pea,It u
f UNITED STATES j
j NUCLEAR REGULATORY COMMISSION f
WASHINGTON, D.C. 20555 4 001 o
49.....,o SOUTH CAROLINA ELECTRIC & GAS COMPANY
~ SOUTH CAROLINA PUBLIC SERVICE AUTHORITY DOCKET NO. 50-395 VIRGIL C. SUMMER NUCLEAR STATION. UNIT NO. 1 AMENDMENT TO FACILITY OPERATING LICENSE L
Amendment No. 117 License No. NPF-12 i
1.
The Nuclear Regulatory Commission (the Comission) has found that:
A.
The application for amendment by South Carolina Electric & Gas Company (the licensee), dated February 25, 1994, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Comission's rules and regulations set forth in 10 CFR Chapter I; B.
The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Comission; C.
There is reasonable assurance (1) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Comission's regulations; D.
The issuance of this amendment will not be inimical to the comon defense and security or to the health and safety of the public; and E.
The issuance of this amendment is in accordance with 10 CFR Part 51 of the Comission's regulations and all applicable requirements have been satisfied.
2.
Accordingly, the license is amended by changes to the Technical Specifications, as indicated in the attachment to this license amendment; and paragraph 2.C.(2) of Facility Operating License No.
NPF-12 is hereby amended to read as follows:
J 9409220073 940906 PDR ADOCK 05000395 P
o.:
\\
.: (2)
Technical Specifications and Environmental Protection Plan The Technical Specifications contained in Appendix A, as revised through Amendment No.
, and the Environmental Protection Plan contained in Appendix B, are hereby incorporated in the license.
South Carolina Electric & Gas Company shall operate the facility in accordance with the Technical Specifications and the Environmental Protection Plan.
3.
This amendment is effective as of its date of issuance and shall be implemented within 30 days of issuance.
FOR THE NUCLEAR REGULATORY COMMISSION d)b
~
David B. Matthews, Director Project Directorate 11-1
+
Division of Reactor Projects - I/II t
Office of Nuclear Reactor Regulation
Attachment:
Changes to the Technical Specifications
^
Date of Issuance:
September 6, 1994 l
t
ATTACHMENT TO LICENSE AMENDMENT NO.
TO FACILITY OPERATING LICENSE NO. NPF-12 DOCKET NO. 50-395 Replace the following pages of the Appendix A Technical Specifications with the enclosed pages.. The revised pages are indicated by marginal lines.
Remove Paaes Insert Paaes 1-4 1-4 1-5 1-5 3/4 3 3/4 3-26 3/4 3-30 3/4 3-30 3/4 3-34 3/4 3-34 3/4 3-67 3/4 3-67 3/4 3-70 3/4 3-70 i
6-3 6-3 6-6 6-6 6-8 6-8 6-9 6-9 6-11 6-11 6-12 6-12 6-12a 6-12a 6-12b 6-12b 6-14 6-14 6-15 6-15 6-16 6-16 6-20 6-20 9
'l
-m
k %:
DEFINITIONS l<
OFFSITE DOSE CALCULATION MANUAL (00CM) 1.17 The 0FFSITE DOSE CALCULATION MANUAL (ODCM) shall contain the methodology and parameters used in the calculation of offsite doses resulting from radioactive gaseous and liquid effluents, in the calculation of gaseous and-liquid effluent monitoring Alarm / Trip Setpoints, and in the conduct of the l
Environmental Radiological Monitoring Program. The 00CM shall also contain (1) the Radioactive Effluent Controls and Radiological Environmental Monitoring Programs required by Section 6.8.4 and (2) descriptions of the information that should be included in the Annual Radiological Environmental Operating and Annual Radioactive Effluent Release Reports required by l
Specifications 6.9.1.6 and 6.9.1.8.
OPERABLE - OPERABILITY 1.18 A system, subsystem, train, component or device shall be OPERA 8LE or have OPERA 8ILITY when it is capable of performing its specified function (s),
and when all necessary attendant instrumentation, controls, electrical power, cooling or seal water, lubrication or other auxiliary equipment that are required for the system, subsystem, train, component or device to perfom its function (s) are also capable of performing their related support function (s).
