Letter Sequence Other |
---|
EPID:L-2019-LLA-0273, Submission of a Responses to the NRCs Request for Supplemental Information for the NAC International Magnastor Cask System Amendment No. 10 (Open) |
|
MONTHYEARML20064D4672020-03-0404 March 2020 Application for Amendment No. 10 to the Model No. Magnastor Storage Cask - Request for Supplemental Information Project stage: Other ML20143A1022020-05-13013 May 2020 Submission of a Responses to the NRCs Request for Supplemental Information for the NAC International Magnastor Cask System Amendment No. 10 Project stage: Request ML20143A1082020-05-29029 May 2020 Magnastor Amendment 10 Acceptance Letter Project stage: Acceptance Review ML20258A1612020-10-0808 October 2020 Magnastor Amd 10 non-proprietary RAI Enclosure Project stage: RAI ML20258A1592020-10-0808 October 2020 Magnastor Project stage: Request ML20258A1602020-10-0808 October 2020 Magnastor Application Amendment 10 - First Request for Additional Information Letter Project stage: RAI ML21067A0432021-02-28028 February 2021 Enclosure 1 - NAC International Responses to the Us Nuclear Regulatory Commission Request for Additional Information 1 for Magnastor FSAR RAI Responses for Amendment 10, Revision 21A Project stage: Request ML21118A0432021-04-20020 April 2021 NAC International, Inc., Supplemental Responses to the NRCs Request for Additional Information for the Cask System Amendment No. 10 Project stage: Supplement ML21165A0342021-06-14014 June 2021 Notice of Public Meeting with NAC International to Discuss Amendment No. 10 to the Magnastor Storage System Project stage: Meeting ML21173A3492021-06-14014 June 2021 Revised Notice of Public Meeting with NAC International to Discuss Amendment No. 10 to the Magnastor Storage System Project stage: Meeting ML21174A0742021-07-12012 July 2021 Request for Additional Information Magnastor Storage System Amendment No. 10 Project stage: RAI ML21174A0722021-07-12012 July 2021 Magnastor Amd 10 Second RAI Project stage: Request ML21174A0732021-07-12012 July 2021 Application for Amendment No. 10 to the Model No. Magnastor Storage Cask - Second Request for Additional Information Project stage: RAI ML21259A2072021-09-16016 September 2021 Notice of Partially Closed Meeting with NAC International for a Discussion of Low Wind Speed Analysis for Amendment No. 10 to the Magnastor Storage System Project stage: Meeting ML21298A2022021-11-12012 November 2021 Summary of June 30, 2021, Meeting with NAC on Magnastor Amendment 10 Project stage: Meeting 2021-11-12
[Table View] |
|
---|
Category:Letter
MONTHYEARML24226B2182024-09-0606 September 2024 Cover Letter - Request for Additional Information for Review of the Magnastor Storage System Amendment No. 15, Certificate of Compliance No. 1031 ML24219A2272024-08-0606 August 2024 NAC International Magnastor Cask System Amendment No. 14 Supplement ML24179A0722024-06-26026 June 2024 Submittal of Responses to the Nuclear Regulatory Commission Request for Additional Information for NAC International Magnastor Cask System Amendment No. 14 ML24169A5902024-06-21021 June 2024 NRC Approval of NAC International Request for Withholding Information Magnastor Amendment 15 ML24149A3682024-06-0505 June 2024 Request for NAC International Magnastor Cask System Amendment 15 - Accepted for Review - Cost Activity Code/Enterprise Project Identification Number 001028/L-2023-LLA-0143 ML24120A0362024-05-0707 May 2024 Application for Amendment No. 14 to the Model No. Magnastor Storage Cask - Request for Additional Information ML24082A1302024-04-18018 April 2024 NAC International - USNRC Inspection Report 0721031/2023201 Final Letter ML24108A1982024-04-16016 April 2024 Independent Spent Fuel Storage Installation - Registration of Dry Spent Fuel Storage Casks with Applied Changes Authorized by an Amended Certificate of Compliance ML24088A1752024-04-0909 April 2024 Amendment No. 14 and Magnastor Revisions to the Model No. Magnastor Storage Cask - Acceptance Letter ML24047A3632024-02-16016 February 2024 Independent Spent Fuel Storage Installation - Registration of Dry Spent Fuel Transportable Storage Canisters Identification Numbers AMZDFX177, AMZDFX178, AMZDFX179 Vertical Concrete Cask Identification No. AMZDNE179, AMZDNE178 