [ SYSTEM TURNOVER / G 1577-110 l

i
}

PROCUREMENT i INCOMPLETE CRITICAL PURCHASES i O; H i i Number Description Status N E-34 LOCAL CONTROL STATIONS DELIVERY 12/81 i (Gould) D l J-202 TRANSFER SWITCH PANEL DELIVERY 4/82 r p FIRE PROTECTION (Harlo) t J-204 INDICATORS (Foxboro) DELIVERY 11/81 N [ J-207 ECCAS CABINETS (Vitro) DELIVERY 11/81 O, ij J-232A ORIFICE PLATES (Vickery Simms) DELIVERY 9/81 1 J-245 TRANSMITTERS DELIVERY 1/82 l3 (qualification prog (Rosemont) ram under way to (unqualified) l; i IEEE Std 323-1974) i U DELIVERY 5/82 (qualified) I G 1577-119 l

}. _ u PROCUREMENT l~ INCOMPLETE CRITICAL l PURCHASES (cont'd) 1 4 Number Description Status i' i J-275B ESIS ISOLATION CABINETS (Vitro) UNIT 2 DELIVERY l 4182 (unqualified) ,,j UNIT 1 DELIVERY 7/82 (unqualified) l' (qualification program to be QUALIFICATION l' j complete 11/82) COMPLETE 11/82 d J-275B 9 kV ISOLATORS (Vitro) DELIVERY 3/1/82 i r, 'h J-280D PLANT COMPUTER (MODCOMP) HARDWARE (replacement) DELIVERY 11/81 j L SOFTWARE i COMPLETE 1/82 i M-127B TWO-INCH GLOBE VALVES DELIVERY 4/82 I! (Henry Vogt) j' l l, M-132 MOTOR OPERATORS (Henry Pratt DELIVERY 12/81 Valves) i, G 1577124

-u

.

  • sa -.

h

<i u ' I. 4 CRITICAL SUBCONTRACTS TO GO i 't Forecast Number Description Award l A-60 PENETRATION SEALING 11/81 i C-118 WELLS FOR PERMANENT DEWATERING 10/81 i l I C-194 UNDERPINNING FOR SERVICE WATER 11/81 PUMPHOUSE t l C-195 UNDERPINNING AUXILIARY BUILDING (talking '12/81 {l with prospective bidders) lu i l-l i e f 1i ti l1 a, sir.s zo 1 l t i I Ii l l .I 1

i

PROCUREMENT DIFFICULTIES IN TODAY'S I

MARKET 1 i l3 Difficulty Actions Taken . BUSY NUCLEAR GOOD RAPPORT i

j INDUSTRY VENDORS MAINTAINED WITH

~ MAJOR SUPPLIERS I. c l . LONG LEAD TIMES PURCHASE

i..

(sales backlogs) ACCELERATED 9 SCHEDULES H CLOSER ~ L, l COORDINATION WITH SUPPLIERS ONBOARD DRAWING ~ ) APPROVALS AT i VENDOR'S SHOP HEAVY EXPEDITING I j I

o. i s n. i i r s ~

n_.....,..,,.,.. ,v. -r

N PROCUREMENT DIFFICULTIES IN TODAY'S l~

MARKET (cont'd) h Difficulty Actions Taken i. CLASS lE QUALIFI- . MEET WITH VENDORS [ j CATIONS TESTING AND TESTING + [ l (long lead time) FACILITIES t u . IEEE Std 323-1974 DIRECTLY U . IEEE Std 344-1975 . ARRANGE FOR . NUREG-0588 QUALIFICATION o TESTING DIRECTLY OR COORDINATE i g WITH OTHER H UTILITIES I . INSTALL EQUIPMENT E, ll INTO PLANT PENDING COMPLETION OF o 1 i QUALIFICATION I i-TESTING i G-157 7 123 l-i ~ -

3 l f } HIDL rfD PROJECT' VICE PRESIDENT i VICE FRESIDENT P&T ,? 4 l J W Cook R B DeWitt f i PROJECT HANACER 0 $ Keel'er .( This line solid to R8DeWitt for the following:

1) Emergency Planning
2) Personnel Training '(Operator Licensing)

I

3) Cenatal P&T Flanning for Operation SITE HC: OFFICE
4) Simula tor 3'

Site Hanager D E Hiller

=======

Anet Site Hgr/, Plant Supt i

  • C B S' Lade l

i SCHEDULE CONTROL CONSTRUCTION-CONTROLLER PLANT SUPT TEclNICAL ADMINIST RATIVE I SUPERVISOR SUPERINTENDENT PLANT PERSONNEL PUBLIC AFFAIRS = OPER-HAINT SUPERINTENDENT SUPERVISOR DIRECTOR DIRECTOR D D Johnson T C Cooke V Brown 'T W Elward R E McCua. J H Bielinski R F Kinneer N J Saari i j f !? 111:r/pp D 6-80

  • I i

l l' b ^ 4 = s i I } i / l } e l

^ ~ ~ CONSTRUCTION MANPONER REVIEW s 1. Work Force _ Expected 1981-June 1980 July, 1981 1983 Peak Pipefitters (Mechanics ~and Welders) 542 831 880 Electricians 292 594 700 Total Manual Work Force 1,218 2,068 2,200 (All Crafts) a. 'Ihe expected 1981-83 peak for pipefitters is very near the current em-ployment. 'Ihrougli the continued use of Canadian pipewelders, it is not expected that meeting the peak will be a problem. b. The expected 1981-83 peak for electricians is below the earlier.1981 . peak of 712, therefore, no problem is expected. .e Labor contract negotiations for all crafts will occur in the spring of 1982. 2 3. Productivity Construction productivity is maintained by a joint Bechtel/CPCo production engineering team that was formed in late 1980. Reports and recommendations for improvement are made to management. Productivity is also maintained by the use of unit rate comparisons. Midland Project Constnaction produc-tivity is comparable with the national average for nuclear constmetion. 8/20/81

%3 C,

  • :.. i i
  • 3 f

. * 'Y ' " x ll',*.$?.T.,:&.),.*.f..,. *.',;; {.V.bi-N..:!.d.!;.*k. ?. '.?., ,;.?- Wy l] q s & ';;. If T - T'~ [ .b: . Q)'

  • Q N

k y.2}:g% cn. } ts

9;; O en 7

y L JW.,.. 4 0 8. C O. A_ w: x:.: to - 4 .n... < ....,.-.; j.,. a _ c'. ' ',y. %. 4$ 7.<.%,; e '.e".' m .. -e. a.......,. . l . ,7't. l ^ c. Y.T * -W'w.,*lLc}. . Qt;~ f.'[

  • ?qq * *

, E.': t 'W >. ' u .*'.;c'?;- 'f ' ~c%.*'

a.. % '. : L*

,,, u.:;1lL. :.: i :a~j..:';n :? ' '.*;..,, .~ -2.. 8..,3.' %..:.,, '[.. pa.&... h*..:. ~.: };:. s.e..~"., ; ...s

.. :.' 1f f ? ; ;u

.-~R.'. , V'g_i:%7 s,-; '. v '::. a ~,'.1 ; :. - -: an.

h' %
  • s C g ?. ?a,.<>.: a..X,c,es,%..:.-,. a. ' *..,: '.. wh.

....;;Jbr.lm c. :.'./: *ti " N~

  • ~ ;9 : 7:..

s +M::~.Q, s. . :ry. s.rv..:;,-e..m. a 2.t ::.,.p h..L.,..y. y: < s... ...e. .w, c;... ~, ? K M M,. :: W, ~.;+i. @ %.: % f %.:._ % ..';..g.. . :. -~ --%.'.M:4 s u.a l:-,:a.. : n;-'v..%. p : v* "f.m.: y < hs.., >,e M 1.. :.,. y r ' ~u

  • .m. 2 ow. d ~.

-t%'i. ::9,zi t. :y ::. c. W.t %. A...,;.M.,, ..Y. : y ;,;]',. ? :z.n,'A *:':.i.,.1: " ~,.- t >p., %... :>L};.n. '.-K rt -%;:7..* .,;' g f. M:4 M

'.
'm
W
-- m

.s.,p.~y.. 7 5*F. ~?%.W.D J,z -c ~~ . - - > ~... - 2 *. .m* h:.~

  • d *.Q:..;;si,n....

~, w.a-l. 7,;;; -:: s. W ' '. - u,a.r.q= u - 9

y. p:+C. ~ s:.,4.,,~. 7.g...-

. sg< e-.....,.. '., ' .g.n*.c.,x.<: w e-s <= a.

?,2; x~.-

.~.+~,s ,m...<,. 2.chk* $:,r;W,e***.-?= .W.,., x..?,,..' }:.'.C. ?,.: $~;'.p s % ~...'. e.* a -v-- '$.7. T '$ 3

-*C'":;Q. f:*$l W:
  • W *~if 5 W W

~.~;. sh'n. ~ w'.*y-HT~h' y ' 1 $~~ 3 (W.,z. :E'h.N: ~ .. % ~.---:.. 7.y~;m.=w,. *%. 2: 7 ~ ~ ~.W f. M. u: '~ ',,, M. e '. b...' .,.7. .x . r. q., + ". /J.. r."g l h**7,.f:". 42.6 <g. *- .. *,P : . f:* .y; 6.- c-. e'.,!,K.s 9. e.,- 4. ..a .(s. $"#.. a Y.N" **. .s. s s.# ' 7"'I" 7 - * -he' +*D ^ ' E ? 9.,.*% ,J a**F* ' 'd

  • s.
3. s..n.,;".#

4 ..u",w. e s.s,,., - .,, ; ?

. a.r..,r..,,.,
  • ~

.:.r. v..... r., a,... . an.. ., ;**.y%'- et. ..,1 ~. e a.~ g t s ;=~ s y' we. A.;g:.*:Q ; --_ s. p%,.'.'c^ f..f./*j'{ -* ' d

  • w ?.r.
  • k.i. *;'...*,~.'.s;.
~.*'.,
  • s

...~tg*.p,,3 -4.,. V.o, -.4' b ~. * :. e

  • d"

.J..,,. f,,, '.,2 .T.tiss. .esnt. e *. w ' *

  • e.
  • a,C" )

.'.l . bTl 4. *.U1M. 3 p. J..es Q*' *yu e., 6,1,f..*.**, %... .g,g k~';f' % +.sg..v.stL, a s s eb 'i%,se f. . we,d,.*;"',.,,,.,y, ; M

  • .s t'b*J* Y; W v %s-v.,; w. ':. '~~..* * *.:.... y, 3* '.

s 4 '.p.., rr.w ~. .. n ..n::. ;.rtvs.%, ~- e* Mi:

  • '..*; y*, I l t-M*j'=-;-3gt g,
"a i,,

~ ;.,'. *. .";r;, s

x..
  • f..,. '* 5 --,, -f "
  • l 3 i s',+*e;'3 '-*-l'.. p,u 6.g 1

.f.9..- ; '.7, 4 ,., J . s: ..s.a,, 1 ,.4 , c.u.a.. _-,. _m. .Q: w.. c.: r.+ , e. :; .m .r wn c,< .. -g... .~~v aw

,.n

- m; m-s

s

.$p. .[ D... I. te hp .((, .e b. SWT !. v. c.-NP'- 71 ./U,d Z ~. U !T'-l====pCL,n.Qw. '.i d:J.C.i@.?.'Q i ..-- + x p es -..r-. ,w ....u....e....x t,.

;s

,2.i,' m"'.?Ff*"d *'JU... .d. 3 - -n 7- .r, g w. Y ..Mk dC22: ' h !,.#..

