ML20071L242

From kanterella
Jump to navigation Jump to search
Second Interim Deficiency Rept Re Nonconforming Matl Utilized by Wkm Valve Div of AIF Industries in Mfg Decay Heat Removal Sys Valves.Initially Reported on 820503.Next Rept Will Be Submitted by 820831
ML20071L242
Person / Time
Site: Bellefonte  Tennessee Valley Authority icon.png
Issue date: 07/19/1982
From: Mills L
TENNESSEE VALLEY AUTHORITY
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
10CFR-050.55E, 10CFR-50.55E, NUDOCS 8208020380
Download: ML20071L242 (2)


Text

.

/

i*

TENNESSEE VALLEY AUTHORITY, CHATTANOOGA. TENNESSEE 374ot

[!

400 Chestnut Street Tower II TO 3

7t" July 19, 1982 N

OS BLRD-50-438/82-36 BLRD-50-439/82-33 N

c3 U.S. Nuclear Regulatory Commission c

Region II Attn:

Mr. James P. O'Reilly, Regional Administrator 101 Marietta Street, Suite 3100 Atlanta, Georgia 30303

Dear Mr. O'Reilly:

BELLEFONTE NUCLEAR PLANT UNITS 1 AND 2 - NONCONFORMING MATERIAL USED BY WKM IN DECAY HEAT REMOVAL VALVES - BLRD-50-438/82-36, BLRD-50-439/82 SECOND INTERIM REPORT The subject deficiency was initially reported to NRC-0IE Inspector Don Quick on May 3, 1982 in accordance with 10 CFR 50.55(e) as NCR BLN NEB 8207. This was followed by our first interim report dated June 2, 1982. Enclosed is our second interim report. We expect to submit our next report by August 31, 1982.

If you have any questions concerning this matter, please get in touch with R. H. Shell at FTS 858-2688.

Very truly yours, TENNESSEE VALLEY AUTHORITY L. M.' Mills, M ager Nuclear Licensing Enclosure cc:

Mr. Richard C. DeYoung, Director (Enclosure)

Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington, DC 20555-Mr. James McFarland (Enclosure)

Senior Project Manager Babcock & Wilcox Company P.O. Box 1260 Lynchburg, Virginia 24505

(

M8,!

%. t 'fg4. <,,,nj 3"d' b[

8208020380 820719 PDR ADOCK 05000438 S

PDR An Equal Opportunity Employer m_

e ENCLOSURE BELLEFONTE NUCLEAR PLANT UNITS 1 AND 2 F

NONCONFTRMING MATERIAL USED BY WKM IN DECAY HEAT REMOVAL VALVES 10 CFR 50.55(e)

NCR BLN NEB 8207 BLRD-50-43 8/ 82-36, BLRD-50-439/ 82-33 SECOND INTERIM REPORT k

Descrintion of Deficiency Babcock 8.Wilcox (B8W) has recently found that nonconforming material was utilized by WKM Valve Division, AIF Industries, Houston, Texas, in the manuf acture of some Decay Heat Removal System (DHR) valves.

Carbon steel was utilized instead of stainless steel for the stem to disk pin.

Since the situation has occurred in -more than one valve, B6W is investigating the need for inspection of all WDI valves of this design. This information was transmitted to TVA via B8W 1etter D-4072, and the subsequent NCR was written. Bellefonte unit 1 DUR valves IDH-HV3A and IDH-HV3B and unit 2 valves 2DH-HV3A and 2DH-HV3B were manuf actured by WKM of this design. The unit i valves are installed, while the unit 2 valves are presently at WDI for repairs necesritated in regard to NCRs BLN NEB 8002,1315, and 1316, which were previously reported under 10 CFR 50.55(e). Bellefonte is the only "IVA plant utilizing WKM valves.

Interim Progress Babcock 8 Wilcox has not yet supplied 'IVA with the results of their investigation. Upon receipt of these results and depending upon the outcome of B8W's investigation, 'IVA will then determine any corrective actions.