ML24008A2482024-01-0808 January 2024 NAC International, Response to Apparent Violations (a and B) in NRC Inspection Report 72-1031/2023-201; EA-2023-069 ML23283A2382023-12-0707 December 2023 NAC International, Inc. - U.S. Nuclear Regulatory Commission Inspection Report 72-1031/2023-201 ML23300A1382023-10-26026 October 2023 Supplement to NAC Internationals Submission of an Amendment Request for the NAC International Magnastor Cask System Amendment No. 15 ML23305A0462023-10-26026 October 2023 Submittal of Data Files to Support the Request to Amend the U.S. Nuclear Regulatory Commission Certificate of Compliance No. 1031 for the NAC International Magnastor Cask System, AmendmentNo.15, Supplement 01 ML23291A1672023-10-18018 October 2023 Supplement to the Amendment Request No. 14 for the NAC International Magnastor Cask System ML23258A2332023-09-15015 September 2023 Submission of Replacement Pages for Supplemental Responses to the Nuclear Regulatory Commissions (NRC) Request for Additional Information for the NAC International Magnastor Cask System, Amendment No. 13 ML23250A3242023-09-12012 September 2023 1. Transmittal Letter Magnastor Issuance of Amendment Nos 11 and 12 and Revision of Amendment Nos 0 Through 9 ML23241B0532023-08-29029 August 2023 Submission of an Amendment Request for the NAC International Magnastor Cask System Amendment No. 15 ML23243A8492023-08-29029 August 2023 NAC International, Submittal of Data Files to Support the Request to Amend the U.S. Nuclear Regulatory Commission Certificate of Compliance No. 1031 for Magnastor Cask System, Amendment No.15 ML23229A4812023-08-17017 August 2023 Submittal of Supplemental Responses to the Nuclear Regulatory Commissions (NRC) Request for Additional Information for the NAC International Magnastor Cask System, Amendment No. 13 ML23207A2492023-07-26026 July 2023 Independent Spent Fuel Storage Installation - Registration of Dry Spent Fuel Transportable Storage Canister Identification Numbers AMZDFX167 and AMZDFX169 and Vertical Concrete Cask Identification Numbers ML23205A2382023-07-24024 July 2023 Submittal of an Amendment Request for the NAC International Magnastor Cask System Amendment No. 14 ML23208A0622023-07-24024 July 2023 NAC International - Submission of Data Files to Support the Nuclear Regulatory Commissions (NRC) Review of Magnastor Amendment No. 14 ML23166B0832023-07-0505 July 2023 Independence Spent Fuel Storage Installation - Issuance of Exemption ML23178A2252023-06-27027 June 2023 Submission of Responses to the Nuclear Regulatory Commissions (NRC) Request for Additional Information for the NAC International Magnastor Cask System, Amendment No. 13 ML23143A3912023-05-23023 May 2023 Independent Spent Fuel Storage Installation - Request for Exemption from NAC-MAGNASTOR Certificate of Compliance 72-1031 - Cask Lid Batch 3 Design Requirements ML23074A2522023-03-29029 March 2023 Application for Amendment No. 13 to the Model No. Magnastor Storage Cask – Request for Additional Information ML23076A2272023-03-17017 March 2023 Independent Spent Fuel Storage Installation, Registration of Dry Spent Fuel Transportable Storage Canister Identification Numbers AMZDFX165 and AMZDFX166 and Vertical Concrete Cask Identification Numbers ML23005A2572023-01-0505 January 2023 Request to Withdraw Administrative Controls for Adverse Weather Events During Operations from Magnastor Amendment 12 Supplement ML22349A4682022-12-19019 December 2022 Amendment No. 10 to Certificate of Compliance No. 1031 for the Magnastor Storage System ML22340A5902022-12-0808 December 2022 Acknowledgement Letter - Magnastor Amendment 13 ML22327A2252022-11-23023 November 2022 NAC International - Magnastor Cask System Users CoC Amendment 12 Supplement and Intent to Adopt Letters ML22321A2682022-11-17017 November 2022 Supplement to the Submission of an Amendment Request for the NAC International Magnastor Cask System, Amendment No. 13 ML22308A1942022-11-0909 November 2022 NAC International, Inc. - U.S. Nuclear Regulatory Commission Report No. 72-1031/2022-201 ML22287A0382022-10-13013 October 2022 Supplement to the Submission of an Amendment Request for the NAC International Magnastor Cask System, Amendment No. 13 ML22257A2562022-09-14014 September 2022 Registration