  • *M.D*_. '

/ ..:w ".cc~- a1_ , -~ r - ::;; m ?:r-

\\

l ~; ^ f.h.w* h$. 5ah $.e$ ~ 3 _ _. a( R. &,--:e< ~.ur; p.ll[j'j * *

  • F*

~ m,. u V: c t.'c s*'%r W - [ eut* W T tf e. $*p a-~g 5- .-1ss.;r- +. J r.. Ek E' W *N$ r j t, hWYDh ' '

  • W :.:.a N 7 5.)W'"

Ib,S MMN.b'ND5NNh'Db fe.D. s W..M "&&@a%7g'i@[e MW 3 MIPd h MiE urge.@- wl.GW 3. Ot'Nde&.. w%'1 M [.:.X& &er-w q. ~ - -Mn M+ $:we w 37 5

  • lS & c -~ b.D$5 N v~~'~*T' Z m-t u %'U W 2 0 m M

m ..c h.: g %y&MY D*. M M

  • Q* &-

Q '.a' & - -fY l -6,,22 g% iw

=. ntpL. '*"* 5l p-.. ras. S

.2 ste s* '-. = - T w i.*d.s 0 i y*c e na

r,,

U-3[%yl*$$@@%m".l%$u'h MFA M%gne.{,glm M:- W.9-- g.,

  • d 3

96 %C.M

9~ n4 r~. n-./>

~- 4 k, [ m.g _lL@.d%$ $m [y c IIdd"[lifNNhD ~ ' _n a h d hel NE i hk U h ON Y'? M e k a wa w a[in$ ms m R w. i nemm hI%m@I M E%$ d Q M N M i M w % p as e s m a n d %s %g w@m M e w m e wowsmes i. a p. m S t. a. 9

s. m
  • .n m

van

  • ?

bhi &M Y: g$g?g.gep.g? rgmtgl.IWy,k ~~. ~~- rgi ) e v.. y 5 -f,;s[:..%..' ~. " _. a 1 c .... C.;W....* .. ~ - u~; .3...'. a 8* 1'.J. + *%.r.,,. 1, 4 4 g + r, -*

  • g i i

3 8 -~ - -.,-..... -. w-ay .--,-..----.,,--------s -m.

__ _____ _ -- _. - - - - - - - -fi60 -- - - - - - - - - - - - - - - - - - - - ~ - Budget /Forecut Vs Actual Employees ,,.~.- --- L.. FORECAST -- Total Site Dnployce l l:0 Year 1981 e- ' - " - - ' - - ~ " i e -l 2 'l:20 ,s ./.--... - TOTAL SITE DIPLOYEES t 100 Ij// - - - - - - - - - - - - FORECAST-CPCo Dnployees e / o'

4 l/>

300 ef i' ,.1,v } e,* 360 / i 1' a o 1 CPC0 D4PLOYEES e o w -z.::.,=2 l 1. ,I / e o N 31:0 o i es o m (l t o e i 326 / / t I -l e o ne t vs 3 Sg 300 .t s. .t i l c s f 3

i

.y 200 o 2 260 } 1

l 5

60 i 50 CONTRACT EMPLOYEES" FORECAST -

l

\\ ,--_-.----...'(---...---...------------ Contract Dnployees* t lio 30 ,e L ...~~. \\s,' . s i 20 ~~--~T' I b i II

10 I

.i ![ e. i I I J t i .l Budget ' Drown Jan Feb Mar Apr May June July Aug Sept Oct-Nov, Decl ~

to 8-5 bl.

Actual l i 1981 L i i 1 i. I 3 !" Excludbo I) urns Security Guardo i I mano.a .. i. n. _e

I ACENDA ITEM 7 1 I f CONSUMERS POWER COMPANY MIDLAND PLANT UNITS 1&2 JOD7220 . i l DESIGN STATUS 1 CURRENT FORECAST DESIGNED TO DATE %.C.OMPLETE ? LARGE PIPE 202,000 FT. 270,000 FT. '99 j i j, l

i LARGE PIPE HANGERS 15,350 15,170 09 l
.

r-SMALL PIPE 307,550 FT. 2 84,14 4 FT. 92 l r 8 l I i, SMALL PIPE HANGERS ~ 1.7,740 13,658 77 l I ,f, i .i ~ l l )'

-- -- -------------- mg PIPE HANGERS - TOTAL PLANT DESIGN CURVE ACTUAL AS OF: 7/26/81 JULY 1981 DESIGN 15,170 EA LEGEND .l ACTUAL

{

CURRENT FORECAST UPDATE LINE ~~ 17 l 15,350 EA' CURRENT FORECAST 10 I J... l 15 7, / p I j .O. i [ I o. 14 - l --- M E !lS El 13

i il

} 'j i 12 1 ll jj )l i l 10 l-o. I

i 9

. l ____ l l I 1 8 CURRENT PROJECT 5CilEDULE ,f f' UNIT 2 FUEL LOAD /83 i' UNIT 1 FUEL LOAD 12/83 l. 1980 1981 1982 1983 1984 8 dlt 1985 I I, 'c,

c..

..2~- -s, . s. + 2.- j . ' a.; ' " - i. ~, g_ s ,3', -l: _.;[ ,i: ?';'. 'l t

t I!q)/_ _ _ _ _ _ _ _ _ _ _ PROCESS AND NONPROCESS ACTUAL AS OF: 7/26/81 j JULY,1981 DESIGN CUnVE DESIGN 284.144 LF i I LEGEND - ACTUAL 380 CURRENT FORECAST I UPDATE LINE 340 'l I ~j 320 CURRENT FORECAST 307,55d \\ . f 300 l l N 280 1....- x F' t. / I i i e l 3 280 I i 240 l l 220 I f i t 200 r 100 l l 180 l CURRENT PROJEC'T SCHEDULE l ~ UNIT 2 FUEL LOAD 7/83 349 MT 1 NEL WD 12/83 l 1980 1981 1982 1983 1984 3 1985 l 6 ~. t .j n q

~ MIDLAND UNITS 1 AND 2 - JOB 7220 I ($M SMALL PIPE HANGERS (RcSident Enginocred)- TOTAL PLANT + ACTUAL AS OF: 7/26/81 JULY 1981 . DESIGN CURVE DESIGN 13.658 EA '} 24 LEGEND l ? ACTUAL 22 CURRENT FORECAST .....o.. I t' t UPDATE LINE 20 3 l . CURRENT FORECAST ~ -l ./ 17,740 EA 18 g i8 l=. o l .P t i. x e i4 [ 5 A J E i l I 12 --l I 1 10 6 1-l. -l 6 4 l h i 2 j-CURRENT PROJECT SCHEDULE i l UNIT 2 FUEL LOAD 7/83 i O UNIT 1 FUEL LOAD 12/85 { 1980 1981

1982, 1983 1984 1985

.A

i a CONSUMERS POWER COMPANY -f MIDLAND UNITS 1 AND 2 - JOB 7220 'f O[# cedd INSTALLATION CURVE INSTRUMENT TUBING - TOTAL PLANT ACTUAL AS OF: 7/26/81 I JULY 1981 INSTALLATION 44,690 LF LEGEND ACTUAL !f ...... CURRENT FORECAST ij --- CURRENT PROJECT SCHEDULE j -- UPDATE LINE 220 s y l ,,.... ' CURRENT FORECAST 205,000 LF i 200 l-l 100 f-2 4 l N 100 ,/ \\ ?! l / U 14 0 '* l-j .\\ 8 l ju. Ig 120 -l-j i { i 5 l -l- --I-l 100 I i V 4 80 -[- l' -/ l 00 -[ - / 7-I CURRENTPROJECTSCthEDULE ~ 40 l. t g UNIT 2 FUEL LOAD 7/83 8 g UMT 1 FUEL LOAD 12/83 I A l 1000 1981 1982 1983 1984 1985 i 0' 3 0 1577 33

,[,.m. TECH DEPT STAFFING PLAN 1980-1985 ..7,.. .;. :a, s- :- J. ;. u.. . wb, *,,. ... 7,t g ; ;'pt.g:-. O, ,... ~. '.

  • a $,.r,~T~f,,;.Q,.-/ r*

,. ) '; 'l'. Y?-* r i- ..'l'.:. A ..3.... ' j. , : ;.; ~,.* n,.4%_ ;;, s #y3. smi }. ~ ..O. ;.g.wn:;n.,..:.,:;q c 4.*. dg. *.. - w QQ. .s ? s .-~.a... 3 jp;g ,4.=,. .2' ,8 . n ..n-

  • ..gt*...,',...

T.z, ,[. f- . :.. ? *;.. e,y.$*. s.. ,.~..-p. r- - 4. a, ,,*u

q., s-_,

ca- . l -: ;. 9 '...y., r;. a.. s. .;d 7. . * *. :t. p; y.. -- .,e -.-;c - gr. ; ; *, e -2...-*~ -~. : ;.-~~, r.k b, = '... ., l: . -w..-

V '.L?0i'. * %~ %l l. r. **.'... ;;;,1. - > :-:
y. :..ny..;g?

QO - .~ ^ .. X... . 1.:,a,;.. we.Q..f. 3%y .....,.; J. r :.. .. 's;.: .'.*u.h.,..-. .e-

e..

p r-..,, n.:.,,...W + b,. ~ 12 0 : TOTE STEE g. . - :e...,s y . +.....,.

g. l. O..

,e r. a 5 s u*.:;. ~. .t 1 ~ ~ 90 - 80 - CPCo TiECH / 7O- --DEPT-PERSONNE I \\ 60 " r 50 -% 40 - i j 30 t 20 - l I i .t to = i l .~ .J .O u 1980 1981 1982 1983 1984 1985 f l l Visual Products Divisior mouw 1 St. Paul, MN 55101 Made ir . g

  • ee

-wb ..-.,-.-m-.,.g.. m p,.,,p,., y 9 m._ ,7


,-e y.--,

,e q QUANTl"Y ~ CHANGES ;. ^ (INSTALLATION) ~ Qoreccasr.# 7) ~ 6/22/80 7/26/81 b = i Concrete' 199,000 203,000 4,000 _arge 3ipe. 277,000 282,000 5,000 I, _arge 3iae -angers 15,670 15,350 (320) l Sma Jipe 310,000 3 0,7,5 5 0 (2,450) ~ Sma Pipe -angers 1 e,500 17,740 1,240 ns :rument ~u ainq 230,000 205,000 (25,000) Ex;3. Veta id Concuit 569,000 554,000 (15,000) Wire anc Cab e 9,600,000 10,300,000 700,000 Connections 385,000 385,000

.j 7, .-[ gg ci - - e3 3 co e ~ ~ " s e e2 m g g, "F ,c3 r s s uW a 2 .t, w g L ;;' a v n c) v. < o<< a n'y f N -" " 2 I o [o 9 a u. eo .c<<

g o-cN o

ssee p8 T-o o o c3 e N co N N N. a a g r z zz z g g c r T-- f oQk eg y a e c) v. eg y e 5 u g o er o ca e aoes c) t v g[' w g1-et q q m e. q e s_ s. c_ *l 0 U") E H r eeN s v-oaN

  • 5

.t oq gs pC o e c2 v-c3 N N N v a g.o ,F x. ,e 8 y z a< C N N N vjo " r e a e 9og e mosm < c) << G o o a y 'ap? o o o e es s vss s G u. Z a o g q v.m. q zqz2 2 r < O

W E

N c) sov o a 2 Q F 'h s (E

d 3

_J D J 0 0 i3 3m c' o o o e ca < v<< U 2 p< ^CO a - ~ r az c3 N o,- s s ca s s. s a v.a Z q%2 2 C q q v. q m. c .I g .i a t e3 3,_ y e3 a q o y y C@ [I a y v N c) Z F f$ I N o g@@ a ad ~ < F Na ya o oooo oooo o a v omev ,o o o o -Z 2 LL h s R q m R s.

m. q 0R 1

qw o e) N ses meom m aa W O< O G >- s a N N o mRe N a c) e o " r' om o o Sa C D gs b DOMaI U 2 8b 0 I v e oooo <o<< g J g3 5 e c2 v-ca e s o 's. s 's. o ovso zs22 2 3 H Lo n [, 2 el 6 ei 6 h 3D O gg d _<a 't ei ~ L W e-g to o o r-v. m a 2 @s d N N v G Z~ 1 ~ (; o Q U U t F U v o o o v- <o<< H

