e TOLEDO EDISON A Centenor Energy Company EDISON PLAZA 300 MADISON AVE NUE TOLEDO, OHto 43652-0001 i

December 11, 1995 Ohio Environmental Protection Agency Division of Surface Water CM&E - Permit Compliance Unit 1800 Watermark Drive P.O. Box 1049 r

Columbus, Ohio 43215 Ladies and Gentlemen:

Subject:

Submittal of the November 1995 Wastewater Report Attached is the November 1995 Wastewater Report for the Davis-Besse Nuclear Power Station (DBNPS), Unit Number 1, Permit Number 2IB00011*ED.

t i

If you have any questions, please contact Mr. Peter W. Smith, Manager -

Regulatory Affairs (A), at (419) 321-7744.

.Very truly yours, Join K. Wood Plant Manager Davis-Besse ;uclear Power Station TKW/lkg Attachments cc:

Z. A. Clayton, Ohio Environmental Protection Agency

.U2 S.-Nuclear > Regulatory Commission. Document-' Control-Desk 3.

I y ~ r,,_

00

- U L t. (h (g

~ 9512180214 951130 PDR ADOCK 05000346 R

PDR

l 4500-OmLY RE T FORM 70 LID 0 ID1805 C0KinIf-21800011601 10f 1995 1

1 12/06/95 080003186 Dif1S BISSE 10CLInt f0 tit $fifl0E - IIIT 10. 1 300 R& DIS 0517. ISf0f 2101 601 DISCI 1RGE Sff 70 LID 0 43652 Off451 FonM f0 LID 0 5D1801

f. I&SCB 3

3 3

1 3

3 1

1 1

999 1

1 COLOR ODOR TIRBID C0lD11 10D

!!SID0 SITIt SITER SETIE FLOI 5 D&T

f. IfL OllfS OllfS BllfS IGD NG/L HGIL 00083 01330 01350 50050 00310 00530 01 1

0 2

0.021 9.3 02 1

0 2

0.021 03 1

0 2

0.012 04 11 al 11 0.022 05 15 11 11 0.022 06 1

0 1

0.022 07 1

0 1

0.016 6

08 1

0 2

0.019 12.6 09 1-0 2

0.016 10 1

0 2

0.014 11

&E

&R 13 0.001 12 11 11 1R 0.001 13 1

0 2

0.022 14 1

0 1

0.022 4

15 1

0 1

0.018 12.8 16 1

0 1

0.015 17 1

0 1

0.011 18 11 11 11 0.010 19 15 11 11 0.010 20 1

0 2

0.010 21 1

0 2

0.013 8.4 22 1

0 2

0.014 23 1

0 1

0.018 24 1

0 1

0.016 25 11 11 11 0.012 26 15 11 15 0.012 27 1

0 1

0.012 28 1

0 1

0.010 4

1 29 1

0 1

0.014 5.2 l

30 1

0 2

0.009 31 22.000 0.0000 33.000 0.4410 14.000 48.300 1.0000 0.0000 0.6661 0.0190 3.9000 9.9000 l

1.0000 0.0000 2.0000 0.0220 6.0000 12.800 1.0000 0.0000 1.0000 0.0010 4.0000 5.2000 AB: The BOD detection limit is 4.0 ag/L using the electrode atthod.

AtPORTER

'd'4* 84 6 *** esesu see, ee e ese

/

2IB00011601 12/11/95 MC)nfe 1

Plant Manaeer O!I!llllllill3l}llIUl

c o r,-

4500

$1THLY REPORT FORM 70 LID 0 DIS 01 CORP &RT 21500011602 10Y 1995 1

1 12/06/95 010003786 M ilS IBSSI.IOCLEnt 7051t Stifl0E - II!! 10. 1 300 EDIS01 AT. Elf 07 2101 602 LOR V0Litt II SIffLIIG B&SII OVitfL05 70 LIDO 43652 Offkll FORM TOLID0 IDIS05

f. InSCB 1

3 3

999 1

1 CORDI RESIDO 06G FLOI

f. IIL 70faL NO MGIL RC '1 I

50050 00530 00550 t

01 0.460 1.0 02 0.460 03 0.460 04 0.460 05 0.460 06 0.460 07 0.460 08 0.460 09 0.460 10 0.460 11 0.460 12 0.460 13 0.460 14 0.460 15 0.460 1.6 16 0.460 17 0.460 18 0.460 i

19 -

0.460

, 20 0.460 21 0.460 j

22 0.460 23 0.460 24 0.460 25 0.460 20 0.460 27 0.460 28 0.460 29 0.460 l

30 0.460 l 31 13.800 2.6000 0.0000 1

0.4600 1.3000 0.0000 0.4600 1.6000 0.0000 0.4600 1.3000 0.0000

&&i The Oil and Grease detection limit is 1.0 sg/L neing the partition-gravinetric nethod.

l REPORTER sea ass 4 64

  • em M*Me see #48e N4' 21B00011602 12/11/95 m hsk IlllillllIllllllllll!l[

P1 ant Mannner l

4500 ONTNLY REPORT FORM f0 LIDO IDIS01 Colfalf 21900011801 HV 1995 1

1 12/06/95 0I0003186 D& TIS BISSI IICLlat POUR Sfifl01 - II!! 10. 1 300 51D1801 17. R$f0F 2101 801 IIfitt PRIOR C00LIIG OFItifl01 70 LIDO 63652 OffAI&

FORM 70 LIDO IDIS01

f. IASCI 1

999-Infit

7857, t

00011 c1 49.3

.02 50.4 03 51.0 04 47.2 os 44.1 06 43.2-07 43.6 08 42.6 09 40.8 10.

