ENCLOSURE 3 V0GTLE ELECTRIC GENERATING PLANT REQUEST TO REVISE TECHNICAL SPECIFICATION 3.4.6.1 INSTRUCTIONS FOR INCORPORATIQ!f The proposed change to the Vogtle Unit I and Unit 2 Technical Specifications would be. incorporated as follows:

Remove Paae Insert Paae 3/4 4-19 3/4 4-19 i

l l

E3-1 9012050004 90112e l-PDR ADOCK 05000424 P

PDC

+,

,i REACTOR COOLANT SYSTEM 4

3/4.4.6 REACTOR COOLANT SYSTEM LEAKAGE LEAKAGE DETECTION SYSTEMS I

LIMITING CONDI~ ION FOR OPERATION 4

3.4.6.1 The following Reactor Coolant System Leakage Detection Sys'tems shall be OPERABLE:-

Y The Containment Atmosphere Gaseous or Particulate Radioactivity a.

Monitoring System,-

E b.

The Containment Normal. Sumps Level and Reactor Cavity Sump Level, and c

?

c.

Either the containment air cooler condensate flow rate or a 1

Containment Atmosphere Gaseous or Particulate Radioactivity Monitoring System not taken credit for in 3.4.6.la.

APPLICABILITY:

MODES 1, 2, 3, and 4.

4

' ACTION:

j l0.With only two of the,above required Leakage Detection Systems OPERABLE,_

-operation may continue for up to 30 days provided grab samples of the contain-

ment atmosphere are obtained and analyzed at least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> when the 4

required Gaseous'or Particulate Radioactive Monitoring System is inoperable-otherwise, be in at least HOT STANDBY within the mxt 6. hours and in COLD

-SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

Y. ---+

W

'1 SURVEILLANCE REQUIREMENTS.

\\

y

'i-

4.4.6._1M The Leakage Detection Srstems shall be desion arated W ERABLE by

f ContainmentLAtmosphereGaseousandParticulateMonitoringSystems-a..

c

performance of CHANNEL; CHECK,. CHANNEL CALIBRATION, and ANALOG CHANNEL OPERATIONAL iEST at the frequencies
specified in Table 4.3-3,.

g t

'b.

Containmer'. Normal Sumps Level and. Reactor Cavity Sump Level per-

[

formance of CHANhEL CALIBRATION at leastionce per 23 months, and k

Containment Air Cooler Condensate Mari'.oring Syste.a performance of c.

!l:

t CHANNEL CALIBRATION at least once per 18 months, i

(EWi+h \\ess %n +4 of ne. above reku;<ed Lea kcme. De+ee.+ron 10PeRA B L6, be. in M Icost HOT 5T M D By kli% M fhe. ne et 6 61ws LL 7

andjn ' COLD. S HUTor wu wi+hin Me. Fo llowig s o hours, y,

A V0GTLE-UNITS l 1 & 2 3/4 4-19 m'

?