  • /".).

s s v s c3 soss s 2 r-o v-ee zozz z o h, ci o' i s' i ~ g" co c2 0 y @d-v a v y 3 a w l 3 J z 5

u.. u. < <
u. u. ' u. <

u. n .g Q..tI.N n - o aJ ww J J J w a d o z a 2 s l D g } d s E.$ e F o ,>m %j >G '? 5 k g D g +" C l y C o o o U J b p, ~2 3 g S c..e o 9 ea.o.9 ly e o o o >,= o c z e !a o f}C o c. {e. .c o. i z c-E c-E EF 3cE 5 e e o = c - o o 1 o e e e q U cec w 3 c. E. y 3 Su b s! o co c -e, c c x -a z aa 2 .4 c) es. n +,n i en ui () i.: ::: c) z u n -i

CONSUMERS POWER COMPANY MIDLAND PLANT UNIT 81 & 2 JOB 7220 COMPARISON: MIDLAND UNITS 1 & 2 WITH () WATERFORD UNIT. 3 \\ COMMODITY ~ MIDLAND 1'&' 2' AT 24 ' MONTHS WATERFORD 3. AT 21 MONTHS I-i ! % C'OMPLETE % COMPLETE i LARGE PIPE 9'4 l.' 95 I 'SMALL PIPE 78 4 82 LARGE PlPE HANGERS 82 84 I j SMALL PIPE HANGERS 43 N/A WITH PIPE i j C'ABLE TRAY j, 96 I ~100 CONDUn' 76 90 i\\' i POWER & CONTROL 58 57 I i TERMINATIONS 32 33 INSTRUMENT TUBING 22 53 i

~ CONSUVERS 30WER COVRANY Vic anc; 3 ant. Unit anc: Unit IL ~ 1981 CONSTRUCTION PROGRESS CURRENT INSTALLED INSTALLE INSTALLATION ESTIMATE 6/22/80 7/.26/81 LG. BORE PIPE 282,000-91 94 SM. BORE PIPE 307,550 58 78 1',350 ~7 4 82' LG. PIPE HGRS. 5 '- SM. PIPE HGRS. 17,740 11 43 CABLE TRAY 85,500 89 96 EXP. METALLIC 554,807 51 % 76 s CONDUIT WIRE / CABLE 10,300,000 28 n. 5 8. t. y: CONNECTIONS 385,000 20 S 32; l s._g e q j .G/M-0266-04 I-1 =. .-_y..

CONSUMERS POWER COMPANY n MIDLAND UNITS 1 AND 2 - JOD 7220 - DESIGN ND INSTALL-TION CURVES - A / SMALL PIPE TOTAL PLANT PROCESS AND NONPROCESS ACTUAL AS OF: 7/20/81 l JULY.1981 DESIGN 284.144 LF INSTALLATION 230,t100 LF. LEGEND l I j } ACTUAL l 300 CURRENT FORE [ht>T t l CURilENT PROJECT SCllEDULE l UPDATE LINE ~~ l

  • 340 i

i I: l i 320 CURRENT FORECAST I 307,550' \\ 1 i 8 300 . l.-- .d ..s** \\y-l,,..****, ' CURRENT FORECAST gj'* DESIGN j. 307,550 LF \\,6g, l .**/ CURRENT PROJECT SCifEDULE t i g 203,000 LF 3-200 INSTALLATION f 240 I '220 -l-f- i I 200 I / l 100 -i 1 100 CURRENT PROJECT SCifEDULE 'i l l l ~ UNIT 2 FUEL LOAD 7/83 l 140 1 UNIT 1 FUEL LOAD 12/83 1000 1981 1982. 1983 1984 5 i 1@X%$

,f3 Ig[ CONSUMERS POWER COMPANY MIDLAND UNITS 1 AND 2 - JOB 7220 fp DESIGN AND INSTALLATION CURVES 9 p), r pg'g LARGE PIPE IIANGERS - TOTAL.R ANT P f pg ACTUAL AS OF: 7/20/81 g h-kl./ DESIGN 15,178 EA JULY 1081 g -y/', ; a INSTALLATION 12.583 EA [ LEGEND v ACTUAL CURRENT FORECEST f CURRENT PROJECT SCllEDULE UPDATE LINE 17 4 l s' CURRENT ORECAST to 16,350 E-^, f j' k J.........- ]... DEsiaN 15 y r r* p* r a. f l<?r / o [ O. 14 - CURRENT PROJECT SCllEDULE-j l / 16,000 EA -- l-/ p 13 x / / 12 l INSTALLATION / /j i1 p -l- _/ l i -l-f 10 l 0 -l-l i ~ 0 CURIlENT PROJECT 8CllEDULE .l f' UNIT 2 FUEL LOAD 7/03 l UNIT 1 FUEL LOAD 12/03 i 1000 1981-1082 1003 1004 8 1005

,, : gn.r.....' 4,*,;fy 31 A,.g........ . :: :in:vy $,.. f 'C'ONSUMERS PdWER COSPANY .p n.. Vit ' MIDLAND UNITS 1 AND 2 - JOB'7220 4 i /.Af 'I l'8

  • DESIGN AND INSTALLATION CURVES 3'

i i 'i SMALL PIPE IIANGERS (Resident EnDine.drod)- TOTAL PLANT ,7... ACTUAL AS OF:; 7/20/81 JULY 1981 DESIGN 13,858 EA' 24 INSTALLATION 7,863 EA LEGEND I i i i t ACTUAL l l t 22 -l[ CURRENT FORJiCAST i 'j CURRENT PROJECT SCilEDULE UPDATE LINE [. 20 i l i i }; i l, l i CURRENT FOI1E. CAST j i-g/ i/ i7,740 a [ j 10 EA I -l. I i i i i l l i r i 3 e j j I i 8 a 16 -l, l i g

  • .*,.. ^

L t / \\ l I /,'.*

  • /

/ NCURREfJT PflOJECT SCllEDULE-l Q 14 7 ~15,500 EA g g DESIGN 8 // l \\. j l 'll ~ 12 -u i I. j,; 10 -l// -" A. i i 4' 8 / INSTALLATION 1 0 --l -b- / I ..I i e 4 I l 2 // n -- - -


i---

J -7 CURRENT PROJECT SCifEDULE, i I } UNIT 2 FUEL LOAD 7/83 0 UNIT 1 FOEL LOAD '12/83 l 1000 1981

1902, 1983 1984 3

1985 I

e-CONSUMERS POWER COMPANY \\!;f MIDLAND UNITS 1 AND 2 - JOD 7220

n i

IoE4l DESIGN AND INSTALLATION CURVES i ACTUAL AS OF: 7/28/81 EXPOSED METALLIC CONDUlT TOTAL PLANT DESIGN 600,411 LF i INSTALLATION 423.303 tf JULY 1981 - i. LEGEND l '-ACTUAL f,,. CURRENT FORECAST ~ ~ -CURRENT PROJECT SCliEDULE -- UPDATE LINE l +

  • I I

i CURRENT FORECAST - CURRENT PROJECT SCllEDULE 000 -l 534,000 LF I 554,000 LF (1) \\ 7 CURRENT FORECAST. ,.. e 550 i1, 530,000 LF (2)s l IN ............g*...- w~ 500 . =* . :x. / l /,..' i: /

/-/

o 450 7s.' 4 e j,.*...- / ~ U DESIGN / / M 400 ij l / / -l i 350 i INSTALLATION / / /

1) EXCLUDES G.000LF S/C INSTALLED 300

-/ -l- / l

2) SXCLUDES 30,000LF ALLOWANCE

/ ' VFOR ACTUAL INSTALLED VS / l 250 - - ~ - i / \\ / I j 200 -l-CURRENT PROJECT SCllEDULE UNIT 2 FUEL LOAD 7/83 l, .j j UNIT 1 FUEL LOAD 12/83 l f 1980 1981 1982 1983 1984 - 1985

CONSUMERS POW $R COMPANY i* .MIDLAN.D. UNITS 1 AND 2 - JOO 7220 .' el , DESIGN AND INSTALLATION CURVES [(@lt POWER AND' CONTROL WIRE AND CABLE - TOTAL PLANT / ACTUAL AS OF: 7/26/81 DESIGN 8.917,004 LF j JULY.1001 INSTALLATION 6,022,764 LF i LEGEND i i" ACTUAL l l CURRENT'FOREO Si CURR.ENT PROJECT SCHEDULE 10,300,000 LF CURRENT PROJECT SCHEDULE i, j UPDATE LINE r" e**[ ..7 n .i i i ii- '. * * * *./ N (7..* CURREl1T FORECAST CURRENT FORECAST % 10,300,000 LF 2**. / 10.300,000 LF 0 ,/ 8 8 / ~- / ' - i DESIGN f-o 7 }, [f s '3. I k ~0 -- f h-V y 5 I a j 4 .l_ INSTALLATIO l 3 -h t yp- -x// \\ ../ l 2 I I 1 l r-- i CURRENT PROJECT SCHEDULE I \\ l s UNIT 2 FUEL LOAD 7/03 .o unit i FUet LOAD i2iO3 1060 1001 1002 1003 1004 1005 l G1584 e

9 w O z F- =*: c2 = -s z w =c 2 n_ =2 ~ C;3

  • C a

W m m =c J c.s em Z Cs H g2 M E D EO

  • p CD E

"C Z

  • C C/3 j

c.s c.s n cm C.3 E p 2 p L.1J a cc W z o w W oH w-J p, m ~ C cs_ LL., c.s ca 2: E mc =s en W cs cc o a '3 F-- w l aC g Z E z l O W cs 2 c:3 l g CD cs F-- W4 c I C/D =) 05 =C =s W cc

  • C z

a c.= C.s c.:s co z CC z 2 O C W cs c:a gg c.s c2 a c.,3 Z S S S S e 9 O 9 = e _ _ _ _ _ _.,,.. _ _ ___ _ _ _ _. _ _ _ _ _ _. _ _ _ _ _ _ _ ~ -,.

i i' 1 1 8 / 11 2 / 8 2 1 6 7 E L T E E N L A P P M ) O 6 1 T 7 C S A T T C N S T A S E E A C R C E C O R R E F E O R e F O P F I D I S A N S O O H H M L I T M E C 0 0 S U 0 0 A R 0, 0, C T 8 5 C S 6 5 R N 0 6, 1 1 0 H O 8 8 3 4 C 9 9 4 1 1 E Y-N L U U J J e !l l !h:l lF:l iJ I 1' i, i

j 1

8 / 112 / 8 L p E T N R A N Y O 4 P G L P I G R P n S T E A U o E E OV I S S S i D B A H c) E U T t TJ P T R C T uS O S E A rK P D P R N I p R t L N P E O P O sU l I A U V F L nB ' L T 3 S O A N N N A o A MI O O R O L CA L D C S T T U I G T A AI H A DT T G AN T L T N I N TO L S L L nA L I I N A N L I R g lP D A T E C I i L T A U EC S ML T P I S s I N e U N U L A U E l A B R A I D X D TT D L H C C N B S S E C U N NN O A A A M C C H I I N 1 2 3 !l il!L : h F ! ! [ 'l' ll jll l

l 1. l HRC CASE LDAD FORECAST PANEL L LONG LEAD TIME ISSUES Path B i e NUMBER OF ISSUES o

  • JULY 1980 44
  • JULY 1981 47

]! L e ISSUES WITH NEGATIVE FLDAT 4

  • JULY 1980 15

[' [

  • JULY 1981 16 i

i i

l J-l

HRC CASE LDAD FORECAST PANEL t. LONG LEAD TIME ISSUES e lt Tracking Program i ? USE OF CPM PLANNING & SCHEDULING METHODS lP/2) [" e PURPOSE - ESTABLISH PROJECT PRIORITIES i- - EXT,RA VISIBILITY FOR MANAGEMENT REVIEW & ACT10N ji i. e ISSUES COMPLETION TRACKED TO ASSOCIATED SYSTEM T/0 DATE j l IN0T FUEL LDADI f e T/0 DATES ARE OPTIMUM - ALLOW FOR EFFICIENT TEST PROGRAM 1 e VIGUROUS PROGRAM TO RESOLVE SCHEDULE CRITICAL ISSUES PRIOR TO SYSTEM T/0 I l l i l l

