g PUBLIC SERVICE COMPANY OF COLORADO spp-37 FORT ST. VRAliM NUCLEAR GENERATlWG STATION lssue 15 Page 1 of 2 l TITLE:

RERP INVEiiTORY LIST ISSUANCE AUTHORIZED PORC U

EFFECTIVE REVIEW Pone 4 8 4 SEP 2'J 1982 DATE 10 SL 1.0 PURPOSE To establish a procedure for inspecting the contents of the Radiological Emergency Kits.

2.0 APPLICABILITY Inspection of the contents of the emergency kits will'be done on j

a quarterly basis to insure all equipment is in an operable i

condition and all contents as listed on the applicable check list are accounted for.

I 3.0 GENERAL REQUIREMENTS l'

The locations of the Radiological Emergency Kits are the Fort St. Vrain Warehouse, the Engineering / Quality Assurance / Training Complex, and the Technical Support Center.

l 4.0 PROCEDURE 4.1 Check all the contents of the Radiological Emergency Kit

~

against the applicable check list and correct any discrepancies.

i l

l 4.2 Insure all equipment is operational.

4.3 Replace tape and batteries as necessary.

4.4 Check calibration and/or inspection dates where applicable and replace as necessary.

l 4.5 Indicate all discrepancies,

reason, and estimate I

correction date.

5.0 REFERENCES

None FORM 372 22 3842 8306300107 921117 PDR ADDCK 05000267 PDR

.Q

PUBLIC SERVICE COMPANY OF COLORADO HPP-37 FORT ST. VRAIM NUCLEAR GENERATING STATION 2

2 I

6.0 ATTACHMENTS l

HPP-37A:

Radiological Emergency Kit Check List.

I HPP-37B Eab, EP2 Survey Team Inventory List l

HPP-37C Technical Support Center Inventory List l

HPP-370 Health Physics Area Emergency Supplies l

HPP-37E Control Room Emergency Supplies l

HPP-37F Decontamination Equipment Supplies l

HPP-37G Emergency Respiratory Protective Equipment l

HPP-37H Inspection Results a

4 F OR M 372 3643

(

PUBLIC SERVICE COMPANY OF COLORADO Attach. HPF-37A FORT ST. VR AIN NUCLEAR GENERATING STATION y

fg 4

i l

PERSONNEL CONTROL CENTER INVENTORY LIST 1

l00AN.i ITEM (PSC WHSE.[ENG./0.A.l REMARKS l

i l

l l

1 1

I i

l 2 IKeys to Lonomont Service Cntr. l l

l

[

l l

I I

I I

l 2 l Keys to Johnstown County Shoo l

l l

l i

i i

I I

i i

{

l 1

lAssionment Board l

l l

l j

l I

I I

I i

l l

1 ISet of Maos l

1 l

l I

I I

I I

i l

1 l Log Book l

l l

l l

1 1

I I

1 l

2 l Pencils l

l l

l l

l l

i l

l l

2 l Wax Pencils (Black & Red) l l

l l

l l

1 I

I I

l 2 l Wax Pencil Fillers (Black & Red)l l

l l

l l

l l

1 1

I

~l 11 IE Kit Instruction Books w/ Vests l l

l l

l l

l l

1 1

1 1

l Copy Health Physics Procedures l l

l l

l l

l 1

1 I

I l

1 l Copy Emergency Procedures l

l l

l l

l l

1 1

I I

I 1

ICopy Radiation Health Handbook l l

l l

l 1

1 I

I I

l l 1

ICalculator With Battery.

