ML20069J977

From kanterella
Jump to navigation Jump to search
Corrected TS Page 3/4 3-13,reflecting Deletion of Steam/Fw Flow Mismatch
ML20069J977
Person / Time
Site: Farley 
Issue date: 06/09/1994
From:
SOUTHERN NUCLEAR OPERATING CO.
To:
Shared Package
ML20069J971 List:
References
NUDOCS 9406150200
Download: ML20069J977 (1)


Text

.

TABLE 4.3-1 (Continued)

REACTOR TRIP SYSTEM INSTRUMENTATION SURVEILLANCE REOUIREMENTS CHANNEL MODES IN WHICH y

CHANNEL CHANNEL FUNCTIONAL SURVEILLANCE o

FUNTIONAL UNIT CHECK CALIBRATION TEST REOUIRED n

~

'TT4<

13.

Steam Generator Water S

R Q

1, 2

l Level--Low-Low 3G l 14.

Steam /Feedwater Flow S

P Q

1, 2 l

Coo Mismatch and Low Steam OS Generator Water Level

  • XO om 15.

Undervoltage -_ Reactor N.A.

R Q

l l

gg Coolant Pumps om 1

. y$$

16.

Underfrequency - Reactor N.A.

R Q

l l

x&

Coolant Pumps 4

17.

Turbine Trip A.

Low Auto Stop Oil Pressure N.A R

S/U ( 9 ) (10 )

N.A.

B.

Turbine Throttle Valve N.A R

S/U(9)(10)

N.A.

w Closure s

18.

Safety Injection Input from ESF N.A.

N.A.

R(4) 1, 2

l ww 19.

Reactor Coolant Pump Breaker N.A.

N.A.

R 1

Position Trip 20.

Reactor Trip System Interlocks N.A.

R S/U(8) 1 21.

Reactor Trip Breaker N.A.

N.A.

M (5 ) (14 ) (15),

1, 2,

S /U (1) (14 ) (15 )

3*,

4*,

5*

22.

Automatic Trip Logic N.A.

N.A.

M(5) 1, 2,

3*,

4*,

5*

Eg 23.

Reactor Trip Bypass Breaker N.A.

N.A.

(13),R(11) 1, 2,

p 3*,

4*,

5*

-4 Deletion of this functional trip shall be implemented prior to go startup from refueling outage 12.

e e--

+r-,.

-