l-REACTOR COOLANT SYSTEM OVERPRESSURE-PROTECTION-SYSTEMS

~

LIMITING CONDITION FOR OPERATION

-3.4.9.3 At-least one of the following overprocsure protection

-systems shall be-OPERABLE:

a.

Two power operated relief valves (PORVs) with a nominal trip l setpoint of s 440 psig, or b.

A reactor coolant system vent of 2 3.14 square inches.

APPLI P 21LITi:

When the temperature of one or more of the non-imolated RCS cold legs is 5 an enable temperature of 292*F.

l

-ACTION:

a.

With one PORV inoperable, either restore the inoperable PORV to OPERABLE status within 7 days or depressurize and vent the RCS through a 3.14 square inch vent (s) within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />; maintain the RCS in a vented condition until both PORVs _have been restored to OPERABLE statu<:.

Refer to Technical Specification 3.4.1.6 for further limitations,

.b.

With-_both PORV's inoperable, depressuri~e and vent _the_RCS i

through a 3.14 square inch vent (s) within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />; maintain the RCS in a

vented condition until both PORVs have baen restored-to OPERABLE status.

c.

The provisions of specification 3.0.4 are not applicable.

SURVEILLANCE REQUIREMENT 4.4.9.3.1 Each PORV shall be demonstrated OPERABLE BY:

b a

BEAVER VALLEY - UNIT 1 3/4 4-27a i

Proposed 9107310002 910725 PDR ADOCK 05000334 P

PDR

_ _ _ _..