Text
_. -
e, 4:
LASALLE COUNTY STATION UNIT 1 STRUCTURAL BOLTING TIGHTNESS INSPECTION PROGRAM FOR CONTAINMENT VALVES INSPECTION RESULTS (Inspection Performed July 1, 2, 6, & 7, 1982)
REPORTED BY:
E E. E. FALB Project Construction Department REVIEWED BY:
!)3' Y
.e D. L. SHAMBLIN Site Project Superintendent 8208170226 820810 DR ADOCK 05000373 PDR f
LASALLE COUICY STATION ETIT 1 STRUCTURAL BOLTDIG TIGRTNESS INSPECTION RESULTS *
'FOR ColGADM:1E VALVES MOTOR OPERATED VALVES UO. OF TIGHTIIESS DISCREPANCIES 2
YOKE /BORITET BOLTING 2
OPERATOR / YOKE BOLTDiG ESSDEIAL OPERATOR ASSEMBLY BOL'45NG 1
Alldiscrepanciesfound(whenconsideredonanindividualbasis)appearnon-significant in respect to satisfactory operation of the valve. All problem bolted connections were at least 75% of specified torque.
At least one bolt was checked with a torque wrench on each bolted connection.
If the use of hand tools was required on the other bolts, the torqued bolt was loosened with a hand wrench and then retightened to the same position to give the workman an accurate sense of the anount of force required to properly
[
tiShten the bolts.with hand tools. 'Ihis procedure is en improvement over the one outlined in the original inspection program.
SPECIFIC DISCREPANCIES FOUlTD ON MOTOR OPERATED VALVES Y0EE/301DTEP BOLTDIG:
1E12-F009 1 of the h bolts was found to be marginally under the lowest allowable torque value for proper bolt preload*;
ho ft-lbs. instead of 50 ft-lbs. specified. This equals 95% of the lowest allowable torque value for the total i
bolted connection.
value based on a previously determined vrench accuracy within +5%
1E51-F063 1 of the h bolts was found to be hand tight. This equals 795 of the specifled torque value for the total bolted connection.
OPE 5tATOR/ YOKE BOLTDiG:
l 1B21-F005 1 of the h bolts was found to be hand tight. This equals 75% of the specified torque value for the total bolted connection.
1 of the li bolts was found to be hand tight. This 1Bf1-F016 equals 796 of the specified torque value for the total bolted connection.
ESSD:TIAL OPEKATOR ASSEMBLY BOLTDIG:
1rn180 1 of the h motor counting bolts was found to be hand
%ight. This equals.75% of the specified torque value for the total motor to operator bolted connection.
e a
w w
C&; TAD:!EliT VALVE STRUCTURAL BOLTD.G
.TIGHTITESS DISPECTION RESULTS (Page #2),
MAIN STEAM ISOLATION VALVES All actuator bolts were visually inspected to essure they were tight against their lockwashers. lio discrepancies were found.
t All tie-rod nuts were checked for proper torque. No discrepancies were found.
MADT STEAM RELIEP VALVES The bonnet and actuator bolt locking devices were inspected on all 18 valves. Discrepancies with locking devices were found in the following L
(all associated bolting was found to be tightened to the proper areas:
torquevalue) ir cylinder tie-rod nut tab washers were bent out of the position (averageof2to3washersoutof8on12 valves) proper 1.
Solenoid valve mounting bolt tab washers were positioned improperly 2.
(cverage of 2 to 3 wachers out of 12 on 16 valves).
On 6 of the 18 valves the tamper seal cable was detached on the 3
threaded plug that covers the relief pressure adjustment screw.
The adjust =ent screws were inspected and found undisturbed.
On one valve 2 lockwires were found damaged on the bonnet / body bolting.
i 14 All of the above discrepancies were resolved under the direction of the Crosby Valve Company service representative.
REACTOR RECIRC FLOW C011 TROL VALVES All actuator bolt locking devices were inspected. Three pairs of actuator' position indicator nounting bolts were missing lockwires on the 1B33-F060A valve.
These lockwires have been replaced.
In additica to the bolt locking device inspection outlined in the original progran, essential yoke to bonnet bolting and actuator rod coupling bolting were inspected to torque valves specified in the vendor instruction manual.
I!o discrepancies were found.
t l
1 t
l
July 9, 1982.
Mr. Warren' Vanle:
Subject:
LaSalle County Station Unit l' Structural Bolting Tightness Inspection Results for Containment Valves I'have reviewed tne subject document which you telecopied to.me on July 9, 1982.
I concur with the disposition and assessment ybu nave i
made in that report.
This concurrence is based on the work that was done to develop tne information transmitted in Sargent & Lundy's June 28, 1982 i
letter.
Altnough they are clearly undesirable, none of the items l
identified in your transmittal if left uncorrected.would have presented a i
safety' problem.
In tne case of tne connection with one hand tight bolt, we believe that the required load would be carried.
This statement is based is carried w.en the' bolt is in place.
The on the fact tnat tne load e
torque values on tne rem'aining bolts would maintain the proper contact on the mating surfaces.
With respect to the locking devices not being properly placed, we again believe the load would De carried since the Dolts were properly torqued.
The locking devices provide additional assurance that the bolted connect,Will riot turn and tnen loosen.
.Your corrective action to restore the bolting to our specified requirements constitutes adequate corrective action.
7 B.R. Shelton BRS/ Dmo /1779L cc:
B.B. Stephenson T.E. Watts D.C. Haan (S&L)
[
7 I ! [.2 INSPECTION DATE FORM # MOV MOTOR OPERATED'VALVF_ STRUCTURAL BOLT TIGHTNESS INSPECTION
/78f VALVE NUMBER / d t / -OO(
SERI AL NUMBER MANUFACTURER h*td O 6 (LS od - SkA 6 N t4006 / L
/
(Use space below to diagram bolts not YOKE / BONNET BOLTING tightened to spec.)
SIZE NM SPEC. TORQUE N/A hfA Ygg g < [O M M {T g AI NO. OF BOLTS k
CHECK HERE IF NO PROBLEMS WERE FOUND.
/g [gf( h/LAL, [A$~f[A/h NfM WRENCH I.D. NO.
M,fA OWNED BY OPERATOR /YOKEBOLTING($M6-000)
(use space below to diagram bolts not
- ""A SIZE 8
S,PEC.TCRQUE 7 IO
- M l
NO.
F RetTS CHECK HERE IF NO PROBLEMS WERE FOUND.
WRENCH I.D. NO. MI' N$
OWNED BY dO N 4 8 [M$ O. 60.
h
$&T$ 0 {/0 OWb b
OPERATOR ASSEMBLY _
PROBLEMS FOUND/ CORRECTIVE ACTION TAKENMOMb l
l Y/ 8E WITNESS.
a PERFORMED BY CECO. Q.C. Dept.
+
Ceco. Project Const.
I
- [NSTAs4 WC o rd Wu p. L. f4Q 4
[. {g. 7ll4 f Tt/
-s-l
~
1
[
b INSPECTION DATE-
' FORM # MOV MOTOR OPERATED VALVF,_ STRUCTURAL BOLT TIGHTNESS INSPECTION Aits7 VALVE NUM3ER /
ZI - Fo op SERIAt NuMBEa MANUFACTURER k N O b Vl 0 0 t " $ $ $ h h] W O O b (Use space below to diagram bolts not YOKE / BONNET BOLTING tightened to spec.)
SIZE M [ M SPEC. TORQUE h OKb ONNbI Alh _
AfNb Mb b
b NO. OF BOLTS h
CHECK HERE IF NO PROBLEMS WERE FOUND.
M c
WRENCH I.D. NO.
A OW:iED BY OPERATOR / YOKE BOLTING dd-000I (use space below to diagram bolts not SPEC. TORQUE 7 h / O N SIZE l
h i
NO. OF OLTS e CHECK HERE IF NO PROBLEMS WERE FOUND.
WRENCH I.D. NO. k I-$$ 3 0WNED BY_ bd Al A M IrJ.S P. 60.
1t SPd&6D 2 f301:rs tsll f30g mfegg y J
OPERATOR ASSEPSLY_
O Alb do UI /VILj j f A/ h PROBLEMS FOUND/ CORRECTIVE ACTION TAKEN aN SvJt{GH Ho us ced G Lo d6 R - tfAPLAC 6 0 l
~74# _l M
WITNESS e
PERFORMED BY CECO. Q.C. Dept.
CECO. Project Const.
MfNSr/tM1 ton pf m pg (zga4
{, {} q[i.q/gv '
n.,
INSPECTION DATE l
.I Y
' FORM i mV MOTOR OPERATED VALVEL. STRUCTURAL BOLT TIGHTNESS INSPECTION M l7b VALVE NUM3ER / O b l - 00b SERIAL NUMBER MANUFACTURER A N O bdi-3 O N ' b d.46 Af (A/ 0 0
/
(Use space below to diagram bolts not YOKE / BONNET BOLTING h[kSPEC. TORQUE,_ N[k N/A YoK6 ( & N^m f 424 SIZE NO. OF BOLTS h CHECK HERE IF NO PROBLEMS WERE FOUND.
N WRENCH I.D. NO.
b OWNED BY OPERATOR /YOKEBOLTING(jdd'OOO)
(Use space below to diagram bolts not SPEC.' TORQUE 7.bd/O booSG SIZE g-NO. OF BOLTS O CHECK HERE IF NO PROBLEMS WERE FOUND. OfcR i
k b " h 9 $
7 WRENCH I.D.
NO.
bOAlA d IAf3 O. bO-
.Ed.SP& &Tb0 j'TL&HTEM E 6
$ 6_ours &l Box wilgrJc OWNED BY OPERATOR ASSEMBLY PROBLEMS FOUND/ CORRECTIVE ACTION TAKEN oM 6 o er r4 L3 S 1 rs 6 0 N S & LT CA H o u S c.M 6 l'D J G R - lL6 PL. A GG D WITNESS y
/
'7-/r9L PERFORMED BY CECO. Q.C'. Dept.
Ceco. Project Const.
- m s m ue n on m au n es &. f.1,4. 1/n ( n
- INSPECTION DATE 7
(p b FORM # MOV MOTOR OPERATED VALVE' STRUCTURAL BOLT TIGHTNESS INSPECTION
/ N " 2.4 b VALVE NUMBER / bf -
Olb SERIAL NUMBER PANUFACTURER k M(,M O /l,-[M A L [M h b L d L T~O ( d Lt d
/
(Use space below to diagram bolts not YOKE / BONNET BOLTING tightened to' spec.)
I 4
F BOLTS b
CHECK HERE IF NO PROBLEMS WERE FOUND.
I - hk N WRENCH I.D.
NO.
0WNED BY b A)kN d3O bE.
OPERATOR / YOKE BOLTING
[ gg (Use space below to diagram bolts not tightened to spec.)
L SIZE I
NO. OF BOLT $h J
C CHECK HERE IF NO PROBLEMS WERE FOUND.
WRENCH I.D. NO. N$'hN S
~ [
OWNED BY h dl b [ N P. b b*
OPERATOR ASSEMBLY _
PROBLEMS FOUND/ CORRECTIVE ACTION TAKEN I OLI6 BOOS $
o iJ S & C %d H oa.5 LN 6 corld (L - ct.sH rgH G o 1
~
+d!
7'b$ b WITNESS PERFORMED BY
~
CEto.8Q.C. Dept.
Ceco. Project Const.
l
- SMB -00 (6/g n f Bot r)
- foa m Ea.ut Va Lv.G MfTs. GLAM6 9 US G D go. 2 t3 21 - Foi 9 I
4.L4. 1(19 (Tv
R i
l f [.b IMSPECTION DATE FORM # MOV MOTOR OPERATED VALVE STRUCTURAL BOLT TIGHTNESS INSPECTION
['" 10 b VALVE NUMBER / b 3 3 -
013 M SERIAL NUMBER MANUFACTURER kd O O O ' b O b8 [ L.L.-
/_ f d 1.[O d_k 01 b
/
1 YOKDB0? NET BOLTING f }
7, D
(Use space below to diagram bolts not j
SIZE [3[4" SPEC. TORQUE[NOO lli) u LfL PL L $Il [. 0.