,e ab 7 -f 1 } x %a i s a z I ma: c/3 c2 W U W D gsy

  • t 4

/3 p\\ m SW \\1 d W

  1. -t 15 8

e2 c-W e m a W n cc 7 a o g d o 4 .cc d m ~ m E cW .d a W g3 E 7 J CD E W LLI v .=c ~ w mg W 3: o cc ~ 4 w d O g m m C y J o m a Y N g o w M g W e G 2 A

3 E

O e 9 9

__m,

.,_.--.,-_.,,_..,,,,-,----_--,_n--,-

~j-NRC CASE LOAD FORECAST PANEI h CRITICAL LONG LEAD TIME ISSUES o q IAS OF JULY 1981) - FLDAT IMO) SYSTEM ~ T/0 DATE

j MORE THAN 6 MONTHS NEGATIVE FLDAT*. [2]

h

11) *MLLA 6A FIRE PROTECTION SAFE 9-1/2 BNA NOV1,1981 SHUTOOWN 4
11) e MLLA 21 CORE FLD00 SYSTEM 9

SAA DEC 1,1981 I N l __ T0 6 MONTHS NEGATIVE FLDAT* 15) I' 4 lel

  • MLLA 68 PRESSUHlZER HEATERS 5

SCA OCT 1,1981 [ l11

  • MLLA 2305 COMPONENT COOLING WATER 4-1/2 EGA DEC 15,1981 U

lI L

  • MLLA 67 OVERPRESSURE PROTECTION 4

SCA DCT 1,1981 ) AT LOW TEMPERATURE I !{ .

  • MLLA 6 FIRE PROTECTION 4

RGC MAY 1,1982 !. l III e MLLA GSL CORE FLOOD DEPRESSURIZATION 4 BHA MAR 1,1982 D

  1. Negative Float Relative to System Turnovers Dates lillssue Requir.aslest Workaround ICWG Action)

~ @0.55181 Schedular im'paci~'liii~pactsQ,_ s 8/2ii/ai

[ j i ? !l 1 3 2 1 2 8 1 2 1 8 2 E 8 T 8 8 9 8 8 8 9 8 9 A 9 9 1 9 9 9 1 9 1 1 1 1 1 1 D 1 0 2 0 1 1 1 / 3 1 1 1 1 1 T R C H P C N C B N A E P E E U E E A M D A S D J D F J M E T C A K A A A A A S L C G B C J C A ] D Y G B B B B S B S S T N c ) LO O EC M 2 / N 3 3 1 I 2 1 1 1 1 1 / AS T 1 1 P E A D s U L S e I t S S F C a M R N ) O O E E D A S1 G O V D I 8 I r 9 N T L A e t E R 1 O A A R v HM R V G o L I Y E T O P n UI L E U T ur P T N A B U Z T N Y L M N T A J I I U D P R C O E m L E F U P s A A N N B T M e O S O m U E W E S G R R G S E ts o L L S O E R O D N Y C y l A S A S i I D R E H R L L t G( t T P M C H P R P o c d N ] 9 U E N D M H E a t H D E nO A D R A [ e p A v m S b L L S R C i N N N i t X E N E O b L T W W S W T a r nA A O O S O N W T L U a l A e l C D D E D E O U K R u D nI L S T T V T D D P A d T M E t F T U U U C U O R o h a e T I R I E R H H H C H C B l c D R V A S S S A S F S I T T L C T C - D D C D T D N L e l v e A A L L A L S L A A 1 i G V O O E O O O L M 5 t E H C C R C P C P S ga 5 N e 0 S 0 N 5 H A D C 6 D 0 G 0 l T 9 S 5 4 S 2 5 3' 9 e N 5 S 6 4 B 2 6 2 6 l O A A A A A A A A A M L L L L L L L L L L L L L L L L L L 3 M M M M M M M M M O e e T l l l e e e 1 l t l i [I :

j Hli4h!

<;i Ll l'i l i I f ,\\ i!j

a - s s. m p _,@a, ,Ohhh O 4 9 m =,- N CO G3 m gg 2 D cm =- E ~p a u W 2 "C CO g c=> E <m I w 4 g m CL Cn en cm C H cm 2 b C/3 C/3 2 32 CC m m o => C3 ~ at: C/3 p 3 cm w CC w O2 E H c,.3

c cz

WW W cm =C .sg

ng E

M sc CC E E C=> gg. cs E cc: c: O O LL. H m Hw c2. cm w 3 C.:3 w 2> cz: 3 H w: cm 2 cm C3 C2 at: E Hc cm C N < at: cm ca. ca > T o w.3 g G E cs p c c6 2 m m H 3 w c:s w c3 cc E y Cg 2 C4 gg g= c3 Lu C23

s C u

C/3 2 ca H H W cL. c.s ca. m = w= 4O CO c= 2 c. C3 J g3 c:t ac g3 a a ~ m cs n 8-w w M w c_., m -c m c= _, =- ::- =

==- EE ,o w =s cc._ >< W CD w J CC l-- CL acc W C=3 3 Cs 2 g e = m ca c=> l C3 cc CO H" c,:s 2 W c3 A M cL.

== Cn l gn E =c w cs H. Cc C.3 1 s l l

  • ~~e+--

--"'~* ~ ~ ~ =-g------r, ,gww-.9 + w w,.g-ww- -..g.+, ,.-g .p-.qw,mwe-yr-.g,,.,,r,..-ww.-9m v y,,ww-ge---yww-,e-v,wwr-,my-ww wy wy-wwww mm.- s.,--.v-w w .s--

[ NRC CASE LOAD FORECAST PANEL l i LONG LEAD TIME ISSUES u i Bottom Line i p l i g ALL LONG LEAD ICRITICAL SCHEDULE) ISSUES

i u

CAN BE ACCOMMODATED BY THE USE OF PRE I t DR POST T/0 WORKAROUNDS AND MAJOR i-l MILESTONES ACCOMPLISHED ON TIME i- ),. ) I! 1 <l.

w 0 .4 ,m., 4.. -=M4***'# ,m.s 2e ' * '

  • 4 A

O i F h t 7 ed H to c.,=3 i 2 c.s ,,,) N 2 gaa : 3 M ll25 E3 m .g LLI 2 A 2 c:s ~ C3 H H C/3 c.s C/3 D 4 2 CC$ 8 .t G3 LL3 a z 3 CC >1J

== cs C L 53 C:3 a lE =s M LL. A g - m c= W

3 z

g C.

C c:2 w

aC C:3 H C3 cc: g c3 m en CD C u w w c:a es: u A 2 w =s g LLJ c3 E -.J u

w::

es C/3 - c.2 es cE: M cc cs o :g 2 W k N

3 es

= = = c.3 cc:: H E O cc; p C W -cc Z C/3 m H H w CE: Cn w 2 H a wz C:3 m E ~ o m o =, = = r c en W C e S S 9 m O 4 e 9 _.gpe.p.+W G "NN O esM***

. c..._. Mu' 75 20 MIDLAN D. PROJECT. - ~ 'inino REv1. owJ i .~ .15 T Y P.1 cia 6. [F.6 RECAST U: SCHEDULE. STA R T'- 0 MS U B~--SY ST E M ' S O H,ED;U GE ' ". RITE'R'IA. ~ 8/E EKS.TO 5/ U SUB-SYSTEM TURNOVER 3,0 2,9 2p 37 26 2 2,42,3,2,2}l2,0 1,9 1,8 1,7 1,6 1,5.1,41,3 12 11 1,0,y J.T ? "~.1't,f 'I o s s 8 8 I..' ji: ;,jg l; hh p ^.. LRG SML .I o s, 1 + VLV' PG - %l p X 'l i PIP,M ;,. j 5 (S i .? EOPT pg. IN3r ?ll' (NG ? l i .t; n.,.. 3..,e i l t. t t u,. i., 1, .I. l r e ; g'- I [ r'- h;,_ i i i {i@.n' M:,' i eg Q 3 k'il.

10 i

J . R EVIEW to i l 0 op

a. 3
FINA tu I. g$

~ of S U D-SYST. Dr ' REVIEW SUS-SYS T. REVIEW D E o PUNCHL o 3 d. DETAll SCHLD. MONTHLY SE DETAll SCHl.A N 7 $I D WORKOFF 2 i i tn ( -

M COMMENT byf; I

xb2 WEEK LY 'a zo j O ' << [. i 2( t u;z i n. oo

a. 3 bI !!l-W j D ' D,,

b [ i r 1 t hl

l ~

a i l-l s e l . I. .: i l 1 i

.5 -

i t, i l A O ~ l' ' 'j .;g [, i-i,

g. 'l l.

-[. s' i i.. - s i: I' i. l ....l. i.. l, ,'i.. I. I 1 !,. * . i ;. ....,.....~.!..l l- ,. I i i,. . i '... j..

uil '..,-i.l.l.'li,.

.i -. I ,I; l .;llji..l

8.,

-l llg .rb .,.i r-i .j...-; i ,,... l .. ::..,.,j. l. ; i:,, l .i i -;li. .gi, .. ;i ;. j.. - .i.

1

.!.l..

.. !'l l..l a.

. t. e .11 .I,,; .:1:,,. .l- .I I l i; j. t. :.;-i :I ' l 8 ' l- : i, I .r ., l l,,.,...j. g. i-l, ili i !II.i. l 1. ! i, .l.. fi .g8L. t i... .1. I le ~.*

U. % :-t * -~2'- t . ) g-e w t, e O 4 =. O s

O N

d b Q E ~ oC - f< ~- P iwN c-g c .g ,r-a s., vi +., v+ c 0 ... e o ',. 9 e 9 O_ CONST RCCIICN COh1P'.E TE 9'2I-SI ? M O O c.

    • .p g

e -c O e O e s u 6*<] e-r e / w a-e a.:w 5 m n+ a F)i 4 e g ?:4 m \\ c.l h t-5 ~ ~ b 3 c =m /

a. u s

ss .s_ - 1 e z o a> 4 a w s w: o 2 ( .c z e Q 3 o w gm q c o {, E $ ) bb a y jp m q,a C7 Ee m O 5 a9 - ~ Po ,=--i .:n f . -i., ' d << ^ w a e tO e.. .t c 1 [ e ur ca c -f a u

g j

a e e-d 2o l N s s o N r c c0 0 6 Ci d h* l M 7 rC 0 1 m N. L r 'y ,. E_ r -- e = .m D S' - A m '- e C D ..g ~ T u 4'., -di-v -s N = ~ g-c3 c2 w a o

2 g sr/ y '. Ls e

O E 4 3 = e3 = e3 w w w w e D w E; c .o P 2 a c 2'

5 '

c C -d t_ C: O C C - = - c.= w Eu = a $p <2 i g x = W 9 t.a o o t- .y = a= O 3u ..r-o 3 a = = q, s w

t
c.. : >

r = > = 5 .u s s a = .. c3_ o,,._,ti a _s s-C O D.D

  1. - B:

w h.O a.