39.9 11 41.2 12 40.2 13 38.8 14-38.1 15 38.1 16 36.4 17 36,8 18 38.8 19 39.4 20 40.3 21 41.2 22 44.6 23 40.0 24 39.3 25 39.8 26 46.4 27 46.4 28 46.4 29 39.4 30 40.4 31 1265.3 42.177 51.000 36.400 acronnn

'** *i sa = a e === in 2IB00011801 1 ? /11/o s de Illllllllll!llilllllUllI ninne u o,,,,,

4500 ONTHLY REPORT FORM f0 LIDO IDIS05 COEPAI!

21800011001 107 1995 1

1 12/06/95 0B0003186 D1715-95535 IOCLIkt j

70538 Stifl01 - IIIT 50. 1 300 R& DIS 05 AV. ESTOP 2101 001 DISCB&tGB f0 Litt IIII f0 LID 0 43652 OffAIA FORM 70LIDOIDIS01

f. I& SCI

{

1

~3 1

3 999 1

999 1

j Infit fB CORDUI CILOR flRP.

fL05 FRIE &

)

3.1.

MGD RGIL l

00011' 00400 50050 50064 01 51.6 8.6 26.1 la 02 60.0 8.1 26.2 1h 03 54.1 8.1 32.6 04 51.0 8.6 26.3 05 48.1 8.5 26.3 06 49.2 8.5 26.3 11 07 51.1 8.6 26.3 ha l 08 48.5 8.6 26.3 11 09 46.5 8.6 26.3 10 48.8 8.1 30.8 l

11 50.0 8.8 30.6 12 46.2 8.6 26.4 13 46.3 8.1 26.4 hh i

14 45.8 8.1 26.4 i

15 46.1 8.1 26.3 Ah j

16 44.4 8.1 26.2 lh 17 44.4 8.1 25.8 Al 18 46.1 8.6 25.6 AA I

19 46.4 8.6 21.9 11 20 49.1 8.1 26.5 11 21 48.0 8.1 26.0 la l

'22 50.0 8.6 26.0 th 23 46.8 8.6 25.9 11 24 44.9 8.6 25.8 11 25 41.1 8.6 25.8 AA 26 53.6 8.6 25.8 11 27 53.6 8.8 25.1 28 50.0 B.8 25.1 Ak i 29 46.4 8.8 25.1 1A

! 30 41.5 8.1 25.9 in 31 s

1468.8 199.90 0.0000 48.960 26.663 0.0000 60.000 8.8000 32.600 0.0000 44.400 8.5000 25.600 0.0000 11: The free available chlorine detection limit is 0.05 ag/L using the direct asperosetric method.

noonna

.a.4.....,

21B00011001 m l/hb

/

Plant Ma n a p +.r Illllllll1NllllllllIl 1 ? /i1/os

4500

)NTHLY REPORT FOR:J 70 LID 0 IDIS01 COMPAII 21B00011002 10V 1995 1

1 12/06/95 0E0003186 D&f15 BISSI IUCLI&R POIIR StafI05 - DIlf 30. 1 300 R& DIS 01 AT. RSf0f 2101 002 00ff&LL 700SSkIIf RIVII f0 LID 0 43652 OffnIA FORM 70 LID 0 E01801

f. I&SCE 3

3 3

1 1

~1 1

999 fB RESIDU 06G COIDUI

f. IFL 70f1L FL05 S.U.

RG\\L NGIL EGD 00400 00530 00550 50050 01 Al AH LH AH 02 kB 03 AH 04

&H os 1H 06

&H kH kH AB.

07 AH 08 AH 09 AH 10 AH 11

&H 12 AB i

13 AH 1H 1H AH 14 AH 15 EH 16 AH 17 AH 18 AH 19 1H 20 AH AH AH AB 21 AH 22 LH 23 LH 24 AH 25 AB 26 kB 27

&H AH 1H AB 28 kH 29 LH 30 LH 31 AH AH 0.0000 aH LH 0.0000 AH kB LH 0.0000 AH AH LH 0.0000 18: Io flovi the discharge gate was closed throughout lovember 1995.

l I

2IB00011002 12/11/95 M

Plant Manaeer !!lll!!llllIU!N!!!}k

4500

ONTHLY'itEPORT FORM 70 LID 0 IDIS01 CORP &If 21B00011003 10V 1995 1

1 12/06/95 080003786 l

D& TIS-BISSI 10 CLEAR 1

POIIISTA'IOR-Ollf10,1 I

300 NADIS01 17. ISf0F 2101 003 00f!!LL IATARRE R&RSH f0 LIDO 43652 OffAIA FORM 70 LID 0191801 f.IASCE 3

1 1

$$9 1881D0 C0IDII I

f. IFL FLOI IGIL NGD 00530 50050

)

' 01 18.4 0.222 02 0.222 03 0.222 04 0.222 05 0.222 06 0.222 07 0.222 08 0.222 09 0.222 to 0.222 11 0.222 12 0.222 13 0.222 14 0.222 15 0.222 16 0.222 17 0.222 18 0.222 19 0.222 20 0.222 j

21 0.222 j

22 0.222 23 0.222 24 0.222 25 0.222 26 0.222 27 0.222 28 0.222 29 0.222 j

.30 0.222 31 18.4000 6.6600 18.4000 0.2220 18.4000 0.2220

[

18.4000 0.2220 i

t i

/

2IB00011003 12/11/95 M

d Plant Manager ll)flNl)lMl[lll