OPERATIONAL MODE - MODE 1.19 An OPERATIONAL MODE (i.e., MODE) shall correspond to any one inclusive combination of core reactivity condition. power level and average reactor coolant temperature specified in Table 1.1.
PHYSICS TESTS 1.20 PHYSICS TESTS shall_be those tests perfomed to measure the fundamental nuclear characteristics of the reactor core and related instrumentation and
- 1) described in Chapter 14.0 of the FSAR, 2) authorized under the provisions of10CFR50.59,or3)otherwiseapprovedbytheCommission.
-1.21 PRESSUREBOUNDARYLEAKAGEshallbeleakage(exceptsteamgeneratortube leakage) through a non-isolable fault in a Reactor Coolant System component body, pipe wall or vessel wall.
PROCESS CONTROL PROGRAM (PCP) 1.22 The PROCESS CONTROL PROGRAM (PCP) shall contain the current formulas, sampling, analyses, tests, and determinations to be made to ensure that processing and packaging of solid radioactive wastes based on demonstrated processing of actual or simulated wet solid wastes wil be accomplished in such a way as to assure compliance with 10 CFR Parts 20, 61, and 71 State regulations, burial ground requirements, and other requirements governing the disposal of solid radioactive waste.
i i
Sul#4ER - UNIT 1 1-4 Amendment No. 194.117
DEFINITIONS PURGE - PURGING 1.23 PURGE or PURGING is the controlled process of discharging air or gas from a confinement to maintain temperature, pressure, humidity, concentration or other operating condition in such a manner that replacement air or gas is required to purify the confinement.
i QUADRANT POWER TILT RATIO 1.24 detector calibrated output to the average of the upper exco brated outputs, or the ratio of the maximum lower excore detector calibrated output to the average of the lower excore detector calibrated outputs, whichever is greater. With one excore detector ino shall be used for computing the average. perable, the remaining three detectors RATED THERMAL POWER 1.25 RATED THERMAL POWER shall be a total reactor core heat tran the reactor coolant of 2775 MWt.
REACTOR TRIP SYSTEM RESPONSE TIME 1.26 The REACTOR TRIP SYSTEM RESPONSE TIME shall be the time when the monitored parameter exceeds its trip setpoint at the channel sensor until loss of stationary gripper coil voltage.
REPORTABLE EVENT 1.27 A REPORTA8LE EVENT shall be arty of those conditions specified in Section 50.73 to 10 CFR Part 50.
SHUTDOWN MARGIN 1.28 SHUTDOWN MARGIN shall be the instantaneous amount of reactivity by which the reactor is subcritical or would be subcritical from its present condition assuming all full length rod cluster assemblies (shutdown and control) are fully inserted except for the single rod cluster assembly of hghest reactivity worth which is assumed to be fully withdrawn.
SLAVE RELAY TEST 1.29 A SLAVE RELAY TEST shall be the ener verification of OPERABILITY of each relay.gization of each slave relay and The SLAVE RELAY TEST shall include a continuity check, as a minimum, of associated testable actuation devices.
j 1.30 Not Used SOURCE CHECK 1.31 A SOURCE CHECK shall be the qualitative assessment of channel response when the channel sensor is exposed to a radioactive source.
SulWER - UNIT 1 1-5 Amendment No. 75,W4,117
TABLE 3.3-4 (Continued) r E
ENGINEERED SAFETY FEATURE ACTUATION SYSTEM INSTRUMENTATION TRIP SETPO y
Total
.o' Functional Unit Allowance (TA) Z S
Trio Setootnt Allowable Value 3.
CONTAINMENT ISOLATION
- a. Phase "A" Isolation 1.
Manual NA NA NA NA NA 2.
Safety Injection See 1 above for all safety injection setpoints and allowable values 3.
Automatic Actuation Logic NA NA.
NA NA R
and Actuation Relays NA s.
i'
- b. Phase "B" Isolation U
1.
Automatic Actuation MA M
NA NA NA Logic and Actuation Relays 2.
Reactor Building 3.0 0.71 1.5 512.05 psig
$12.31 psig Pressure-High 3
- c. Purge and Exhaust Isolation
=
1.
Safety Injection See.1 above for all safety injection setpoints and allowable values 2.
Containment Radtoactivity NA NA NA High
~
C 3.