A No.L6$8 Odsl66 61 i CHECK HERE IF NO PROBLEMS WERE FOUND.
gg3gg
[ ' IN $
WP.ENCH I.D.
NO.
OWNED BY doal Av f MS P. co.
\\f L S V A L.i n f S P. 0 1: I d o L.T - N ACL SA8L6 0U6TO s
ae e w g
bolts not OPERATOR / YOKE BOLTING tightened to spec.)
/O hy gl ON MU NO OF BOLTS T
h UL LTl Mf 9er4o CHECK HERE IF NO PROBLEMS WERE FOUND.
O W"
'o kI-3bI WP.ENCH I.D. NO.
W{ Box.WL2sieM j f7f7.g OWNED BY fA.YA d [ AI3O. k
.tNSP6cx60 2. Bours q
OPERATOR ASSEMBLY PR03LEP.S FOUND/ CORRECTIVE ACTION TAKEN _bhbMEO OO V'd /E _
~
t$ o 61'S LO OS G - 4'L 6 VIT& N 6 0 l
- I Baoxsw Gugx c:ouvn u cr
/
7-Ze87 WITNESS A
PERFORMED BY CECO. Q.C. Dept.
CECO. Project Const.
~ '
'dssy-wwu WORK REClUEST @-
NoC /! /EE.$w I M %J be 6 6 A 4 L idc u f~le b b b o(
l.
LOC'd'. M*i l '" /6 3.f-FOZ3 /1-5' 5' " <.<. '
UNIT -
EcuiPMENewcME k-e 7 6-05 4W/ W g t-jpleMK3&-M2Ol.-i FROILEM/wcRK REQUESTED.
j.-
La. WoWI.0 c.(M %.....:n.& 6 %o tM scJi;.x.wL /x./Ma
....n...
...........v.....s.
... -....,~.-..
- n.:.:..
,a.: s.m..z.m..~. y.s...rw..n. 4.. m.. :- - n. wn..
. :: ~. :r.2...~.m. ;..e:_. ::
- n..m. -
....y.~..
.. ~..
.::.e,..~.. ~...
>.. a.....,
. av.a.m..,- m l. :t.
,s-
- e,-
.e.
. L..* s Ylis O',' ~ %Ms'M.Y0W6,'l. M.'.. tByi O'P,;O,'.Ts O uM O EM O lu O
. /DATE 7,,,., g Qui R E D oVEsT,ED av-
-m.hu,..y% 4 %,
Nc
. s.......s -.:.'.;: n.6. m.. -..-
.. e.-.
- s ~ -..
ym :.
. + :. <.~.. >>.. o
.i; *
. n u-
~.
a.
CEPT. As5nGNED
'L.
. g s <(@*, * ).. r t. * -
,, /f*
MM IM E.M OTHER ^ -
, cf LHIFT SU P. APPR.
r-W-
C MD h.
[. [
f Ai un on y.
LOAD REDUCTION UNIT OUT AGE PRIORITY /f [
~
'YEs O No)g Q,(. 7]
sH OSPECIAL
,g R ELI ABILITY MODIFICATION CODE SAFETY YEs O RELATED Y ES YES O -
wCRK YES O Cuss
_N.O_ m.. _ _ _ _ _ _N O_ _O_
_N_O __________.________NO J F. A. LL,,F OU R NO S. A,R E CH.E.C aC REl.ATED O
A Ov A LS A.
NOT O D.
("E[, EN3R. APPR.
~T rv n
v we-
/ OATE
) I8/6 U BN.y i
/
MAtNT Q,EPT LAf/
t ROUTINE MAINT. O CRAFT CAPABIL'ITY O I r'
('h0 RK INSTRUCTIONS fu m 6 a m Aa.eu
,n.dd e M n, JAR 2.
l
.. w h..c r m.
o l
..s t
~,- *.;;.
l
~ ~.
l
[
. x t
~
l a
m.
I' '
i l
O MINl. TRAVELER:
WORK ANALYST CODE PARTS CHECKED PARTS ASSEMBLEO JOB CODE W.O. O R FU NCTION N O.
SU3Civl5 TON AND FOUND INSTOREROOM
}O O
/
2
/
l _l p 5 C-m l \\
'AV AILABLE UNDER THIS W.R. NO.
'OM Alp (TM '/M q*.
,b
' '~
ATTACHED DOCUMENTATION REQUIREMENT 3 WORK TO SC CONTRACTED P R.
/OATE
,..j r, -
OTHER PO RTION. O. ALI. O P.O. NO.
c*"'""c'*"
- Kt%)/ <j 9-pW' TRAVELER -; L. "*:.~. G O
$21.
REASON FOR CONTRACTING
~
Lo*E" COsr. -
O ExPOsuric LEVEL 2NG O E Mf. [ M f s 7 r. M '*
PROCEDURE' O
& _lE
. -h*fE '
R ED TAG..S..J.5..k. - 0.'.. 5
' 52 7.$.
SP. QUIP.'R EQ'D. ' O WORK ASSIGNED TO '.
- DO C. 'Cp K. ' SqO Syg,
.-}r.,7 y,
m.6 O O
- CODE s.-
~
CODE SPECIAL PART NO'S AND TOOLS USED
".e.
' -' f ]_'.'
-g.'
T...., O gcy,..,.P ?g,7' g,,, ;(.k;'c ' ~
- ~
j,",'[ T f;'P 3 Q f"5T ACT w
-V.
m..A.
.C-
.. h.w. \\c..hl..e
... :r
.n.4,...s
,. A*.9*w, :...
l SCHEDULED W-l STAMT,
...k ' /.
..v*-
. P*::%: g
' TJ.i. :
CREW l
DATE '
MO DA Y R
\\
j f C5HIFT AUTHORIZATION TO
[
g "v
v
' f TOTAt.
START WORK
/DATE
>g MNHR5
.(
' @Q.C. RELEASE
/DATE WORK PERFORMED V.
D h
- D A
- M AINT. FOREMAN COMP.
/DATE
(
\\
~
1 n, rry M
/\\\\
TESTS COMP
/DATE p\\
s I
WORK REQUEST PACKAGE COMPLETE l C AIMOV ED COMPLETION. /D A" V
N
@Q.C. ENG R.
/D ATE OG. A ENG R. O R INS P.
/OATE
~
L h
INSPECTION DAiE
~7
- l. ! [L FORM # MOV MOTOR OPERATED VALVE STRUCTURAL BOLT TIGHTNESS INSPECTION 1-106 VALVE NUMBER / b 3 3' [O 2 3 b SERIAL NUMBER MO O O - d O RR.L L.L [ / I N ffo /LO (J 6 MANUFACTURER
/
YdKE/ BONNET BOLTING I 7, [b (Use space below to diagram bolts not tightened to spec.)
/g[4 SPEC. TORQUE /D0O g g 7,y g g g g
SIZE NO. OF BOLTS M
gg,, y 3 j g gg g 0///lfSOt\\/ @ t\\/ST', k HECK HERE IF NO PROBLEMS WERE FOUND.
WRENCH I.D. NO. (( ' b 8 OWNED BY CO A/ A M iMS P. 84.
A d fo l13 u A L. f HSA 0 f l 00 LT -
g se space below to diagram bolts not OPERATOR / YOKE BOLTING tightened to spec.)
582E b[4" SPEC. TORQUE[/O NO. OF BOLTS Y&
0 CHECK HERE IF NO PROBLEMS WERE FOUNO.
ND 0"D I' b I
% w ~p y c, % j. L %)
M*t v u
q SA O WRENCH I.D.
NO.
OWNED BY(# )(lA // LN $ P. e o,
f LNSpdc;rso L 8oLTS W{ 80 >c tNesa c g. %~' ~
l #"
- Wsdh OPERATOR ASSEMBLY
'M PROBLEMS FOUND/C,0RRECTIVE ACTION TAKEN MO M d 7//f7/j 8
g
/ 'i l
i
/ 7-2-8E WITNESS s/
,f PERFORMED BY CECO. Q.t. Dept.
CECO. Project Const.
I 7 !.D![M INSPECTION DATE FORM f MOV MOTOR OPERATED VALVLSTRUCTURAL BOLT TIGHTNESS INSPECTION 3-2o6 VALVE NUMBER //3 3 3 - Foto7 A SERIAt NUMBER MANUFACTURER h*f NOO b ' Y 0 LR ll l- ( [ D ((O kQ LA 6-
/
(Use space below to diagram bolts not YOKE /50NNET_ BOLTING _
SIZE _f SPEC. TORQUE [OOO NQ. OF BOLTS h
daECxsEREIrNOPROBtEMSWERE80uNo.
uReNCu 1.o. NO. A t-34 2 Maur.L.O.Wo.2.43g hM[Mbd [3[/fO[U(, BOA /3T'bO V
OWNED BY/ d A/MTd IN$ k bO.
\\/L$ne t.- ftl3 A OG 2./30t-73
.ftVA CCGSS At3 L.S 0L&G T (Us s
Iw I s not OPERATOR / YOKE BOLTING tightened to spec.)
[./O O
g NO. y BOLN 'b MCA/
3OQ gCHECK HERE IF NO PROBLEMS WERE FOUND.
OA//8 7.f4 N
.I" WRENCH I.D. NO.
OWNED BY CON A MLMS P. M.
' Bofb. b>o/;fs actc y~errbo /
M txx r ic,yo g ro c
fe Mpfpg76 /oco
- p
[BOl.fMtS3LMf.xR,ww/,#1 OPERATOR ASSEMBLY PROBLEMS FOUND/ CORRECTIVE ACTION TAKEN 5
OtJ SW t TCM HO U S L t& Cat / 6 tl. HLd6 Is f.4 Pv4 CAC 7YSL M
WITNESS
/11#/
PERFORMED BY Ceco. Q.C. Dept.
Ceco. Project Const.
l
7f#b!2L-INSPECTION DATE -
FOR.M i MOV MOTOR OPERATED VALVF, STRUCTURAL BOLT TIGHTNESS INSPECTION 4 - 1O(
VALVE NUMBER [ d 3 3 "
[#Y SERIAL NUMBER MANUFACTURER N LNU 0 0 N O $ A L L L.- f l- [ed C ~f D fl Q l.,4 6
/
(Use space below to diagram bolts not YOKE / BONNET EOLTING_
SIZE / 3!4' SPEC. TORQUE / OO O NO. OF BOLTS k
CHECK HERE IF NO PR03LEMS WERE FOUND.
WRENCH I.D. NO. A t - 3 9 Z Ma LY.1.0. No. 2A 3 2 IAIAIb b bY bO f b/ 5 <* b OWNED BY SB A[A fd IAl8 h. [A._
h$aa v LtJS P. Of LBours -L^lAcc&ssMLG Oagfo OPERATOR / YOKE BOLTING (Use p eb o o
m t not ti9htened t Spec.)
/
FJ 3[4 if
l NO. OF BOLTS HECK HERE 1F NO PROBLEMS WERE FOUND.
URENCH I.D. NO. A & 3 4 2 wir,as,f;ers cou3 pt OWNED BYf0$W { N$ h. U._
NID 7' /0 Nf cS/f(>
r Bfl b/h wek ver<Ad-4 k f Q f, j,gg g OPERATOR ASSEMBLY _
PROBLEMS FOUN0/ CORRECTIVE ACTION TAKEN AlO M b h
OC+. i7-f;2- @/M
"?'I'8' WITNESS e
PERFORMED BY CECO. Q'.C. Dept.
CECO. Project Const.