l l

l l

l 1

1 I

I I

l 5 lYellow Pads l

l l

l l

l l

1 1

I l

4 l Polyethylene Sheets l

1 l

l

'l i

I I

I I

l 10 11 Gallon Samole Bottles l

l l

l l

l l

l l

l l 10 155 Gallon Plastic Bags l

l l

l l

l l

l l

l l 10 lLaroe Yellow Plastic Baas l

l l

l l l l Air Sample Filter Packets l

l l

l l l 10 l(Filter, Silver Zeolite,Envelonel l

l l

1 1

I I

i 1

l 15 1200 MR Dosimeters i

I l

l l

l 1

I I

I l

1 IHigh Range Dosimeter l

l l

l l

l l

l l

1 l

1 l Dosimeter Charcer/Batt. Chance l l

l l

FORM 372 22 3643 I.. i 1

4 PUZLIC SERVICE COMPANY OF COLORADO Attach. HPP-37A 3

  • FORT ST. VRAIN NUCLE AR GENERATING STATION j

g l

PERSONNEL CONTROL CENTER INVENTORY LIST l0' AN. I ITEM IPSC WHSE.!ENG./0.A.!

REMARKS l

J l

1 I

I I

l l l 5 l Film Badoes l

l l

l l

1 1

I I

I l100 IWipe Envelopes l

l l

l 1

I i

i l

1 l l 4 l Boxes 2" Wipes l

l l

l l l 1

l l

1 1

Il 1

IBox 2" Planchetts l

l l

l l

l l

l I

l i

1 IBox Plastic Gloves l

l l

l l

1 l

l l

l l

1 IFirst Aid Kit l

l l

l I

1 1

1 I

I I 32 IBody Outline Tags l

l l

[

l i

I I

I I

l 4 12" Masking Taoe l

l l

l l

1 1

I i

l l

1 IRadiation Tape l

l l

l 1

1 I

I I

I I

5 l Warning Signs l

l l

l 1

I I

I I

l l

1 IRoll Radiation Ribbon l

l l

l l

l 1

I I

I l

2 l Road Signs l

l l

l l

l l

l 1

I l

2 l Rolls Yellow Rope l

l l

l I

I I

I I

I l l 30 ! Vials Potassium Iodide Tablets l l

l l

1 I

i 1

1 1

IDirectional Sions l

l l

l l

,l l

l 1

1 I

l 1

IScrewdriver l

l l

l 1

1 I

i I

l l l 1

lAllen Wrench 5/64" l

l l

l l

l l

l l

1 l

2 l Wrenches l

l l

l l

1 1

I I

I l

2 IFlashlights/Batt. Chance l

l l

l l

l l

1 I

I l

2 IFull Face Resoirators l

l l

l 1

1 I

I I

l l

4 ID-Cell Batteries / Chanced l

l l

l l

1 I

i l

l l

4 iTransistor Batteries / Changed l

l l

l FORM 372 22 3643

' PUZLIC SERVICE COMPANY OF COLORADO Attach. HPP-37A s e FORT ST. VRAIN NUCLE AR GENERATING STATION g

l l

l PERSONNEL CONTROL CENTER INVENTORY LIST l0UAN.!

