ML20069F687

From kanterella
Jump to navigation Jump to search

Application for Amend to License DPR-24,proposing Tech Spec Change 85 to Encompass Addl Limitations on Plant Operations Assuming Reduced RCS Flow W/Sufficient Steam Generator Tube Plugging.Class III Amend Fee Encl
ML20069F687
Person / Time
Site: Point Beach NextEra Energy icon.png
Issue date: 09/17/1982
From: Fay C
WISCONSIN ELECTRIC POWER CO.
To: Harold Denton
Office of Nuclear Reactor Regulation
Shared Package
ML20069F691 List:
References
TAC-48853, TAC-48938, NUDOCS 8209280203
Download: ML20069F687 (3)


Text

A Msconsin Electrwrow coww 231 E MICHIGAN, P.O. BOX 2046. MILWAUKEE, WI 53201 September 17, 1982 CERTIFIED MAIL Mr. H. R. Denton, Director Office of Nuclear Reactor Regulation U. S. NUCLEAR REGULATORY COMMISSION Washington, D. C. 20555

Dear Mr. Denton:

DOCKET NO. 50-266 TECHNICAL SPECIFICATION CHANGE REQUEST NO. 85 SPECIFICATION FOR REDUCED THERMAL DESIGN FLOW POINT BEACH NUCLEAR PLANT, UNIT 1 In accordance with the requirements of 10 CFR Part 50.59, Wisconsin Electric Power Company (Licensee) hereby submits its application for an amendment to Facility Operating License DPR-24 for the Point Beach Nuclear Plant, Unit 1. The purpose of this amendment is to incorporate certain changes and revisions into the Technical Specifications.

The proposed changes to the Technical Specifications encompass additional limitations on plant operations assuming a reduced reactor coolant system (RCS) flow such as may occur if a sufficient number of steam generator tubes are plugged. The current Technical Specifications and the original safety analyses, as discussed in the Point Beach Final Safety Analysis Report (FSAR),

are based on a minimum thermal design flow (TDF) of 178,000 gpm.

Additional analyses have been completed for a revised minimum flow of 169,000 gpm, or 95% of the present TDF. This is the predicted RCS flow given 24% of the steam generator tubes plugged. Attachment A to this letter presents the results of the non-LOCA analyses performed to support this license amendment. These analyses have also resulted in a number of changes to the Technical Specifications.

The specific changes are discussed as follows:

1. The principal change accompanying this analysis is a new definition in Section 15.1 for the term full power. Full power is defined as 100S of rated power when the RCS total flow is greater than 178,000 gpm and 91% of rated power when the RCS total flow is less than 178,000 gpm. As defined in Specification 15.3.1.G.3, the minimum RCS total flow rate must be greater than or equal to 95% of 178,000 gpm. In various locations hyd hg 0gg

~~

^

0209280203 B20917 DR ADOCK 05000266 PDR h Q g\

Mr. H. R. Denton September 17, 1982 throughout the Technical Specifications the term full power, as defined in 15.1, is used to replace the term rated' power. These changes are identified by margin bars on the attached proposed Technical Specification pages.

2. Specification 15.2.1 is revised to include a new Figure 15.2.1-2, " Core DNB Safety Limits", for the situation when RCS total flow is less than 178,000 gpm.
3. Specification 15.3.1.G is revised to specify a maximum Tavg for the condition of RCS total flow less than 178,000 gpm and to specify the revised minimum TDF of .95 x 178,000 as supported by the attached analyses.
4. Specification 15.3.10.B.1, " Power Distribution Limits",

has been revised to specify the maximum hot channel factors for the conditions of RCS total flow both greater than and less than 178,000 gpm.

The current LOCA analysis as filed with the NPC for Point Beach Nuclear Plant Unit 1 assumed 100% of rated power, a minimum TDF of 178,000 gpm, and up to 18% of the steam generator tubes plugged. This evaluation resulted in a peak clad temperature (PCT) of 2062'F at an FO of 2.32. Calculations have been performed to estimate results for the plant conditions of 91% rated power, 95% of 178,000 gpm RCS total flow, and 24% of the steam generator tubes plugged. The results of these calcula-tions indicated that the Point Beach units would have an estimated PCT of 2128'F at an Fo of 2.52 which still provides an acceptable margin to the applicable 10 CFR Part 50 Appendix K-limits.

The proposed operating condition of 91% rated power and 24% steam generator tubes plugged was also examined in consideration of the thermal hydraulic performance of the Point Beach steam generators. We concluded that these revised conditions would be acceptable for moisture carryover, primary tube erosion, and stability considerations. Furthermore, the operating experience with Westinghouse steam generators at other facilities having significant levels of tube plugging of from 15 to 30% have demonstrated no indications that plugging-related bundle flow modifications have affected the steam generator performance.

b Mr. H. R. Denton September 17, 1982 In accordance with the schedule of amendment approval fees for reactor facility licenses as listed in 10 CFR Part 170.22, Licensee has determined that this license amendment approval for Point Beach Unit 1 should be classified as a Class III amendment. This classification is based on the premise that this change request encompasses a single safety issue which does not involve a significant hazards consideration. Furthermore, we believe that acceptability of this issue, that is authorization for operation at a reduced RCS flow, has previously been reviewed and approved by the NRC in other dockets. Accordingly, we have enclosed a check in the amount of $4,000 as payment for the applicable Class III license amendment approval fee.

As further specified in the Commission's regulations, we enclose herewith three signed originals and 40 additional copies of this license amendment application with attachments.

Please contact Licensee if you have any questions concerning this submittal.

Very truly yours, 7

Assistant V c - resident C. W. Fay Enclosures (Check No. 693502)

Copy to NRC Resident Inspector Subscribed and sworn to before me this sot 6 day of September 1982.

WY ~

Ndtary Puq41c, State of Wisconsin My Commission expires v jujd /,)(3f.

Gr

- - - -