Automatic Actuation MA NA NA NA NA Logic and Actuation Relays
- Trip setpoints shall be set to ensure that the limits of 00CM Specification 1.2.2.1 are not exceeded.
l m
- _.-, i-
m--
ca.:
INSTRLMENTATION TABLE 3.3-5 (Continued)
ENGINEERED SAFETY FEATURES RESPONSE TIMES INITIATING SIGNAL AND FUNCTION RESPONSE TIME IN SECONDS e.
Reactor Building Purge and Not Applicable Exhaust Isolation f.
EmergencyFeehaterPumps.
Not Applicable g.
Service Water System 171.5(4)/81.5(5) h.
Reactor Building Cooling Units
$76.5(4)/86.5(5) l 1.
Control Room Isolation Not Applicable 3.
Pressurizer Pressure-Low a.
Safety Injection (ECCS) 527.0(2)/27.0(1) b.
ReactorTrip(fromSI) 53.0 c.
Feedwater Isolation
$10.0 d.
Containment Isolation -Phase 'A'
$45.0(4)/55.0(5) e.
Reactor Building Purge and Not Applicable Exhaust Isolation f.
Emergency Feedwater Pumps Not Applicable g.
Service Water Systaa
$71.5(4)/81.5(5) h.
Reactor Building Cooling Units
$76.5(4)/86.5(5) 1.
Control Room Isolation Not Applicable 4.
Differential Pressure Between Steam Lines-High a.
Safety Injection (ECCS) 527.0(2)/37.0(3) b.
Reactor Trip (from SI) 53.0 c.
Feedwater Isolation
$10.0 d.
Containment Isolation -Phase 'A' 545.0(4)/55.0(5)
'0' SUM 4ER - UNIT 1 3/4 3-30
~
INSTRUMENTATION l
TABLE 3.3-5 (Continued) 1 TABLE NOTATION (1)
Diesel generator starting and sequence loading delays from under l
voltage included. Response time limit includes positioning of valves to establish SI path and attainment of discharge pressure for centrifugal charging pumps and RHR pumps. Sequential transfer of centrifugal charging pump suction from the VCT to the RWST (RWST valves open, then VCT valves close) is not included.
(2)
Diesel generator starting delay gLt included. Sequence loading delay l
included. Offsite power available. Response time limit includes positioning of valves to establish SI path and attainment of discharge pressure for centrifugal charging pumps. Sequential transfer of egntrifugal charginq pump suction from the VCT to the RWST (RWST valves open, then VC" valves close) is included.
(3)
Diesel generator starting and sequence loading delays from under voltage included. Response time limit includes positioning of valves-to establish SI path and attainment of discharge pressure for centrifugal charging pumps. Sequential transfer of centrifugal charging pump suction from the VCT to the RWST (RWST valves open, then the VCT valves close) is included.
(4)
Diesel generator starting delay g g included. Sequence loading delay included. Offsite power available.
(5)
Diesel generator starting and sequence loading delays from undervoltage included.
SUMMER - UNIT 1 3/4 3-34 Amendment No. M 8,117
3 INSTRUMENTATION EXPLOSIVE GAS MONITORING INSTRUMENTATION LIMITING CONDITION FOR OPERATION 3.3.3.9 The explosive gas monitoring instrumentation channels shown in Table 3.3-13 shall be OPERABLE with their alarm / trip setpoints set to ensure that the limits of Specification 3.11.2.5 are not exceeded.
l, APPLICABILITY: As shown in Table 3.3-13 ACTION:
With an explosive gas monitoring instrumentation channel alarm / trip l
a.
setpoint less conservative than required by the above Specification, declare the channel inoperable and take the ACTION.shown in Table l
3.3-13.
I b.
With less than the minimum number of explosive gas monitorinq
[
instrumentation channels OPERABLE take the ACTION shown in "able 3.3-13.
Restore the inoperable instrumentation to operable status within 30 days and, if unsuccessful prepare and submit a Special Report to the Commission pursuant to Specification 6.9.2 to explain why this inoperability was not corrected in a timely manner.
The provisions of Specifications 3.0.3 and 3.0.4 are not applicable.
l c.