-s-
7!2 H V JNSPECTION DATE
.F0aM e xav l
MOTOR OPERATED VALVfLSTRUCTURAL BOLT TIGHTNESS INSPECTIO b bh 7 h -[b" f
/ b I2 " kO O #
SERIAL NUMBER VALVE NUM3ER rN M O (. - d M L.C/d(.s L[ d [.fo RQ 4 6 MANUFACTURER I
(Use space below to diagram bolts not
(.;,
tightened to spec.)
f gg.
SIZE SPEC. TORQUE NO. OF BOLTS O CHECK HERE IF NO PROBLEMS WERE FOUND.
gf g
WRENCH I.D. NO. M.6 -"3 lo 40 /k-LOS. (
66 f.7%
ONNED BY D tl A IA [NS P. b.-
Poss.tect G rp
\\l'Aidd Hof - Lov)6R Bours bxbH76d CtJ6 0 P6R.foLT<
(fEUse space below to diagram alts n OPERATOR /YOKEBOLTING(,[dh-0).y i
/
tightened to spec.)
?
Q$ GB 6($$PR.O}{. 2 o*f.QtJb l
g CHECK HERE IF NO PROBLEMS WERE FOUND.
WRENCH I.D. NO. k f. - 3h I OWNED BY [3 N M N.I Al 3 h. b.
Whibbl 0PSWoit Mf&r Fm% G.
OPERATOR ASSEMBLY _
/ 8 O L I' /"! C I $ f Al b PROBLEMS FOUND/ CORRECTIVE ACTION TAKEN Id o u S L sl &c
- d. OU G L M Ltd & G. -
6 ni S vJ t-( c+f ES Pt.n c G D.
7 2-A Z-e WITNESS
~
Ceco. Q.C. Dept.
PERFORMED BY Ceco. Project Const.
! b b 7/'
INSPECTION DATE-FORM # MOV
~
MOTOR OPERATED VALVLSTRUCTURAL BOLT TIGHTNESS INSPECTION VALVE NUM3ER / h 12. " h O h 9 M SERIAL NUMBER M / 2 fjo MkNUFACTURERb t/ 0$ ll] O N < & /L& ( b) V) O O d f f f M f fC l( Q Q YOKE /8ONNET BOLTING (Use space below to diagram bolts not SIZEN!MSPEC. TORQUEN!A NO. OF BOLTS M
A Al LAlf6&R AL 6A.S TLt#4 ffp CHECK HERE IF HO PROBLEMS WERE FOUND.
Al[ A WRENCH I.D.
NO.
!b OWNED BY r
OPERATOR / YOKE BOLTING
[-000 (Use space below to diagram bolts not f
Mghtened to spec.)
8/T SPEC.TORouE 761 t o #4 I
SIZE N0f6' @ Wgdis/C,H U$gg
-4 NO. OF BOLTS N
[
k2
[OM Ub hHECK HERE IF NO PROBLEMS WERE FOUND.
- '7l b,M bCTI,0!
.b A-h N WRENCH I.D.
NO.
bOTOIL ONHED BY f.OYk f1 f tJS P. c,o.
OPERATOR ASSEMBLY PROBLEMS FOUND/ CORRECTIVE ACTION TAKEN d[O blb l
l l
l WITNESS
/
p[8/
'7*E'#2-PERFORMED BY CECO. Project Const.
CECO. Q.C. Dept.
- 11JSrR.u cY 'td M AdaA L
- 3gou ug 73 il FA cfo C no UW- {
l{l A f 2 Lr-enR.n&Or?o
.p p g
}
) l2/ W INSPECTION DATE FORM # MOV I
MOTOR OPERATED VALVL STRUCTURAL BOLT TIGHTNESS INSPECTION
/ / 2 2. 6
/ b (1 ' h09 9 8 SERIAL NUMBER VALVE NUF3ER MANUFACTURER 4 d d 6 d S O d - h(f.,66 M iA/ o O d
/ f d f. f () R Q u d
[
i
(Use space below to diagram bolts not SIZE W /A SPEC.10acuEN/A Mb
] tJ trMGOLAu CAsntJls N0. OF BOLTS CHECK HERE IF NO PROBLEMS WERE FOUND.
N!b WRENCH I.D. NO.
N/A OWNED BY OPERATOR / YOKE BOLTING [jfi d-O O O (Use space below to diagram bolts not SIZE T
SPEC. TORQUE 16i / O NofG : (a" (NLEac+t us G o no.o,,otry g
Ord 6td6 oF I2 %" falou&
CHECK HERE IF NO PROBLEMS WERE FOUND. \\NR GNCH * -7I (O R$f C TL.O M WRENCH I.D. NO. M 1-b $
4 OWNED BY [ O N b d 1th 3 k. CO -
ZNSP6enE D I 6 ot1 VJl 80% 10R GtJCH OPERATOR ASSEMBLY FR03LEMS FOUND/ CORRECTIVE ACTION TAKEN /dC N d
~
Mah 7-2-h
~
WITNESS aw PERFORMED BY
~
Ceco. Q.C. Dept.
CECO. Project Const.
AdaAL # 3 H o u t o 8 6,1 (o.
- 5MSTR.u c.:rto dl6 2 SbGY- {kk.1 l L
-s-00 l' T C 0 N f A d d it M
i!/![k INSPECTION DATE-FORM # MOV MOTOR OPERATED VALVF, STRUCTURAL BOLT TIGHTNESS INSPECTION b
[7h"7'/
VALVE NUMBER /
/'
Ob3 SERIAL NUMBER ANCH o It - 0A-/LL c aJ &
/ L L M L T o /LG u E MANUFACTURER (Use space below to diagram bolts not YOKE / BONNET BOLTING tightened to spec.)
gg 47 SIZE-L SPEC. TORQUE fop of \\/A L.v6 NO. OF BOLTS 4,
O CHECK HERE IF NO PROBLEMS WERE FOUND.
1d9k
~
WRENCH I.D. NO.
OWNED BY CO tvA r1 th/S P. co.
/
1N^is il Bour Loos &
OPERATOR / YOKE BOLTING M d -l )
(Use space below to diagram bolts not tightened to spec.)
//
SIZE h
~
NO. OF BOLTS l
[ CHECK HERE IF NO PROBLEMS WERE FOUND.
I'b$
WRENCH I.D. NO.
OWNED BY b O M k d E M 3 8. O d.
i OPEPATOR ASSEMBLY
/
O L I [iI 3 3 b N b PROBLEKS FOUND/CO.RRECTIVE ACTION TAKEN
-DN S w L f GH Ha u s L M G CO t/G il ML M& & -
A610 0A GG D r
7-/-82 WITNESS PERFORMED BY Ceco. Q.C'. Dept.
CECO. Project Const.
INSPECTION DAT5 7.
[ f.2 L FORM # MOV MOTOR OPERATED VALVE STRUCTURAL BOLT TIGHTNESS INSPECTION i
Al76O VALVE hUMBER / [I / - OIb SERIAL NUMBER
\\Y000/llAl((OA_&U$;
MANUFACTURER N06
$ 0 tb
- hlW$t V
/
(Use space below to diagram bolts not f
' tightened to spec.)
!bSPEC. TORQUEM/A i
Yo K & $ 80N MGT AL6 SIZE gA g
g gggg NO. OF BOLTS
% CHECK HERE IF NO PROBLEMS WERE FOUND.
M/A WRENCH I.D. NO.
N!M OWNED BY (Use space below to diagram bolts not OPERATOR / YOKE BOLTING
'!4
/\\[,-
SIZE M
NO. OF BOLTS CHECK HERE IF NO PROBLEMS WERE FOUND.
WRENCH I.D. NO.M @ - O O 4 f
DWNED BY N0 d.R.L3 o N Co N.S T. CD,
.[MSP2cx20
$60LTSINl'00)( WK6dCd OPERATOR ASSEMBLY NOMS PROBi. EMS FOUND/ CORRECTIVE ACTION TAKEN
/J!
7-3-92.
8 uf WITNESS PERF0PJ/.ED BY CECO. Q.C. Dept.
CECO. Project Const.
- rasverto a mau a ese<r. f.M. 7 /is/rv
INSPECTION DATE
[0RM'f.MOV MOTOR OPERATED VALVE STRUCTURAL BOLT TIGHTHE
\\
I SERIAL NUMBER b h7h ~ b"I VALVE NUMBER /[f 3 3 ' PO O I MANUFACTURER hYO&$ 0 Yl'b $Ll $ (d (Use space below to diagram bolts not
tightened to spec.)
OL;f $ d.
b 42 TO NO. OF BOLTS _
7 ggfgfg7g, O CHECK HE".E IF NO PROBLEMS WERE FOUND.
d% $f(
WEENCH I.D. NO.M I ' h i k p*
- 130LT OWNED BY MhlA M L AfS P. C 0
/ o 0 f.:T. L65.
OPERATOR / YOKE BOLTING [M O-OOO)
(use space below to diagram bolts not tightened to spec.)
~
-7b g _
SIZE _ g f g
[
'~'4 NO. OF BOLTS ECK HERE IF NO PROBLEMS WERE FOUND.
WRENCH I.D. NO. d [.3 9 Y '
OWNED BY[ONM N[M6 k. OO.
i OPERATOR ASSEMBLY PROBLEMS FOUND/ CORRECTIVE ACTION TAKEN 7-Z_N
_ITNESS p;
W
/
' Ceco. Q.C. Dept.
PERFORMED BY
. CECO. Project Const.
- 6M 6 -00 6/g" h fA PPE D Mf 6. HO LE S US G O
{. fk. 1f 19 l 8L-
-s-
I!.h!k'7/
INSPECTION DATE FORM i MOV MOTOR OPERATED VALVE STRUCTURAL BOLT TIGHTNESS INSPECTION b b h l b ~7[o -[
f h 3 3 - h I O' O i
SERIAL NUMBER VALVE HUMBER rN N O C - O M_L f. Af 6, / l f_ M f_ TOM (4. d l
MANUFACTURER
/
l
. YOKE /B0ffNET BOLTING' (Use space below to diagram bolts not tightened to spec.)
r, SIZE SPEC. TORQUE NO. OF BOLTS b
HECK HERE IF NO PROBLEMS WERE FOUND.
WRENCH I.D. NO. [ I ' % 9 $
OWNED BY / o MAM f MS P. eo.
OPERATOR / YOKE BOLTING (hd O'O O O (Use space below to diagram bolts not tightened to spec.)
72 g g
d-NO. OF BOLTS ECK HERE IF.NO PROBLEMS WERE FOUND.
WRENCH I.D. NO. M 1 ' bk OWNED BY b A/ Md [ Als h.
CO.
l OPERATOR ASSEMBLY PR03LEMS' FOUND/ CORRECTIVE ACTION TAKEN Al O Al b N
~
WITNESS t#
PERFORME0 BY CECO. QlC. Dept.
CECO. Project Const.
- Sn 6 -o o (6/s" 4 8ot.r) M16. fi.ArJ M us & D.
(.i.I 7//4/TL-
~
-s-
I"b
^
FORM i MOV MOTOR OPERATED VALVE STRUCTURAL BOLT TIGHTNESS INSPECTION f
bbhlb~7h"3 VALVE NUMBER /533-
/OI SERIAL NUMBER MANUFACTURER ['NM OD O MLL Aldf l1NTSOdOUd
/
(Use space below to diagram bolts not
~
YOKE / BONNET BOLTING tightened to spec.)
7!7 q SPEC. TORQUE 47 SIZE NO. OF BOLTS b
HECK HERE IF NO PROBLEMS WERE FOUND.
WRENCH I.D. NO. A I ~ h N $
OWNED BY [ON NTd bd3 k.OM.
OPERATOR / YOKE BOLTING bd /h -OOD (Use space below to diagram bolts not tightened to spec.)
3by SIZE 6[8 g
~$
NO. OF BOLTS hHECK HERE IF NO PROBLEMS WERE FOUND.
WRENCH I.D. NO. [' b b[
l OWNED BY M M A M.T M $ h. O.
OPERATOR ASSEMBLY _
PROBLEMS FOUND/CO.RRECTIVE ACTION TAKEN h df 5 M /L dCV6 R 80 L75
&l L S S T & b - LL6/)LA CA n 5
h 7 Z-St.
