Text

=

=

[

Y13cOINIA ELI: critic Axn Powi:14Cox1wxy RIcnnoxu,VIItGINIA 232 0p1 November 2,1993 United States Nuclear Regulatory Commission Serial No.93-654 Attention: Document Control Desk NL&P/EJW Docket No.

50-339 Washington, D.C. 20555 License No.

NPF-7 i

?

Gentlemen:

VIRGINIA ELECTRIC AND POWER COMPANY i

NORTH ANNA POWER STATION UNIT 2 CYCLE 10 l

CORE OPER ATING LIMITS REPORT l

i Pursuant to Technical Specification 6.9.1.7.d, we are submitting the attached Core Operating Limits Report (COLR), Revision 1 for North Anna 2 Cycle 10 Pattern RE.

The previous version (Revision 0) of this document was revised prior to Unit 2 startup and was therefore not submitted to the NRC. The minimum measured flow rate for the reactor coolant system has been reduced to 275,300 gpm (from 284,000 gpm) as l

previously approved by the NRC on August 30,1993.

l Should you have any questions or require additional information, please contact us.

Very truly yours, l

\\

/

M. L. Bowling, Manager Nuclear Licensing and Programs Attachment cc:

United States Nuclear Regulatory Commission Region il 101 Marietta Street, N.W.

Suite 2900 Atlanta, GA 30323 Mr. R. D. McWhorter NRC Senior Resident inspector North Anna Power Station 08a022 00 k

9311090130 931102 E

1k(

{f PDR ADOCK 05000339

\\

P PDR l

-- :