  • h L-

- '$--D-c. c = a.o a '.a a a = 2 c c -o a w a = r L, =f-o ya o n_ c e e c s

  • o

= a o = m ,. t- ..:;.. o .a a al o e o = . =ag. u. e c = 4 .<. e s.,:E s-.x o y _a = - e e o a r u o m- \\ $\\ b,= c\\ o,5Tst R I W n, l _--._ldj l l-f .l ..l ~_l l 2 l .l. - l - W )- I. l 1

- l l

I . O. I A 3 ~* i G. W - I

4 ', i.ii

  • l',

5 li i ' ji!l\\\\I 0 0 0 0 0 0 0 0 0 3t s. T a. G 2 5 5 4 2 5 5 5 5 T O 7 7 1 7 7 7 7 7 7 T C U t E E E E E E E E C g W D.g O ETA B O O O O O O O A CR O O O O O O O AO T C. \\ PP LK E P$ RoMA OT 0 t 1 C O. ~ .TT I C 0 .LE VEL 9 RE EU S O. 8S IP 8 0 8 E R 2 U T F F 1 F A F F F F SRS 0 1 2t 3 2l S t 1 1 2 22 2t 2t 7 SON 0O Eo O Ro ON 0 0A RA EC RC 7 IF O NN FN N HN l 8 t tNJ MJ FD M0 NJ N O C O O 4 t 4 t t t 1 t t I t O3 O3 O3 O1 O O0 O0 OO O0 E U D SRE 7 6 SOS 2 6 IFU 1 3 W 8 E E N N U I 1 SRV O J 5SOE I S 7 S S 5 IFR T E 3 E E A L l L L C B O B B T O AJ G A R A s L L C7 N C O C %P 3 2 FF 45M W Rl R 5 R 4 7O E OO E O 23 OO C N FG L F 5t FS N B CO A T O E2 A 3 E 2G E3 L T D C 3 D N DO %P A0 S AF &2 AO 30M J M8 R Y 2M5 MT O. 3 5O 7 2 O H 3 2& S D 2 C l B3 .BO CF B2 J E1 F P tEl 5 EN L E B. &T1 T O 8 O X C S 5 A8 L G ON 2 S UON 3 O X t D/ %P N T2 5 L AT2 Rl TG U P425M 2 C A OO 2 A 2 SU1 2O T& 2 T / C 2. 2S 2 2. T& FG T& 2 2S 2 N &S 2 I Y7 8A &I0 &L 8 &IF .I IA 8 NL0 1 C I L7 t N 1 1L5 t 0 1L3 1 UU T F F 2 F P A A 3 F 0S F O F F J RK l t SE tt S 1 tt S 1 I S 1fS l IS SME t 1S .O t tI l t S D-t AS CETT oETN3 EET. CNT CNT UETNO EET L oUTe T EUT N-TA NSI NO DSI V 0JI 0dI ADI NG 1 1 t A1 ST 10SI U 1 0NON D0I LB NAI NS 0AI 0NO 0NE 1 t N 9N NON NNA t I NON tt N t 1 t t 03UR 03UC2 O3UR 0OU 01 U OOUCI 00UPC OOUCI OOU L. DV ) I E MR E L 9 3 U 4 t 5 9 D t t 3 8 E A R t 8 R E E / H S LOO R E C O R R 9 C E LNF O 1 A F O R O R 2 S T M F R 3 F O F O / A Y O t Y F F 7 K D N W T F E W T5 T1 O C S C S3 S S6 5 N O ) I R I D R R I 1 O I

3. G 0

U W A T L 6 O 5 O 1 L 6 O 5 L 0 5 R M ** t F 3 1 1 ( P t M 1 8I N 1 G I 0 1 S N1 L L S T N2L 5L 4 5L 8 L C N L R0PT2Y N2R L R 0 Y T U N1 R L3R

3. T R

L6R C t I AS CSCM1H O1 T N T / H N O O .T N1 T a N3T A N UT S CEP CEC P C L P C R C3C P .C C7C P C TN E 2 - 3 - 5 - 0 - I A CE O O& O& O1 O O o8 O2 O3 O5 8 M AM T T T2 T T T. T1 T T 3.+ C E M K 9+ 96 t + + 1 + 9+ .+ 3+ A R DO S V1 8 V1 B VE8 V B V30 V1 C V1 C V5C V7C NC AU EiC E1 C E C E C E1 C Et C E2C E3C E5C T SA T/OREA REA R&A R A NEA* REA R1 A REA R3A S SN E I T)S L AFN T L H D(O N P C I I M N eft AM O U L$C RO C P UAU TR DCR SF M EET E 2 2 2 2 2 2 2 2 2 E HRS R PF YF YF PF PF YF YF YF YF T cot 4 A - M-IM-A - A - M-IM-H- H-S SFI P t P P t t - t - t P P 1 P t P Y OA OAC OAC OA OA OAC OAC 0AC OAC S O 'E - NENE R NIN E I RILI B Y EL L M C-D- F - 8-C- D-F - 0-F - S EE D U 2 - 2 - 2 - 3 - 3 - G - 6 - 8 - 8 - - NT O N 4 - 4 - 4 - 4 - 4 - 4 - 4 - 4 - 4 - T J t 0I SoR 0-O- O-O- O-O- 0-0- 0-R 7GRcI K 0-O- O-O- O-O- 0-0- 0-O 8NI EH S 1 - t - t - t - t - t - 1 - 1 - 1 - S EEFST A A T E - E - E - E - E - E - E - E - E - ( = l:l 9 jl

)
  • h j}

,tl'f! i'

6:

- l 1 -! 't '- li

!dTAllT-UP SUPPOR:I LIST ~ SUB SYSTEM NO. 2EAC 28 C,; i CONST COMPL DATE- 09-21-81

, l[
I I

j' REV 1. i

  • 1.;..;Suli System Title REACTOR BLDG. SERVICE WATER i.S_

I I l' i DESCRIPTION RESP FCST DATE REMARKS j i

5. I NCR I 2008 IIANGER EXPAtlSION ANCNORS.

SWENSON F DISPOSITION REQUIRED f .jf ' '. I, NCR # 2677 SWAY STRUT VENDOR WELDS. SWENSON F CONSTRUCTION I a I FCR # 2920. UNDERSIZE WELDS. SWENSON F CONSTRUCTION i i 1 1,tiCil # 3046 PIPE SPOOL PAINT. AA 8/13/81F j i

},

,,ilCR # 3131 Sil0CK SUPPRESSOR BUSilING. SWENSON F CONSTRUCTION t NCR # 3174 SWAY STRUTS & SNUBBERS. SWENSON F CONSTRUCTION i NCR 1 3276 PIPE IIANGER MATERIAL. AA 8/15/81F ltlCRl3277 PIPL llANGER MATERIAL. SWENSON F CONSTRUCTION , Nc R 35W tWAPMOVED MA TERin G b4 PPUER, SWEM F I CONbTAkLYlOA)

6. ' OELIVER IN llCATORS 2TI-1956-2 AA/

9/30/81F J-204-AC-Q 2TI-1957-2 REIGELSPERGER/30/81F ITEM # 17.35 2TI-1958-2 9/30/81F [ l, 2TI-1959-5 9/30/81F i.

3 T

o 7. DEllVER TEllP; ELEMENT-SURPLUS 2TE-1956 AA/ 10/9/81F r' ^ J-233-AC-Q 2TE-1959 REIGELSPERGER0/9/81F j'; ] ITEM # 47-2TE-1958 10/9/81F q 2TE-1957 10/9/81F o L l Is l e 1 ~ !} J ' G/M 0100-01 page g of_ .3 g. .I i! s e

d c IERI ERHER AM EI AIH1 AE R E RR E C all R E EL E E A. TOTAL NUMBER OF PROCEDURES REQUIRED FOR FUEL LOAD 412 B. NUMBER OF DRAFT PROCEDURES NOT STARTED 100 C. NUMBER OF DRAFT PROCEDURES BEING WRITTEN 20 D. NUMBER OF PROCEDURES APPROVED 28 E. NUMBER OF PROCEDURES IN REVIEW 292 F. TOTAL NUMBER OF PREOP AND ACCEPTANCE TESTS REQUIRED FOR FUEL LOAD 340 6. NUMBER OF PREOP AND ACCEPTANCE TESTS CCMPLETED 0 H. NUMBER OF PREOP AND ACCEPTANCE TESTS CURRENTLY IN PROGRESS 3-I. NUMBER OF SYSTEMS TURNED OVER TO START-UP: 851 ' SYSTEMS TURNED OVER 214 PARTI AL SYSTS4S TURNED OVER 3 ALPHA SYSTEMS ~'.J47 -r 4 p g g t&w-' -- - 7 - - - + - +"~ T 9 ~e P -Nr

s i - fI ~ MIDLAND UNIT I AND 2 PLAN FOR TWO UNIT STARTUP l .I i f, DEguLVE PUNattl5T DESOLVE FUI608tlBT 175848 l ITfHe Nrt UMlf 3 FUEL LOAD UNIT I l U_& IDAD e. p...\\ \\x

n..

g' ) l. l .0 i NT pt0 N[T POST FUEL IDAD I 3 a 4 5 6 8 9 % to l s kiDao I Il a f,. l 3 5 p)rf 4,, & 5 .; L .a I I I I e .' g s...,f i 6 s e ,5 ,i e SESOLVE FullulLIST kt90L18 FUNOll.lST ITEMS { !' ITEMS RFT UNIT I I PUEL lAAD UWlf I .) / o? ' 'd' /e' r. { 'j . _i___.i L e i _i a a a a = a -

  • a a

t a a a a a a* 0 2 4 4 8 le 12 14 16 le 20 21 24 26 II 30 M)HTils .i EMERCIII, Tt.U$ll, I f FT B SEl.INE 4 NYDRO & COHr. TEST BCS HYDRO FHASE CD/ N CYCLE CLEAMUP 3 EEFAS TEST PMASE 7 1907 FUNCTIONAL TE31 ] FutL ICAD Patta 8 i AEM)VE HEAD 4, FUEL l#AD 9 .l.

  1. 8 I L

SIT /lLRT FilASE 3 AcTITlfle's (ess) 10 J y

~# PROCEDURE STATUS AS OF JULY 1981 NUMBER DRAFTED APPROVED TEST PROGRAM-GENERIC 47 72% 57% k}{g. ' 72 62% 15% EQUIPMENT SPECIFIC ACCEPTANCE + PREOP TESTS 340 73% 5% OPERATING DEPARTMENT 355 89% 73% t MAINTENANCE DEPARTMEE 340 81% 69% CHP DEPARTMENT HEALTH PHYSICS RELATED 158 58% 15% 71 89% 75% CHEMISTRY RELATED ADMINISTRATIVE DEPARTMENT 95 100% 60% i 1 I l l l e

s% ~ l 1 t 1 l l !u l j l STATUS OF. TEST PROCEDURES h o TEST PROCEDURES REQUIRED 412 1 TEST PROCEDURES DRAFTED 292 i (70%) l e PROCEDURES REVIEWED THRU TWG. 57 l l.!' -ONLY 273 MUST BE REVIEWED BY TWG, (21%) l i i TOTAL TEST PROCEDURES APPROVED 28 l l l (7%) \\ \\ i I

I i

'" s, s C o ~i CONSUMERS POWER COMPANY 7[4 CPCo SYSTEM TURNOVER SCHEDULE MIDLAND UNITS l' AND 2-JOB 7220 4 i : 9 l- /xpfp \\ p i 1 i 10 0 ~ 90 e p e i-l i 80 d I' y 70 - = j d 60 / l so / l q l o / i O 40 / b ao I Fo 20 NOTR / I' a ~ 10 ACTUAL STATUS EXCLUDES 4 PARTI AL SYSTEH TURNWERS t 0-I i i N DJ FM AN J J A S O N D J FM AM J J A S O N DJ FM A M J J A S O N D J FM ~ ,~,,