SURVEILLANCE REOUIREMENTS 4.3.3.9 Each explosive gas monitoring instrumentation channel shall be demonstrated OPERABLE by performance of the CHANNEL CHECK, CHANNEL CALIBRATION and ANALOG CHANNEL OPERATIONAL TEST operations at the frequencies shown in li 7
Table 4.3-9.
t
[
i 3
k SUMMER - UNIT 1 3/4 3-67 Amendment No. 35 J04.ll7
bd if8 mai mgu m
da 5$
E e
aXM 8
g&W u
af O
g U
oc8 g
5 dc h
h!
$5 x
va l
6 e
x
~
ME Ed gg e
=
=
E m5 5
G t
9 m
.r, S
5M5 k
MM b
- E $5 E
g_
.e E
s g
ge
=
_g n 2
.x w
5 i
M2 d
SUMMER - UNIT 1 3/4 3-70 Amendment No. 79,J94,117
3 ADMINISTRATIVE CONTROLS' 6.2.3 INDEPENDENT SAFETY ENGINEERING GROUP (ISEG)
FUNCTION 6.2.3.1 The ISEG shall function to examine plant operating characteristics NRC issuances, industry advisories, Licensee Event Reports and other sources.
of plant design and operating experience information, including plants of similar design, which may indicate areas for improving plant safety.
s COMPOSITION 6.2.3.2 The ISEG shall be composed of a multi-disciplined dedicated onsite group with a minimum assigned complement of five engineers or appropriate specialists.
RESPONSIBILITIES.
i 6.2.3.3 The ISEG shall be responsible for maintaining surveillance of plant activities to provide independent verification
- that these activities are performed correctly and that human errors are reduced as much as practical.
~
AUTHORITY 6.2.3.4 The ISEG shall make detailed reconnendations for procedure i
revisions, equipment modifications, maintenance activities,. operations activities or other means of improving plant safety to the General Manager, J
Nuclear Safety.
6.2'.4 SHIFT TECHNICAL ADVISOR i
The Shift Technical Advisor shall provide technical support to the Shift Supervisor in the areas of thermal hydraulics, reactor engineering and plant analysis with regard to the safe operation of the unit.
6.3 UNIT STAFF OUALIFICATIONS 6.3.1 Each member of the unit staff shall meet or exceed the minimum qualifications of ANSI N18.1-1971 for comparable positions except for the Radiation Protection Manager who shall meet or exceed the qualifications of Regulatory Guide 1.8 September 1975, and the members of the Independent Safety Engineering Group, each of whom shall have a Bachelor of Science degree or registered Professional Engineer and at least two years experience in their field. At least one year experience shall be in the nuclear field.
6.4 NOT USED l
- Not responsible for sign-off function.
SUMMER - UNIT 1 6-3 Amendment No. 78,58,79,706,117
. ~_
.. i i
ADMINISTRATIVE CONTROLS RECORDS i
6.5.1.8 The Plant Safety Review Committee shall maintain written minutes of each PSRC meeting.that, at a minimum, document the results of all PSRC activ-ities performed under the responsibility and authority provisions of these technical specifications.
Copies shall be provided to the Vice President, Nuclear Operations, and the Chairman of.the Nuclear Safety Review Committee.
6.5.2 NUCLEAR SAFETY REVIEW COMMITTEE (NSRC)
FUNCTION 6.5.2.1 The Nuclear Safety Review Committee shall function to provide independent review and audit of designated activities in the areas of:
a.
nuclear power plant operations b.
nuclear engineering c.
chemistry and radiochemsitry d.
metallurgy e.
instrumentation and control f.
radiological safety g.
mechanical and electrical engineering h.
quality assurance practices COMPOSITION 6.5.2.2 NSRC shall consist of a Chairman and four or more other members appointed by the Vice President, Nuclear Operations. No more than a minority l
of the members of the NSRC shall have line responsibility for the operation of the unit.
The NSRC members shall hold a Bachelor's degree in an engineering or physical science field or equivalent experience and a minimum of five years of technical experience of which a minimum of three years shall be in one or more of the disciplines of 6.5.2.la through h.
In the aggregate, the membership of the committee shall provide specific practical experience in the majority of the disciplines of 6.5.2.la through h.
ALTERNATES 6.5.2.3 All alternate members shall be appointed in writing by the Vice President, l Nuclear Operations; however, no more than two alternates shall participate as voting members in NSRC activities at any one time.
