Proposed Tech Specs,Increasing Number of Senior Reactor Operators Required to Be on Duty & Replacing Ref in Tech Spec 6.2.2.d W/Ref to Operations Manager for Each Respective Unit
ML20067E584
Person / Time
Site: Brunswick  
Issue date: 02/11/1991
From:
CAROLINA POWER & LIGHT CO.
To:
Shared Package
ML20067E582 List:
References
NUDOCS 9102150163
Download: ML20067E584 (14)


Text

_ - _ _ _ _ _ _ _ - _ _

ENCLOSURE $

I BRUNSWICK STEAM ELECTRIC P! ANT, UNITS 1 AND 2

.i NRC DOCKETS $0 325 & 50 324 OPERATING LICENSES DPR 71 & DPR 62 i

REQUEST FOR LICENSC AMENDMENT OPERATIONS ORGANIZATION CHANGES TECHNICAL SPECIFICATION PAGES. UNIT 1 t

+

l l

9102150163 910211

~

PDR ADOCK 05000324 P-PDR

i ADMIWiS1K!*IVE t0NTROLS wu

)

s FACILITY STAFF (Continued)

O u.ttons Man T.he.p;f; ^e;reti.,;ger - unit t q

c-;;ri:::;. Shift Foremen, and Senior Control d.

Operators;shall hold a senior reactor operator license. The Control Operators shall hold a reactor operator license.

IN6sRT ( aktached) f p'.

An individual qualified to implement radiation protection procedures

[

t shall be onsir.e when fuel is in either reactor.*

i

/

All CORE. ALTERATIONS shall be directly supervised by either a.

l b.

licensed Senior Reactor Operator or Senior Reactor Operator Limited to Fuel Handling who has no other concurrent responsibilities during

(

this operation.

l 5

h'pf.

A; Fire Brigade of at least five members shall be maintained onsite at I

all times.*.The Fire Brigade shall not include the minimum shift crew shown in Table 6.2.2-1 or any personnel required for other.

essential funcs. ns during a fire emergency.

L )(.*

Administrative procedur developed and implemented to limit j

i the working. hours of 6

., wno perform safety-related

'functionst e.g.,-ser,-

eactor op3rators, reactor operators, health.

. physicists -auxiliary operators, and key maintenance personnel.

These procedures =shal1~ meet the working hour guidelines published by:

[

the Commission in Cenoric Letter No. 82-12.-

t

?

t il

(

l T

P I

i i

i i

' *'The individualfqualified to' implement radiation protection procedures and Fire' Brigade composition may be:less than the' minimum requirements for a

-period-of-time not to exceed two hours in order to accommodate unexpected F

absence provided immediate' action is taken to fill the required positions.

l; lNSt.RT (adac.heb L

. BRUNSWICK - UNIT 1 6-2 Amendment No. 138 1

l.;

r

!).

___,,,_.,_,;_.-,__,a_,,

.,...-..--_..,,___.-a_

I Insert for Technical Specification 6.2.2:

e.

The Manager + Operations shall hold or have held a senior reactor operators license for either the Brunswick Plant or a similar plant.(a)

Insert for Footnote (a):

(a) The requirement for the Manager. Operations to hold or have held a senior reactor operator license is exempted for a period of 18 months starting from (the date of amendment issusnee).

t 2

P

[

o 4

L b

1 9

3 TABLE 6.2.2-1 MINIMUM FACILITY SHIFT CREW COMPOSITION WITH UNIT 2 IN CONDITION 1, 2, OR 3 POSITION NUMBER OF INDIVIDUALS REQUIRED TO FILL POSITION CONDITIONS 1, 2, & 3 CONDITIONS 4 & 5

_mmo

.(h)

SR (a) gj.

g pb)

RO "}

3 3

A0 3

3 STA 1

1 l

WITH UNIT 2 IN CONDITION 4 OR 5 POSITION NUMBER OF INDIVIDUALS REQUIRED TO FILL POSITION CONDITIONS 1, 2, & 3 CONDITIONS 4 & 5 i[b) mmo S{(a) gh gpb)

RO a)

. 3 2

A0 3

STA 1

None WITH UNIT 2 DE-FUELED POSITION NUMBER OF INDIVIDUALS REQUIRED TO FILL POSITION CONDITIONS 1, 2, & 3 CONDITIONS 4 & 5

~

, [ 5L

,, m m g{(a) g.h be 2

RO a) 2 2

AO 3

3 STA 1

None BRUNSWICK - UNIT 1 6-3 Amendment No. 138

l a

A TABLE 6.2.2-1 (Continued)

MINIMUM FACILITY SHIFT CREW COMP 0SITION i

TABLE NOTATION

-COC - Chif: Opero:ir.g C.p J ::- u i :-h-: 5:r!:: Re::te: Oper:ter Licene:

SRO - Individual with a Senior Reactor Operators License i

RO - Individual with a Reactor Operators License I

AO - Auxiliary Operator (non-Licensed individual) l STA - Shift Technical Advisor (a) Assumes each individual is licensed on both plants.

