  • TABLE 3.3.5.3-1 POST-ACCIDENT MONITORING INSTRUMENTATION MINIMUM NO.

OF OPERABLE m.,

INSTRGHENT 8

INSTRUMENT AND INSTRUMENT NUMBER

_ CHANNEL 5 1.

Reactor Vessel Pressure 2

(B21-PT.-R004A,B; C32-LPR-R608; and C32-PT-N005A,B) 2.

Reactor Vessel Water Level -

2 (B21-LITS-N026A,B; B21-LR-R615; B21-LI-R604A,B; B21-LT-NO37; and B21-LT:(-NO37-1) 3.

Suppression Chamber Water Level 2

(CAC-LT-2601; CAC-LI-2601-1)

(CAC-LT-2602; CAC-LR-2602) 4.

Suppression Chamber Water Temperature 2

(CAC-TR-1258-14, 21; and C91-P602) 5.

Suppression Chamber Atmosphe're Temperature 2

(CAC-TR-1258-17 thru 20; and C91-P602) 6.

Drywell Pressure 2

(CAC-PI-4176; CAC-PT-4176; CAO-PR-1257-1; and CAC-PT-4175) 7.

Drywell Temperature 2

(CAC-TR-1258-1 thru 13, 22, 23, 24; and C91-P602) x 8.

Drywell Radiation 2

(CAC-AR-1260; CAC-AQll-1260-1, 2, 3; CAC-AR-1261; CAC-AQH-1261-1, 2, 3; CAC-AR-1262; and CAC-AQll-1262-1, 2, 3) 9.

Drywell Oxygen 2

(CAC-AT-1259-2; CAC-AR-1259; CAC-AT-1263-2; and CAC-AR-1263) 10.

Drywell Hydrogen 2

(CAC-AT-1259-1; CAC-AR-1259; CAC-AT-1263-1; and CAC-AR-1263) 11.

Safety Relief Valve Position Indication:

1/ valve

~

a.

Primary - Sonic (B21-FY-4157 thru 4167) b.

Secondary - Temp. (B21-TR-R614, points 1-11)

BRUNSWICK - UNIT 2 3/4 3-51 Amendment No.

8307260504 830722 PDR ADOCK 05000324 P

- --- R..

PD

?

T:

i g

E TABLE 4.3.5.3-1 E

f POST-ACCIDENT MONITORING INSTRUMENTATION SURVEILLANCE REQUIREMENTS

,3 CHANNEL CHANNEL

~

E INSTRUME!ff AND INSTRUMENT NUMBER CHECK CALIBRATION 4-f.

.A w

1.

Reactor Vessel Pressure M

R (821-Pl-R004 A,B; C32-LPR-R608; and C32-PT-N005A,B) 2.

Reactor Vessel Water Level.

M R~

(B21-LITS-N026A,B; B21-LR-R615; B21-LI-R604A,B; B21-LT-NO37; and B21-LTM-NO37-1)

M R

3.

Suppression Chamber Water Level (CAC-LT-2601; CAC-LI-2601-1; CAC-LT-2602; CAC-LR-2602)

M R

4.

Suppression Chamber Water Temperature (CAC-TR-1258-14, 21; and C91-P602)

M R

5.

Suppression Chamber Atmosphere Temperature (CAC-TR-1258-17 thru 20; and C91-P602)

M R

u 6.

Drywell Pressure (CAC-PI-4176; CAC-PT-4176; CAC-PR-1257-1; and CAC-PT-4175)

M R

7.

Drywell. Temperature (CAC-TR-1258-1 thru 13, 22, 23, 24; and C91-P602)

M' R

8.

Drywell Radiation (CAC-AR-1260; CAC-AQH-1260-1,2,3; CAC-AR-1261; CAC-AQH-1261-1,2,3; CAC-AR-1262; and CAC-AQH-1262-1,2,3)

~~

~

M R

9.

Drywell Oxygen Concentration (CAC-AT-1259-2; CAC-AR-1259; CAC-AT-1263-2; and CAC-AR-1263) k.

10.

Drywell Hydrogen Concentration M

R g,

(CAC-AT-1259-1; CAC-AR-1259; CAC-AT-1263-1; and CAC-AR-1263).

a g

11.

Safety Relief Valve Position Indication Primary - Sonic (B21-FY-4157 thru 4167)

M R

a.

i p

b.

Secondary - Temp. (B21-TR-R614, points 1-11)

M R

e 4