I  !

-t e TOL EDO EDISON

, A Centerior Energy Company EDO OH 1 December 13, 1994 Ohio Environmental Protection Agency Division of Surface Vater CH&E - Permit Compliance Unit 1800 Vatermark Drive P.O. Box 1049 Columbus, Ohio 43215 Ladies and Gentlemen:

Subj ect : Submittal of the November 1994 Vastewater Report Attached is the November 1994 Vastevater Report for the Davis-Besse Nuclear Power Station (DBNPS), Unit Number 1, Permit Number 2IB00011*ED.

If you have any questions, please contact Mr. Villiam T. O'Connor, Manager -

Regulatory Affairs, at (419) 249-2366.

Very truly yours, b 42.-

John K. Vood Plant Manager Davis-Besse Nuclear Power Station TKV/1kg Attachments cc: Z. A. Clayton, Ohio Environmental Protection Agency U. S. Nuclear Regulatory Commission Document. Control Desk l

0 9412220226 941130 PDR ADOCK 05000346

,)I '

R PDR v n

1

.6 4500 a40NTHLY REPORT FORM w ,

70 LID 0191801 C0ttHT 21800011001 107 1994 1 1 12/17/93 080003786 Mill 8188I HCLi&t P0 fit Ifif!01 - 8HIf 10. 1 300 IH!l01 H. R$f0F 2101 001 DISCHIGI f0 LHI IIII f0 LID 0 43652 Off1 8 FORM 70 Lit 0 IDISOI J.Stardavant 1 3 1 3 999 1 999 1 Mfit FI COIDOI Citot flip. FLOI ftII A F 8.U. IGD RG/L

0011 00400 50050 50064 01 53.3 8.3 21.3 H 02 51.0 8.2 25.3 1A 03 49.8 8.2 33.4 H 04 51.0 8.0 49.4 H 05 52.0 8.1 46.1 M 06 52.6 7.8 49.8 H 07 51.2 8.1 47.8 H 08 50.5 8.1 45.7 H 09 50.3 8.2 53.3 H 10 49.7 8.2 51.0 H 11 49.7 8.3 57.1 H 12 49.3 8.1 47.7 H 13 49.8 8.0 39.1 H 14 51.0 8.0 39.3 H 15 52.4 8.0 39.1 H 16 53.7 8.2 36.1 M 17 54.7 8.4 27.3 H 18 56.8 8.5 27.1 11 19 53.5 8.5 33.5 H 20 54.6 8.6 30.1 H 21 52.5 8.7 29.0 H 22 53.6 8.7 30.4 H 23 50.9 8.7 29.8 8 24 49.2 8.7 33.7 H 23 49.7 8.8 30.1 H 26 48.9 8.8 28.0 11 27 50.3 8.8 26.9 H 28 51.6 8.8 28,9 H 29 48.8 8.7 28.3 H 30 49.4 8.7 35.4 H 31 l 1541.8 ---

1100.0 0.0 51.0 ---

37.0 0.0 56.8 8.8 57.1 0.0 48.8 7.8 21.3 0.0 l

! W The free stallable chlorint ittectica limit is 0.05 agiL asing the direct aspercantric sethod.

unman 2IB00011001 g /kt3 9Y k Plant Manager

4500 spNTHLY REPORT FORM f0LIDOIDISOIC0tP11f 21800011002 IST 1994 1 1 12/11/93 010003786 DATII II!!I 11C1111 FCIIIITAf!0I-Vilf10.1 300 X1 DIS 01.AT. ESTOP 2101 002 00fl1LL 700!$113f IITIl 70 LID 0 43652 Offall FORM 70 LID 0 IDIS01 J.Stordavant 3 3 3 1 1 1 1 199 FI II5!DO 0&G COIDDI

f. IIL 70f1L ILOI 3.0. EG\L EG/L EGD 00400 OGi30 00550 50050 01 0.158 02 3.8 0.068 03 1.7 0.068 04 0.158 03 0.284 06 0.104 07 0.068 08 0.188 09 8.0 4.7 0.518 10 1.2 0.068 11 0.068 12 0.068 13 0.068 14 0.068 15 7.9 0.074 16 5.1 0.068 17 11 0.068 18 0.068 19 0.068 20 0.068 at 0.074 22 8.1 0.068 23 11.1 0,068 24 11 0.068 25 0.068 26 0.068 27 0.224 28 0.158 29 0.068 1

30 0.068 31 24.7 2.9 3.300 5.3 0.7 0.100 8.1 11.1 1.7 0.518 7.9 3.8 1.2 0.068 11: The 011 and Grease detection limit is 1.0 agIL using tbt partition grafisttric attbod.

