Affidavit in Support of Summary Disposition of Jf Doherty Contention 5 Re Supression Pool Swell.Platform Will Only Experience LOCA Bubble Pressure W/Drag Forces. Prof Qualifications Encl.Pp 52-60
ML20062H479
Person / Time
Site: Allens Creek File:Houston Lighting and Power Company icon.png
Issue date: 07/29/1980
From: Cheng R, Sullivan R
EBASCO SERVICES, INC.
To:
Shared Package
ML19331C559 List:
References
ISSUANCES-CP, NUDOCS 8008190061
Download: ML20062H479 (8)


Text

)

i 4

1 UNITED STATES OF A.WRICA g

NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICENSING BOARD In the Matter of

)

)

HOUSTON LIGHTING & POWER

)

Docket No. 50-466 COMPANY

)

~

)

(Allens Creek Nuclear

)

Generating Station, Unit

)

No.

1)

)

AFFIDAVIT OF RAYMOND A SULLIVAN AND ROBERT C CHENG State of New Jersey County of Bergen We, Raymond A Sullivan and Robert C Cheng, Principal Civil Engineers for Ebasco Services Inc. on the Allens Creek Project, of lawful age, being first duly sworn, upon our oath certify that we have reviewed and are thoroughly familiar with the statements contained in the attached affi-davit addressing intervenor John F. Doherty's Contention 5 regarding suppression pool swell. All statements contained therein which relate l

co Ebasco Services Incorporated responsibility for the design of HCU and f

TIP platforms for the Allens Creek Nuclear Generatina St: tion, are true and correct to the best of our knowledge and belief.

/.

l m

  1. w

,b GW

,w (s sd- >, a a

[/+w "

(2' V

~

j' f

Subscribed and sworn to before me this.) #" day of 1980.

5

[

"> ' s,

J **

CARCL A. OPITENOK NOT/.GY PtJSUC OF.aigni jep3ry MY CCf.'MCION DP!RES SEFT.18, IM1 r, ~ ~ ~

e-S008190061

UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICENSING BOARD In the Matter of S

S HOUSTON LIGHTING & POWER S

COMPANY S

Docket No. 50-466 S

(Allens Creek Nuclear S

i Generating Station, Unit S

No. 1)

S i

l AFFIDAVIT OF RAYMOND A. SULLIVAN AND ROBERT C. CHENG I

My name is Raymond A.

Sullivan.

My business address is 160 Chubb Avenue, Lyndhurst, N.J.

I am the Principal Civil Engineer responsible for Reactor Containment Building Design employed by Ebasco Services Incorporated.

The statement of my background and qualifications is attached as Exhibit I to this l

testimony.

My name is Robert C. Cheng.

My business address is 160 Chubb Avenue, Lyndhurst, N.J.

I am the Principal Civil Engineer responsible for Reactor Containment Building NSSS Interface employed by Ebasco S'ervices Incorporated.

The statement of my background and qualifications is attached as Exhibit II to this testimony.

The purpose of this affidavit is to address John Doherty's Contention No. 5 which alleges that the control rod

drive mechanism hydraulic control units (HCUs) and the transversing incore probe (TIP) may be damaged by the hydrodynamic forces of a high vertical water swell in the Suppression Pool folleving a loss of coolant accident (LOCA).

This affidavit addresses those portions om the contention which relate to matters within Ebasco Services Incorporated's design responsibility for the Allens Creek Nuclear Generating Station.

As the affidavit of Peter P.

Stancavage explains in considerable detail, General Electric Company has performed i

extensive tests to obtain information on the hydrodynamic loads that are generated in the area of the Mark III Suppression Pool during a LOCA.

HCU Platform The steel platform supporting the HCU Modules will be located above the height at which the General Electric Test Program indicates the largest LOCA induced bulk pool swell l

loads have terminated.

The HCUs will sit on a checkered steel plate floor 22 feet and 5 inches above the normal suppression pool surface.

This floor will be approximately half an inch l

1 thick and supported by floor beams spanning between wide-i l

flanged girders approximately 27 inches deep.

These girders i

will be supported frcm the drywell wall with no connection to l

the steel Concainment Vessel.

With this arrangement, the bottom cf the floor girders will be approximately 20 feet above :

l b'1 l

N i

the surface of the suppression pool where they will be inpacted' only by the froth impingement portion'of the LOCA loads determined by General Electric.

Top mounted trusses,will;be connected to the top of the girders in this region to" resist the, load from the froth impingement effect during LOCA.

_These trus'ses will also serve as supporting structures for'the.HCU modules against lateral seismic effect.

Vibratoryresponseofthesuphortplatformwill subsequently transmit a response load to thA HCU modules.

The magnitude of this response load for Allens Creek will be computed by Ebasco in a plant unique' dynamic analysis.

This response load will subsequently be utilized by General Electric in its dynamic qualification of the HCU modules.