(b) Does not include the licensed Senior Reactor Operator or Senior Reactor Operator Limited to Fuel Handling, supervising CORE ALTERATIONS.

The Shift Crew Composition may be less than the minimum requirements for a period of time not to exceed 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> in order to accommodate unexpected absence of on-duty shift crew members provided immediate action is taken to restore the Shift Crew Composition to within the minimum requirements of Table 6.2.2-1.

1 i

BRUNSWICK - UNIT 1 6-4 Amendment No.138 l

I ADMINISTRATIVE CONTROLS 6.2.3 ONSITE NUCLEAR SAFETY (ONS)

FUNCTION 6.2.3.1 The ONS Unit shall function to examine facility operating characteristics, NRC issues, industry advisories, and other sources which m y indicate areas for improving facility safety.

RESP 0NSIBILITIES 6.2.3.2 The ONS Unit shall be responsible for maintaining surveillance of facility activities to provide independent verification

  • that these activities are performed correctly and that human errors are reduced as much as practical.

AUTHORITY 6.2.3.3 The ONS Unit shall make detailed recommendations for revised procedures, equipment modifications, or other means of improving facility safety to the Manager - Corporate Nuclear Safety Section.

6.2.4 SHIFT TECHNICAL ADVISOR r Shift Foremon 6.2.4.1 The Shift Technical Advisor shall serve in an advisory capacity to the Chif: OpEvetini; Spee*4+w on matters pertaining to the engineering aspects assuring safe operation of the unit.

{3 FACILITY STAFF QUALIFICATION 6.3.1 Each member of the facility staff shall meet or exceed the minimum qualifications of ANSI N18.1-1971 for comparable positions, except for (1) the Manager

  • Environmental & Radiation Control who shall meet or exceed the qualifications of Regulatory Guide 1.8 September 1975 and (2) the Shift Technical Advisor who shall have a bachtlor's degree or equivalent in a scientific or engineering discipline with specific training in plant design, and response and analysis of the plant during transients and accidents.

6.4 TRAINING 6.4.1 A retraining and replacement training program for the facility staff shall be maintained under the direction oC the Manager - Training (BSEP) and shall meet or exceed the requirements and recommendations of Section 5.5 of ANSI N18.1-1971 and Appendix "A" of 10 CFR Part 55.

6.4.2 A training program for the Fire Brigacie shall be maintained under the direction of the Manager - Training (BSEP) and shall meet or exceed the requirements of Section 27 of the NFPA Code-1975.

  • Not responsible for sign-off function.

l 3NSERT (altoc.hech BRUNSWICK - UNIT 1 6-5 Amendmert No. 138 a

m______________._________.____.____._____________________._________

m

4 Insert for Footnote (a):

(a) The requirement for the Manager Operations to holo or have held a senior reactor operator license is exempted for a period of 18 months starting from (the date of amendment issuance).

3 i

l

=

4--

m ya

ENC 1hSURE 6 BRUNSk'ICK STIM ELECTRIC PLANT, UNITS 1 AND 2 NRC DOCKETS 50 325 6 50 324 OPERATING LICENSES DPR 71 6 DPR 62 REQUEST l'OR LICENSE AMENDMENT OPERATIONS ORGANIZATION CilANGES TECilNICAL SPECII'ICATIO,F PACI'S - l' NIT 2 6

i ADMINISTRATIVE CONTROLS FACILITY STAFF (Continued)

O The ',perauons Manager -ling 2.

..i f t Og sating S p; m :::, Shift Foremen, and Senior Control d.

Operators shall hold a senior reactor operator license.

The Control O g ators shall hold a reactor operator license.

INSE.RT (atioched )

f /.

An individual qualified to implement radiation protection procedures shall be onsite when fuel is in either reactor.*

/.

All CORE ALTERATIONS shall be directly supervised by either a licensed Senior Reactor Operator or Senior Reactor Operator Limited to Fuel Handling who has no other concurrent responsibilities during this operation.

hg A Fire Brigade of at least five members shall be maintained onsite at all times.* The Fire Brigade shall not include the minimum shift crew shown in Table 6.2.2-1 or any personnel required for other essential functions during a fire emergency.

b/

Administrative procedures shall be developed and implemented to limit the working hours of facility staff who perform safety-related functions; e.g... senior reactor operators, reactor operators, health physicists, auxiliary operators, and key maintenance personnel.

These procedures shall meet the working hour guidelines published by the Commission in Generic Letter No. 82-12.

  • The individual qualified to implement radiation protection procedures and Fire Brigade composition may be less than the minimum requirements for a period of time not to exceed two hours in order to accommodate unexpected absence provided immediate action is taken to fill the required positions.

1 N S E' R.T (CLhkQChed)

BRUNSWICK - UNIT 2 6-2 Amendment No. 170 i

_______m

i Insert for Technical Specification 6.2.2.

e.