m oa 2IB00011002

/L-(3 9V d h Plant Manager

o 4500 M*fmLY REPORT PORM 70 LID 0 191801 C0EF&If 21800011003 10f 1994 1 1 12/17/93 050003786 D&fl8 BI88I IICLIAI P0 fit 8f&f!01 - IIff 10,1 300I&DIl0167.E870F2101 003 OfffnLL Inf&III I&III f0 LIDO 43652 OffAIL 70 LID 0131801 J. Stardanat 3 1 1  !$9 188100 COIDII

f. IFL FLOI IGIL IGD 00530 50050 01 0.222 02 15.5 0.222 03 0.222 04 0.222 05 0.222 06 0.222 07 0.222 08 0.222 09 0.222 to 0.222 11 0.222 12 0.222 13 0.222 10 0.222 10 0.222 16 0.222 17 0.222 18 0.222 19 0.222 20 0.222 at 0.222 22 0.222 83 0.222 24 0.222 25 0.222 23 0.222 27 0.222 28 0.222 29 0.222 30 0.222 31 15.5 6.660 15.5 0.222 15.5 0.222 15.5 0.222 mmmun 2IB00011003

/ 2 -p - Q V Q(y3 d Plant Manager  !

f

/

4500 spurHLv nepont ronu f0 LID 0 50!$03 C0Ellif 21I00011601 10T 1994 1 1 12/17/93 010003786 DAf!8 II!!I IUCLIll 70f!I SfAfl01 II!? 10. 1 300 RADI$0i AY. Elf 07 2101 601 DISCIIIGI $ff 70 LID 0 43652 OffAI&

FORM f0 LID 0 IDIS01 J.Sturdatant 3 3 3 1 3 3 1 1 1 999 1 1 COLOR ODOR f31 BID COIDUI BOD RISIDI SITII SITII SITIR FLOV 5 DAT f. IFL Ullf8 Ullf5 Illf8 EGD EGIL EGlL 00083 01330 01350 5005G 00310 00530 01 1 1 1 0.027 8 02 1 1 1 0.029 21.6 03 1 1 1 0.029 04 1 0 1 0.028 03 11 11 13 0.027 06 11 11 13 0.027 07 1 0 2 0.027 08 1 0 1 0.028 11 09 0 0 1 0.035 5.6 to 0 0 2 0.024 11 1 0 1 0.014 12 Al Al 11 0.029 13 11 13 11 0.026 14 1 0 1 0.026 12.7 15 1 0 1 0.022 6 16 1 0 1 0.022 17 1 0 1 0.018 18 1 0 1 0.010 19 13 II 11 0.033 20 AI AI II 0.033 21 1 0 1 0.033 5 22 1 0 1 0.024 11.2 23 1 0 1 0.012 24 1 0 1 0.011 25 1 0 1 0.011 26 Al 11 11 0.018 27 al II 11 0.018 28 0 0 .1 0.018 29 0 0 0 0.021 6 30 0 0 1 0.022 11.8 31 17 3 23 0.702 25 62.9 1 0 1 0.027 5 12.4 1 1 2 0.035 8 21.6 0 0 0 0.010 5 5.6 AA: The BOD dettetion limit is 4.0 ag/L using the altetrode nethod.

2IB00011601

/ Z. * /3 - 98/ ( d Plant Manager

4500 ejoNTHLY REPOST FORM f0 LID 0 IDIS03 C0Xfilf 21800011602 10f 1934 1 1 12/17/93 0I0003786 Dif!8 ill3I IUCLIII POIII$fif!0I-Vilf30.1 300 RAD!l01.1T. R$f0F !!01 602 L0f TOLUXI II SiffLIIG 81311 Of!!!LOI f0 LIDO 43652 Off1Il FORM 70 LID 0IIIs01 J. 8turdavant 1 3 3 COIDO 1851DU OGG FLOI f. IfL f0f1L EGO EGIL RGIL 50050 00530 00550 01 0.282 02 0.282 8.2 03 0.282 2.1 04 0.282 05 0.282 06 0.282 07 0.282 08 0.282 09 0.282 to 0.282 11 0.282 12 0.282 13 0.282 14 0.282 15 0.282 16 0.282 5.4 17 Q,182 2,4 18 0.282 10 0.282 20 0.282 21 0.282 22 0.282 23 0.282 24 0.282 25 0.282 23 0.282 27 0.282 28 0.282 29 0.282 30 0.282 31 8.460 13.7 4.5 0.282 6.8 2.3 0.282 8.2 2.4 0.282 5.4 2.1 noonna 2IB00011602 1713 98/ d Plant Manager

,g

EpNTHLY REPORT FORM 70 LID 0 IDIS0I CORP &If 21800011801 30f 1994 1 1 12/17/93 050003786 D4f15 3888B IICLlit P0 fit IfAfl01 - Illf 50. 1 300XADIS0I47.R$f0F2101 801 IIfAII ft10t C00LIIG Ottilf!01 701100 43652 Offiti FORM f0 LID 0 801801 J. Stordavant 1

199 Infit flip.

1 00011 01 51.9 02 50.3 03 49.5 04 50.6 05 51.8 06 52.6 07 49.9 08 50.6 09 49.3 10 48.7 11 48.4 12 48.6 13 47.8 14 48.6 15 49.6 16 49.6 17 51.8 18 52.7 19 49.5 20 48.9 ai 57.6 22 50.1 83 46.6 24 44.1 23 42.9 a6 43.8 37 43.2 28 44.3 29 43.0 30 41.8 31 1458.1 49.0 57.6 41.8 mmann 2IB00011801

/E-g J .4 / Plant Manager  ;