ITEM iPSC WHSE.IENG./0.A.I REMARKS

_l l

1 I

i l

l l

1 ISoare RM-14/15 Cable I

l I

l i

I l

l l

I l

1 ISpare HP 210 Probe Detector l

l l

l l

l l

l l

I l

l 1 l Air Sampler l

l l

l l

l l

l l

l l

l 1 IRM 14/15 l

l l

l l

l l

l l

l l

1 l Ion Chamber l

I l

l l

l 1

I I

I l

1 IHP 210 Probe l

l l

l l

l l

l 1

I l

5 IComplete Sets Cloth Anti-C's l

l l

l l

l l

1 I

I l l 1

l Phone Cradle With Speakers l

l l

l 1I I

I I

I I

l l 4 IVenicle Keys (Sets) l l

l l

l l l 1

I I

I I

l l l 2 l Electric Generators l Parcel Search Room l l

1I I

I I

I I

l l 5 IScott Air Paks I

i l

l ll l

l l

l l

l l 1

l Copy of Most Recent Exp. Reportl l

l l

F OR M 372 22 - 3643

PUBLIC SERVICE COMPANY OF COLORADO Attach. HPP-37A

+

  • 8 FORT ST. VRAIN NUCLEAR GENERATING STATION I

PERSONNEL CONTROL CENTER INVENTORY LIST 100AN.I ITEM IPSC WHSE. LEI'3./0.A.I REMARKS l

1 I

l l Drum Decon Supolies and Anti-C's (To Be Checked If Seal Is Broken l l

l 1

I I

I l 75 l Anti-C Coveralls - Paper l

l l

l l

1 1

1 1

I l 75 IPairs Shoe Covers - Pacer l

l l

l l

l 1

1 I

I l 75 IPairs Gloves - Cotton l

1 l

l 1

I I

I I

l l 50 l Pairs Gloves - Vinyl l

l l

l l

1 1

I I

I l100 ICotton Balls l

l l

1 1

I I

I i

l300 1D1sposable Pacer Towels l-l l

l l

l 1

l I

I 1100 10-Tips l

l l

l I

I I

I I

I

-l 25 lurine Sample Bottles l

l l

l l

l l

1 I

I l.5 IGallon De-Con Soao

~

l l

l l

l l

l l

l 1

-l 2 ICans Waterless Hand Cleaner l

l l

l 1

1 I

I I

I l

2 lLarge Poly Bags l

l l

l l

l 1

1 I

I l

4 ISmall Yellow Poly Bags l

l l

l 1

1 I

I I

I l

2 IRolls Masking Tape l

l l

l l

1 I

I I

I l

1 IRoll Radiation Tape l

l l

l

~l l

I I

I I

l 50 IWipe Envelopes l

l l

l l

1 FORM 372 22 3643

r g

PUBLIC SERVICE COMPANY OF COLORADO Attach. HPP-373 e

FORT ST. VRAIN NUCLEAR GENER ATING STATION l

EAB, EPZ SURVEY TEAM INVENTORY LIST lQUAN.I ITEM iEAB iEPZ j

REMARKS I

l IFIELD KITIFIELD KITI i

l 1

I I

i I

l 1

ISAM II Scaler, Shield l

l l

1 I

I i

l l

l l

1 IPIC-6A or Ecuivalent i

I i

i l

l l

l l

1 l

1 iRM-14/15 w/HP-210 Probe l

l l

l l

1 I

I I

I l

1 IRadeco Air Samoler l

l l

l l

10 l Air Sample Packets i

I l

l l

f(Filter, Silver Zeolite, Env.) l I

i i

l I

i l

i I

l 1

IBox 2" Wipes l

l l

l 1

I I

I I

I l 50 l Wipe Envelopes i

l l

l 1

I I

I I

I l

1 l Calculator w/ Battery l

l l

l l

I I

l l

l 1

1 IStopwatch l

l l

l l

l 1

1 I

I l

1 l Roll Radiation Taoe l

l l

l l

l l

l l

l l

1 IBox Plastic Gloves

[

]

l l

l l

I I

I I

l 1

lFlashlicht w/ Batteries l

l l

l 1

1 I

I I

I l

1 l Set Of Maos l

l l

1 1

I i

1 1

I i

1 IClipboard l

l l

l l

l I

I I

I l

1 l Tablet Of Paper l

l l

l l

l l

l l

l l

1 l Loo Book

[

]

l l

l 1

1 I

I I

'l 1

l Procedure (RERP-FIELD) l l

l l

l l

l l

1 i

l 2 l Black Pens l

l l

l l

1 1

I I

I l

2 l Red Pens l

l l

l 1

1 I

I I

i l

1 l Compass l

l l

l l

l l

l l

l l

2 l Pencils l

l l

l P O R M 372 22 3643

PUBLIC SERVICE COMPANY OF COLORADO Attach. HPP-37C FORT ST. VRAIN NUCLEAR GENERATING STATION f7 l

TECHNICAL SUPPORT CENTER INVENTORY LIST lQUAN.l ITEM l

TECHNICAL j

REMARKS l

l l

l SUPPORT CENTER!