WITNESS PERFORMED BY CECO. Q.C. Dept.
CECO. Project Const.
- 3M 6 -oo ( 6fg " $ 13our ) M19. R.Ata 6 4 uS d e j
(A.4 7/N/3k
/
f INSPECTION DATE i,1I i
FOR!.' J MOV N0 TOR OPERATED VALVE STRUCiURAL BOLT TIGHTNESS INS P3 M O
' 2 i VALVE NUM3ER / b $ 3 ' IOM SERIAL NUMBER
[
PANUFACTURER do C k m/ d L L [ L f d [_70 (Q (d
=j YOXE/BONN5T BOLTIffG (Use space below to diagram bolts not tightened to spec.)
g N
NO. OF BOLTS
.ECX HERE IF NO PROBLEMS WERE FOUND.
1-39 $
WRE?:CH I.D. NO.
OWNED BT 00N A d [N0 h. 00.
M O-O 00)
(Use space below to diagram bolts not tightened to spec.)
OPERATOR / YOKE BOLTING ybg' 3[ __ SPEC. TORQUE
/
' SIZE' f
NO. OF BOLTS h
CHECK HERE IF NO PROBLEMS WERE FOUND.
WRENCH I.D. NO. k b 3 9 3 I
OWNED BY b A/M N(Alb b. (d.
f OPERATOR ASSEMBLY _
MO M S r rJ G.
60 v' 6 R. -
PROBLEMSFOUND/CORRECTIVEACTIONTAKENbtAlC70P MLN665 M1SSinJb L6Av6 As is l
7-2-6 2.
WITNESS gf PERFORMED BY Ceco. Q.~C. Dept.
CECO. Project Const.
$ M6 - 00 6/1" f M 16. 3fM O S US 6 0.
.f. f.
7 M /a 4
/
-s-s
I l!$ k INSPECTION 'DATE FORM # MOV MOTOR OPERATED VALVE _ STRUCTURAL BOLT TIGHTNESS INSPECTION VALVE NUMBER / bf. 3 3 -
/, Ol#
SERIAL NUMBER bb h#h W01k.s0 $N? LLk& ! L[ M LTO [Q U &
YANUFACTURER
/
(Use space below to diagram bolts not YOKE / BONNET BOLTING SIZE SPEC. TORQUE NO. OF BOLTS
@ HECK HERE IF NO PROBLEMS WERE FOUND.
WRENCH I.D. NO. 8_7_-3G/
OWNED BY WAm
/SP 03 OPERATOR / YOKE BOLTING j/v}$..000 (Use space below to diagram bolts not tightened to spec.)
/
f/s#
y
SIZE NO. OF BOLTS Y
hHECK HERE IF NO PROBLEMS WERE FOUND.
WRENCH I.D. NO.
4-I 3G/
OWNED BY (bn/%
Josf Co.%xd h b.
%$peded 3
u n-4 OPERATOR ASSEMBLY PROBLEMS FOUND/ CORRECTIVE ACTION TAKEN don 6 bk WITNESS
/
PERFORMED BY CECO. Q.C. Dept.
CECO. Project Const.
- $M 6 -oo (.6fg" f Bouri pt-rs. ftA as G us20
/z.f.41{t9{8v
-s-
7 2 !kD f
INSPECTION DATE FORM i MOV MOTOR OPERATED VNLVELSTRUCTURAL BOLT TIGHTNESS INS) 26LI36 VALVE NUMBER / v'P t i 3 A SERIAt NUMBER NANUFACTURER_ h tS rf 6 rt 60NT fl0 L S,f L L d LTOILG M 6 (Use space below to diagram bolts not YOKE /BDNNET BOLTING tightened to spec.)
f bIA fthcD it.1 L. ocK vJ1 tL6s kf A SPEC. TORQUE SIZE-4 NO. OF BOLTS CHECK HERE IF NO PROBLEMS WERE FOUND.
N WRENCH I.D. NO.
A OWNED BY (Use space below to diagram bolts not OPERATOR / YOKE BOLTING tightened to spec.)
SIZE _ N,[I A _ SPEC. TORQUE _
h/b (AMO LY L 0GK th tL6 S I,-
NO. OF BOLTS CHECK HERE IF NO PROBLEMS WERE FOUND.
d[A WRENCH I.D. NO.
Af [
OWNED BY 9
OPERATOR ASSEMBLY _
b PROBLE'MS FOUN0/ CORRECTIVE ACTION TAKEN A/O N'
WITNESS
<%A/
v Ceco. Q.C. Dept.
'~~
PERFORME9 BY CECO. Project Const.
e,
FORM # MOV INSPECTION DATE 7
2b i
MOTOR OPERATED VALVE STRUCTURAL BOLT TIGHTNESS INSPECTION h bI3$
VALVE NUMBER / Y P [ [ 3 SERIAL NUMBER LSM 6 L lo^W!tD LS l L.LM CD (LQ M 6 MANUFACTURER
/
(Use space below.to diagram bolts not YOKE / BONNET BOLTING tightened to spec.)
fbSPEC.TORQUIN!M i
FA ego R-Y L o cxw ULE3 l
SIZE i
NO. O BOLTS h
l CHECK HERE IF NO PROBLEMS WERE FOUND.
NfM WRENCH I.D. NO.
!M OWNED BY i
(Use space below to diagram bolts not OPERATOR / IOKE BOLTING t-ightened to spec.)
bhl/M kb NO. OF BOLT CHECK HERE IF NO PROBLEMS WERE FOUND.
~
WRENCH I.D.
NO.
Al!/A OWNED BY OPERATOR ASSEMBLY PROBLEMS FOUND/ CORRECTIVE ACTION TAKEN NO N b f / C h M/ 7-b-b W
WITNESS PERFORMED BY
/
Ceco. Q.Cf Dept.
~
CECO. Project Const.
7 k!$ V INSPECTION DATE FORM ! M3V MOTOR OPERATED VALVE STRUCTURAL BOLT TIGHTNESS INSPECTIO 2/Ob/3[
VALVE NUMBER _/
/ I4 b SERIAL NUMBER hlb $ b S.
DO A]'Y$h L$
l.[ Y [. [ O lt.Q VI $
MANUFACTURER I
(Use space below to diagram bolts not
. YOKE /BONNIT BOLTING tightened to <.;pec.)
/A. SPEC. TORQUE A (AC'fD LY L oct<Wg twS SIZE g
3g g
NO. O BOLTS CHECK HERE IF NO PROBLEPS WERE FOUND.
[S WRENCH I.D. NO.
!b OWNED BY (Use space below to diagram bolts not OPERATOR / YOKE BOLTING tightened co spec.)
' SIZE /d / A SPEC. TORQUE dr A, C A ~ O C 1' L-0 CK'LU.C / LGS j-NO. OF BOLTS 3 gg g HECK HERE IF NO PROBLEMS WERE FOUND.
lA WRENCH I.D.
NO.
h!A OWNED BY l
OPERATOR ASSEMBLY _
PR03LEMS FOUND/ CORRECTIVE ACTION TAKEN dOMb
~
dwe/M 7'7.387 WITNESS PERFORMED BY Ceco. Q.C. Dept.
CECO. Project Const.
7!2 h~
INSPECTION 'DATE'-
F.ORM i MOV MOTOR OPERATED VALVE STRUCTURAL BOLT TIGHTNESS INSPECTI I
bb bl 3 9 I
VALVE NUMBER / f Ik b SERIAL NUMBER
~
kj H G (( 60MT/LOL5 [ L.[/1 Cfa[L g y g f
PANUFACTURER
/
r (Use space below to diagram bolts not YOKE / BONNET BOLTING tightened to spec.).
cac to a.1 poox& ut.ss N h SPEC. TORQUEk[N SIZE I
2
.Sgt u YLG NO.
F BOLTS CHECK'HERE IF NO PROBLEMS WERE FOUND.
N/
WRENCH..I.D. NO.
MM OWNED BY l
(Use space below to diagram bolts not..
I
~
OPERATOR / YOKE BOLTING tightened to spec.)
A SPEC. TORQUE d/A fkeno101 L OCMWL/LG$
l i
SIZE p
g NO. OF BOLTS r
HECK HERE IF NO PROBLEMS WERE FOUND.
!k WRENCH I.D.
NO.
f N, A OWNED BY OPENATOR ASSEMBLY _
A/OM d PROBLEP.S FOUND/ CORRECTIVE ACTION TAKEN i
l 7$$E WITNESS __
i d
PERFORMED BY CECO. Q.C. Dept.
CECO. Project Const.
l E!bb INSPECTION DATE FORM # N0v MOTOR OPERATED VALVE STRUCTURAL BOLT TIGHTNESS INSPECTION VALVE NUMBER [Nb/ 7 SERI AL NUMBER b N 7 h" $ 4 - 2 j
AN M O L - OMuld& / L.C M L10 ft Q t) 6 YANUFACTURER YOKEIBONNET BOLTING' (Use space below to diagram bolts not
' tightened to spec.)
g/If, it gj-SPEC. TORQUE SIZE i
2 l
NO. OF BOLTS CHECK HERE IF NO PROBLEMS WERE FOUND. VittGN C H
.7 i CoNLGextor WRENCH I.D. NO. M [.- 3 4 $
fAcroR*
DWHED BY (LoN A r~1 LNS P M.
3
/
OPEPATOR/ YOKE BOLTING (8Md-000)
(use space below to diagram bolts not SIZE 7
SPEC'. TORQUE 7b NorE: lo" wit s a e H cA s gp NO. OF BOLTS
.gi ON 2N D 0F l8%" tor Qa6
[ CHECK HERE IF. NO PROBLEMS WERE FOUND.
j g
WRENCH I.D. NO. k b '3N b gg g fg,(-W OWNED BY 6.o tJ A c10 S P.
Co.
i OPERATOR ASSEMBLY koNb PROBLEMS FOUND/ CORRECTIVE ACTION TAKEN t
bM 7-2 87.
WITNESS PERFORMED BY Ceco. Q.C.' Dept.
CECO. Ecoject Const.
- 5 r16 -oo 4/s"pdocr?
- 5Hou co 6 6,Wo 6 6 USe u.S.
So Orto 4 FAccor.
G1% fA A. A l & [ L2 /
. ( _ _ } _ l 1 9.l g z.,
~ INSPECTION DATE-
~f I
h2' FORM i MOV MOTOR OPERATED VALVE STRUCTURAL BOLT TIGHTNESS INSPECTION b
$l
' b VALVE NUM3ER / k/
O SERIAL NUMBER N N O d-~~
N dLT Al(1 l I d f. 7 0 ( h (A d MANUFACTURER
/
(Use space below to diagram bolts not YOKE / BONNET BOLTING SIZE.kf SPEC. TORQUE N
NO. OF BOLTS S'
ON GN D Of I8%" To eQu s CHECK HERE IF NO PROBLEMS WERE FOUND. ggg N I' b $
MC;(O /7 WRENCH I.D. NO.
OWNED BY do N A /4L NS P. d.o.
.[ asp 6c12 0 $ Bour.5 vl/ BoK vt!LGrJ cst OPERATOR / YOKE BOLTING h/VJ /3-QOO (Use space below to diagram bolts not 72 SIZE $[f SPEC. TORQUE NO. OF BOLTS ON 2N D o f 18 % " 1'o tt au s CHECK HERE IF NO PROBLEMS WERE FOUND.tuiLcnce a.11 eoteccsrre WRENCH I.D. NO. p 1 - 39 g hh'70 (*M~
OWNED BYf; ^1 A M L /JS P. c.o.
\\/LS a A-t
.fM5 P. Of f 6 o i r - LMACc.SSS A B LG 0id 6 ft
{# f 8 O A/ O() 1 T OPERATOR ASSEMBLY PRO 3LEMS FOUND/CO,RRECTIVE ACTION TAKEN / dOTO/
L.D O S & - T t G H f G N G C.