CONSULTANTS 6.5.2.4 Consultants shall be utilized as determined by the NSRC Chairman to provide expert advice to the NSRC.
SUMMER ~- UNIT 1 6-6 Amendment No. 18,79,117
9-ADMINISTRATIVE CONTROLS AB[T,[
6.5.2.8 The NSRC shall have cognizance of the audits listed below. Audits may be perfomed by using established SCE&G groups such as the ISEG and QA or by outside groups as determined by the NSRC.
Audit reports or susumaries will be' the basis for NSRC action:
The conformance of unit operation to provisions contained within the a.
Technical Specifications and applicable license conditions.
l b.
The performance, training and qualifications of the entire unit staff.
l The results of acticns taken to correct defir:1encies occurring in c.
unit equipment, structures, systems or method of operation that affect nuclear safety.
l d.
The perfomance of activities required by the Operational Quality j
Assurance Program to meet the criteria of Appendix "B", 10 CFR 50.
ll The Emergency Plan and implementing procedures.
e.
l f.
The Security Plan and implementing procedures.
l g.
Any other area of unit operation considered appropriate by the NSRC or the Vice President, Nuclear Operttions.
li h.
The Fire Protection Program and implementing procedures.
l 1.
An independent fire protection and loss prevention inspection and audit shall be perfomed annually utilizing either qualified offsite licensee personnel or a qualified outside firm.
j.
An inspection and audit of the fire protection and loss prevention program shall be performed by an outside qualified fire consultant at intervals no greater than 3 years.
k.
The radiological environmental monitoring program and the results thereof, including the performance of activities required by the quality assurance program per R.G. 4.15 Rev. 1, February 1979.
l 1.
The OFFSITE DOSE CALCULATION MANUAL and implementing procedures.
[
The PROCESS CONTROL PROGRAM and implemating procedures for m.
solidification of radioactive wastes.
l AUTHORITY 6.5.2.9 The NSRC shall report to and advise the Vice President, Nuclear l
Operations, on those areas of responsibility specified in Sections 6.5.2.7 and 6.5.2.8.
Sul44ER - UNIT 1 6-8 Amendment No. 18,12,19.117
~
1 ADMINISTRATIVE CONTROLS RECORDS 6.5.2.10 Records of NSRC activities shall be prepared, approved and distrib td as indicated below, i
Minutes of each NSRC meeting shall be prepared, approved and forwarded a.
I to the Vice President Nuclear Operations, within 14 days following lt each meeting.
~
b.
Reports of reviews encompassed by Section 6.5.2.7 above, shall be pre-pared, approved and forwarded to the Vice President Nuclear Operations, within 14 days following completion of the review.
Audit summary reports encompas:ed by Section 6.5.2.8 above, shall be
.'l c.
forwarded to the NSRC and the Vice President, Nuclear Operations.
Full audits shall be forwarded to the management positions responsible for the areas audited within 30 days after completion of the audit by the auditing organization.
6.5.3 TECHNICAL REVIEW AND CONTROL ACTIVITIES
-(
6.5.3.1 Activities which affect nuclear safety shall be conducted as follows-I Procedures required by Technical Specification 6.8 and other proce-l a.
dures which affect plant nuclear safety, and changes thereto, shall be prepared, reviewed and approved. Each such procedure or procedure change shall be reviewed by an individual / group other than the individual / group which prepared the procedure or procedure change, but who may be from the same organization as the individual / group which j
prepared the procedure or procedure change. Procedures other than 1
Administrative Procedures will be approved as delineated in writing by i
the General Manager, Nuclear Plant Operations. The General Mana Nuclear Plant Operations will approve administrative procedures,ger.
d security implementing procedures.and emergency plan implementing procedures. Temporary approval to procedures which clearly do not 1
change the intent of the approved procedures can be made by two members of the plant management staff, at laast one of whom hclds a j
Senior Reactor Operator's License. For_ changes to procedures which
-i may involve a change in intent of the approved procedures, the person authorized above to approve the procedures shall approve the change.
1 i
b.
Proposed changes or modifications to plant nuclear safety-related structures, systems and components shall be reviewed-as designated by the General Manager, Nuclear Plant Operations. Each such modifica-tion shall be designed as authorized by Engineering Services and shall be reviewed by an individual / group other than the individual /
group which designed the modification, but who may be from the same i
organization as the individual / group which designed the modifications.