l l

1 I

l l

1 2

IBoxes 100 Wines Each

[

l l

I I

I I

I l

1 -IPackage Masslin Cloth l

l

[

l i

I I

i l

1 l Roll Radiation P.ibbon

[

l l

l l Scott Full Face Respirators l

l l

l 2

Iwith 2 Canisters l

l l

l l

l l

l 1 15 IFull Set of Anti-C's l

l l

l 1

I I

I l

9 10-200 MR Dosimeters l

l l

l l

l l

l l

2 l Bars Soap l

l l

l l

l 1

I l

1 1 Dosimeter Charger l

l l

1 I

l l

l

(

l 1

lRM-14 l

[

[

l i

i l

I l

1 ICoaxial Cable

[

[

l 1

I I

I I

l 1

lHP-210 Probe l

l l

l l

1 l

l l

1 ISet Survey Maps l

l l

l l

l l

l l

5 IScott Air Paks l

l l

l l l

l l

l l l 20 IVials Potassium Iodide Tablets [

l l

FORM 372-22 3643

c.

t PUBLIC SERVICE COMPANY OF COLORADO Aggach. HPP-37D FORT ST. VRAIN NUCLEAR GENERATING STATION ssue l

HEALTH PHYSICS AREA EMERGENCY SUPPLIES lQUAN.1 ITEM i

LOCATION REMARKS l

l l

l l

1 l

1200 MR Dosimeters

_]

I l

i I

I I

I l

lHioh Rance Dosimeters l

l l

l l

l l

l l

l Survey Meters (Dose Rate) l l

l 1

1 I

I I

l l Survey Meters (Contamination) l l

1 I

I I

I l 100 lAnti-Contamination Clothino l

-l l

l 1

1 I

I l

4 IScott Air Paks l

I l

1 1

I I

I l

5 lSoare Bottles l

l l

1 I

I I

I I

IFFR l

l l

l l

1 1

I l

l Cartridges (Spare) l l

l l

l l

l l

l l Air Samplers l

l l

l 1

I I

I l

2 IFlashlights l

l l

1 I

I I

I l

l Batteries l

l l

l l

1 I

I l

l Flashlight Bulbs l

l l

l l

1 I

I l

l Poly Bags l

l l

l 1

1 I

I l

l Masking Tape l

l l

l l

I I

I l

l Survey Maps

[

l l

'l I

I 1

l l Clipboard l

l l

1 I

I I

I l

l Pencils l

l l

l l

l l

l l

l Chalk l

l l

1 1

I I

I l

l Radiation Warnino Sions l

l l

l l

l l

l l

l Barrier Tape l

l l

l l

1 1

I l

lWiDes l

l l

l l

1 1

I I

IEnvelopes l

l l

FORM 372 22 3643

r 1

PUBLIC SERVICE COMPANY OF COLORADO Attach. HPP-37E Issue 15 FORT ST VRAIN NUCLEAR GENERATING STATION s

Page 1 of 1 l

CONTROL ROOM EMERGENCY SUPPLIES lQUAN.i ITEM LOCATION f

REMARKS l

1 1

I I

I l

5 ! Scott Air Paks l

CR l

l l

1 l

l l

l 3 lair Line Respirators l

CR l

l 1

1 I

I I

l 8 1200 MR Dosimeter l

CR l

l l

l l

l-l l

2 lHigh Range Dosimeters l

CR l

l n

l i

i FORM 372 22 3643 I

r PUBLIC SERVICE COMPANY OF COLORADO Attach. HPF-37F

=

s e FORT ST. VRAIN NUCLEAR GENERATING STATION l

DECON AREA EQUIPMENT SUPPLIES 10UAN.!