[
7^ S 4-WITNESS PERF0PJ4ED BY CECO. Q.'C. ' Dept.
Ceco. Project Const.
-+# Sin e-oo (4/g"p 6ourl
""SnouLe 62.16 twrra.
ww&G usco.s.
Boitascnod facon LLJKliv fg. '7]tJ l2
~
' INSPECTION DATE FORM i MSIV MAI$ STEAM ISOLATION VALVE ACTUATOR
' BOLT LOCKING HARDWARE AND HYORAULIC CYLINDER TIE ROD TIGHTNESS INSPECTION NA-d-i VALVE NUMBER /82/-FOM 4 SERIAL NUMBER MANUFACTURER Rockwell Manufacturing Company _
General Electric Company SUPPLIER (Use diagram below to identify )
HYDRAULIC CYLINDER TIE ROD BOLTING bolts not tightened to spec.
NO. OF BOLTS 4
TOP OF VALVE g
J TORQUE SEQUENCE cross corner j
CHECK HERE IF NO PROBLEMS WERE FOUND.
3 l
WRENCH 1.D. NO. M SoTo co#. hofe F-RA 0
hJ OWNED BY Cec &
Y t
ACTUATOR ' ASSEMBLY _
(Jf bolt tightening is required, list torque PROBLEMS FOUND/ CORRECTIVE ACTION TAKEN: Identify missing or defective b value used and reference.
de A W, Y _ W 0 b l ~l )- N S 2 2 -n Y ' & Y L ~ b 0}
_mj W d DJAEA
}l'A DL,%/&1A N n btla,u k..k 7 '
[
c44e AMe 7kdw
,/ - l m,
$ h d e7 n~/w AAYL, m
WRENCH I.D.,NOA f'O 8
_0WNED BY[64M Am DdN PERFORMED BY M
> f u _ WITNESS ///CEqpf. Q.C. ppt.
" CECO. Project fonst. -
,..-..-___,---.,,_.r--....--._
INSPECTION DATE
/
FORM i MSIV i
i MAIN STEAM ISOLATION VALVE ACTUATOR BOLT LOCKTNG HARDWARE AND HYDRAULIC CYLINDER TIE ROD TIGHTNESS INSPECTION l
k4-$
VALVE NUMBER /Bo?/- FOdd A SERIAL NUMBER MANUFACTURER Rockwell Manufacturing Company SUPPLIER General Electric Company HYDRAULIC CYLINDER TIE ROD BOLTING (Use diagram below to identify )
bolts not tightened to spec.
_NO. OF BOLTS 4
TOP OF VALVE l
cross corner' TORQyESEQUENCE D
YCHECK HERE IF NO PROBLEMS WERE FOUND.
WRENCH I.D. NO. M SO90 coh. Dde
'/-8,2.
OWNED BY Ceco 7
i ACTUATOR ASSEMBLY i
LIf bolt tightening is required, list torque PROBLEMS FOUND/ CORRECTIVE ACTION TAKEN: Identify missing or defective B value used and reference.
GA 0 $ ?O h ? -S S b n $ A S C WA A YJ sY'
<>A M
y' m LJ Z
mA. M i,LJ D% o-,L a
'~ ' '
~
L/ _w G
ow r d ' a Ast~
0 l
l.
WRENCH I.D. N0/4f 6'd [d OWNED BYd h68 MA7. /)8//
44., 7-7 & L _WITHESSh bo 7-2.--
PERFORMED BY /
CGo.Q.CyDept.
CECO.ProjectCopt.
~
INShECTIONDATE 7"7-1_ -
FORM # MSIV MAIN STEAM ISOLATION VALVE ACTUATOR BOLT LOCKING HARDWARE AND HYDRAULIC CYLINDER TIE ROD TIGHTNESS INSPECTION K A VALVE NUMBER /82/-70%I. C, SERIAL NUMBER MANUFACTURER Rockwell Manufacturino Company SUPPLIER General Electric Company HYORAULIC CYLINDER TIE ROD BOLTING (Use diagram below to identify )
bolts not tightened to spec.
NO. OF BOLTS 4
TCP 0F VALVE l
l TORQUE SEQUENCE cross corner
.A 2
hHECK HERE IF NO PROBLEMS WERE FOUND.
cal. JA YlBG i
WRENCH I.D. NO.M SO9D OWNED BY 47 'Co l
ACTUATOR-ASSEMBLY (Jf bolt tightening is required, lis.t torque PROBLEMS FOUND/ CORRECTIVE ACTION TAKEN: Identify missing or defective bo l
value used.and reference.
5 $O $ L&3 &.. W__A 2-b_-
0 42./>*
,-c-n-
sb2 W
i
>%t.
.L _ d?A. L2. A,,O ?'2h L o,u ~ -
MM" 5
n y(
\\
fL:,
0
// ge d*aaY Ub?y QCCaphh6-i v
Mp[
WRENCH I.D. NO. N[O f C 0WNED BY 6 840 M/>1
/
4 7-2 -s L WITHESS/;/
2 7 4 -) L
~
CECO.Q.Q' Dept.
PERFORMED BY CECO. Project fp6st.
i l 1
7UDh INSPECTION DATE FORM i MSIV r
PAIN STEAM ISOLATION VALVE ACTUATOR BOLT LOCKING HARDWARE AND HYDRAULIC CYLINDER TIE ROD TIGHTNESS INSPECTION I d '~ b l SERIAL NUMBER VALVE NUMBER 1R)/- Fo ;llb e
MANUFACTURER _
Rockwell ihnufacturing Company SUPPLIER General Electric Company i
HYDRAULIC'CYLINPER TIE ROD BOLTING (Use diagram below to identify )
bolts not tightened to spec.
NO. OF BOLTS 4
l TOP OF VALVE TORQUE SEQUENCE cross corner' b CHECK HERE IF NO PROBLEMS WERE FOUND.
g g
MRENCH I.D. NO. M AD90 Cal/.Defe Y~8A OWNED BY deca s
v ACTUATOR ASSEMBLY _
(Jf bolt tightening is required, list torque PROBLEMS FOUND/ CORRECTIVE ACTION TAKEN: Identify missing or defective B f
value used and reference.
]Nn o, N O f l IE S h
MfA Lm ll_f %4mE] sb LY L.N 0 T. _' o,
)n.
Y, 0 --, -
y(
ex
(
,M, l$
JA
- Mqs Yedfn-0 f// ) n d d '_.
km J
f HRENCH I.D. No. /JG 4'O O
_0MNED BY_M[O A4 A MPl PERFORMED BY b
A 1 87 WITHESS///
' d N h:
~
CEC #. Q.C. (Oept.
"~ CECO.Projectfonst.
,-,,-...-_._m_
7/ Z [$ L
. INSPECTION DATE F0?.M i SRV
~
BOLT LOCKING HARDWARE INSPECTION FOR MAIN STE G 3 34-0 M 6 3 ~7 94-O(> - c>o48 VALVE NUP3ER
/-/R 7 /. fd /W A
_ SERIAL NUMBER Crosby Valve & Gage Company MANUFACTURER General Electric Company SUPPL.IER (If bolt tightening is required list torque PRO 3LEMS FOUND/ CORRECTIVE ACTION TAKEN: Identify missing or defective bo value used and reference.
8sfaco
(/) Sef gocc'a). l nj/45~'
' ~/N ^
b$i.
A s/nno 17 D < ore
/ z~
si N /$<>$'
em i e 't 03 $
L~
C. No t'
-- ir b -
e AJ a o
/
sx S acceoA/I fn h f/>s n
< <> 5 l
in $
d l J d >
et
/
s
<-k $ k e b sur//e
-<.dMc/L- -n c/
cLJ j? cc7&//<
'//r /-A. /[<
c21. o tL Add
.)
/
V C/dceiC!
/
F-=
- M
/ C" C
/' ~
, d.b'd
' bdd dr// b '?" Y dus/ Dc.
.As -s us d
9
& e, n,,
p.scX l
W 4 &.-
l CV k21DP f& -
,)eQY/f/ / /,*'f 8 bR /4f CNd'sKA17 3~5 r}/LD C f
509 2 M _0WNED BY_
- /7'1 W WRENCH I.D. NO.
N m
/
7'7
_ITNESS/,)
/2 g
%-j[...
W
.C.Dg.
' ' CECO.
PERFORMED BY Ciosby Valve & Ga'te Company s,
INSPECTION DATE FORP. # SRV BOLT LOCKING HARDWARE INSPECTION FOR MAIN STEAM o
e yo
/ -S2/- /~0 /8 O SERIAL NUMBER 1/ c 3 7 94OOe-- do Ao VALVE NUP3ER_
MANUFACTURER Crosby Valve & Gage Company General Electric Company SUPPLIER J
i (If bolt tightening is required, list torque PROBLEMS FOUND/ CORRECTIVE ACTION TAKEN: Identify missing or defec'.ive bo value used and reference.
ace 6 d' 0 SY sci,a r
& c -,L.Z~
a n ocem nd&- -
3 w wA.
s%W n
so/e,,a!,-
i o f. g i ade.
aw
.m w u,,1 n / /,%,f"5 po u ~ /
G <r/9 A ~ L /</ J. A. / ~ c U n o=e o n A M u
O
[/1 b
%. Da, u E &.A%.k/l 6~A WI
~
i x,9 ' PA.c.i7?.adia.
/
Cvas)
~
,m CY L o t k L a I R d ry
/
y
{
/
- 4, i
.~L 10 ff~lls Y
- ke T v o c.
awe W/f/ B' C
()
4 a;: L % 't-3 ~
cuo ac.
wRENCa I.0. NO.
my es ; >
-0WNEDBY[6/B
,#)//LN Sor c xA a
'l f
,_ WITNESS ///
eP/'-
[/ e l k r wx CECO. a.'-
PERFORMED BY~ Crosby Valve r Gage mphny
['
INSPECTION DATE FORM. # SRV BOLT LOCXING HARDWARE INSPECTION FOR MAIN STEAM RELIEF A/45 770-og - dd63 VA'_VE MU!GER
/-# 2/ - p: d /3 C SERI AL NUlsER MANUFACTURER Crosby Valve & Gage' Company General Electric Company SUPPLIER (If bolt tightening is required, list torque PROBLEMS FOUND/ CORRECTIVE ACTION TAKEN: Identify missing or defective b value used and reference.
0 bs pei Y
, re./
0 C'r A Fu][
$' Aow> tin o/
h 4.ouL
~
/s A?,k col L d.G/sida
<.u o, !
/
y q-
- Ailr 7h/st-va vih.,~,%
y n
LA 9 p m > e --
nn kf9M//7odEd N
/ si[ n>Ad//BA 3 0
awl n o'. n AL /u /* A 7-7 Tt V
md lm a srz-W [afe l) &
L A S D.
sYoW! f6S/T//d8/7
] OlE4W $
$ Nde N AD bs tk unit 6p &.
1-24) fs/gu Y l$'h
- an. c-a-a u o
'n'?.ENCH I.D. NO.f M 2-IF -
OWNED BY__
$r b%b.
_ WITNESS / d 7'..Ib CECO. Q.C. Dept.
PEP.F0P.MED BY~ Crosby Valve & Gage" Company,
' INSPECTION DATE 7-/-6 R_,
FDP.M i SRV
~
~
BOLT LOCKING HARDWARE INSPECTION FOR MAIN STEAM RELIEF VALV S 4S*
SERI AL NUFBER A/ d 3 796- 00-oo - 7 7 VALVE tiU.3ER /-82./- / e/S /)
PJJiUFACTURER Crosby' Valve & Gage Company SUPPLIER General Electric Company (If bolt tightening is required, list torque PROBLEMS FO.UND/ CORRECTIVE ACTION TAKEN: Identify missing or defective bolt
.alue used and reference.
Gc c en 7b dL.