!I i, i i L ELECTRICAL STATUS 4 i l 40% ENERGlZED u ll i l^ PROJECT 60% ENERGlZED L i l BY YEAR END' o I I l i 1 i l

e HIGE PRESS:JRE BOE.ER PROJECT V _ES~~ONE SCHEDU'_E Or ACT VT ES: 7/ ~ 5/8 START CIVIL CONSTRUCTION 8/3:/8' START MECHANICAL CONSTRUCTION 'O/23-1-/20/81 BOILER DELIVERY 11/15/8-START ELECTRICAL C O N S.TRU CTIO N l 2/1/8"1 COMPLETE ClV!L l CONSTRUCTION 3/1/8~1 COMPLETE MECHANIC AL CONSTRUCTION 4/ ~ /81 COMPLETE INSULATION 3/1-6/1/82 TESTING AND CHECKOUT 6/'5/82 OPER ATION AL l l f l .. -. = - - - = : z- - - -

^ ~ ORGANIZATION STRUCTURE OPERATIONS SUPERINTENDENT PLANT SHIFT . SUPERVISOR ENGINEER SHIFT SHIFT AUX OP SUPERVISOR SUPERVISOR SUPV UNIT 1 UNIT 2 R 4 9 .- + e 1 w m mosm - ,--,q e - vf -e t - --rm-. -mw7 '= 7-w-w

c ~-_ - r, STAFFING ASSUMPTIONS PLANT SUPERVISOR, 1 PER SHIFT 6 = SHIFT SUPERVISOR, 1 PER SHIFT PER UNIT 12 = AUXILIARY OPERATOR SUPV, 1 PER SHIFT 6 = SHIFT ENGINEERS, 1 PER SHIFT 6 = PLANT STAFF WITH LICENSES + 10 SRO 40 = .0 CONTROL OPERATORS, 2 PER SHIFT PER UNIT = 24 EXPECTED TOTAL LICENSES 64 = 1 J )

w-. e s eppeeh Wge--es e n. apa.. g-m, ..%.4eg.g.we %ws y_g ,pp.4 . w e w. % p_wgj,.% g 4 39 + e +

  • O k,

. t,, N v t, h N t! 4 Y. t u. Ty d O_ d / u ~ s y c / t t s Q h D s g a . q4 / b h Y / v 0 i / a y e W C o 2: 4 b Q / D Q. / d O ,4 / m O N ss s 3 / I l l I l i / / Q 9 e / d.. [- - - -:~p -p

  • /
  • ,/

,/ ~ c(- -.- -. - - - - e / e. O Nm m O o O O O O O o h t M N Q d u T ?.? A01c!v 9 '.2d 3 C 4 t'/.LY2!3d Q do 7.!2 2 w n/V

PHDPDSED LICENSING SCHEDULE FDR THE MIDLAND NUCLEAR PLANT COMPLETE START ASLD OPERATING DRAFT ISSUE ISSUE O.L. LICENSE SER'S SER SSER HEARING - DECISION ISSUANCE 10/81 4/82 7/82 11/82 8/83 7/83 \\ RESUME COMPLETE PR E-HE ARIN G COMPLETE FSAR FGAR SER DOCKETED CONFERENCE O.L. REVIEW INPUT llEARING 11/77 4/81 2/82 9/82 3/83 [. 41 mos 6 mos 4 mos 2 mos 3 mos 2 mos 2 mos 4 mos 3 mos 1 mo 4/82 7/02 C) _S _D 0" b Cs, p 'j 0"- P ACRS DcQ MTG &7 ISSUE DES 1/82 V FES 6/82 l I' TJS 8/81 9 i' O j i

g. ._u 'MID' AND LLCINS NG STATLS 1)DCKET 4 FINAL SAFETY ANALYSIS REPORT ~ 4 ENVIRONMENTAL REPORT 4 SITE EMERGENCY PLAN 4 SECURITY NRC REY EW O BRANCH CONTACTS 4 dUESTIONS/ RESPONSES. S OPENITEMS SAFETY EVALUAT ON REPORT ENYlRONMENTAL STATEMENT NATIONAL POLLUTANT DISCHARGE ELIMINATLON SYSTEM 'ERMIT TJS 8/81 3e-wwr t e e-w-r-ywe.v y7--- w w t-- W--gw gasrvn e-- * - 9 -a w e-- wN ey-y* y r--v-w w e' e+ w e we--*'re--w m

^

~ =._. I NUREG-0737 REQUIREMENTS g g pg;y?? M 5 " 9 RCS VENTING O AFW FLOW INDICATION O HIGH RANGE RADIATION MONITORING i S INSTRUMENTATION FOR DETECTI'ON OF INADEQUATE CORE COOLING G EMERGENCY RESPONSE REAL TIME DOSE PROJECTION 0Y G N.; 1 .c

q. e a

p,.s@;;;l? Q Y~ e? ' 3'yq T TJS 8/81 y------ wy--- -.-w-wv Wr Wg -q-m-y -gtv wg----y-gr weer = r -*r*"yw yv--y-Vw --*gu--'2-tw*e e ww


r--

--y-tP' - - T '-T

1.,0,. ~ t ',,,0 p. 1 4 'r 'i$ lh A,w, '/ ?% d p,y.il g c 'N, OTHER LICENSING ISSUES .p .7 9 SOILS O SEISMIC S EQUIPMENT QUALIFICATION l 9 FIRE PROTECTION TJS 8/81 -w-w---7 m-w.--wg ,--,we.*v-c--- --tv-v- - * - - --t, t y-W+, y--w-- ew--y-r*mg g--+e--'e me,wr w--w-ww--v--g-- -w--

. s SNUBBER STATUS 1ND SCHEDUIS AUGUST 25, 1981 0 There are as of this date, 8 snubbers con:pletely installed in Unit IK 1 and 25 cogletely installed in thit 2. In addition,' there are 8 snubbers pinned on one end in Lhit 2. These latter pinned snub-bers will be completely installed upon resolution of installation interferences. Tne schedule is to complete installation of all snubbers in both-units by the end of November 1981. At this-time, snubber installa-tion is not a constraint to constmetien or testing. ~ 4 l i-e i s l l

2 ,/' ~ ' TECHNICAL SUPPORT CENTER Started construction on Civil / Structural portion August 10, 1981 Backfill material has been placed and forms started on' August 26, 1981 First concret'e placement scheduled for August 31, 1981 r Civil / Structural portion scheduled for completion by December 14, 1981 with a total of 1,000 CY of concrete required N g Status of other items: 1) Approx 15,000 LF of cable will be needed 2) Charcoal ventilation filter is on hand 3) The Radiation Monitoring Equipment is ordered and slated for October 1981 delivery 4) Distribution Panel and Transformer, required by January 1982, is still in engineering 5) Computer is ordered with delivery March 1982 6) Radio Communication Console, needed in April 1982, is an off-the-shelf item E 7) Uninterruptable Power Supply System, needed by' June 1982, is undergoing bid evaluttion 8) The Radiation Monitoring Display, needed by Nove=ber 1982, will be an adder to an existing Purchase Order No problems are currently anticipated in meeting any equipment need dates Completion and testing of entire facility needed by February 1, 1983 l i 8-26-81 JSStrahl I I 1 l /

-. - -.~. d 00hTAIMENT OUANTITIES AS OF AUGUST 1,1981 UNIT 1 ACTUAL TOTAL FORCAST TO GO LARGE PIPE 11',700 13,200 1,500 SMALL PIPE 16,200 19,300 3,106 CONDUIT 26,000 26,150 150 - WIRE 6 CABLE NONE 200,000 200,000 (200,000'/init) (start 9/1/81) UNIT 2 ACTUAL TOTAL. FORECAST TO GO LARGE PIPS 11,560 11,930 370 SMALL PIPE 18,300 22,000 3,700 CONDUIT 25,900 27,700 1,800 ' WIRE 6 CABLE 115,000 200,000 188,500 (200,000 '/tnit) S T f 4 a- -s-. -w-~ 9 m' ye .-g- ,,p4 y m- ---e e -g y 3

- - : ~ ~ ^ ~~ ' ^ ~ ~ -

--.-~ -.-

_r. / s YARD le All transfor=ers received, installed and ready for service ~ 2. Deluge system for Unit 2 transformer completed 3. Deluge system for Unit 1 transformer will begin in October of this year. - 4. 'Well drilling for permanent dewatering began on August 17 - two rigs working with third to be on site shortly

  • 5 5.

Pipe profiling - two runs complete - looks good - Southwestern Research Institute to be back on site September 16 and to finish by October 23 - Service water lines 19 & 20 next then 15, 16 and 53 & 54 will include condensate lines 6. UPS facility is being constructed - co=pletion due by October 1, 1981 7. Tech Support Center work started August 10 - Civil /Scructural to cocplete December 4. Arch, Mech &,Elec packages to be released in September, Novecher and March respectively. Total co=plete February 1, 1983. 8. Security fence rework - concrete around posts to begin shortly. Ductbank pulls are in progress 9. Cooling tower nearly complete, have some conduit plus pre-fab. control house yet to go 10. Boiler pr,oject - steel was received yesterday - schedule for comple' tion is February 1982 11. Borated Water Storage Tank - pre-load specifications released from NRC 12. Fond Blowdown structure - subcontract to be let in September and co=pletion scheduled for Ap,ril of 1982 13. Calibration Facility - concrete work complete superstructure scheduled for co=pletion-in November 1981. 6 J g } e ---=+e- +u a e.-wy* +-.-4 3 4+- 9 w y ,a ybe--y q 4+-thr-~ r ---r-r-'7P+ r--7 -'rTMd e e-'rwf -g--r'M--- N--- =-9-tw"P wu-r T --th+ -t~ r

au. m ywuu a 4 2 c2 y,,. g t;.g-._. ;t .. # @, .ij : Sij t F. vw... ) j

g. -

s }3 i. U I U'

f'.71.pfi l

i .m m m m g o MIX. g I g m j g ' S: I f m m m m m BUII, DING 8 ....i','. MODULE 3 1 j i 101 400 3000 265 246 l :. 102 /* C32 2860 127 464 8 l' : 103 554 2562 159 594 .4 110 I 1950 100 400 10 o ( s .t> 120 3100 418 2850 80 35 g 130 4640 450 2650 55 8 ,j. 140 3900 321 3000 12 90 ' ' i 150 9160 79 1060 9014 62 115 184 \\ f, \\. 160 705 35 432 2752 36 80 56 f

i 170 301 67 1584 64 394 116 CCW l

l l 175 178 1 2 hydro 8/31 to 9/11 i 180 1771 1600 49 1143 26 p 4 190 j 210 1513 15 134 796 7 22 220 5 109 0 l 230 545 9 i {, 240 865 283 12 7 52 i 250 820 357 371 2427 2 10 4 260 2736 34 110 695 20 19 43 i 31,an' ypit

  • ( c. D 36,3tl

'{lt 3 - 3\\Et

MIDLAND UNIT #1 AND #2 Total Plant Installation F.ates 1981 E=all Pipe- - Small Pipe liangers Conduit Wire and Cable January 8,556 410 10,339-85,738 - Februar-/ 6,392 560 20,00k 120,h39 March 7,127 h73 20,804 389,h22 April 8,660 768 18,676 738,380 May 8,133 329 1k,038 520 h55 June 5,77h 261 12,376 h58,801 July 7,269 506 15,591 662,238 Total 51,911 3,307 111,828 2,975,473 Av5 Per Month 7,h16 h72 15,975 h25,068 I ~ 4 f' s. -.

-...::::..==.. u:.

2...
r.... = ^

8 -2(a-2 I MIDLAND UNIT #1 rid #2 Total Plant Installation Rates i I 1981 Small Pipe Small Pipe Hangers Conduit Wire and Cable January 8,556 410 10,339 85,738 February 6,392 560 20,004 120.439-March 7,127 473 20,804 389,422 April 8,660 T68 18,676 738,380 May 8,133 329 1k,038 520,455 June 5,774 261 12,376 k S 8,80.'. July 7,269 506 - 15,591 662,238 - Total 51,911 3,307 111,828 2,975,473 Avg Per Month 7,416 472 15,975 h25,068 i i 1981 Large Pine Hangers Te minations J January. 208 1,947 Februr.ry 282 1,999 March. 234 2,806 April 256 5,831 May 221. 6,22k June 168 7,185 July 238 9,938 Total 1,607 35,930 Ayg Per Month 230 5,133 4 ~ee-. -~egs= -~+e w. e .o w .w,-o, a -+ o ~' seemg- +- -e 'm w a v.r*ry.=-..