ITEM i

LOCATION REMARKS l

l 5

l l

l l

l Sets IAnti-C's Pacer l

l l

l 1

I I

I l

IBANDAGES:

l l

l l

1 -l l

I I

l Box I 4" x 5 YDS l

l l

l 8 I I

I I

lBoxest 3" x 3" l

l l

l 1

i i

I l

l Box l 8" x 10" l

l l

l l

I l

I l

l BAGS l

l l

l I

I I

I l

4 i Clear l

l l

l l

I l

I l 10 l

Yellow l

l l

l l

l l

l l

1 l Cloth Sheets J

l l

1 1

I I

I l

1 ICloth Blankets l

l l

l 1

l l

l l

l Bag ICotton Balls l

l l

l l

l l

l l

4 l Eye Lotion l

l l

l l

1 I

I l

1 lEye Cup l

l l

l 1

1 I

I l

1 IEye Wash l

l l

l l

1 1

I

.l 4

l Film Badoes l

l l

l l

l l

l l

4 lFirst Aid Blankets l

l l

'l l

I I

I l

1 IFirst t.id Kit - Larce l

l l

l 1

I I

I l

1 IFirst Aid Kit - Small l

l l

i F OR M 372 3643

r 1

PUBLIC SERVICE COMPANY OF COLORADO Attach. HPD-37F

.e 8

y FORT ST, VRAIN NUCLEAR GENERATING STATION l

DECON AREA EQUIPMENT SUPPLIES lQUAN.1 ITEM i

LOCATION I

REMARKS l

l l-1 I

l l

IGLOVES:

l l

l l

2 1 1

I I

l Pairl Rubber i

l l

l 4 I I

I I

lBoxest Plastic l

l l

l 1

I I

I I

4 IPens I

I I

1 1 I

I I

lBttle! Pot. Permanaanate 1

l l

12 i I

l l Boxes l0-Tips l

l l

1 1

1 I

I I

l Box ITide l

l l

l 1

I I

I I

lBttlelAES-700 l

l l

l 1 1 I

I I

,lBttlelSodium Sulfite l

l 1

l l

l l

l l 100 IBody Outline Tags

-l l

l l

l l

l l

l 1 l Gray Tape

- l-l l

l l

l l

1 l

4 l Masking Tape l

l l

1 1

I I

I l

2 IRadiation Warning Tape l

l l

l 1 I I

I I

lBttlel Titanium Dioxide l

l l

l 2 I I

I I

lPacksITowels - Disposable l

l l

l l

l 1

l l 400 IWipes l

l l

'l i

I I

I l 100 IWipe Envelopes l

l l

FORM 372 22 3643

PUBLIC SERVICE COMPANY OF COLORADO Attach. HPP-37G 8 I FORT ST. VRAIN NUCLEAR GENERATING STATION l

EMERGENCY RESPIRATORY PROTECTIVE EQUIPMENT l0UAN.I ITEM I

LOCATION I

REMARKS l

l I

i i

I l

5 IScott Air Pak l Search & I.D. Bldo.l l

l 1

I I

I l

2 l Scott Air Pak lCAS l

l l

l lEl. 4829 (Outside l l

l 2 IScott Air Pak

[ Control Room) l l

l l

lEl. 4811 (Outside I l

l 2

! Scott Air Pak l Aux. Elec. Room) l l

l l

lEl. 4791 (Outside l l

l 2

IScott Air Pak l480V Room) l l

l 1

l El. 4791 (Outside l

l l

2 IScott Air Pak lFirst Aid Room) l

[

l l

I l

1 l

1 IScot: Air Pak

-l Chemical Buildina l

l ad e

D F O R M 372 mM3

1

~

PUBLIC SERVICE COMPANY OF COLORADO Attach. HPP-37H Issue 15 FORT ST. VRAIN NUCLEAR GENERATING STATION Page 1 of 1 INSPECTIDN RESULTS INSPECTED BY DATE Discrepancies Found:

Discrepancies Corrected By:

Date Reviewed By:

Date Health Physicist FORM 372 22 3643