Implementation of modifications to plant nuclear safety-related structures, systems and components shall be concurred in by the General Manager Nuclear Plant Operations.
1 i
SUtMER - UNIT 1 6-9 Amendment No. 35,79,117 1
s ADMINISTRATIVE CONTROLS d.
Critical operation of the unit shall not be resumed until authorized by the Commission.
6.8 PROCEDQESANDPROGRAMS i
6.8.1 Written procedures shall be established, implemented and maintained covering the activities referenced below:
The applicable procedures recomunended in Appendix "A" of Regulatory a.
Guide 1.33, Revision 2 February 1978.
b.
Refueling operations.
I Surveillance and test activities of safety-related equipment.
c.
Security Plan.
i d.
e.
f.
g.
h.
OFFSITE DOSE CALCULATION MANUAL.
1.
Effluent and environmental monitoring program using the guidance in Regulatory Guide 4.15. Revision 1. February 1979.
6.8.2 Each procedure of 6.8.1 above, and changes thereto, shall be reviewed
~
prior to implementation as set forth in 6.5 above.
6.8.3 NOT USED.
j 6.8.4 The following programs shall be established, implemented and maintained:
9 a.
Primary Coolant Sources Outside Containment A program to reduce leakage from those portions of systems outside containment that could contain highly radioactive fluids during a serious transient or accident to as low as practical levels. The systems include the chemical and volume control,~ letdown, safety injection, residual heat removal, nuclear sampling, liquid radwaste
- 1 handling, gas radweste handling and reactor building spray system.
The program shall include the following:
(1) Preventive maintenance and periodic visual inspection requirements, and (ii)
Integrated leak test requirements for each system at refueling cycle intervals or less.
b.
In-Plant Radiation Monitoring Training of personnel,
((
Procedures for monitoring, and 1
Provisions for maintenance of sampling and analysis equipment.
SIM4ER - UNIT 1 6-11 Amendment No.18,H,12,#,117 i
- l
9 ADMINISTRATIVE CONTROLS
~
c.
Secondary Water Chemistry I
i A program for monitoring of secondary water chemistry to inhibit steam generator tube degradation. This program shall include:
(1)
Identification of a sampling schedule for the critical variables and control points for these variables, (ii)
Identification of the procedures used to measure the values of the critical variables, (iii)
Identification of process sampling points, including monitoring the discharge of the condensate pumps for evidence of condenser in-leakage.
(iv) Procedures for the recording and management of data.
(v) Procedures defining corrective actions for all off-control point chemistry conditions, i
(vi) A procedure identifying ~(a) the ' authority responsible'for the interpretation of the data, and (b) the sequence and timing of administrative events required to initiate corrective action.
d.
Postaccident Samplina A program which will ensure the capability to obtain and analyfe reactor coolant, radioactive iodines and particulates in plant gaseous effluents, and containment atmosphere samples under accident 1
conditions.
The program shall include the following:
Training personnel, i
(
Procedures for sampling and analysis, (1
Provisions for maintenance of sampling and analysis equipment.
e.
Radioactive Effluent Controls Program l
l A program shall be provided conforming with 10 CFR 50.36a for the control of radioactive affluents and for maintaining the doses to members of the public from radioactive effluents as low as reasonably achievable. The program (1) shall be :ontained in the 00CM, (2) shall l'
be implemented by operating procedures, and (3) shall include remedial actions to be taken whenever the program limits are exceeded. The program shall include the following elements.
i 1)
Limitations on the operability of radioactive liquid and gaseous monitoring instrumentation including surveillance tests and setpoint determinations in accordance with the methodology in i
the 00CM..
2)
Limitations on the concentration of radioactive material released in liquid effluents to unrestricted areas confoming to l
10 CFR Part 20 Appendix 8. Table II, Column 2; SIM1ER - UNIT 1 6-12 Amendment No.
~
m ADMINISTRATIVE CONTROLS o:
Radioactive Effluent Controls Procram (Continued) e.
