Letter Sequence Request |
|---|
|
|
MONTHYEARML20069H9101982-09-17017 September 1982 Application for Emergency Change to Tech Spec Table 4.3-11, Extending Steam Line Pressure - Low Switch Surveillance Period by 96-h,until Midnight 820916.Safety Evaluation Encl Project stage: Request ML20069H9131982-09-17017 September 1982 Proposed Change to Tech Spec Table 4.3-11,extending Steam Line Pressure - Low Switch Surveillance Period by 96-h,until Midnight 820916 Project stage: Request 05000346/LER-1982-044, Forwards LER 82-044/03L-01982-09-30030 September 1982 Forwards LER 82-044/03L-0 Project stage: Other ML20063N6731982-09-30030 September 1982 Application to Amend License NPF-3,revising Tech Spec Table 4.3-11 Re Steam & Feedwater Rupture Control Sys Instrumentation Surveillance Requirements Project stage: Request ML20063N6711982-09-30030 September 1982 Forwards Application to Amend License NPF-3,revising Tech Spec Table 4.3-11 Re Steam & Feedwater Rupture Control Sys Instrumentation Surveillance Requirements Project stage: Request 05000346/LER-1982-044-03, /03L-0:on 820916,review Revealed That Steam & Feedwater Rupture Control Sys Monthly Surveillance Procedure ST 5031.14 Not Completed in Time Allotted in Tech Specs. Caused by Personnel Error.Test Completed1982-09-30030 September 1982 /03L-0:on 820916,review Revealed That Steam & Feedwater Rupture Control Sys Monthly Surveillance Procedure ST 5031.14 Not Completed in Time Allotted in Tech Specs. Caused by Personnel Error.Test Completed Project stage: Other ML20063N6761982-09-30030 September 1982 Proposed Revision to Tech Spec Table 4.3-11 Re Steam & Feedwater Rupture Control Sys Instrumentation Surveillance Requirements.Safety Evaluation Encl Project stage: Other 1982-09-17
[Table View] |
Proposed Change to Tech Spec Table 4.3-11,extending Steam Line Pressure - Low Switch Surveillance Period by 96-h,until Midnight 820916| ML20069H913 |
| Person / Time |
|---|
| Site: |
Davis Besse  |
|---|
| Issue date: |
09/17/1982 |
|---|
| From: |
TOLEDO EDISON CO. |
|---|
| To: |
|
|---|
| Shared Package |
|---|
| ML20069H901 |
List: |
|---|
| References |
|---|
| TAC-48816, NUDOCS 8210210559 |
| Download: ML20069H913 (1) |
|
Text
{_
t J
~ Blikt g
R u
i anga i
c m
m futmE l
l4WT 081 ElW111t 15T
~
- 1. 1stmustGemsi
- a. Steella FranPs-les 5
t M+
j
- b. Ste m fe a reter l a el. l m l'
R l
i
- c. StanImeretr feedeler 5
t X
Mfforatial Prenere af$
- d. Sector Colut Paps 4em of 3
i X
w l
h
- 2. h a ul Actuett u R
R t*
'l I
CO l
in-i is traim hiw en
- ig. -
,3 brd 31,1982.
gay z!! ;j, d
d
+ h Summace Parted fa sessa lins Passers - tm 6 h exanded by % ho
- k to ed at 2@ hours ca 9/16/82.
j; 0$
l
?
l 8210210559 820920
~~
L PDR ADOCK 05000346 PDR p
ee--ew--,-w