05000260/LER-1982-033, Forwards LER 82-033/03L-0

From kanterella
(Redirected from ML20066H647)
Jump to navigation Jump to search
Forwards LER 82-033/03L-0
ML20066H647
Person / Time
Site: Browns Ferry 
Issue date: 11/15/1982
From: Green H
TENNESSEE VALLEY AUTHORITY
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML20066H656 List:
References
NUDOCS 8211230324
Download: ML20066H647 (1)


LER-1982-033, Forwards LER 82-033/03L-0
Event date:
Report date:
2601982033R00 - NRC Website

text

_

.i TENNESSEE VALLEY AUTHORITY CH ATTANOOGA, TENNESSEE 37401 1750 Chestnut Street Tower II b

?lw$

h, November 15, 1982

$p e

p 3

Mr. James P. O'Reilly, Director U.S. Nuclear Regulatory Commission Office of Inspection and Enforcement Region II 101 Marietta Street, Suite 3100 Atlanta, Georgia 30303

Dear Mr. O'Reilly:

TENNESSEE VALLEY AUTHORITY - BROWNS FERRY NUCLEAR PLANT UNIT 2 - DOCKET No. 50-260 - FACILITY OPERATING LICENSE DPR REPORTABLE OCCURRENCE REPORT BFRO-50-260/82033 The enclosed report provides details concerning reduced methyl iodine removal efficiency of primary containment purge system charcoal filters.

This report is submitted in accordance with Browns Ferry unit 2 Technical Specification 6.7.2.b(2).

Very truly yours, TENNESSEE VALLEY AUTHORI M

11. J. Green Director of Nuclear Power Enclosure cc (Enclosure):

Document Control Desk U.S. Nuclear Regulatory Commission Washington,.D.C.

20555 Records Center Institute of Nuclear Power Operations Suite 1500 1100 Circle 75 Parkway Atlanta, Georgia 30339 O ":d @

NRC Inspector, Browns Ferry E

t 8211230324 821113 PDR ADOCK 05000260 S

PDR An Equal Opportunity Employer