The Manager Operations shall hold or have held a senior reactor operatora license for either the Brunswick Plant or a similar plant (a) i Insert for Footnote (a):

-(a) The requirement for the Manager Operations to hold or have held a senior reactor operator license is exempted for a period of 18 months starting from (the d4.e of amendment issuance).

4 4

t i

N

s..

TABLE 6.2.2-1 MINIMUM FACILITY SHIFT CREW COMPOSITION WITH UNIT 1 IN CONDITION 1, 2, OR 3 POSITION NUMBER OF INDIVIDUALS REQUIRED TO FILL POSITION CONDITIONS 1, 2, & 3 CONDITIONS 4 & 5 q

,fh)

^-

I SR 2/

U(b)

RO 3

3 A0 3

3 STA 1

1 WITH UNIT 1 IN CONDITION 4 OR $

POSITION NUMBER OF INDIVIDUALS REQUIRED TO FILL POSITION CONDITIONS 1, 2, & 3 CONDITIONS 4 & $

.(h1 nam

{(a) 2.h gj(b)

S RO a) 3 2

A0 3

3 STA 1

None WITH UNIT 1 DE-FUELED POSITION NUMBER OF INDIVIDUALS REQUIRED TO FILL POSITION CONDITIONS 1, 2, & 3 CONDITIONS 4 & $

.(b) mm, R

2/

2 RO 2

2 A0 3

3 STA 1

None l'

BRUNSWICK - UNIT 2 6-3 Amendment No. 170

ts: '.. 4 TABLE 6.2.2 1 (Continued) i i

MINIMUM FACILITY SHIFT CREW COMPOS! TION

]

I TABLE NOTATION j

.......,....ir.;; ;_;; ;i::: -.;F : hvi:: S::::: ^;::::::: Li e SRO - Individual with a Senior Reactor Operators License RO - Individual with a Reactor Operators License AO - Auxiliary Operator (non-11 censed individual):

1 STA - Shift Technical Advisor (a) Assumes each individual is licensed on both plants.

.I (b) Does'not include the licensed Senior Reactor-Operator or Senior Reactor Operator. Limited to Fuel Handling, supervising CORC ALTERATIONS.-

The Shift. crew Composition may.be less than the minimum requirements for'a-period of time not to exceed'2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> in order to accommodate unexpected absence of on-duty shift crew members provided immediate action.is taken to restore the.

Shift Crew Composition to.within the minimum requirementsoof Table 6.2.2-1.-

~

k

?

n i

4

-t i

1

.I 1

-i BRUNSWICKL-UNIT 2 6-4 Amendment No.170 l

l ADMINISTRATfVE CONTROLS 6.2.3 ONSITE NUCLEAR SAFETY (ONS)

FUNCTION 6.2.3.1 The ONS Unit shall function to examine facility operating characteristics, NRC issues, industry advisories, and other sources which may indicate areas for improving facility safety.

RESPONSIBILITIES 6.2.3.2 The ONS Unit shall be responelble for maintaining surveillance of facility activities to provide independent verification

  • that these activities are parformed correctly and that human errors are reduced as much as practical.

AUTHORITY 6.2.3.3 The ONS Unit shall=make detailed recommendations for revised procedures, equipment modifications, or othcr means of improving facility safety to the Manager - Corporate Nuclear Safety Section.

6.2.4 SHIFT TECHNICAL ADVISOR Shttt Fcireman 6.2.4.1,(The Shift Technical Advisor shall serve in an advisory capacity to the

-Ohif t ^[dr.tir.; Swperei::: on matters pertaining to the engineering aspects assuring safe operation of the unit.

6.3 FACILITY STAFF QUALIFICATION 6.3.1 Each member of the facility staff shall meet or exceed the minimum qualifications of ANSI N18.1-1971 for comparable positions, except for (1) the Hanager - Environmental & Radiation Control who shall meet or exceed the qualifications of Regulatory Guide 1.8, September 1975 and (2) the Shift Technical Advisor who shall have a bachelor's degree or squivalent in a scientific or engineering discipline with specific training in plant design, and response and analysis cf the plant during transients and accidents.

6.4 TRAINING 6.4.1 A retraining and replacement training program for th

'acility staff shall be maintained under the direction of the Manager - Training (BSEP) and shall meet or exceed the requirements and recommendations of Section 5.5 of ANSI N18.1-1971 and Appendix "A" of 10 CFR Part 55.

6.4.2 A training program for the Fire Brigade shall be maintained under the direction of the Manager - Training (BSEP) and shall meet or exceed the requirements of Section 27 of the NFPA Code-1975.

  • Not responsible for sign-off function.

1NSERT ( abbachecl)

BRUNSWICK - UNIT 2 6-5 Amendment No. 170

i t

(

1 l

i

-Insert for Footnote (a):

I (a) The requirement for the' Manager Operat. ions to hold or have held a seutor reactor operator license is exempted for a period of 18 months starting from (the date of amendment issuance).