3)
Monitoring, sampling, and analysis of radioactive liquid and l
gaseous effluents in accordance with 10 CFR 20.106 and with the methodology and parameters in the 00CM; 4)
Limitations on the annual and quarterly doses or dose commitment to a member of the public from radioactive materials in liquid effluents released to unrestricted areas conforming to Appendix I to 10 CFR Part 50; 5)
Determination of cumulative and projected dose contributions from radioactive effluents for the current calendar quarter and current calendar year in accordance with the methodology and parameters in the 00CM at least every 31 days; i
6)
Limitations on the operability and use of,the liquid and gaseous effluent treatment systems to ensure that the appropriate portions of these systems are used to reduce releases or radioactivity when the projected doses in a 31-day period would exceed 2 percent of the guidelines for the annual or dose consitment conforming to Appendix I to 10 CFR Part 50; 7)
Limitations on the dose rate resulting from radioactive material released in gaseous effluents to areas beyond the site boundary conforming to the doses associated with.10 CFR Part 20, Appendix
- 8. Table II, Column 1; 8)
Limitations on the annual'and quarterly air doses resulting from noble gases released in gaseous effluents to areas beyond the site boundary conforming to Appendix I to 10 CFR Part 50; i
9)
Limitations on the annual and quarterly doses to a member of the public from Iodine-131 Iodine-133, tritium, and all radionuclides in particulate from with half-lives greater than 8 days in gaseous affluents released to areas beyond the site boundary conforming to Appendix I to 10 CFR Part 50; t
i 10)
Limitations on the annual dose or dose commitment to any member of the public due to releases of radioactivity and to radiation i
from uranium fuel cycle sources conforming to 40 CFR Part 190.
f.
Radiolooical Environmental Monitorino Program I
~
A program shall be provided to monitor the radiation and radionuclides in the environs of the plant. The program shall provide (1) representative measures of radioactivity in the l
highest potential exposure pathways, and 2 verification'of the accuracy of the effluent monitoring progra(m)and modeling of environmental exposure pathways. Theprogramshall_(1)becontained
{
in the 00CM, (2) conform to the guidance of Appendix I to 10 CFR Part l
j 50,and(3)includethefollowing:
l l
1)
Monitoring, sampling, analysis, and reporting of radiation and radionuclides in the environment in accordance with the methodology and parameters in the ODCM; StM4ER - UNIT 1 6-12a Amendment No. IN,117 l'
.-~
s.'
s ADMINISTRATIVE CONTROLS e:
l
'Radiolocical Environmental Monitorina Procram (Continued) l, f.
2)
A Land Use Census to ensure that changes in the use of areas at
' ~;
and beyond the site boundary are identified and that modifications to the monitoring program are made if required by the results of the census; and~
3)
Participation in an 1.nter-laboratory Comparison Program to i
ensure that independent checks on the precision and accuracy of measurements of radioactive materials in environmental sample matrices are performed as part of the quality assurance program for environmental monitoring..
i 1
}
i SIM4ER - UNIT 1 6-12b Amendment No. 194,117
s.Y c
ADMINISTRATIVE CONTROLS e:
l This report shall also include the results of specific activity analysis.in which the primary coolant exceeded the limits of specification 3.4.8..The following information shall be included:
(1) Reactor power history starting t
48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> prior to the first sample in which the limit was exceeded; (2) Results of the last isotopic analysis for radiciodine perfomed prior to exceeding the limit, results of analysis while limit was exceeded and results of one analysis after the radiciodine activity was reduced to less than limit. Each result should include date and time of sampling and the radiciodine concentrations; l
(3) Clean-up system flow history starting 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> prior to the first sample in which the limit was exceeded; (4) Graph of the I-131 concentration and one other radisiodine isotope concentration in microcuries per gram as a function of time for the duration of the specific activity above the steady-state level; and (5) The time duration when the specific activity of the primary coolant exceeded the radiofodine limit.
ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT f
5.9.1.6 The annual radiological environmental operating report covering the-operation of the unit during the previous calendar year shall be submitted before May 1 of each year.
I The report shall include suimmaries, interpretations, and an analysis of trends i
of the results of the radiological environmental monitoring program for the reporting period. The material provided shall be consistent with the objectives outlined in (1) the ODCM and (2) Sections IV.E.2, IV.8.3, and IV.C of Appendix I to 10 CFR Part 50.