of Dry Spent Fuel Transportable Storage Canisters Identification Numbers AMZDFX170 and AMZDFX174 and Vertical Concrete Cask Identification Numbers AMZDNE170 and AMZDNE174 ML22230D0802022-08-18018 August 2022 Independent Spent Fuel Storage Installation - Registration of Dry Spent Fuel Transportable Storage Container ML22216A1102022-08-0404 August 2022 Magnastor Cask System Users CoC Amendments 0 Thru 9 Intent to Adopt Letters ML22208A0782022-07-27027 July 2022 Registration of Use of Cask to Store Spent Fuel ML22196A0232022-07-15015 July 2022 Submittal of Supplemental Information to the NRCs Request for Additional Information for the NAC International Magnastor Cask System Amendment No. 11 ML22201A0662022-07-13013 July 2022 NAC International, Inc., Submittal of Data Disk for the Magnastor Cask System, Amendment No. 13 ML22194A9082022-07-13013 July 2022 NAC, Submittal of an Amendment Request for the NAC International Magnastor Cask System, Amendment No. 13 ML22111A3572022-05-16016 May 2022 Letter Issuing Exemption to Catawba ML22111A3112022-05-16016 May 2022 Letter Issuing Exemption to McGuire ML22110A1112022-05-13013 May 2022 Letter Issuing Exemption to TMI-1 ML22111A2842022-05-13013 May 2022 Independence Spent Fuel Storage Installation - Issuance of Exemption ML22125A1532022-05-0505 May 2022 Registration of Use of Casks to Store Spent Fuel ML22118B1622022-04-28028 April 2022 Request for Exemption from NAC-MAGNASTOR Certificate of Compliance 72-1031 - Cask Lid Design Requirements - Supplement RS-22-062, Supplemental Information to Exemption to the Requirements of Certificate of Compliance No. 1031 for the NAC Magnastor Storage System2022-04-26026 April 2022 Supplemental Information to Exemption to the Requirements of Certificate of Compliance No. 1031 for the NAC Magnastor Storage System ML22108A1972022-04-18018 April 2022 RAI Response to NACs Amendment Request for the NAC International Magnastor Cask System Amendment No. 12 2024-09-06
[Table view] Category:Request for Additional Information (RAI)
MONTHYEARML24226B2182024-09-0606 September 2024 Cover Letter - Request for Additional Information for Review of the Magnastor Storage System Amendment No. 15, Certificate of Compliance No. 1031 ML24226B2202024-09-0606 September 2024 Enclosure - Request for Additional Information - Magnastor Amendment 15 - Non-Proprietary RAIs ML24120A0362024-05-0707 May 2024 Application for Amendment No. 14 to the Model No. Magnastor Storage Cask - Request for Additional Information ML23074A2522023-03-29029 March 2023 Application for Amendment No. 13 to the Model No. Magnastor Storage Cask – Request for Additional Information ML22095A1022022-04-13013 April 2022 Enclosure 1 Magnastor Amendment 12 RAI 1 Non-Proprietary ML21174A0742021-07-12012 July 2021 Request for Additional Information Magnastor Storage System Amendment No. 10 ML21047A2012021-02-26026 February 2021 Non-proprietary Request for Additional Information Enclosure ML21047A1992021-02-26026 February 2021 Application for Amendment No. 11 to the Model No. Magnastor Storage Cask - First Request for Additional Information ML20258A1612020-10-0808 October 2020 Magnastor Amd 10 non-proprietary RAI Enclosure ML20064D4672020-03-0404 March 2020 Application for Amendment No. 10 to the Model No. Magnastor Storage Cask - Request for Supplemental Information ML19354B6372020-01-0707 January 2020 Exemption Request for NAC Magnastor Cask Loaded to Incorrect Helium Backfill Density Request for Additional Information ML20086J5522019-10-0909 October 2019 Request for Additional Information - Enclosure ML19056A0582019-02-22022 February 2019 Enclosure 1: Non-Proprietary RAI (Letter to W. Fowler Application for Amendment No. 8 to the Model No. Magnastor Storage Cask - Request for Additional Information) ML18032A4412018-02-0101 February 2018 Enclosure 1: Request for Additional Information (Non-Proprietary) (Letter to W. Fowler Application for Amendment No. 8 to the Model No. Magnastor Storage Cask-Request for Additional Information) 2024-09-06
[Table view] |
Text
March 4, 2020 Mr. Wren Fowler Director, Licensing Engineering NAC International 3930 East Jones Bridge Road, Suite 200 Norcross, GA 30092
SUBJECT:
APPLICATION FOR AMENDMENT NO. 10 TO THE MODEL NO.
