Proposed Tech Spec Table 6.2-1 Re Operator License Requirements & Min Shift Crew Composition
ML20070F287
Person / Time
Site: Davis Besse 
Issue date: 03/01/1991
From:
CENTERIOR ENERGY
To:
Shared Package
ML20070F275 List:
References
NUDOCS 9103080221
Download: ML20070F287 (2)


Text

Osekot Nu:bar 50-346 Licens2 Nunbar NPF-3 Serici Hu:Ler 1903

[, h)) %]

Attachm:nt Page 6 I

6. 0 ADMINISTRATIVE CONTROLS 6.2.2 TACILITY STAFF a.

Each on duty shif t shall be composed of at least the minimum shift crew composition shown in Table 6.2-1.

b.

At least one licensed Operator shall be in the control panel area when fuel is in the reactor.

c.

At least two licensed Operators, one of which has a Senior Reactor Operator license, shall be present in the control room while in MODES 1, 2, 3, or 4 d.

An individual qualified in radiation protection procedures a

shall be on site when fuel is in the reactor #,

e.

All CORE ALTERATIONS shall be directly supervised by either a licensed Senior Reactor Operator or Senior Reactor Operator Limited to Fuel Handling who has no other concurrent responsi-bilities during this operation.

f.

A site Fire Brigade of at least 5 members shall be mainteined onsite at all timest.

The Fire Brigade shall not include 3 members of the minimum shif t crew necessary for saf e shutdown of the unit and any personnel required for other essentiel functions during a fire emergency.

g.

The Manager-plant Operations shall either hold or have held a senior reactor operator's license on a pressurized water reactor.

The Operations Superintendent shall hold a senior I

reactor operator license for the Cavis-Besse Nuclear Power Station.

i e

  1. The individual qualified in radiation protection procedures dnd the Fire Brigade Composition may be less than the minimum requirements for a period of time not to exceed 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> in order to accommodate unexpected absence, provided inmediate action is taken to fill the required positions.

9103080221 910301 PDR ADOCK 05000346 P

PDR DAVIS-BESSE, UNIT 1 6 la Amendment No. 7,1B,98,115.135,237 (next page is 6-2) 142

(

Docket Numb:r 50-346

  • Licens) Nunbar NPF-3 Ssrtal Nunbar 1903 a

Attachm:nt Page 7 TABLE 6.2-1 MINIMUM SHIFT CREV COMPOSITIONI LICENSE APPLICABLE H0 DES CATECORY 1

2, 3 & 4 1&6 SOL 2H*

1*

OL 2

1 Non-Licensed 2

1 Shift Technical Advisor 1*H None Required

  • Does not include the licensed Senior Reactor Operator or Senior Reactor Operator Limited to Fuel Handling supervising CORE ALTERATIONS.

tShift crew composition may be less than the minimum requirements for a period of time not to exceed 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> in order to accommouate unexpected absence of on duty shift crev members provided immediate act!7n is taken to restore the shift crev composition to vithin the minimum requirements of Table 6.2 1.

___, - ~ ~

' ^

-m N w N.

m rMOne of the two required individuals filling the SOL positions may also assume the STA function provided the individual meets the

\\

qualifications for the combined SRO/STA position specified for Option 1

)

of the Commission's Policy Statement on Engineering Exportise on Shift. If this option is used for a shift, then the separate STA position may be eliminated for that shift.

7.-

,h /

yN 1

AmendmentNo.[,137 DAVIS-BESSE, UNIT 1 6-4