.. Sr i-sess e<> -
Ards/ b~Y
=c4 wasO aL S e u A ~<br~ e.ci d 5
/
i-7o(-. aiuO eN - re/e,q d cecc
,, 4,c e c/
.m
,oi
.i
-?]/9oJ J h;e-s-r G
e (1/ w "N /* a r~ r C'
s/
(,0>-r*<.,
Apbe-c.,eioal
~C~~ fn A -//
$ aLU d'~
/~ },.a soc ' L,) aceeAAe
.u -
i W Off f e --
k E
- dic o be b // r A.) (
-~
o-i%d G 6wf f
.a b/co $C
,as, CU - b4 G=>
LiW l " ~L [ =. O 1 L..n - r u,r> J n egas s u u kso a fr k s~ 6> oc &
w e L.
.> P C O
/L n.2~
1-7 'T %
F S29'7-LMI WREtiCH I.D. No. rV/ ves z-N4.
OWNEDBYC.640 mM
/edbb F7 %
PEP.F0?.MED BY // 4 hw.
WITNESS CECO'. Q.C.UDept..
Crosby Valve & Gag CdJnpany
7-2 T U
/ INSPECTION DATE
)
F0E-t SRV BOLT LOCKING HARDWARE INSPECTION FOR MAIN STEAM RELIE O296*
l-/6 2 / -b / 7 $ SERIAL NUMBER /!d3790 - CO-0679 VALVE NUMBER MANUFACTURER Crosby Valve & Gage Company General Electric Company SUPPLIER.
(If bolt tightening is required, list torque PROBLEMS FOUND/ CORRECTIVE ACTION TAKEN: Identify missing or defective bolt value used and reference.
0 CY & s er )
G&e r) h
~
- ] o-(A)9W QMdd>/D -zeida t
Y l
>N cw pletb Q f >i Y'~m:<
1'
.h
'Aix c
t si ses/n iL, c.sc.e Rt. l'}f'N L
,, t.
- w A n' 4 7k l1 D wE-rf L.A G=1.11a-B' TbAt.f//d' 4 Nd6N6F [0 STlt.&
V ).a c/<~
art /!,PPf/JQ oA' A y /)? (77 tipQ^ #
7#7-N> _
/4 fw m
_n s/A
//js 6 A
1 rh/d neM ~
- < %,. s
~
v'
/
w/sn?cs.
er @ n A-W7ke e.c.
/
Yd~fd* gye sl V
l#
us-g. 7-M-t 7
~
0 1
//A 2 - E
_0WNED BY WRENCH I.D. NO.
PERF0P.".ED BY // g n,k*
- WITNESSl d UQ 7d.DL
~
CEC %'. Q.q) Dept.
Crosby Valve & Gage'Cbmpany
7-/- so INSPECTION DATE_
FORM p SRV L
BOLT LOCKING HARDWARE INSPECTION FOR MAIN STEAM RELIEF VAL i;
a cs-VALVE NUPSER
/-- 8 7/- /~o / J 4 SERIAL NUMBER /! c 7 75 -co 00'7 /
j MANUFACTURER Crosby Valve & Gage Company SUPPLIER General Electric Company (If bolt tightening is required, list torque PROBLEMS FOUND/ CORRECTIVE ACTION TAKEN: Identify missing or defective bolt lo value used and reference.
G5 n S, se,,6 okl $n d.
accop al?.Cn f
G
/ c, C
.,osL.,.
N to L fi~
a,ck sf mead 6~-
or r
_. w -,, o J
~ d' A-l3ee& /Lo-f i s.. 0 L
e l !' e 4.
A. J rs. u c-co~
c 3
v c.a/s ca Da'~
ci> d d m
,/., c o 2 >c e f L
. ; a. J wa
-. / a a - ~ 4 L.
22'5 de / b j i
L7%l e/ C m'b-5
_a aE/
cc-o a A
di AuL l
C's Pd as et N&KE.o
,,, rs r o s i 7*i asa 1'o u n E t' Mdsk's p
~!?-1k't.
Aca W
-_ -) i /! f*O.
I
_0WNED DY (ECb /na DSPI WRENCH I.D. NO.
m.s o 7 L WITNESS />> [ j b2_c2 7 ' }
'2--
PERFORMED BY_ ///e/
CECd. Q.C.VDept.
crosby Valve-&
Cds.ipany.
7-
7~ae INSPECTION DATE F0TsM f SRV
~
BOLT LOCKING HARONARE kNSPECTION FOR MAIN S SERIAL NUMBER //f 3 79o -oo
,n //o VALVE NUMBER _ /'/82/ [d/M Crosby Valve & Gage Company MANUFACTURER _
General' Electric Company SUPPLIER (If bolt tightening is required, list torque i
PROBLEKS FOUND/ CORRECTIVE ACTION TAKEN: Identify missing or defective bo value used and reference.
IQo SLonk R oW Sn>>,,m d
XAUpeck n / fN Scipl-E>
cm wh
.egerVea& f mnwsv.-f ^.
Tab ena lE do Aco s n i hs,=_
d~
af
/~
A 0
.M' 9Ax.,
k-Ce lm i e sI 4/ f.4%
g, ~ i s it 9->. u k t as.ea 9,h/r2-4440 &&
,. u 4 3~O f7'/LBS ')'Laash' Chd4:htff) p/nff? 0Ss *)~/n ad'A Yb /2 YMS wa s m'
7-7-h. 8 m c) b erc/ - cl:
is/It& VD d N W N '/ c K C -.
xSL,,Y m
a as] s's" N W ~/4-7
',J
-n ec 7z.
so, As 7l7/7L W
t/
/l/8 - 7 ~.4 E't -
_0WNED BY_
WRENCH I.D. NO.
WM )f7kh
._ITNESS h 1 PEP. FORME 0 BY // )sk hw L,
W CECof'Q.C. p t.
s
~ Crosby Valve & g g'6JCompany,
a
U 7['/[8Z,
^
. INSPECTION DATE FO.RM, ! SRV BOLT LOCKING HARDWARE INSPECTION FOR MAIN STEAM RELIEF. VALV (b ~32 d VALVE NU.3ER
/ 87./. Ad /3 /-/
SERIAL NUMBER
/M d 7 794-ck/- 00 4 7
)
MANUFACTURER Crosby. Valve & Gage Company f
SUPPLIER General Electric Company PROBLEMS FOUND/ CORRECTIVE ACTION TAKEN:
(If bolt tightening is required, list torque val u,e,__y ngt e g [ den,tify ingGpf,ec,tgb ijgkgg hgd
{
f
./Q s?-v.~ d. c k
~ q 7
( D u.s <- m.
, p g.
w e d,i v g s-ri-9' D. g 46 n) c/m 7 g. y.ga
/M/S m e rYi W Src~ se 2 fm el nu IS T m e.
~
c ! *.S e$
c c s'e eh
< brno o
arN ma. L
/'ef'enla h-r M -: o u e w
bs' cal b
& l-o e n,rc f n a%
A ft ',
CZ& 24:
x, fdb k />o-d f/, n 1,
^~'L' 6
[d n1
^
I Dh
]
L.
~
w. 0 hl, 7lzl? L Cne Lizh7-%'s u l=u Tx 7-/9%.
de J'l' fos /7~tn242 %Mut {Nd&ktO
.S ~o f 7 b' R S 'l $ o N w sl. '
I2//RGD dd-e eC7' 9 '7 'T %
. fd ws m%
osd; /ilvt N 6
V' de wa s> W i
7/7/ N tt.
a s >->--
m ho9a,
.?/ C P A b fc =-. ' --
elr ; - ~5
h 55R/
u.ca. 7-g-g c_.
t
'6 4
/[A 2 -E2 -
OWNEDBYM WRENCH I.D. NO.
W:TNESS/d IT 7"7 '7L
)A l
PERFORMED BY CECW'. Q.C.pept.
Crosby Valve (i Gag (fompany.
l
. INSPECTION DATE 7./-# f FORM # SRV BOLT LOCKING HARDWARE INSPECTION FOR MAIN STEAM RE
/-/82 /- / 0 /J[
SERI AL NUMBER # 63 ~7 90- oc - o o /, 5
~
VALVE NUFBER Crosby Valve & Gabe Company MANUFACTURER General Electric Company SUPPLIER.
(If bolt tightening is required, list torque PRO 3LEMS FOUND/ CORRECTIVE ACTION TAKEN: Identify missing or defective bo value used and reference.
AccepY '
r1 s c s' r tr M -
ArE es,G.
-op/,,c'e
.5 '
C.75
- b. l rije C $
e
/
f 3
& / ~
- ,/.
m i'-, -
a 4:
s lIY c fc -
k w cl. e d r i -
ce e e e n Y o /I l -
/
N) fus&
Co Prhrs V Loch o A7 2 fuc>T7v6/2 Yo M u S chuk&D
~
y a-y I. J t (L f-H).
3-3-]2-h L f y
E8b WRENCH I.D. NO.
/M.fo 92.-
_0WNED BY 6 (40 m 'h
. WITNESSid b/b 7-7 -D L.
PEP. FORMED BY 4/g/kh__.,._
L,
CEEo. Q.U. Dept.
CrosbyValve&Gjg'elCompany,
INSPECTION DATE 7 / - 3' t.
FO R".
i SRV
^
BOLT LOCKING HARDWARE kNSPECTICN FOR PAIN STEAM RELIEF VALVE l
G 70*
A/ (37 7 c -n
- ~78
/-42./- Fo /3 d SERIAL NUP3ER VA'_VE NUP3ER MANUFACTURER Crosby' Valve & Gage Company General Electric Company SUPPLIER i
(If bolt tightening is required, list; torque j
9ROBLEMS FOUND/ CORRECTIVE ACTION TAKEN: Identify missing or defective bolt locking ha value used and reference.
On n%d$cs T.5-4 c -sm ;
,C,- e / ace-o to6tu
-i a/
o ; m i.- c r s w e c.
@ & > h-(A 3
i u. n a c L. /~ d.
is. ~ : n // / <-~ s s u n t,n,/ac/ - o, /. t f'<. /G M -
sL~,l 0, en
. dn u
/ $
x ZI /dr neea o /Wi2s--.
&, d l $ft '-
L,elnux..L b b u c/- ~
/
/
l.
la he,' /1 c~b F7~htLs I L o&
n > 1~6 ' f6 c i Tios4/2 75tt 9u s S HkK6p
$f,A7-7 ' s i f e-p
.sn c. wA*.
uRENCH I.D. No. 44 "+6 OMNED BY f 6 A C.A'1 N DGPI k.
WITNESS ls) d/M 7 -7D. 2._.-
~-
PERFORP.ED BY 8
me 4 Ceco! Q.C.(Dept.
Crosby Valve & Gag oinghny
~7 'L I I--
FORM f SRV
, INSPECTION DATE BOLT LOCKING HARDWARE INSPECTION FOR MAIN STEAM RELIEF V SERIAL NUMBER 47796-oo - o/87
/b2l-FO(3b-VALVE NUP3ER MANUFACTURER Crosby Valve & Gage Company General Electric Company SUPPLIER (If bolt tightening is required, list torque PROBLEMS FOUND/ CORRECTIVE ACTION TAKEN: Identify missing or defective bolt value used and reference.
& -T.sf-G Ec~ rij kreen*Ib bD.
( $'
'f& /-.
->,* x l sN
.^ w f
'S r.10:} h e oW
/
f 74:
AsA~J
e h,
_ ITNESS W
CECW Q'.C.
pt.
Crosby Valve & Ga C6fnpany.
~7-/- 3 7-INSPECTION DATE FORK f SRV BOLT LOCKING HARDWARE kNSPECTION FOR MAIN STEAM R c er po f t NI
-SERI AL NUl6ERf (S ~770- co - co-77 VALVE NUPSER
, jy -2 / -
MANUFACTURER Crosby. Valve & Gage Company 4
General Electric Company i
SUPPLIER (If bolt tightening is required, list torque PROBLEMS FOUND/ CORRECTIVE ACTION TAKEN: Identify missing or defective bol value used and reference.