.. - ~.. - - ~ OUANTITIES TO GO TOTAL FORECAST TURBINE 1 1) INSTRGEhTS 445 960

2) INST. TU3ING 14,781 30,171
3) LARGE BORE PIPE.

370 37,790 4) LARGE 30RE RANGERS 185 2,d20

5) SMALL BORE PIPE 3,900 41,200
6) SMALL BORE RRiGERS 300 1,427 7)

CONDUIT 7,000' 63,543

8) CABLE TRAY

+2,900 15,507 TURBINE 2 1) INSTRGIENTS t 71 960 2). INST. TUBING 8,649 31 892

3) LARGE BORE PIPE 140 42'400
4) LARGE BORE HANGERS 180 2'
5) SMALL BORE PIPE 2,000 46'488 l'507
6) SMALL BORE HANGERS 250
7) CONDUIT 6,000 72'273 195
8) CABLE TRAY

+ 800 14,'526 EVAPORATER BUILDING 1) INSTRGENIS 361 . 1,450

2) INST. 'FJBING 23,171 42,205
3) LARGE BORE PIPE 500 28,108 4)

LARGE BORE HANGERS 130 1,600 5) SMALL BORE PIPE 1,000

6) SMALL BORE HANGERS 84 40,683 2,169 7)

CONDUIT 1,000 53,430

8) CABLE TRAY

+600 DIESEL GENERATOR BUILDIN3 1) INSTRGENTS 58 58 2) INST. TUBING 1,610 1,610

3) LARGE BORE PIPE 1,000 2,770.
4) LARGE BORE HANGERS 74 120 5)

SMALL BORE PIPE 800 4,713 6). SMALL BCRE HANGERS 140 637 7) CONDUIT 500 oves scope 14,940 8) CABLE TRAY +185

j ~ ' r /r(gg i / g_g ia r - a - v /, 'Tr~: rii iTta !iF r rT t i l l l l l l l l l l l l l I i I I i i l l I i fr _,f,.,I l l l 1 I lI !l l !l l !II I i l l l l r l A_bl I I I I i l l I I I I I I.I I I Ii! l! I d uc.. ! I _$ M k2 3 I IM' l EN7 I !I I I i I' I i i R 0 L 7-ka;I-, li d _1 !I ! iC_O ! I On! ! /?f l !_7_O I! I I S 7 en al Ibl !.Jjo a! ! /J'o! l/ Un I i I l l i 7-/tr y, u b b I.!hdo i l I /_ 4

  1. d/A Bhd. I I /dob _

I I ! N# I I obol l /Eo! I $n l l I l I I I E / C.!tj /,t) n l II kI I l/do l[q3 ! !7) I !/0hn l l l l i e' [, l / l ll I-kifE I l l l c ^)'!r2. jd I f/j oa! I II i 8 'r' li - I' [j l /_Z43 f.l l 1 i' t e i l 1 i t i i i _?7'o:i l I j l l t i i 7 7eo i i i 11.l d I I !!?/[eFAl !d4M;l N1!!//I I 96,3 ! 3/29l I I i i l I l 1 l 4, & ri t a i 1 Co r t ! 5'OT/ f! ! //e ? 2 1 7E P! l I i I I I h J i/ t - i 1 J i i 'i i i e i l I I / 36.4.97 l ' /o. o '/ 7}- d, */ !7 fb 137 i /j !I 6 r i I i i IIIII liI l' l l l) l I I l l l Q fd, 6 i l l l l l l l l ll I I I I Il l I I I II l I I! l l I I I I II i i l Iil I i l I !l I 1 II I I I I i i bl k.d I i i l I II I I!I i l I l-l i i I i ~ l ei, L,.1, b) l I I I I I I W 6t! l I in M,i l I I i i i i l l I (i.ol,, ! I l I /pH 7 i 1 e i i i i l l r I i l l l l .iI i i i l ll 2, A I II l/[b,kl I 1 i I i l l I Il l !l l l l l l l i,4 I II i <! p!7 -d i I i !; 4 p i i l l u d.- L ! }.J,i - b p "I i1 z.!Pjul i I i ; vz_i i i i !/227 1! l ! ) vive i 4 M /v -, - I spju l I i /b. 44/ l I l I iw M i I l /! 7i7 4-l ! hir. k h I raj.fi i l l Uj d I I IiiiiI l.I I1! i: i &Aol.J l /50.!cd7 I i l i? i; b i I ! # h r leo!c i 4 5 =i/f e /b I b:1 1 I I uj n7!il i i i Su i2ir 6:559 /Ja2 f l 5 h 3I,.tyher:hA p'Qj ! it!/n = A l h-d d i l l le la' d u! l ee n !.tc h l ic; i I I b,!- J l l I i n '4 J 'i l I I i i i i i l l'T f ! I l l l I l 'l I l l I i Ij I I l I il i l l I i I I i l I I I I i I l i l I i l l I IJ l i I i il I i I I i iI i l! Ii l l i ! IiI i i I I l l l l l II I I i l l t I I I i i l i l i ll l l 1 I I i I I I I I i l I I l II I I I I I i II I Ii1 I I l l l l l l l lI I I I II l l I i i I l i I! i I II II I l l l I I i i l! I I Iii l !I l !!! II I l l l l l l l l I i l i i I l I Ii i l i i i l I !i! i I !l l l l i i !l I l 1 i i i l i li Ll .l i 1 i.ii l 1 I

i. :

i !1i i i

,a kd i IdJ b-L1 I rJ 9i s) i I I I Jl Ii Iii ~ l 1 hJ k S i l d i k i A l 4 a l.h I I Iil i Il' I 2 l Il i 1 I! IIIII l fII Il l l I I

d I

I rJnl LAJ l&19)% II I i1 l IIil l I I I i 12L I A/Lil icJ ti d del l i i lI I I i i li!I I I l' l i II l l l 1 I i i lll l I II L IP)> Ic h 1 4 41. 1 r) M i l I I_LI I I l1 I 1/A W M t W! kz! I i l Il I l l l l l l l IIIl l l !j i ! Ii! l Il l I I i i VJ.,L i i I d 4 W A J 17:I do n ! I i i !I i l I I i i i iiii lI I l / d b il 191 A Jz! ! I inlmL)! ii I i i b I Il l j i l i l l I I I i I l l l' l lI I Ii iii! l III II i !i l I I i i lIliI i Iil I! I 1 1II !I I I lIIII I I II II IiI i i I !I I I il i i l i II I I i l I II II I l l 1 I I i I I II I I! i l I I I Il! lII III lI i li i lIi; II I I I I I III i l II IilI i l i I l. l i i i l I I l l l t I !I I l I I I! lIIIi!II II l !I !I I I II I I I II II I I I IlI i i l I lI ll 1 I I I I I I I i lI I I! II II I II I i I I i i !i i I i i ilI I l l! i i i l i i I i i i i t i I l l l l l l l l I I I i-l I l' l I I I I l l l l l l I i l lI l !II I i i l I I I II i l i L ! I i i I i l I I I i lI! II II I Ii i I I I 1 i i l 'l I I l i i ll I I l l l il i i i l I i i l I I i l I i l 11 II I I II I I I I i li! I i l I i l I I I I I I i III I I I I 1 I I II I ii I I I I I I !II l l l I i l IIII !i I i I i ii! II I I I I I I I l!l! II I i i! I I II i i I i l l I II I I IIl l l !I I i i i i i t i i lI i II ll l l l l l l l 1 l l l l l l l l i ! Iii I I !l I !I I II I!l i l i I!IliI I I I !l t IiilI Il Il 'l l I !I I i !.I II I III!l i II Il I lII III I I i l i I I I i i l I Ii1 I I! II i lIi l !II !II I l l l l l l j i i lI i i i i li l Ii' I I Ii I i! I I i l iil I l l I II I I 1 I I I l !I II i i Ii l l I I I I l i i I!IIl l !I I i !I i l il l I l Ii! I i il l I II! l l l 1 1 i I I I'l l l I !I II I I I ~ lIiii l !I i i l i i l i i i i !Iil !I

l o j -p an tl'complenon.ca.tes 's l y

gN's r

By PAUL R AU cause the commission uscs that infot-tion ertnits for the two units. The per. sons, wn! p mit or unit 2 capires on Oct. I and for fitters will and LORIE SHANE , mation in deciding how much manpow-than 100 e. Daily News staff writer er to put into the Midland case. Hood unit 1. a year later. He said a decision on that should be craftsmen. Nuclear Regulatory Commission offs-explained.

  • Product cials this mornmg said they wit! st ek "There will be no charge in that pri-made by mid-September.

to their earlier prediction for the esti-ority for Midland." Hood said. He said Wednesday. a dozen Consumers and is "cempar mated date of completion of the Mid-the NRC still plans to issue its Safety Bechtel Power Corp. cificials gave age far nue Althout Evaluation Report and Draft Environ. status reports on various aspects of the L. land Nuctea.- Plant. i That mCJnb the Commisuon st'll De-mentJI Statement on the plant,by May Midland project such as m>ta!!ation two to nme first fuel 10 hcves construction on the plant's unit 2 1.1932. Hood called the.SER a " major rates. manpowcr and the procurement .h will be cumplete by October 1953, and milestone in the beensing efforts." situation for hardware yet to be in., not be dela J Officials on unit 1 by April 1934. Meanwhile. the The NRC is aiming to complete stalled. P'OM"* 5 ' Consumer Power Co. still maintains at SER's for 24 plants in the United Hood had hoped the cameload fore-the. N RC. n will compkre construction on unit 2 by States in 19!2. and for e,ght more in cast panel would be able to issue its projected f i i, July 1933. and on unit I by December 1933. Lovelace said. He and Hood said completion estimate Wednesday, but A Bechti it was impossible to say where the said after the session the NRC team sought in ' y 1953. P Both udes said this morning the Midland plant ranked on that list. be-needed Wednesday night to " digest" conect sa-E- three. and four. month differerices in cause schedules and estima'ted dates of all the information preanted by Con-buildings. completion at various plants change sumers and Bechtel. the servict f.; projection are not major, from year to year. H d og Lovelace did say that in some other IN THE!R reports, cff.cials from the dI"8 P' CC 4 .) THE NRC decision was made by a cases the NRC's projection is as much two companics said; panel of NRC otheials who heard re. ports and toured the plant site Tuesday us two years different than the owner's

  • The nuclear plant is now 71 percent the NRC w C

and Wednesday. They are Darl Hood, projection, Complete, compared to 62 percent at tive work Hood said that in making their pre. this time last year. In mid-f project manager of the Midland plant; diction, reports on the plant were "fac-rty per >N Wilham Lovelace, who issues all fore-tored into a generic base" and com-g; ,, energ z. or onn te the remes F casts for all U.S. nuclear plants; Eli. nor G. Adensam. acting chief of NRC pared with other plants of similar power, and 60, percent sh)uld be ener-sumerg to {A L' heenung branch s4 and Ronald Her-deugn. The rate of installation is corn-t . la t anpo , now at 4.117 per-i$n2 giz b Q nan, a project manager hke Hood, but pared to the amc.nt of work remain-mg he said. Lovelace admitted after 5. for other nuclear plants. the session he had doubts about the ih "The way it comes out is that on the jN baus of the information you've provid. " electrical area" of the plant price to the evaluation. p ed us, barring unforeseen ctrcum- . stances. we see no reason why the He said, however, the reports show Consumers work is "well above indus. schedules that we projected at our trial efforts." in that area. 'y) cascioad visit of last year should not rs Lovelace told Consumers officials ?-( be met." Hood anounced. e t He said the October and Aptil dates "you can't refute what you've done t..f are " reaffirmed by 'the new cval. over the last seven months." .Q' uation." WEDNESDAY REPORTS included a Ah CONSUMERS OFFICIALS said they presentation by Robert Wheeler, of, Consumers. on hulk installation rates were pleased with the announcement Wheeler pointed out that Ccnsumers* 3 J - 'J and said they beheve their projection had promised it would " pull" five mil- ,y and the NRC's are "essentiany in lion icct cf cable by mid 1991 and that 9 a greement." currently employees have topped the, N "We're pleased they have reaffirmed six miUian pomt. Pulhng cabic

  • their concluuon.* Consumers vice me,ans placmg it in conduit trays.