Tip Platform The Tip Station will be located on a concrete plat-form cantilevering about 7 feet out from the drywell wall at an elevation of about 6 feet above the normal suppression pool surface.

To reduce the pool swell loads on this structure the

u. p cantilever will be arranged thick enough so that the bottom surface is immersed into the pool; this bottom surface will also be sloped to function as a deflector.

Therefore, with this arrangement the platicrm will experience only the LOCA bubble pressure plus drag forces, and not'the bulk swell ispact. _

k E5

-,,%,,e-,--n

..n-

,+,-e-.,.n...

EXHIBIT I RESUME - R A SULLIVAN d

Principal Civil Engineer

SUMMARY

OF EXPERIENCE Total Experience - 15 years in civil engineering, all in design, specifying, and material

, > -. procurement of structures and components for electric generating stations (fossil, nuclear j

and hydroelectric).

?

~

r Education - University of Connecticut - Master of Science in Engineering - 1965 i

University of Notre Dame - Bachelor of Science in Civil Engineering - 1964 Licensed - Professional Engineering License - New Jersey REPRESENTATIVE EBASCO PROJECT EXPERIENCE

[

Hydroelectric Allegheny Power Service Davis Pumped Storage Project Centrais Electricas Brasileiras S/A Peixoto Hydroelectric Development Nuclear Houston Lighting & Power Allens Creek Unit No.1 J

PEPCO Douglas Point Unit No. I j

Northeast Utilities Millstone Unit No. I j

Fossil Arkansas. Power & Light Lake Catherine Unit No. 4 f

Dayton Power & Light J M Stuart Unit No. I I

I EBASCO EXPERIENCE (Since 1965) i Lead Discipline Engineer on various nuclear and hydroelectric stations. Activities include license and permit document preparations, design criteria preparation, design supervision, preparation of specifications, material procurement, and coordination with fabricators and I

Constructors.

j 56 e

(,

i

' R A SULLIVAN EBASCO EXPERIENCE (Since 1965) (Continued)-

i Items of responsibility on nuclear projects included containment vessel, structural steel and concrete, pipe restraints, pool liners, cranes, elevators. -intake screens and switchyard j

structures.

I 1

Items of' responsibility on hydroelectric projects included penstocks, gates, trash racks, l

cranes. and powerhouse framing.

f Construction engineering for 3 years at a nuclear project site. Supervised erection of structural steel, reinforced concrete, lifting equipment, shielding plugs, pipe restraints, siding and roofing. Riggng Supervisor on main transformer, pumps, motors, tanks, anr1 crane load tests. Assistant to Resident Engineer performing field design and procurement of structural i

items.

Two years as Designer for various fossil stations. Prepared design and drawings for building framing and platforms; intake hoist supports and screens; and circulating water pipe and e

manifolds.

1 l

l i

i 7..

E7 i

GMV EXHIBIT II 1248 Pag 31 of 3 RESUME-ROBERT C CHENG Principal Engineer

SUMMARY

OF EXPERIENCE (Since 1962)

Total Experience-More than thirteen years in research and engineering with emphasis on structural analysis and design of industrial and power generating plants.

Major Field of Interest-Development of structural analysis, design and test programs for major

~

generating projects.

Professional Affiliations-Registered Professional Engineer in the State of New York and Republic of China t

Education-BSCE Taiwan Provincial Cheng Kung University-1963 i

MS, Structural Engineering, Virginia Polytechnic Institute-1965 PhD, Engineering Mechanics, Pennsylvania State University-1972 REPRESENTATIVE EBASCO PROJECT EXPERIENCE I

Nuclear Carolina Power & Light Com' pany Shearon Harris Unit Nos.1,2,3,4-each 960 MWe H.B. Robinson Unit No. 2-700 MWe Florida Power & Light Company St. Lucie Unit No. 2-890 MWe Houston Lighting & Power Company Allens Creek Unit Nos.1 and 2-each 1200 MWe Potomac Electric Power Company Douglas Point Unit Nos.1 and 2-each 1200 MWe Tokyo Electric Power Fukushima Unit No. 6-1100 MWe Chugoku Electric Power Japan Atomic Power Tokai Unit No. 2-1100 MWe GE APEN Princeton Plasma Physics Lab.

Tokamak Fusion Test Reactor ERDA

!.~

Es

/

PIga 3 of 3 ROBERT C CHENG PRIOR EXPERIENCE (Continued)

Chemplant Designer, New York:

Structural Designer (1 year) j Performed the wind analysis and design for the steel structure framework and heavy machine supports. Projects included Cape Fear and May Flower Chemical Plants.

Virginia Polytechnic Institute:

Reeearch Assistant (1 year)

Performed research work on reinforced concrete project and taught reinforced concerte courses.

Tai-Ann Construction Corporation:

Assistant Engineer (2 years-Part-time)

Assisted in the stress analysis of the reinforced concrete and steel structures. Performed field

- I survey.

I e

G s

9 60