, C..s,,,,, oce,,7"s tfL S
6.,cd-e.,so ~' & = d sl.y 4? Q f-s-r
<c an o s f 'S /ts
~ -J Gits se cy 1
L f
'f. m4-u.<suecs 7 O" M ff* WW' (~W O.cc Q 4CI -
W*
tG u es o'
.w.
c.G w
.?)
A D/16) 7'c'S-a/es/-x i y 4 g,,' g,.'
g(,,, p,.(
/
f M cc o e s / /,
A.) ~/ h 4 eiwicl k ond c<, / ci e,2 uwL
/
/
v'
//*.'<t>//c/.
/d w2 coec.C.
f'w werl
/7eri 7's~ S. a) s k ~
a.
'7~~ b 6-// s a m
i,03 G f/pd-mn W.
We.
A e b eroe W
0 to. 4 -Kr (s-) ad/ ard~ $/wa m./d ac<-s7%f6 -
l)
[
id.i. b&
c f8.' fB.S / / /rs'6/2
'T~n 29 v'& & Nf64~6D Th fTb2 O' LM W tlCO+Y Y1 u
_D/ l? S D i
I
- ( e
'7 5 -(t.its) 14 reyc - cd s/g 2
,an m D 6 t'].-
l WRENCH I.D. NO.o-So N Fw. co7
_0WNED BY c h we./2C.
4::de, ',
c-,
i c.4 e/s 2.
laJ b42., 7-7 Y2 -
// /:k erw e-lA.
WITNESS
~
CECO # Q.C. (Dept.
PERFORMED BY Crostiy Valve & Gage Ccqhpd6)
-7
7k!b
' INSPECTION DATE ORK f SRV BOLT LOCKING HARDWARE ENSPECTION FOR MAIN STEAM RELIEF
/ -d 2/- #c /3 A/
SERIAL NUMBER ///$'/9d - e o oogG VALVE NUM3ER MANUFACTURER Crosby Valve & Gage Company SUPPLIER.
General Electric Company (If bolt tightening is required, list torque PROBLEMS FOUND/ CORRECTIVE ACTION TAKEN: Identify missing or defective bolt l value used and reference.
b
!:7^~.<'C A*e-In
~ / Z, b. m i y. c s s n <<
As*6A
/> > i
,7 JL) < pe C !
- c rw
,o U/ bv1e Y h sccsl~,
jned b~
$~/
_ <evt nE J>/
A%
n lo /.
b mc! f~, -,,,'-
<-r-f TJ n > a.<' N
~
/[ /z ca L b_cdk c-,/ ~,Z-Y ki
. n "/
,- m,n l, 1~o d
,l' N W" Md lrw I L.
+
taAs,. L vie ;d7-m 7 '1*'
da 'fo* rn us &f/d;akEO [OWlL&S i.1
,r An~h WDJi?~/c 0
G CYL o c k LJ/RG D d & d
~7~
aY* rmmAle Y
/?s.<-]"l~r
,Al ae 7 7 /r z... J aiscaicii a Ink 12
/
as.r. A,A
?l7/57-A.A._ i wa:. d e z;~'
J to ft.-/4ac J up-e. 7-n 8 '
d 0WNED BY WRENCH ~.D. NO. M/9 - 7 2 -f2 -
PERFORMED BY. d)gh wk WITNESS M 7" 7N S _
CEC 6. Q.C.yDept.
CrosbyValve&Gaggoppany.
7'/~8cb Y # SRV INSPECTION DATE_
BOLT LOCKING HARDWARE fNSPECTION FOR MAIN STEAM RELIEF VALVE 44 G P # d C0 7.5~
/ #2/-hePO -rs #
SERIAL NUMBER VALVE NUtGER MANUFACTURER Crosby ~ Valve & Gage Company
~
SUPPLIER General Electric Company PROBLElG FOUND/ CORRECTIVE ACTION TAKEN:(If bolt tightening is required, list torque value used and reference.
Identify missing or defective bolt locking hardware.)
L S Y A7 dea) secM ioSGn h
W,n&C M a>cel cA O @L(N.
. </ l/ -
A s b x:v hb"a }N
/bd--
clM <<
_A
~
scs,~ i i th l.
J f
bbl
-w!
o/
/sn s
no 7; /0 h / - / $5-.
& s// # ' b' -
A / n n J
f occ.J h ~
/
y gs l
g:o.c./hwz,.
- 7-t-5 L.
uiR.gD V Th/2.Sa s c,)fsz/Je r.o G fT/t as s n f '. I'o s i I l u t R Loik f)G flCl D /d3 fESTED W!) 91-.W
.ff.8._El G 9 C G Co i
P GIV WRENCH I.D. NO.
n 't 6 ~0 'T ~l.
_0MNED BY W O Am I ek k w WITNESS /4/
M/w 7"'7D,%' '
PERFORMED BY CEEo. Q AC. Dept.
Crosby Valve & Ga C64?any 7[L/92
's
, INSPECTION DATE
'(
/
,g
~
BOLT LOCKING HARDWARE kNSPECTION FOR MAIN STEAM A [ 3 796--oo-#d-7 A
~
/
/ h7 l' hI 3 b SERIAL NUMBER VALVE NUfGER Crosby Valve & Gage Company MANUFACTURER General Electric Company SUPPLIER (If bolt tightening is required, list torque PROBLEMS FOUND/ CORRECTIVE ACTION TAKEN:
defective bolt locking hardware.)
value used and reference. Identify mis 0
.<,-t
.s c c h Seb iLd dEcb s
C.b.ux
-4 1. M s8/r//
s,.o )c nr>de
/ r,
%f AL/J oLJ V L j.
/
~
O
/
'b ' Tob
- q hKH6At< [ //r k c & [
j
~
Y ^ /1Jo's-JkW f-6lL
&&h
- w a. u ya.
~
f
.v l
p
- [ : _- -- 3 L j E, l-L,~1L & ~ JQ%
7-*)f*%)
t/Jm A tu.&el, 7/2 /f 7-7~2 A 1 M A C / k & m n/M Psss7'/os4W
' ~~
f 7%ns >'Luk usw w "> ?N1-c Y
k &) f/erwe m/
50
~/ 5 $.
4) k ~ b sw/7$ '
~s y N
/d Mh gy,,,[
,yj fg 9'a [
7/7/gr z L
AO 7/7/t co r
/
M "' 7~ E
_0WNED BY WRENCH I.D. NO. -
. _ WITNESS /,< )
7e74.5"
/7 A
awte +,
m, CEC Q.C. Djfpt.
PERFORMED B.Y Cro'sby Valve & Gage (ofpg.
p
-~---e be INSPECTION DATE
/ 6 2- -
FOR'M i SRV i
BOLT LOCKING HARDWARE kNSPECTION FOR MAIN STEAM RELIEF VA G do' VALVE NUM3ER /-d'4#-/~o/3 3 SERIAL NUMBER)/ 6 3'79 - do - oo 7 6 MANUFACTURER Crosby Valve & Gage Company l
l.
SUPPLI$R General Electric Company (If bolt tightening is require.d. list torque PRO 3LEMS FOUND/ CORRECTIVE ACTION TAKEN: Identify missing or defective bol value used and reference.
4 n
s..-r. < s, -in =
a cenn/L.
k3 9' 8 -
V/4 -dN/L -
wf in s/.-6 ra-n L
</
, w, c. e Au,,,,,,
~7 % e
,-n he s-7'~ <.o ;a /, h -
~
J' WJ C 6L scesito6L -
'Smt wmc L
- i o n. & /,,, s. d a w n/so/
c-1 d dk/t, a n-h,n a < /. c-nann /.
<. a ~
to -/s. As #
0 0
c. p l /,} G /m d u O c.n n ; / J o e c p / &~
c-1
$8a'.
i a -rf Poc /1'n asn Youa cNtok60 rnkleni4 bock t
w n.
_. P e C7 a e.e u v7' 1 -, -4 u i
i i
i pr$baw.
OuNeoBrCtso
/h m DfP/
uREncu I.o. n0.
PERFORMED Br ///d.Ik bM.h.
WITNESS /A) M /m 2 7-)- h CECO NQ.C. Dept.
Crosby Valve.& Gagyoidpany
INSPECTION DATE
[~ L '~ 0 BOLT LOCKING HARDWARE INSPECTION FOR MAIN STEAM RELI VALVE NU.GER / b 7 M -
O I 3 bd SERIAL NUlOER ///3 794-v(j -
t/
Crosby Valve & Gage Company P.8""eACTURER General Electric Company SUPPLIER i
(If bolt tightening is required, list torque PROBLEMS FOUN0/ CORRECTIVE ACTION TAKEN: Identify missing or defective bolt value used and reference.
dh (h (d Scee.uj Ge 6
[b h ia.n ii d,
c/ 7-d. ml]
.2 wL' rod db So/~'i };,
8.~w (&
m
[Wlg'7 Nr-> :t N
4: L 7/s/ss wn w
h ___ p M E d u 7 s.v a.
sr ?~s. he s#/iEtA 7h/2 fat
&AWsAsa'-4~o f7}U1s YJocA-w a.
_ W/ A d-Q fiddtf
%)~?lL sd.? hec N
bseabl~ d o->-1.
/k*7 ecmobbe el Y 7/2/7bs/Aulad Y
a n 7m
- c tv1
- w. A v
A G-
/ dons w j-y/pyAr&
d 4:* b & O,
cl7 4
J
//8 - ? P 2.
_0WNED BY WRENCH I.D. NO.
h 7"7-Y 1 f
PEPF0PJ'.ED BY dl/bM,k.
.WITNES Ceco,0.v: cept.
Crosby valve a ge Company,
~
C
' INSPECTION DATE 7-/- T 7-FORK i SRV BOLTLOCKINGHARDWAREkNSPECTIONFORMAINSTEAMRELIEFVALVES
/h2l" kOl3 SERIAL NUMBER 83 @ Po -Oo do 7 O VALVE NUlGER MANUFACTURER Crosby Valve & Gage Company SUPPLIE'R General Electric Company (If bolt tightening is required, list torque PROBLEMS FOUND/ CORRECTIVE ACTION TAKEN: Identify missing or defective bolt value used and reference.
. < - JY d-ebt
/ms;u ce bl m
0
% f.cerca) o,1el S~ cl -
OCces &/I 8-soe;> /e/.
.~
) /s/-
/ tis.s-A NEc.OL $
,i
.4bmb&
ncl.Ae6 $bw SM f.
5.0 cl~
. a n. ci t i o
h GY ez/
JLDS h
n&Le/
L 7 -
s.
4 4' b, b ai n e ruinua na ris r i Hs ekro Go fr/.rs /9)~o w nwW
.L W / lt 6 77 W
/
WRENCH I.D. NO.pr7 ar f L OWNED BY l- [ 4 b
/v) /71 MM/r r
.57173 )fA 4
7-7 *',.) 5 PERFORMED BY ////..
u.
m.x b WITNESS /A)
U
~ Crosby Valve & Gagp Company CECO. WQ.C. Opt.,
7 / h l[1-INSPECTION DATE FORM # FCV o
n
.BOLi LOCKING HARDWARE INSPECTION FOR REACTOR RECIRC FLOW CONTROL VALVES VALVE NUMBER / b 3 $ - hO [o O ASERIAL NUMBER 1/- E O MANUFACTURER Hammel Dahl Company S PPLIER General Electric Company i
(If bolt tightening is required, list tor Identify missing or defective bolt locking hardwa PROBLEMS FOUND/ CORRECTIVE ACTION TAKEN:
value used and reference.
i o.t A(3 P. @
Yo K& l BoidNGT Bourtacs J
-Qo(o (1-i 8 s.,
3 LMS P. vJ/ 60,< wtz G tl eM :
nro Aeoa esWs voualo 4 L nis P. @-
kcifa Afo /L/ 2o e & Bourt46 Bo O ff~ LAS., 4 L^l.S P. d { 80 y &K G ^l c4 :
slo Peoa Ls41s fo a ND Acifu A fo /L ilo a to s1 e a w6 do t rid 6 - A ul-LNS P.$ /do ff-l t$S.,' No hto at 6/45 fou &D L c:fa Afo /L Bo urt a6 - 3 pat /Ls of Po.strt osf
$Ho L CA 10 tL 80 L.fS ML $ S L d 6 LO Cd<td i K.G.S *,
Af f L. A &G(.)
