Advises That Test Rept Re Veritrak RCS wide-range Pressure Transmitter Reviewed & Accepted by Util,Per Util 820723 & 0929 Ltrs
ML20064D538
Person / Time
Site: Summer South Carolina Electric & Gas Company icon.png
Issue date: 12/30/1982
From: Dixon O
SOUTH CAROLINA ELECTRIC & GAS CO.
To: Harold Denton
Office of Nuclear Reactor Regulation
References
NUDOCS 8301040681
Download: ML20064D538 (1)


Text

,

l SOUTH CAROLINA ELECTRIC St GAS COMPANY Fost OFFICE 764 CoLuualA, south CAROUNA 29218 O. W. DixoN JR.

Vict PRESIDENT December 30, 1982 NUCLEAR OPERATIONS Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C.

20555

Subject:

Virgil C. Summer Nuclear Station Docket No. 50/395 Operating License No. NPF-12 Equipment Qualification Veritrak Transmitter

Dear Mr. Denton:

As discussed in our letters dated July 23, 1982, and September 29, 1982, South Carolina Electric and Gas Company (SCE&G) committed to have the review and acceptance of the test report concerning the reactor coolant system wide range pressure transmitter, manufactured by Veritrak, completed by December 31, 1982.

This letter is written to inform you that the test report has been received, reviewed, and accepted by SCE&G.

If you require additional information, please advise us.

Very truly yours,

.-4 #1L O.

W. Dixon Jr.

WRM:OWD/lkh cc:

V.

C.

Summer R.

B.

Clary G.

H.

Fischer O.

S. Bradham A.

R.

Koon H.

N.

Cyrus T.

C. Nichols, Jr.

M.

N.

Browne O. W.

Dixon, Jr.

G.

J. Braddick M.

B.

Whitaker, Jr.

J.

L.

Skolds fg{

J.

P.

O'Reilly J.

B.

Knotts, Jr.

H.

T.

Babb B.

A.

Bursey D.

A.

Nauman NPCF C.

L. Ligon (NSRC)

File W.

A.

Willians, Jr.

8301040681 821230 PDR ADOCK 05000395 P

PDR