MAGNASTOR STORAGE CASK - REQUEST FOR SUPPLEMENTAL INFORMATION
Dear Mr. Fowler:
By letter dated December 9, 2019 (Agencywide Documents Access and Management System Accession No. ML19345E594), NAC International (NAC) submitted an application for Amendment No. 10 to the Model No. MAGNASTOR storage cask. The application proposes to add a new metal storage overpack. Staff performed an acceptance review of your application to determine whether the application contains sufficient technical information in scope and depth to allow the staff to complete a detailed technical review.
This letter is to advise you that, based on our acceptance review, the application does not contain sufficient technical information. The information needed to continue our review is described as a request for supplemental information (RSI) in the enclosure to this letter. Please note that addressing this RSI does not preclude the staff from issuing further requests for additional information during the course of the detailed technical review of this application.
In order to schedule our technical review, the RSI response should be provided within 2 weeks from the date of this letter. If the RSI responses are not received by this date, the application may not be accepted for review and the staff may discontinue any further review.
Please reference Docket No. 72-1031 and Enterprise Project Identifier (EPID) No.
L-2019-LLA-0273 in future correspondence related to this request.
Sincerely,
/RA/
Bernard H. White IV, Senior Project Manager Storage and Transportation Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards Docket No. 72-1031 EPID No. L-2019-LLA-0273 Enclosure
ML200064D467 *via email OFFICE DFM DFM DFM DFM DFM NAME BWhite WWheatley* JSolis* YDiaz-Sanabria* JMcKirgan DATE 2/13/2020 2/14/2020 2/14/2020 2/14/2020 3/4/2020 Request for Supplemental Information Model No. MAGNASTOR Storage System Docket No. 72-1031 This request for supplemental information (RSI) identifies information needed by the staff in connection with its acceptance review of the Model No. MAGNASTOR storage cask application, dated December 9, 2019 (Agencywide Documents Access and Management System Accession No. ML19345E594).
The requested information is listed by chapter number and title in the applicants safety analysis report (SAR).
4.0 Thermal Evaluation Show that low-wind speeds do not adversely impact the fuel peak clad temperature or other components important to safety such that the components exceed their allowable temperature limits.
Section 4.1 of the SAR states that in the MSO, air exits through 24 outlet holes and two robot access holes. Section 4.11 of the SAR states that since the configuration is symmetrical, the inlets and outlets are simplified into a two-dimensional axisymmetric model by using equivalent dimensions for the air inlets and outlets, which are assumed to extend around the MSO periphery. Normal low-speed wind could affect the cask thermal performance (by inhibiting the air flow at the outlet vents which could have an impact on the cooling effect by reducing the mass flow rate through the annular gap) because of the many axi-symmetric outlet openings resulting in higher predicted temperatures compared to quiescent conditions. The staff has performed three-dimensional (3-D) sensitivity calculations based on a range of wind speeds which is typically considered normal (in the range of 0 to 15 miles per hour) to obtain bounding speeds for several cask designs. The staffs 3-D model included an extended domain to represent the surrounding environment. Details of these analyses were documented in NUREG-2174 Impact of Variation in Environmental Conditions on the Thermal Performance of Dry Storage Casks.
The staff needs this information to have assurance predicted temperatures remain below allowable limits during long term storage.
This information is needed to determine compliance with 10 CFR 72.236(b) and 72.236(f).
Enclosure