6.9.1.7 Not used.
ANNUAL RADI0 ACTIVE EFFLUENT RELEASE REPORT l
6.9.1.8 Annual radioactive effluent release report covering the operation l
of the unit during the previous 12 months of operations shall be submitted within 60 days after January 1 of each year.
1' The report shall include a summary of the quantities of radioactive liquid and gaseous effluents and solid waste released from the unit. The material provided shall be (1) consistent with the objectives outlined in the ODCM and PCP and (2) in conformance with 10 CFR 50.36a and Section IV.B.1 of Appendix I to 10 CFR Part 50.
fi i
l i
u l
l
\\
i SUM 4ER - UNIT 1 6-14 Amendment No. 19,714,117 l ~'
)
s :.
c, ;
This page left blank intentionally.
SUMER - UNIT 1 6-15 AmendmentNo.S,f),Jpf, l
11
= - -
s l, ADMINISTRATIVE CONTROLS w:
6.9.1.9 Not used.
MONTHLY OPERATING REPORT 6.9.1.10 Routine reports of operating statistics and shutdown experience, in-ciuding documentation of all challenges to the PORV's or safety valves, shall be submitted on a monthly basis to the Director, Office of Resource Management,.
U.S. Nuclear Regulatory Comunission, Washington, D.C.
20555, with a copy to the Regional Office of Inspection and Enforcement, no later than the 15th of each month following the calendar month covered by the report.
A report of any major changes to the radioactive waste treatment systems shall be submitted with the Monthly Operating Report for the period in which the evaluation was reviewed and accepted as set forth in 6.5 above.
CORE OPERATING LIMITS REPORT 6.9.1.11 Core operating limits shall be established and documented in the CORE OPERATING LIMITS REPORT prior to each reload cycle, or prior to any remaining portion of a reload cycle, for the following:
Moderator Temperature Coefficient BOL and E0L Limits and 300 ppa a.
surveillance limit for Specification 3/4.1.1.3, b.
Shutdown Rod Insertion Limit for Specification 3/4.1.3.5, Control Rod Insertion Limits for Specification 3/4.1.3.6, c.
d.
Axial Flux Difference Limits, target band, and APLND for Specification 3/4.2.1, e.
Heat Flux Hot Channel Factor F
,K(Z),W(Z),APL andW(Z)BL for Specification 3/4.2.2, RTP f.
Nuclear Enthalpy Rise Hot Channel Factor, FaH, and Power Factor Multiplier, PFaH, limits for Specification 3/4.2.3.
The analytical methods used to determine the core operating limits shall.be those previously reviewed and approved by the NRC, specifically those described in the following documents.
)
WCAP.-9272-P-A, " WESTINGHOUSE RELOAD SAFETY EVALUATION METH000!TY,"
a.
July 1985 (W Proprietary).
n d
J SUPMER - UNIT 1 6-16 Amendment No. 19,88,104,11 7
I o *.
ADMINISTRATIVE CONTROLS o:
6.14 0FFSITE DOSE CALCULATION MANUAL (ODCM) 6.14.1 The 00CM shall be approved by the Consission prior to implementation.
6.14.2 Changes to the ODCM:
Shall be documented and records of reviews performed shall be a.
retained as required by Specification 6.10.2.o.
This documentation shall contain:
1)
Sufficient information to support the change together with appropriate analyses or evaluations justifying the change (s);
and 2)
A determination that the change will maintain the level of radioactive effluent control-required by 10 CFR 20.106, 40 CFR Part 190, 10 CFR 50.36a, and Appendix ! to 10 CFR Part 50 and not adversely impact the accuracy or reliability of effluent dose or setpoint calculations.
b.
Shall become effective'after review and acceptance by the PSRC and i
the approval of the General Manager, Nuclear Plant Operations.
Shall be submitted to the Commission in the form af a complete c.
legible copy of the entire 00CM as a part of or concurrent with the Annual Radioactive Effluent Release Report for the period of the l !
report in which any change to the 00CM was made. Each change sha'11 l
be identified by markings in the margin of the affected pages, clearly indicating the area of the page that was changed, and shall indicatethedate(e.g., month / year)thechangewasimplemented.
l t
i I
l i
SLM4ER - UNIT 1 6-20 Amendment No. AI,79.J04.117 i