. preudent of projects, engmeering and 4* construction Jamc3 Cook said after the by 1.3 milhon feet.,our estimate to you We've exceeded b Wheeler said. brief sesuon today. Cook said he be-g[ hesed the 1930 reorganization of tcp-l lesel personnel could be termed a ma. IN A separate area. Cook charged - E1 Jor factor m the company *> abihty to that a statement by state Attorney General Fra*:k Kelley that there is no i~ mamtain its schedule. "It's an expression of the commit. proof the Midland nuclear plant is ment of Consumers Power Co. to get needed in " baloney." _..g this job done in the most expeditious Kelley filed a suit Monday asking the y'.' manner." he said. state CDun t1 ApptaMb s'topTnc com-q ~~ M M4 d; "It helps our morale tremendously." pany from sc!hng $363 milhon in stocks di' y %,' ? + Don Miller plant site manager, said of and bonds to pay for the plants. i ~, KcIley also claims the company's i the prediction. customers would be forced to pay mi!-~ 3 , sumers' "abihty to keep up with the lions of dollars in interest and divi-WW $3 ' 'q He said the decision shows Con-W dends if the' stocks and bonds vicre 4 schedule " sold. .t DESPITE the difference in Con. "Mr. Kelley's primary purpose ap-sumers project manaper projections, pears to be to make Michigan a de- %g Gilbert Keeley said "I thmk eserybody pressed area for as long as he can

  1. ~ pp g is tarpeted for our July 1983. date. acd keep it that way." Cook said.

5-t. we will contmue to target the dste.' in another area. Hood said he sees N, The NRC crotection is important be-no probiem with extendmg construc-t Se ,G ~~ h DI ?

{

orrioletion dates stand

~ M /fM use the commission uses that infor. tion permits for the t wo units. The per. Sons, wiil peak in 1992. About,50 pipe. ation in deciding how much manpow. mit for unit 2 expires on Oct. I and for fitters will be added along with more to put into the Mid.and case. Hood unit 1. a > car later, tha n 100 electricians and about 130 plamed. He said a decision on that should be craftsmen.

    • There will be no charge in that pri.

made by mid. September.

  • Productivity among these workers sty for Midland." Hood said. He said Wednesday, a deren Consumers and is "comparab!c with the national aver.

c NRC still plans to assue its Safety Bechtel Power Corp. officials gave age for nuclear construction." ialuation Report and Draft Environ. status reports on various aspects of the + Although work in some areas is ent.at Statement on the plant by May Midland project such as installation two to nine months behind scheute, the 1992 Hood called the SER a " major rates manpower and the procurement first fuel load date in June 1933 should ilestor.e in the licensing efforts." situation for hardware yet to be in., not be delayed. The NRC is aiming to complete stalled. Officials also said the plant's soil

R's for 24 plants m the United Hoo' had hoped the caseload fore, problems while not yet resolved with d

ates in 1992, and for eight more in cast panel would be able to issue its the. NRC, also should not delay the

13. Lovelace $sid. He and Hood said was impossible to say where the completion estimate Wednesday. but projected fuel load dates.

diand plant ranked on that list, be* said after the session the NRC team A Bechtel official said bids will be use schedules and estimated dates of needed Wednesday night to " digest" sought in the near future for work to mpletion at various plants change all the information presented by Con, correct soil problems underneath two sumers and Bechtel, buildings, the auxiliary building and em year to year. i the se/vice water antake structure. '.ovelace did say that in some other IN THEIR reports, officials from the Hood agreed that the fact that bid. ses the NRC's projection is as much two companics said: ding proccas is beginning reflects con-two years different than the owner's t E'" I + The nuc! car P ant is now 71 Farcent Jection. -food said that in making their pre. complete, comoared to 62 percent at the NRC will permit the type of correc. live work that is being bid out.

tion, report > on the plant were "fac.

this time last year. ed into a generic base" and com.

  • Forty percent of plane electrical In mid October, a federal hearing red with other plants of similar ci cuits are energized. or connected to will resume on the appropriateness of the remedial work proposed b sumerg to fix the soil problems,y Con.

nign. The rate of installation is com. power, and 60 percent should be ener* which red to the amount of work remain. gized by year s end-have caused cracked and sinking

. he said. Lovelace admitted after
  • Plant manpower, now at 4.117 per, build.ngs at the plant.

? session he had deubts about the lectrical area" of the plant prior to . cvaluation. ic said, however, the reports show nsumers work is "well above indus. Al efforts." in that area. .ovelace told Consumers officials ou can't refute what you've done

r the last seven months."

VEDNESDAY REPORTS included a tsentation by Robert Wheeler, of, numers, on bulk installation rates. Wheeler pointed out that Consumers - 1 promised it would." pull" hve mil. 1 feet of cable by mid.1981 and that rently employees have topped the million point. " Pulling cabic" ans pl. acing it in conduit trays. We've execeded our estimate to you 1.3 milhon Icet." Wheeler said. 4 A separate area. Cook' charged t a statement by state Attorney teral Frank Kelley that there is no of the Midland nuclear plant is ded in " baloney." clicy hied a suit Monday asking the .e Court b1 Apptiisib stopTne com. y from sciling $363 milhon in stocks l (11cy also claims the company's.

  • k,. y. pmM/ '

3-Q g Jf".WJ<.;-g "['i $ $. %g bonds to pay for the plants. jl@'fU, ', Q Q M Ae ,t *g y. g i D.. ST,DP Qh% t',Qf J - r I tomers would be forced to pay mil. . y gj

.9 g*=,{

.~ y . g C ra ~ h y, j j. s cf dollars in interest and divi. o g.. f..mp.g . phi 1 n iN 74 d.epQ(@Af,m $ p.S M tis if the stocks and bonds were

. f..j W ;. 4 1 (;,i. s..(

At.. m ~ f. 4 ,f 5fr. Kelley's primary purpose ap-o -r .. '.,.,.j L g rs to be to make Michigan a de. ,'p {i . ' f ;s \\. "p fLV f* C '^' w, hy'M . sed area for as long' as he can N 1 ~ .t c. .// ) it that way." Cook said. 4r8 1 another area. Hood said he sees ',tDL 3roblem with extendmg construe. f 3, ' g '; p.",; y T 7'. ., ' ) T @.+(w7 1 e ,.,-em..

  • a-s.8-

[. j t d x, _.,., +., ~,,., - e

' Ofncials said that powder like particles. called " fines." get back mto the water temg procemed allowmg radioactvity to remam there :sstead of being transferred mto manageable n tesm beds. l3..;a !af:$i!ce.~c:, Jac. The parteles were described as m ex...:.. ,:.c. eee, be:ng as small as one ten-thousandth of an inch. Bedell md there was no fll,' (;',

g. l danger the parueles could escape mto the environment.

..-u--.. , -, l, ' " ' " * * ^ * ; Eng:ceers have been tesung the . i..."~. A, ;j'*, *; *e system smee July on 90,000 gallons of g p less radioacuve water in boldmg s *** tants at the plant

..f '.. - - - - *05 T"0 A 7 -- 10 5,' 4 25 ne Insutute for Safe Technology.

m today's announcement calls for 494 GPU to y decontammate the + water. it m a special plaste beder or concreu, then ship it off g %as -d-d the t,e><- Consumers N-plant ed water on site until a final decisioe -c on -s l esmaver,o.aecha at Midland on schedule e workers - oce fatal cancer and one genece mutato's - is far toc low. TM seeth News Service msttute. say.ng :t has found errorse resources necessary to meet those the NRC calculations. esumates twe WDLAND - The Nuclear dates," he said, adding that the to 10 TMI workers may d:e of cance Regulatory Commission and Con Midland plant's relative position as a result of the cleanup. sumers Power Co. remain in "es" in the race for operating licenses j will remain unchanged. N j sential agreement" that construc-Hood said Midland is "one of tion on the nrm's $3.1 billion nu* the NRC's top priorities, although clea energy plant is on schedule, not necessarily the top one." The agreement, announced bY Panel member William Love-tSe NRC caseload forecast panel, lace said the NRC 9111 consider 24 means Consumers will remain high on the agency's priority list operating license applications in 1982, with eight cases scheduled - of operating license applicants, for 1983. according to Darl S. Hood. NRC 1.ovelace concedes he had project manager for the Midland plant. doubts Consumers could remain on its construction schedule, but , The decision came despite a four month difference in the est1* said "you can't argue with the naeted completion date of the progress made over the last seven { months." phat The panel estimates the Evidence presented by Con-completion date of Unit 2 as Octo sumers shows the plant is now *1 t i 1983 and Unit I as April 1984; per cent complete, up 9 per cect ers says it still is commit

  • from June 1980.

l to a July 1983 date for laaettne r$!!oective feel pellets, with com,,, pattion of Unit I scheduled in De-c&nber 1983. '2 Hood termed the differences Dignificant," and Consumers reaffirmed its commitment to meet the July 1983 date. "On the basis of the informa-tion provided, and barring any un-forseen problems, we see no res-son why the schedule projected at the last caseload panel meeting cannot be met," Hood said. "We will continue to apply the 03 A ~ - - ~ ~ ~ - - ' ~

y?l 5 C 4...,. :. .-; ;.,i i i 1 5 1 7 S (10/1/81 T9Fi' 9/30/83) ?.coresED 5:sE.nu I 7.1.*. lAMi N 1'.3331 fo; FY_S3

  • l.

fdia.qqq 9/81 11/15/82 Vis1TED ~2. iMiEt 3c 2/79 11/30/82 Visirso o3. PETj3 10/81 1/10/83 VIsITen .i 4.4. EEI.vEDINlisiBJ 1/25/83 VisiTen .,' 5. .Hu. n. 3 2/16/83 VisIreo gT?'fiifflhifm&2 2/22/83 VIsiTeo i o, o. I s 7. NKTtQq. 12/80 3/1/83 Vis!TED y E 8. '43. SA!Istg/3WA3 3/22/83 v:i1,ren ..- ~ acules ' ' 1. r c. o Rn. -., 03 3/81 3/28/83 Scsa cutze o 9. .=n.gt t' ,10.,y,q.G.FM$3 4/4/83 S a.>irco r; gr mun lell. @ jl[5d 8/79 4/11/83 [$[:$f-en !12.Qilg 8/81 4/18/83dId$Nb _s-q.. p. G,._AT.EAF.,QR,Dj 1/81 4 03 3CHEDULED N.5br%[d f 14 q.?j d L5 h,/ 3/82 5 7l & y.v 3 g rM'. r rp' 1 s h. Go~wh 5 f 015. (qm yrm g ' 9.-W e y y 17. COMANCHE PEAK 4/82 5/83

18. d5%El #

11/81 6/?F V/5NE.c 19. CLINTON ' 11/80 5/03 ?/d J 20. idis h d 10/81 E/??- 7/w//.? 21. BELLEFONTE-9/81 7/83 [ 22. CATAWBA [ 8/81 7/83 23. BRAIDWOOD 1/81 8/83 ~ > 24. (. M ii.T3 8/82 3/23-IhS/rI4 25. S0urs TEXAS 4/78 8/83 i _2_6. WNP 3 8/82 9/83 27. MILLSTONE 3 9/82 9/83 b 28. CALLAWAY / 9/82 9/83 ,8.3p}}