- 1
-('o./?Q a & \\{hl u 6 ftff. - /6tJoo(L LolSTR. MAhluhLj d [k3 h. [M I
I'b l 3k $
OWNED BY [b)Mf l
WRENCH I.D. NO.
WITNESS
/
7'f -J 2
~
Ceco. Q'.C. Dept.
PERFORMED BY Ceco. Project Const.
- Bnr f tcyma 9s S 6HGCKG a VJ/ HM 6f,f.. ] l@
f f,, l LGal g$;
ff YhI k * $l Y f 00l T8
'l
_m INSPECTION DATE O
[p YM FORM # FCV BOLT LOCKING HARDWARE INSPECTION FOR REACTOR RECIRC FLOW CONTROL VALVES VALVE NUMBER / -d33-0 6 0 d SERIAL NUMBER 7 / - 2 o O (- 0 01 A l
MANUFACTURER Hammel Dahl Company SUPPLIER General Electric Company (If bolt tightening is required, list torque PROBLEMS FOUND/ CORRECTIVE ACTION TAKEN: Identify missing ~or defective value used and reference.
Io Ld.SP. h-10 54 6 { Bo n 14 2-c Aourc d b 6(al, $14d S.
3 L US P ud/ r$o X y) LG N c H '.'
No Pie ost-ce b foa N o.
Lefu two /L / Y o K & 801-.T L NG - 4 Ld5 P. 8-30 0 $1'-LB5.
4 L^f3 P. dl 80X LNd M e M '
Mo PKoBL-G rd F'o v d 6 AC:fd A1'o K. Lo O Cott PL.E d6 Ao11t si6 - A L L.
\\
L MS P. (4 I 6 0 ff-Ld 3. t Nu htoa L-G t1S hed A!0 A c,1'w A T O VL 8 o L. f L db '- A L-L Lo cKs)L tLG S W$$bfA L$
-fb t?A u 6 t/gL u 6 it4f jdda o /L LMSTR, MANIAAL-WRENCH I.D.'NO.
_(- N[o I N Y _0WNED BY [A /d kb [.Nd b.
(([b WITNESS PERFORP.ED BY CECO. Q'.C. Dept.
Ceco. Project Const.
,-.._,m
...-m.
,____m.,_.
1.
Revision 0 June 30, 1982 LASALLE COUNTY STATION UNIT 1 t
STRUCTURAL BOLTING TIGHTNESS INSPECTION PROGRAM F0R CONTAINMENT VALVES i
f.
. E. PALB PREPARED BY:
E Project Construction Department c
' REVIEWED BY:
e 2 A k-D. L. SHAMBLIN Site Project Superintendent l
AP' PROVED BY:
c A b.
be B. B. STEPHENSON Site Project Manager G
4 l
e 6
,.7--
~.. -,,
n
~
l, LASALLE COUNTY STATION UNIT 1 STRUCTURAL BOLTING TIGHTNESS INSPECTION PROGRAM FOR CONTAINMENT VALVES SCOPE This inspection program will be limited to safety-related valves inside Containment
~
and will consist of the inspection (and correction if required) of:
1.
proper tightness, or 2.
proper installation and condition of bolt locking devices-(whererequired).
for valve structural bolting essential for the valve ' function relative to sa'fe plant l
shutdown and containment isolation.
Valve pressure boundary (bonnet and packing gland) bolting is not included in this' inspection program.
The containment valves involved in this inspection program are separated by valve function as follows:
1.
Manual 2.
Motor Operated 3.
Air Operated 4.
Testable Check 5.
Main Steam Isolation 6.
Main Steam Relief 7.
Reactor Recirc. Flow Control For the valves included in this. inspection program, mounting hardware for external valve position indicator switches will be visually inspected to assure bolting is loose bolts will be noted on the tight against lockwashers or mounting bracket; inspection form and tightened with ordinary hand tools.
(
I.
GUIDELINES FOR BOLT TIGHTNESS INSPECTION Manufacturer's recomendations will be used for spec. torque value. Where a manufacturer recommends " wrench tight", the following target torque values should be verified:
BOLT DIAM. (in.)
TARGET TORQUE (ft-1bs.)
11 5/16 47 1/2 5/8 94 3/4 167 7/8 270 1 1/4 808
(
Reference:
6/28/82 B. F. Pandit letter Attachment "A", Page 2, for i 15% torque wrench accuracy.)
Above target torque values are for ASTM A193 B-7 material.
If " wrench tight" is specified for a different bolt material, CECO. Project Construction Engineer will request applicable values from CECO. Project Engineering'and document this infor-mation on the inspection form.
Limitorque operator mounting bolt torque should be verified in accordance with the above requirements or the following values, whichever is less:
MAX. VALVE ATTACHMENT LIMITORQUE '0PERATOR SIZE BOLT TORQUE (ft.-lbs.)
SMB - 000 16 - 15%*' =
i3 72 00 85 - 15%
=
119 -
0 140 - 15%-
=
72 1 15%
=
119 2
140 - 15%
=
190 224 - 15%
=
3 595 4
700 - 15%
=
629 5
740 - 15%
=
Where bolt access prevents use of a torque wrench, the bolt will be inspected (or tightened) with the use of ordinary hand tools by the same person 'who used This procedure will be followed without the torque wrench on the other bolts.
interruption to assure the workman has an accurate sense of the amoint of force Use of hand tools he has to apply to the hand tool to properly tighten the bolt.
should be noted on the inspection forms.
- max wrench erro,r factor
~
- MANUAL VALVES Valve yoke / bonnet bolting for. manual valves is only safety significant for valves none are located inside required to be closed for primary containment isolation; All manual valves in containment are provided for maintenance or containment.
A yoke failure on these valves would only allow the' disc to back seat test purposes.
and cause no significant problem. Therefore, inspection of the operator structural bolting 'will not be required.
INSPECTION DOCUMENTATION:
none MOTOR OPERATED VALVES (24 valves total)
The following motor operated valve structural bolting will be inspected for tightness:
1.
operator / yoke bolting
~
operator assembly bolting essential to the function of the motor 3.
operator assembly - visual inspection to assure bolting is tight against lockwashers; loose bolts will be noted on the inspection form and tightened with ordinary hand tools.
INSPECTION DOCUMENTATION:
FORM # M0V AIR OPERATED VALVES Yoke / bonnet connections are of a single casting and, therefore, inspection is not Some of the valve designs utilize a bonnet extension piece, which is a pplicabl e.
part of the valve pressure boundary and, therefore, outside the sco structural bolting inspection.
l diaphragm housing and, therefore, inaccessible for this inspection.
l INSPECTION DOCUMENTATION:
none l
TESTABLE CHECK VALVES l
The air cylinder actuator is provided for test purposes only, and should not affectThe the operation of the check valve if it becomes loose or jammed.
of the actuator bolting will not be required.
INSPECTION DOCUMENTATION:
none I
MAIN STEAM ISOLATION VALVES (4 valves total)
All actuator bolts have lockwashers, with the exception of hydraulic cylinder tie-rod nuts. The actuator bolts will be visually inspected to assure they are tight against their lockwashers. The tie-rod nu't torque will be checked in accordance with instruction manual requirements.
INSPECTION DOCUMENTATION:
FORM i MSIV MAIN STEAM RELIEF VALVES (18 valves total)
All bonnet & actuator bolting (including air cylinder bolting & solenoid valve' The actuator mounting bolts) are either lockwired in pairs or have tab washers.
arm bolts have lockwashers. All of these bolt locking devices will be inspected to assure they are installed, installed properly, and are not damaged. This Bolt inspection will be directed by the valve manufacturer's representative.
tightness will be checked as directed by the manufacturer's representative, for All other only those bolts with missing or improperly installed locking hardware.
bolts with locking hardware installed in acceptable condition can be assumed to be factory tight since the valves have not been subjected to operating vibration loads.
INSPECTION DOCUMENTATION:
FORM # SRV i
REACTOR RECIRC. FLOW CONTROL VALVES (2 valves total)
~
All actuator b'olting significant to the operation of the valve are either castle lock nuts or lockwired. These locking devices will be inspected for proper installa-tion and condition.
INSPECTIONDOCUMENTATIONiFORM '#-FCV l
l i
I
~
r l
4-l
INSPECTION'DATE FORM # MOV MOTOR OPERATED VALVE STRUCTURAL BOLT TIGHTNESS INSPECTION SERIAL NUMBER VALVE NUMBER MANUFACTURER YOKE / BONNET BOLTING (Use space below to diagram bolts not tightened to spec )
SIZE SPEC. TORQUE NO. OF BOLTS CHECK HERE IF NO PROBLEKS WERE FOUND.
t WRENCH I.D. NO.
0WNED BY (Use space below to diagram bolts not OPERATOR /Y0KE BOLTING tightened to spec.)
SIZE SPEC. TORQUE NO. OF BOLTS CHECK HERE IF NO PROBLEKS WERE FOUND.
WRENCH I.D.
N0.
0WNED BY OPERATOR ASSEMBLY PROBLEMS FOUND/ CORRECTIVE ACTION TAKEN WITNESS PERFORMED BY CECO. Q.C. Dept.
CECO. Project Const.
w
INSPECTION DATE FORM # MSIV MkIN STEAM ISOLATION VALVE ACTUATOR BOLT LOCKING HARDWARE AND HYDRAULIC CYLINDER TIE -ROD TIGATNESS INSPECTION SERIAL NUMBER VALVE NUMBER MANUFAdTURER Rockwell Manufacturing Company SUPPLIER General Electric Company HYDRAULIC CYLINDER TIE R0D BOLTING (Use diagram below to identify )
bolts not tightened to spec.
NO. OF BOLTS 4
TOP OF VALVE i
cO O
TORQUE SEQUENCE cross corner
((] CHECK HERE IF NO PROBLEMS WERE FOUND.
O O
WRENCH I.D. NO.
6 A
k OWNED BY ACTUATOR-ASSEMBLY (Jf bolt tightening is required, list torque PROBLEPS FOUNd/ CORRECTIVE ACTION TAKEN: Identify missing or defective bo value used.and reference.
i i
i 9
0 i
I OWNED BY WRENCH I.D. NO.
l i
WITNESS PERFORMED BY CECO. Q.C. Dept.
4 l
~
CECO. Project Const.
l a
p
?-..
' INSPECTION DATE
" FORM # SRV BOLT LOCKING HARDWARE INSPECTION FOR MAIN STEAM RELIEF VALVES VALVE NUMBER SERIAL NUMBER MANUFACTURER Crosby Valve & Gage Company SUP, PLIER General Electric Company PROBLEMS FOUND/ CORRECTIVE ACTION TAKEN: (If bolt tightening is required, list torque value used and reference.
Identify missing or defective bolt locking hardware.)
WRENCH I.D. NO.
OWNED BY WITNESS PERFORMED BY CECO. Q.C. Dept.
. Crosby Valve & Gage Company "..
e, INSPECTION DATE
\\ FORM t FCV BOLT LOCKING HARDWARE INSPECTION FOR REACTOR RECIRC FLOW CONTROL VALVES VALVE NUMBER SERIAL NUMBER MANUFACTURER Hammel Dahl Company
. SUPPLIER General Electric Company PROBLEMS FOUND/ CORRECTIVE ACTION TAKEN: (If bolt tightening is required, list torque value used and reference.
Identify missing or defective bolt locking hardware.)
OWNED BY WRENCH I.D. NO.
WITNESS PERFORMED BY CECO. Q.C. Dept.
CECO. Project Const.
... l l
L